www.ipdconverters.com
75
70
65
EFFICIENCY %
60
55
EFF. FRD2812
50 EFF. FRD2815)
45
40
35
10 20 30 40 50 60 70 80 90 10
Input
Voltage Range 5V, 12V, 24V, 28V, and 48V Nominal
See selection chart for specific input range. Efficiency vs. Load (48V Input)
Reflected Ripple 20% Iin Max. 70
60
55
EFFICIENCY %
Output 50
Line Regulation Vin Min. - Vin Max., Iout Rated ±0.15% Vout 40
EFF. FRD4812
EFF. FRD4815
Load Regulation Iout Min. - Iout Max., Vin Nom. ±0.15% Vout Iout Rated 35
Minimum Output Current 10 % lout Rated
30
Short Circuit Protection1 Continuous
25
10 20 30 40 50 60 70 80 90 10
LOAD %
General
Switching Frequency 20 kHz
Isolation
Input - Output 500 VDC Notes
Isolation Resistance - Input to Output 109 Ohms †
MTBF predictions may vary slightly from model to model.
Case Temperature
Operating Range -25 To +85°C
Storage Range -40 To +125°C Specifications typically at 25°C, normal line, and full load, unless otherwise stated.
Humidity Max, Non-Condensing 95%
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
Temperature Coefficient ±0.02%/°C
commercial wave-soldering equipment.
Vibration, 3 Axes, 5 Min Each 5 g, 10 - 55 Hz
Safety Consult Factory Safety: Agency approvals may vary from model to model. Please consult factory
Weight (Approx.) 2.2 oz for specific model information.
C-64
FRD SERIES - DUAL OUTPUT, 5 WATT
MODELS - (See the last page of this file for options.)
Vin Vin Range Iin Max.* Vout Iout Rated Ripple & Noise Efficiency
Model
(Volts) (Volts) (Amps) (Volts) (Amps) Pk-Pk (mV) Typ. **
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
MECHANICAL DRAWING
2.00"
(50.8mm)
0.18"(4.6mm) MIN.
1.40"
(35.6mm)
0.800"
(20.3mm) 3 4 5
2.00"
BOTTOM VIEW (50.8mm)
1 2
0
DIA 0.040"
(1.0mm)
0.40"
0
1.10" (10.2mm)
(27.9mm)
0.200"
(5.1mm)
C-65
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
Negative Logic N HAS, HBD, HBS, HES, LES, QBS, TTL “Low” Turns Module ON
QES, TES, TQD TTL “High” Turns Module OFF
Lucent Compatible Trim T HAS, HBD, HBS, HES, QBS, QES
Terminal Strip TS XWS, XWD, XWT
Trim 1 IAS, LES
Enable 2 IAD, IAS, LES, SMS
Trim and Enable 3 IAS, LES
Current Share 4 SMS
Headerless Y Encapsulated EWS, IWS, OWS
Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
C105