‘SUMMARY OF RATE ANALYSIS FOR ROADS FOR FY 078/077
CONTRACT RATE
TEMS DESCRIPTION TT [Rate (hrs)
“Section 2 |SITE CLEARANCE
(Gearing and grubbing of foreat ncuding uprooing, carving ana
seer no 2.01 _|48P0sing of vegetation grass, bush, sapling and rees of gith upto
[s0omm (measured ata height of im above the ground leve) lead
om
[e]irees & saping las an TS numbers per 100 sam sam 7a
p)Trees & saping ess than 15 numbers per 100 sq.m sam 31.98
[Clearing of grass, removing roas breaking sods, leveling We surface
ene oo re oer sam 2452
Feling and uprooting bamboo, Gearing te area, stacking of
nem No2.03 |namboo and dsposing of wastes to 1000m. (Volume ofthe excavated | cum | 2,481.93
should be measured.)
ling ees (he grth measured ata height oT Tm above pound
evel) including cutting of trunks and branches, removing the rots,
hem No 2.04 | stcking seneeable mates ond csposal of unserviceable
ja} above 300mm fo 600mm. 7m Tia
lb} above 600mm fo 900mm: no 3355.40
fel above 900mm to 1800mm. ‘no 8,776.80
fs) above 1800mm % 250mm no | 20,389.60
‘above 250mm io [67,068.00
snozos [Pressing and eveling ofthe constuction surface inuding cating
fem 70208 lang fling of small undulation, se ald
sn noz.oe [Exava o op Sol (Sub grade) and canying away Form
ee al sam 17087
Tem Z.07 | Spreading Shaping and lant compacting top <5 7 Spee. 2a 530)
ring Bridge. cuvert and other structures including stoping
tem 02.08.01. |the reusable materials and disposal of unusable materials within 50m.
Lead, (By Manuel Means)
a [By Manual Means,
fa Lime concrete cement concrete grade MIO and Below re
b. Cement Concrete Grade M15 & N20 ‘eum_| 2.00445
lc Pre- svessed Reinforced coment contre grade M20 above | cum | 4422.80
[By Mechanical Means.
fa. Cement Concrete Grade MTS & NZD eum] 27ST
ip Pre- stressed Reinforced coment cones grade MAD & above —[ eum | 3,269.92
Dismanting Bridge, culver and oer structures Including siocxpiing
‘te no:2.08,02 ( he reveable materials and disposal of unusable materials within 50m,
Lead
Diemanting Bickle Work
fa.Brick workin ime mortar eam 10786
b.Bick workin cement mora eum_| 1,938.90,
RSZOEEZ | Dismanting Stone Masonry
fa. Random rubble stone masonfy a Cement orlar cam] 758880
Hern 08__[Dismanting of Fiexble Pavements
[Dismanting of flexible pavements and disposal of emanted Material
lup to a lead of 1000 metres, stacking serviceable and unserviceable
Material separatl
oD By Manual Wears
(e] water bound Macadam materials ncuding solng/sub base om_| 2450
(tuminous msterals ‘eum_| 2456.40
T_——1By Mechanical Means
, [alsituminous course eam_| 1ST
SZ 10—|Dismanting of Cement Concrete Pavement
[Dismanting of cement concrete pavement by Mechanical means
lusing pneumatic to's, breaking to pieces not exceeding 0.02 cum in
jolume and stock png at designated locations and disposal of cum | 44atss
lismarted Materal upto lead of 1000 metres, stacking serviceable
~ OV \ remotes‘SUMMARY OF RATE ANALYSIS FOR ROADS FOR FY 076/077
CONTRACT RATE
TTEMS DESCRIPTION
Nit
Rate (Nes)
[Removing al type of Hume Pipes and Stacking within a lead of 60
including Earthwork and Dismantling of Wor
upto 600mm da
ore
i above 600mm to 600mm ia
994.98
I) above 900mm cia
af l3
7421.40,
fenro212
[Dismanting gabion works including stockpling the reusable materials
land disposal of reusable materials within 60m lead
1208.19
Section 4
[FENCING
[Gl Barbed wire fencing
[Gl Barbed wire fencing 12m high with ROC Post
1 ere a righ Cl Gated wre Fenn IN TET
IRCC posts 150mm*i60mm piaced every 3m center to center founded
in M15 grade cement concrete, 0.6m below ground level, every 15th
[post, last but one end post and corner post shall be strutted on both
sides and end post on end post one side ony and provided with 8
horizontal lines and 2 diagonals interwoven with horizontal wires,
lixed with Gl staples, tun buckles etc, complete a8 per Drawing and
[ei Barbed wire fencing 1.8m igh with RCC Post
1a eng Tarn Cl babe wre reno win TEAM
IRGC posts 150mm160mm placed every 3m center to center founded
in M15 grade cement concrete, 0.6m below ground level, every 16th
pos, last but one end post and corner post shall be struted on both
[sides and end post on end post one side only and provided wth 9
horizontal ines and 2 diagonals interwoven with horizontal wires,
lixed with Gl staples, turn buckles etc, complete a8 per Drawing and
It
4208.68
nical Snecificat
(Gr Barbed wire fencing 12m high
{Prov an fang thm igh Gt barbed wre Feng WAY TE
langle iron posts 4Omm x 40mm x 6mm placed every 3m center to
[center founded in M15 grade cement concrete, 0.6m below ground
level. every 15th post, last but one end post and comer post shall be
strutted on both sides and end post on end post one side only and
provided with 8 horizontal ines and 2 diagonals interwoven with
horizontal wires, fixed with Gl staples, tun buckles etc, complete as
52078
O: 4 Technical Snectficat
[Gi Barbed wire fencing 1 6m,
1S ae toang Tr High CT DADS WTS WERT WN ZA
[angle iron posts SOmm x SOmm x 6mm placed every 3m center to
[center founded in M15 grade cement concrete, 0.6m below ground
level, every 15th post, last but one end post and comer post shall be
|strtted on both sides and end post on end post one side only and
provided with 12 horizontal ines and 2 diagonals interwoven with
horizontal wires, fixed with GI staples, tum buckles etc., complete as
924.94
Drawing and Technical Snecical
[Pencing with welded steet wire fabnc rsmimx 60mm
ing and fing {-2m Tigh fencing with angle iow mae
‘50mm x 6mm placed every 3m center to center with 0.4m embedded
in M15 grade cement concrete, comer, end and every 10th post to
strutted. provided with welded steel wire fabric of 75mm x 50mm
Imesh or 75mm x 25mm mesh and fixed to iron posts by fat iron 50 x
|5mm and bolts ete. complete as per Drawing and Technical
cat
231252
[PIPE DRAIN, PIPE CULVERTS AND CONCRETE
Providing, jointing and laying HOP prpes with or without colar ef
|complete in place as per specification
fa) 10 mmv125mm outer diameter
TOTS
ye L
Checked by‘SUMMARY OF RATE ANALYSIS FOR ROADS FOR FY 076/077
CONTRACT RATE
SECTION ITEMS DESCRIPTION UNIT [Rate (Nrs)
[Providing and Laying Reinforced Cement Concrete Flush jointed Pipe
seem n0-7.02 or culverts Providing and Laying Reinforced cement concrete NP3
[Flush jointed pipe for culverts including fixing with cement mortar 1:2
{as pet Drawing and Technical Specifications.
I) 300mm dia (nt, m Fase
i). 450mm aa (nt) m. 6,355.98
i) 600mm da (Int) im 8,585.03
iv) 800mm da (int) m_|_— 16,128.56
Iv) 1200mm di (int) m_| 21,569.55
[Providing and Laying Reinforced Cement Concrete Pipe for culve
stem no.7.03 _|i86udng fixing colar Providing and Laying Reinforce cement
[concrete NPS Collar jointed pipe for culvert inctuding fixing colar
lwith cement mortar 1:2 as per Drawing and Technical Specifications
[300mm dia (int) m= EXZER
i 450mm oi (int) m. 6,776.36
it) 600mm dia (int im, 9,146.60
iv) 800mm cia (int) m_| 17,231.08
{120mm ia (Int) m_| 23,027.19
Section S__[EARTH WORKS:
Tem no,9.01 [Earthwork Excavation in Cutting,
[Roadway Excavation in All types of Sol
x [Manual means