Download as pdf
Download as pdf
You are on page 1of 14
Government of Nepal Madhyapur Thimi Municipality Office of Municipality Province No.3 Bhaktapur Analysis of Rates of Road Works _ | Madhyapur Thimi Municipality (According to Work Norms of Department of Roads and Agricultural Roads ) ‘SUMMARY OF RATE ANALYSIS FOR ROADS FOR FY 078/077 CONTRACT RATE TEMS DESCRIPTION TT [Rate (hrs) “Section 2 |SITE CLEARANCE (Gearing and grubbing of foreat ncuding uprooing, carving ana seer no 2.01 _|48P0sing of vegetation grass, bush, sapling and rees of gith upto [s0omm (measured ata height of im above the ground leve) lead om [e]irees & saping las an TS numbers per 100 sam sam 7a p)Trees & saping ess than 15 numbers per 100 sq.m sam 31.98 [Clearing of grass, removing roas breaking sods, leveling We surface ene oo re oer sam 2452 Feling and uprooting bamboo, Gearing te area, stacking of nem No2.03 |namboo and dsposing of wastes to 1000m. (Volume ofthe excavated | cum | 2,481.93 should be measured.) ling ees (he grth measured ata height oT Tm above pound evel) including cutting of trunks and branches, removing the rots, hem No 2.04 | stcking seneeable mates ond csposal of unserviceable ja} above 300mm fo 600mm. 7m Tia lb} above 600mm fo 900mm: no 3355.40 fel above 900mm to 1800mm. ‘no 8,776.80 fs) above 1800mm % 250mm no | 20,389.60 ‘above 250mm io [67,068.00 snozos [Pressing and eveling ofthe constuction surface inuding cating fem 70208 lang fling of small undulation, se ald sn noz.oe [Exava o op Sol (Sub grade) and canying away Form ee al sam 17087 Tem Z.07 | Spreading Shaping and lant compacting top <5 7 Spee. 2a 530) ring Bridge. cuvert and other structures including stoping tem 02.08.01. |the reusable materials and disposal of unusable materials within 50m. Lead, (By Manuel Means) a [By Manual Means, fa Lime concrete cement concrete grade MIO and Below re b. Cement Concrete Grade M15 & N20 ‘eum_| 2.00445 lc Pre- svessed Reinforced coment contre grade M20 above | cum | 4422.80 [By Mechanical Means. fa. Cement Concrete Grade MTS & NZD eum] 27ST ip Pre- stressed Reinforced coment cones grade MAD & above —[ eum | 3,269.92 Dismanting Bridge, culver and oer structures Including siocxpiing ‘te no:2.08,02 ( he reveable materials and disposal of unusable materials within 50m, Lead Diemanting Bickle Work fa.Brick workin ime mortar eam 10786 b.Bick workin cement mora eum_| 1,938.90, RSZOEEZ | Dismanting Stone Masonry fa. Random rubble stone masonfy a Cement orlar cam] 758880 Hern 08__[Dismanting of Fiexble Pavements [Dismanting of flexible pavements and disposal of emanted Material lup to a lead of 1000 metres, stacking serviceable and unserviceable Material separatl oD By Manual Wears (e] water bound Macadam materials ncuding solng/sub base om_| 2450 (tuminous msterals ‘eum_| 2456.40 T_——1By Mechanical Means , [alsituminous course eam_| 1ST SZ 10—|Dismanting of Cement Concrete Pavement [Dismanting of cement concrete pavement by Mechanical means lusing pneumatic to's, breaking to pieces not exceeding 0.02 cum in jolume and stock png at designated locations and disposal of cum | 44atss lismarted Materal upto lead of 1000 metres, stacking serviceable ~ OV \ remotes ‘SUMMARY OF RATE ANALYSIS FOR ROADS FOR FY 076/077 CONTRACT RATE TTEMS DESCRIPTION Nit Rate (Nes) [Removing al type of Hume Pipes and Stacking within a lead of 60 including Earthwork and Dismantling of Wor upto 600mm da ore i above 600mm to 600mm ia 994.98 I) above 900mm cia af l3 7421.40, fenro212 [Dismanting gabion works including stockpling the reusable materials land disposal of reusable materials within 60m lead 1208.19 Section 4 [FENCING [Gl Barbed wire fencing [Gl Barbed wire fencing 12m high with ROC Post 1 ere a righ Cl Gated wre Fenn IN TET IRCC posts 150mm*i60mm piaced every 3m center to center founded in M15 grade cement concrete, 0.6m below ground level, every 15th [post, last but one end post and corner post shall be strutted on both sides and end post on end post one side ony and provided with 8 horizontal lines and 2 diagonals interwoven with horizontal wires, lixed with Gl staples, tun buckles etc, complete a8 per Drawing and [ei Barbed wire fencing 1.8m igh with RCC Post 1a eng Tarn Cl babe wre reno win TEAM IRGC posts 150mm160mm placed every 3m center to center founded in M15 grade cement concrete, 0.6m below ground level, every 16th pos, last but one end post and corner post shall be struted on both [sides and end post on end post one side only and provided wth 9 horizontal ines and 2 diagonals interwoven with horizontal wires, lixed with Gl staples, turn buckles etc, complete a8 per Drawing and It 4208.68 nical Snecificat (Gr Barbed wire fencing 12m high {Prov an fang thm igh Gt barbed wre Feng WAY TE langle iron posts 4Omm x 40mm x 6mm placed every 3m center to [center founded in M15 grade cement concrete, 0.6m below ground level. every 15th post, last but one end post and comer post shall be strutted on both sides and end post on end post one side only and provided with 8 horizontal ines and 2 diagonals interwoven with horizontal wires, fixed with Gl staples, tun buckles etc, complete as 52078 O: 4 Technical Snectficat [Gi Barbed wire fencing 1 6m, 1S ae toang Tr High CT DADS WTS WERT WN ZA [angle iron posts SOmm x SOmm x 6mm placed every 3m center to [center founded in M15 grade cement concrete, 0.6m below ground level, every 15th post, last but one end post and comer post shall be |strtted on both sides and end post on end post one side only and provided with 12 horizontal ines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, tum buckles etc., complete as 924.94 Drawing and Technical Snecical [Pencing with welded steet wire fabnc rsmimx 60mm ing and fing {-2m Tigh fencing with angle iow mae ‘50mm x 6mm placed every 3m center to center with 0.4m embedded in M15 grade cement concrete, comer, end and every 10th post to strutted. provided with welded steel wire fabric of 75mm x 50mm Imesh or 75mm x 25mm mesh and fixed to iron posts by fat iron 50 x |5mm and bolts ete. complete as per Drawing and Technical cat 231252 [PIPE DRAIN, PIPE CULVERTS AND CONCRETE Providing, jointing and laying HOP prpes with or without colar ef |complete in place as per specification fa) 10 mmv125mm outer diameter TOTS ye L Checked by ‘SUMMARY OF RATE ANALYSIS FOR ROADS FOR FY 076/077 CONTRACT RATE SECTION ITEMS DESCRIPTION UNIT [Rate (Nrs) [Providing and Laying Reinforced Cement Concrete Flush jointed Pipe seem n0-7.02 or culverts Providing and Laying Reinforced cement concrete NP3 [Flush jointed pipe for culverts including fixing with cement mortar 1:2 {as pet Drawing and Technical Specifications. I) 300mm dia (nt, m Fase i). 450mm aa (nt) m. 6,355.98 i) 600mm da (Int) im 8,585.03 iv) 800mm da (int) m_|_— 16,128.56 Iv) 1200mm di (int) m_| 21,569.55 [Providing and Laying Reinforced Cement Concrete Pipe for culve stem no.7.03 _|i86udng fixing colar Providing and Laying Reinforce cement [concrete NPS Collar jointed pipe for culvert inctuding fixing colar lwith cement mortar 1:2 as per Drawing and Technical Specifications [300mm dia (int) m= EXZER i 450mm oi (int) m. 6,776.36 it) 600mm dia (int im, 9,146.60 iv) 800mm cia (int) m_| 17,231.08 {120mm ia (Int) m_| 23,027.19 Section S__[EARTH WORKS: Tem no,9.01 [Earthwork Excavation in Cutting, [Roadway Excavation in All types of Sol x [Manual means 0

You might also like