Scope of Accreditation-Nilesh Pandya Sir
Scope of Accreditation-Nilesh Pandya Sir
Proposed Scope
S. Product/Material of Range of (±)MU
Specific Test
Test method Testing/Limit of Test Performed at
No test Performed @Value
detection
Discipline: Electrical Group: Cables & wires
± 0.02 Permanent Facility
Elastomer Insulated Conductor Resistance IS 9968 (Part-1): 0.02 micro ohmto 1.1 ohm/km @
1
Cables Test 1988 ohm 3.112
ohm/km
Dimension ofArmour ± 0.01 Permanent Facility
Elastomer insulated wires for IS 9968 (Part-1):
2 0.01 mm to 300 mm mm @
cables Cables(Round, 1988
Formed, Strips) 1.394 mm
± 0.10 Permanent Facility
Elastomer Insulated Dimensions, Thickness IS 9968 (Part-1):
3 0.01 mm to 300 mm mm @
cables ofInsulation & Sheath 1988
0.82 mm
IS 9968 (Part-1): ±0.70 Permanent Facility
4 Elastomer insulated Elongation at break 1 mm to 610 mm mm @
cables ofInsulation & sheath 1988
46.4 mm
± 1.20 Permanent Facility
Elastomer Insulated IS 9968 (Part-1):
5 Flammability Test 0.02 mm to 600 mm mm @
Cables 1988
395.2 mm
Elastomer insulated High Voltage (Water IS 9968 (Part-1):
6 Qualitative @ PermanentFacility
cables ImmersionTest) 1988
Elastomer Insulated High Voltage Test- at IS 9968 (Part-1):
7 Qualitative @ PermanentFacility
Cables roomtemperature 1988
±0.38
Elastomer insulated IS 9968 (Part-1): mg/cm^2
8 Persulphate test 1 mg to 200 gm PermanentFacility
cables 1988 @ 3.8212
mg/cm^2
Elastomer Insulated IS 9968 (Part-1): ± 1.2 mm
9 Shrinkage Test 1 mm to 610 mm PermanentFacility
Cables 1988 @ 3.4 mm
± 1.68
Elastomer insulated Tensile Strength for IS 9968 (Part-2): N/mm^2
10 0.1 N/mmsq to PermanentFacility
cables Aluminium 2002 @ 171.564
24517 N/mmsq N/mm^2
Elastomer Insulated IS 9968 (Part-2):
11 Wrapping Test Qualitative @ PermanentFacility
Cables 2002
Elastomer insulted IS 9968 (Part-2):
12 Heat Shock Test Qualitative @ PermanentFacility
Cable 2002
High Voltage- at
13 Aerial Bunched Cables IS 14255: 1995 Qualitative @ Permanent Facility
for working voltages up room temperature
to and Including 1100
Volts
Aerial Bunched Cables ± 0.011 Permanent Facility
for working voltages up Water absorption mg/cm^2
14 to and Including 1100 IS 14255: 1995 1 mg/cm^2
test(gravimetric) @ 0.04632
Volts to 200 mg/cm^2
mg/cm^2
Aerial Bunched Cables ± 1.74 Permanent Facility
Tensile strength at
15 for working voltages up IS 14255: 1995 0.1 N/mmsq to N/mm^2
break ofinsulation &
to and Including 1100 @ 19.414
sheath 2452 N/mmsq
Volts N/mm^2
Aerial Bunched Cables ± 4.99 Permanent Facility
for working voltages up N/mm^2
16 Ageing in Air Oven IS 14255: 1995 0.1 N/mmsq to
to and Including 1100 @ 1.652
2452 N/mmsq N/mm^2
Volts
Aerial Bunched Cables Permanent Facility
17 for working voltages up Bending test IS 14255: 1995 Qualitative @
to and Including 1100
Volts
Aerial Bunched Cables ± 0.02 Permanent Facility
for working voltages up 0.02 OHM/KM to OHM/KM
18 Conductor Resistance IS 14255: 1995
to and Including 1100 39 OHM/KM @ 3.112
Volts OHM/KM
Aerial Bunched Cables ± 0.10 Permanent Facility
for working voltages up Dimensions, Thickness
19 IS 14255: 1995 0.01 MM to 300 MM MM @
to and Including 1100 ofInsulation & Sheath
0.82 MM
Volts
Aerial Bunched Cables ±0.70 Permanent Facility
for working voltages up Elongation at break
20 IS 14255: 1995 0.01 MM to 300 MM MM @
to and Including 1100 of Insulation & sheath
46.4 MM
Volts
Aerial Bunched Cables ± 0.55 Permanent Facility
for working voltages up Elongation Test on
21 IS 14255: 1995 1 MM to 610 MM MM @ 1.5
to and Including 1100 Messenger conductor
MM
Volts
Aerial Bunched Cables ± 0.60 Permanent Facility
for working voltages up MM @
22 Hot set test IS 14255: 1995 0.01 MM to 300 MM
to and Including 1100 10.376
Volts MM
Aerial Bunched Cables ± 17.86 Permanent Facility
Insulation Resistance 1 Mohm/Km to Mohm/km
23 for working voltages up IS 14255: 1995
to and Including 1100 Test 1000000 @ 613.076
Volts Mohm/Km Mohm/km
Aerial Bunched Cables Permanent Facility
± 1.2 mm
24 for working voltages up Shrinkage Test IS 14255: 1995 1 mm to 610 mm
to and Including 1100 @ 3.4 mm
Volts
Aerial Bunched Cables ± 1.68 Permanent Facility
for working voltages up N/mm^2
25 to and Including 1100 Tensile Strength for IS 14255: 1995 0.1 N/mmsq to
Aluminum @ 171.564
Volts 24517 N/mmsq
N/mm^2
Aerial Bunched Cables Permanent Facility
26 for working voltages up Wrapping Test IS 14255: 1995 Qualitative @
to and Including 1100
Volts
Aerial Bunched Cables Breaking Load Teston ± 0.02 Permanent Facility
27 for working voltages up Messenger IS 14255: 1995 0.1 N/mmsq to kN @
to and Including 1100 Conductor 24517 N/mmsq 1.282 kN
Volts
Wrapping Test for IS 10810(Part-3):
28 Aluminium wires Qualitative @ PermanentFacility
Aluminum 1984
29 Method for Test on Wrapping Test for IS 10810(Part-3): Qualitative @ Permanent Facility
Aluminum 1984
Cables
Method for Test on ± 0.91 Permanent Facility
Cables Resistivity test on IS 10810 (Part-42): 0.02 ohm-cm to 39 ohm-cm @
30
armoring material 1984 ohm-cm 1.4012
ohm-cm
Method for Test on ± 5.29 Permanent Facility
Cables IS 10810 (Part-37): N/mm^2
31 Tensile Strength 0.1 N/mmsq to
1984 @ 541.398
24517 N/mmsq N/mm^2
32 Armoring of cables Wrapping Test IS 3975: 1999 Qualitative @ Permanent Facility
Uniformity of zinc IS 10810 (Part 40): Permanent Facility
33 Method for Test on Qualitative @
coating 1984
Cables
±0.46 Permanent Facility
IS 10810 (Part 41): g/m^2 @
34 Method for Test on Mass of Zinc coating 1 g/m^2 to 200 g/m^2
1984 106.978
Cables g/m^2
±0.46 Permanent Facility
g/m^2 @
35 Armoring Mass of Zinc coating IS 3975: 1999 1 g/m^2 to 200 g/m^2
106.978
g/m^2
Uniformity of Zinc Permanent Facility
36 Armoring IS 3975: 1999 Qualitative @
coating
Uniformity of zinc IS 10810 (Part 40): Permanent Facility
37 Method for Test on Qualitative @
coating 1984
Cables
± 0.91 Permanent Facility
38 Armoring Material Resistivity test on IS 3975: 1999 0.02 ohm/cm39 ohm/cm @
armoring material ohm/cm 1.4012
ohm/cm
± 0.01 Permanent Facility
39 Armoring of cables Dimensions IS 3975: 1999 0.01 mm to 300 mm mm @
1.394 mm
IS 10810 (Part-36): ± 0.01 Permanent Facility
40 Method for Test on Dimensions 0.01 mm to 300 mm mm @
1984
Cables 1.394 mm
± 1.08 Permanent Facility
IS 10810 (Part 38): 1 count to 99999
41 Method for Test on Torsion test Turn @ 55
1984 count
Cables Turn
± 0.93 Permanent Facility
1 count to 99999
42 Armoring of cables Torsion test IS 3975: 1999 Count @
count
13 Count
IS 10810 (Part 39: Permanent Facility
43 Method for Test on Winding test Qualitative @
1984
Cables
± 0.11 Permanent Facility
Flammability Test on meter @
44 Bunched Cable IEEE 383: 2003 1 mm to 3050 mm
BunchedCables 0.432
meter
± 0.11 Permanent Facility
Flammability Test on IEC 60332 (Part 3- meter @
45 Bunched Cables 1 mm to 3050 mm
BunchedCables 21): 2000 0.432
meter
± 0.11 Permanent Facility
Flammability Test on IEC 60332 (Part 3- meter @
46 Bunched Cables 1 mm to 3050 mm
BunchedCables 22): 2018 0.432
meter
± 0.11 Permanent Facility
Flammability Test on IEC 60332 (Part 3- meter @
47 Bunched Cables 1 mm to 3050 mm
BunchedCables 23): 2018 0.432
meter
± 0.11 Permanent Facility
Flammability Test on IEC 60332 (Part 3- meter @
48 Bunched cables 1 mm to 3050 mm
BunchedCables 24): 2018 0.432
meter
Flammability Test on IS 10810 (Part-62): ± 0.11 m Permanent Facility
49 Bunched Cables 1 mm to 3050 mm
BunchedCables 1993 @ 0.432 m
Method for Test IS 10810 (Part-50): Permanent Facility
50 Bending test Qualitative @
on Cables 1984
51 Method for Test High Voltage (Water IS 10810 Part-45): Qualitative @ Permanent Facility
on Cables Immersion Test) 1984
Method for Test IS 10810 (Part-30): ± 0.60 Permanent Facility
52 on Cables Hot Set Test 0.01 mm to 300 mm mm @
1984
10.376 mm
Method for Test ± 17.86 Permanent Facility
on Cables Insulation Resistance IS 10810 (Part-43: 1 mohm/km to Mohm/km
53
test 1984 1000000 @ 613.076
Mohm/km Mohm/km
Method for Test ±0.27 Permanent Facility
on Cables IS 10810 (Part-10): mg/cm^2
54 Loss of Mass Test 1 mg/cm^2 to 200
1984 @ 3.316
mg/cm^2 mg/cm^2
± 1.2 mm Permanent Facility
55 Cable Shrinkage Test BS EN 60811: 2012 0.01 mm to 300 mm
@ 3.4 mm
± 0.60 Permanent Facility
Tests on Insulation: IS 10810 (Part 30):
56 Method for Test 0.01 mm to 300 mm mm @
Hot set test 1984
on Cables 10.376 mm
Cable and Accessories: IEC 60502 (Part 2): ± 0.60 Permanent Facility
57 Hot Test Test 0.01 mm to 300 mm mm @
HT Elastomer cable 2014
10.376 mm
Cable and Accessories: Dimension, Thickness IEC 60502 (Part-2): ± 0.10 Permanent Facility
58 HT Elastomer cable ofinsulation & Sheath 0.01 mm to 300 mm mm @
single/ threecore 2014
0.82 mm
Cable and Accessories: ,IEC 60502 (Part-2): Permanent Facility
59 HT Elastomer cable Cold Bend Test Qualitative @
single/ threecore 2014
Cable and Accessories: IEC 60502 (Part-1):
60 HT Elastomer cable Cold Bend Test Qualitative @ Permanent Facility
single/ threecore 2004
Cable and Accessories: IEC 60502 (Part-1): ± 0.10
61 HT Elastomer cable Dimension, Thickness 0.01 mm to 300 mm mm @ PermanentFacility
ofinsulation & Sheath 2004
single/ threecore 0.82 mm
Cable and Accessories: IEC 60502 (Part-2): ± 1.11 %
62 HT Elastomer cable Hot Deformation test 0.5 mm to 180 mm PermanentFacility
single/ threecore 2014 @ 54.2 %
±0.27 mg
Cable and Accessories:
IEC 60502 (Part-1): /cm^2 @
63 HT Elastomer cable Loss of Mass Test 1 mg to 200 gm PermanentFacility
2012 3.316 mg
single/ threecore
/cm^2
±0.27
Cable and Accessories: IEC 60502 (Part-2): mg/cm^2
64 HT Elastomer cable Loss of Mass Test 1 mg to 200 gm PermanentFacility
2014 @ 3.316
single/ threecore
mg/cm^2
Cable and Accessories: IEC 60502 (Part-1): ± 1.2 mm
65 HT Elastomer cable Shrinkage Test 1 mm to 610 mm PermanentFacility
single/ threecore 2012 @ 3.4 mm
Cable and Accessories: ± 4.20
IEC 60502(Part-1):
66 HT Elastomer cable Thermal Stability Test 0.01 sec to 99 hour min @ 93.4 PermanentFacility
2012
single/ threecore min
Cable and Accessories: IEC 60502 (Part-2): ± 4.20
67 HT Elastomer cable Thermal Stability Test 0.01 sec to 99 hour min @ 93.4 PermanentFacility
single/ threecore 2014 min
± 4.99
Cable for motor N/mm^2
68 Ageing in Air Oven IS 2465: 1984 0.1 N/mmto 25 PermanentFacility
Vehicle @ 1.652
N/mm N/mm^2
±0.27
Cable for Motor mg/cm^2
69 Loss of Mass Test IS 2465: 1984 1 mg to 200 gm PermanentFacility
Vehicle @ 3.316
Mg/cm^2
±0.38
Cable for Motor g/m^2 @
70 Persulphate Test IS 2465: 1984 1 mg to 200 gm PermanentFacility
vehicle 3.8212
g/m^2
± 4.99
cable for Motor Conductor Resistance 0.02 micro ohmto 1.1 ohm/km @
71 IS 2465: 1984 PermanentFacility
Vehicles Test ohm 7.676
ohm/km
Bleeding and blooming IS 10810 (Part-19): Qualitative :Visual
72 Method for @ Permanent Facility
test 1984 Examination
Test on
Cables
IEC 60811 (Part-504):
73 Cables Cold Bend Test Qualitative @ PermanentFacility
2012
IEC 60811 (Part-506):
74 Cables Cold Impact Test Qualitative @ PermanentFacility
2012
75 Cables Cold Impact Test IEC 60811 (Part-506): Qualitative @ PermanentFacility
2012
IS 10810 (Part-21):
76 Method for Cold Impact Test Qualitative @ Permanent Facility
1984
Test on
Cables
Determination of the ±1.43
amountof halogen and IS 10810 (Part-59): Mg/gm
77 Method for gas evolution 1 mg/gm to 200 Permanent Facility
Corrosive & halogen 1988 @ 142.657
Test on mg/gm
Cables acid gas Mg/gm
± 4.31
Flame retardant test, IS 10810 (Part-61):
78 Method for test on 1 mm to 3050 mm mm @ 600 Permanent
Swedishchimney test 1988
Cables mm Facility
± 1.11 %
79 Cables Hot Deformation Test IEC 60811: 2012 0.5 mm to 180 mm PermanentFacility
@ 54.2 %
± 1.11 %
80 Cables Hot Deformation Test BS EN 60811: 2012 0.5 mm to 180 mm PermanentFacility
@ 54.2 %
±0.27
mg/cm^2
81 Cables loss of Mass Test IEC 60811: 2012 1 mg to 200 gm PermanentFacility
@ 3.316
mg/cm^2
method to determine the 35 % to 75 % ± 0.88 %
82 minimum concentration of Oxygen index test ASTM D 2863: 2013 Permanent
oxygen in an @ 30.42 %
Facility
oxygen/nitrogen mixture
that will support a flaming
burn in a plastic specimen
Oxygen index test,
IS 10810 (Part-58): ± 0.88 %
83 Method for Test Temperature indextest 35 % to 75 % Permanent
1998 @ 30.42 %
on cables Facility
Oxygen index test, IS 10810 (Part-64): ± 11.91 Permanent Facility
84 Method for Test Temperature indextest 25 Deg C to 400 deg C °C @
2003
on cables 374.4 °C
Method for Test ±0.38 Permanent Facility
on cables IS 10810 (Part-4): g/m^2 @
85 Persulphate Test 1 g/m^2 to 200
1984 3.8212
g/m^2 g/m^2
Method for Test IS 10810 (Part-12): ± 1.2 % Permanent Facility
86 Shrinkage Test 1 mm to 610 mm
on cables 1984 @ 3.4 %
± 1.2 mm Permanent Facility
87 Cables Shrinkage Test IEC 60811: 2012 1 mm to 610 mm
@ 3.4 mm
Test Method for Density of
Smoke from the Burning or
± 2.18 % Permanent Facility
88 Decomposition of Plastics Smoke density test ASTM D 2843: 2010 1 % to 100 % @ 43.734
%
Test Method for Density of ± 2.18 %
Smoke from the Burning or
Permanent Facility
89 Decomposition of Plastics Smoke density test IS 13360: 2001 1 % to 100 % @ 43.734
%
method to determine the ± 11.91 Permanent Facility
minimum concentration of 0.1 Deg C to 100 deg
90 oxygen in an oxygen/nitrogen Temperature index test ASTM D 2863: 2013 °C @
mixture that will support a C
flaming burn in a plastic
373.4 °C
specimen
± 1.68 Permanent Facility
Tensile strength for IS 10810 (Part-2): N/mm^2
91 Method for Tests 0.1 N/mmsq to
Aluminum 1984 @ 171.564
on Cables 24517 N/mmsq N/mm^2
IS 10810 (Part-60): ± 4.20 Permanent Facility
92 Method for Tests Thermal Stability Test 0.01 sec to 99 hour min @ 93.4
1988 min
on Cables
± 4.20
93 Cables Thermal Stability Test BS EN 60811: 2012 0.01 sec to 99 hour min @ 93.4 PermanentFacility
min
± 2.45
Cables for motor mm @
94 Annealing Test IS 2465: 1984 1 mm to 610 mm PermanentFacility
vehicle
34.7 mm
± 0.10
Cables for motor Dimensions, Thickness
95 IS 2465: 1984 0.01 mm to 300 mm mm @ PermanentFacility
vehicle ofInsulation & sheath
0.82 mm
Cables for motor Elongation at break ±0.70
96 IS 2465: 1984 1 mm to 610 mm mm @ PermanentFacility
vehicle ofInsulation & sheath
46.4 mm
Cables for Motor
97 Heat Shock IS 2465: 1984 Qualitative @ PermanentFacility
Vehicle
Cables for Motor ± 1.11 %
98 Hot Deformation Test IS 2465: 1984 0.5 mm to 180 mm PermanentFacility
Vehicle @ 54.2 %
Cables for motor High Voltage- at
99 IS 2465: 1984 Qualitative @ PermanentFacility
vehicles roomtemperature
± 1.74
Cables for motor Tensile Strength at
100 IS 2465: 1984 0.1 N/mmto 25 N/mm^2 PermanentFacility
break ofInsulation &
vehicles @ 19.414
sheath N/mm N/mm^2
101 Cables for Motor Shrinkage Test IS 2465: 1984 1 mm to 610 mm ± 1.2 mm PermanentFacility
Vehile @ 3.4 mm
Conductors for Permanent Facility
± 2.45
Insulated Electric
102 Annealing Test IS 8130 : 2013 1 mm to 610 mm mm @
Cables and Flexible
Cords 34.7 mm
Conductors for ±0.38 Permanent Facility
Insulated Electric Pursulphate test g/m^2 @
103 IS 8130: 2013 1 g/m^2 to 200
Cables and Flexible (Tinned Copper only) 3.8212
Cords g/m^2 g/m^2
Conductors for ± 4.99 Permanent Facility
Insulated Electric 0.02 ohm/km to 39 ohm/km @
104 Resistance Test IS 8130: 2013
Cables and Flexible ohm/km 7.676
Cords ohm/km
Conductors for ± 1.68 Permanent Facility
Insulated Electric N/mm^2
105 Tensile Test IS 8130 : 2013 0.1 N/mmsq to
Cables and Flexible @ 171.564
Cords 24517 N/mmsq N/mm^2
Conductors for Permanent Facility
Insulated Electric Qualitative :visual
106 Wrapping Test IS 8130 : 2013 @
Cables and Flexible Examination
Cords
IS 10810 (Part-1): ± 2.45 Permanent Facility
107 Method for tests on Annealing Test 1 mm to 610 mm mm @
1984
cables 34.7 mm
± 4.99 Permanent Facility
Cross Linked IS 7098 (Part-3): N/mm^2
108 Polyethylene Insulated, Aging in Air Oven 0.1 N/mmto 25
1993 @ 1.652
PVC Sheathed cables N/mm N/mm^2
± 4.99 Permanent Facility
Cross Linked
IS 7098 (Part-2): N/mm^2
109 Polyethylene Insulated, Aging in Air Oven 0.1 N/mmto 25
2011 @ 1.652
PVC Sheathed cables N/mm N/mm^2
Cross Linked IS 7098 (Part-1): Permanent Facility
110 Polyethylene Insulated, Cold Bend Test Qualitative @
PVC Sheathed cables 1988
± 0.02 Permanent Facility
Cross Linked IS 7098 (Part-1): 0.02 ohm/km to 39 ohm/km @
111 Polyethylene Insulated, Conductor Resistance
1988 ohm/km 3.112
PVC Sheathed cables
ohm/km
Cross Linked ± 0.10 Permanent Facility
Dimensions, Thickness IS 7098 (Part-1):
112 Polyethylene Insulated, 0.01 mm to 300 mm mm @
of Insulation & Sheath 1988
PVC Sheathed cables 0.82 mm
Cross Linked Dimensions, Thickness IS 7098 (Part-2): ± 0.10 Permanent Facility
113 Polyethylene Insulated, 0.01 mm to 300 mm mm @
of Insulation & Sheath 2011
PVC Sheathed cables 0.82 mm
Cross Linked Dimensions, Thickness IS 7098 (Part-3): ± 0.10 Permanent Facility
114 Polyethylene Insulated, 0.01 mm to 300 mm mm @
ofInsulation & Sheath 1993
PVC Sheathed cables 0.82 mm
Cross Linked IS 7098 (Part-1): ±0.70 Permanent Facility
Elongation at break mm @
115 Polyethylene Insulated, 1 mm to 610 mm
of Insulation & Sheath 1988
PVC Sheathed cables 46.4 mm
Cross Linked IS 7098 (Part-1):
116 Polyethylene Insulated, Heat Shock Test Qualitative @ Permanent Facility
PVC Sheathed cables 1988
Cross Linked IS 7098 (Part-3):
117 Polyethylene Insulated, Heat Shock Test Qualitative @ PermanentFacility
PVC Sheathed cables 1993
Cross Linked IS 7098 (Part-2):
118 Polyethylene Insulated, Heat Shock Test Qualitative @ PermanentFacility
PVC Sheathed cables 2011
Cross Linked
± 1.11 %
119 Polyethylene Insulated, Hot Deformation Test IS 7098 (part-2): 2011 0.5 mm to 180 mm PermanentFacility
PVC Sheathed cables @ 54.2 %
Cross Linked IS 7098 (Part-3): ± 1.11 %
120 Polyethylene Insulated, Hot Deformation Test 0.5 MM to 180 MM PermanentFacility
PVC Sheathed cables 1993 @ 54.2 %
Cross Linked IS 7098 (Part-1): ± 1.11 %
121 Polyethylene Insulated, Hot Deformation test 0.5 % to 180 % Permanent Facility
PVC Sheathed cables 1988 @ 54.2 %
± 17.86
Cross Linked
Insulation Resistance IS 7098 (Part-2): 1 Mohm/Km to M ohm/km
122 Polyethylene Insulated, PermanentFacility
Test 2011 1000000 @ 613.076
PVC Sheathed cables
Mohm/Km M ohm/km
±0.27
Cross Linked IS 7098 (Part-2): mg/cm^2
123 Polyethylene Insulated, Loss of Mass Test 1 mg to 200 gm PermanentFacility
2011 @ 3.316
PVC Sheathed cables
mg/cm^2
±0.27
Cross Linked
IS 7098 (Part-2): mg/cm^2
124 Polyethylene Insulated, Loss of Mass Test 1 mg to 200 gm PermanentFacility
2011 @ 3.316
PVC Sheathed cables
mg/cm^2
±0.27
Cross Linked IS 7098 (Part-3):
125 Polyethylene Insulated, Loss of Mass Test 1 MG to 200 GM mg/cm^2 PermanentFacility
1993 @ 3.316
PVC Sheathed cables
mg/cm^2
±0.27 mg
Cross Linked
IS 7098 (Part-1): 1 mg /cm^2 @
126 Polyethylene Insulated, Loss of Mass Test Permanent Facility
1988 /cm^2 to 200 mg 3.316 mg
PVC Sheathed cables
/cm^2 /cm^2
± 0.91
Cross Linked
Resistivity Test on IS 7098 (Part-2): 0.02 micro ohmto 1 ohm/cm @
127 Polyethylene Insulated, PermanentFacility
armoringmaterial 2011 ohm 1.4012
PVC Sheathed cables
ohm/cm
Cross Linked IS 7098 (Part-2): ± 1.2 mm
128 Polyethylene Insulated, Shrinkage Test 1 ,mm to 610 mm PermanentFacility
PVC Sheathed cables 2011 @ 3.4 mm
Cross Linked IS 7098 (Part-3): ± 1.2 mm
129 Polyethylene Insulated, Shrinkage Test 1 mm to 610 mm PermanentFacility
PVC Sheathed cables 1993 @ 3.4 mm
Cross Linked Permanent Facility
IS 7098 (Part-1): ± 1.2 mm
130 Polyethylene Insulated, Shrinkage Test 1 mm to 610 mm
PVC Sheathed cables 1988 @ 3.4 mm
613 Method of chemical Copper Purity Test IS 440: 1964 Qualitative @ PermanentFacility
analysis of copper
±0.27
Paper insulated lead mg/cm^2
614 Loss of Mass Test IS 692: 1994 1 mg to 200 gm PermanentFacility
sheathed cable @ 3.316
mg/cm^2
± 4.99
Paper Insulated Lead N/mm^2
615 Ageing in Air Oven IS 692: 1994 0.1 N/mmto 25 PermanentFacility
sheathed cables @ 1.652
N/mm N/mm^2
± 2.45
616 Paper Insulated lead Annealing Test IS 692: 1994 1 mm to 610 mm mm @ PermanentFacility
sheathed cables
34.7 mm
Armour wires for
Paper Insulated Lead
617 Cables(Round, IS 692: 1994 Qualitative @ PermanentFacility
Sheathed Cables
Formed, Strips)
± 0.02
Paper Insulated lead Conductor Resistance 0.02 micro ohmto 1.1 ohm/km @
618 IS 692: 1994 PermanentFacility
sheathed cables Test ohm 3.112
ohm/km
± 0.10
Paper Insulated Lead Dimensions, thickness
619 IS 692: 1994 0.01 mm to 300 mm mm @ PermanentFacility
Sheathed Cables ofinsulation & Sheath
0.82 mm
±0.70
620 Paper insulated lead Elongation at break IS 692: 1994 1 mm to 610 mm mm @ PermanentFacility
sheathed cables
46.4 mm
± 1.20
Paper Insulated lead
621 Flammability Test IS 692: 1994 0.02 mm to 600 mm mm @ PermanentFacility
sheathed cables
395.2 mm
Paper Insulated lead
622 Heat Shock test IS 692: 1994 Qualitative @ PermanentFacility
sheathed cables
Paper Insulated lead ± 1.11 %
623 Hot Deformation test IS 692: 1994 0.5 mm to 180 mm PermanentFacility
sheathed cables @ 54.2 %
± 17.86
624 Paper Insulated lead Insulation resistance IS 692: 1994 1 Mohm/Km to ohm/cm @ PermanentFacility
sheathed cables test 1000000 613.076
Mohm/Km ohm/cm
625 Paper Insulated lead Shrinkage Test IS 692: 1994 1 mm to 610 mm ± 1.2 mm PermanentFacility
sheathed cables @ 3.4 mm
± 1.74
Paper insulated lead N/mm^2
626 Tensile Strength IS 692: 1994 0.1 N/mmto 25 PermanentFacility
sheathed cables @ 19.414
N/mm N/mm^2
Paper Insulated Lead Uniformity of Zinc
627 IS 692: 1994 Qualitative @ PermanentFacility
Sheathed Cables coating
Paper Insulated lead
628 Wrapping Test IS 692: 1994 Qualitative @ PermanentFacility
sheathed cables
± 1.68
Paper insulated led Tensile strength at N/mm^2
629 IS 692: 1994 0.1 N/mmsq to PermanentFacility
sheathed cables break @ 171.
24517 N/mmsq N/mm^2
Polymeric insulated and
sheathed electric cable ±0.70
630 for workingvoltage up Elongation at break AS/NZS 5000.1: 2005 1 mm to 610 mm mm @ PermanentFacility
to and including 46.4 mm
0.6/1(1.2)kV
Polymeric insulated and ± 1.74
sheathed electric cable
Tensile strength at N/mm^2
631 for workingvoltage up AS/NZS 5000.1: 2005 0.1 N/mmto 25 PermanentFacility
break @ 19.414
to and including N/mm
0.6/1(1.2)kV N/mm^2
Polymeric insulated and ± 1.68
sheathed electric cable
632 Tensile test on AS/NZS 5000.1: 2005 0.1 N/mmsq to N/mm^2 PermanentFacility
for workingvoltage up
aluminium @ 171.564
to and including 24517 N/mmsq N/mm^2
0.6/1(1.2)kV
Polymeric insulated and
sheathed electric cables ± 2.45
633 forworking voltages up Annealing Test AS/NZS 1125: 2001 1 mm to 610 mm mm @ PermanentFacility
to and including 34.7 mm
0.6/1(1.2) kV
Polymeric insulated and
sheathed electric cables ± 2.45
634 forworking voltages up Annealing Test AS/NZS 5000.1: 2005 1 mm to 610 mm mm @ PermanentFacility
to and including 34.7 mm
0.6/1(1.2)kV
Polymeric insulated and
sheathed electric cables ± 2.45
635 forworking voltages up Annealing Test AS/NZS 5000.1: 2005 1 mm to 610 mm mm @ PermanentFacility
to and including 34.7 mm
0.6/1(1.2)kV
Polymeric insulated and
sheathed electric cables ± 2.45
636 forworking voltages Annealing Test AS/NZS 1660.1: 1998 1 mm to 610 mm mm @ PermanentFacility
upto and including 34.7 mm
0.6/1(1.2)kV
±0.27
Power Cable with
mg/cm^2
637 extruded insulation & Loss of Mass Test IEC 60840: 2011 1 mg to 200 gm PermanentFacility
@ 3.316
their accessories
mg/cm^2
Power cable with
extruded insulation and ± 2.45
638 their accessoriesfor Annealing Test IEC 60228: 2004 1 mm to 610 mm mm @ PermanentFacility
rated voltage from 1 34.7 mm
kV upto 30kV
± 4.99
Power cable with
N/mm^2
639 extruded insulation and Ageing in Air Oven IEC 60840: 2011 0.1 N/mmto 25 PermanentFacility
@ 1.652
their accessories N/mm N/mm^2
CARBON
Method for Test on 10.12mg/g
CONTENT TEST IS:10810 (Part 32):
640 Cables 1 mg/g to 200 mg/g @ 134.37 Permanent
FOR 1984
POLYETHYLENE mg/g Facility
Power cable with ±0.70
641 extruded insulation and Elongation at break IEC 60840: 2011 1 mm to 610 mm mm @ PermanentFacility
their accessories 46.4 mm
Power cable with ± 1.2 mm
642 extruded insulation and Shrinkage Test IEC 60840: 2011 1 mm to 610 mm PermanentFacility
their accessories @ 3.4 mm
Power cables with ± 0.10
Dimensions, Thickness mm @
643 extruded insulation & IEC 60840: 2011 0.01 mm to 300 mm PermanentFacility
ofInsulation & Sheath
their accessories 0.82 mm
±10.12
Power cables with IEC 60502 (Part 1) :
Carbon black content mg/g @
644 extruded insulation and 1 deg C to 900 deg c PermanentFacility
test 2012 134.37
their accessories
mg/g
Power cables with Armour wires for
645 extruded insulation and Cables(Round, IEC 60840: 2011 Qualitative @ PermanentFacility
their accessories Formed, Strips)
Power cables with ± 10.12
Carbon black content IEC 60502 (Part 2) : mg/g @
646 extruded insulation and 1 deg C to 900 deg c PermanentFacility
test 2012 134.37
their accessories
mg/g
± 10.12
Power cables with
Carbon black content mg/g @
647 extruded insulation and IEC 60840: 2011 1 deg c to 900 deg c PermanentFacility
test 134.37
their accessories
mg/g
Power cables with
648 extruded insulation and Cold Bend Test IEC 60840: 2011 Qualitative @ PermanentFacility
their accessories
Power cables with
649 extruded insulation and Cold Impact Test IEC 60840: 2011 Qualitative @ PermanentFacility
their accessories
Power cables with
650 extruded insulation and Heat Shock Test IEC 60840: 2011 Qualitative @ PermanentFacility
their accessories
Power cables with ± 0.60
651 extruded insulation and Hot set test IEC 60840: 2011 0.01 mm to 300 mm mm @ PermanentFacility
their accessories 10.376 mm
± 1.74
Power cables with
Tensile strength at N/mm^2
652 extruded insulation and IEC 60840: 2011 0.1 N/mmto 25 PermanentFacility
break @ 19.414
their accessories N/mm N/mm^2
± 1.74
PVC Insulated Cables Tensile strength at
653 for rated voltage up to SS 358-1: 2011 0.1 N/mmto 25 N/mm^2 PermanentFacility
break @ 19.414
and including450/750V N/mm N/mm^2
PVC Insulated Cables ±0.70
654 for rated voltage upto Elongation at break SS 358-1: 2011 1 mm to 610 mm mm @ PermanentFacility
and including450/750V 46.4 mm
IEC/BS EN 60903: ±0.70
Safety test items,
655 Elongation 1 mm to 610 mm mm @ PermanentFacility
rubber hand gloves 2014
46.4 mm
± 1.74
Safety test items, IEC/BS EN 60903: N/mm^2
656 Tensile Strength 0.1 N/mmto 25 PermanentFacility
rubber hand gloves 2014 @ 19.414
N/mm N/mm^2
± 1.74
Safety test items, N/mm^2@
657 Tensile strength IS 4770: 1991 0.1 N/mmto 25 PermanentFacility
rubber hand gloves 19.414
N/mm N/mm^2
Single Conductor with ± 2.45
658 Annealing Test UL 758: 2000 1 mm to 610 mm mm @ PermanentFacility
Extruded Insulation
34.7 mm
± 2.45
Single conductor with
659 Annealing Test UL 1007: 2012 1 mm to 610 mm mm @ PermanentFacility
extruded insulation
34.7 mm
± 2.45
Single conductor with mm @
660 Annealing Test UL 1581: 2001 1 mm to 610 mm PermanentFacility
extruded insulation
34.7 mm
± 2.45
Single conductor with mm @
661 Annealing Test UL 2556: 2014 1 mm to 610 mm PermanentFacility
extruded insulation
34.7 mm
± 2.45
662 Single Conductor with Annealing Test UL 3344: 2012 1 mm to 610 mm mm @ PermanentFacility
extruded insulation
34.7 mm
Single core non-
sheathed cables with ± 1.74
halogen free cross Tensile Strength at N/mm^2
663 BS 50525-3: 2011 0.1 N/mmto 25 PermanentFacility
linked insulation of break @ 19.414
rated voltage up to and N/mm N/mm^2
including450/750 V
Single core non-
sheathed cables with ±0.70
664 halogen free Elongation at break BS 50524-3: 2011 1 mm to 610 mm mm @ PermanentFacility
crosslinked insulation
46.4 mm
of rated voltage upto
and including450/750V
Single core non-
sheathed cables with ± 1.74
halogen free Tensile Strength at N/mm^2
665 BS 50525-3: 2011 0.1 N/mmto 25 PermanentFacility
crosslinked insulation break @ 19.414
of rated voltage upto N/mm N/mm^2
and including450/750V
Single core PVC ± 1.74
insulated flexible cable Tensile strength at N/mm^2
666 for workingvoltages up BS 6231: 1998 0.1 N/mmto 25 PermanentFacility
break @ 19.414
to and including N/mm N/mm^2
600/1000 V
Single core PVC
insulated flexible cables ±0.70
667 for rated voltageup to Elongation at break BS 6231: 1998 1 mm to 610 mm mm @ PermanentFacility
and including 600/1000 46.4 mm
V
± 0.02
Thermosetting insulated
Conductor Resistance 0.02 micro ohmto 1.1 ohm/km @
668 & thermoplastic BS 7211: 2012 PermanentFacility
Test ohm 3.112
sheathed cables
ohm/km
Thermosetting insulated ± 0.10
Dimensions, Thickness
669 & Thermoplastic BS 7211: 2012 0.01 mm to 300 mm mm @ PermanentFacility
ofInsulation & Sheath
sheathed cables 0.82 mm
Thermosetting insulated ±0.70
670 & Thermoplastic Elongation at break BS 7211: 2012 1 mm to 610 mm mm @ PermanentFacility
sheathed cables 46.4 mm
± 4.99
Thermosetting insulated
N/mm^2
671 and thermoplastic Aging in Air Oven BS 7211: 2012 0.1 N/mmto 25 PermanentFacility
@ 1.652
sheathedcables N/mm N/mm^2
Thermosetting insulated Armour wires for
672 and thermoplastic Cables(Round, BS 7211: 2012 Qualitative @ PermanentFacility
sheathedcables Formed, Strips)
Thermosetting insulated
673 and thermoplastic Cold Bend Test BS 7211: 2012 Qualitative @ PermanentFacility
sheathedcables
Determination of the ±1.43
Thermosetting insulated amountof halogen acid mg/gm @
674 and thermoplastic gas evolution - BS 7211: 2012 1 mg to 200 gm 142.657 PermanentFacility
sheathedcables Corrosive & halogen mg/gm
acid gas
Thermosetting insulated ± 1.20
675 and thermoplastic Flammability test BS 7211: 2012 0.02 mm to 600 mm mm @ PermanentFacility
sheathedcables 395.2 mm
Thermosetting insulated ± 1.20
676 and thermoplastic Flammability test IS 7211: 2012 1 mm to 610 mm mm @ PermanentFacility
sheathedcables 395.2 mm
Thermosetting insulated
677 and thermoplastic Heat Shock Test BS 7211: 2012 Qualitative @ PermanentFacility
sheathedcables
Thermosetting insulated ± 0.60
678 and thermoplastic Hot set test BS 7211: 2012 0.01 mm to 300 mm mm @ PermanentFacility
sheathedcables 10.376 mm
± 17.86
Thermosetting insulated 1 M ohmto
Insulation resistance M ohm/km
679 and thermoplastic BS 7211: 2012 PermanentFacility
test 1000000 M ohm @ 613.076
sheathedcables
M ohm/km
Thermosetting insulated
680 Water absorption BS 7211: 2012 Qualitative @ PermanentFacility
and thermoplastic
test(gravimetric)
sheathedcables
Thermosetting insulated
and thermoplastic ±0.70
681 sheathedcables for Elongation at break BS 7211: 2012 1 mm to 610 mm mm @ PermanentFacility
voltage upto and 46.4 mm
including 450/750V
Thermosetting insulated
682 and thermoplastic Cold Impact Test BS 7211: 2012 Qualitative @ PermanentFacility
sheathed cable
Thermosetting insulated ± 1.68
armored cable for
Tensile on armor N/mm^2
683 working voltageup to BS 5467: 2016 0.1 N/mmsq to PermanentFacility
aluminiumwire @ 171.564
and including 600/100 24517 N/mmsq
V N/mm^2
Thermosetting insulated ± 1.74
armored cable for
Tensile strength at N/mm^2
684 working voltageup to BS 5467: 2016 0.1 N/mmto 25 PermanentFacility
break B @ 19.414
and including 600/100 N/mm
V N/mm^2
± 4.99
Thermosetting insulated N/mm^2
685 Aging in Air Oven BS 6724: 2016 0.1 N/mmto 25 PermanentFacility
armored cables @ 1.652
N/mm N/mm^2
±0.70
Thermosetting insulated
686 Elongation at break BS 6724: 2016 1 mm to 610 mm mm @ PermanentFacility
armoured cables
46.4 mm
Thermosetting insulated
687 Heat Shock Test BS 6724: 2016 Qualitative @ PermanentFacility
armoured cables
± 17.86
Thermosetting insulated Insulation resistance 1 Mohm/Km to M ohm/km
688 BS 6724: 2016 PermanentFacility
armoured cables test 1000000 @ 613.076
Mohm/Km M ohm/km
± 1.74
Thermosetting insulated Tensile Strength at N/mm^2
689 BS 6724: 2016 0.1 N/mmto 25 PermanentFacility
armoured cables break @ 19.414
N/mm N/mm^2
± 4.99
Thermosetting insulated
N/mm^2
690 armoured fire Ageing in Air Oven BS 7846: 2015 0.1 N/mmto 25 PermanentFacility
@ 1.652
resistance cables N/mm N/mm^2
Thermosetting insulated ±0.70
691 armoured fire Elongation at break BS 7846: 2015 1 mm to 610 mm mm @ PermanentFacility
resistance cables 46.4 mm
Thermosetting insulated
692 armoured fire Heat Shock Test BS 7846: 2015 Qualitative @ PermanentFacility
resistance cables
Thermosetting insulated ± 17.86
Insulation resistance 1 Mohm/Km to ohm-cm
693 armoured fire BS 7846: 2015 PermanentFacility
test 1000000 @ 613.076
resistance cables
Mohm/Km ohm-cm
± 1.74
Thermosetting insulated
Tensile strength at N/MM^2
694 armoured fire BS 7846: 2015 0.1 N/mmto 25 PermanentFacility
break @ 19.414
resistance cables N/mm N/mm^2
Thermosetting ± 1.68
insulated& N/mm^2
695 Tensile at break BS 7211: 2012 0.1 N/mmsq to PermanentFacility
thermoplastic sheathed @ 171.564
cables 24517 N/mmsq N/mm^2
Thermosetting ± 0.10
696 Insulated, armored Dimensions, Thickness BS 6724: 2016 0.01 mm to 300 mm mm @ PermanentFacility
ofInsulation & Sheath
cable 0.82 mm
± 0.02
Thermosetting
Conductor resistance 0.02 micro ohmto 1.1 ohm/km @
697 insulated, armored BS 6724: 2016 PermanentFacility
test ohm 3.112
cables
ohm/km
± 0.02
Thermosetting
Conductor Resistance 0.02 micro ohmto 1.1 ohm/km @
698 insulated, armored fire BS 7846: 2015 PermanentFacility
Test ohm 3.112
resistant cables
ohm/km
Thermosetting ± 0.10
Dimensions, Thickness mm @
699 Insulated, armored, fire BS 7846: 2015 0.01 mm to 300 mm PermanentFacility
ofInsulation & Sheath
resistant cable 0.82 mm
Determination of the ±1.43
Thermosetting amountof halogen acid
mg/gm @
700 insulated, armoured gas evolution - BS 6724: 2016 1 mg to 200 gm PermanentFacility
142.657
cable Corrosive & halogen
mg/gm
acid gas
Thermosetting Armour wires for
701 insulated, armoured Cables(Round, BS 6724: 2016 Qualitative @ PermanentFacility
cables Formed, Strips)
Thermosetting
702 insulated, armoured Cold Bend Test BS 6724: 2016 Qualitative @ PermanentFacility
cables
Thermosetting
703 insulated, armoured Cold Impact Test BS 6724: 2016 Qualitative @ PermanentFacility
cables
Thermosetting ± 1.20
704 insulated, armoured Flammability Test BS 6724: 2016 0.02 mm to 600 mm mm @ PermanentFacility
cables 395.2 mm
Thermosetting ± 0.11 m
705 insulated, armoured Flammability test on BS 6724: 2016 1 mm to 3050 mm PermanentFacility
bunchedcables @ 0.432 m
cables
Thermosetting ± 0.60
706 insulated, armoured Hot set test BS 6724: 2016 0.01 mm to 300 mm mm @ PermanentFacility
cables 10.376 mm
Thermosetting ± 1.2 mm
707 insulated, armoured Shrinkage Test BS 6724: 2016 1 mm to 610 mm PermanentFacility
cables @ 3.4 mm
± 0.011
Thermosetting
Water absorption mg/cm^2
708 insulated, armoured BS 6724: 2016 1 mg to 200 gm PermanentFacility
test(gravimetric) @ 0.04632
cables
mg/cm^2
Thermosetting Armour wires for
709 insulated, armoured, Cables(Round, BS 7846: 2015 Qualitative @ PermanentFacility
fire-resistant cables Formed, Strips)
Thermosetting
710 insulated, armoured, Cold Bend Test BS 7846: 2015 Qualitative @ PermanentFacility
fire-resistant cables
Determination of the
±1.43
Thermosetting amountof halogen acid
mg/gm @
711 insulated, armoured, gas evolution - BS 7846: 2015 1 mg to 200 gm PermanentFacility
142.657
fire-resistant cables Corrosive & halogen
mg/gm
acid gas
Thermosetting ± 1.20
712 insulated, armoured, Flammability Test BS 7846: 2015 0.02 mm to 600 mm mm @ PermanentFacility
fire-resistant cables 395.2 mm
Thermosetting ± 0.11 m
Flammability test on
713 insulated, armoured, BS 7846: 2015 1 mm to 3050 mm PermanentFacility
bunchedcables @ 0.432 m
fire-resistant cables
Thermosetting ± 0.60
714 insulated, armoured, Hot set test BS 7846: 2015 1 mm to 610 mm mm @ PermanentFacility
fire-resistant cables 10.376 mm
Thermosetting ± 1.2 mm
715 insulated, armoured, Shrinkage Test BS 7846: 2015 1 mm to 610 mm PermanentFacility
fire-resistant cables @ 3.4 mm
± 0.011
Thermosetting
Water absorption mg/cm^2
716 insulated, armoured, BS 7846: 2015 1 mg to 200 gm PermanentFacility
test(gravimetric) @ 0.04632
fire-resistant cables
mg/cm^2
Thermosetting
insulated, non armored ±0.70
cable for fixedinsulation mm @
717 Elongation at break BS 7889: 2012 1 mm to 610 mm PermanentFacility
for working voltage up
to and 46.4 mm
including600/1000 V
Thermosetting
insulated, non armored ± 1.74
cable for fixedinsulation Tensile strength at N/mm^2
718 BS 7889: 2012 0.1 N/mmto 25 PermanentFacility
for working voltage up break @ 19.414
to and N/mm N/mm^2
including600/1000 V
± 4.99
N/mm^2
719 Welding Cable Ageing in Air Oven IS 9857: 1990 0.1 N/mmto 25 PermanentFacility
@ 1.652
N/mm N/mm^2
± 1.20
720 Welding Cable Flammability Test IS 9857: 1990 0.02 mm to 600 mm mm @ PermanentFacility
395.2 mm
± 2.45
721 Welding Cables Annealing Test IS 9857: 1990 1 mm to 610 mm mm @ PermanentFacility
34.7 mm
722 Welding cables Armouring IS 9857: 1990 Qualitative @ PermanentFacility
± 0.02
Conductor Resistance 0.02 micro ohmto 1.1 ohm/km @
723 Welding cables IS 9857: 1990 PermanentFacility
Test ohm 3.112
ohm/km
± 0.10
Dimensions, Thickness
724 welding cables IS 9857: 1990 0.01 mm to 300 mm mm @ PermanentFacility
ofInsulation & Sheath
0.82 mm
±0.70
725 Welding Cables Elongation at break IS 9857: 1990 1 mm to 610 mm mm @ PermanentFacility
46.4 mm
High Voltage- at
726 Welding Cables IS 9857: 1990 Qualitative @ PermanentFacility
roomtemperature
± 0.60
727 welding cables Hot set test IS 9857: 1990 0.01 mm to 300 mm mm @ PermanentFacility
10.376 mm
± 1.74
Tensile strength at N/mm^2
728 Welding Cables IS 9857: 1990 0.1 N/mmto 25 PermanentFacility
break @ 19.414
N/mm N/mm^2
--------------End of Report--------------