Download as pdf or txt
Download as pdf or txt
You are on page 1of 404

Industrial Identification

Systems for Manufacturing, Logistics and Distribution


11001110100101101111010001011011101000
11101010110111101001110100010011001011
01111010001011011101000111010010110110
01101000101100110111101000101101110100
01011011101000101011111010001011011100
111010001011011
1110
110100
100010
010110
0111
1 01000111
11101000101101111010001011011101000111
101000110100010
010
0 10
01111
11
11
1 10
101
1 0 000
00
0 011
11
1 10
011
011 01000101
10100011010001011110100011101101000101
1011010001011
1011001110101111
10
1 0
010001011
1011010001011011001110101111010001011
0111101000101
1101111010001000
01101101010
0111101000101101111010001000101101010
001011001110100
00
00010
01
10
10110
11
1 1
100111
11
111
11 10
101
01
0 100
00010110111
000
00101100111010001011011110100010110111
0100011100110
00111010001011011
1110100010
01000111001100111010001011011110100010
1101110100010
01000101101001110
0100010110
11011101000101000101101001110100010110
11110100010110
0111010001110100
0010111101
11110100010110111010001110100010111101
000
01111
11011
11
1111
110
1 100
0 010
00 010110
1 1111010
00001011011
0001110111101000101101111010001011011
With over 50 years of sensor experience, Balluff is a leading global You too can profit from
sensor specialist with its own line of connectivity products for every long years of Balluff industrial
area of factory automation. Balluff is based in Germany and has a identification expertise.
tight international network of 54 representatives and subsidiaries.

Balluff stands for comprehensive systems from a single source, con-


tinuous innovation, state-of-the-art technology, highest quality, and
greatest reliability. That‘s not all: Balluff also stands for exceptional
customer orientation, customized solutions, fast worldwide service,
and outstanding application assistance.

High-quality, innovative products tested in our own accredited


laboratory and a quality management system certified according
to DIN ISO 9001 (EN 2008) form a secure foundation for optimized
added value for our customers.

Whether electronic and mechanical sensors, rotary and linear trans-


ducers, identification systems or optimized connection technology
for high-performance automation, Balluff masters not only the entire
technological variety with all of the different operating principles, but
also provides technology that fulfills regional quality standards and
is suitable for use worldwide. Wherever you are in the world, Balluff
technology is never far away. You won‘t have to look far for you
nearest Balluff expert.

Balluff products increase performance, quality and productivity


around the world every day. They satisfy prerequisites for meeting
demands for greater performance and cost reductions on the global
market. Including in the most demanding areas. No matter how
stringent your requirements may be, Balluff delivers state-of-the-art
solutions.

2
Industrial Identification
Systems for Manufacturing, Logistics and Distribution

Electro-Magnetic BIS U Industrial RFID System 20


Identification

868 MHz UHF


Inductive BIS M Industrial RFID System 34
Identification

13.56 MHz HF
BIS C Industrial RFID System 128

70 kHz LF
BIS L Industrial RFID System 184

125 kHz LF
BIS S Industrial RFID System 236

3.65 MHz HF
Vision-Based BVS Industrial RFID System 250
Identification

Industrial Networking and Connectivity − A selection 270


You will find many additional products in our total product line,
Industrial networking and connectivity – system technology

Accessories − A selection 312


You will find many additional products in our total product line,
Accessories product line – optimal peripherals for sensors

Basic Information and Definitions 352

Alphanumerical directory 382


Worldwide Sales 392

■ www.balluff.com 3
Sophisticated Technology
for All Areas of Automation

Automotive industry: Factory automation, plant engineering, welding and stamping


Mechanical engineering: Steel plants, machine tools, packaging machinery, plastic and rubber machinery
Energy: Conventional and renewable energies
Drive technology: Hydraulic and electric drive technology

Additional areas: Medical technology, semiconductor equipment, wood-, mining-, printing- and paper machinery, ...

4
868 MHz UHF

13.56 MHz HF

70 kHz LF

125 kHz LF

3.65 MHz HF

■ www.balluff.com 5
Customized Services
Balluff stands for comprehensive systems
from a single source

Systems and Service, Industrial Networking and Connectivity, Industrial Identification:


Industrial RFID systems, vision sensors, fieldbus modules, passive splitters,
inductive couplers, IO-Link, plug connectors and connecting cables

6
868 MHz UHF

13.56 MHz HF

70 kHz LF

125 kHz LF

3.65 MHz HF

HMI

Controller

Industrial Networking
and Connectivity

Sensors and
Solutions

■ www.balluff.com 7
Sensor Solutions
Balluff offers suitable products
for every application

Object detection, position and distance measurement, status monitoring and fluid sensors, accessories:
Inductive sensors, capacitive sensors, magnetic sensors, photoelectric sensors, mechanical sensors, ultrasonic sensors,
inductive distance sensors, magneto-inductive displacement sensors, micropulse transducers, photoelectric distance
sensors, magnetically coded position and angle measurement systems, inductive positioning systems, inclination sensors,
pressure sensors, mechanical accessories, electrical accessories

8
868 MHz UHF

13.56 MHz HF

70 kHz LF

125 kHz LF

3.65 MHz HF

HMI

Controller

Industrial Networking
and Connectivity

Sensors and
Solutions

■ www.balluff.com 9
Conveniently Use
the Most Current Data
Information available online all over the world

■ Products in overview ■ 2D and 3D product data

■ Current information at a glance ■ Company

■ Service and support ■ We are happy to help

10
868 MHz UHF

13.56 MHz HF

70 kHz LF

125 kHz LF

3.65 MHz HF

■ www.balluff.com 11
Industrial Identification
For best quality and cost saving

Industrial identification with experience Maximum reliability and transparency


Balluff‘s industrial identification experience goes back to the 1980‘s. Balluff industrial identification leads the way in applications that requi-
We were a pioneer in the field of industrial identification with low re high quality, a high degree of production reliability and optimized
frequency systems designed specifically for manufacturing. Today, processes.
Balluff is still a leader with RFID technologies as well as vision sen- Our industrial graded BIS RFID identification systems achieve an
sors and stationary bar-code readers. Our experience has enabled extremely high degree of quality regarding handling and assembly,
us to provide field-proven solutions for traceability, tool manage- commodity production and storage, internal company logistics and
ment and driverless transport systems in advanced manufacturing access control. Even tool management and driverless transport
facilities. systems operate faultlessly with BIS.
BIS data carriers can record the complete production process of
A multiple auto-ID platform approach any part of any batch and store it for a long time. Thus they enable
Our systems utilize a multiple platform approach to provide best so- traceablity applications for your products through a production
lutions for integrating industrial identification into a process. Regard- and store all data for possible retracing at a later stage. Errors are
less of the needed technology or controlling system requirements, consistently prevented as a result. Defective parts can be traced and
Balluff has the platform solution. This approach gives our customers can either be returned or corrected. The identification process is fully
the architecture and communication structures they need. automatic, reliable and fast. Balluff Industrial RFIDs can manage a
large number of variants and control processes automatically.
Increased productivity
Reliable traceability of the production and quality data brings maxi- Balluff Industrial RFIDs guarantee a high degree of reliability and
mum transparency to your supply and production chain. You know quality, even in harsh environments. Balluff data carriers are resistant
exactly which materials are being used when and where, which serial to shocks, vibrations, high electrical, inductive and electromagne-
numbers are being used and which machines were employed in the tic interference and are insensitive to aggressive materials. Goods
process. Data and commodity flows can be linked with each other, manufactured using Balluff Industrial RFID are renowned for their
so that delivery chains and inner-facility material flow are both opti- high quality.
mized. Industrial identification thereby prevents quality fluctuations.
Rework and no-charge replacements are reduced to a minimum. Balluff BVS vision sensor systems provide visual sensing solutions to
Take full advantage of the absolute reliability of BIS for your supply address the growing demands for higher productivity, flexibility and
chain management. 100 % quality in modern production lines. The BVS offers a full tool
Fewer failures, increased productivity, secure market share, higher box of advanced machine vision functions that can be combined to
sales and greatest possible customer satisfaction through top quality reliably solve error proofing, quality checking and bar code reading
passed along to your customers. Use all this to improve your posi- applications. We can guarantee a device that proves its value for our
tion against the competition. customers thousands of times each day

Balluff industrial identification for Balluff industrial identification products for


■ Optimized material flow ■ Consistent error prevention
■ Increased productivity ■ Secure process control
■ Best customer satisfaction ■ Optimized production
■ Gaining competitive advantage ■ Flexible quality control
■ Reliable traceability with RFID or optical codes
■ Multiple feature check on one part with BVS

12
868 MHz UHF

Greater flexibility Quicker return on investment


Our BIS RFID systems can increase your cycle frequency, as the Industrial identification amortize within a very short period. The return
13.56 MHz HF
data is transferred reliably when the data carrier passes by, even in on investment (ROI) is so quick that the purchase of the BIS alone
high-speed applications. There is greater flexibility because Balluff contributes to the success of your company. Data carriers are also
Industrial RFIDs are available with unlimited read/write cycles and reusable. New product lines that incorporate industrial identification
different memory sizes. have extremely short lead times, irrespective of whether alternating
Expertise in designing solutions and secure integration – even when variants, minimum batch sizes or series products are manufactured.
space is limited – results in a wide variety of components cast in Use Balluff industrial identification to stay one step ahead of the 70 kHz LF
different shapes such as disc, cylinder, cube or handy credit card competition.
format. International approvals allow global distribution. Simply choo- Whenever you require a system for reliable production, our skilled
se from a comprehensive selection of system products according consultants are ready to provide you with appropriate advice. All over
to your application requirements. Your requirements determine the the world and according to your specific requirements – we will be
function and size of the products. glad to answer any questions you may have. 125 kHz LF

Balluff industrial identification systems are Balluff industrial identification


■ Available in various form factors, in plastic or metal ■ Are inexpensive
■ Compatible with any controller ■ Can be reused
■ Suitable for any commonly used bus system ■ Amortize quickly 3.65 MHz HF
■ Usable anywhere in the world

Costs (€)

One-off investment costs

Costs for conventional


handling

Annual savings

Cost with Balluff Machine life (years)


industrial Identification

■ www.balluff.com 13
BIS Industrial RFID Systems
For reliable and high-performance data communication

Why RFID? What is RFID?


Modern production technologies with greater batch sizes and ever RFID means Radio Frequency Identification and stands for automatic
shorter production cycle times require unambiguous recognition identification of any kind of object. A data carrier is affixed to the
and matching of the produced parts. In response, various systems identification object and acts as a portable, moving memory. The
for industrial identification such as bar codes have been developed. data are sent back and forth between the data carrier and read or
These are cost-effective, but wear quickly. In addition, they are inhe- read/write head using inductive coupling. The read head then sends
rently read-only and hold a limited amount of data. the data to the host controller. Industrial RFID is fast and reliable,
even with changing objects and large amounts of data. This means
Far greater flexibility is provided by industrial RFID, inductive identifi- that objects can be simply identified and tracked.
cation systems with read and write capability for ensuring the most
current data in every single process segment. Balluff Industrial RFID The inductive principle guarantees ruggedness and insen-
BIS reliably process large quantities of data without making visual sitivity to the surroundings, making these systems highly
contact. reliable. Balluff Industrial RFIDs are therefore suitable for
use in harsh environments.
Unlimited read/write cycles ensure flexible, rapid, contact-free
communication even for the transfer of large data quantities in highly
dynamic applications. Our wear-free BIS are easy to integrate in all
types of controller.

Economical Balluff identification systems are able to manage the


large volumes of information required in modern-day production
plants and make sure your data is transferred to the right place at
the right time. All relevant production and quality data is stored and
made available for retrieval at any time: for optimized production
processes and maximum production reliability.
Profit from the advantages of Balluff Industrial RFID and benefit from
more than 20 years of Balluff RFID expertise. Simply select from the
product range according to your application requirements.

Advantages
■ for quick, flexible non-contact data communication
without visual contact
■ suitable for any industrial environment
■ powerful and economical
Memory device
Data carrier/memory size
Read/write cycle
Max. read/write distance
Read/write time (64 bytes)
Operating frequency
Dynamic reading/writing
Data storage time
Degree of protection
Norms/Standards

14
868 MHz UHF

13.56 MHz HF

70 kHz LF

Five systems – maximum versatility Take advantage of the different system versions:
Balluff Industrial RFID offer four different systems with varied ■ versatile BIS C ideal for a wide range of applications: 125 kHz LF
components for a wide range of applications. One system is simply extremely powerful and versatile for reliable tool identification in
not sufficient for different applications such as machining centers that process coolants and lubricants or
sterilization under high temperatures in a vacuum of an autoclave
■ Forgery/Copy protection ■ economical BIS L for logistics and assembly lines
■ Maintenance/Servicing ■ BIS M with lighting-fast data transfer and large read/write 3.65 MHz HF
■ Tool management distance for internal company logistics, access control or copy
■ Production control protection and
■ Access control ■ BIS S for transferring large quantities of data to control assembly
■ Container management and production facilities
■ Consignment
■ Stock management System components
■ Tracking of goods Balluff Industrial RFID systems consist of a data carrier, the so-
■ Incoming/Outgoing goods called tag, a read or read/write head, and the processor.

In addition, requirements for Industrial RFID have increased drastical- The tag is used to read and store data. Data quantities and read/
ly over the last few years. Production control has benefited from data write cycles depend on the memory device. Balluff data carriers
carriers with a large memory capacity, for example, while greater draw their power from the read/write unit. No batteries are required.
data security is available for copy protection. The read/write distance The electronics and antenna are integrated into the tag. The range is
for tracking goods is usually large, but for access control is relatively defined by the capacity and frequency of the tag.
small. Tool management usually requires small, extremely robust
data carriers which would be too large for consignment. So select
the best solution for you from four different systems with various
transfer frequencies. Optimized specifically for your application.

BIS U BIS M BIS C BIS L BIS S


EEPROM EEPROM FRAM EEPROM FRAM EEPROM FRAM
512 bit 752 bytes 2000 bytes 511...1023 bytes 8 kBytes 192 bytes 32 kBytes
100,000 100,000 unlimited 1,000,000 unlimited 100,000 unlimited
upt to 6 m (typ.) 150 mm 300 mm 90 mm 100 mm 100 mm 50 mm
230 ms/900ms 60 ms/130 ms 60 ms/130 ms 220 ms/860 ms 220 ms/860 ms 1530 ms/3530 ms 29 ms/120 ms
860...960 MHz 13.56 MHz 13.56 MHz 70 kHz/455 kHz 70 kHz/455 kHz 125 kHz 1 MHz/3.56 MHz
yes/yes yes/yes yes/yes yes/yes yes/yes yes/no no/no
10 years 10 years 10 years 10 years 10 years 10 years 10 years
IP 65 IP 67 IP 67 IP 67 IP 67 IP 67 IP 67
EPC Gen 2, Class1, ISO 14443 ISO 15693 DIN 69873 DIN 69873
ISO 18000-6C

The specifications in the table are system-specific and not valid for each individual product. Refer to the relevant catalog for more detailed specifications.

■ www.balluff.com 15
BVS Vision Sensors
For higher productivity, greater efficiency,
best quality and lowering costs
Why a BVS Vision Sensor? Four models – greater flexibility
With ever growing demands for higher productivity, greater With four levels of Balluff BVS-E Vision Sensor functionality, choose
efficiency, 100% quality and lowering costs, the Balluff BVS Vision the best one to solve the application at a price point that makes sen-
Sensors provide visual sensing solutions to address all these needs. se. Configure the BVS by combining several different tools using the
Typically for complex multiple visual inspections, an array of sensors same PC software interface with just 3 easy steps. Once configured,
and code readers are employed. By using a BVS vision sensor, it can check as many as 255 features in one inspection while running
multiple visual inspections and bar code reading can all be addres- fully automatic.
sed reliably by the same sensor, dramatically lowering hardware cost
while greatly increasing sensing reliability. The BVS can also change System components
inspection jobs while in-process eliminating the need for hardware ■ BVS-E Identification –
or setup changes, increasing productivity and efficiency. The BVS is Easily and reliably read a large number of codes
designed to be a flexible, vision-based sensing solution to address ■ BVS-E Standard –
today‘s production sensing needs. Sensor of choice for simple error proofing tasks
■ BVS-E Advanced –
■ Replace different sensor functions with one part 360° detection of parts for optimized process control
■ Greater configuration flexibility ■ BVS-E Universal –
■ Easy to use, single PC software interface Versatile tools for demanding quality checking
■ Industrial grade, flexible mounting and part positioning
■ BVS-E Monitor –
Lower cost and faster ROI A small and easy to use visualisation accessory
■ Hardware: Reduce hardware costs. One BVS Vision Sensor can compatible for each BVS-E model
replace up to 255 standard sensors.
■ Engineering and project planning: Instead of using a sensor
array and multiple pieces of mounting hardware, use a single BVS.
Significantly reduce setup and change-over times, simplify designs
and reduce over all hardware costs. Several flexible BVS mounting
options are available.
■ Startup: Startup and configuration: Configuration of any BVS
is simple using a single intuitive PC software interface. With the
easy 3-step setup process, no complex programing language or
expensive training is required.
■ Operation and maintenance: No time consuming and complex
multi-sensor realignment is necessary with product change-overs.
The BVS allows for multiple inspection jobs that can be easily
changed electronically, reducing effort and increasing productivity.

Model BVS Vision BVS Vision BVS Vision BVS Vision


Sensors Sensors Sensors Sensors
Identification Standard Advanced Universal
Bus interfaces TCP/IP ■ ■ ■
RS232 ■ ■
Features Basic error profing tools ■ ■ ■ ■
Read Barcodes ■ ■
Read Datamatrixcodes ■ ■
360° detection of codes ■ ■
360° detection of parts ■ ■
Typical detection rate up to 40 Hz 15 Hz up to 40 Hz up to 40 Hz
Working dis- 50...1000 mm ■ ■ ■ ■
tance 180...1000 mm ■ ■ ■
Lighting LED, red light ■ ■ ■ ■
LED, infrared ■ ■ ■ ■
Degree of protection per IEC 60529 IP 54 IP 54 IP 54 IP 54
Ambient temperature range Ta –10...+55 °C –10...+55 °C –10...+55 °C –10...+55 °C

16
868 MHz UHF

13.56 MHz HF

70 kHz LF

125 kHz LF

3.65 MHz HF

17
Comprehensive System
Expertise from a Single Source

Electro-Magnetic Identification Inductive Identification

868 MHz UHF 13.56 MHz HF 70 kHz LF

Industrial RFID System Industrial RFID System Industrial RFID System


BIS U BIS M BIS C

The BIS U system uses Ultra High Fre- The BIS M system uses a High Frequen- The BIS C system uses a Dual Low
quency or UHF 865...928 MHz propaga- cy or HF 13.56 MHz inductively coupled Frequency 433 kHz read and 70 kHz write
ting wave and back scatter technology technology along with passive tags to inductively coupled technology along with
along with passive tags to provide very provide mid-range RFID solutions as passive tags to provide short range RFID
long range RFID solutions as far as 6 m. far as 400 mm. This system is ideal for solutions up to 100 mm for WIP (work in
This system is ideal for asset as well as closer range asset tracking, WIP (work in process) or production control such as
intra or inter logistics tracking and identi- process) or production control such as palletized production or "on part" tracking
fication applications. The BIS U includes palletized production or "on part" tracking and quality traceability applications. The
high temperature and metal mounted tag and quality traceability applications. This BIS C system is also uniquely designed
solutions as well as combination hardened system also offers high temperature, metal for solving machine tool identification ap-
and disposable tags that can be used mount, hardened and disposable tagging plications. This system can be used flush
to provide the most cost effective and options. in, on or off metal and provides hardened
reliable solution. re-usable tagging options.

page 20 page 34 page 128


18
868 MHz UHF

13.56 MHz HF

70 kHz LF

Vision-Based Identification 125 kHz LF

125 kHz LF 3.65 MHz HF 3.65 MHz HF

Industrial RFID System Industrial RFID System Vision Sensors


BIS L BIS S BVS

The BIS L system uses a Low Frequency The BIS S system uses a Dual Frequen- When looking for reliable error detection
or LF 125 kHz inductively coupled cy 3.65 MHz read and 560 KHz write and quality testing while working with mul-
technology along with passive tags to inductively coupled technology along with tiple product features at the same time,
provide shorter range RFID solutions up passive tags to provide short range RFID use the BVS-E Vision Sensor to simplify
to 100 mm for WIP (work in process) or solutions up to 50 mm for applications these complex sensing applications. The
production control such as palletized that require high capacity memory for up BVS-E can also minimize change-over
production and quality traceability appli- to 32 kBytes of data. This system was time when checking different parts on the
cations. The BIS L system is also used for specially designed for WIP (work in pro- same production line. This can increase a
lower cost read-only tracking applications cess) or production control such as pal- lines throughput rates and help increase
when only an identifier is required. This letized production and quality traceability quality and productivity levels. All the
system can be used on or off metal and applications. This system is used on metal BVS-E vision sensors use the same, easy
provides hardened re-usable tagging and provides hardened re-usable tagging to use PC-based configuration software
options. options. providing consistency across the entire
product family.

page 184 page 236 page 250


■ www.balluff.com 19
BIS U
Industrial
868 MHz
RFID
UHF
System
Electro-magnetic identification
The BIS U system uses Ultra High Frequency or UHF 865 to
928 MHz propagating wave and back scatter technology along with
passive tags to provide very long range RFID solutions as far as 6 m.
This system is ideal for asset as well as intra or inter logistics tracking
and identification applications. The BIS U includes high temperature
and metal mounted tag solutions as well as combination hardened
and disposable tags that can be used to provide the most cost
effective and reliable solution.

Host
controller
PLC, PC
based handheld
Windows®

Processors

Antennas

Data carriers

20
BIS U Industrial RFID System
Electro-magnetic identification

Process visibility and applications 22


Passive UHF tags 24
UHF single channel processors 26
UHF Multi-channel processors 28
UHF antennas 30 868 MHz UHF
UHF handheld 32

Basic information
and definitions
can be found
on page 352

■ www.balluff.com 21
BIS U Industrial RFID System
Process visibility and applications

The right data at the


right time at the right place

Features Benefits
■ Supports standard EPC Gen 2 tags ■ Tags available for any asset no matter how large or
■ Supports multiple enterprise or control interface options small and regardless of material
■ Up to four antennas can be used on one controller ■ Integration into most current system
■ Does not require line of site ■ Multiple antennas provide redundant, reliable data
■ Passive tags require no batteries ■ Identifies multiple assets without having to
scan each item separately
■ Low cost passive tags ensure cost effectiveness,
or durability, and longevity
■ No battery replacement needed

22
BIS U Industrial RFID System
Process visibility and applications

868 MHz UHF


BIS U Industrial
RFID System
Process
visibility and
applications
Operation principles The BIS U Identification System is classified as a non-contacting Passive
UHF tags
of the system system with read and write functionality for single or multiple UHF
UHF
tags. This allows it to transport not only programmed information single channel
that is fixed on the data carrier (tag), but also to collect and pass on processors
UHF
tag information to interfacing control or data collection systems. multi-channel
processors
The main components of the BIS U Identification System are: UHF antennas
■ Processor UHF handheld
■ Antennas(s)
■ Data carrier (tag)
3 4 5 6 7

2
1 PC
2 PLC
3 Connection to the host system
4 Processor unit 1
5 Antenna cable
6 Antennas (max. 4)
7 Data carrier

Asset tracking UHF-based RFID provides a means of identifying and tracking


assets like tools, production equipment, medical devices, installed
parts, logistic containers, and even reusable assets like totes,
bins and skids.

Logistics tracking Tracking incoming and outgoing shipments of parts and products
are key to the efficiency and operation of any production facility.
UHF-based RFID enables a reliable, non-visual way to identify
multiple containers and shipment information quickly and reliably.

Closed loop and When moving parts from suppliers to main production facilities,
supply chain logistics UHF-based RFID can be a significantly more reliable and a faster
way to identify incoming shipments, contents and reusable assets
like totes, part containers, skids, and transport containers.

Production tracking During the production process, RFID can be used to track
parts and enable visibility into the process itself. UHF-based RFID
can provide a means to track parts or part pallets at greater
distances allowing greater freedom of use.

e-Kanban Electronic Kanban is a messaging system that allows a mix


of information and control for the tracking and movement of
production components. e-Kanban can be used to provide faster
flow of information and replaces traditional elements such as
cards with RFID and barcode.

■ www.balluff.com 23
BIS U Industrial RFID System
Passive UHF tags

■ Great range on or off metal


(with holder or spacer)
■ Rugged housing
■ Available for high temperature
applications

Specialty tags
Balluff can offer a wide variety
of highly specialized UHF RFID
tags. From tiny metal mount tags
designed to track individual tools Dimensions 127
127×37.2×7
37 2 7 mm
to the larger tags designed to Housing material PA 12 (fiberglass reinforced)
track vehicles, Balluff can help Weight 18 g
match the right tag to the right For Europe
assets. In addition to rugged Frequency range Ordering code BIS00NL
tags used in harsh environments, 865...868 MHz Part number BIS U-100-01/CA
Balluff can also provide tags in For America/Asia
paper (label) and other synthetic Frequency range Ordering code BIS00RC
materials. Tag selection should 902...928 MHz Part number BIS U-100-02/CA
be based on the environment For Global
and the asset. Contact Balluff Frequency range Ordering code
for additional tagging options. 860...960 MHz Part number
Mounting
User data 512 bit EEPROM
Frequency 865...960 MHz
Degree of protection per IEC 60529 IP 67
Memory capacity read/write 96...480 bit EPC,
512 bit user memory
Standards EPC, Class 1, Gen 2,
ISO 18000-6C
Operating temperature –40...+85 °C
Storage temperature –40...+85 °C

For mounting pay attention to Basic Information chapter.


127
non-metal (on metal only with spacer) 117
114 1.7

5.3
37.2

6.8
7

24
BIS U Industrial RFID System
Passive UHF tags

High
Temperature

High
Temperature 868 MHz UHF
BIS U Industrial
RFID System
Process
visibility and
applications
Passive
51.5×51.5×6.5 mm 127.7×51.5×11 mm 51.5×51.5×6.5 mm 127.7×51.5×11 mm UHF tags
ABS ABS PPS PPS UHF
single channel
32 g 48 g 47 g 70 g processors
UHF
multi-channel
processors
UHF antennas
UHF handheld

BIS00WH BIS00WE BIS00WF BIS00WC


BIS U-101-04/CA BIS U-102-05/CA BIS U-101-04/CA-HT BIS U-102-05/CA-HT

512 bit EEPROM 512 bit EEPROM 512 bit EEPROM 512 bit EEPROM
860...960 MHz (Global) 860...960 MHz (Global) 860...960 MHz (Global) 860...960 MHz (Global)
IP 67 IP 67 IP 67 IP 67
240 bit EPC, 240 bit EPC, 240 bit EPC, 240 bit EPC,
512 bit user memory 512 bit user memory 512 bit user memory 512 bit user memory
EPC, Class 1, Gen 2, EPC, Class 1, Gen 2, EPC, Class 1, Gen 2, EPC, Class 1, Gen 2,
ISO 18000-6C ISO 18000-6C ISO 18000-6C ISO 18000-6C
–40...+85 °C –40...+85 °C –40...+85 °C –40...+85 °C
–40...+85 °C –40...+85 °C –40...+220 °C –40...+220 °C

Ø 10.5 Ø 10.5
Ø 5.5 Ø 5.5
6.5
6.5

51
51

■ www.balluff.com 25
BIS U Industrial RFID System
UHF single channel processors

Single antenna

Function
Housing material
Weight
Highly visible
status LEDs For Europe
Frequency range Ordering code
865...868 MHz Part number
Rugged metal For USA/Canada
housing Frequency range Ordering code
902...928 MHz Part number
Secure contact by
means of industrial Operating voltage
connectors Current consumption at 24 V DC
Application interface
Connection power supply, interface
Connection control inputs, outputs (1× DI, 2× DO)
Antenna ports
Degree of protection per IEC 60529
Connection cable

For installation pay attention


to Basic Information chapter.

Serial

RS232 interface
Digital I/O

Serial/Power
interface RS232

Serial

RS485 interface
Digital I/O

Serial/Power
interface RS485

Ethernet Ethernet interface


TCP/IP
Ethernet interface Ethernet/IP
Modbus TCP

Digital I/O

24 V DC power
connection

1 antenna on top

26
BIS U Industrial RFID System
UHF single channel processors

868 MHz UHF


BIS U Industrial
Serial Serial Ethernet RFID System
Process
visibility and
applications
Passive
Read/write Read/write Read/write UHF tags
Aluminum Aluminum Aluminum UHF
single channel
497 g 497 g 497 g processors
UHF
multi-channel
BIS00Z4 BIS00Z8 BIS00Z0 processors
BIS U-620-068-101-00-ST29 BIS U-620-067-101-04-ST30 BIS U-626-069-101-06-ST32 UHF antennas
UHF handheld
BIS00Z2 BIS00Z6 BIS00YY
BIS U-620-068-111-00-ST29 BIS U-620-067-111-04-ST30 BIS U-626-069-111-06-ST32
24 V DC (10...30 V DC) 24 V DC (10...30 V DC) 24 V DC (10...30 V DC)
≤1A ≤1A ≤1A
Serial RS232 Serial RS485 Ethernet, TCP/IP, Modbus TCP
1× M12 connector male, 8-pin 1× M12 connector male, 5-pin 1× M12 connector male, 5-pin
1× M12 connector female, 8-pin 1× M12 connector female, 8-pin 1× M12 connector female, 8-pin
1× R-TNC connector male 1× R-TNC connector male 1× R-TNC connector male
IP 65 IP 65 IP 65
See page 272/302 for cable options See page 272/302 for cable options See page 272/292 for cable options

112 112 112


48

48

48
38 54 38 54 38 25 29
5.3 5.3 5.3
4

NODE ID IP ADDRESS
157.6

157.6

157.6

READY 1 READY DEFAULT READY


164

164

164

RF 2 RF CUSTOM RF
4
COM COM COM
8
16

RS232/V DC I/O RS485/V DC I/O ETHERNET V DC I/O

98 Ø 5.3 98 Ø 5.3 98 Ø 5.3

■ www.balluff.com 27
BIS U Industrial RFID System
UHF multi-channel processors

■ Simple mounting with Up to 4 antennas

standard accessories
■ Metal connector
for secure connection
■ Rugged housing for
use where you need it

Function
Housing material
Weight
For Europe
Frequency range Ordering code
865...868 MHz Part number
For USA/Canada/Mexico
Frequency range Ordering code
902...928 MHz Part number
Operating voltage, Ripple
Current consumption at 24 V DC
Service interface
Application interface
Characteristic impedance of antenna ports
Rugged metal Adjustable power at the antenna ports
housing

Connection X1
Highly visible Connection X2
status LEDs Connection X3
Connection X4
Antenna ports 1...4
Degree of protection per IEC 60529
Secure contact Connection cable
by means of
bayonet catch
For installation pay attention
to Basic Information chapter.

Included in the scope of delivery:


■ BIS U-602_
■ 5× closure cap
■ BIS Software-CD
■ Condensed manual in printed form
(DE/EN)

Accessories please order separately:


DLL for integrating the protocol in
PC-based controller or evaluation unit.

Serial PROFINET

RS232 interface Profinet interface


7 5 9c
9a 6/7
8 8 9c
6
Ordering code: BAE00F2
Part number: BIS-Z-SW-UHF-DLL

1 Antenna port 1
2 Antenna port 2
Ethernet
3 Antenna port 3
4 Antenna port 4
Ethernet TCP/IP interface 4 antennas on top
5 Function ground FE
9b 7 5 6 Power supply
8 7 Control inputs / outputs
6 1 2 3 4
I/O ports for additional functionality
8 RS232 service interface
9a Application interface – RS232 variant
9b Application interface – TCP/IP variant
9c Application interface – Profinet

28
BIS U Industrial RFID System
UHF multi-channel processors

868 MHz UHF


BIS U Industrial
Serial Ethernet PROFINET RFID System
Process
visibility and
applications
Passive
Read/write Read/write Read/write UHF tags
Aluminum Aluminum Aluminum UHF
single channel
2100 g 2100 g 2100 g processors
UHF
multi-channel
BIS00M7 BIS00NA BIS00ZU processors
BIS U-6020-053-104-00-ST26 BIS U-6027-054-104-06-ST27 BIS U-6028-048-104-06-ST28 UHF antennas
UHF handheld
BIS00R2 BIS00R1 BIS00ZW
BIS U-6020-059-114-00-ST26 BIS U-6027-060-114-06-ST27 BIS U-6028-048-114-06-ST28
24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 %
≤ 1 A ≤ 1 A ≤ 1 A
RS232 RS232 RS232
RS232 Ethernet TCP/IP Profinet
50 Ω 50 Ω 50 Ω
For Europe 17...33 dBm (50 mW...2 W) For Europe 17...33 dBm (50 mW...2 W) For Europe 17...33 dBm (50 mW...2 W)
For USA 17...30 dBm (50 mW...1 W) For USA 17...30 dBm (50 mW...1 W) For USA 17...30 dBm (50 mW...1 W)
Vs 24 V DC: 1× M12 connector male, 5-pin Vs 24 V DC: 1× M12 connector male, 5-pin Vs 24 V DC: 1× 7/8" connector male, 5-pin
I/O: 1× M12 connector male, 8-pin I/O: 1× M12 connector male, 8-pin Profinet 2: 1× M12 connector male, 4-pin, D-code
Service port: 1× M12 connector male, 4-pin Service port: 1× M12 connector male, 4-pin Profinet 1: 1× M12 connector male, 4-pin, D-code
RS232: 1× M12 connector male, 4-pin TCP/IP: 1× RJ45 bayonet connector Service port: 1× M12 connector male, 4-pin
4× R-TNC connector male 4× R-TNC connector male 4× R-TNC connector male
IP 65 IP 65 IP 65
See page 272/281/305 for cable options See page 272/305 for cable options See page 272/305/306 for cable options

59.8
59.8

59.8
43.5

43.5

43
30.5
34
36
31

36
31

27.5 2×17.5 18.8 27.5 2×17.5 18.8 2x17.5 26 30.3

107.6 107.6 107.6


20 54 20 20 54 20
20 54 20
7
5

5
312
298

298
312
298
312
5

88 88
88
3×26 3×26 3×26
26.8

26.8
26.8
59.8

59.8
59.8

■ www.balluff.com 29
BIS U Industrial RFID System
UHF antennas

The frequency range for UHF


systems is dependent on the
region of use. There are country-
specific variants here as with the
readers. The power available to
the antenna can be flexibly set
via the reader. Regardless of
whether you install the antennas
For Europe
near gates or plan to use them 865...868 MHz
in a conveyor line – the wide
range of accessories simplifies Dimensions 133×133×18
133×133×18.4 4 mm
integration in all places of use. Housing material PC
Weight 365 g
Balluff UHF Antennas Ordering code BIS00P0
■ Simple mounting with Part number BIS U-301-C0-TNCB
standard accessories Frequency range 865...868 MHz
■ Rugged metal connector Approved radiated power < 0.5 W ERP ETSI EN 302208
for secure connection Antenna gain 5.5 dBic
■ Rugged housing built Antenna impedance 50 Ω
for harsh environments Connection type 1× TNC connector female
■ Available in different sizes Degree of protection per IEC 60529 IP 67 (with connector)
Operating temperature Ta –30...+70 °C
Dispersion angle 100° vertical, 100° horizontal
Connection cable See page 272 for cable options

For installation pay attention to 


Basic Information chapter.  



30
BIS U Industrial RFID System
UHF antennas

868 MHz UHF


BIS U Industrial
RFID System
For Process
For America/Asia For Europe America/Asia visibility and
902...928 MHz 865...868 MHz 902...928 MHz applications
Passive
133×133×18 4 mm
133×133×18.4 271
271×271×42.5 mm 271×271×42.5 mm UHF tags
PC Polymer blend Polymer blend UHF
single channel
365 g 1700 g 1700 g processors
BIS00TY BIS00TZ BIS00U0 UHF
multi-channel
BIS U-301-C1-TNCB BIS U-302-C0-TNCB BIS U-302-C1-TNCB processors
902...928 MHz 865...868 MHz 902...928 MHz UHF antennas
< 4 W EIRP FCC < 2 W ERP ETSI EN 302208 < 4 W EIRP FCC CFR47 UHF handheld
5.5 dBic 8.4 dBic 8.4 dBic
50 Ω 50 Ω 50 Ω
1× TNC connector female 1× TNC connector female 1× TNC connector female
IP 67 (with connector) IP 65 IP 65
–30...+70 °C –25...+55 °C –25...+55 °C
100° vertical, 100° horizontal 69° vertical, 69° horizontal 69° vertical, 69° horizontal
See page 272 for cable options See page 272 for cable options See page 272 for cable options

 42.5 271


 


271

49

ª ª

 ª nª
  nª
nª
  ª

  ª nª

  ª nª

  ª nª

  ª nª


n n n D"

ª nª
  

ª n nª


 
n nª
  ª
n nª
  ª
ª nª
   ¢ª

Radiation pattern, horizontal

■ www.balluff.com 31
BIS U Industrial RFID System
UHF handheld

Mobile ID
Ideal even for poor light conditions and harsh environments.
Data transfer via optional WLAN, Bluetooth or wired USB.
The handheld is also modular for expandability.

■ Touchscreen with large color display


■ Windows CE®
■ Preinstalled Balluff software and keyboard

PSION-based UHF handheld


■ Windows CE®
■ Touchscreen
■ Delivered with software development kit (SDK)
■ Includes charger
■ Bluetooth "on-board"

Optional
■ WLAN
■ 1D/2D barcode reader
■ Docking station
■ Pistol grip

Handheld Standard
Customer-specific software on request: BIS U-870-1-008-X-000
00
tecsupport@balluff.com including charger

32
BIS U Industrial RFID System
UHF handheld

868 MHz UHF


BIS U Industrial
RFID System
Process
visibility and
For Europe For USA/Canada applications
Passive
Function UHF handheld UHF handheld UHF tags
Housing material ABS ABS UHF
single channel
Weight 585 g 585 g processors
Standard Ordering code BAE00EE BAE00JR UHF
multi-channel
Part number BIS U-870-1-008-X-000 BIS U-870-1-008-X-000-1 processors
Standard + WLAN Ordering code BAE00J8 UHF antennas
Part number BIS U-870-1-008-X-001 UHF handheld
Indicator TFT touchscreen display TFT touchscreen display
Power supply 3.7 V rechargeable battery pack 3.7 V rechargeable battery pack
Capacity 4000 mA/h 4000 mA/h
Interface Bluetooth/USB Bluetooth/USB
Operating temperature –10...+50 °C –10...+50 °C
Degree of protection per IEC 60529 IP 65 IP 65
Accessories Charging power supply and stylus Charging power supply and stylus
Order accessories separately Docking station and pistol grip Docking station and pistol grip

Standard handheld BIS U-87_-1-008-X-000_ 100 51 100 51


includes charger and stylus.
265

265

Recommended accessories
(please order separately)

Description Pistol grip option Optional docking station


with power supply
Ordering code FHW0004 FHW0003
Part number 11023836 11023834

■ www.balluff.com 33
BIS M
Industrial
RFID
13.56 MHz HF
System
Inductive Identification
Super-fast data transmission and large read/write distances:
BIS M has proven its worth in intralogistics, access control, and
product protection.

Host
controller
PLC, PC

Interface
Profibus, Devicenet

Profibus, Devicenet
Ethernet/IP, Profinet

V-Processor

IO-Link, Serial RS232

Serial RS232,
RS422, USB

Serial RS232,
Profibus, Ethernet/IP,
Ethernet TCP/IP,
Modbus/TCP

Serial RS232, 485,


Ethernet/IP,
Ethernet TCP/IP,
Modbus/TCP

Serial USB,
Standard
Handheld

variations

Processors
Gateway

Read/write
heads

Data carriers

34
BIS M Industrial RFID System
Inductive identification

Range of applications 36
Read/write distances overview 38
Data carriers read/write 42
Read/write heads
Read/write compact processors 62
HF antenna 94
HF antenna compact processor 96
HF long range processors 98
HF long range conveyor antenna 100
HF long range antenna 102 13.56 MHz HF
Processors Serial RS232 108
Profibus 110
Devicenet 112
Ethernet/IP 114
Ethernet TCP/IP 115
Profinet 116
Mitsubishi 118
CC-Link 119
BIS V – New Generation 120
Gateways 122
Standard handheld 124
Access protection 126

Basic information
and definitions
can be found on
page 352

■ www.balluff.com 35
BIS M Industrial RFID System
Range of applications

The main areas of application for the BIS M include internal company
logistics, access control and copy protection. The powerful identifi-
cation system is proven in all applications where lightning-fast data
transfer and large read/write distances are required. Select the most
suitable BIS M system for your application from the table.

Data carrier

Page
BIS003Y BIS M-101-01/L 45
BIS003Z BIS M-102-01/L 46
BIS0040 BIS M-105-01/A 42
BIS0042 BIS M-105-02/A 42
BIS00LC BIS M-107-03/L-H200 61
BIS0043 BIS M-108-02/L 50
BIS0111 BIS M-108-20/A 50
BIS0044 BIS M-110-02/L 43
BIS0045 BIS M-111-02/L 45
BIS0046 BIS M-112-02/L 47
BIS00KM BIS M-115-03/A 51
BIS00RZ BIS M-115-03/A-SA2 51
BIS00UC BIS M-116-03/A 43
BIS00UE BIS M-116-08/A 43
BIS0047 BIS M-120-01/L 51
BIS0048 BIS M-122-01/A 42
BIS0049 BIS M-122-01/A-ZC1 53
BIS004C BIS M-122-02/A-ZC1 53
BIS004A BIS M-122-02/A 42
BIS00T1 BIS M-122-02/A-SA2 54
BIS00YL BIS M-130-03/L 43
BIS00YK BIS M-130-07/L 43
BIS00YF BIS M-132-03/L 44
BIS00YE BIS M-132-03/L-HT 60
BIS00YC BIS M-132-10/L 45
BIS00YA BIS M-132-10/L-HT 60
BIS00Y9 BIS M-133-02/A 45
BIS00Y7 BIS M-134-10/L-HT 60
BIS00Y6 BIS M-135-02/L 49
BIS00Y5 BIS M-135-03/L 49
BIS00Y4 BIS M-135-03/L-HT 61
BIS00Y3 BIS M-135-07/L 49
BIS00Y2 BIS M-135-07/L-HT 61
BIS00W9 BIS M-136-03/L 51
BIS00Y1 BIS M-136-03/L-HT 61
siehe Datenträger BIS M-140-02/A-M_ 57
siehe Datenträger BIS M-142-02/A-M_-GY 55
siehe Datenträger BIS M-142-20/A-M_-GY 55
siehe Datenträger BIS M-143-02/A-M_ 55
siehe Datenträger BIS M-144-02/A-M_-GY 57
BIS004F BIS M-150-02/A 58
BIS004H BIS M-151-02/A 59
BIS00M2 BIS M-152-03/A 53
BIS00P3 BIS M-153-02/A 59
BIS010R BIS M-153-20/A 58
BIS00P1 BIS M-154-03/A 53
BIS0117 BIS M-155-20/A 59
BIS0112 BIS M-156-20/A 59
BIS00NZ BIS M-191-02/A 53

36
Production Intralogistics Access and
object control

Access and entry control


Closed logistics circuits
conveying systems

retrieval equipment

Driverless vehicles

Object detection
management

Storage and
Tool and die

Assembly

Long distances (> 16 mm)


Retainer/workpiece carrier

Retainer/workpiece carrier

For harsh environments


Reliable access control
Workpiece carrier skid

For high temperature


Installation in metal
13.56 MHz HF

Dynamic or static
Guiding, steering

Process access
On component
In component
BIS M

Identification
Industrial

Read/write

EEPROM
RFID System
On part
On tool

Part ID
Pallets

Pallets

Range of

FRAM
applications
Dies

Read/write
distances
■ ■ ■ ■ ■ ■ ■ ■ overview
■ ■ ■ ■ ■ ■ ■ ■ ■ Data carriers
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Read/write
heads
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Read/write
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ compact
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ processors
HF antenna
■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Processors
■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Gateways
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Standard
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ handheld
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Access
protection
■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■
■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■
■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■

■ www.balluff.com 37
BIS M Industrial RFID System
Read/write distances overview

Memory Data carrier 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 100 120 140 160 mm


BIS M-302-00_-...
752 bytes BIS M-101-01/L 0...16
752 bytes BIS M-102-01/L 0...20
752 bytes BIS M-105-01/A 0...7
2000 bytes BIS M-105-02/A 0...9
752 bytes BIS M-122-01/A 0...7
2000 bytes BIS M-122-02/A 0...9
2000 bytes BIS M-108-02/L 0...20
2000 bytes BIS M-110-02/L 0...16
2000 bytes BIS M-111-02/L 0...20
2000 bytes BIS M-112-02/L 0...30
2000 bytes BIS M-140-02/A-M_ 0...14
2000 bytes BIS M-142-02/A-M_ 0...14
2000 bytes BIS M-143-02/A-M_ 0...10
2000 bytes BIS M-144-02/A-M_ 0...14
BIS M-304-00_-...
752 bytes BIS M-101-01/L 0...14
752 bytes BIS M-102-01/L 0...18
752 bytes BIS M-105-01/A 0...5
2000 bytes BIS M-105-02/A 0...7
752 bytes BIS M-122-01/A 0...5
2000 bytes BIS M-122-02/A 0...7
2000 bytes BIS M-108-02/L 0...18
2000 bytes BIS M-110-02/L 0...14
2000 bytes BIS M-122-02/A-SA2 0...5
BIS M-300-00_-…
112 bytes BIS M-115-03/A-SA2 0...18
752 bytes BIS M-101-01/L 0...22
752 bytes BIS M-102-01/L 0...32
752 bytes BIS M-105-01/A 0...9
2000 bytes BIS M-105-02/A 0...11
2000 bytes BIS M-108-02/L 0...30
8192 bytes BIS M-108-20/A 0...30
2000 bytes BIS M-110-02/L 0...22
2000 bytes BIS M-111-02/L 0...28
2000 bytes BIS M-112-02/L 0...44
2000 bytes BIS M-140-02/A-M_ 0...20
2000 bytes BIS M-143-02/A-M_ 0...14
2000 bytes BIS M-144-02/A-M_ 0...17
112 bytes BIS M-102-03/L-H200 0...18
BIS M-400-…-001-…
752 bytes BIS M-101-01/L 0...20
752 bytes BIS M-102-01/L 0...28
752 bytes BIS M-105-01/A 0...7
2000 bytes BIS M-105-02/A 0...11
2000 bytes BIS M-108-02/L 0...28
8192 bytes BIS M-108-20/A 0...28
2000 bytes BIS M-110-02/L 0...20
2000 bytes BIS M-111-02/L 0...28
2000 bytes BIS M-112-02/L 0...38
BIS M-400-…-002-…
752 bytes BIS M-101-01/L 0...15
752 bytes BIS M-102-01/L 0...18
752 bytes BIS M-105-01/A 0...6
2000 bytes BIS M-105-02/A 0...9
752 bytes BIS M-122-01/A 0...5
2000 bytes BIS M-122-02/A 0...6
2000 bytes BIS M-108-02/L 0...20
8192 bytes BIS M-108-20/A 0...20
2000 bytes BIS M-110-02/L 0...15
2000 bytes BIS M-111-02/L 0...20
2000 bytes BIS M-112-02/L 0...28
BIS M-301-00_-…
112 bytes BIS M-115-03/A-SA2 0...30
112 bytes BIS M-107-03/L-H200 0...28
752 bytes BIS M-101-01/L 0...34
752 bytes BIS M-102-01/L 0...45
2000 bytes BIS M-108-02/L 0...45
8192 bytes BIS M-108-20/A 0...45
2000 bytes BIS M-110-02/L 0...32
2000 bytes BIS M-111-02/L 0...45
2000 bytes BIS M-112-02/L 0...70
752 bytes BIS M-120-01/L 0...50
BIS M/VM-351-00_-…
2000 bytes BIS M-150-02/A 0...65
2000 bytes BIS M-151-02/A 0...65
112 bytes BIS M-152-03/A 0...30
2000 bytes BIS M-153-02/A 0...100
112 bytes BIS M-154-03/A 0...30
8192 bytes BIS M-155-20/A 0...65
8192 bytes BIS M-156-20/A 0...65

38
BIS M Industrial RFID System
Read/write distances overview

Memory Data carrier 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 100 120 140 160 mm


BIS M/VM-341-00_-…
2000 bytes BIS M-140-02/A-M_ 0...40
2000 bytes BIS M-112-02/L 35...90
2000 bytes BIS M-108-02/L 0...50
8192 bytes BIS M-108-20/A 0...50
2000 bytes BIS M-142-02/A-M_ 0...40
8192 bytes BIS M-142-20/A-M8 0...40
2000 bytes BIS M-143-02/A-M_ 5...21
2000 bytes BIS M-144-02/A-M_ 0...40
BIS M-401-0_ _-…
752 bytes BIS M-101-01/L 0...28
752 bytes BIS M-102-01/L 0...45 13.56 MHz HF
752 bytes BIS M-120-01/L 0...50 BIS M
2000 bytes BIS M-108-02/L 0...40 Industrial
8192 bytes BIS M-108-20/A 0...40 RFID System
2000 bytes BIS M-110-02/L 0...30 Range of
2000 bytes BIS M-111-02/L 0...40 applications
2000 bytes BIS M-112-02/L 0...60 Read/write
2000 bytes BIS M-140-02/A-M_ 0...32 distances
BIS M-451-0_ _-… overview
2000 bytes BIS M-150-02/A 0...65 Data carriers
2000 bytes BIS M-151-02/A 0...65
Read/write
112 bytes BIS M-152-03/A 0...30 heads
2000 bytes BIS M-153-02/A 0...100
Read/write
112 bytes BIS M-154-03/A 0...30 compact
8192 bytes BIS M-155-20/A 0...65 processors
8192 bytes BIS M-156-20/A 0...65 HF antenna
BIS M-410-0_ _-…
112 bytes BIS M-132-03/L 0...48 Processors
112 bytes BIS M-132-03/L-HT 0...40 Gateways
736 bytes BIS M-132-10/L 0...15 Standard
736 bytes BIS M-132-10/L-HT 0...15 handheld
2000 bytes BIS M-133-02/A 0...32 Access
736 bytes BIS M-134-10/L-HT 0...36 protection
2000 bytes BIS M-135-02/L 0...60
112 bytes BIS M-135-03/L 0...68
112 bytes BIS M-135-03/L-HT 0...20
992 bytes BIS M-135-07/L 25...45
992 bytes BIS M-135-07/L-HT 25...45
112 bytes BIS M-136-03/L 0...85
112 bytes BIS M-130-03/L 0...7
992 bytes BIS M-130-07/L 0...10
BIS M-411-0_ _-…
112 bytes BIS M-132-03/L 0...80
112 bytes BIS M-132-03/L-HT 0...70
736 bytes BIS M-132-10/L 0...26
736 bytes BIS M-132-10/L-HT 0...22
2000 bytes BIS M-133-02/A 38...52
736 bytes BIS M-134-10/L-HT 0...60
2000 bytes BIS M-135-02/L 0...100
112 bytes BIS M-135-03/L 0...110
112 bytes BIS M-135-03/L-HT 0...125
992 bytes BIS M-135-07/L 11...95
992 bytes BIS M-135-07/L-HT 11...75
112 bytes BIS M-136-03/L 0...155
992 bytes BIS M-130-07/L 0...13
BIS M-352-001-S115
2000 bytes BIS M-191-02/A 0...22
112 bytes BIS M-152-03/A 0...17
BIS M-305-001-S115
752 bytes BIS M-105-01/A 0...6
2000 bytes BIS M-105-02/A 0...8
2000 bytes BIS M-110-02/L 0...13
752 bytes BIS M-122-01/A 0...5
2000 bytes BIS M-122-02/A 0...7
2000 bytes BIS M-108-02/L 0...17
2000 bytes BIS M-140-02/A-M_ 0...15
2000 bytes BIS M-144-02/A-M_ 0...13
BIS M-307-001-S115
752 bytes BIS M-105-01/A 0...6
2000 bytes BIS M-105-02/A 0...8
2000 bytes BIS M-110-02/L 0...13
752 bytes BIS M-122-01/A 0...5
2000 bytes BIS M-122-02/A 0...7
BIS VM-306-001-S4
752 bytes BIS M-105-01/A 0...5
2000 bytes BIS M-105-02/A 0...6
112 bytes BIS M-116-03/A 0...3
2000 bytes BIS M-122-02/A 0...5
752 bytes BIS M-105-01/A 0...6

■ www.balluff.com 39
BIS M Industrial RFID System
Read/write distances overview

Memory Data carrier 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 100 120 140 160 180 200 mm


BIS VM-307-001-S4
2000 bytes BIS M-105-02/A 0...8
2000 bytes BIS M-110-02/L 0...13
752 bytes BIS M-122-01/A 0...5
2000 bytes BIS M-122-02/A 0...7
2000 bytes BIS M-140-02/A-M_ 0...15
2000 bytes BIS M-142-02/A-M_ 0...13
2000 bytes BIS M-143-02/A-M_ 0...10
2000 bytes BIS M-144-02/A-M_ 0...13
BIS VM-352-001-S4
2000 bytes BIS M-191-02/A 0...22
BIS VM-305-001-S4
752 bytes BIS M-105-01/A 0...6
2000 bytes BIS M-105-02/A 0...8
2000 bytes BIS M-110-02/L 0...13
752 bytes BIS M-122-01/A 0...5
2000 bytes BIS M-122-02/A 0...7
2000 bytes BIS M-108-02/L 0...17
8192 bytes BIS M-108-20/A 0...17
2000 bytes BIS M-140-02/A-M_ 0...15
2000 bytes BIS M-144-02/A-M_ 0...13
BIS M-402-00_-002-…
752 bytes BIS M-105-01/A 0...5
2000 bytes BIS M-105-02/A 0...5
752 bytes BIS M-122-01/A 0...5
2000 bytes BIS M-122-02/A 0...5
2000 bytes BIS M-110-02/L 0...5
112 bytes BIS M-116-03/A 0...7
160 bytes BIS M-116-08/A 0...7
BIS M-402-00_-004-…
752 bytes BIS M-105-01/A 0...5
2000 bytes BIS M-105-02/A 0...5
752 bytes BIS M-122-01/A 0...5
2000 bytes BIS M-122-02/A 0...5
2000 bytes BIS M-110-02/L 0...15
BIS M-402-00_-005-…
2000 bytes BIS M-110-02/L 0...6
BIS M-350/350-...
2000 bytes BIS M-153-02/A 0...275
2000 bytes BIS M-151-02/A 0...130
112 bytes BIS M-107-03/L-H200 0...100
112 bytes BIS M-135-03/L-HT 0...200
BIS M-450/440-…
2000 bytes BIS M-153-02/A 0...275
2000 bytes BIS M-151-02/A 0...130
112 bytes BIS M-107-03/L-H200 0...100
112 bytes BIS M-135-03/L-HT 0...200
BIS M-370-000-A02
112 bytes BIS M-132-03/L-HT 0...57
112 bytes BIS M-135-03/L 0...127
BIS M-371-000-A01
112 bytes BIS M-132-03/L 0...152
112 bytes BIS M-132-03/L-HT 0...152
112 bytes BIS M-135-03/L 0...230
112 bytes BIS M-135-03/L/HT 0...257
112 bytes BIS M-136-03/L 0...216
112 bytes BIS M-136-03/L-HT 0...254
BIS M-372-000-A01
112 bytes BIS M-132-03/L 0...216
112 bytes BIS M-132-03/L-HT 0...216
112 bytes BIS M-135-03/L 0...350
112 bytes BIS M-135-03/L-HT 0...381
112 bytes BIS M-136-03/L 0...318
112 bytes BIS M-136-03/L-HT 0...381
BIS M-373-000-A01
112 bytes BIS M-132-03/L 0...238
112 bytes BIS M-132-03/L-HT 0...228
112 bytes BIS M-135-03/L 0...380
112 bytes BIS M-135-03/L-HT 0...406
112 bytes BIS M-136-03/L 0...356
112 bytes BIS M-136-03/L-HT 0...432

40
BIS M Industrial RFID System
Read/write distances overview

13.56 MHz HF
BIS M
Industrial
RFID System
Range of
applications
Read/write
distances
overview
Data carriers
Read/write
heads
Read/write
compact
processors
HF antenna
Processors
Gateways
Standard
handheld
Access
protection

■ www.balluff.com 41
BIS M Industrial RFID System
Data carriers read/write
Circular Type

Simply attach data carrier


A single screw is enough –
and the data carrier is firmly
attached. Or simply glue it in
place.

For reliable traceability


All data carriers have a 4 or
8 byte unique ID contained in
the read/write memory.
This number is read-only. Dimensions Ø 10×4.5 mm Ø 12×6 mm
Housing material PA 12 EP
For greatest flexibility Weight < 1.5 g < 1.5 g
Data carriers in various formats
including wafer, cylinder, block BIS M read/write
or handy credit card format allow 112 bytes Ordering code
for a wide range of applications Part number
160 bytes Ordering code
Part number
752 bytes Ordering code BIS0048 BIS0040
Part number BIS M-122-01/A** BIS M-105-01/A**
992 bytes Ordering code
Part number
2000 bytes Ordering code BIS004A BIS0042
Part number BIS M-122-02/A* BIS M-105-02/A*
Operating temperature 0...+70 °C –25...+70 °C
Storage temperature –25...+85 °C –25...+85 °C
Degree of protection per IEC 60529 IP 67 IP 67

Appropriate read/write head with max. read/write distance


Mounting
BIS M-300 0...11 mm
BIS M-301
BIS M-302 0...6 mm 0...9 mm 0...6 mm 0...9 mm
BIS M-304 0...5 mm 0...7 mm 0...5 mm 0...7 mm
BIS M-402
BIS M 410
BIS M 411
BIS VM-306 0...2 mm 0...3 mm

For installation pay attention


to Basic Information chapter. Sensing Sensing
face face
Supported standard
* ISO 15693
** ISO 14443
glue into hole Ø 10 H11 glue into hole Ø 12 H11

Mounting: DIN 69873

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

42
BIS M Industrial RFID System
Data carriers read/write

13.56 MHz HF
Ø 8×5 mm Ø 8×5 mm Ø 6×1 mm Ø 20×2.5 mm
BIS M
ABS ABS EP PA 6 Industrial
0.5 g 0.5 g 0.6 g < 1.3 g RFID System
Range of
applications
Read/write
BIS00YL BIS00UC distances
overview
BIS M-130-03/L* BIS M-116-03/A*
Data carriers
BIS00UE
Read/write
BIS M-116-08/A* heads
Read/write
compact
processors
BIS00YK HF antenna
BIS M-130-07/L* Processors
BIS0044 Gateways
BIS M-110-02/L* Standard
handheld
–20...+85 °C –20...+85 °C 0...+50 °C –25...+85 °C
Access
–40...+85 °C –40...+85 °C –20...+90 °C –40...+90 °C (100 h at 140 °C) protection
IP 67 IP 67 IP 67 IP 67

0...22 mm
0...32 mm
0...16 mm
0...14 mm
0...7 mm 0...4.5 mm
0...7 mm 0...10 mm
0...13 mm
0...3 mm 0...1 mm

Ø6
Sensing Sensing Sensing Sensing
1

face face face face


5.3

5.3
Ø8

Ø8

■ www.balluff.com 43
BIS M Industrial RFID System
Data carriers read/write
Circular Type

Simply attach data carrier


A single screw is enough –
and the data carrier is firmly
attached. Or simply glue it in
place.

For reliable traceability


All data carriers have a 4 or
8 byte unique ID contained
in the read/write memory.
This number is read-only. Dimensions Ø 25×5 mm
Housing material ABS
For greatest flexibility Weight 2g
Data carriers in various formats
including wafer, cylinder, block BIS M read/write
or handy credit card format allow 112 bytes Ordering code BIS00YF
for a wide range of applications. Part number BIS M-132-03/L*
736 bytes Ordering code
Part number
752 bytes Ordering code
Part number
2000 bytes Ordering code
Part number
Operating temperature –20...+85 °C
Storage temperature –40...+85 °C
Degree of protection per IEC 60529 IP 68

Appropriate read/write head with max. read/write distance


Mounting
BIS M-300
BIS M-301
BIS M-302
BIS M-304
BIS M-410 0...48 mm
BIS M-411 0...80 mm

Bei der Montage bitte das Kapitel Grundlagen beachten.


Ø 24.9
Unterstützter Standard
Ø 3.2
* ISO 15693 Sensing
** ISO 14443 face
4.8

Montage:

Bündig in Stahl

Nichtbündig auf Stahl

Metallfrei

Antennentyp:

Stab

Rund

44
BIS M Industrial RFID System
Data carriers read/write

13.56 MHz HF
Ø 25×5 mm Ø 30×10 mm Ø 30×1.6 mm Ø 30×2.5 mm
BIS M
ABS PA EP PA 6 Industrial
3g 10 g < 1.6 g <3g RFID System
Range of
applications
Read/write
distances
overview
Data carriers
BIS00YC
Read/write
BIS M-132-10/L** heads
BIS003Y Read/write
compact
BIS M-101-01/L** processors
BIS00Y9 BIS0045 HF antenna
BIS M-133-02/A* BIS M-111-02/L* Processors
–20...+85 °C –40...+85 °C –25...+70 °C –25...+85 °C Gateways
–40...+85 °C –40...+85 °C –40...+85 °C –40...+90 °C (100 h at 140 °C) Standard
handheld
IP 68 IP 67 IP 67 IP 67
Access
protection

0...22 mm 0...28 mm
0...34 mm 0...45 mm
0...16 mm 0...20 mm
0...14 mm
0...15 mm 0...32 mm
0...26 mm 38...52 mm

Ø 24.9 Ø 30
Ø 3.2 Ø 6.5
Sensing Sensing Sensing Sensing
face face face face
4.8

8.9

Ø 3.2

Tightening torque max. 0.75 Nm Tightening torque max. 1 Nm Tightening torque max. 1 Nm

■ www.balluff.com 45
BIS M Industrial RFID System
Data carriers read/write
Circular Type

For greatest flexibility


Data carriers in various formats including wafer, cylinder, block
or handy credit card format allow for a wide range of applications

For reliable traceability


All data carriers have a 4-byte unique ID contained in
the read/write memory. This number is read-only.

Dimensions
Housing material
Weight

BIS M read/write
752 bytes Ordering code
Part number
2000 bytes Ordering code
Part number
Operating temperature
Storage temperature
Degree of protection per IEC 60529

Appropriate read/write head with max. read/write distance


Mounting
BIS M-300
BIS M-301
BIS M-302
BIS M-304

For installation pay attention to Basic Information chapter.

Supported standard
* ISO 15693
** ISO 14443

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

46
BIS M Industrial RFID System
Data carriers read/write

13.56 MHz HF
Ø 50×1.6 mm 50×3 mm
BIS M
EP PA 6 Industrial
< 2.5 g < 9.5 g RFID System
Range of
applications
Read/write
BIS003Z distances
overview
BIS M-102-01/L**
Data carriers
BIS0046
Read/write
BIS M-112-02/L* heads
–25...+70 °C –25...+85 °C Read/write
compact
–25...+85 °C –40...+90 °C (100 h at 140 °C) processors
IP 67 IP 67 HF antenna
Processors
Gateways
Standard
handheld
0...32 mm 0...44 mm
Access
0...45 mm 0...70 mm protection
0...20 mm 0...30 mm
0...18 mm

Sensing Sensing
face face

Tightening torque max. 2.5 Nm Tightening torque max. 5.9 Nm

■ www.balluff.com 47
BIS M Industrial RFID System
Data carriers read/write
Rectangular Type

For greatest flexibility


Data carriers in various formats including wafer, cylinder, block or
handy credit card format allow for a wide range of applications

For reliable traceability


All data carriers have a 4-byte unique ID contained in the read/write
memory. This number is read-only.

Dimensions
Housing material
Weight

BIS M read/write
112 bytes Ordering code
Part number
992 bytes Ordering code
Part number
2000 bytes Ordering code
Part number
Operating temperature
Storage temperature
Degree of protection per IEC 60529

Appropriate read/write head with max. read/write distance


Mounting
BIS M-410
BIS M-411

For installation pay attention to Basic Information chapter.

Supported standard
*ISO 15693

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

48
BIS M Industrial RFID System
Data carriers read/write

13.56 MHz HF
51.5×51.5×6.5 mm 51.5×51.5×6.5 mm 51.5×51.5×6.5 mm
BIS M
ABS ABS ABS Industrial
18 g 25 g 25 g RFID System
Range of
applications
Read/write
BIS00Y5 distances
overview
BIS M-135-03/L*
Data carriers
BIS00Y3
Read/write
BIS M-135-07/L* heads
BIS00Y6 Read/write
compact
BIS M-135-02/L* processors
–40...+85 °C –55...+85 °C –40...+85 °C HF antenna
–40...+85 °C –55...+140 °C –40...+125 °C Processors
IP 67 IP 67 IP 67 Gateways
Standard
handheld
Access
protection
0...60 mm 0...68 mm 23...46 mm
0...100 mm 0...110 mm 11...95 mm

Ø 10.5 Ø 10.5 Ø 10.5


Ø 5.5 Ø 5.5 Ø 5.5
6.5

6.5

6.5
51

51

51

51 51 51

■ www.balluff.com 49
BIS M Industrial RFID System
Data carriers read/write
Rectangular Type

For greatest flexibility


Data carriers in various formats
including wafer, cylinder, block
or handy credit card format allow
for a wide range of applications

For reliable traceability


All data carriers have a 4-byte
unique ID contained in the read/
write memory. This number is
read-only. Dimensions 52×32×11
32 11 mm
Housing material PBT
Weight < 27 g

BIS M read/write
112 bytes Ordering code
Part number
752 bytes Ordering code
Part number
2000 bytes Ordering code BIS0043
Part number BIS M-108-02/L*
8192 bytes Ordering code BIS0111
(only with BIS VM units) Part number BIS M-108-20/A*
Operating temperature –25...+70 °C
Storage temperature –25...+85 °C
Degree of protection per IEC 60529 IP 67

Appropriate read/write head with max. read/write distance


Mounting
BIS M-300, BIS VM-300 0...16 mm 0...30 mm
BIS M-301, BIS VM-301 0...45 mm
BIS M-302 0...12 mm 0...20 mm
BIS M-304 0...10 mm 0...18 mm
BIS M-410
BIS M-411

For installation pay attention to Basic Information chapter.


Sensing
Supported standard face
* ISO 15693
** ISO 14443

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

50
BIS M Industrial RFID System
Data carriers read/write

without
with adhesive adhesive
13.56 MHz HF
128×52×11 mm 65×25×3 mm 65×25×3 mm 85.6×54×0.76 mm
BIS M
ABS EP, PVC EP, PVC PVC Industrial
46 g 7g 7g < 5.8 g RFID System
Range of
applications
Read/write
BIS00W9 BIS00KM BIS00RZ distances
overview
BIS M-136-03/L* BIS M-115-03/A* BIS M-115-03/A-SA2*
Data carriers
BIS0047
Read/write
BIS M-120-01/L** heads
Read/write
compact
processors
HF antenna
Processors
–20...+85 °C –25...+50 °C –25...+50 °C –25...+70 °C Gateways
–40...+85 °C –30...+60 °C –30...+60 °C –25...+70 °C Standard
handheld
IP 67 IP 65 IP 65 IP 67
Access
protection

0...18 mm 0...22 mm 0...18 mm 0...22 mm


0...30 mm 0...38 mm 0...30 mm 0...38 mm 0...50 mm

0...85 mm
0...155 mm
3

Sensing face
Sensing
Sensing face face
25

65

■ www.balluff.com 51
BIS M Industrial RFID System
Data carriers read/write
Specialty Type

For greatest flexibility


Data carriers in various formats including wafer, cylinder, block
or handy credit card format allow for a wide range of applications

For reliable traceability


All data carriers have a 4-byte unique ID contained in
the read/write memory. This number is read-only.

Dimensions
Housing material
Weight

BIS M read/write
112 bytes Ordering code
Part number
752 bytes Ordering code
Part number
2000 bytes Ordering code
Part number
Operating temperature
Storage temperature
Degree of protection per IEC 60529

Appropriate read/write head with max. read/write distance


Mounting
BIS M-304
BIS M-351
BIS M-352
BIS M-451

For installation pay attention to Basic Information chapter.

Supported standard
* ISO 15693
** ISO 14443

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

52
BIS M Industrial RFID System
Data carriers read/write

FERROIDENT FERROIDENT FERROIDENT


13.56 MHz HF
4×22 mm Ø 8×35 mm 24×24×21 mm Ø 15×50 mm
BIS M
Glass PA 66 (fiberglass reinforced) PBT POM, PA 12 Industrial
0.6 g 2g 18 g 12 g RFID System
Range of
applications
Read/write
BIS00M2 BIS00P1 distances
overview
BIS M-152-03/A* BIS M-154-03/A*
Data carriers
BIS0049
Read/write
BIS M-122-01/A-ZC1** heads
BIS00NZ BIS004C Read/write
compact
BIS M-191-02/A* BIS M-122-02/A-ZC1* processors
–25...+85 °C –25...+85 °C –25...+70 °C –25...+70 °C HF antenna
–25...+85 °C –25...+85 °C –25...+85 °C –25...+85 °C Processors
IP 67 IP 67 IP 67 IP 67 Gateways
Standard
handheld
Access
protection
0...5 mm
0...30 mm 0...30 mm
0...10 mm 0...17 mm 0...10 mm 0...14 mm
0...30 mm 0...30 mm

Ø 3.1 Sensing
Ø4 Ø8
Ø 3.1 face
8
22.2

6
27.5
35

Ø 4.5

24

Ø7
15

24
4
4

4
4
15

■ www.balluff.com 53
BIS M Industrial RFID System
Data carriers read/write
DATABOLT™

Dimensions M6
Housing material Steel coated,
PA 12 (fiberglass reinforced)
Weight 12 g

BIS M read/write
2000 bytes Ordering code BIS00T1
Part number BIS M-122-02/A-SA2*
8192 bytes Ordering code
(only with BIS VM units) Part number
Operating temperature –25...+70 °C
Storage temperature –25...+95 °C
Degree of protection per IEC 60529/DIN 40050 IP 68/x9K

Appropriate read/write head with max. read/write distance


Mounting
BIS M-300, BIS VM-300
BIS M-302
BIS M-304 0...5 mm
BIS VM-307
BIS M-341, BIS VM-341

For installation pay attention to Basic Information chapter.


Ø10
Supported standard
*ISO 15693
Sensing
13 face
Mounting:
7.5

0.2

flush in steel

non-flush on steel
+ 0.20
- 0.10
10

10

non-metal
M6
Ø15
Antenna type:
9.5 Nm
rod

round

54
BIS M Industrial RFID System
Data carriers read/write

13.56 MHz HF
M6 M8 M6 M8
Range of
Steel coated, Steel coated, Steel coated, Steel coated, applications
PA 12 (fiberglass reinforced) PA 12 (fiberglass reinforced) PA 12 (fiberglass reinforced) PA 12 (fiberglass reinforced) Data carriers
read/write
17 g 18 g 15 g 16 g
Read/write
heads
Read/write
BIS00NU BIS00NW BIS00PT BIS00PU compact
processors
BIS M-143-02/A-M6* BIS M-143-02/A-M8* BIS M-142-02/A-M6-GY* BIS M-142-02/A-M8-GY* HF antenna
BIS0119 HF antenna
BIS M-142-20/A-M8-GY* compact
processor
–25...+70 °C –25...+70 °C –25...+70 °C –25...+70 °C
HF long range
–25...+95 °C –25...+95 °C –25...+95 °C –25...+95 °C processors
IP 68/x9K IP 68/x9K IP 68/x9K IP 68/x9K HF long range
conveyor
antenna
HF long range
antenna
0...14 mm 0...14 mm Processors
0...10 mm 0...10 mm 0...14 mm 0...14 mm Gateways
Standard
handheld
0...10 mm 0...10 mm 0...13 mm 0...13 mm Access
5...21 mm 5...21 mm 0...40 mm 0...40 mm protection

Ø10 Ø13 Ø10 Ø13

Sensing Sensing
Sensing
Sensing 19 face 19 face
face
19 19 face
7.5

0.2
7.5

11 0.2
0.2

7.5

0.2
7.5

+0.2
10 -0.1
0.60
15 -0.25

11

+0.60
15 - 0.25
11

+0.2
10 - 0.1
11

+0.4
10 - 0.1
+0.4
10 - 0.1

M6 M6 M8
M8 Ø22
Ø22 Ø22
Ø22

9.5 Nm 23 Nm 9.5 Nm 23 Nm

■ www.balluff.com 55
BIS M Industrial RFID System
Data carriers read/write
DATABOLT™

Dimensions
Housing material

Weight

BIS M read/write
2000 bytes Ordering code
Part number
Operating temperature
Storage temperature
Degree of protection per IEC 60529/DIN 40050

Appropriate read/write head with max. read/write distance


Mounting
BIS M-300, BIS VM-300
BIS M-302
BIS M-305, BIS VM-305
BIS VM-307
BIS M-341, BIS VM-341
BIS M-401

For installation pay attention to Basic Information chapter.

Supported standard
*ISO 15693

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

56
BIS M Industrial RFID System
Data carriers read/write

13.56 MHz HF
M6 M8 M6 M8
BIS M
Steel coated, Steel coated, Steel coated, Steel coated, Industrial
PA 12 (fiberglass reinforced) PA 12 (fiberglass reinforced) PA 12 (fiberglass reinforced) PA 12 (fiberglass reinforced) RFID System
17 g 18 g 16 g 17 g Range of
applications
Read/write
distances
overview
BIS00M9 BIS00M8 BIS00R4 BIS00R5
Data carriers
BIS M-140-02/A-M6* BIS M-140-02/A-M8* BIS M-144-02/A-M6-GY* BIS M-144-02/A-M8-GY*
Read/write
–25...+70 °C –25...+70 °C –25...+70 °C –25...+70 °C heads
–25...+95 °C –25...+95 °C –25...+95 °C –25...+95 °C Read/write
compact
IP 68/x9K IP 68/x9K IP 68/x9K IP 68/x9K processors
HF antenna
Processors
Gateways
0...20 mm 0...20 mm 0...17 mm 0...17 mm Standard
handheld
0...14 mm 0...14 mm 0...14 mm 0...14 mm
Access
0...15 mm 0...15 mm 0...13 mm 0...13 mm protection
0...15 mm 0...15 mm 0...13 mm 0...13 mm
0...40 mm 0...40 mm
0...32 mm 0...32 mm

Ø10 Ø13 Ø10 Ø13

Sensing Sensing Sensing


Sensing
19 face 19 face 19 19 face
face
12.7

12.7
0.2

0.2
7.5

0.2

7.5

0.2

- 0.1

+ 0.2
+ 0.2

15.2 - 0.1
11
11
11

11

+0.60
- 0.25
+0.2
10 - 0.1
+0.60
20 - 0.25

10 +- 0.1
0.2

15.2

M8
M6
20

M6 M8
Ø22 Ø22 Ø22
Ø22

9.5 Nm 23 Nm 9.5 Nm
23 Nm

■ www.balluff.com 57
BIS M Industrial RFID System
Data carriers read/write – mount on steel
FERROIDENT

For maximum data security


in all environments – even on
metal!

For reliable traceability


All data carriers have a 4-byte
unique ID contained in the read/
write memory. This number is
read-only.

Dimensions 40×22×6.5 mm
Housing material PPS (fiberglass reinforced)
Weight 8g

BIS M read/write
2000 bytes Ordering code BIS004F
Part number BIS M-150-02/A*
8192 bytes Ordering code
(only with BIS VM units) Part number
Operating temperature –25...+70 °C
Storage temperature –25...+130 °C
Degree of protection per IEC 60529 IP 67

Appropriate read/write head with max. read/write distance


Mounting
BIS M-350 0...130 mm
BIS M-351 0...65 mm
BIS M-450 0...130 mm
BIS M-451 0...65 mm

For installation pay attention


to Basic Information chapter.

Supported standard
*ISO 15693

Mounting:

flush in steel

non-flush on steel
Direction
non-metal of detection

Antenna type:

rod

round

Recommended accessories
(please order separately)

Description Metal mounting plate 40×22 mm


Ordering code BAM012M
Part number BIS Z-MP-001
Required if no metal substrate is used. (10 to a package)

58
BIS M Industrial RFID System
Data carriers read/write – mount on steel

13.56 MHz HF
40×22×6.5 mm 40×22×9.5 mm 40×22×9.5 mm 80×40×22 mm
BIS M
PPS (fiberglass reinforced) PPS (fiberglass reinforced) PPS (fiberglass reinforced) POM Industrial
8g 9g 9g 95 g RFID System
Range of
applications
Read/write
BIS004H BIS00P3 distances
overview
BIS M-151-02/A* BIS M-153-02/A*
Data carriers
BIS0117 BIS0112 BIS010R
Read/write
BIS M-155-20/A* BIS M-156-20/A* BIS M-153-20/A* heads
–25...+70 °C –25...+70 °C –25...+70 °C –25...+85 °C Read/write
compact
–25...+130 °C –25...+130 °C –25...+130 °C –25...+85 °C processors
IP 67 IP 67 IP 67 IP 68 HF antenna
Processors
Gateways
Standard
handheld
0...130 mm 0...130 mm 0...130 mm 0...275 mm 0...90 mm
Access
0...65 mm 0...65 mm 0...65 mm 0...100 mm protection
0...130 mm 0...130 mm 0...130 mm 0...275 mm
0...65 mm 0...65 mm 0...65 mm 0...100 mm

9.5
9.5
1.7 Direction of detection 5.3
1.7

4.3

40
3 Nm

5.8 61
22 70
Direction Direction 80
of detection of detection
Direction
of detection

■ www.balluff.com 59
BIS M Industrial RFID System
Data carriers read/write
High Temperature

Dimensions Ø 25×5 mm Ø 25×5 mm Ø 50×5 mm


Housing material PPS PPS PPS
Weight 4g 4g 17 g

BIS M read/write
112 bytes Ordering code BIS00YE
Part number BIS M-132-03/L-HT*
736 bytes Ordering code BIS00YA BIS00Y7
Part number BIS M-132-10/L-HT** BIS M-134-10/L-HT**
992 bytes Ordering code
Part number
Operating temperature –40...+93 °C –40...+93 °C –40...+93 °C
Storage temperature –40...+220 °C –40...+220 °C –40...+220 °C
Storage temperature extended
Degree of protection per IEC 60529 IP 67 IP 67 IP 67

Appropriate read/write head with max. read/write distance


Mounting
BIS M-300, BIS VM-300
BIS M-301, BIS VM-301
BIS M-410 0...40 mm 0...15 mm 0...36 mm
BIS M-411 0...70 mm 0...22 mm 0...60 mm

For installation pay attention to Basic Information chapter.


Ø 24.9 Ø 24.9
Supported standard Ø 50
Ø 3.2 Ø 3.2
* ISO 15693 Sensing Sensing Sensing Ø 4.9
** ISO 14443 face face face
4.8

4.8

5.3
Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

60
BIS M Industrial RFID System
Data carriers read/write

13.56 MHz HF
51.5×51.5×6.5 mm 51.5×51.5×6.5 mm 40×22×6.5 mm 128×52×11 mm
BIS M
PPS PPS PPS (fiberglass reinforced) PPS Industrial
25 g 25 g 6g 68 g RFID System
Range of
applications
Read/write
BIS00Y4 BIS00LC BIS00Y1 distances
overview
BIS M-135-03/L-HT* BIS M-107-03/L-H200* BIS M-136-03/L-HT*
Data carriers
Read/write
heads
BIS00Y2 Read/write
compact
BIS M-135-07/L-HT* processors
–40...+93 °C –40...+93 °C –25...+70 °C –40...+93 °C HF antenna
–40...+220 °C –40...+220 °C –25...+85 °C –40...+220 °C Processors
200 °C (1000 h tested) Gateways
IP 67 IP 67 IP 68/x9K IP 67 Standard
handheld
Access
protection

0...18 mm
0...28 mm
0...70 mm 23...46 mm 0...185 mm
0...125 mm 11...75 mm

Ø 10.5 Ø 10.5
Ø 5.5 Ø 5.5
6.5

6.5

Sensing face
6.5

4.2 1.7
Sensing face
3.2

22
51

51

30
32
40
51 51

■ www.balluff.com 61
BIS M Industrial RFID System
Read/write heads

Small size – big performance


Read/write heads in various form factors offer wide application
possibilities. Simply choose according to your application.

Dimensions
Housing material
For standard processors Ordering code
(up to 2 kByte) Part number
For BIS M-407 processors Ordering code
(up to 2 kByte) Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection to
Connection cable

Appropriate data carrier


Installation note for data carriers Data carrier to metal distance in mm
Data carrier clear zone in mm
Clear zone

Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
5 mm
9 mm
Distance to metal 12 mm
15 mm
16 mm
18 mm
20 mm
22 mm
25 mm
30 mm

For installation pay attention to Basic Information chapter.

* For use only with processor BIS M-407-039-06-S115!

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

62
BIS M Industrial RFID System
Read/write heads

13.56 MHz HF
M18×1
BIS M
Brass, coated Industrial
BIS0057 RFID System
BIS M-302-001-S115 Range of
applications
BIS0059 Read/write
BIS M-302-003-S115* distances
overview
Data carriers
0...+70 °C
Read/write
–20...+85 °C heads
IP 67 Read/write
compact
Processor processors
See page 380 for cable options HF antenna
Processors
Gateways

BIS M-140-02/A-M_

BIS M-142-02/A-M_

BIS M-143-02/A-M_

BIS M-144-02/A-M_
see data carriers

see data carriers

see data carriers

see data carriers


Standard
BIS M-105-01/A

BIS M-105-02/A

BIS M-122-01/A

BIS M-122-02/A
BIS M-101-01/L

BIS M-102-01/L

BIS M-108-02/L

BIS M-110-02/L

BIS M-111-02/L

BIS M-112-02/L
handheld
Access
protection
BIS004A
BIS003Y

BIS003Z

BIS0040

BIS0042

BIS0048

BIS0043

BIS0044

BIS0045

BIS0046

> 25 > 5 > 50 > 10 > 10 >0 > 10 >0 > 10 >0 > 10 >0 > 25 >0 > 25 > 5 > 25 > 5 > 50 > 20 >0 >0 >0 >0
> 60 > 50 > 60 > 50 > 60 >0 > 60 >0 > 60 >0 > 60 >0 > 60 >0 > 80 > 50 > 80 > 50 > 150 > 70 > 100 > 100 > 100 > 100

0...16 0...10 0...20 0...10 0...7 0...5 0...9 0...6 0...7 0...5 0...9 0...6 0...20 0...12 0...16 0...8 0...20 0...5 0...30 0...12 0...14 0...14 0...10 0...14
0...16 0...10 0...20 0...10 0...7 0...5 0...9 0...6 0...7 0...5 0...9 0...6 0...20 0...12 0...16 0...8 0...20 0...5 0...30 0...12 0...14 0...14 0...10 0...14
±10 ±4 ±18 ±8 ±5 ±4 ±5 ±5 ±4 ±3 ±4 ±3 ±14 ±10 ±8 ±4 ±12 ±7 ±20 ±14 ±8 ±8 ±5 ±6
±10 ±4 ±18 ±6 ±4 ±3 ±5 ±3.5 ±3 ±2 ±3 ±2 ±12 ±8 ±8 ±4 ±12 ±4 ±20 ±14 ±8 ±8 ±5 ±6
±10 ±2 ±16 ±4 ±3.5 ±12 ±6 ±6 ±10 ±18 ±10 ±8 ±8 ±3 ±6
±8 ±14 ±10 ±4 ±4 ±10 ±18 ±6 ±8 ±8 ±6
±7 ±12 ±10 ±4 ±10 ±18
±4 ±10 ±7 ±3 ±5 ±16
±8 ±7 ±5 ±16
±4 ±5 ±5 ±16
±12
±12
±8

Sensing face

■ www.balluff.com 63
BIS M Industrial RFID System
Read/write heads

M18 housing with extra small read/write head:


just 14mm provides security (in tool identification, for example).

Dimensions
Housing material
For standard processors Ordering code
(up to 2 kByte) Part number
For BIS M-407 processors Ordering code
(up to 2 kByte) Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection to
Connection cable

Appropriate data carrier


Installation note for data carriers Data carrier to metal distance in mm
Data carrier clear zone in mm
Clear zone

Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
5 mm
9 mm
Distance to metal 12 mm
15 mm
16 mm
18 mm

For installation pay attention to Basic Information chapter.

* For use only with processor BIS M-407-039-06-S115!

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

64
BIS M Industrial RFID System
Read/write heads

13.56 MHz HF
M18×1
BIS M
Brass, coated Industrial
BIS005A RFID System
BIS M-304-001-S115 Range of
applications
BIS008P Read/write
BIS M-304-003-S115* distances
overview
Data carriers
0...+70 °C
Read/write
–20...+85 °C heads
IP 67 Read/write
compact
Processor processors
See page 380 for cable options HF antenna
Processors

BIS M-122-02/A-SA2
Gateways
Standard
BIS M-105-01/A

BIS M-105-02/A

BIS M-122-01/A

BIS M-122-02/A
BIS M-101-01/L

BIS M-102-01/L

BIS M-108-02/L

BIS M-110-02/L

handheld
Access
protection
BIS004A
BIS003Y

BIS003Z

BIS00T1
BIS0040

BIS0042

BIS0048

BIS0043

BIS0044

> 25 > 5 > 50 > 10 > 10 >0 > 10 >0 > 10 >0 > 10 >0 > 25 >0 > 25 > 5 >0
> 60 > 50 > 60 > 50 > 60 >0 > 60 >0 > 60 >0 > 60 >0 > 60 >0 > 80 > 50 >0

0...14 0...8 0...18 0...10 0...5 0...5 0...7 0...6 0...5 0...4 0...7 0...5 0...18 0...10 0...14 0...8 0...5
0...14 0...8 0...18 0...10 0...5 0...5 0...7 0...6 0...5 0...4 0...7 0...5 0...18 0...10 0...14 0...8 0...5
±10 ±4 ±18 ±8 ±5 ±4 ±5 ±5 ±4 ±2 ±4 ±3 ±14 ±10 ±8 ±4 ±3
±10 ±4 ±18 ±6 ±4 ±3 ±5 ±3.5 ±3 ±3 ±2 ±12 ±8 ±8 ±4 ±2
±10 ±16 ±4 ±3 ±12 ±6 ±6
±8 ±14 ±10 ±4
±12 ±10
±10 ±7
±8 ±5

Sensing face

■ www.balluff.com 65
BIS M Industrial RFID System
Read/write heads

The large diameter of these tubular read/write heads


enables generous distances to the object.

Dimensions
Housing material
For standard processor Ordering code
(up to 2 kByte) Part number
For BIS M-407 processor Ordering code
(up to 2 kByte) Part number
For BIS V processor Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection to
Connection cable

Appropriate data carrier


Installation note for data carriers Data carrier to metal distance in mm
Data carrier clear zone in mm
Clear zone

Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
5 mm
9 mm
Distance to metal 12 mm
15 mm
16 mm
18 mm
20 mm
22 mm
25 mm
30 mm
32 mm
35 mm
40 mm
43 mm

For installation pay attention to Basic Information chapter.

* For use only with processor BIS M-407-039-06-S115!

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

66 round
BIS M Industrial RFID System
Read/write heads

13.56 MHz HF
M30×1.5
BIS M
Brass, coated Industrial
BIS0053 RFID System
BIS M-300-001-S115 Range of
applications
BIS0054 Read/write
BIS M-300-003-S115* distances
overview
BIS00RF
Data carriers
BIS VM-300-001-S4
Read/write
heads
0...+70 °C Read/write
compact
–20...+85 °C processors
IP 67 HF antenna
Processor Processors
See page 380 for cable options Gateways
Standard
handheld
BIS M-115-03/A-SA2

BIS M-102-03/L-H200
BIS M-140-02/A-M6

BIS M-143-02/A-M6

BIS M-143-02/A-M8

BIS M-144-02/A-M6

BIS M-144-02/A-M8
Access
protection
BIS M-105-01/A

BIS M-105-02/A

BIS M-108-20/A
BIS M-101-01/L

BIS M-102-01/L

BIS M-108-02/L

BIS M-110-02/L

BIS M-111-02/L

BIS M-112-02/L

BIS00NW
BIS00NU
BIS00M9
BIS00RZ

BIS00LC
BIS00R4

BIS00R5
BIS003Y

BIS003Z

BIS0040

BIS0042

BIS0043

BIS0111

BIS0044

BIS0045

BIS0046

>0 > 25 > 5 > 50 > 10 > 20 > 5 > 20 > 5 > 25 > 0 > 25 > 0 > 25 > 5 > 25 > 5 > 50 > 10 >0 >0 >0 >0 >0 > 20
> 50 >100 > 50 > 150 > 70 >100 >100 >100 >100 >100 > 0 >100 > 0 >100 > 50 >100 > 50 >150 > 70 > 100 > 100 > 100 > 100 > 100 > 110

0...18 0...22 0...15 0...32 0...12 0...9 0...9 0...11 0...11 0...30 0...16 0...30 0...16 0...22 0...10 0...28 0...10 0...44 0...15 0...20 0...14 0...14 0...17 0...17 0...18
0...18 0...22 0...15 0...32 0...12 0...9 0...9 0...11 0...11 0...30 0...16 0...30 0...16 0...22 0...10 0...28 0...10 0...44 0...15 0...20 0...14 0...14 0...17 0...17 0...18
±14 ±15 ±8 ±20 ±6 ±7 ±6 ±10 ±7 ±18 ±10 ±18 ±10 ±14 ±7 ±16 ±7 ±25 ±15 ±12 ±9 ±9 ±12 ±12 ±15
±14 ±15 ±8 ±20 ±6 ±7 ±6 ±8 ±7 ±18 ±10 ±18 ±10 ±14 ±7 ±16 ±7 ±25 ±15 ±12 ±9 ±9 ±12 ±12 ±12
±14 ±15 ±6 ±20 ±5 ±2 ±1 ±5 ±3 ±18 ±8 ±18 ±8 ±12 ±2 ±14 ±2 ±25 ±12 ±12 ±9 ±9 ±12 ±12 ±12
±14 ±15 ±4 ±20 ±4 ±16 ±6 ±16 ±6 ±12 ±14 ±24 ±10 ±12 ±6 ±6 ±8 ±8 ±10
±14 ±15 ±4 ±20 ±16 ±6 ±16 ±6 ±12 ±14 ±24 ±8 ±12 ±8 ±8 ±7
±14 ±12 ±20 ±16 ±4 ±16 ±4 ±10 ±14 ±24 ±7 ±8 ±8 ±5
±10 ±12 ±20 ±16 ±16 ±10 ±14 ±24 ±7 ±5
±12 ±20 ±16 ±16 ±10 ±14 ±24 ±7
±4 ±18 ±14 ±14 ±6 ±12 ±22
±14 ±14 ±14 ±12 ±22
±10 ±22
±4 ±16
±16
±16
±10

BIS M-300 BIS VM-300 M30x1.5


Sensing face
LED
13

36
37.5
70.5
10

M12x1

■ www.balluff.com 67
BIS M Industrial RFID System
Read/write compact processors
Serial
and IO-Link
For longer ranges
Integrated version of read/write head with processor in
large form factor. For direct connection to the controller.

Dimensions
Housing material
Serial, RS232 Ordering code
(up to 2 kByte) Part number
IO-Link, 10 byte Ordering code
Part number
IO-Link, 32 byte Ordering code
Part number
Mounting
Supply voltage
Current
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection type
Accessories included
Connection cable

Appropriate data carrier (common for both heads)


Installation note for data carriers Data carrier to metal distance in mm
Data carrier clear zone in mm
Clear zone

Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
5 mm
9 mm
Distance to metal 12 mm
15 mm
16 mm
18 mm
20 mm
22 mm
25 mm
30 mm
32 mm
35 mm

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

68
BIS M Industrial RFID System
Read/write compact processors

13.56 MHz HF
M30×1.5 M30×1.5
BIS M
Brass, coated Brass, coated Industrial
BIS00EJ RFID System
BIS M-400-007-001-00-S115 Range of
applications
BIS00LH Read/write
BIS M-400-045-001-07-S4 distances
overview
BIS0108
Data carriers
BIS M-400-072-001-07-S4
Read/write
heads
24 V DC +10 %/–20 % including ripple 24 V DC +10 %/–20 % including ripple Read/write
compact
≤ 50 mA no-load ≤ 150 mA processors
0...+70 °C 0...+70 °C HF antenna
–20...+85 °C –20...+85 °C Processors
IP 67 IP 67 Gateways
1× M12 connector male, 8-pin 1× M12 connector male, 4-pin Standard
handheld
Configuration software Configuration software
Access
See page 388 for cable options See page 374 for cable options protection
BIS M-105-01/A

BIS M-105-02/A

BIS M-108-20/A
BIS M-101-01/L

BIS M-102-01/L

BIS M-108-02/L

BIS M-110-02/L

BIS M-111-02/L

BIS M-112-02/L
BIS003Y

BIS003Z

BIS0040

BIS0042

BIS0043

BIS0111

BIS0044

BIS0045

BIS0046

> 25 > 5 > 50 > 10 > 20 > 5 > 20 > 5 > 25 > 0 > 25 > 0 > 25 > 5 > 25 > 5 > 50 > 10
> 100 > 50 > 150 > 70 > 100 > 100 > 100 > 100 > 100 > 0 > 100 > 0 > 100 > 50 > 100 > 60 > 150 > 70

0...20 0...12 0...28 0...12 0...7 0...6 0...11 0...7 0...28 0...16 0...28 0...16 0...20 0...8 0...28 0...10 0...38 0...15
0...20 0...12 0...28 0...12 0...7 0...6 0...11 0...7 0...28 0...16 0...28 0...16 0...20 0...8 0...28 0...10 0...38 0...15
±14 ±6 ±20 ±6 ±7 ±6 ±9 ±6 ±16 ±10 ±16 ±10 ±12 ±6 ±16 ±7 ±22 ±13
±14 ±6 ±20 ±6 ±7 ±6 ±8 ±6 ±16 ±10 ±16 ±10 ±12 ±5 ±16 ±7 ±22 ±13
±14 ±4 ±20 ±3 ±5 ±14 ±8 ±14 ±8 ±10 ±14 ±2 ±22 ±10
±10 ±2 ±20 ±2 ±14 ±6 ±14 ±6 ±8 ±14 ±20 ±8
±10 ±20 ±14 ±6 ±14 ±6 ±8 ±14 ±20 ±6
±8 ±18 ±14 ±4 ±14 ±4 ±5 ±14 ±20
±6 ±16 ±14 ±14 ±5 ±14 ±20
±5 ±15 ±14 ±14 ±5 ±14 ±20
±15 ±12 ±12 ±12 ±20
±10 ±12 ±12 ±12 ±20
±16
±10
±10

Sensing face

■ www.balluff.com 69
BIS M Industrial RFID System
Read/write compact processors
Serial
and IO-Link
For direct connection to the controller
for tight space conditions

Dimensions
Housing material
Serial, RS232 Ordering code
(up to 2 kByte) Part number
IO-Link, 10 byte Ordering code
Part number
IO-Link, 32 byte Ordering code
Part number
Mounting
Supply voltage
Current
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection type
Accessories included
Connection cable

Appropriate data carrier (common for both heads)


Installation note for data carriers Data carrier to metal distance in mm
Data carrier clear zone in mm
Clear zone

Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
5 mm
9 mm
Distance to metal 12 mm
15 mm
16 mm
18 mm
20 mm
22 mm
25 mm

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

70
BIS M Industrial RFID System
Read/write compact processors

13.56 MHz HF
M30×1.5 M30×1.5
BIS M
Brass, coated Brass, coated Industrial
BIS00EK RFID System
BIS M-400-007-002-00-S115 Range of
applications
BIS00LJ Read/write
BIS M-400-045-002-07-S4 distances
overview
BIS0104
Data carriers
BIS M-400-072-002-07-S4
Read/write
heads
24 V DC +10 %/–20 % including ripple 18…30 V DC Read/write
compact
≤ 50 mA no-load draw at 24 V DC ≤ 150 mA, load ≤ 50 mA processors
0...+70 °C 0...+70 °C HF antenna
–20...+85 °C –20...+85 °C Processors
IP 67 P 67 Gateways
1× M12 connector male, 8-pin 1× M12 connector male, 4-pin Standard
handheld
Configuration software
Access
See page 388 for cable options See page 374 for cable options protection
BIS M-105-01/A

BIS M-105-02/A

BIS M-122-01/A

BIS M-122-02/A

BIS M-108-20/A
BIS M-101-01/L

BIS M-102-01/L

BIS M-108-02/L

BIS M-110-02/L

BIS M-111-02/L

BIS M-112-02/L
BIS004A
BIS003Y

BIS003Z

BIS0040

BIS0042

BIS0048

BIS0043

BIS0111

BIS0044

BIS0045

BIS0046

> 25 > 5 > 50 > 10 > 10 > 0 > 10 > 0 > 10 > 0 > 10 > 0 > 25 > 0 > 25 > 0 > 25 > 5 > 25 > 5 > 50 > 20
> 60 > 50 > 60 > 50 > 60 > 0 > 60 > 0 > 60 > 0 > 60 > 0 > 60 > 0 > 60 > 0 > 80 > 50 > 80 > 50 > 150 > 70

0...15 0...9 0...18 0...10 0...6 0...5 0...9 0...5 0...5 0...4 0...6 0...5 0...20 0...12 0...20 0...12 0...15 0...6 0...20 0...5 0...28 0...10
0...15 0...9 0...18 0...10 0...6 0...5 0...9 0...5 0...5 0...4 0...6 0...5 0...20 0...12 0...20 0...12 0...15 0...6 0...20 0...5 0...28 0...10
±9 ±4 ±16 ±4 ±5 ±4 ±6 ±4 ±4 ±3 ±4 ±3 ±14 ±10 ±14 ±10 ±8 ±4 ±12 ±7 ±20 ±14
±9 ±4 ±16 ±4 ±4 ±2 ±6 ±2 ±3 ±3 ±2 ±14 ±8 ±14 ±8 ±8 ±4 ±12 ±4 ±20 ±14
±8 ±2 ±12 ±2 ±2 ±12 ±6 ±12 ±6 ±6 ±10 ±18 ±10
±6 ±8 ±10 ±4 ±10 ±4 ±4 ±10 ±18 ±6
±4 ±8 ±10 ±10 ±4 ±10 ±18
±7 ±7 ±7 ±7 ±16
±6 ±7 ±7 ±7 ±16
±7 ±7 ±7 ±16
±12
±12

Sensing face

■ www.balluff.com 71
BIS M Industrial RFID System
Read/write heads

The right choice when you need a flat design


with long read/write distance.

Dimensions
Housing material
For standard processors Ordering code
(up to 2 kByte) Part number
For BIS M-407 processors Ordering code
(up to 2 kByte) Part number
For BIS V processors Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection to
Connection cable

Appropriate data carrier


Installation note for data carriers Data carrier to metal distance in mm
Data carrier clear zone in mm
Clear zone

Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
5 mm
9 mm
Distance to metal 12 mm
15 mm
16 mm
18 mm
20 mm
22 mm
25 mm
30 mm
32 mm
35 mm
40 mm
43 mm
45 mm
50 mm
52 mm
60 mm
65 mm
70 mm
Sensing
face
Mounting: Antenna type:

flush in steel rod

non-flush on steel
round
non-metal

72
BIS M Industrial RFID System
Read/write heads

13.56 MHz HF
80×84.5×40 mm
Range of
PBT, ASA applications
BIS0055 Data carriers
read/write
BIS M-301-001-S115
Read/write
BIS0056 heads
BIS M-301-003-S115 Read/write
BIS00T0 compact
processors
BIS VM-301-001-S4 HF antenna
HF antenna
0...+70 °C compact
processor
–20...+85 °C
HF long range
IP 67 processors
Processor HF long range
See page 274/380 for cable options conveyor
antenna
HF long range
BIS M-115-03/A-SA2

antenna
BIS M-107-03/L-H200

Processors
BIS M-108-20/A
BIS M-101-01/L

BIS M-102-01/L

BIS M-108-02/L

BIS M-110-02/L

BIS M-111-02/L

BIS M-112-02/L

BIS M-120-01/L Gateways


Standard
handheld
BIS00RZ

BIS00LC

BIS003Y

BIS003Z

BIS0043

BIS0111

BIS0044

BIS0045

BIS0046

BIS0047

Access
protection

>0 > 20 > 50 > 5 > 50 > 10 > 50 > 20 > 50 > 20 > 50 > 30 > 50 > 30 > 50 > 30 > 80
> 50 > 110 > 200 > 50 > 200 > 150 > 200 > 60 > 200 > 60 > 200 > 100 > 200 > 100 > 200 > 100 > 250

0...30 0...28 0...34 0...15 0...45 0...35 0...45 8...22 0...45 8...22 0...32 0...20 0...45 0...30 0...70 0...45 0...50
0...30 0...28 0...34 0...15 0...45 0...35 0...45 8...22 0...45 8...22 0...32 0...20 0...45 0...30 0...70 0...45 0...50
±25 ±20 ±22 ±14 ±30 ±18 ±32 ±20 ±32 ±20 ±28 ±20 ±32 ±22 ±40 ±25 ±30
±25 ±20 ±22 ±14 ±30 ±18 ±32 ±20 ±32 ±20 ±28 ±20 ±32 ±22 ±40 ±25 ±30
±20 ±20 ±22 ±14 ±30 ±18 ±32 ±20 ±32 ±20 ±28 ±18 ±32 ±22 ±40 ±25 ±30
±20 ±20 ±22 ±10 ±30 ±18 ±32 ±18 ±32 ±18 ±24 ±18 ±32 ±22 ±40 ±25 ±30
±20 ±20 ±22 ±10 ±30 ±18 ±32 ±18 ±32 ±18 ±24 ±15 ±32 ±20 ±40 ±25 ±30
±20 ±20 ±22 ±8 ±30 ±18 ±32 ±18 ±32 ±18 ±24 ±15 ±32 ±20 ±40 ±25 ±30
±20 ±17 ±22 ±6 ±30 ±18 ±32 ±16 ±32 ±16 ±24 ±12 ±32 ±18 ±40 ±25 ±30
±18 ±17 ±22 ±4 ±30 ±18 ±32 ±16 ±32 ±16 ±24 ±8 ±32 ±16 ±40 ±25 ±30
±18 ±10 ±20 ±30 ±15 ±25 ±14 ±25 ±14 ±20 ±25 ±14 ±40 ±22 ±30
±18 ±5 ±15 ±30 ±15 ±25 ±25 ±20 ±25 ±12 ±40 ±22 ±30
±8 ±15 ±30 ±12 ±25 ±25 ±12 ±25 ±10 ±40 ±22 ±28
±8 ±30 ±8 ±20 ±20 ±12 ±20 ±40 ±22 ±24
±4 ±30 ±4 ±20 ±20 ±20 ±40 ±20 ±22
±24 ±20 ±20 ±20 ±40 ±20 ±18
±20 ±12 ±12 ±12 ±35 ±15 ±14
±16 ±12 ±12 ±12 ±35 ±12 ±12
±4 ±35 ±4
±35
±30
±30
±20

For installation pay attention to Basic Information chapter.

* For use only with processor BIS M-407-039-06-S115!

■ www.balluff.com 73
BIS M Industrial RFID System
Read/write heads
FERROIDENT

FERROIDENT read/write head with rod type antenna. The right


choice when you need a flat design with long read/write distance.
Simply use the arrows for alignment. For fast positioning.

Dimensions
Housing material
For standard processors Ordering code
(up to 2 kByte) Part number
For BIS M-407 processors Ordering code
(up to 2 kByte) Part number
For BIS V processors Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection to
Connection cable

Appropriate data carrier


Installation notes for data carriers
Data carrier clear zone in mm (a)
Data carrier clear zone in mm (b)
Data carrier clear zone in mm (c)
X
a

Y
Metallic mounting surface 40×22 mm
Metallic mounting surface ≥ 200×200 mm
Write distance in mm
b Read distance in mm
Offset in mm at distance
0 mm
5 mm
10 mm
X
a

Y
12 mm
15 mm
18 mm
c b 20 mm
22 mm
25 mm
30 mm
32 mm
35 mm
40 mm
45 mm
50 mm
52 mm
60 mm
65 mm
70 mm
80 mm
90 mm
Sensing 100 mm
face

Mounting: Antenna type:

flush in steel rod

non-flush on steel
round
74 non-metal
BIS M Industrial RFID System
Read/write heads

Mount on steel
FERROIDENT
13.56 MHz HF
80×84.5×40 mm
Range of
PBT, ASA applications
BIS005C Data carriers
read/write
BIS M-351-001-S115*
Read/write
BIS00KU heads
BIS M-351-003-S115* Read/write
BIS00T2 compact
processors
BIS VM-351-001-S4* HF antenna
HF antenna
0...+70 °C compact
processor
–20...+85 °C
HF long range
IP 67 processors
Processor HF long range
See page 274/380 for cable options conveyor
antenna
HF long range
antenna
BIS M-150-02/A

BIS M-151-02/A

BIS M-152-03/A

BIS M-153-02/A

BIS M-154-03/A

BIS M-155-20/A

BIS M-156-20/A
Processors
Gateways
BIS00M2
BIS004H

BIS00P3

BIS00P1
BIS004F

BIS0117

BIS0112
Standard
handheld
Access
protection
> 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 10 > 10 > 240 > 240 > 240 > 240 > 200 > 200 > 10 > 10 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200
> 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 50 > 50 > 480 > 480 > 480 > 480 > 200 > 200 > 50 > 50 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200
> 50 > 50 > 2 > 2 > 50 > 50 0 0 > 50 > 50 > 2 > 2

0...52 0...52 0...52 0...52 0...52 0...52 0...52 0...52


0...65 0...65 0...65 0...65 0...65 0...65 0...65 0...65
0...52 0...52 0...65 0...65 0...52 0...52 0...65 0...65 0...30 0...30 15...30 15...30 0...100 0...100 0...90 0...90 0...30 0...30 15...30 15...30 0...52 0...52 0...65 0...65 0...52 0...52 0...65 0...65
0...52 0...52 0...65 0...65 0...52 0...52 0...65 0...65 0...30 0...30 15...30 15...30 0...100 0...100 0...90 0...90 0...30 0...30 15...30 15...30 0...52 0...52 0...65 0...65 0...52 0...52 0...65 0...65
X Y X Y Y X Y X X Y X Y X Y X Y X Y X Y X Y X Y Y X Y X
±60 ±25 ±65 ±26 ±60 ±25 ±65 ±26 ±35 ±20 ±100 ±20 ±100 ±20 ±35 ±20 ±60 ±25 ±65 ±26 ±60 ±25 ±65 ±26
±60 ±25 ±65 ±26 ±60 ±25 ±65 ±26 ±35 ±20 ±100 ±20 ±100 ±20 ±35 ±20 ±60 ±25 ±65 ±26 ±60 ±25 ±65 ±26
±60 ±25 ±65 ±26 ±60 ±25 ±65 ±26 ±35 ±20 ±100 ±20 ±100 ±20 ±35 ±20 ±60 ±25 ±65 ±26 ±60 ±25 ±65 ±26
±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25 ±35 ±20 ±100 ±20 ±100 ±20 ±35 ±20 ±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25
±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25 ±35 ±20 ±35 ±15 ±100 ±20 ±100 ±20 ±35 ±20 ±35 ±15 ±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25
±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25 ±35 ±20 ±35 ±15 ±100 ±20 ±100 ±20 ±35 ±20 ±35 ±15 ±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25
±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25 ±35 ±20 ±35 ±15 ±100 ±20 ±100 ±20 ±35 ±20 ±35 ±15 ±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25
±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25 ±20 ±20 ±28 ±15 ±100 ±20 ±100 ±20 ±20 ±20 ±28 ±15 ±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25
±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25 ±20 ±12 ±28 ±15 ±80 ±20 ±80 ±20 ±20 ±12 ±28 ±15 ±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25
±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25 ±20 ±12 ±28 ±15 ±80 ±20 ±80 ±20 ±20 ±12 ±28 ±15 ±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25
±50 ±25 ±65 ±25 ±50 ±25 ±65 ±25 ±80 ±20 ±80 ±20 ±50 ±25 ±65 ±25 ±50 ±25 ±65 ±25
±50 ±25 ±65 ±25 ±50 ±25 ±65 ±25 ±80 ±20 ±80 ±20 ±50 ±25 ±65 ±25 ±50 ±25 ±65 ±25
±50 ±20 ±50 ±25 ±50 ±20 ±50 ±25 ±80 ±20 ±80 ±20 ±50 ±20 ±50 ±25 ±50 ±20 ±50 ±25
±25 ±20 ±50 ±25 ±25 ±20 ±50 ±25 ±80 ±20 ±80 ±20 ±25 ±20 ±50 ±25 ±25 ±20 ±50 ±25
±25 ±20 ±50 ±25 ±25 ±20 ±50 ±25 ±80 ±20 ±80 ±20 ±25 ±20 ±50 ±25 ±25 ±20 ±50 ±25
±25 ±8 ±25 ±25 ±25 ±8 ±25 ±25 ±80 ±20 ±80 ±20 ±25 ±8 ±25 ±25 ±25 ±8 ±25 ±25
±25 ±10 ±25 ±10 ±65 ±20 ±65 ±20 ±25 ±10 ±25 ±10
±25 ±10 ±25 ±10 ±65 ±20 ±65 ±20 ±25 ±10 ±25 ±10
±65 ±20 ±65 ±20
±65 ±20 ±65 ±20
±50 ±20 ±50 ±20
±40 ±20

For installation pay attention to Basic Information chapter.

Supported standard
* ISO 15693

■ www.balluff.com 75
BIS M Industrial RFID System
Read/write heads

Dimensions
Housing material
For standard processors Ordering code
(up to 2 kByte) Part number
For BIS M-407 processors Ordering code
(up to 2 kByte) Part number
For BIS V processors Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection to
Connection cable

Appropriate data carrier


Installation note for data carriers Data carrier to metal distance in mm
Data carrier clear zone in mm
Clear zone

Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
5 mm
9 mm
Distance to metal 12 mm
15 mm
16 mm
18 mm
20 mm
22 mm
25 mm
30 mm
35 mm
40 mm
45 mm
50 mm
60 mm
70 mm
80 mm
90 mm

Mounting: Antenna type:


Sensing
face flush in steel rod

non-flush on steel
round
non-metal

76
BIS M Industrial RFID System
Read/write heads

13.56 MHz HF
80×84.5×40 mm
BIS M
PBT, ASA Industrial
BIS00M6 RFID System
BIS M-341-001-S115* Range of
applications
BIS00R3 Read/write
BIS M-341-003-S115* distances
overview
BIS00TA
Data carriers
BIS VM-341-001-S4*
Read/write
heads
0...+70 °C Read/write
compact
–20...+85 °C processors
IP 67 HF antenna
Proccessor Processors
See page 274/380 for cable options Gateways
Standard
handheld
BIS M-140-02/A-M_

BIS M-142-02/A-M_

BIS M-142-20/A-M_

BIS M-143-02/A-M_

BIS M-144-02/A-M_

Access
see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

protection
BIS M-108-20/A
BIS M-112-02/L

BIS M-108-02/L
BIS0046

BIS0043

BIS0111

>0 > 50 > 50 > 0 > 50 > 0 >0 >0 >0 >0
> 100 > 200 > 200 > 0 > 200 > 0 > 100 > 100 > 100 > 100

35...90 20...60 0...50 20...60 0...50


35...90 20...60 0...50 20...60 0...50
±25 ±30 ±30 ±25 ±25 ±25
±25 ±30 ±30 ±25 ±25 ±25 ±25
±25 ±30 ±30 ±25 ±25 ±17 ±25
±25 ±30 ±30 ±25 ±25 ±17 ±25
±25 ±30 ±30 ±25 ±25 ±17 ±25
±25 ±30 ±30 ±25 ±25 ±17 ±25
±25 ±30 ±30 ±25 ±25 ±17 ±25
±25 ±35 ±30 ±35 ±30 ±25 ±25 ±25
±25 ±35 ±30 ±35 ±30 ±25 ±25 ±25
±25 ±35 ±30 ±35 ±30 ±25 ±25 ±25
±15 ±35 ±30 ±35 ±30 ±25 ±25 ±25
±15 ±55 ±30 ±20 ±30 ±20 ±15 ±15 ±15
±10 ±55 ±30 ±20 ±30 ±20 ±15 ±15 ±15
±55 ±30 ±20 ±30 ±20
±55 ±30 ±20 ±30 ±20
±55 ±30 ±30
±40
±40
±20

For installation pay attention to Basic Information chapter.

Supported standard
* ISO 15693

■ www.balluff.com 77
BIS M Industrial RFID System
Read/write compact processors
Serial
and IO-Link
When the available space requires a flat housing, this version
is the ideal choice. For direct connection to the controller.

Dimensions
Housing material
Serial, RS232 Ordering code
(up to 2 kByte) Part number
IO-Link, 10 byte Ordering code
Part number
IO-Link, 32 byte Ordering code
Part number
Mounting
Supply voltage
Current
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection type
Accessories included
Connection cable

Appropriate data carrier


Installation note for data carriers Data carrier to metal distance in mm
Data carrier clear zone in mm
Clear zone

Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
5 mm
9 mm
Distance to metal 12 mm
15 mm
16 mm
18 mm
20 mm
22 mm
25 mm
30 mm
32 mm
35 mm
40 mm
43 mm
45 mm
50 mm
52 mm
60 mm

Sensing Mounting: Antenna type:


face
flush in steel rod

non-flush on steel
round
non-metal

78
BIS M Industrial RFID System
Read/write compact processors

13.56 MHz HF
80×80×40
0×40 mm
BIS M
PBT, ASA Industrial
BIS00EM RFID System
BIS M-401-007-001-00-S115 Range of
applications
BIS00LK Read/write
BIS M-401-045-001-07-S4 distances
overview
BIS0102
Data carriers
BIS M-401-072-001-07-S4
Read/write
heads
24 V DC +10 %/–20 % including ripple Read/write
compact
≤ 50 mA no-load processors
0...+70 °C HF antenna
–20...+85 °C Processors
IP 67 Gateways
1× M12 connector male, 8-pin (serial) or 4-pin (IO-Link) Standard
handheld
Serial includes configuration software
Access
See page 274/380 for cable options protection
BIS M-140-02/A-M6

BIS M-140-02/A-M8
BIS M-108-20/A
BIS M-101-01/L

BIS M-102-01/L

BIS M-120-01/L

BIS M-108-02/L

BIS M-110-02/L

BIS M-111-02/L

BIS M-112-02/L

BIS00M9

BIS00M8
BIS003Y

BIS003Z

BIS0047

BIS0043

BIS0111

BIS0044

BIS0045

BIS0046

> 50 > 10 > 50 > 10 > 80 > 50 > 20 > 50 > 20 > 50 > 30 > 50 > 30 > 50 > 30 >0 >0
> 200 > 150 > 200 > 150 >250 > 200 > 60 > 200 > 60 > 200 > 100 > 200 > 100 > 200 > 100 > 100 > 100

0...28 0...20 0...45 0...34 0...50 0...40 0...18 0...40 0...18 0...30 0...18 0...40 0...25 0...60 0...25 0...32 0...32
0...28 0...20 0...45 0...34 0...50 0...40 0...18 0...40 0...18 0...30 0...18 0...40 0...25 0...60 0...25 0...32 0...32
±22 ±12 ±30 ±16 ±30 ±30 ±16 ±30 ±16 ±25 ±18 ±30 ±20 ±35 ±25 ±25 ±25
±22 ±12 ±30 ±16 ±30 ±30 ±16 ±30 ±16 ±25 ±18 ±30 ±20 ±35 ±25 ±25 ±25
±22 ±10 ±30 ±16 ±30 ±30 ±16 ±30 ±16 ±25 ±15 ±30 ±20 ±35 ±25 ±25 ±25
±22 ±8 ±30 ±14 ±30 ±25 ±16 ±25 ±16 ±20 ±15 ±25 ±20 ±35 ±25 ±25 ±25
±22 ±8 ±30 ±14 ±30 ±25 ±16 ±25 ±16 ±20 ±12 ±25 ±18 ±35 ±25 ±25 ±25
±20 ±6 ±30 ±12 ±30 ±25 ±16 ±25 ±16 ±20 ±12 ±25 ±18 ±35 ±25 ±25 ±25
±20 ±4 ±30 ±10 ±30 ±25 ±14 ±25 ±14 ±20 ±8 ±25 ±16 ±35 ±25 ±25 ±25
±20 ±2 ±30 ±10 ±30 ±25 ±25 ±20 ±25 ±14 ±35 ±25 ±25 ±25
±16 ±24 ±8 ±30 ±20 ±20 ±15 ±20 ±12 ±35 ±22 ±20 ±20
±12 ±24 ±8 ±30 ±20 ±20 ±15 ±20 ±10 ±35 ±22 ±20 ±20
±24 ±6 ±28 ±20 ±20 ±10 ±20 ±35 ±22 ±15 ±15
±20 ±4 ±24 ±15 ±15 ±10 ±15 ±35 ±22 ±15 ±15
±20 ±22 ±15 ±15 ±15 ±35 ±20
±15 ±18 ±15 ±15 ±15 ±35
±8 ±14 ±25
±5 ±12 ±25
±4 ±25
±25
±25

For installation pay attention to Basic Information chapter.

■ www.balluff.com 79
BIS M Industrial RFID System
Read/write compact processors
FERROIDENT
Serial and IO-Link
FERROIDENT read/write head with rod type antenna. The right
choice when you need a flat design with long read/write distance.
Simply use the arrows for alignment. For fast positioning.

Dimensions
Housing material
Serial, RS232 Ordering code
(up to 2 kByte) Part number
IO-Link, 10 byte Ordering code
Part number
IO-Link, 32 byte Ordering code
Part number
Mounting
Supply voltage
Current
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection type
Accessories included
Connection cable

Appropriate data carrier


Installation notes for data carriers Data carrier clear zone in mm (a)
Data carrier clear zone in mm (b)
Data carrier clear zone in mm (c)
X
a

Y
Metallic mounting surface 40×22 mm
Metallic mounting surface ≥ 200×200 mm
Write distance in mm
b Read distance in mm
Offset in mm at distance
0 mm
5 mm
10 mm
X
a

Y
12 mm
15 mm
18 mm
c b 20 mm
22 mm
25 mm
30 mm
32 mm
Mounting: 35 mm
40 mm
flush in steel
45 mm
non-flush on steel 50 mm
52 mm
non-metal
60 mm
65 mm
Antenna type: 70 mm
rod 80 mm
90 mm
Sensing 100 mm
round face

For installation pay attention to Basic Information chapter.


80
BIS M Industrial RFID System
Read/write compact processors

Mount on steel
FERROIDENT
13.56 MHz HF
80×84.5×40 mm
BIS M
PBT, ASA Industrial
BIS00ER RFID System
BIS M-451-007-001-00-S115 Range of
applications
BIS00LM Read/write
BIS M-451-045-001-07-S4 distances
overview
BIS0103
Data carriers
BIS M-451-072-001-07-S4
Read/write
heads
24 V DC +10 %/–20 % including ripple Read/write
compact
≤ 50 mA no-load processors
0...+70 °C HF antenna
–20...+85 °C Processors
IP 67 Gateways
1× M12 connector male, 8-pin (serial) or 4-pin (IO-Link) Standard
handheld
Serial includes configuration software
Access
See page 274/380 for cable options protection
BIS M-150-02/A

BIS M-151-02/A

BIS M-152-03/A

BIS M-153-02/A

BIS M-154-03/A

BIS M-155-20/A

BIS M-156-20/A
BIS00M2
BIS004H

BIS00P3

BIS00P1
BIS004F

BIS0117

BIS0112
> 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 10 > 10 > 240 > 240 > 200 > 200 > 10 > 10 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200
> 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 50 > 50 > 480 > 480 > 200 > 200 > 50 > 50 > 200 > 200 > 200 > 200 > 200 > 200 > 200 > 200
> 50 > 50 > 2 > 2 > 50 > 50 > 50 > 50 > 2 > 2

0...52 0...52 0...52 0...52 0...52 0...52 0...52 0...52


0...65 0...65 0...65 0...65 0...65 0...65 0...65 0...65
0...52 0...52 0...65 0...65 0...52 0...52 0...65 0...65 0...30 0...30 15...30 15...30 0...100 0...100 0...30 0...30 15...30 15...30 0...52 0...52 0...65 0...65 0...52 0...52 0...65 0...65
0...52 0...52 0...65 0...65 0...52 0...52 0...65 0...65 0...30 0...30 15...30 15...30 0...100 0...100 0...30 0...30 15...30 15...30 0...52 0...52 0...65 0...65 0...52 0...52 0...65 0...65
X Y X Y Y X Y X X Y X Y X Y X Y X Y X Y X Y Y X Y X
±60 ±25 ±65 ±26 ±60 ±25 ±65 ±26 ±35 ±20 ±60 ±20 ±35 ±20 ±60 ±25 ±65 ±26 ±60 ±25 ±65 ±26
±60 ±25 ±65 ±26 ±60 ±25 ±65 ±25 ±35 ±20 ±60 ±20 ±35 ±20 ±60 ±25 ±65 ±26 ±60 ±25 ±65 ±25
±60 ±25 ±65 ±26 ±60 ±25 ±65 ±25 ±35 ±20 ±60 ±20 ±35 ±20 ±60 ±25 ±65 ±26 ±60 ±25 ±65 ±25
±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25 ±35 ±20 ±60 ±20 ±35 ±20 ±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25
±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25 ±35 ±20 ±35 ±15 ±60 ±20 ±35 ±20 ±35 ±15 ±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25
±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25 ±35 ±20 ±35 ±15 ±60 ±20 ±35 ±20 ±35 ±15 ±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25
±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25 ±35 ±20 ±35 ±15 ±60 ±20 ±35 ±20 ±35 ±15 ±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25
±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25 ±35 ±20 ±35 ±15 ±60 ±20 ±35 ±20 ±35 ±15 ±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25
±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25 ±20 ±12 ±28 ±15 ±60 ±20 ±20 ±12 ±28 ±15 ±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25
±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25 ±20 ±12 ±28 ±15 ±60 ±20 ±20 ±12 ±28 ±15 ±60 ±25 ±65 ±25 ±60 ±25 ±65 ±25
±50 ±25 ±65 ±25 ±50 ±25 ±65 ±25 ±60 ±20 ±50 ±25 ±65 ±25 ±50 ±25 ±65 ±25
±50 ±25 ±65 ±25 ±50 ±25 ±65 ±25 ±60 ±20 ±50 ±25 ±65 ±25 ±50 ±25 ±65 ±25
±50 ±20 ±50 ±25 ±50 ±20 ±50 ±25 ±60 ±20 ±50 ±20 ±50 ±25 ±50 ±20 ±50 ±25
±25 ±20 ±50 ±25 ±25 ±20 ±50 ±25 ±60 ±20 ±25 ±20 ±50 ±25 ±25 ±20 ±50 ±25
±25 ±20 ±50 ±25 ±25 ±20 ±50 ±25 ±60 ±20 ±25 ±20 ±50 ±25 ±25 ±20 ±50 ±25
±25 ±8 ±25 ±25 ±25 ±8 ±25 ±25 ±60 ±20 ±25 ±8 ±25 ±25 ±25 ±8 ±25 ±25
±25 ±10 ±25 ±10 ±60 ±20 ±25 ±10 ±25 ±10
±25 ±10 ±25 ±10 ±60 ±20 ±25 ±10 ±25 ±10
±60 ±20
±60 ±20
±40 ±20
±40 ±20

■ www.balluff.com 81
BIS M Industrial RFID System
Read/write compact processors

Dimensions
Housing material
Subnet16*, RS485 Ordering code
Part number
Serial, RS232 Ordering code
Part number
Serial, RS422 Ordering code
Part number
Serial, USB Ordering code
Part number
Mounting
Supply voltage
Current
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection type

Appropriate data carrier (common for all heads)


Installation notes for data carriers Data carrier to metal distance in mm
Clear zone Data carrier clear zone in mm

Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
5 mm
10 mm
15 mm
23 mm
Distance to metal 32 mm
46 mm
60 mm
70 mm
85 mm

For installation pay attention to Basic Information chapter.

* See Gateways on page 122 for multiprocessor configuration.

Mounting:

flush in steel
Clear zone non-flush on steel

non-metal

Antenna type:
Clear zone
rod

round

82
BIS M Industrial RFID System
Read/write compact processors

13.56 MHz HF
56×40×42 mm 56×40×42 mm 56×40×42 mm 56×40×42 mm
BIS M
PC PC PC PC Industrial
BIS00W1 RFID System
BIS M-410-067-001-04-S92 Range of
applications
BIS00W2 Read/write
BIS M-410-068-001-00-S115 distances
overview
BIS00W3
Data carriers
BIS M-410-068-001-02-S115
Read/write
BIS00W4 heads
BIS M-410-068-001-09-S72 Read/write
compact
processors
10...30 V DC over bus 10...30 V DC over bus 10...30 V DC over bus 5 V DC HF antenna
87 mA at 24 V DC 87 mA at 24 V DC 87 mA at 24 V DC Processors
–20...+50 °C –20...+50 °C –20...+50 °C –20...+50 °C Gateways
–40...+85 °C –40...+85 °C –40...+85 °C –40...+85 °C Standard
handheld
IP 67 IP 67 IP 67 IP 67
Access
M12 connector male, 5-pin M12 connector male, 8-pin M12 connector male, 8-pin M12 connector male, 5-pin, B-coded protection
BIS M-132-03/L-HT

BIS M-132-10/L-HT

BIS M-134-10/L-HT

BIS M-135-03/L-HT

BIS M-135-07/L-HT
BIS M-133-02/A
BIS M-132-03/L

BIS M-132-10/L

BIS M-135-02/L

BIS M-135-03/L

BIS M-135-07/L

BIS M-136-03/L

BIS M-130-03/L

BIS M-130-07/L
BIS00W9
BIS00YC

BIS00YK
BIS00YE

BIS00YA
BIS00YF

BIS00YL
BIS00Y9

BIS00Y7

BIS00Y6

BIS00Y5

BIS00Y4

BIS00Y3

BIS00Y2

> 50 > 50 > 50 > 50 > 50 > 50 > 50 > 50 > 50 > 50 > 50 > 50 > 50 > 50
> 50 > 50 > 50 > 50 > 50 > 50 > 50 > 50 > 50 > 50 > 50 > 50 > 50 > 50

0...48 0...40 0...15 0...15 0...32 0...36 0...60 0...68 0...20 0...85 0...7 0...10
0...48 0...40 0...15 0...15 0...32 0...36 0...60 0...68 0...20 0...85 0...7 0...10
±30 ±25 ±15 ±15 ±20 ±25 ±35 ±40 ±44 ±40 ±11 ±12
±30 ±25 ±15 ±15 ±20 ±25 ±35 ±40 ±44 ±40 ±8 ±10
±30 ±25 ±12 ±12 ±20 ±25 ±35 ±40 ±44 ±40 ±5
±25 ±20 ±8 ±8 ±16 ±25 ±35 ±40 ±44 ±40
±25 ±20 ±10 ±20 ±35 ±40 ±32 ±25 ±24 ±35
±20 ±12 ±8 ±12 ±30 ±32 ±32 ±20 ±18 ±35
±12 ±24 ±32 ±32 ±10 ±10 ±35
±16 ±24 ±25 ±25
±15 ±25
±20

39.2
15.5
12.5

24
40 14.3
67

2× mounting
28 hole Ø 4.5 mm

■ www.balluff.com 83
BIS M Industrial RFID System
Read/write compact processors

Dimensions
Housing material
Subnet16*, RS485 Ordering code
Part number
Serial, RS232 Ordering code
Part number
Serial, RS422 Ordering code
Part number
Serial, USB Ordering code
Part number
Mounting
Supply voltage
Current
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection type

The Unit may be mounted to wood,


plastic fixtures and metal plate surfaces.
However, do not recess the controller
in metal. For optimal performance, allow
60 mm (2.5 inches) clearance from
metallic objects around the sides of
the controller.
Appropriate data carrier (common for all heads)
Installation notes for data carriers Data carrier to metal distance in mm
Clear zone Data carrier clear zone in mm

Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
11 mm
22 mm
26 mm
38 mm
Distance to metal 52 mm
60 mm
75 mm
95 mm
100 mm
110 mm
125 mm
150 mm
155 mm

For installation pay attention Antenna type:


to Basic Information chapter.
rod
Clear zone
* See Gateways on page 122
for multiprocessor configuration.
round
Mounting:

flush in steel
Clear zone
non-flush on steel

non-metal

84
BIS M Industrial RFID System
Read/write compact processors

13.56 MHz HF
105×73×24 mm 105×73×24 mm 105×73×24 mm 105×73×24 mm
BIS M
PC PC PC PC Industrial
BIS00W5 RFID System
BIS M-411-067-001-04-S92 Range of
applications
BIS00W6 Read/write
BIS M-411-068-001-00-S115 distances
overview
BIS00W7
Data carriers
BIS M-411-068-001-02-S115
Read/write
BIS00W8 heads
BIS M-411-068-001-09-S72 Read/write
compact
processors
10...30 V DC 10...30 V DC 10...30 V DC 5 V DC HF antenna
87 mA at 24 V DC 87 mA at 24 V DC 87 mA at 24 V DC Processors
–20...+50 °C –20...+50 °C –20...+50 °C –20...+50 °C Gateways
–20...+70 °C –20...+70 °C –20...+70 °C –20...+70 °C Standard
handheld
IP 67 IP 67 IP 67 IP 67
Access
M12 connector male, 5-pin M12 connector male, 8-pin M12 connector male, 8-pin M12 connector male, 5-pin, B-coded protection
BIS M-132-03/L-HT

BIS M-132-10/L-HT

BIS M-134-10/L-HT

BIS M-135-03/L-HT

BIS M-135-07/L-HT
BIS M-133-02/A
BIS M-132-03/L

BIS M-132-10/L

BIS M-135-02/L

BIS M-135-03/L

BIS M-135-07/L

BIS M-136-03/L

BIS M-130-07/L
BIS00W9
BIS00YC

BIS00YK
BIS00YE

BIS00YA
BIS00YF

BIS00Y9

BIS00Y7

BIS00Y6

BIS00Y5

BIS00Y4

BIS00Y3

BIS00Y2

> 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10
> 100 > 100 > 100 > 100 > 100 > 100 > 100 > 100 > 100 > 100 > 100 > 100 > 100

0...80 0...70 0...26 0...22 38...52 0...60 0...100 0...110 0...125 11...95 11...75 0...155 0...13
0...80 0...70 0...26 0...22 38...52 0...60 0...100 0...110 0...125 11...95 11...75 0...155 0...13
±50 ±42 ±20 ±20 ±32 ±50 ±62 ±65 ±90 ±4
±50 ±42 ±20 ±20 ±32 ±50 ±62 ±65 ±52 ±50 ±90 ±4
±40 ±39 ±15 ±10 ±32 ±50 ±62 ±65 ±52 ±50 ±90
±40 ±39 ±15 ±30 ±50 ±62 ±65 ±52 ±50 ±90
±40 ±39 ±25 ±30 ±50 ±58 ±65 ±48 ±42 ±80
±35 ±36 ±25 ±25 ±50 ±58 ±62 ±48 ±42 ±80
±35 ±36 ±20 ±50 ±58 ±62 ±48 ±35 ±80
±30 ±45 ±52 ±62 ±44 ±35 ±80
±45 ±52 ±58 ±40 ±75
±45 ±52 ±58 ±75
±50 ±58 ±75
±50 ±60
±60
±50

105.8
8.8
75.2
8.8

116.4
15.9
24

19
12.5
12.5

■ www.balluff.com 85
BIS M Industrial RFID System
Read/write heads

The Balluff BIS-M System


combines advantages such as
the fully flush installation of data
carriers in steel and absolute
data reliability with important
properties such as:
■ Large reading/writing distan-
ces of up to 130 mm
■ Fast data communication
from data carrier via processor
to controller Dimensions 25×50×10
5×50×10 mm
■ Seamless integration in Housing material Aluminum, anodized and ABS (fiberglass reinforced)
intralogistics applications Standard Ordering code BIS00NY
through global standard (up to 2 kByte) Part number BIS M-352-001-S115*
ISO 15693/14443 Mounting
■ Smallest possible Operating temperature 0...+70 °C
antenna design sizes Storage temperature –20...+85 °C
Degree of protection per IEC 60529 IP 67
The components are specially Cable type 0.5 m cable PUR
designed and manufactured for Connection to Processor
use with transfer systems from Connection cable See page 380 for cable options
Bosch-Rexroth (TS1 and TS2).
The design not only takes RFID
communication into considera-

BIS M-191-02/A

BIS M-152-03/A
tion but also simple assembly.

BIS00M2
BIS00NZ

Can be installed from the kit,


depending on the application.
Thanks to the robust systems Appropriate data carrier
and 20 years of experience with Data carrier to metal distance in mm > 27 > 27 >0 >0
RFID, the described solution is a Data carrier clear zone in mm > 27 > 27 >0 >0
must for every automation task.
Write distance in mm 0...22 0...22 0...17 0...17 Installation note
Read distance in mm 0...22 0...22 0...17 0...17 for data carriers
Offset in mm at distance X Y X Y
0 mm ±25 ±5 ±22 ±8 Y
5 mm ±25 ±5 ±22 ±8 X b
Installation note for data carriers
9 mm ±25 ±5 ±22 ±8
10 mm ±25 ±5 ±22 ±8
11 mm ±25 ±5 ±22 ±8
Clear zone

12 mm ±25 ±5 ±22 ±8
a
15 mm ±25 ±5 ±15 ±8
17 mm ±25 ±5 ±15 ±8
a

20 mm ±15 ±5
22 mm ±15 ±5
Distance to metal

For installation pay attention to Basic Information chapter.


Sensing
face
Supported standard
*ISO 15693

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round
BIS M Industrial RFID System
Read/write heads

13.56 MHz HF
25×50×10
5×50×10 mm M18×1
BIS M
Aluminum, anodized and ABS (fiberglass reinforced) Aluminum, anodized and brass, coated Industrial
BIS00NK BIS00P2 RFID System
BIS M-305-001-S115 BIS M-307-001-S115 Range of
applications
Read/write
0...+70 °C 0...+70 °C distances
overview
–20...+85 °C –20...+85 °C
Data carriers
IP 67 IP 67
Read/write
0.5 m cable PUR 0.5 m cable PUR heads
Processor Processor Read/write
compact
See page 380 for cable options See page 380 for cable options processors
HF antenna
BIS M-144-02/A-M6-GY

Processors
BIS M-140-02/A-M6

Gateways
BIS M-105-01/A

BIS M-105-02/A

BIS M-122-01/A

BIS M-122-02/A

BIS M-105-01/A

BIS M-105-02/A

BIS M-122-01/A

BIS M-122-02/A
BIS M-110-02/L

BIS M-108-02/L

BIS M-110-02/L
Standard
handheld
Access
BIS00M9

BIS00R4
BIS004A

BIS004A
protection
BIS0040

BIS0042

BIS0044

BIS0048

BIS0043

BIS0040

BIS0042

BIS0044

BIS0048
> 10 >0 > 10 >0 > 25 >0 > 10 >0 > 10 > 0 > 25 > 0 >0 >0 > 10 >0 > 10 >0 > 25 >0 > 10 >0 > 10 >0
> 60 >0 > 60 >0 > 80 >0 > 60 >0 > 60 > 0 > 100 > 0 > 100 > 100 > 60 >0 > 60 >0 > 80 >0 > 60 >0 > 60 >0

0...6 0...4 0...8 0...6 0...13 0...5 0...4 0...7 0...5 0...17 0...11 0...15 0...13 0...6 0...4 0...8 0...6 0...13 0...5 0...4 0...7 0...5
0...6 0...4 0...8 0...6 0...13 0...5 0...4 0...7 0...5 0...17 0...11 0...15 0...13 0...6 0...4 0...8 0...6 0...13 0...5 0...4 0...7 0...5

±3 ±3 ±4 ±4 ±6 ±3 ±3 ±4 ±3 ±12 ±8 ±8 ±8 ±3 ±3 ±4 ±4 ±6 ±3 ±3 ±4 ±3
±2 ±4 ±2 ±6 ±2 ±3 ±2 ±12 ±8 ±8 ±8 ±2 ±4 ±2 ±6 ±2 ±3 ±2
±4 ±12 ±6 ±8 ±8 ±4
±4 ±12 ±6 ±8 ±8 ±4
±4 ±10 ±4 ±6 ±6 ±4
±2 ±10 ±6 ±2
±8 ±6
±4

Sensing
Sensing face
face

■ www.balluff.com 87
BIS M Industrial RFID System
Read/write heads
New Generation

Dimensions
Housing material
For BIS V processor Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Cable type
Connection to
Connection cable

Appropriate data carrier


Installation note for data carriers Data carrier to metal distance in mm
Data carrier clear zone in mm
Clear zone

Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
5 mm
9 mm
Distance to metal 10 mm
11 mm
12 mm
15 mm

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

88
BIS M Industrial RFID System
Read/write heads

13.56 MHz HF
M12×1 M18×1
BIS M
Aluminum, anodized and brass, coated Aluminum, anodized and brass, coated Industrial
BIS00T7 BIS00T8 RFID System
BIS VM-306-001-S4 BIS VM-307-001-S4 Range of
applications
Read/write
0...+70 °C 0...+70 °C distances
overview
–20...+85 °C –20...+85 °C
Data carriers
IP 67 IP 67
Read/write
0.5 m cable PUR 0.5 m cable PUR heads
Processor Processor Read/write
compact
See page 274 for cable options See page 274 for cable options processors
HF antenna
Processors

BIS M-140-02/A-M_

BIS M-142-02/A-M_

BIS M-143-02/A-M_

BIS M-144-02/A-M_
Gateways

see data carriers

see data carriers

see data carriers

see data carriers


BIS M-105-01/A

BIS M-105-02/A

BIS M-116-03/A

BIS M-122-02/A

BIS M-105-01/A

BIS M-105-02/A

BIS M-122-01/A

BIS M-122-02/A
BIS M-110-02/L

Standard
handheld
Access
BIS00UC

BIS004A

BIS004A
protection
BIS0040

BIS0042

BIS0040

BIS0042

BIS0044

BIS0048

>5 >5 >0 >5 >5 > 10 > 0 > 10 > 0 > 25 > 0 > 10 > 0 > 10 > 0 >0 >0 >0 >0
> 10 > 10 > 10 > 10 > 10 > 60 > 0 > 60 > 0 > 80 > 0 > 60 > 0 > 60 > 0 > 100 > 100 > 100 > 100

0...5 0...6 0...1 0...3 0...5 0...6 0...4 0...8 0...6 0...13 0...5 0...4 0...7 0...5 0...15 0...13 0...10 0...13
0...5 0...6 0...1 0...3 0...5 0...6 0...4 0...8 0...6 0...13 0...5 0...4 0...7 0...5 0...15 0...13 0...10 0...13
±2 ±2 ±1 ±2 ±2 ±3 ±3 ±4 ±4 ±6 ±3 ±3 ±4 ±3 ±10 ±8 ±5 ±8
±1 ±2 ±1 ±2 ±4 ±2 ±6 ±2 ±3 ±2 ±10 ±8 ±5 ±8
±4 ±10 ±8 ±5 ±8
±4 ±10 ±8 ±5 ±8
±2 ±8 ±8 ±6
±2 ±8 ±6
±8

12 12
12 18
9.64 14.5
13
13

37.25
32.9

46.5
29.5
80
80
14.7

14.7
34.8

34.8

20.8 20.8

■ www.balluff.com 89
BIS M Industrial RFID System
Read/write heads
New Generation

Dimensions
Housing material
For BIS V processor Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Cable type
Connection to
Connection cable

Installation note Appropriate data carrier


for data carriers
Data carrier to metal distance in mm
Data carrier clear zone in mm
Y
b

X
Write distance in mm
Read distance in mm
Offset in mm at distance
0 mm
5 mm
a 9 mm
10 mm
11 mm
a

12 mm
15 mm
17 mm

For installation pay attention to Basic Information chapter.

Supported standard
*ISO 15693
Recommended accessories
(please order separately) Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

Description Mounting bracket


Ordering code BAM01MY
Part number BAM MB-XA-010-B07-4
See accessories section. Please order separately.

90
BIS M Industrial RFID System
Read/write heads

13.56 MHz HF
25×50×10 mm 25×50×10 mm
BIS M
Aluminum, anodized and ABS (fiberglass reinforced) Aluminum, anodized and ABS (fiberglass reinforced) Industrial
BIS0076 BIS00T9 RFID System
BIS VM-352-001-S4* BIS VM-305-001-S4 Range of
applications
Read/write
0...+70 °C 0...+70 °C distances
overview
–20...+85 °C –20...+85 °C
Data carriers
IP 67 IP 67
Read/write
0.5 m cable PUR 0.5 m cable PUR heads
Processor Processor Read/write
compact
See page 274 for cable options See page 274 for cable options processors
HF antenna

BIS M-144-02/A-M6-GY
Processors

BIS M-140-02/A-M6
Gateways
BIS M-191-02/A

BIS M-105-01/A

BIS M-105-02/A

BIS M-122-01/A

BIS M-122-02/A

BIS M-108-20/A
BIS M-110-02/L

BIS M-108-02/L
Standard
handheld
Access

BIS00M9
BIS00NZ

BIS00R4
BIS004A
BIS0040

BIS0042

BIS0044

BIS0048

BIS0043

BIS0111
protection

> 27 > 27 > 10 > 0 > 10 > 0 > 25 > 0 > 10 > 0 > 10 > 0 > 25 > 0 > 25 > 0 >0 >0
> 27 > 27 > 60 > 0 > 60 > 0 > 80 > 0 > 60 > 0 > 60 > 0 > 100 > 0 > 100 > 0 > 100 > 100

0...22 0...22 0...6 0...4 0...8 0...6 0...13 0...5 0...4 0...7 0...5 0...17 0...11 0...17 0...11 0...15 0...13
0...22 0...22 0...6 0...4 0...8 0...6 0...13 0...5 0...4 0...7 0...5 0...17 0...11 0...17 0...11 0...15 0...13
X Y
±25 ±5 ±3 ±3 ±4 ±4 ±6 ±3 ±3 ±4 ±3 ±12 ±8 ±12 ±8 ±8 ±8
±25 ±5 ±2 ±4 ±2 ±6 ±2 ±3 ±2 ±12 ±8 ±12 ±8 ±8 ±8
±25 ±5 ±4 ±12 ±6 ±12 ±6 ±8 ±8
±25 ±5 ±4 ±10 ±6 ±10 ±6 ±6 ±6
±25 ±5 ±4 ±10 ±4 ±10 ±4 ±6 ±6
±25 ±5 ±10 ±10 ±6
±25 ±5 ±8 ±8 ±6
±25 ±5 ±4 ±4

12 25 12 25
12.5 12.5
13
13

10
10

50
50

4
4

8
8

80
80

4.2
4.2

7.2 7.2
14.7
14.7

34.8
34.8

20.8 20.8

■ www.balluff.com 91
BIS M Industrial RFID System
Read/write compact processors
Serial
and IO-Link
For tight mounting spaces
The remote electronics of the integrated version creates extra
installation space. For direct connection to the controller

Dimensions M18×1
Housing material Aluminum, anodized and brass, coated
Serial, RS232 Ordering code BIS00EN
Part number BIS M-402-007-002-00-S115
IO-Link, 10 byte Ordering code BIS00LW
Part number BIS M-402-045-002-07-S4
IO-Link, 32 byte Ordering code BIS0105
Part number BIS M-402-072-002-07-S4
Mounting
Supply voltage 24 V DC +10 %
Current ≤ 50 mA no-load / ≤ 150 mA IO-Link
Operating temperature 0...+70 °C
Storage temperature –20...+85 °C
Degree of protection per IEC 60529 IP 67
Connection type 1× M12 connector male, 8-pin (serial) or 4-pin (IO-Link)
Accessories included Configuration software
Connection cable See page 374/388 for cable options

see data carriers

BIS M-116-_ _/A


BIS M-105-01/A

BIS M-105-02/A

BIS M-122-01/A

BIS M-122-02/A

BIS M-110-02/L
BIS004A
BIS0040

BIS0042

BIS0048

BIS0044

Appropriate data carrier


Data carrier to metal distance in mm > 10 >0 > 10 >0 > 10 >0 >10 >0 > 25 >5 >0
Data carrier clear zone in mm > 60 >0 > 60 >0 > 60 >0 > 60 >0 > 80 > 20 > 20

Write distance in mm 0...5 0...3 0...5 0...3 0...5 0...2 0...5 0...2 0...5 0...7 0...4.5
Read distance in mm 0...5 0...3 0...5 0...3 0...5 0...2 0...5 0...2 0...5 0...7 0...4.5
Offset in mm at distance 0 mm ±3 ±2 ±3 ±2 ±3 ±2 ±3 ±2 ±8 ±4 ±3
5 mm ±2 ±2 ±2 ±2 ±8 ±3
9 mm ±6
12 mm ±4
15 mm ±4

Sensing
For installation pay attention to Basic Information chapter. face

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod Installation note for data carriers

round
Clear zone

Distance to metal

92
BIS M Industrial RFID System
Read/write compact processors

13.56 MHz HF
25×50×10 mm 25×50×10 mm
BIS M
Aluminum, anodized and ABS (fiberglass reinforced) Aluminum, anodized and ABS (fiberglass reinforced) Industrial
BIS00RU RFID System
BIS M-402-007-004-00-S115 Range of
applications
BIS00M1 BIS00UY Read/write
BIS M-402-045-004-07-S4 BIS M-402-045-005-07-S4-SA1 distances
overview
BIS0106
Data carriers
BIS M-402-072-004-07-S4
Read/write
heads
24 V DC +10 % 24 V DC +10 % Read/write
compact
≤ 50 mA no-load / ≤ 150 mA IO-Link ≤ 50 mA no-load / ≤ 150 mA IO-Link processors
0...+70 °C 0...+70 °C HF antenna
–20...+85 °C –20...+85 °C Processors
IP 67 IP 67 Gateways
1× M12 connector male, 8-pin (serial) or 4-pin (IO-Link) 1× M12 connector male, 4-pin Standard
handheld
Configuration software Configuration software
Access
See page 374/388 for cable options See page 374/388 for cable options protection
BIS M-105-01/A

BIS M-105-02/A

BIS M-122-01/A

BIS M-122-02/A

BIS M-110-02/L

BIS M-110-02/L
BIS004A
BIS0040

BIS0042

BIS0048

BIS0044

BIS0044

> 10 >0 > 10 >0 > 10 >0 >10 >0 > 25 >5
> 60 >0 > 60 >0 > 60 >0 > 60 >0 > 80 > 50

0...5 0...3 0...5 0...3 0...5 0...2 0...5 0...2 0...15 0...6
0...5 0...3 0...5 0...3 0...5 0...2 0...5 0...2 0...15 0...6
±3 ±2 ±3 ±2 ±3 ±2 ±3 ±2 ±8 ±8
±2 ±2 ±2 ±2 ±8 ±4
±4
±4
±4

Sensing 25
Sensing face
face
8

50
8

20
4.2

15

34.5

Shielding plate BAM01Y8


Read/write device use only with FlexLink
system. Mounting only with included mounting
clamps. Values are under rated conditions
unless otherwise specified.

■ www.balluff.com 93
BIS M Industrial RFID System
HF antenna

One of the challenges of intralogistics is the transportation of cons-


tantly changing materials. However, smooth operation and transpa-
rent processes are still required in spite of the wide variety of different
products. A requirement that is not always easy for RFID systems
because metallic surfaces, fluids and dirt really put these systems to
the test. Not the HF antenna BIS M-350, however. The antenna is
fitted with optimized data carriers that help overcome difficulties of
this kind with ease while reliably ensuring maximum transparency.
All data can be traced at any time.

A Powerful High-frequency package Dimensions


ensures maximum transparency Housing material
■ Distances up to 275 mm offer greater flexibility, Standard Ordering code
regardless of the background surface Part number
■ FRAM data carriers ensure virtually unlimited read/write cycles Mounting
■ Can be used all over the world thanks to ISO-15693-conformity Operating temperature
■ Status indicators mounted directly on the antenna housing Storage temperature
are a valuable feature Degree of protection per IEC 60529
■ The robust housing guarantees reliable operation Connection to
in harsh environments Connection cable
■ 100 % RFID quality means greater reliability
Ordering code
Appropriate data carrier Part number
Data carrier to metal distance in mm
Data carrier clear zone in mm (a × b)

Write distance in mm
Read distance in mm
Offset in mm at distance
0 mm
25 mm
50 mm
75 mm
100 mm
150 mm
200 mm
250 mm

For installation pay attention to Basic Information chapter.

Supported standard
*ISO 15693

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

Installation note for data carriers


X

Y
a

Appropriate data carrier


b BIS M-153 and BIS M-107

94
BIS M Industrial RFID System
HF antenna

FERROIDENT
13.56 MHz HF
240×120×60 mm 240×120×60 mm
BIS M
PC PC Industrial
BIS00LZ BIS00N6 RFID System
BIS M-350-001-S115* BIS M-340-001-S115* Range of
applications
Read/write
0...+55 °C 0...+55 °C distances
overview
–20...+85 °C –20...+85 °C
Data carriers
IP 65 IP 65
Read/write
Processor Processor heads
See page 280 for cable options See page 280 for cable options Read/write
compact
processors
BIS00P3 BIS004H BIS00LC BIS00Y4 HF antenna
BIS M-153-02/A BIS M-151-02/A BIS M-107-03/L-H200 BIS M-135-03/L-HT Processors
0 0 > 120 > 120 Gateways
> 240×480 > 240×480 > 240×480 > 240×480 Standard
handheld
Access
0...275 0...130 0...100 0...200 protection
0...275 0...130 0...100 0...200
X Y X Y X Y X Y
±200 ±100 ±60 ±140 ±50 ±100 ±80 ±100
±200 ±100 ±60 ±135 ±50 ±100 ±80 ±100
±200 ±100 ±60 ±125 ±50 ±95 ±80 ±100
±200 ±100 ±55 ±100 ±45 ±85 ±80 ±100
±200 ±100 ±40 ±75 ±80 ±100
±200 ±100 ±80 ±100
±175 ±100 ±80 ±100
±100 ±100
60

60
17

17

sensing face, sensing face,


direction of direction of
detection detection
226
240
226

Y
240

15 15
20

20

106 106
120 120

■ www.balluff.com 95
BIS M Industrial RFID System
HF antenna compact processor
Ethernet
TCP/IP
One of the challenges of intralogistics is the transportation of cons-
tantly changing materials. However, smooth operation and transpa-
rent processes are still required in spite of the wide variety of different
products. A requirement that is not always easy for RFID systems
because metallic surfaces, fluids and dirt really put these systems to
the test. Not the HF antenna BIS M-350, however. The antenna is
fitted with optimized data carriers that help overcome difficulties of
this kind with ease while reliably ensuring maximum transparency.
All data can be traced at any time.

Dimensions
A Powerful High-frequency package Housing material
ensures maximum transparency Ethernet TCP/IP Ordering code
■ Distances up to 275 mm offer greater flexibility, regardless Part number
of the background surface Mounting
■ FRAM data carriers ensure virtually unlimited read/write cycles Supply voltage
■ Can be used all over the world thanks to ISO-15693-conformity Current
■ Status indicators mounted directly on the antenna housing Operating temperature
are a valuable feature Storage temperature
■ The robust housing guarantees reliable operation Degree of protection per IEC 60529
in harsh environments Connection type
■ 100 % RFID quality means greater reliability
Accessories included
Connection cable

Ordering code
Appropriate data carrier Part number
Data carrier to metal distance
Data carrier clear zone (a × b)

Write distance in mm
Read distance in mm
Offset in mm at distance
0 mm
25 mm
50 mm
75 mm
100 mm
150 mm
200 mm
250 mm

For installation pay attention to Basic Information chapter.

Supported standard
*ISO 15693

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

Installation note for data carriers


X

Y
a

Appropriate data carrier


b BIS M-153 and BIS M-107

96
BIS M Industrial RFID System
HF antenna compact processor

FERROIDENT
13.56 MHz HF
240×120×60 mm 240×120×60 mm
BIS M
PC PC Industrial
BIS00R0 BIS00PZ RFID System
BIS M-450-039-001-06-ST2* BIS M-440-039-001-06-ST2* Range of
applications
Read/write
19.2...28 V DC, ≤ 10 % ripple 19.2...28 V DC, ≤ 10 % ripple distances
overview
≤1A ≤1A
Data carriers
0...+55 °C 0...+55 °C
Read/write
–20...+85 °C –20...+85 °C heads
IP 65 IP 65 Read/write
compact
1× M12 connector male, 5-pin, A-coded (Power) 1× M12 connector male, 5-pin, A-coded (Power) processors
1× M12 connector female, 4-pin, D-coded (Ethernet TCP/IP) 1× M12 connector female, 4-pin, D-coded (Ethernet TCP/IP) HF antenna
Configuration software Configuration software Processors
See page 293/305 for cable options See page 293/305 for cable options Gateways
Standard
handheld
BIS00P3 BIS004H BIS00LC BIS00Y4
Access
BIS M-153-02/A BIS M-151-02/A BIS M-107-03/L-H200 BIS M-135-03/L-HT protection
0 0 > 120 > 120
> 240×480 > 240×480 > 240×480 > 240×480

0...275 0...130 0...100 0...200


0...275 0...130 0...100 0...200
X Y X Y X Y X
±200 ±100 ±60 ±140 ±50 ±100 ±80 ±100
±200 ±100 ±60 ±135 ±50 ±100 ±80 ±100
±200 ±100 ±60 ±125 ±50 ±95 ±80 ±100
±200 ±100 ±55 ±100 ±45 ±85 ±80 ±100
±200 ±100 ±40 ±75 ±80 ±100
±200 ±100 ±80 ±100
±175 ±100 ±80 ±100
±100 ±100
60
60
17

17

sensing face, sensing face,


direction of direction of
detection detection
240
226

226
240
Y
X

15 15
20

20

X2 X1 X1 X2
106 106
120 120

■ www.balluff.com 97
BIS M Industrial RFID System
HF long range processors

These controllers must be used with these antennas:


■ BISM-370
■ BISM-371
■ BISM-372
■ BISM-373

Dimensions
Housing Material
Serial RS232 with IO Ordering code
Part number
Subnet16TM RS485 with IO Ordering code
Part number
Ethernet/IP and Ordering code
Ethernet TCP/IP with IO Part number
Mounting
Supply voltage, Ripple
Current
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Read/write head ports
Service interface
Control inputs
Control outputs
Connection for
Connection type

Accessories included

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

98
BIS M Industrial RFID System
HF long range processors

13.56 MHz HF
114×112×45 mm 114×112×45 mm 114×112×45 mm
BIS M
Aluminum Aluminum Aluminum Industrial
BIS00ZH RFID System
BIS M-620-068-A01-00-ST29* Range of
applications
BIS00ZK Read/write
BIS M-620-067-A01-04-ST30* distances
overview
BIS00ZA
Data carriers
BIS M-626-069-A01-06-ST32*
Read/write
heads
12...30 V DC 12...30 V DC 12...30 V DC Read/write
compact
≤ 400 mA ≤ 400 mA ≤ 400 mA processors
–20...+50 °C –20...+50 °C –20...+50 °C HF antenna
–20...+70 °C –20...+70 °C –20...+70 °C Processors
IP 65 IP 65 IP 65 Gateways
1× external 1× external 1× external Standard
handheld
no no no
Access
1 1 1 protection
2 2 2
Communication/power and I/O Communication/power and I/O Communication/power and I/O
1× M12 connector male, 8-pin 1× M12 connector male, 5-pin 1× M12 connector female, 4-pin, D-coded
1× M12 connector female, 8-pin 1× M12 connector female, 8-pin 1× M12 connector male, 5-pin
1× M12 connector female, 8-pin
2 screws 2 screws 2 screws

112 112 112

48
48

48

38 54 38 54 63 54
5.3 5.3 38
8

5.3
8
8
4

4
4

NODE ID
READY READY
122.7

1 READY
122.7
122.7
137
137

137

RF 2 RF
RF
4 IP ADDRESS
COM COM COM
8 DEFAULT

16 CUSTOM

ETHERNET V DC I/O
RS485/V DC I/O RS485/V DC I/O

Ø 5.3 Ø 5.3
98 98 Ø 5.3
98

■ www.balluff.com 99
BIS M Industrial RFID System
HF long range conveyor antenna

These antannae work with these controllers:


■ BIS M-620-068-A01-00-ST29
■ BIS M-620-067-A01-04-ST30
■ BIS M-626-069-A01-06-ST32

Dimensions
Housing material
Standard Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection to
Connection cable (please order separately)

Appropriate data carrier


Write distance in mm
Read distance in mm
Offset in mm at distance
50 mm
100 mm

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

Recommended accessories round


(please order separately)
Installation note

Description External Antenna Connection Kit


Ordering code BIS00WJ
Part number BIS M-500-PVC-07-A01/02
Please order separately.

100
BIS M Industrial RFID System
HF long range conveyor antenna

13.56 MHz HF
70×500x6 mm
BIS M
PA Industrial
BIS00WN RFID System
BIS M-370-000-A02 Range of
applications
Read/write
–20...+50 °C distances
–40...+85 °C overview
Data carriers
IP 65
Read/write
1× internal RCA jack to processor heads
Extension cable kit BIS M-500-PVC-07-A01/02 Read/write
compact
processors
HF antenna
BIS M-132-03/L-HT

Processors
BIS M-135-03/L

Gateways
Standard
handheld
BIS00YE

BIS00Y5

Access
protection

0...570...127
0...570...127
X Y X Y
±100 ±10 ±100 ±10
±80 ±10 ±80 ±10

541
maximum
backet
dimension

38

373 3.5
maximum
backet
dimension
40
13.1
26

500

65
38

70

76

137.5 Ø5.4

■ www.balluff.com 101
BIS M Industrial RFID System
HF long range antenna

These antannae work with these controllers:


■ BIS M-620-068-A01-00-ST29
■ BIS M-620-067-A01-04-ST30
■ BIS M-626-069-A01-06-ST32

Dimensions
Housing material
Standard Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection to
Connection cable (please order separately)

Appropriate data carrier


Write distance in mm
Read distance in mm
Offset in mm at distance 100 mm
200 mm

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

Processor

Antenna

102
BIS M Industrial RFID System
HF long range antenna

13.56 MHz HF
112×100×6 mm
BIS M
PA Industrial
BIS00WM RFID System
BIS M-371-000-A01 Range of
applications
Read/write
–20...+50 °C distances
overview
–40...+85 °C
Data carriers
IP 65
Read/write
1× internal RCA jack to processor heads
Extension cable kit BIS M-500-PVC-07-A01/02 Read/write
compact
processors
HF antenna
BIS M-132-03/L-HT

BIS M-136-03/L-HT
BIS M-135-03/L/HT

Processors
BIS M-132-03/L

BIS M-135-03/L

BIS M-136-03/L

Gateways
Standard
handheld
BIS00W9
BIS00YE
BIS00YF

BIS00Y5

BIS00Y4

BIS00Y1

Access
protection

0...152 0...152 0...230 0...257 0...216 0...254


0...152 0...152 0...230 0...257 0...216 0...254
±30 ±30 ±35 ±35 ±35 ±40
±10 ±30 ±10 ±30

100 6.2
100

117.1
61.3
12.8

Ø5.1
98
113.4
42
16.9

65

■ www.balluff.com 103
BIS M Industrial RFID System
HF long range antenna

These antannae work with these controllers:


■ BIS M-620-068-A01-00-ST29
■ BIS M-620-067-A01-04-ST30
■ BIS M-626-069-A01-06-ST32

Dimensions
Housing material
Standard Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of Protection per IEC 60529
Connection to
Connection cable (please order separately)

Appropriate data carrier


Write distance in mm
Read distance in mm
Offset in mm at distance 100 mm
200 mm

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

Processor

Antenna

104
BIS M Industrial RFID System
HF long range antenna

13.56 MHz HF
200×200×6 mm
BIS M
PA Industrial
BIS00WL RFID System
BIS M-372-000-A01 Range of
applications
Read/write
–20...+50 °C distances
overview
–40...+85 °C
Data carriers
IP65
Read/write
1× internal RCA jack to processor heads
Extension cable kit BIS M-500-PVC-07-A01/02 Read/write
compact
processors
HF antenna
BIS M-132-03/L-HT

BIS M-135-03/L-HT

BIS M-136-03/L-HT

Processors
BIS M-132-03/L

BIS M-135-03/L

BIS M-136-03/L

Gateways
Standard
handheld
BIS00W9
BIS00YE
BIS00YF

BIS00Y5

BIS00Y4

BIS00Y1

Access
protection

0...216 0...216 0...350 0...381 0...318 0...381


0...216 0...216 0...350 0...381 0...318 0...381
±75 ±75 ±75 ±75 ±75 ±75
±10 ±10 ±75 ±75 ±75 ±75

200 6.2
47.4
47.4
200

61.4

30 16.4
Ø5.1
98 20.5
14.9

113.4
25.5
42

65
Ø3
89.3

■ www.balluff.com 105
BIS M Industrial RFID System
HF long range antenna

These antannae work with these controllers:


■ BIS M-620-068-A01-00-ST29
■ BIS M-620-067-A01-04-ST30
■ BIS M-626-069-A01-06-ST32

Dimensions
Housing material
Standard Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection to
Connection cable (please order separately)

Appropriate data carrier


Write distance in mm
Read distance in mm
Offset in mm at distance 100 mm
200 mm

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

Processor

Antenna

106
BIS M Industrial RFID System
HF long range antenna

13.56 MHz HF
300×300×6 mm
BIS M
PA Industrial
BIS00WK RFID System
BIS M-373-000-A01 Range of
applications
Read/write
–20...+50 °C distances
overview
–40...+85 °C
Data carriers
IP 65
Read/write
1× internal RCA jack to processor heads
Extension cable kit BIS M-500-PVC-07-A01/02 Read/write
compact
processors
HF antenna
BIS M-132-03/L-HT

BIS M-135-03/L-HT

BIS M-136-03/L-HT

Processors
BIS M-132-03/L

BIS M-135-03/L

BIS M-136-03/L

Gateways
Standard
handheld
BIS00W9
BIS00YE
BIS00YF

BIS00Y5

BIS00Y4

BIS00Y1

Access
protection

0...238 0...228 0...380 0...406 0...356 0...432


0...238 0...228 0...380 0...406 0...356 0...432
±100 ±100 ±110 ±110 ±110 ±125
±100 ±100 ±110 ±110 ±110 ±125

300 6.2
47.4

47.4
300

61.4
60.9
13

30 16.4
Ø5.1
101 98
20.6
113.4
42

14.9

65 Ø5.1

89.3

■ www.balluff.com 107
BIS M Industrial RFID System
Serial RS232 processors
Serial RS232

Description
Housing material
Serial RS232 Ordering code
Part number
Supply voltage, Ripple
Current
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Read/write head ports
Service interface
Control inputs
Control outputs
Connection for
Connection type

Accessories included
Connection cable

108
BIS M Industrial RFID System
Serial RS232 processors

13.56 MHz HF
Processor Processor
BIS M
ABS ABS Industrial
BIS00N1 BIS00J0 RFID System
BIS M-6000-007-050-00-ST15 BIS M-6000-007-050-00-ST24 Range of
applications
19.2...28.8 V DC, ≥ 10 % 19.2...28.8 V DC, ≥ 10 % Read/write
24V DC ≤ 400mA 24 V DC ≤ 400mA distances
overview
0...+60 °C 0...+60 °C
Data carriers
0...+60 °C 0...+60 °C
Read/write
IP 65 (with connectors) IP 65 (with connectors) heads
2 external 2 external Read/write
compact
RS232 RS232 processors
1 (optocoupler isolated) 1 (optocoupler isolated) HF antenna
4 Processors
2× read/write heads BIS M-3_ _-001 2× read/write heads BIS M-3_ _-001 Gateways
1× M12 connector male, 5-pin 1× M12 connector male, 5-pin Standard
handheld
1× M12 connector male, 4-pin, B-coded 1× M12 connector male, 8-pin
Access
1× M12 connector male, 4-pin, B-coded protection
Software Software
See page 305/380 for cable options See page 305/380 for cable options

18.5 18.5
9.5

9.5
3 ) max. max.
1,5 Nm 1,5 Nm

4.3 4.3
12.8

12.8
150.0
16.8

12.5 12.5
16.8

150

82.0
71.6

71.6

82

21.5
21.5
14,6

ca 15

45.5 90.0 45.5 90

■ www.balluff.com 109
BIS M Industrial RFID System
Profibus processors

Cost-effective identification –
operate 2 read/write heads simultaneously
■ Selectable division of the data width on the Profibus, 4...128 byte
■ Free assigning of the data width for each read/write head
■ Optimum data speed, internal cycle time
is shorter than the bus activation time
■ Service friendly, all parameter data are stored in
an exchangeable memory
■ Bus address selectable with switches
■ Accepts all read/write heads
Description
Housing material
Profibus Ordering code
Part number
Supply voltage, Ripple
Current
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Read/write head ports
Service interface
Connection for
Connection type

Accessories included
Connection cable

The BIS M-6002 processor features a small form factor and flexible
interface options for use wherever ambient conditions require IP 65
protection. These models are ideal also when no aggressive media
are used with PS plastic. Small, compact, flexible and cost-effective

110
BIS M Industrial RFID System
Profibus processors

In robust metal housing


13.56 MHz HF
Processor Processor
BIS M
ABS Aluminum cast, coated Industrial
BIS00EW BIS00F0 RFID System
BIS M-6002-019-050-03-ST11 BIS M-6022-019-050-03-ST14 Range of
applications
24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 % Read/write
≤ 400 mA ≤ 400 mA distances
overview
0...+60 °C 0...+60 °C
Data carriers
0...+60 °C 0...+60 °C
Read/write
IP 65 IP 65 heads
2 external 2 external Read/write
compact
RS232 RS232 processors
2× read/write heads BIS M-3_ _-001 2× read/write heads BIS M-3_ _-001 HF antenna
1× M12 connector male, 5-pin, B-coded 1× M12 connector male, 5-pin, B-coded Processors
1× M12 connector female, 5-pin, B-coded 1× M12 connector female, 5-pin, B-coded Gateways
1× M12 connector male, 5-pin 2× M12 connector male, 5-pin Standard
handheld
Software GSD file Software GSD file
Access
See page 290/305/380 for cable options See page 290/305/380 for cable options protection

The rugged BIS M-6022 with the die-cast aluminum housing is a


small, flexible processor which is available with various interface
options. Great mechanical stability and high chemical resistance.
Rugged, small and flexible

Recommended accessories 06Z


9
BCC
(please order separately)

5
071
BCC

14
Ordering code BAM0114 C07
BC
Part number BKS 12-CS-01
Threaded cover for M12 connector

■ www.balluff.com 111
BIS M Industrial RFID System
Devicenet processors

Cost-effective identification –
operate 2 read/write heads simultaneously
■ Freely selectable buffer size, 0...256 byte
■ Service friendly, all parameter data are stored in
an exchangeable memory
■ Accepts all read/write heads

Description
Housing material
Devicenet Ordering code
Part number
Supply voltage, Ripple
Current
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Read/write head ports
Service interface
Connection for
Connection type

Accessories included
Connection cable

The BIS M-6003 processor features a small form factor and flexible
interface options for use wherever ambient conditions require IP 65
protection. These models are ideal also when no aggressive media
are used with PS plastic. Small, compact, flexible and cost-effective

112
BIS M Industrial RFID System
Devicenet processors

In robust metal housing


13.56 MHz HF
Processor Processor
BIS M
ABS Aluminum cast, coated Industrial
BIS00EY BIS00F1 RFID System
BIS M-6003-025-050-03-ST12 BIS M-6023-025-050-03-ST13 Range of
applications
24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 % Read/write
≤ 400 mA ≤ 400 mA distances
overview
0...+60 °C 0...+60 °C
Data carriers
0...+60 °C 0...+60 °C
Read/write
IP 65 IP 65 heads
2 external 2 external Read/write
compact
RS232 RS232 processors
2× read/write heads BIS M-3_ _-001 2× read/write heads BIS M-3_ _-001 HF antenna
2× M12 connector male, 5-pin 2× M12 connector male, 5-pin Processors
1× M12 connector female, 5-pin 1× 7/8" connector male, 5-pin Gateways
1× 7/8" connector female, 5-pin Standard
handheld
Software EDS file Software EDS file
Access
See page 296/305/380 for cable options See page 294/305/380 for cable options protection

The rugged BIS M-6023 with the die-cast aluminum housing is


a small, flexible processor which is available with various interface
options. Great mechanical stability and high chemical resistance.
Rugged, small and flexible

06Z9
BCC

070K
BCC

070F
BCC

9
0M0
BCC

■ www.balluff.com 113
BIS M Industrial RFID System
Ethernet/IP processor

In robust metal housing

Description Processor
Housing material Aluminum cast, coated
Ethernet/IP Ordering code BIS00F2
Part number BIS M-6026-034-050-06-ST19
Supply voltage, Ripple 24 V DC ±20 %, ≤ 10 %
Current ≤ 400 mA
Operating temperature 0...+60 °C
Storage temperature 0...+60 °C
Degree of protection per IEC 60529 IP 65
Read/write head ports 2 external
Service interface RS232
Connection for 2× read/write heads BIS M-3_ _-001
Connection type 1× M12 connector female, 4-pin, D-coded
1× M12 connector male, 5-pin
1× M12 connector male, 4-pin
Accessories included Configuration software
Connection cable See page 293/305/380 for cable options

■ Cost-effective identification –
operate 2 read/write heads simultaneously.
■ Rugged processor for Ethernet/IP networks

9
06Z
BCC

1
03Y
BCC

114
Ethernet BIS M Industrial RFID System
Ethernet TCP/IP processor
TCP/IP

13.56 MHz HF
Description Processor
BIS M
Housing material Aluminum, anodized Industrial
Ethernet TCP/IP Ordering code BIS00EP RFID System
Part number BIS M-407-039-003-06-S115 Range of
applications
Supply voltage, Ripple 24 V DC ±20 %, ≤ 10 % Read/write
Current ≤ 150 mA distances
overview
Operating temperature 0...+60 °C
Data carriers
Storage temperature 0...+60 °C
Read/write
Degree of protection per IEC 60529 IP 67 heads
Read/write head ports 1 external Read/write
compact
Service interface none processors
Connection for 1× read/write head BIS M-3_ _-003 HF antenna
Connection type 1× M12 connector female, 4-pin, D-coded Processors
1× M12 connector male, 5-pin Gateways
Standard
handheld
Accessories included Configuration software
Access
Connection cable See page 293/305/380 for cable options protection

■ Small and compact – for one read head


■ Easy to connect to any PC-based controller

For use only with these read heads


■ BIS M-300-003-S115
■ BIS M-301-003-S115
■ BIS M-302-003-S115
■ BIS M-304-003-S115

Suitable connectors
(please order separately)

Ordering code BCC0C5J


Part number BIS C-526-PU-00,6
Order accessories separately! Adapter cable for Ethernet
from M12, D-coded to coupling RJ45 see connectivity section.

■ www.balluff.com 115
BIS M Industrial RFID System
Profinet processors

Rugged processors for Profinet

Description
Housing material
Profinet RT Ordering code
with IRT-capable 2-port switch Part number
Supply voltage, Ripple
Current
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Read/write head ports
Service interface
Connection for
Connection type

Accessories included
Connection cable

116
BIS M Industrial RFID System
Profinet processors

13.56 MHz HF
Processor Processor Processor
BIS M
ABS Aluminum cast, coated Aluminum cast, coated Industrial
BIS00L7 BIS00KZ BIS00TW RFID System
BIS M-6008-048-050-06-ST23 BIS M-6028-048-050-06-ST22 BIS M-6028-048-050-06-ST28 Range of
applications
24 V DC ±10 %, ≤ 10 % 24 V DC ±10 %, ≤ 10 % 24 V DC ±10 %, ≤ 10 % Read/write
≤ 400 mA ≤ 400 mA ≤ 400 mA distances
overview
0...+60 °C 0...+60 °C 0...+60 °C
Data carriers
0...+60 °C 0...+60 °C 0...+60 °C
Read/write
IP 65 IP 65 IP 65 heads
2 external 2 external 2 external Read/write
compact
RS232 internal RS232 RS232 processors
2× read/write heads BIS M-3_ _-001 2× read/write heads BIS M-3_ _-001 2× read/write heads BIS M-3_ _-001 HF antenna
1× M12 connector male, 5-pin 1× Push-pull AIDA connector, 5-pin 1× 7/8" connector male, 5-pin Processors
2× M12 connector female, 4-pin, D-coded 2× Push-pull RJ45 AIDA connector, 8-pin 2× M12 connector female, 5-pin, D-coded Gateways
1× M12 connector male, 4-pin 1× M12 connector male, 4-pin Standard
handheld
Configuration software Configuration software Configuration software
Access
See page 292/305/380 for cable options See page 305/380 for cable options See page 292/305/380 for cable options protection

60 100
21 63

15
145
160
M4
15

15

21 1 15
20

The robust version solution for connection to


Profinet with AIDA standard (Automation Initiative
of German Domestic Automobile Manufacturers)

■ www.balluff.com 117
BIS M Industrial RFID System
Processor for Mitsubishi processor

■ Suitable for every environment


■ Identification without diversions

Description Processor
Housing material Plastic
CPU for MELSEC-Q Ordering code BIS00HM
bus interface by Mitsubishi Part number BIS M-688-001
Supply voltage, Ripple 21.6...26.4 V DC, inclusive
Current < 500mA
Operating temperature 0...+55 °C
Storage temperature –25...+75 °C
Degree of protection per IEC 60529 IP 20
Read/write head ports Up to 2
Connection type Bus direct

98
14
90.5 27.4

118
BIS M Industrial RFID System
CC-Link processor

■ Flexible use due to a wide range of different combinations


of data carriers and antennas
■ Up to two antennas per processor
■ Tested quality with CC-Link certificate
■ Make use of timesaving features: Connector-based cabling, robust
housing that is easy to install, preassembled function modules and
diagnostics function that enable easy commissioning

The CC Link field bus protocol ensures quick, robust communication


between different stations. The new BIS M-699 processor can now 13.56 MHz HF
be used directly in the field. Conformity with standards ISO 15693 Description Processor
BIS M
and 14443 as well as globally approved frequency of 13.56 MHz Housing material Aluminum cast, coated Industrial
Ordering code BIS00LY RFID System
allow worldwide use of this CC-Link processor.
Part number BIS M-699-052-050-03-ST11 Range of
applications
Supply voltage, Ripple LPS CL. 2 supplied only, Read/write
21.6...26.4 V DC, ≥10% distances
overview
Current ≤ 800 mA
Data carriers
Operating temperature 0...+55 °C
Read/write
Storage temperature –25...+75 °C heads
Degree of protection per IEC 60529 IP 65 (with connectors) Read/write
compact
Read/write head ports 2 processors
Service interface CC-Link HF antenna
Connection for 2 read/write heads Processors
BIS M-3_ _-001 Gateways
Connection type 2× M12 connector male, 5-pin Standard
handheld
1× M12 connector female, 5-pin
Access
Connection cables See page 305/380 for cable options protection

21

13
X1

X2

185
200
X3

M4

63
60 19 100

The HF processor BIS M-699 with 13.56 MHz is used directly in


the field in all applications where robust controllers are connec-
ted directly to CC-Link. Thanks to the wide variety of special
data carriers, for example, optimized for flush installation in me-
tal, for temperatures up to 200 °C or for the maximum distance,
this HF processor can be used in almost all industrial sectors.

■ www.balluff.com 119
BIS M Industrial RFID System
BIS V processors – new generation

A new generation system for more flexible RFID:


Combine up to four low and high frequency read/write heads
with I/O in one device.
The BIS V Radio Frequency Identification (RFID) system is founded
on a new generation of RFID processors that maximize your flexibility
by providing a single device for both low frequency 125Khz and high
frequency 13.56Mhz read/write heads with an IO-Link master port.
Combining up to four heads on either frequency with local analog,
valve manifold or I/O access/control provides a solution you can ap-
ply to many types of RFID applications.This can save cost and time
using a single processor platform across your application installation Description
base. The BIS V system also allows you to draw on a single proces- Housing material
sor family with a wide array of read/write head and RFID tag options Profibus Ordering code
for both manufacturing and logistics solutions. Part number
EtherCAT Ordering code
The BIS V RFID system offers a higher level of performance than Part number
other systems to solve today’s industrial applications. Designed to CC-Link Ordering code
maximize performance while improving usability out on the line, the Part number
BIS V processor provides a functional display and LED’s making sta- Supply voltage, Ripple
tus and setup easier. And a USB service interface makes connection Current
for setup to today’s PC’s simple. The BIS V offers these additional Operating temperature
functions: Storage temperature
■ Four asynchronous 125Khz and 13.56Mhz read/write Protection per IEC 60529
antenna channels. Read/write head ports
■ LCD display with control buttons for setting and displaying Service interface
the Profibus address and data carrier/tags UID. Control inputs / outputs
■ An integrated IO-Link master port for connecting discrete Connection for
or analog I/O, or valve manifolds. Connection type
■ Intelligent power plug option for saving parameters on the device.
■ Industrial IP rated metal housing for any application environment.
■ Flexible mounting options for hard-point or DIN rail.

Accessories included
Connection cable

The following communication options will become available in 2013:


Ethernet/IP, CC-Link, Profinet, and Ethernet TCP/IP

The compact EMC-protected metal housing with small dimensions


(170×60×40 mm) is perfectly integrated and simple to mount. In control
cabinets or in the field up to IP 65, on a top-hat rail, or on a profile.

Increment/ Decrement/
Cancel control button Enter control button

Display

Status LEDs

Read/write head Read/write head


connection 1 connection 2

The industrial RFID system BIS V was developed and qualified according
to the principles of GAMP® 5. You can obtain more detailed information upon
request at rfidpharma@balluff.com
Read/write head Read/write head
connection 3 connection 4

USB and IO-Link


connection
7/8" power plug

Bus out Bus in

120
BIS M Industrial RFID System
BIS V processors – new generation

13.56 MHz HF
Profibus processor EtherCAT processor CC-Link processor
BIS M
Aluminum cast, coated Aluminum cast, coated Aluminum cast, coated Industrial
BIS00T3 RFID System
BIS V-6102-019-C001 Range of
applications
BIS00U9 Read/write
BIS V-6110-063-C002 distances
overview
BIS010P
Data carriers
BIS V-6111-073-C003
Read/write
24V DC ±10% LPS Class 2, ≤ 10% 24V DC ±10% LPS Class 2, ≤ 10% 24V DC ±10% LPS Class 2, ≤ 10% heads
≤ 2 A ≤ 2 A ≤ 2 A Read/write
compact
0...+60 °C 0...+60 °C 0...+60 °C processors
0...+60 °C 0...+60 °C 0...+60 °C HF antenna
IP 65 IP 65 IP 65 Processors
4× external 4× external 4× external Gateways
IO-Link 1.1, USB 2.0 IO-Link 1.1, USB 2.0 IO-Link 1.1, USB 2.0 Standard
handheld
IO-Link based IO-Link based IO-Link based
Access
4 Read/write head BIS VM-3_ _ _ 4 Read/write head BIS VM-3_ _ _ 4 Read/write head BIS VM-3_ _ _ protection
4× M12 connector female, 5-pin 4× M12 connector female, 5-pin 4× M12 connector female, 5-pin
1× 7/8" connector male, 5-pin 1× 7/8“ connector male, 5-pin 1× 7/8“ connector male, 5-pin
1× M12 connector male, 5-pin 2× M12 connector female, 4-pin 1× M12 connector male, 5-pin
1× M12 connector female, 5-pin 1× M12 connector female, 3-pin 1× M12 connector female, 5-pin
1× M12 connector female, 3-pin 1× M12 connector female, 3-pin
Configuration software Configuration software Configuration software
See page 274/279/290/306 for cable options See page 274/279/306 for cable options See page 274/279/298/306 for cable options

■ www.balluff.com 121
BIS M Industrial RFID System
Gateways
Subnet16™

The Gateway is designed for point-to-point or bus network RFID


applications. The Gateway connects directly to a serial communica-
tions port on a host computer via an RS232 or bus communication
compatible interfaces.

It supports Subnet16™ Multidrop bus architecture, a subnetwork


of up to sixteen Balluff RFID compact processors or HF long range
processors, through an RS485 interface connection.

Dimensions
Housing material
RS232 Ordering code
Part number
Ethernet/IP Modbus TCP, TCP/IP Ordering code
Part number
Profibus Ordering code
Part number
Ethernet TCP/IP Ordering code
Part number
Supply voltage, Ripple
Operating temperature
Degree of protection per IEC 60529
Service interface
Connection for

Accessories (please order separately)

For installation pay attention to Basic Information chapter.

Read/write compact processors see on page 82,


or long range processors from page 110.

122
BIS M Industrial RFID System
Gateways

Subnet16™ Subnet16™ Subnet16™ Subnet16™


13.56 MHz HF
89×76×32 mm 89×76×32 mm 89×76×32 mm 89×76×32 mm
BIS M
Aluminum Aluminum Aluminum Aluminum Industrial
BAE00JL RFID System
BIS Z-GW-001-RS232 Range of
applications
BAE00JJ Read/write
BIS Z-GW-001-IND distances
overview
BAE00JK
Data carriers
BIS Z-GW-001-PBS
Read/write
BAE00JM heads
BIS Z-GW-001-TCP Read/write
compact
10...30 V DC by net 10...30 V DC by net 10...30 V DC by net 10...30 V DC by net processors
0...+50 °C 0...+50 °C 0...+50 °C 0...+50 °C HF antenna
IP 30 IP 30 IP 30 IP 30 Processors
USB Gateways
1× M12 connector male, 8-pin (RS232) 1× RJ45 connector (Ethernet) 1× Sub-D connector female, 9-pin (Profibus) 1× RJ45 connector (Ethernet) Standard
handheld
1× M12 connector female, 5-pin (RS485) 1× M12 connector female, 5-pin (RS485) 1× USB, Type-B 1× M12 connector female, 5-pin (RS485)
Access
1× M12 connector female, 5-pin (RS485) protection
Accessories on page 288/303 Accessories on page 303 Accessories on page 303 Accessories on page 303

■ www.balluff.com 123
BIS M Industrial RFID System
Standard handheld

For enhanced operating convenience


Allows portable writing and reading of BIS M data carriers.
Easy operation thanks to:
■ Touchscreen with large Windows CE® color display
■ Pre-installed Balluff software and keyboard or stylus

Ideal for poor light conditions and challenging environments. Data


transfer via optional Bluetooth or wired USB. The handheld is also
modular for expandability.

Additional convenience Version


A pistol grip is provided for ergonomic comfort. Function
Housing material
Standard Ordering code
Part number
Standard + WLAN module Ordering code
Part number
Standard + 1D code reader Ordering code
Part number
Standard + 2D code reader Ordering code
Part number
Standard + ID code reader + WLAN Ordering code
Part number
Standard +2D code reader + WLAN Ordering code
Part number
Keyboard
Display
Supply voltage
Capacity
Interface
Working temperature
Degree of protection per IEC 60529
Read/write head option
Accessories included
Appropriate data carrier

Please order additional accessories separately

Standard handheld BIS M-87_-1-008-X-00_


includes charger and stylus.

Antenna type:

rod

round

Recommended accessories
(please order separately)

Description Pistol grip option Optional docking station


with power supply
Ordering code FHW0004 FHW0003
Part number 11023836 11023834

124
BIS M Industrial RFID System
Standard handheld

13.56 MHz HF
General purpose Rod Tool ID
BIS M
Read/write Read/write Read/write Industrial
ABS ABS ABS RFID System
BAE00A1 BAE00CM BAE00CA Range of
applications
BIS M-870-1-008-X-000 BIS M-871-1-008-X-000 BIS M-873-1-008-X-000 Read/write
BAE00F0 distances
overview
BIS M-870-1-008-X-001 BIS M-871-1-008-X-001 BIS M-873-1-008-X-001
Data carriers
Read/write
BIS M-870-1-008-X-002 BIS M-871-1-008-X-002 BIS M-873-1-008-X-002 heads
BAE00H9 Read/write
compact
BIS M-870-1-008-X-003 BIS M-871-1-008-X-003 BIS M-873-1-008-X-003 processors
BAE00CC BAE00E9 HF antenna
BIS M-870-1-008-X-004 BIS M-871-1-008-X-004 BIS M-873-1-008-X-004 Processors
Gateways
BIS M-870-1-008-X-005 BIS M-871-1-008-X-005 BIS M-873-1-008-X-005 Standard
handheld
52 buttons, alphanumeric 52 buttons, alphanumeric 52 buttons, alphanumeric
Access
TFT Touchscreen display TFT Touchscreen display TFT Touchscreen display protection
3.7 V rechargeable battery pack 3.7 V rechargeable battery pack 3.7 V rechargeable battery pack
4000 mA/h 4000 mA/h 4000 mA/h
RS232/Balluff Dialog RS232/Balluff Dialog RS232/Balluff Dialog
–10...+50 °C –10...+50 °C –10...+50 °C
IP 65 IP 65 IP 65
Integrated Integrated Integrated
Charging power supply and stylus Charging power supply and stylus Charging power supply and stylus
for BIS M-Data carrier with for BIS M-Data carrier with rod antenna for BIS M-Data carrier with
round coil Ø ≥ 35 mm round coil Ø ≤ 34 mm
Docking station and pistol grip Docking station and pistol grip Docking station and pistol grip

100 51 100 51 100 51

Ø14.5
20
265

265

265

■ www.balluff.com 125
BIS M Industrial RFID System
Access protection

Access protection
And here's how it works: Individual access codes are allocated via
programmable data keys, which can then be disabled to prevent
further programming.
Unauthorized personnel cannot manipulate the data key as a result.
The data key is read via an antenna fitted to a special bracket. The
processor unit then issues the data.
Different interfaces such as serial, Profibus, Devicenet, Ethernet/IP
or parallel interfaces enable simple connection to the monitored
system. Available for systems BIS C, BIS L and BIS M.
Version
The benefits Use
The programmable data key allows upgrades or replacements Housing material
without requiring modifications to the system software. End users Ordering code
are independent of system providers. The access system is easy Part number
to integrate in read/write stations that already use an identification Operating temperature
system. Simply connect the access monitoring antenna to the se- Storage temperature
cond channel on the existing processor unit. Hardware expenses are Degree of protection per IEC 60529
reduced to a minimum and software only requires slight modification
in order to process both channels.

Electronic key for access control.


Easy to implement using the "RFID key".

126
BIS M Industrial RFID System
Access protection

13.56 MHz HF
Access protection Data carrier and bracket
BIS M
Attachment for read/write head BIS M-304 Used with BIS Z-ZA-001 Industrial
POM and PA 6.6 POM and PA 12 RFID System
BAM012N BIS0049 Range of
applications
BIS Z-ZA-001 BIS M-122-01/A-ZC1 Read/write
0...+70 °C –25...+70 °C distances
overview
–20...+85 °C –25...+85 °C
Data carriers
IP 67
Read/write
heads
Read/write
Sensing
compact
face
processors
HF antenna
Processors
Gateways
Standard
handheld
Access
protection

■ www.balluff.com 127
BIS C
Industrial
RFID
70 kHz LF
System
Inductive Identification
In a wide range of applications: BIS C is particularly powerful and
flexible for the reliable identification of tools in machining centers that
use large amounts of coolant and lubricants and when sterilising
items at high temperatures in autoclaves.

Host
controller
PLC, PC
parallel, serial
Profibus
Devicenet
Ethernet

parallel, serial
Profibus
Devicenet
Ethernet

serial for
Up/Downloading

Interface
variations

Processors
Handy
Programmer

Windows®
based handheld
with integrated
read/write head

optional external
read/write head

Read/write
heads

Data carriers

128
BIS C Industrial RFID System
Inductive identification

Range of applications 130


Read/write distances overview 132
Data carriers read/write 134
Read/write heads 140
Data couplers 154
8-bit processor for read-only mode 156
Processors Serial RS232 158
Parallel 160
Profibus 162
Devicenet 166
Ethernet/IP 170
Ethernet TCP/IP 171
Profinet 172
Standard handheld 174
Read/write heads for handy programmers and read/write gun 176 70 kHz LF
Handy programmer 278
Read/write gun 180
Access protection 182

Basic information
and definitions
can be found on
page 352

■ www.balluff.com 129
BIS C Industrial RFID System
Range of applications

The versatile BIS C is ideal for a wide range of applications. Select


the most suitable BIS C system for your application from the table.

Data carrier

Page
BIS0002 BIS C-100-05/A 135
BIS0004 BIS C-103-05/A 134
BIS0006 BIS C-104-11/A 136
BIS0007 BIS C-104-32/A 136
BIS0009 BIS C-105-05/A 134
BIS000C BIS C-108-05/L 136
BIS000H BIS C-108-11/L 136
BIS000K BIS C-108-32/L 136
BIS000F BIS C-108-05/L-SA2 139
BIS000J BIS C-108-11/L-SA2 139
BIS000M BIS C-117-05/A 135
BIS000N BIS C-117-05/L 135
BIS000R BIS C-117-11/L 135
BIS000T BIS C-121-04/L 134
BIS000W BIS C-121-04/L-SA1 138
BIS0011 BIS C-122-04/L 134
BIS0015 BIS C-122-11/L 134
BIS0017 BIS C-127-05/L 137
BIS0019 BIS C-128-05/L 135
BIS001C BIS C-128-11/L 135
BIS001E BIS C-130-05/L 135
BIS001H BIS C-130-05/L-SA1 138
BIS001Z BIS C-133-05/L 139
BIS C-133-11/L 139
BIS0020 BIS C-134-05/L-H120 139
BIS0021 BIS C-134-11/L 139
BIS00J4 BIS C-140-05/L-M6 139
BIS00J2 BIS C-140-05/L-M8 139
BIS00J3 BIS C-140-11/L-M6 139
BIS00J1 BIS C-140-11/L-M8 139
BIS0028 BIS C-150-05/A 137
BIS002A BIS C-150-11/A 137
BIS002E BIS C-150-32/A 137
BIS002K BIS C-190-05/L 137
BIS002M BIS C-190-11/L 137
BIS002N BIS C-190-32/L 137
BIS002P BIS C-191-05/L 137
BIS002R BIS C-191-11/L 137

130
BIS C Industrial RFID System
Range of applications

Tools Production Intralogistics Access and


object control

Access and entry control


Closed logistics circuits
conveying systems

retrieval equipment

Driverless vehicles

Object detection
Data storage on
machine tools

management

Storage and
Tool and die

Assembly

Long distances (> 16 mm)


70 kHz LF
Retainer/workpiece carrier

Retainer/workpiece carrier

For harsh environments


Reliable access control
Workpiece carrier skid

BIS C Industrial

Installation in metal
RFID System

Dynamic or static
Guiding, steering
Tool holder collar

Process access
On component
Retention knob

Range of

In component
applications
Identification

Read/write
Read/write

EEPROM
distances
On part
On tool

Part ID
Pallets

Pallets

FRAM
overview
Dies

Data carriers
read/write
■ ■ ■ ■ ■ ■ ■ ■ ■ Read/write
heads
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Data
■ ■ ■ ■ ■ ■ ■ ■ ■ couplers
■ ■ ■ ■ ■ ■ ■ ■ ■ 8-bit
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ processor
for read-only
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ mode
■ ■ ■ ■ ■ ■ ■ ■ ■ Processors
■ ■ ■ ■ ■ ■ ■ ■ ■ Standard
handheld
■ ■ ■ ■ ■ ■ ■
Read/write
■ ■ ■ ■ ■ ■ ■ heads
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ for handy
programmers
■ ■ ■ ■ ■ ■ ■ ■ Handy
■ ■ ■ ■ ■ ■ ■ ■ programmer
■ ■ ■ ■ ■ ■ ■ ■ ■ Read/write
gun
■ ■ ■ ■ ■ ■
Access
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ protection
■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■

■ www.balluff.com 131
BIS C Industrial RFID System
Read/write distances overview

Mounting Data carrier 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 90 100 mm


BIS C-300-PU1-_ _
BIS C-306-PU1-_ _
BIS C-100-05/A 0...4
BIS C-103-05/A 0...3.5
BIS C-105-05/A 0...3.5
BIS C-121-04/L 0...2
BIS C-121-04/L-SA1 0...1.2
BIS C-122-04/L 0...2.5
BIS C-130-05/L 0...4
BIS C-134-_ _-L 0...3
BIS C-130-05/L 0...4
BIS C-130-05/L-SA1 0...4
BIS C-191-_ _/L 0...3.5
BIS C-140-_ _/L-M_ 0...3
BIS C-302-PU1-_ _
BIS C-100-05/A 0...4
BIS C-103-05/A 0...3
BIS C-105-05/A 0...3
BIS C-121-04/L 0...1.5
BIS C-121-04/L-SA1 0...0.7
BIS C-122-04/L 0...2
BIS C-130-05/L 0...3.5
BIS C-130-05/L-DB-002 0...4
BIS C-130-05/L-SA1 0...4
BIS C-191-_ _/L 0...3
BIS C-305-PU1-_ _
BIS C-100-05/A 0...4
BIS C-103-05/A 0...5
BIS C-105-05/A 0...5
BIS C-108-_ _/L 0...6
BIS C-108-_ _/L-SA2 0...6
BIS C-117-05/A 1...8
BIS C-117-05/L 0...7
BIS C-121-04/L 0...2
BIS C-121-04/L-SA1 0...1.2
BIS C-122-04/L 0...2.5
BIS C-117-05/A 0...10
BIS C-128-05/L 0...6
BIS C-130-05/L 0...7
BIS C-130-05/L-SA1 0...7
BIS C-134-11/L 0...6
BIS C-140-_ _/L-M_ 0...4.5
BIS C-319-PU1-_ _
BIS C-108-_ _/L 0...14
BIS C-117-05/L 0...15
BIS C-130-05/L 0...13
BIS C-130-05/L-SA1 0...13
BIS C-134-11/L 0...12
BIS C-191-_ _/L 0...11
BIS C-326-PU1_ _
BIS C-117-05/L 0...18
BIS C-128-_ _/L 0...15
BIS C-128-_ _/L 0...12.5
BIS C-130-_ _/L 0...13
BIS C-130-05/L-SA1 0...13
BIS C-133-_ _/L 0...12
BIS C-134-11/L 0...12
BIS C-190-_ _/L 0...18
BIS C-315-PU1-_ _
BIS C-104-_ _/A 1...13
BIS C-108-_ _/L 2...16
BIS C-108-_ _/L-SA2 2...16
BIS C-117-05/A 0...15
BIS C-117-05/L 0...18
BIS C-127-05/L 10...30
BIS C-128-_ _/L 0...18
BIS C-130-05/L 0...18
BIS C-133-_ _/L 0...15
BIS C-134-11/L 0...16
BIS C-190-_ _/L 0...20
BIS C-310-PU1-_ _
BIS C-104-_ _/A 1...11
BIS C-104-_ _/A 0...12
BIS C-108-_ _/L 0...12
BIS C-108-_ _/L-SA2 0...11
BIS C-117-05/A 1...12
BIS C-117-05/L 0...13
BIS C-128-_ _/L 0...8
BIS C-128-_ _/L 0...13
BIS C-130-05/L 0...11
BIS C-130-05/L-SA1 0...8
BIS C-133-_ _/L 0...10
BIS C-134-11/L 0...10
BIS C-190-_ _/L 0...11
BIS C-191-_ _/L 0...10
BIS C-140-_ _/L-M_ 0...7

flush in steel non-flush on steel non-metal

132
BIS C Industrial RFID System
Read/write distances overview

Mounting Data carrier 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 90 100 mm


BIS C-319/_ _-S4
BIS C-108-_ _/L 0...14
BIS C-117-05/L 0...15
BIS C-130-05/L 0...13
BIS C-130-05/L-SA1 0...13
BIS C-134-_ _/L 0...12
BIS C-191-_ _/L 0...11
BIS C-325/_ _-S4
BIS C-100-05/A 0...4
BIS C-121-04/L-SA1 0...1.7
BIS C-122-_ _/L 0...2.5
BIS C-130-05/L 0...4
BIS C-130-05/L-SA1 0...3
BIS C-134-_ _L 0...4
BIS C-191-_ _/L 0...3
BIS C-140-_ _/L-M_ 0...5
BIS C-323/_ _-S4
BIS C-104-_ _/A 1...11
BIS C-104-_ _/A 0...12
BIS C-108-_ _/L 0...12
BIS C-108-_ _/L-SA2 0...11
BIS C-117-05/A 1...12 70 kHz LF
BIS C-117-05/L 0...13
BIS C Industrial
BIS C-128-_ _/L 0...8 RFID System
BIS C-128-_ _/L 0...13
BIS C-130-05/L 0...11 Range of
applications
BIS C-130-05/L-SA1 0...8
BIS C-133-_ _/L 0...10 Read/write
distances
BIS C-134-_ _/L 0...10 overview
BIS C-190-_ _/L 0...11
Data carriers
BIS C-191-_ _/L 0...10 read/write
BIS C-140-_ _/L-M_ 0...7
BIS C-315/_ _-S4 Read/write
heads
BIS C-104-_ _/A 1...13
BIS C-108-_ _/L 2...16 Data
couplers
BIS C-108-_ _/L-SA2 2...16
BIS C-117-05/A 0...15 8-bit
processor
BIS C-117-05/L 0...20 for read-only
BIS C-127-05/L 10...30 mode
BIS C-128-_ _/L 0...18
Processors
BIS C-130-05/L 0...18
BIS C-133-_ _/L 0...15 Standard
handheld
BIS C-134-11/L 0...16
BIS C-190-_ _/L 0...20 Read/write
heads
BIS C-324/_ _-S4 for handy
BIS C-104-_ _/A 1...11 programmers
BIS C-104-_ _/A 0...12
Handy
BIS C-108-_ _/L 0...12 programmer
BIS C-108-_ _/L-SA2 0...11
Read/write
BIS C-117-05/A 0...12 gun
BIS C-117-05/L 0...13
Access
BIS C-128-_ _/L 0...8 protection
BIS C-128-_ _/L 0...13
BIS C-130-05/L 0...11
BIS C-130-05/L-SA1 0...8
BIS C-133-_ _/L 0...10
BIS C-134-11/L 0...10
BIS C-190-_ _/L 0...11
BIS C-191-_ _/L 0...10
BIS C-140-_ _/L-M_ 0...7
BIS C-327-_ _
BIS C-108-05/L 0...8
BIS C-128-11/L 0...8
BIS C-190-32/L 0...8
BIS C-328/_ _-S49
BIS C-122-04/L 0...3
BIS C-122-11/L 0...3
BIS C-318-PU1-_ _
BIS C-108-_ _/L-SA2 0...6
BIS C-108-_ _/L 0...7
BIS C-117-05/L 0...7
BIS C-127-05/L 10...35
BIS C-128-_ _/L 0...7.5
BIS C-190-_ _/L 0...8
BIS C-351-PU1-_ _
BIS C-150-05/A 0...45
BIS C-150-11/A 0...45
BIS C-150-32/A 0...45
BIS C-350-00.3
BIS C-150-05/A 0...100
BIS C-150-11/A 0...100
BIS C-150-32/A 0...100
BIS C-355/05-S92
BIS C-150-05/A 0...35
BIS C-150-11/A 0...35
BIS C-150-32/A 0...35

■ www.balluff.com 133
BIS C Industrial RFID System
Data carriers read/write
Tool ID

Dimensions Ø 9×4.5 mm Ø 10×4.5 mm Ø 12×8 mm Ø 12×6 mm


Housing material EP EP EP EP
Weight 0.5 g 0.7 g 1.8 g 1.2 g

BIS C read/write
511 bytes Ordering code BIS000T BIS0011
Part number BIS C-121-04/L BIS C-122-04/L
1023 bytes Ordering code BIS0004 BIS0009
Part number BIS C-103-05/A BIS C-105-05/A
2047 bytes Ordering code BIS0015
Part number BIS C-122-11/L
Operating temperature 0...+70 °C 0...+70 °C –30...+70 °C –30...+70 °C
Storage temperature –30...+85 °C* –30...+85 °C* –30...+85 °C* –30...+85 °C*
Degree of protection per IEC 60529 IP 68 IP 68 IP 68 IP 68

Appropriate read/write head with max. read/write distance


Mounting
BIS C-300 2 mm 3 mm 2.5 mm 3 mm 3.5 mm 4 mm 3.5 mm 4 mm
BIS C-302 1.5 mm 2.5 mm 2 mm 2.5 mm 3 mm 3.5 mm 3 mm 3.5 mm
BIS C-305 2 mm 3 mm 2.5 mm 3 mm 5 mm 6 mm 5 mm 6 mm
BIS C-306 2 mm 3 mm 2.5 mm 3 mm 3.5 mm 4 mm 3.5 mm 4 mm
BIS C-310
BIS C-315
BIS C-318
BIS C-319
BIS C-323
BIS C-324
BIS C-325 1.7 mm 3 mm 2.5 mm 3 mm 4.5 mm 5 mm 4.5 mm 5 mm
BIS C-326
BIS C-327
BIS C-328 3 mm

For installation pay attention


to Basic Information chapter. Sensing Sensing Sensing Sensing
face face face face
* also available for up to
+ 120 °C on request

Mounting:
glue into hole Ø 10 H11
flush in steel glue into hole Ø 9 H11 glue into hole Ø 12 H11 glue into hole Ø 12 H11
DIN 69 873
non-flush on steel

non-metal

Antenna type:

rod

round

134
BIS C Industrial RFID System
Data carriers read/write

Ø 16×7 mm Ø 16×10.5 mm Ø 26×6 mm Ø 30×16 mm Ø 30×16 mm


EP PA 66 EP PBT PBT
2g 3g 6g 23 g 5.5 g

70 kHz LF
BIS C Industrial
RFID System
BIS001E BIS0002 BIS0019 BIS000M BIS000N Range of
BIS C-130-05/L BIS C-100-05/A BIS C-128-05/L BIS C-117-05/A BIS C-117-05/L applications
BIS001C BIS000R Read/write
distances
BIS C-128-11/L BIS C-117-11/L overview
–30...+70 °C 0...+70 °C –20...+70 °C –30...+70 °C –30...+70 °C Data carriers
read/write
–30...+85 °C* –20...+85 °C –30...+85 °C* –30...+85 °C –30...+85 °C
Read/write
IP 68 IP 68 IP 68 IP 68 IP 68 heads
Data
couplers
8-bit
processor
4 mm 4 mm 4 mm 4 mm for read-only
mode
4 mm 4 mm
Processors
6 mm 7 mm 4 mm 4 mm 3.5 mm (1) 6 mm (1) 8 mm 10 mm 7 mm
Standard
4 mm 4 mm 4 mm 4 mm handheld
11 mm 8 mm 3 mm 2 mm 13 mm 13 mm Read/write
heads
18 mm 18 mm 15 mm 22 mm 20 mm for handy
7.5 mm 7 mm programmers
6 mm 13 mm 14 mm 13 mm 16 mm 8 mm 15 mm Handy
programmer
11 mm 8 mm 13 mm 12 mm 13 mm 13 mm
Read/write
8 mm 13 mm 12 mm 13 mm 13 mm gun
4 mm 5 mm 4 mm 4 mm Access
protection
13 mm 15 mm 18 mm
8 mm

Sensing Sensing Sensing Sensing Sensing


face face face face face

Contact
surface
glue into hole Ø 16 H11

for
wrench

Recommended accessories Compatible screws for BIS C-128-...


data carriers: DIN EN ISO 2009 M5
(please order separately) (countersunk slot head screw)
DIN EN ISO 7046-1 M5
(countersunk Philips head screw)
Screw tightening torque 2.5 Nm
(1) BISC-305, only if BIS C-128_ _
is attached using plastic screw.
Ordering code 710691
Part number MONTAGESCHLUESSEL BIS CODETRAEGER
Installation tool for BIS C-100-05/A data carrier

■ www.balluff.com 135
BIS C Industrial RFID System
Data carriers read/write
Palletizing
and Logistics

Dimensions Ø 30×35 mm 52×32×11 mm


Housing material Brass, coated PBT
Weight 54 g 28 g

BIS C read/write
1023 bytes Ordering code BIS000C
Part number BIS C-108-05/L
2047 bytes Ordering code BIS0006 BIS000H
Part number BIS C-104-11/A BIS C-108-11/L
8 kBytes Ordering code BIS0007 BIS000K
Part number BIS C-104-32/A BIS C-108-32/L
Operating temperature –30...+70 °C –30...+70 °C
Storage temperature –30...+85 °C –30...+85 °C
Degree of protection per IEC 60529 IP 67 IP 68

Appropriate read/write head with max. read/write distance


Mounting
BIS C-300
BIS C-305 6 mm
BIS C-306
BIS C-310 11 mm 12 mm 5 mm 12 mm
BIS C-315 13 mm 14 mm 10 mm 16 mm
BIS C-318 7 mm
BIS C-319 11 mm 14 mm
BIS C-323 11 mm 12 mm 12 mm
BIS C-324 11 mm 12 mm 12 mm
BIS C-325
BIS C-326
BIS C-327 8 mm
BIS C-350
BIS C-351

For installation pay attention to Basic Information chapter. Sensing Sensing


face face
Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round Screw tightening torque 40 Nm

Caution!
Reading or writing can be performed
on one active surface as desired.

136
BIS C Industrial RFID System
Data carriers read/write

85×53×4.5 mm 80×40×22 mm 34×34 mm 12.5×12.5 mm


ABS POM PBT PBT
30 g 75 g 29 g 10 g

70 kHz LF
BIS0017 BIS0028 BIS002K BIS002P
BIS C Industrial
BIS C-127-05/L BIS C-150-05/A BIS C-190-05/L BIS C-191-05/L RFID System
BIS002A BIS002M BIS002R Range of
BIS C-150-11/A BIS C-190-11/L BIS C-191-11/L applications
BIS002E BIS002N Read/write
distances
BIS C-150-32/A BIS C-190-32/L overview
0...+60 °C –30...+70 °C –30...+70 °C –30...+70 °C Data carriers
read/write
–20...+60 °C –30...+85 °C –30...+85 °C –30...+85 °C
Read/write
IP 65 IP 68 IP 68 IP 68 heads
Data
couplers
8-bit
processor
3.5 mm for read-only
mode
Processors
3.5 mm
Standard
11 mm 10 mm handheld
30 mm 20 mm Read/write
heads
25 mm 8 mm for handy
11 mm programmers
11 mm 10 mm Handy
programmer
11 mm 10 mm
Read/write
3.5 mm gun
18 mm Access
protection
8 mm
100 mm
50 mm

Write/read Sensing
axis Sensing
Write/read face
face
axis

Sensing Sensing
face face

Screw tightening torque 1.5 Nm, Screw tightening torque 1.5 Nm,
anti-torquing installation provided anti-torquing installation provided
by straight pin Ø 4 mm per by straight pin Ø 3 mm per
DIN EN 22338; DIN EN 28734 DIN EN 22338; DIN EN 28734

■ www.balluff.com 137
BIS C Industrial RFID System
Data carriers read/write
Speciality

Dimensions Ø 11×13 mm Ø 15.5×7 mm


Housing material Glass PBT
Weight 0.9 g 28 g

BIS C read/write
511 bytes Ordering code BIS000W
Part number BIS C-121-04/L-SA1
1023 bytes Ordering code BIS001H
Part number BIS C-130-05/L-SA1
2047 bytes Ordering code
Part number
Operating temperature +10...+70 °C –30...+70 °C
Storage temperature +10...+126 °C –30...+85 °C
Degree of protection per IEC 60529/DIN 40050 IP 68 IP 68
Suitable for use in autoclaves use in vacuum

Appropriate read/write head with max. read/write distance


Mounting
BIS C-300 1.2 mm 4 mm 4 mm
BIS C-302 0.7 mm
BIS C-305 1.2 mm 6 mm 7 mm
BIS C-306 1.2 mm 4 mm 4 mm
BIS C-310 1.7 mm 8 mm 11 mm
BIS C-315
BIS C-318
BIS C-319 7 mm 13 mm
BIS C-323 8 mm 11 mm
BIS C-324 8 mm 11 mm
BIS C-325 4 mm 5 mm
BIS C-326 13 mm

For installation pay attention to Basic Information chapter.


Sensing Sensing
face face
* also available for up to + 120 °C on request

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

138
BIS C Industrial RFID System
Data carriers read/write

52×32×11 mm 25×25 mm Ø 60×21 mm Ø 22×21 mm Ø 22×21 mm


PBT PA 66 (fiberglass reinforced) POM Steel, coated Steel, coated
28 g 9g 85 g 18 g 18 g

70 kHz LF
BIS C Industrial
RFID System
BIS000F BIS0020 BIS001Z BIS00J2 BIS00J4 Range of
BIS C-108-05/L-SA2 BIS C-134-05/L-H120 BIS C-133-05/L BIS C-140-05/L-M8 BIS C-140-05/L-M6 applications
BIS000J BIS0021 BIS00J1 BIS00J3 Read/write
distances
BIS C-108-11/L-SA2 BIS C-134-11/L BIS C-133-11/L BIS C-140-11/L-M8 BIS C-140-11/L-M6 overview
–30...+70 °C –30...+70 °C –30...+70 °C –30...+70 °C –30...+70 °C Data carriers
read/write
–30...+85 °C* –30...+85 °C* –30...+85 °C –30...+85 °C –30...+85 °C
Read/write
IP 68 IP 68 IP 68 IP 68/x9K IP 68/x9K heads
use in vacuum use in vacuum use in vacuum use in vacuum use in vacuum Data
couplers
8-bit
processor
for read-only
mode
3 mm 3 mm 3 mm
Processors
Standard
6 mm 6 mm 4.5 mm 4.5 mm handheld
3 mm 3 mm 3 mm Read/write
heads
4 mm 11 mm 10 mm 10 mm 10 mm 7 mm 7 mm for handy
10 mm 16 mm 16 mm 15 mm 15 mm programmers
6 mm Handy
programmer
12 mm
Read/write
4 mm 11 mm 10 mm 10 mm 10 mm 7 mm 7 mm gun
4 mm 11 mm 10 mm 10 mm 10 mm 7 mm 7 mm Access
protection
4 mm 5 mm 5 mm
12 mm 12 mm 12 mm 12 mm

Sensing Sensing Sensing Sensing Sensing


face face face face face

■ www.balluff.com 139
BIS C Industrial RFID System
Read/write heads
Tool ID

Dimensions Ø 14.5 mm M16×1


6 1
Housing material Brass, coated Brass, coated
1 m cable Ordering code BIS00P5 BIS00PC
Part number BIS C-300-PU1-01 BIS C-306-PU1-01
5 m cable Ordering code BIS005Z BIS006F
Part number BIS C-300-PU1-05 BIS C-306-PU1-05
10 m cable Ordering code BIS00P6 BIS00PE
Part number BIS C-300-PU1-10 BIS C-306-PU1-10
Mounting
Operating temperature 0...+70 °C 0...+70 °C
Storage temperature –20...+85 °C –20...+85 °C
Degree of protection per IEC 60529 IP 67 IP 67
Connection to Processor Processor
Connection cable Cable included Cable included
BIS C-121-04/L-SA1

BIS C-130-05/L-SA1

BIS C-140-_ _/L-M_


see data carriers

see data carriers

see data carriers


BIS C-134-_ _-L

BIS C-191-_ _/L


BIS C-100-05/A

BIS C-103-05/A

BIS C-105-05/A

BIS C-121-04/L

BIS C-122-04/L

BIS C-130-05/L

BIS C-130-05/L
BIS000W

BIS001H
BIS001E

BIS001E
BIS000T
BIS0002

BIS0004

BIS0009

BIS0011

Appropriate data carrier


Mounting
Write distance in mm 0...4 0...3.5 0...3.5 0...2 0...1.2 0...2.5 0...4 0...3 0...4 0...4 0...3.5 0...3
Read distance in mm 0...4 0...3.5 0...3.5 0...2 0...1.2 0...2.5 0...4 0...3 0...4 0...4 0...3.5 0...3
Offset in mm at distance 0.7 mm ±2
1 mm ±3 ±3 ±3 ±2 ±2.5 ±3.5 ±4 ±5 ±5 ±4 ±3.5
3 mm ±2 ±2 ±2 ±3 ±4 ±4 ±3 ±2

For dynamic mode information pay


attention to Basic Information chapter. Sensing Sensing
face face
Caution!
At 10 m cable length, read/write
distance is reduced by 10 %

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

Description Handle
Use For read/write head
BIS C-300-_ _
Ordering code BAM012A
Part number BIS C-300-HG1

See accessories section for details.

140
BIS C Industrial RFID System
Read/write heads

33×61.5×38.5 mm
Aluminum, coated and PA 66

BIS00PA 70 kHz LF
BIS C-302-PU1-05
BIS C Industrial
BIS00P9 RFID System
BIS C-302-PU1-10 Range of
applications
0...+70 °C Read/write
distances
–20...+85 °C overview
IP 67 Data carriers
read/write
Processor
Read/write
Cable included heads
Data
couplers
BIS C-130-05/L-DB-002

8-bit
BIS C-121-04/L-SA1

BIS C-130-05/L-SA1

processor
see data carriers

for read-only
BIS C-191-_ _/L

mode
BIS C-100-05/A

BIS C-103-05/A

BIS C-105-05/A

BIS C-121-04/L

BIS C-122-04/L

BIS C-130-05/L

Processors
Standard
BIS000W

BIS001H
BIS001E
BIS000T
BIS0002

BIS0004

BIS0009

BIS0011

BIS0031

handheld
Read/write
heads
for handy
programmers
Handy
0...4 0...3 0...3 0...1.5 0...0.7 0...2 0...3.5 0...4 0...4 0...3 programmer
0...4 0...3 0...3 0...1.5 0...0.7 0...2 0...3.5 0...4 0...4 0...3 Read/write
gun
±1
Access
±3 ±3 ±3 ±1.5 ±2 ±3 ±5 ±5 ±4 protection
±2 ±1,5 ±1.5 ±2 ±3 ±3 ±2

Sensing
face Example:
BIS C-300-_ _

BIS C-650 BIS C-621-_ _ _-050-_ _

Cables on read/write heads must


not be shortened, since functionality
can then no longer be ensured.

■ www.balluff.com 141
BIS C Industrial RFID System
Read/write heads
Palletizing,
Logistics, Handling

Dimensions 50×25×10 mm
Housing material ABS (fiberglass reinforced)
1 m cable Ordering code BIS0066
Part number BIS C-305-PU1-01
5 m cable Ordering code BIS0067
Part number BIS C-305-PU1-05
10 m cable Ordering code BIS0068
Part number BIS C-305-PU1-10
Mounting
Operating temperature 0...+70 °C
Storage temperature –20...+85 °C
Degree of protection per IEC 60529 IP 67
Connection to Processor
Connection cable Cable included
BIS C-108-_ _/L-SA2

BIS C-121-04/L-SA1

BIS C-130-05/L-SA1

BIS C-140-_ _/L-M_


see data carriers

see data carriers

see data carriers


BIS C-108-_ _/L
BIS C-100-05/A

BIS C-103-05/A

BIS C-105-05/A

BIS C-117-05/A

BIS C-117-05/A
BIS C-117-05/L

BIS C-121-04/L

BIS C-122-04/L

BIS C-128-05/L

BIS C-130-05/L

BIS C-134-11/L
BIS000W
BIS000M

BIS000M
BIS000N

BIS001H
BIS001E
BIS000T
BIS0002

BIS0004

BIS0009

BIS0011

BIS0019

BIS0021
Appropriate data carrier
Mounting
Write distance in mm 0...4 0...5 0...5 0...6 0...6 1...8 0...7 0...2 0...1.2 0...2.5 0...10 0...6 0...7 0...7 0...6 0...4.5
Read distance in mm 0...4 0...5 0...5 0...6 0...6 1...8 0...7 0...2 0...1.2 0...2.5 0...10 0...6 0...7 0...7 0...6 0...4.5
Offset in mm at distance 0.7 mm ±2
1 mm ±3 ±4 ±4 ±8 ±8 ±5 ±8,5 ±2 ±3 ±6 ±8 ±5 ±5 ±5 ±4.5
3 mm ±2 ±3 ±3 ±7 ±7 ±4 ±7,5 ±2 ±6 ±7 ±5 ±5 ±5 ±3.5
5 mm ±5 ±5 ±3 ±6 ±6 ±5 ±4 ±4 ±4
7 mm ±2 ±4 ±5 ±2 ±2
10 mm ±3

For dynamic mode information pay Sensing


attention to Basic Information chapter. face

Caution!
At 10 m cable length, read/write
distance is reduced by 10 %

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

Data coupler BIS C-380-...


for data transmission between data carriers BIS C-1_ _ and read/write
head BIS C-3_ _ via a contactless extension see page 154/155.

142
BIS C Industrial RFID System
Read/write heads

M18×11 M30×1.5
0 15
PBT PVDF
BIS0077
BIS C-319-PU1-01
BIS0078 BIS007Y 70 kHz LF
BIS C-319-PU1-05 BIS C-326-PU1-05
BIS C Industrial
BIS0079 BIS007Z RFID System
BIS C-319-PU1-10 BIS C-326-PU1-10 Range of
applications
0...+70 °C 0...+70 °C Read/write
distances
–20...+85 °C –20...+85 °C overview
IP 67 IP 67 Data carriers
read/write
Processor Processor
Read/write
Cable included Cable included heads
Data
couplers
8-bit
BIS C-130-05/L-SA1

BIS C-130-05/L-SA1
processor
see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers


for read-only
BIS C-108-_ _/L

BIS C-191-_ _/L

BIS C-128-_ _/L

BIS C-128-_ _/L

BIS C-130-_ _/L

BIS C-133-_ _/L

BIS C-190-_ _/L


BIS C-117-05/L

BIS C-130-05/L

BIS C-134-11/L

BIS C-117-05/L

BIS C-134-11/L
mode
Processors
Standard
BIS000N

BIS001H

BIS000N

BIS001H
BIS001E

BIS0021

BIS0021
handheld
Read/write
heads
for handy
programmers
Handy
0...14 0...15 0...13 0...13 0...12 0...11 0...18 0...15 0...12.5 0...13 0...13 0...12 0...12 0...18 programmer
0...14 0...15 0...13 0...13 0...12 0...11 0...18 0...15 0...12.5 0...13 0...13 0...12 0...12 0...18 Read/write
gun
Access
±12 ±13 ±9 ±9 ±9 ±9 ±15 ±14 ±13 ±12 ±12 ±14 0...12 ±17 protection
±12 ±12 ±9 ±9 ±9 ±9 ±15 ±14 ±12 ±12 ±12 ±14 0...12 ±17
±11 ±12 ±9 ±9 ±9 ±9 ±15 ±14 ±12 ±10 ±10 ±14 ±10 ±17
±11 ±11 ±8.5 ±8.5 ±8.5 ±8 ±14 ±14 ±11 ±10 ±10 ±8.5 ±10 ±16
±9 ±10 ±7.5 ±7.5 ±7 ±11 ±8.5 ±8 ±14

Sensing Sensing
face face

Example: BIS C-319-_ _

Cables on read/write heads must


not be shortened, since functionality BIS C-650 BIS C-621-_ _ _-050-_ _
can then no longer be ensured.

■ www.balluff.com 143
BIS C Industrial RFID System
Read/write heads

Dimensions 80×80×40 mm
Housing material PBT
1 m cable Ordering code BIS00PK
Part number BIS C-315-PU1-01
5 m cable Ordering code BIS00PL
Part number BIS C-315-PU1-05
10 m cable Ordering code BIS00PM
Part number BIS C-315-PU1-10
Mounting
Operating temperature 0...+70 °C
Storage temperature –20...+85 °C
Degree of protection per IEC 60529 IP 67
Connection to Processor
Connection cable Cable included
BIS C-108-_ _/L-SA2
see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers


BIS C-104-_ _/A

BIS C-108-_ _/L

BIS C-128-_ _/L

BIS C-133-_ _/L

BIS C-190-_ _/L


BIS C-117-05/A

BIS C-117-05/L

BIS C-127-05/L

BIS C-130-05/L

BIS C-134-11/L
BIS000M

BIS000N

BIS001E
BIS0017

BIS0021

Appropriate data carrier


Mounting
Write distance in mm 1...13 2...16 2...16 0...15 0...18 10...30 0...18 0...18 0...15 0...16 0...20
Read distance in mm 1...13 2...16 2...16 0...15 0...18 10...30 0...18 0...18 0...15 0...16 0...20
Offset in mm at distance 0.7 mm
1 mm ±15 ±15 ±15 ±17 ±17 ±16 ±17 ±16 ±18
3 mm ±14 ±14 ±15 ±15 ±17 ±17 ±16 ±15 ±16 ±18
5 mm ±11 ±12 ±12 ±14 ±17 ±17 ±16 ±15 ±16 ±18
7 mm ±10 ±11 ±10 ±12 ±15 ±15 ±14 ±14 ±14 ±18
10 mm ±8 ±8 ±8 ±12 ±15 ±30 ±15 ±14 ±14 ±12 ±18
15 mm ±14 ±27 ±14 ±11 ±16
20 mm ±20

For dynamic mode information pay


attention to Basic Information chapter.

Caution!
At 10 m cable length, read/write
distance is reduced by 10 %

Mounting:

flush in steel

non-flush on steel
Sensing
non-metal
face

Antenna type:

rod

round

144
BIS C Industrial RFID System
Read/write heads

M30×1.5
15
Brass, coated
BIS00PF
BIS C-310-PU1-01
BIS00PH 70 kHz LF
BIS C-310-PU1-05
BIS C Industrial
BIS00PJ RFID System
BIS C-310-PU1-10 Range of
applications
0...+70 °C Read/write
distances
–20...+85 °C overview
IP 67 Data carriers
read/write
Processor
Read/write
Cable included heads
Data
couplers
8-bit
BIS C-108-_ _/L-SA2

BIS C-130-05/L-SA1

BIS C-140-_ _/L-M_


processor
see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

for read-only
BIS C-104-_ _/A

BIS C-104-_ _/A

BIS C-108-_ _/L

BIS C-128-_ _/L

BIS C-128-_ _/L

BIS C-133-_ _/L

BIS C-190-_ _/L

BIS C-191-_ _/L


BIS C-117-05/A

BIS C-117-05/L

BIS C-130-05/L

BIS C-134-11/L

mode
Processors
Standard
BIS000M

BIS000N

BIS001H
BIS001E

BIS0021

handheld
Read/write
heads
for handy
programmers
Handy
1...11 0...12 0...12 0...11 1...12 0...13 0...8 0...13 0...11 0...8 0...10 0...10 0...11 0...10 0...7 programmer
1...11 0...12 0...12 0...11 1...12 0...13 0...8 0...13 0...11 0...8 0...10 0...10 0...11 0...10 0...7 Read/write
gun
Access
±7.5 ±7.5 ±10 ±10 ±7.5 ±11 ±8 ±10 ±9 ±6.5 ±10 ±9 ±10 ±8 ±5.5 protection
±7 ±7 ±9 ±9 ±7.5 ±10 ±7 ±10 ±8 ±6 ±9 ±8 ±9 ±7.5 ±5
±7 ±7 ±9 ±8.5 ±7 ±10 ±6.5 ±9 ±7 ±5.5 ±9 ±7 ±9 ±7 ±4
±7 ±7 ±8.5 ±7.5 ±6.5 ±9.5 ±5.5 ±9 ±5 ±7 ±4 ±8 ±6.5
±6.5

Sensing
face

Example:
BIS C-319-_ _

Cables on read/write heads must


BIS C-650 BIS C-621-_ _ _-050-_ _
not be shortened, since functionality
can then no longer be ensured.

■ www.balluff.com 145
BIS C Industrial RFID System
Read/write heads

Dimensions M18×1
8 1 M18×1
Housing material PBT Stainless Steel
For 1 m cable Ordering code BIS007P
Part number BIS C-319/01-S4 BIS C-325/01-S4
For 5 m cable Ordering code BIS007A BIS007R
Part number BIS C-319/05-S4 BIS C-325/05-S4
For 10 m cable Ordering code BIS007C BIS007T
Part number BIS C-319/10-S4 BIS C-325/10-S4
Mounting
Operating temperature 0...+70 °C 0...+70 °C
Storage temperature –20...+85 °C –20...+85 °C
Degree of protection per IEC 60529 IP 67 IP 67
Connection to Processor Processor
Connection cable See page 282 for cable options See page 282 for cable options
BIS C-130-05/L-SA1

BIS C-121-04/L-SA1

BIS C-130-05/L-SA1

BIS C-140-_ _/L-M_


see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers


BIS C-108-_ _/L

BIS C-134-_ _/L

BIS C-191-_ _/L

BIS C-122-_ _/L

BIS C-191-_ _/L


BIS C-100-05/A
BIS C-117-05/L

BIS C-130-05/L

BIS C-130-05/L

BIS C-134-_ _L
BIS000W
BIS000N

BIS001H

BIS001H
BIS001E

BIS001E
BIS0002

Appropriate data carrier


Mounting
Write distance in mm 0...14 0...15 0...13 0...13 0...12 0...11 0...4 0...1.7 0...2.5 0...4 0...3 0...4 0...3 0...5
Read distance in mm 0...14 0...15 0...13 0...13 0...12 0...11 0...4 0...1.7 0...2.5 0...4 0...3 0...4 0...3.5 0...5
Offset in mm at distance 0.7 mm ±2
1 mm ±12 ±13 ±9 ±9 ±9 ±9 ±3.5 ±2 ±2.5 ±4 ±4 ±4 ±4 ±3
3 mm ±12 ±12 ±9 ±9 ±9 ±9 ±3 ±2 ±2 ±2 ±3 ±3
5 mm ±11 ±12 ±9 ±9 ±9 ±9 ±2
7 mm ±11 ±11 ±8.5 ±8.5 ±8 ±8
10 mm ±9 ±10 ±7.5 ±7.5 ±6

For dynamic mode information pay Sensing Sensing


attention to Basic Information chapter. face face

Caution!
At 10 m cable length, read/write
distance is reduced by 10 %

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

146
BIS C Industrial RFID System
Read/write heads

M30×1.515
Stainless Steel
BIS007J
BIS C-323/01-S4
BIS007K 70 kHz LF
BIS C-323/05-S4
BIS C Industrial
BIS007L RFID System
BIS C-323/10-S4 Range of
applications
–20...+70 °C Read/write
distances
–20...+85 °C overview
IP 67 Data carriers
read/write
Processor
Read/write
See page 282 for cable options heads
Data
couplers
8-bit
BIS C-108-_ _/L-SA2

BIS C-130-05/L-SA1

BIS C-140-_ _/L-M_


processor
see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

for read-only
BIS C-104-_ _/A

BIS C-104-_ _/A

BIS C-108-_ _/L

BIS C-128-_ _/L

BIS C-128-_ _/L

BIS C-133-_ _/L

BIS C-134-_ _/L

BIS C-190-_ _/L

BIS C-191-_ _/L

mode
BIS C-117-05/A

BIS C-117-05/L

BIS C-130-05/L

Processors
Standard
BIS000M

BIS000N

BIS001H
BIS001E

handheld
Read/write
heads
for handy
programmers
Handy
1...11 0...12 0...12 0...11 1...12 0...13 0...8 0...13 0...11 0...8 0...10 0...10 0...11 0...10 0...7 programmer
1...11 0...12 0...12 0...11 1...12 0...13 0...8 0...13 0...11 0...8 0...10 0...10 0...11 0...10 0...7 Read/write
gun
Access
±7.5 ±7.5 ±10 ±10 ±7.5 ±11 ±8 ±10 ±9 ±6,5 ±10 ±9 ±10 ±8 ±5.5 protection
±7 ±7 ±9 ±9 ±7.5 ±10 ±7 ±10 ±8 ±6 ±9 ±8 ±9 ±7,5 ±5
±7 ±7 ±9 ±8.5 ±7 ±10 ±6 ±9 ±7 ±5.5 ±9 ±7 ±9 ±7 ±4
±7 ±7 ±8.5 ±7.5 ±6.5 ±9.5 ±5.5 ±9 ±5 ±7 ±4 ±8 ±6.5
±6.5

Sensing
face

Example:
BIS C-325 BIS C-505-PU-_ _

Cables on read/write heads must


not be shortened, since functionality
can then no longer be ensured. BIS C-650 BIS C-621-_ _ _-050-_ _

■ www.balluff.com 147
BIS C Industrial RFID System
Read/write heads

Dimensions 80×80×40
×80×40 mm
Housing material PBT
For 5 m cable Ordering code BIS006Y
Part number BIS C-315/05-S4
For 10 m cable Ordering code BIS006Z
Part number BIS C-315/10-S4
Mounting
Operating temperature 0...+70 °C
Storage temperature –20...+85 °C
Degree of protection per IEC 60529 IP 67
Connection to Processor
Connection cable See page 282 for cable options
BIS C-108-_ _/L-SA2
see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers


BIS C-104-_ _/A

BIS C-108-_ _/L

BIS C-128-_ _/L

BIS C-133-_ _/L

BIS C-190-_ _/L


BIS C-117-05/A

BIS C-117-05/L

BIS C-127-05/L

BIS C-130-05/L

BIS C-134-11/L
BIS000M

BIS000N

BIS001E
BIS0017

BIS0021

Appropriate data carrier


Mounting
Write distance in mm 1...13 2...16 2...16 0...15 0...20 10...30 0...18 0...18 0...15 0...16 0...20
Read distance in mm 1...13 2...16 2...16 0...15 0...20 10...30 0...18 0...18 0...15 0...16 0...20
Offset in mm at distance 1 mm ±15 ±15 ±17 ±17 ±16 ±17 ±16 ±18
3 mm ±14 ±14 ±15 ±15 ±17 ±17 ±16 ±15 ±16 ±18
5 mm ±11 ±12 ±12 ±14 ±17 ±17 ±16 ±15 ±16 ±18
7 mm ±10 ±11 ±10 ±12 ±15 ±15 ±14 ±14 ±14 ±18
10 mm ±8 ±8 ±8 ±12 ±15 ±30 ±15 ±14 ±14 ±12 ±18
15 mm ±14 ±27 ±14 ±11 ±16
20 mm ±20

For dynamic mode information pay


attention to Basic Information chapter.

Caution!
At 10 m cable length, read/write
distance is reduced by 10 %

Mounting:

flush in steel

Sensing
face
non-metal

Antenna type:

rod

round

148
BIS C Industrial RFID System
Read/write heads

40×40×73 mm
PBT and cast zinc
BIS007M
BIS C-324/05-S4
BIS007N 70 kHz LF
BIS C-324/10-S4
BIS C Industrial
RFID System
0...+70 °C Range of
–20...+85 °C applications
IP 67 Read/write
distances
Processor overview
See page 282 for cable options Data carriers
read/write
Read/write
heads
BIS C-108-_ _/L-SA2

BIS C-130-05/L-SA1

Data

BIS C-140-_ _/L-M_


see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers

see data carriers couplers


BIS C-104-_ _/A

BIS C-104-_ _/A

BIS C-108-_ _/L

BIS C-128-_ _/L

BIS C-128-_ _/L

BIS C-133-_ _/L

BIS C-190-_ _/L

BIS C-191-_ _/L


BIS C-117-05/A

BIS C-117-05/L

BIS C-130-05/L

BIS C-134-11/L

8-bit
processor
for read-only
BIS000M

mode
BIS000N

BIS001H
BIS001E

BIS0021

Processors
Standard
handheld
Read/write
heads
1...11 0...12 0...12 0...11 0...12 0...13 0...8 0...13 0...11 0...8 0...10 0...10 0...11 0...10 0...7 for handy
programmers
1...11 0...12 0...12 0...11 0...12 0...13 0...8 0...13 0...11 0...8 0...10 0...10 0...11 0...10 0...7
Handy
±7.5 ±7.5 ±10 ±10 ±7.5 ±11 ±8 ±10 ±9 ±6.5 ±10 ±9 ±10 ±8 ±5.5 programmer
±7 ±7 ±9 ±9 ±7.5 ±10 ±7 ±10 ±8 ±6 ±9 ±8 ±9 ±7.5 ±5.5 Read/write
±7 ±7 ±9 ±8.5 ±7 ±10 ±6.5 ±9 ±7 ±5.5 ±9 ±7 ±9 ±7 ±4 gun
Access
±7 ±7 ±8.5 ±7.5 ±6.5 ±9.5 ±5.5 ±9 ±5 ±7 ±4 ±8 ±6.5 protection
±6.5

Sensing
face

Example:
BIS C-324 BIS C-505-PU-_ _

BIS C-621-_ _ _-050-_ _

Cables on read/write heads must


not be shortened, since functionality BIS C-650
can then no longer be ensured.

■ www.balluff.com 149
BIS C Industrial RFID System Long Distances
Read/write heads

Dimensions 88×43×20
3×20 mm
Housing material POM
For 1 m cable Ordering code
Part number BIS C-327-01
For 5 m cable Ordering code BIS0080
Part number BIS C-327-05
For 10 m cable Ordering code
Part number BIS C-327-10
Mounting
Operating temperature 0...+70 °C
Storage temperature –20...+85 °C
Degree of protection per IEC 60529 IP 67
Connection to Processor
Connection cable Cable included

BIS C-108-05/L

BIS C-128-11/L

BIS C-190-32/L
BIS000C

BIS001C

BIS002N
Appropriate data carrier
BIS C-318 Write distance in mm 0...8 0...8 0...8
Read distance in mm 0...8 0...8 0...8
Offset in mm at distance 1 mm ±6 ±6 ±6
2 mm ±6 ±6 ±6
3 mm ±6 ±6 ±6
4 mm ±5 ±5 ±5
5 mm ±5 ±5 ±5
6 mm ±4 ±4 ±4
10 mm
20 mm

For dynamic mode information pay attention to Basic Information chapter.

Caution!
At 10 m cable length, read/write distance is reduced by 10 %

Mounting:

flush in steel

non-flush on steel Sensing Write/read


face axis
non-metal

Antenna type:

rod

Example: round

BIS C-650

Cables on read/write heads must


BIS C-621-_ _ _-050_ _ not be shortened, since functionality
can then no longer be ensured.

150
BIS C Industrial RFID System
Read/write heads

55×30×20 mm 186×48×30
8×30 mm 170×
170×80×50 mm
POM PA 66 POM

BIS C-328/01-S49
BIS0081 BIS0075 BIS00PN 70 kHz LF
BIS C-328/05-S49 BIS C-318-PU1-05 BIS C-351-PU1-05
BIS C Industrial
BIS00L4 BIS00PP RFID System
BIS C-328/10-S49 BIS C-318-PU1-10 BIS C-351-PU1-10 Range of
applications
0...+70 °C 0...+70 °C –20...+80 °C Read/write
distances
–20...+85 °C –20...+85 °C –20...+85 °C overview
IP 67 IP 67 IP 67 Data carriers
read/write
Processor Processor Processor
Read/write
See page 284 for cable options Cable included Cable included heads
Data
couplers
BIS C-108-_ _/L-SA2

8-bit
see data carriers

see data carriers

see data carriers

see data carriers

processor
BIS C-108-_ _/L

BIS C-128-_ _/L

BIS C-190-_ _/L

BIS C-150-05/A

BIS C-150-11/A

BIS C-150-32/A
BIS C-122-04/L

BIS C-122-11/L

BIS C-117-05/L

BIS C-127-05/L

for read-only
mode
Processors
BIS000N

BIS002A

BIS002E
BIS0011

BIS0015

BIS0017

BIS0028

Standard
handheld
Read/write
heads
0...3 0...3 0...6 0...7 0...7 10...35 0...7.5 8 0...45 0...45 0...45 for handy
programmers
0...3 0...3 0...6 0...7 0...7 10...35 0...7.5 8 0...45 0...45 0...45
Handy
±2.5 ±2.5 ±8.5 ±9.5 9.5 ±11 ±11 ±15 ±15 ±15 programmer
±2.5 ±2.5 ±8.5 ±9.5 9.5 ±11 ±11 ±15 ±15 ±15 Read/write
gun
±2.5 ±2.5 ±8.5 ±9.5 9.5 ±11 ±11 ±15 ±15 ±15
Access
±8.5 ±9.5 9.5 ±8 ±10 ±15 ±15 ±15 protection
±5.5 ±8.5 ±8.5 ±8 ±10 ±15 ±15 ±15
±8.5 ±8.5 ±15 ±15 ±15
±25 ±15 ±15 ±15
±20 ±15 ±15 ±15

Sensing
face

Write/read
axis
Write/read
axis Write/read
axis

■ www.balluff.com 151
BIS C Industrial RFID System Long Distances
Read/write heads

Dimensions
Housing material
Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Example: Connection to
BIS C-350
Connection cable

Appropriate data carrier


Write distance in mm
Read distance in mm
Offset in mm at distance 10 mm
15 mm
20 mm
BIS C-355
35 mm
42 mm
60 mm

For dynamic mode information pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

BIS C-516 non-metal

Antenna type:

rod

round

BIS C-520

BIS C-670 BIS C-654

152
BIS C Industrial RFID System
Read/write heads

dual antenna for


increased traverse speed

240×120×60 mm 240×120×60 mm
PC PC
BIS0086 BIS008E
BIS C-350-00.3 BIS C-355/05-S92
70 kHz LF
0...+40 °C 0...+70 °C
BIS C Industrial
–20...+85 °C –20...+85 °C RFID System
IP 67 IP 65 Range of
Processor only with connection cable Processor only with connection cable applications
BIS C-516-PU-_ _ (page 286, please order separately) BIS C-520-PVC-05 (page 287, please order separately) Read/write
distances
0.3 m cable PUR with Burndy® connector, 8-pin overview
Data carriers
read/write
Read/write
heads
BIS C-150-05/A

BIS C-150-11/A

BIS C-150-32/A

BIS C-150-05/A

BIS C-150-11/A

BIS C-150-32/A
Data
couplers
8-bit
BIS002A

BIS002A
BIS002E

BIS002E
BIS0028

BIS0028

processor
for read-only
mode
Processors
90 90 90 0...35 0...35 0...35 Standard
100 100 100 0...40 0...40 0...40 handheld
Read/write
±30 ±30 ±30 ±15 ±15 ±15 heads
±30 ±30 ±30 ±15 ±15 ±15 for handy
programmers
±30 ±30 ±30 ±15 ±15 ±15
Handy
±30 ±30 ±30 ±15 ±15 ±15 programmer
±30 ±30 ±30 ±5 ±5 ±5 Read/write
±30 ±30 ±30 gun
Access
protection

4× 4×
mounting mounting
screw M4 screw M4
DIN 912 DIN 912
Write/read Write/read
axis axis

■ www.balluff.com 153
BIS C Industrial RFID System
Data couplers

Dimensions M16×1 and M16×1


Housing material Brass, coated
1 m cable Ordering code BIS00JJ
Part number BIS C-380-06/06-01
2 m cable Ordering code BIS00LU
Part number BIS C-380-06/06-02
5 m cable Ordering code BIS00N9
Part number BIS C-380-06/06-05
Read head connection Contactless connection
Operating temperature 0...+70 °C
Data
couplers Storage temperature –20...+85 °C
Degree of protection per IEC 60529 IP 67
Adapter plate
Data carriers
Workpiece

Clamping device

BIS C-100-05/A

BIS C-103-05/A

BIS C-105-05/A

BIS C-121-04/L

BIS C-122-04/L
Fixture
rotates

BIS000T
BIS0002

BIS0004

BIS0009

BIS0011
Machine bed

Appropriate data carrier


Mounting
Appropriate read/write head BIS C-300
BIS C-302
Read/ Processor BIS C-305
write head BIS C-306
Data couplers are used in applications where Max. read/write distance see diagram
a dual mechanical interface is mandatory.
Mounting:

Data carrier
flush in steel Sensing Sensing
face face
Distance A non-flush on steel

non-metal

Antenna type:

Data coupler rod

round

Distance A Example:
mm Distance A 0.5 mm
Distance B 1.5 mm
Distance B 2 or
Distance A 1.3 mm
Distance B 0.7 mm
1.5
Read/write head
1

0.5

0 Distance B
0 0.5 1 1.5 2 mm

154
BIS C Industrial RFID System
Data couplers

50×25×10 mm and M16×1 M16×1 and M30×1.5 M30×1.5 and M30×1.5


ABS (fiberglass reinforced) and brass, coated Brass, coated Brass, coated
BIS00JP
BIS C-380-10/10-01
BIS00JE BIS00JM 70 kHz LF
BIS C-380-05/06-02 BIS C-380-06/10-02
BIS C Industrial
BIS00N8 BIS00JN BIS00JR RFID System
BIS C-380-05/06-05 BIS C-380-06/10-05 BIS C-380-10/10-05 Range of
Contactless connection Contactless connection Contactless connection applications
0...+70 °C 0...+70 °C 0...+70 °C Read/write
distances
–20...+85 °C –20...+85 °C –20...+85 °C overview
IP 67 IP 67 IP 67 Data carriers
read/write
Read/write
heads

see data carriers

see data carriers

see data carriers


Data

BIS C-104-_ _/A

BIS C-108-_ _/L

BIS C-128-_ _/L


BIS C-100-05/A

BIS C-103-05/A

BIS C-105-05/A

BIS C-100-05/A

BIS C-103-05/A

BIS C-105-05/A
BIS C-121-04/L

BIS C-122-04/L

BIS C-121-04/L

BIS C-122-04/L

BIS C-117-05/L

BIS C-130-05/L
couplers
8-bit
processor

BIS000N

BIS001E
BIS000T

BIS000T
BIS0002

BIS0004

BIS0009

BIS0011

BIS0002

BIS0004

BIS0009

BIS0011

for read-only
mode
Processors
Standard
handheld
Read/write
BIS C-300 BIS C-310 BIS C-310 heads
BIS C-302 for handy
programmers
BIS C-305
Handy
BIS C-306 programmer
see diagram see diagram see diagram Read/write
gun
Access
protection
Sensing Sensing Sensing Sensing Sensing
Sensing face face face face face
face

Distance A Distance A Distance A


mm mm mm

2 2 10

1.5 1.5 7.5

1 1 5

0.5 0.5 2.5

0 Distance B 0
0 Distance B Distance B
0 0.5 1 1.5 2 mm 0 2 4 6 8 mm 0 2 4 6 8 mm

Type C-306 Type C-310

Read/write head

Data coupler
BIS C-380-06/10-_ _
Data carrier

■ www.balluff.com 155
BIS C Industrial RFID System
8-bit processor for read-only mode
I/O Interface

Dimensions M30×1 M30×1 M30×1


Housing material Brass, coated Brass, coated Brass, coated
Description/interface 8-bit parallel 8×8-bit parallel 2×8-bit parallel dynamic*
5 m cable Ordering code BIS00H6 BIS00HC BIS00HH
Part number BIS C-60R-001-08P-PU-05 BIS C-60R-002-08P-PU-05 BIS C-60R-003-08P-PU-05
10 m cable Ordering code BIS00H7 BIS00HE BIS00HJ
Part number BIS C-60R-001-08P-PU-10 BIS C-60R-002-08P-PU-10 BIS C-60R-003-08P-PU-10
20 m cable Ordering code BIS00H8 BIS00TC
Part number BIS C-60R-001-08P-PU-20 BIS C-60R-002-08P-PU-20 BIS C-60R-003-08P-PU-20
Mounting
Supply voltage 24 V DC +10/–20 %, incl. ripple 24 V DC +10/–20 %, incl. ripple 24 V DC +10/–20 %, incl. ripple
Current max. 300 mA without load max. 300 mA without load max. 300 mA without load
Output current per output max. 50 mA max. 50 mA max. 50 mA
Voltage drop ≤ 1.5 V ≤ 1.5 V ≤ 1.5 V
Leakage current ≤ 0.08 mA ≤ 0.08 mA ≤ 0.08 mA
Operating temperature 0...+50 °C 0...+50 °C 0...+50 °C
Degree of protection per IEC 60529 IP 67 IP 67 IP 67
Tightening torque 20 Nm 20 Nm 20 Nm
Conductor cross-sections 2× 0.5 mm² and 9× 0.18 mm² 2× 0.5 mm² and 9× 0.18 mm² 2× 0.5 mm² and 9× 0.18 mm²
LED function indicator Yes Yes Yes
BIS C-103-05/A

BIS C-103-05/A

BIS C-100-05/A

BIS C-100-05/A

BIS C-117-05/A

BIS C-104-11/A
BIS C-121-04/L

BIS C-121-04/L

BIS C-122-04/L

BIS C-130-05/L

BIS C-130-05/L

BIS C-128-05/L

BIS C-117-05/L

BIS C-108-05/L

BIS C-108-05/L
BIS000M

BIS000N

BIS000C

BIS000C
BIS001E

BIS001E
BIS000T

BIS000T

BIS0011

BIS0004

BIS0004

BIS0002

BIS0002

BIS0019

BIS0006
Appropriate data carrier
Mounting
Read distance in mm 0...3 1...5 1...5 0...4 1...5 0...5 1...8 0...5 1...6 3...12 1...8 1...8 1...8 1...8 0...6
Offset in mm at distance 1 mm ±2 ±3 ±3 ±4 ±2.5 ±3 ±4 ±2.5 ±3 ±5 ±7 ±7 ±4 ±7
3 mm ±2 ±3 ±3 ±2.5 ±2.5 ±3 ±5 ±3 ±3 ±7 ±5 ±7 ±7 ±4 ±7
5 mm ±3 ±3 ±2.5 ±3 ±5 ±3 ±3 ±6 ±5 ±7 ±7 ±4 ±6
7 mm ±5 ±5 ±5 ±6 ±6 ±4

* Dynamic mode only possible for BIS C-60R-003


Sensing
face
Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

156
BIS C Industrial RFID System
8-bit processor for read-only mode

40×40×149 mm
ABS
8-bit parallel
BIS00HL
BIS C-61R-001-08P-PU-05 70 kHz LF
BIS C Industrial
RFID System
Range of
applications
Read/write
distances
24 V DC +10/–20 % (incl. ripple) overview
max. 300 mA without load Data carriers
read/write
max. 50 mA
Read/write
≤ 1.5 V heads
≤ 0.08 mA Data
0...+50 °C couplers
8-bit
IP 67 processor
20 Nm for read-only
mode
2× 0.5 mm² and 9× 0.18 mm²
Processors
Yes
Standard
handheld
Read/write
heads
for handy
BIS C-103-05/A

BIS C-103-05/A

BIS C-100-05/A

BIS C-100-05/A

BIS C-117-05/A

BIS C-104-11/A
BIS C-121-04/L

BIS C-122-04/L

BIS C-121-04/L

BIS C-122-04/L

BIS C-130-05/L

BIS C-130-05/L

BIS C-128-05/L

BIS C-128-05/L

BIS C-117-05/L

BIS C-108-11/L

BIS C-108-11/L

programmers
Handy
programmer
BIS000M

BIS000N

BIS000H

BIS000H
BIS001E

BIS001E
BIS000T

BIS000T
BIS0011

BIS0011

BIS0004

BIS0004

BIS0002

BIS0002

BIS0019

BIS0019

BIS0006

Read/write
gun
Access
protection

0...2 0...2 1...4 1...4 0...3 1...4 0...4 1...7 0...4 1...5 0...3 3...7 1...7 1...7 1...4 0...5 1...7
±2 ±2 ±3 ±3 ±3 ±2.5 ±3 ±4 ±2.5 ±3 ±5 ±5 ±7 ±4 ±7 ±7
±3 ±3 ±2.5 ±3 ±5 ±3 ±3 ±7 ±5 ±7 ±4 ±6 ±7
±5 ±6 ±5 ±6 ±4 ±6

Sensing
face

The BIS C-60R-001-08P-_ _ read-only system is designed for


simple applications of the BIS C read/write system. It is supplied as
a read-only system and provides the 8 bits of information without
any additional components in parallel format. Three bytes per value
are always used starting at Address 0.

The remaining bytes on the data carrier can be used for other pur-
poses with the appropriate processors. For this function the bytes
on the data carrier (starting at Address 0) must be pre-programmed
before a read operation can take place.

To easily program the data carrier a processor with serial port and
Balluff 007 protocol are used. Programming is easy and fast using
the free BISCOMRW software downloadable from the Balluff web
site at www.balluff.com.

■ www.balluff.com 157
BIS C Industrial RFID System
Serial processors
Serial RS232

Description Processor
Housing material ABS
RS232, Ordering code BIS008U
Balluff dialog Part number BIS C-600-007-650-00-KL1
RS422/RS485, Ordering code BIS008W
4-wire, point-to-point, Balluff dialog Part number BIS C-600-007-650-02-KL1
Supply voltage, Ripple 24 V DC ±20 %, ≤ 10 %
Current ≤ 400 mA
Operating temperature 0...+60 °C
Storage temperature 0...+60 °C
Degree of protection per IEC 60529 IP 65
Read/write head ports 2× external
Control inputs 1× via opto-coupler, 24 V DC
Control outputs 4× via opto-coupler, 24 V DC
Connection for
Connection type Terminals 3× Pg 9

Accessories included Configuration software


Connection cable See page 282 for cable options

Adapter or antenna can be


rotated in 3 directions

The compact class BIS C-6_ _ with its reduced dimensions and
various interface options can be used wherever ambient conditions
require higher protection. The devices are ideal for IP 65 applications
involving media that is not aggressive to PS plastic. Small, compact,
flexible and economical. Read/write head can be rotated in
3 directions.

158
BIS C Industrial RFID System
Serial processors

Processor Processor Processor


ABS ABS Aluminum cast, coated
BIS0092 BIS00AZ
BIS C-600-007-670-00-KL1 BIS C-600-007-654-00-KL1 BIS C-620-007-050-00-ST2
BIS00KW 70 kHz LF
BIS C-620-007-050-02-ST2
BIS C Industrial
24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 % RFID System
≤ 400 mA ≤ 400 mA ≤ 400 mA Range of
0...+60 °C 0...+60 °C 0...+60 °C applications
0...+60 °C 0...+60 °C 0...+60 °C Read/write
distances
IP 65 IP 65 IP 65 overview
1× external 1× external/special 2× external Data carriers
read/write
1× via opto-coupler, 24 V DC 1× via opto-coupler, 24 V DC 1× M23 connector male, 9-pin
Read/write
4× via opto-coupler, 24 V DC 4× via opto-coupler, 24 V DC 1× M12 connector male, 5-pin heads
RS232/422/485 Data
Terminals 3× Pg 9 Terminals 3× Pg 9 Read/write heads BIS C-3_ _ couplers
8-bit
(Exception: BIS C-350) processor
Configuration software Configuration software Configuration software for read-only
mode
See page 286 for cable options See page 287 for cable options See page 282/289/305 for cable options
Processors
Standard
handheld
Read/write
heads
for handy
programmers
Handy
programmer
Read/write
gun
Access
protection

for read/write head C-350 for read/write head BIS C-355/05-S92

Processor unit BIS C-62_ enclosed in a robust metal housing is


suitable for applications requiring degree of protection IP 65. Flexible
interface versions and the option of connecting two read/write heads
to a single unit are ideal. The special housing provides effective
protection against environmental influences and aggressive media. 06Z9
BCC
Impacts do not affect the degree of protection.

00TA
BCC

■ www.balluff.com 159
BIS C Industrial RFID System
Parallel processors
Parallel

Advantages of the BIS C-6005 parallel version


The parallel interface is a read-only-interface. Writing is therefore not
possible in parallel mode. However, the processor unit can write a
single piece of bit information (OK/NOK, large/small, version 1/
version 2) to the data carrier. Bit information is transmitted in the
form of a separate output signal.

The compact class BIS C-6_ _ with its reduced dimensions and
various interface options can be used wherever ambient conditions
require higher protection. Small, compact, flexible and economical.
Description
Housing material
Parallel Ordering code
Part number
Supply voltage, Ripple
Current
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Read/write head ports
Control inputs
Control outputs
Connection type
Accessories included
Connection cable

Adapter or antenna can be


rotated in 3 directions

160
BIS C Industrial RFID System
Parallel processors

Processor
ABS
BIS00N7
BIS C-6005-027-650-05-ST4
24 V DC ±20 %, ≤ 10 % 70 kHz LF
≤ 400 mA
BIS C Industrial
0...+60 °C RFID System
0...+60 °C Range of
IP 54 applications
2× external Read/write
distances
4× via opto-coupler, 24 V DC overview
13× via opto-coupler, 24 V DC Data carriers
read/write
MIN Sub-D male, 25-pin
Read/write
Configuration software heads
See page 282/287 for cable options Data
couplers
8-bit
processor
for read-only
mode
Processors
Standard
handheld
Read/write
heads
for handy
programmers
Handy
programmer
Read/write
gun
Access
protection

■ www.balluff.com 161
BIS C Industrial RFID System
Profibus processors

The compact class


BIS C-600_ with its reduced
dimensions and various interface
options can be used wherever
ambient conditions require
higher protection. Small, com-
pact, flexible and economical.

Cost-effective identification –
operate two read/write heads
simultaneously Description Processor
■ Selectable division of the Housing material ABS
data width on the Profibus, Profibus with connector Ordering code BIS009A
from 4...128 bytes Part number BIS C-6002-019-650-03-ST11
■ Free assigning of the data Profibus memory optimization Ordering code BIS009M
width for each read/write head with connector Part number BIS C-6002-028-650-03-ST11
■ Optimum data speed, internal Profibus with PG fitting Ordering code BIS0099
cycle time is shorter than the Part number BIS C-6002-019-650-03-KL2
bus activation time Profibus memory optimization Ordering code BIS009L
■ Service friendly, all parameter with PG fitting Part number BIS C-6002-028-650-03-KL2
data are stored in an exchan- Supply voltage, Ripple 24 V DC ±20 %, ≤ 10 %
geable memory Current ≤ 400 mA
■ Bus address selectable with Operating temperature 0...+60 °C
switches Storage temperature 0...+60 °C
■ Compatible with BIS C-602 Degree of protection per IEC 60529 IP 65
device family Read/write head ports 2× external
■ Accepts all read/write heads Service interface RS232
■ Compatible with entire BIS C Control inputs 1× via opto-coupler, 24 V DC
system Control outputs 2× via opto-coupler, 24 V DC
Connection version ST11 1× M12 connector male, 5-pin, B-coded
1× M12 connector female, 5-pin, B-coded
1× M12 connector male, 5-pin
Connection type clamp terminals KL2 Terminals 1× Pg 9, Terminals 2× Pg 11
Accessories included Software GSD file
Connection cable See page 282/290/305 for cable options

Version KL2

Adapter or antenna can be


rotated in 3 directions

Recommended accessories
(please order separately)

Ordering code BAM0114


Part number BKS 12-CS-01
Threaded cover for M12 connector

162
BIS C Industrial RFID System
Profibus processors

Processor Processor Processor


ABS ABS ABS
BIS009F BIS009J
BIS C-6002-019-654-03-ST11 BIS C-6002-019-655-03-ST11
70 kHz LF
BIS C Industrial
BIS009K BIS009H RFID System
BIS C-6002-019-670-03-KL2 BIS C-6002-019-655-03-KL2 Range of
applications
Read/write
distances
24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 % overview
≤ 400 mA ≤ 400 mA ≤ 400 mA Data carriers
read/write
0...+60 °C 0...+60 °C 0...+60 °C
Read/write
0...+60 °C 0...+60 °C 0...+60 °C heads
IP 65 IP 65 IP 65 Data
1× external 1× external 4× external couplers
8-bit
RS232 RS232 RS232 processor
1× via opto-coupler, 24 V DC 1× via opto-coupler, 24 V DC 1× via opto-coupler, 24 V DC for read-only
mode
2× via opto-coupler, 24 V DC 2× via opto-coupler, 24 V DC 2× via opto-coupler, 24 V DC
Processors
1× M12 connector male, 5-pin, B-coded 1× M12 connector male, 5-pin, B-coded 1× M12 connector male, 5-pin, B-coded
Standard
1× M12 connector female, 5-pin, B-coded 1× M12 connector female, 5-pin, B-coded 1× M12 connector female, 5-pin, B-coded handheld
1× M12 connector male, 5-pin 1× M12 connector male, 5-pin 1× M12 connector male, 5-pin Read/write
heads
Terminals 1× Pg 9, Terminals 2× Pg 11 Terminals 1× Pg 9, Terminals 2× Pg 11 Terminals 1× Pg 9, Terminals 2× Pg 11 for handy
Software GSD file Software GSD file Software GSD file programmers
See page 286/290/305 for cable options See page 287/290/305 for cable options See page 282/290/305 for cable options Handy
programmer
Read/write
gun
Access
protection

Note: 2 read/write heads can


for read/write head BIS C-350 for read/write head BIS C-355/_ _-S92
be operated simultaneously

■ www.balluff.com 163
BIS C Industrial RFID System
Profibus processors

Cost-effective identification –
operate two read/write heads
simultaneously! In a robust metal
housing.

Description
Housing material
Profibus Ordering code
Part number
Profibus Ordering code
with memory optimized data carrier processing Part number
Supply voltage, Ripple
Current
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Read/write head ports
Service interface
Connection for

Connection type

Accessories included
Connection cable

Recommended accessories
(please order separately) Z9
C 06
BC

C
0T
C0
BC

Description Threaded cover Threaded cover


C
for M12 connector for M23 connector 0T
C0
Ordering code BAM0114 BAM012P BC

Part number BKS 12-CS-01 BKS 23-CS-00

164
BIS C Industrial RFID System
Profibus processors

Processor Processor
Aluminum cast, coated Aluminum cast, coated
BIS00AL BIS00AM
BIS C-6022-019-050-03-ST10 BIS C-6022-019-050-03-ST14
BIS00AP BIS00AR 70 kHz LF
BIS C-6022-028-050-03-ST10 BIS C-6022-028-050-03-ST14
BIS C Industrial
24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 % RFID System
≤ 400 mA ≤ 400 mA Range of
applications
0...+60 °C 0...+60 °C
Read/write
0...+60 °C 0...+60 °C distances
overview
IP 65 IP 65
Data carriers
2× external 2× external read/write
RS232 RS232 Read/write
heads
Read/write heads BIS C-3_ _ Read/write heads BIS C-3_ _
Data
Exception: BIS C-350/BIS C-355 Exception: BIS C-350/BIS C-355 couplers
2× M23 connector female, 12-pin (bus) 1× M12 connector male, 5-pin, B-coded (bus) 8-bit
1× M12 connector male, 5-pin (power) 1× M12 connector female, 5-pin, B-coded (bus) processor
for read-only
1× M12 connector male, 4-pin (service) 1× M12 connector male, 5-pin (power) mode
1× M12 connector male, 4-pin (service) Processors
Software GSD file Software GSD file Standard
handheld
See page 282/289/305 for cable options See page 282/290/305 for cable options Read/write
heads
for handy
programmers
Handy
programmer
Read/write
gun
Access
protection

9
06Z
BCC

5
071
BCC

14
C07
BC

■ www.balluff.com 165
BIS C Industrial RFID System
Devicenet processors

The devices are ideal for IP 65


and applications involving media
that is not aggressive to PS
plastic. Small, compact, flexible
and economical.

The compact class


BIS C-600_ with its reduced
dimensions and various interface
options can be used wherever
ambient conditions require hig- Description Processor
her protection. Housing material ABS
Devicenet Ordering code BIS009N
Cost-effective identification – Part number BIS C-6003-025-650-03-ST12
operate 2 read/write Supply voltage, Ripple 24 V DC ±20 %, ≤ 10 %
heads simultaneously Current ≤ 400 mA
■ Freely selectable buffer size Operating temperature 0...+60 °C
between 0 and 256 bytes Storage temperature 0...+60 °C
■ Service friendly, all parameter Degree of protection per IEC 60529 IP 65
data are stored in an exchan- Read/write head ports 2× external
geable memory Service interface RS232
■ Accepts all read/write heads Connection for Read/write heads BIS C-3_ _
■ Compatible with entire Exception: BIS C-350/BIS C-355
BIS C system Connection type 2× M12 connector male, 5-pin
1× M12 connector female, 5-pin
Accessories included Software EDS file
Connection cable See page 282/296/305 for cable options

Adapter or antenna can be


rotated in 3 directions

166
BIS C Industrial RFID System
Devicenet processors

Processor Processor Processor


ABS ABS ABS
BIS009T BIS009R
BIS C-6003-025-670-03-ST12 BIS C-6003-025-654-03-ST12 BIS C-6003-025-655-03-ST12
24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 % 70 kHz LF
≤ 400 mA ≤ 400 mA ≤ 400 mA
BIS C Industrial
0...+60 °C 0...+60 °C 0...+60 °C RFID System
0...+60 °C 0...+60 °C 0...+60 °C Range of
IP 65 IP 65 IP 65 applications
1× external 1× external 4× external Read/write
distances
RS232 RS232 RS232 overview
Read/write heads BIS C-3_ _ Read/write heads BIS C-3_ _ Read/write heads BIS C-3_ _ Data carriers
read/write
Exception: BIS C-350/BIS C-355 Exception: BIS C-350/BIS C-355 Exception: BIS C-350/BIS C-355
Read/write
2× M12 connector male, 5-pin 2× M12 connector male, 5-pin 2× M12 connector male, 5-pin heads
1× M12 connector female, 5-pin 1× M12 connector female, 5-pin 1× M12 connector female, 5-pin Data
Software EDS file Software EDS file Software EDS file couplers
8-bit
See page 286/296/305 for cable options See page 287/296/305 for cable options See page 282/296/305 for cable options processor
for read-only
mode
Processors
Standard
handheld
Read/write
heads
for handy
programmers
Handy
programmer
Read/write
gun
Access
protection

Note: 2 read/write heads can


for read/write head BIS C-350 for read/write head BIS C-355/_ _-S92
be operated simultaneously

■ www.balluff.com 167
BIS C Industrial RFID System
Devicenet processors

Cost-effective identification – operate two read/write heads


simultaneously. In a robust metal housing.

Description
Housing material
Devicenet Ordering code
Part number
Supply voltage, Ripple
Current
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Read/write head ports
Service interface
Connection for

Connection type

Accessories included
Accessories (please order separately)

Recommended accessories
(please order separately)

Description Threaded cover


for 7/8" connection
Ordering code BAM012T
Part number BKS-7/8-CS-00-A

168
BIS C Industrial RFID System
Devicenet processors

Processor
Aluminum cast, coated
BIS00AT
BIS C-6023-025-050-03-ST13
24 V DC ±20 %, ≤ 10 % 70 kHz LF
≤ 400 mA
BIS C Industrial
0...+60 °C RFID System
0...+60 °C Range of
IP 65 applications
2× external Read/write
distances
RS232 overview
Read/write heads BIS C-3_ _ Data carriers
read/write
Exception: BIS C-350/BIS C-355
Read/write
1× 7/8" connector male, 5-pin heads
1× 7/8“ connector female, 5-pin Data
couplers
1× M12 connector male, 5-pin
8-bit
1× M12 connector male, 4-pin processor
Software ESD-file for read-only
mode
BIS-C -623 threaded cover 7/8"
Processors
See page 285 for cable options
Standard
Termination resistor page 284/294/305 handheld
Read/write
heads
for handy
programmers
Handy
programmer
Read/write
gun
Access
protection

06Z9
BCC

070K
BCC

070F
BCC

0A09
BCC

■ www.balluff.com 169
BIS C Industrial RFID System
Ethernet/IP processors

Cost-effective identification –
operate 2 read/write heads
simultaneously. In robust metal
housing.

Description Processor
Housing material Aluminum cast, coated
Ethernet/IP Ordering code BIS00AU
Part number BIS C-6026-034-050-06-ST19
Supply voltage, Ripple 24 V DC ±20 %, ≤ 20 %
Current ≤ 400 mA
Operating temperature 0...+60 °C
Storage temperature 0...+60 °C
Degree of protection per IEC 60529 IP 65
Read/write head ports 2× external
Service interface RS232
Connection for Read/write heads BIS C-3_ _
Exception: BIS C-350 and BIS C-355
Connection type 1× M12 connector female, 5-pin, D-coded
1× M12 connector male, 5-pin
1× M12 connector male, 4-pin
Accessories included Configuration software
Connection cable See page 286/292/305 for cable options

170
Ethernet BIS C Industrial RFID System
Ethernet TCP/IP processors
TCP/IP

Description Processor
Housing material Aluminum cast, coated
Ethernet with Ordering code BIS00AY
standard TCP/IP protocol Part number BIS C-6027-039-050-06-ST19
Supply voltage, Ripple 24 V DC ±20 %, ≤ 10 % 70 kHz LF
Current ≤ 400 mA
BIS C Industrial
Operating temperature 0...+60 °C RFID System
Storage temperature 0...+60 °C Range of
Degree of protection per IEC 60529 IP 65 applications
Read/write head ports 2× external Read/write
distances
Service interface RS232 overview
Connection for Read/write heads BIS C-3_ _ Data carriers
read/write
Exception BIS C-350 and BIS C-355
Read/write
Connection type 1× M12 connector female, 5-pin, D-coded heads
1× M12 connector male, 5-pin Data
1× M12 connector male, 4-pin couplers
8-bit
Accessories included Configuration software processor
Connection cable See page 286/292/305 for cable options for read-only
mode
Processors
Standard
handheld
Read/write
heads
for handy
programmers
Handy
programmer
Read/write
gun
Access
protection

Suitable connectors
(please order separately)

Ordering code BCC0C5J


Part number BIS C-526-PU-00,6
Order accessories separately! Adapter cable for Ethernet
from M12, D-coded to coupling RJ45 see connectivity section.

■ www.balluff.com 171
BIS C Industrial RFID System
Profinet processors

Cost-effective identification –
operate two read/write heads
simultaneously.

Description Processor
Housing material ABS
Profinet RT Ordering code BIS00K3
with IRT-capable 2-port switch Part number BIS C-6008-048-650-06-ST23
Supply voltage, Ripple 24 V DC ±10 %, ≤ 10 %
Current ≤ 400 mA
Operating temperature 0...+60 °C
Storage temperature 0...+60 °C
Degree of protection per IEC 60529 IP 65
Read/write head ports 2× external
Service interface RS232 internal
Connection for Read/write heads BIS C-3_ _
Exception: BIS C-350 and BIS C-355
Connection type 1× M12 connector male, 5-pin
2× M12 connector female, 4-pin, D-coded

Accessories included Configuration software


Connection cable See page 286/292/305 for cable options

Adapter or antenna can be


rotated in 3 directions

Suitable connectors
(please order separately)

Ordering code BCC0C5J


Part number BIS C-526-PU-00,6
Order accessories separately! Adapter cable for Ethernet
from M12, D-coded to coupling RJ45 see connectivity section.

172
BIS C Industrial RFID System
Profinet processors

Processor Processor
Aluminum cast, coated Aluminum cast, coated
BIS00TU BIS00K4
BIS C-6028-048-050-06-ST28 BIS C-6028-048-050-06-ST22
24 V DC ±10 %, ≤ 10 % 24 V DC ±10 %, ≤ 10 % 70 kHz LF
≤ 400 mA ≤ 400 mA
BIS C Industrial
0...+60 °C 0...+60 °C RFID System
0...+60 °C 0...+60 °C Range of
IP 65 IP 65 applications
2× external 2× external Read/write
distances
RS232 RS232 overview
Read/write heads BIS C-3_ _ Read/write heads BIS C-3_ _ Data carriers
read/write
Exception BIS C-350 and BIS C-355 Exception BIS C-350 and BIS C-355
Read/write
1× 7/8" connector male, 5-pin 1× Push-pull AIDA connector, 5-pin heads
2× M12 connector female, 4-pin, D-coded 2× Push-pull RJ45 AIDA connector 8-pin Data
couplers
1× M12 connector male, 4-pin 1× M12 connector male, 4-pin
8-bit
Configuration software Configuration software processor
See page 286/292/306 for cable options See page 286/305 for cable options for read-only
mode
Processors
21
Standard
handheld
Read/write
15

heads
for handy
programmers
Handy
programmer
Read/write
gun
145
160

Access
protection

M4
15

15

X4
21 1.0 15 63
60 20 100
The robust version solution for connection to Profinet with AIDA standard
(Automatisierungsinitiative Deutscher Automobilhersteller)

■ www.balluff.com 173
BIS C Industrial RFID System
Standard handheld

For enhanced operating convenience


Allows portable writing and reading of BIS C data carriers.
Easy operation thanks to:
■ Touchscreen with large Windows CE® color display
■ Pre-installed Balluff software and keyboard or stylus

Ideal for poor light conditions and challenging environments.


Data transfer via optional Bluetooth or wired USB. The handheld
is also modular for expandability.

Additional convenience Antenna type


A pistol grip is provided for ergonomic comfort. Function
Housing material
Standard base Ordering code
Part number
Standard + WLAN module Ordering code
Part number
Standard + 1D code reader Ordering code
Part number
Standard + 2D code reader Ordering code
Part number
Standard + ID code reader + WLAN Ordering code
Part number
Standard +2D code reader + WLAN Ordering code
Part number
Keyboard
Display
Supply voltage
Capacity
Interface
Working temperature
Degree of protection per IEC 60529
Read/write head option
Accessories included
Appropriate data carrier

Please order additional accessories separately

Standard handheld BIS C-87_-1-008-X-000_


includes charger and stylus.

Antenna type:

rod

round

Recommended accessories
(please order separately)

Description Pistol grip option Optional docking station


with power supply
Ordering code FHW0004 FHW0003
Part number 11023836 11023834

174
BIS C Industrial RFID System
Standard handheld

General purpose Rod Tool ID


Read/write Read/write Read/write
ABS ABS ABS
BAE00C4 BAE00J6 BAE00CK
BIS C-870-1-008-X-000 BIS C-871-1-008-X-000 BIS C-873-1-008-X-000 70 kHz LF
BAE00CR
BIS C Industrial
BIS C-870-1-008-X-001 BIS C-871-1-008-X-001 BIS C-873-1-008-X-001 RFID System
Range of
BIS C-870-1-008-X-002 BIS C-871-1-008-X-002 BIS C-873-1-008-X-002 applications
Read/write
distances
BIS C-870-1-008-X-003 BIS C-871-1-008-X-003 BIS C-873-1-008-X-003 overview
BAE00JG BAE00E8 Data carriers
read/write
BIS C-870-1-008-X-004 BIS C-871-1-008-X-004 BIS C-873-1-008-X-004
Read/write
heads
BIS C-870-1-008-X-005 BIS C-871-1-008-X-005 BIS C-873-1-008-X-005 Data
52 buttons, alphanumeric 52 buttons, alphanumeric 52 buttons, alphanumeric couplers
8-bit
TFT Touchscreen display TFT Touchscreen display TFT Touchscreen display processor
3.7 V rechargeable battery pack 3.7 V rechargeable battery pack 3.7 V rechargeable battery pack for read-only
mode
4000 mA/h 4000 mA/h 4000 mA/h
Processors
RS232/Balluff Dialog RS232/Balluff Dialog RS232/Balluff Dialog
Standard
–10...+50 °C –10...+50 °C –10...+50 °C handheld
IP 65 IP 65 IP 65 Read/write
heads
Integrated Integrated Integrated for handy
Charging power supply and stylus Charging power supply and stylus Charging power supply and stylus programmers
for BIS C-Data carrier with for BIS C-Data carrier with for BIS C-Data carrier with Handy
programmer
round coil Ø ≥ 35 mm rod antenna round coil Ø ≤ 34 mm
Read/write
Docking station and pistol grip Docking station and pistol grip Docking station and pistol grip gun
Access
100 51 100 51 100 51 protection
Ø14.5
20
265

265

265

■ www.balluff.com 175
BIS C Industrial RFID System
Read/write heads for handy programmers
and read/write gun

Dimensions
Description
Housing material
Ordering code
Part number
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Read head connection
Connection to

Appropriate data carrier

176
BIS C Industrial RFID System
Read/write heads for handy programmers
and read/write gun

Ø 14.5×63 mm Ø 30×66 mm 72×27×27 mm


Read/write head Read/write head Read/write head Adapter cable
Brass, coated POM PVC
BAE0095 BAE0096 BAE0097 BAE0094
BIS C-851 BIS C-852 BIS C-853 BIS C-850 70 kHz LF
0...+70 °C 0...+70 °C 0...+70 °C 0...+70 °C
BIS C Industrial
–20...+85 °C –20...+85 °C –20...+85 °C –20...+85 °C RFID System
IP 67 IP 67 IP 67 IP 67 Range of
6.3 mm jack socket 6.3 mm jack socket 6.3 mm jack socket 6.3 mm jack socket applications
BIS C-810 BIS C-810 BIS C-810 BIS C-810 Read/write
distances
BIS C-820 BIS C-820 BIS C-820 BIS C-820 overview
BIS C-720 BIS C-720 BIS C-720 BIS C-720 Data carriers
read/write
Read/write
heads
BIS C-100_ _ BIS C-100_ _ BIS C-150-_ _/A Data
BIS C-103_ _ BIS C-104_ _ couplers
8-bit
BIS C-105_ _ BIS C-108_ _ Adapter cable for handy processor
BIS C-121_ _ BIS C-117_ _ programmer or portable for read-only
mode
BIS C-122_ _ BIS C-128_ _ device and all read/write
Processors
BIS C-130_ _ heads with M12 connector. Standard
BIS C-190_ _ handheld
BIS C-191_ _ Read/write
heads
for handy
Sensing
programmers
face
Ø30 Handy
Sensing Sensing
face face programmer
Read/write
13

gun
Access
protection
66
97

Ø6.3

■ www.balluff.com 177
BIS C Industrial RFID System
Handy programmer

For maximum flexibility


The handy programmer with read/write function helps you stay
mobile and independent. Benefit from increased mobility during
repair work, for example. The handy programmer is fitted with
an interface for connection to a PC. Option of customizing menu
buttons.

Function
Housing material
Ordering code
Part number
Keyboard
Display
Current
Capacity
Interface
Operating temperature
Degree of protection per IEC 60529
Read head connection
Accessories

Recommended accessories
(please order separately)

Description C
Charger Ch
Charging
i cradle
dl with
ith charging
h power supply
Ordering code BAE0047 BAE0048
Part number BIS C-701-A BIS C-702-A

178
BIS C Industrial RFID System
Handy programmer

Handy programmer Handy programmer


ABS ABS
BAE0088 BAE008C
BIS C-810-0-003 BIS C-820-0-004-D
32 buttons, alphanumeric 1 key 70 kHz LF
LCD-display, 20 characters in 4 line 2 LED status/battery
BIS C Industrial
2.4 V rechargeable battery pack NiMH 2× R6 AA rechargeable NiMH RFID System
1500 mA/h 800 mA/h Range of
RS232, Balluff Dialog RS232, Balluff Dialog applications
0...+50 °C 0...+50 °C Read/write
distances
IP 40 IP 40 overview
1× 6.3 mm jack socket 1× 6.3 mm jack socket Data carriers
read/write
Carrying case included
Read/write
heads
Data
couplers
8-bit
processor
for read-only
mode
Processors
Standard
handheld
Read/write
heads
for handy
programmers
Handy
programmer
Read/write
gun
Access
protection

BIS C-820

BIS C-522-PVC-02

RS232 adapter cable


BIS C-522-PVC-02
BIS C-524-PVC-01,5
on page 285.

Please order separately!

■ www.balluff.com 179
BIS C Industrial RFID System
Read/write gun

Outstanding operating comfort


Benefit from the advantages of the ergonomic pistol grip with the
option of attaching three different read/write heads. The pistol grip
rests snugly in your hand while you activate a read/write function at
the press of a button. LEDs and an integral buzzer signal the end
of the read/write process.

Description
Housing material
Ordering code
Part number
Keyboard
Display
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Read head connection
Coiled cable extended
Connection to

See read/write head attachments


hments on page 176

180
BIS C Industrial RFID System
Read/write gun

Read/write gun
PA 66
BAE004C
BIS C-720-01-03
1 key 70 kHz LF
1 LED
BIS C Industrial
0...+70 °C RFID System
–20...+85 °C Range of
IP 40 applications
6.3 mm jack socket Read/write
distances
3m overview
Processor and PLC Data carriers
read/write
Read/write
heads
Data
couplers
8-bit
processor
for read-only
mode
Processors
Standard
handheld
Read/write
heads
for handy
programmers
Handy
programmer
Read/write
gun
Access
protection

■ www.balluff.com 181
BIS C Industrial RFID System
Access protection

Access protection
And here's how it works: Individual access codes are allocated
via programmable data keys, which can then be disabled to prevent
further programming.
Unauthorized personnel cannot manipulate the data key as a result.
The data key is read via an antenna fitted to a special bracket. The
processor unit then issues the data.
Different interfaces such as serial, Profibus, Interbus, Devicenet,
Ethernet/IP or parallel interfaces enable simple connection to the
monitored system. Available for systems BIS C, BIS L and BIS M.
Version
The benefits to you Use
Simple upgrade and rapid replacement without modifying the system Housing material
software. End users are independent of system providers. The Ordering code
access system is easy to integrate in read/write stations that already Part number
use an identification system. Simply connect the access monitoring Operating temperature
antenna to the second channel on the existing processor unit. Hard- Storage temperature
ware expenses are reduced to a minimum and software only requires Degree of protection per IEC 60529
slight modification in order to process both channels.

Electronic key for access control.


Easy to implement using the "RFID key".

182
BIS C Industrial RFID System
Access protection

Access protection Data carrier and bracket


Attachment for read/write head BIS C-300 Used with BIS C-300-ZA1
POM and PA 6.6 POM and PA 12
BAM012C BIS002Y
BIS C-300-ZA1 BIS C-122-04/L-ZC1 70 kHz LF
0...+70 °C –25...+70 °C
BIS C Industrial
–20...+85 °C –25...+85 °C RFID System
IP 67 Range of
applications
Read/write
Sensing distances
face overview
Data carriers
read/write
Read/write
heads
Data
couplers
8-bit
processor
for read-only
mode
Processors
Standard
handheld
Read/write
heads
for handy
programmers
Handy
programmer
Read/write
gun
Access
protection

■ www.balluff.com 183
BIS L
Industrial
RFID
125 kHz LF
System
Inductive Identification
The cost-effective BIS L is used in logistics and on assembly lines.
It uses a LF 125 kHz technology along with passive tags to provide
shorter range RFID solutions.

Host
controller
PLC, PC
Serial
Profibus
Devicenet

Interface
variations
Serial
Profibus
Devicenet
Ethernet/IP
Ethernet TCP/IP

V-Processor

Serial/Parallel/IO-Link
Interface

Windows®
based handheld

Processors

Read/write
heads

Data carriers

184
BIS L Industrial RFID System
Inductive identification

Range of applications 186


Read/write distances overview 188
Data carriers read/write 192
Data carriers read only 194
Read/write heads 196
Data couplers 208
Read only compact processors
parallel 210
serial 214
IO-Link 216
easy loop® 218
Processors Serial RS232 220
Profibus 220
Devicenet 224
Ethernet/IP 226
Ethernet TCP/IP 227
BIS V – New Generation 228
Communication module for easy loop® 230
Standard handheld 232
Access protection 234 125 kHz LF

Basic information
and definitions
can be found on
page 352

■ www.balluff.com 185
BIS L Industrial RFID System
Range of applications

Select the most suitable BIS L system for your application from
the table and benefit from the outstanding performance and quality
of economical industrial RFID systems.

Data carrier

Page
BIS0033 BIS L-100-01/L 192
BIS0035 BIS L-100-05/L-RO 195
BIS0036 BIS L-101-01/L 193
BIS0038 BIS L-101-05/L-RO 195
BIS0039 BIS L-102-01/L 193
BIS003C BIS L-102-05/-RO 195
BIS003E BIS L-103-05/L 193
BIS003F BIS L-103-05/L-RO 195
BIS00ZY BIS L-103-05/L-ZC1 235
BIS003N BIS L-150-05/A 193
BIS003R BIS L-200-03/L 195
BIS003T BIS L-201-03/L 195
BIS003U BIS L-202-03/L 195
BIS003W BIS L-203-03/L 195

186



On tool
Tool and die management





Dies

Production









■ www.balluff.com
Pallets Assembly conveying systems







Retainer/workpiece carrier
Closed logistics circuits







Pallets








Retainer/workpiece carrier
Storage and
retrieval equipment




Workpiece carrier skid
Intralogistics


Guiding, steering
Driverless vehicles








Identification


In component
Object detection


On component



Range of applications

Reliable access control


Access and
object control



Process access Access and entry control



Part ID
BIS L Industrial RFID System






Read/write


Installation in metal







Long distances (> 16 mm)







192 Byte Read/write EEPROM





3 Byte + CRC
Read only



5 Byte
Data

187
heads

Access
couplers

compact
overview

Standard
read only

handheld
distances
Range of

Read only

protection
read/write

Communi-
Read/write
Read/write

easy loop®
processors
Processors
Data carriers
Data carriers
applications
RFID System

cation module
125 kHz LF
BIS L Industrial
BIS L Industrial RFID System
Read/write distances overview

How much data do you require? ■ Then determine your read/write distance, which also depends
How dynamic is your application? on the speed of your system: the faster the data carrier moves,
In three steps you will have selected your BIS L system: the closer the distance needs to be.
■ First choose the appropriate form factor for your data carrier ■ Finally, determine the desired memory capacity.
and the associated read/write heads. This will give you the maximum data security.

Mounting Data carrier 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 90 100 mm


BIS L-300-…
BIS L-100-01 0...30
10...20
10...20
BIS L-101-01 0...40
10...30
10...30
BIS L-102-01 0...55
15...40
15...35
BIS L-103-05/L 7...40
7...18
8...15
BIS L-150-05 0...25
BIS L-200-03/L* 0...40
10...25
10...20
BIS L-201-03/L* 0...50
10...35
10...30
BIS L-202-03/L* 0...70
15...45
15...40
BIS L-203-03/L* 0...25
3...12
3...10
BIS L-100-05/L-RO* 0...40
10...25
10...20
BIS L-101-05/L-RO* 0...50
10...35
10...30
BIS L-102-05/L-RO* 0...70
15...45
15...40
BIS L-103-05/L-RO* 0...25
3...12
3...10
BIS L-301-…
BIS L-100-01/L 0...40
15...30
15...25
BIS L-101-01/L 0...55
15...40
15...35
BIS L-102-01/L 0...70
20...50
20...50
BIS L-150-05/A 0...32
BIS L-200-03/L* 0...70
20...50
20...50
BIS L-201-03/L* 0...70
20...45
20...40
BIS L-202-03/L* 0...100
25...60
25...55
BIS L-100-05/L-RO* 0...70
20...50
20...50
BIS L-101-05/L-RO* 0...70
20...45
20...40
BIS L-102-05/L-RO* 0...100
25...60
25...55
BIS L-303-S115
BIS L-100-01/L 0...40
BIS L-101-01/L 0...55
BIS L-102-01/L 0...70
BIS L-200-03/L* 0...50
BIS L-201-03/L* 0...70
BIS L-202-03/L* 0...100
BIS L-100-05/L-RO* 0...50
BIS L-101-05/L-RO* 0...70
BIS L-102-05/L-RO* 0...100

flush in steel non-flush on steel non-metal


* read only
188
BIS L Industrial RFID System
Read/write distances overview

Mounting Data carrier 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 90 100 mm


BIS L-302-S115
BIS L-100-01/L 0...20
8...15
8...15
BIS L-101-01/L 0...25
10...20
10...20
BIS L-102-01/L 0...30
10...25
10...20
BIS L-103-05/L 10...22
10...15
7...8
BIS L-150-05/A 0...12
BIS L-200-03/L* 0...25
8...15
8...15
BIS L-201-03/L* 0...30
10...20
10...20
BIS L-202-03/L* 0...40
10...25
10...20
BIS L-203-03/L* 0...15
4...10
3...8
BIS L-100-05/L-RO* 0...25 125 kHz LF
8...15
8...15 BIS L Industrial
RFID System
BIS L-101-05/L-RO* 0...30
10...20 Range of
applications
10...20
BIS L-102-05/L-RO* 0...40 Read/write
distances
10...25 overview
10...20
BIS L-103-05/L-RO* 0...15 Data carriers
read/write
4...10
3...8 Data carriers
read only
BIS L-304-…
BIS L-100-01/L 0...20 Read/write
heads
8...15
8...15 Data
BIS L-101-01/L 0...25 couplers
10...20 Read only
10...20 compact
processors
BIS L-102-01/L 0...30
10...25 Processors
10...20 easy loop®
BIS L-103-05/L 10...22 Communi-
10...15 cation module
7...8 Standard
BIS L-150-05/A 0...12 handheld
BIS L-200-03/L* 0...25 Access
8...15 protection
8...15
BIS L-201-03/L* 0...30
10...20
10...20
BIS L-202-03/L* 0...40
10...25
10...20
BIS L-203-03/L* 0...15
4...10
3...8
BIS L-100-05/L-RO* 0...25
8...15
8...15
BIS L-100-05/L-RO* 0...30
10...20
10...20
BIS L-102-05/L-RO* 0...40
10...25
10...20
BIS L-103-05/L-RO* 0...15
4...10
3...8
BIS L-306-…
BIS L-103-05/L 0...7
BIS L-100-05/L 0...15
BIS L-203-03/L* 0...7
BIS L-103-05/L-RO* 0...7
BIS L-350-…
BIS L-150-05/A 0...17
0...24
0...24

■ www.balluff.com 189
BIS L Industrial RFID System
Read/write distances overview

Mounting Data carrier 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 90 100 mm


BIS L-405-03_-001-05-MU
BIS L-200-03/L* 0...30
BIS L-100-05/L-RO* 0...30
BIS L-201-03/L* 0...40
BIS L-101-05/L-RO* 0...40
BIS L-202-03/L* 0...55
BIS L-102-05/L-RO* 0...55
BIS L-203-03/L* 0...20
BIS L-103-05/L-RO* 0...20
BIS L-405-03_-003-05-MU
BIS L-203-03/L* 0...23
BIS L-103-05/L-RO* 0...23
BIS L-405-03_-002-05-MU
BIS L-405-03_-004-05-MU
BIS L-200-03/L* 0...23
BIS L-100-05/L-RO* 0...23
BIS L-201-03/L* 0...27
BIS L-101-05/L-RO* 0...27
BIS L-203-03/L* 0...16
BIS L-103-05/L-RO* 0...16
BIS L-400-035-001-0_-S115
BIS L-200-03/L* 0...30
BIS L-100-05/L-RO* 0...30
BIS L-201-03/L* 0...40
BIS L-101-05/L-RO* 0...40
BIS L-202-03/L* 0...55
BIS L-102-05/L-RO* 0...55
BIS L-203-03/L* 0...20
BIS L-103-05/L-RO* 0...20
BIS L-400-035-003-0_-S115
BIS L-203-03/L* 0...11
BIS L-103-05/L-RO* 0...11
BIS L-400-035-002-0_-S115
BIS L-400-035-004-00-S115
BIS L-200-03/L* 0...23
BIS L-100-05/L-RO* 0...23
BIS L-201-03/L* 0...27
BIS L-101-05/L-RO* 0...27
BIS L-203-03/L* 0...16
BIS L-103-05/L-RO* 0...16
BIS L-409-045-001-07-S4
BIS L-200-03/L* 0...25
BIS L-100-05/L-RO* 0...25
BIS L-201-03/L* 0...35
BIS L-101-05/L-RO* 0...35
BIS L-202-03/L* 0...48
BIS L-102-05/L-RO* 0...48
BIS L-203-03/L* 0...16
BIS L-103-05/L-RO* 0...16
BIS L-409-045-003-07-S4
BIS L-203-03/L* 0...7
BIS L-103-05/L-RO* 0...7
BIS L-409-045-002-07-S4
BIS L-409-045-004-07-S4
BIS L-200-03/L* 0...15
BIS L-100-05/L-RO* 0...15
BIS L-201-03/L* 0...18
BIS L-101-05/L-RO* 0...18
BIS L-203-03/L* 0...10
BIS L-103-05/L-RO* 0...10
BIS L-400-043-001-02-S115
BIS L-200-03/L* 0...30
BIS L-100-05/L-RO* 0...30
BIS L-201-03/L* 0...40
BIS L-101-05/L-RO* 0...40
BIS L-202-03/L* 0...55
BIS L-102-05/L-RO* 0...55
BIS L-203-03/L* 0...20
BIS L-103-05/L-RO* 0...20
BIS L-400-043-003-02-S115
BIS L-203-03/L* 0...11
BIS L-103-05/L-RO* 0...11
BIS L-400-043-002-02-S115
BIS L-400-043-004-02-S115
BIS L-200-03/L* 0...23
BIS L-100-05/L-RO* 0...23
BIS L-201-03/L* 0...27
BIS L-101-05/L-RO* 0...27
BIS L-203-03/L* 0...16
BIS L-103-05/L-RO* 0...16

flush in steel non-flush on steel non-metal


* read only

190
BIS L Industrial RFID System
Read/write distances overview

125 kHz LF
BIS L Industrial
RFID System
Range of
applications
Read/write
distances
overview
Data carriers
read/write
Data carriers
read only
Read/write
heads
Data
couplers
Read only
compact
processors
Processors
easy loop®
Communi-
cation module
Standard
handheld
Access
protection

■ www.balluff.com 191
BIS L Industrial RFID System
Data carriers read/write

For harsh environments


■ Housing material extremely
resistant to chemicals
■ Compact designs for
special applications

Dimensions Ø 20×1.6 mm
Housing material EP
Weight 1.4 g

BIS L programmable
192 bytes Ordering code BIS0033
Part number BIS L-100-01/L
Operating temperature –25...+85 °C
Storage temperature –40...+95 °C
Degree of protection per IEC 60529 IP 67

Appropriate read/write head with max. read/write distance


Mounting
BIS L-300 30 mm 20 mm 20 mm
BIS L-301 40 mm 30 mm 25 mm
BIS L-302 20 mm 15 mm 15 mm
BIS L-303 50 mm 14 mm
BIS L-304 20 mm 15 mm 15 mm
BIS L-306 15 mm
BIS L-350

For installation pay attention to Basic Information chapter.


Sensing
Mounting:
face
flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

192
BIS L Industrial RFID System
Data carriers read/write

Ø 30×1.6 mm Ø 50×1.6 mm Ø 12.4×2 mm Ø 3.15×13.3 mm


EP EP EP Glass
2.6 g 6.5 g 0.8 g 0.22 g

BIS0036 BIS0039 BIS003E BIS003N


BIS L-101-01/L BIS L-102-01/L BIS L-103-05/L BIS L-150-05/A
–25...+85 °C –25...+85 °C –25...+85 °C –40...+85 °C
–40...+95 °C –40...+95 °C –40...+130 °C –40...+90 °C
IP 67 IP 67 IP 68 IP 68
125 kHz LF
BIS L Industrial
RFID System
Range of
40 mm 30 mm 30 mm 55 mm 40 mm 35 mm 10 mm 18 mm 12 mm 25 mm applications
55 mm 40 mm 35 mm 70 mm 50 mm 50 mm 32 mm Read/write
distances
25 mm 20 mm 20 mm 30 mm 25 mm 20 mm 22 mm 15 mm 8 mm 12 mm overview
65 mm 25 mm 15 mm 85 mm 30 mm 25 mm Data carriers
25 mm 20 mm 20 mm 30 mm 25 mm 20 mm 22 mm 15 mm 8 mm 12 mm read/write
7 mm Data carriers
read only
17 mm 24 mm 24 mm Read/write
heads
Data
couplers
Sensing Sensing Sensing Sensing Read only
face face face face compact
processors
Sensing face Processors
BIS L-350-S115
easy loop®
Communi-
cation module
Standard
handheld
Access
protection

Glass data carrier –


Tightening torque max. 1 Nm Tightening torque max. 1 Nm For metal
chemically resistant!

Ordering code BIS003L


Part number BIS L-130-05/L-SA1
For radial data retrieval from rotating parts, positioning not required.
Contact us.

■ www.balluff.com 193
BIS L Industrial RFID System
Data carriers read only

For maximum data security


The CRC-16 procedure involves writing a test code to the data
carrier to allow you to control data anywhere at any time. The
benefit to you: high level of data security even in non-active phase
(data carrier outside of R/W head). The procedure is only possible
with data carriers of type BIS L-1_ _-05/L, which are converted into
read-only format.
BIS L-1_ _-05/L-RO are read-only data carriers that can be pro-
grammed according to your requirements. Please ask for the order
form or download it from our website. 3 bytes of user data as well
as 2 bytes for the CRC are stored. Data consistency is queried by Dimensions
the processor. Housing material
The BIS L-2_ _-03/L uses read-only data carriers with a fixed Weight
"unique number" of 5 bytes (40 bits). No repetition of the unique
number or delivery of sequential numbers is possible. BIS L read-only
24 bits + CRC Ordering code
Part number
Read-only data carriers: preprogram your individual data and
40 bits Ordering code
benefit from maximum data security
Part number
Operating temperature
Storage temperature
Degree of protection per IEC 60529

Appropriate read/write head with max. read/write distance


Mounting
BIS L-300
BIS L-301
BIS L-302
BIS L-303
BIS L-304
BIS L-306

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

194
BIS L Industrial RFID System
Data carriers read only

Ø 20×1.6 mm Ø 30×1.6 mm Ø 50×1.6 mm Ø 12.4×2 mm


EP EP EP EP
1.4 g 2.6 g 6.5 g 0.8 g

BIS0035 BIS0038 BIS003C BIS003F


BIS L-100-05/L-RO BIS L-101-05/L-RO BIS L-102-05/L-RO BIS L-103-05/L-RO
BIS003R BIS003T BIS003U BIS003W
BIS L-200-03/L BIS L-201-03/L BIS L-202-03/L BIS L-203-03/L
–40...+85 ºC –40...+85 ºC –40...+85 ºC –25...+85 ºC
–40...+95 ºC –40...+95 ºC –40...+95 ºC –40...+130 ºC 125 kHz LF
IP 67 IP 67 IP 67 IP 68 BIS L Industrial
RFID System
Range of
applications
Read/write
40 mm 25 mm 20 mm 50 mm 35 mm 30 mm 70 mm 45 mm 40 mm 25 mm 10 mm distances
overview
50 mm 35 mm 30 mm 70 mm 45 mm 40 mm 100 mm 60 mm 55 mm
Data carriers
25 mm 15 mm 15 mm 30 mm 20 mm 20 mm 40 mm 25 mm 20 mm 15 mm 8 mm read/write
55 mm 70 mm 30 mm 15 mm 100 mm 45 mm 40 mm Data carriers
25 mm 15 mm 15 mm 30 mm 20 mm 20 mm 40 mm 25 mm 20 mm 15 mm 8 mm read only
7 mm Read/write
heads
Data
couplers
Read only
Sensing Sensing Sensing Sensing compact
face face face face processors
Processors
easy loop®
Communi-
cation module
Standard
handheld
Access
protection

Tightening torque max. 1 Nm Tightening torque max. 1 Nm

■ www.balluff.com 195
BIS L Industrial RFID System
Read/write heads

Dimensions
Housing material
For standard processor Ordering code
Part number
For BIS V processor Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection to
Connection cable

Ordering code
Part number
Ordering code
Appropriate data carrier Part number
Mounting
Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
3 mm
8 mm
10 mm
12 mm
15 mm
20 mm
25 mm
30 mm
35 mm
40 mm
45 mm
50 mm
55 mm
60 mm
70 mm

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

196
BIS L Industrial RFID System
Read/write heads

M30×1.5
0 15
PA 66
BIS004R
BIS L-300-S115
BIS00UL
BIS VL-300-001-S4

0...+70 °C (minus temperatures on request)


–20...+85 °C
IP 67
125 kHz LF
Processor
See page 280 for cable options BIS L Industrial
RFID System
Range of
BIS0033 BIS0036 BIS0039 BIS003E BIS003N BIS003R BIS003T BIS003U BIS003W applications
BIS L-100-01 BIS L-101-01 BIS L-102-01 BIS L-103-05/L BIS L-150-05 BIS L-200-03/L BIS L-201-03/L BIS L-202-03/L BIS L-203-03/L Read/write
distances
BIS0035 BIS0038 BIS003C BIS003F overview
BIS L-100-05/L-RO BIS L-101-05/L-RO BIS L-102-05/L-RO BIS L-103-05/L-RO Data carriers
read/write
0...30 10...20 10...20 0...40 10...30 10...30 0...55 15...40 15...35 7...40 7...18 8...15 0...25 Data carriers
read only
0...30 10...20 10...20 0...40 10...30 10...30 0...55 15...40 15...35 7...40 7...18 8...15 0...25 0...40 10...25 10...20 0...50 10...35 10...30 0...70 15...45 15...40 0...25 3...12 3...10 Read/write
±18 ±28 ±30 ±18 ±20 ±28 ±35 ±15 heads
±18 ±28 ±30 ±18 ±20 ±28 ±35 ±15 ±12 ±9 Data
couplers
±18 ±28 ±30 ±15 ±10 ±5 ±18 ±20 ±28 ±35 ±15 ±12 ±8
Read only
±18 ±8 ±8 ±28 ±15 ±13 ±30 ±15 ±10 ±5 ±18 ±20 ±15 ±10 ±28 ±20 ±17 ±35 ±15 ±9 ±7 compact
±18 ±8 ±8 ±28 ±15 ±13 ±30 ±15 ±10 ±5 ±17 ±20 ±15 ±10 ±28 ±20 ±17 ±35 ±15 processors
Processors
±18 ±5 ±5 ±28 ±15 ±10 ±30 ±20 ±20 ±15 ±10 ±3 ±17 ±20 ±10 ±10 ±28 ±20 ±17 ±35 ±25 ±20 ±15
easy loop®
±18 ±0 ±0 ±28 ±15 ±10 ±30 ±20 ±15 ±15 ±17 ±20 ±10 ±0 ±28 ±20 ±17 ±35 ±25 ±20 ±15 Communi-
±18 ±28 ±10 ±5 ±30 ±15 ±15 ±15 ±14 ±20 ±0 ±28 ±20 ±15 ±35 ±20 ±20 ±13 cation module
±18 ±28 ±0 ±0 ±30 ±15 ±10 ±15 ±20 ±28 ±15 ±0 ±35 ±20 ±20 Standard
handheld
±28 ±30 ±15 ±0 ±5 ±20 ±28 ±0 ±35 ±15 ±15 Access
±28 ±30 ±0 ±20 ±28 ±35 ±12 ±0 protection
±30 ±28 ±35 ±0
±30 ±28 ±35
±35
±35
±35

Sensing
face

Example:
BIS L-300-S115 BIS Z-501-PU-_ _

BIS L-6021-_ _ _-050-03-ST8

■ www.balluff.com 197
BIS L Industrial RFID System
Read/write heads

Dimensions
Housing material
For standard processor Ordering code
Part number
For BIS V processor Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection to
Connection cable

Ordering code
Part number
Ordering code
Appropriate data carrier Part number
Mounting
Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
3 mm
8 mm
10 mm
15 mm
20 mm
25 mm
30 mm
35 mm
40 mm
45 mm
50 mm
55 mm
60 mm
70 mm
100 mm

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

198
BIS L Industrial RFID System
Read/write heads

80×80×40
×80×40 mm
PBT
BIS004T
BIS L-301-S115
BIS00U6
BIS VL-301-001-S4

0...+70 °C (minus temperatures on request)


–20...+85 °C
IP 67
125 kHz LF
Processor
See page 280 for cable options BIS L Industrial
RFID System
Range of
BIS0033 BIS0036 BIS0039 BIS003N BIS003R BIS003T BIS003U applications
BIS L-100-01/L BIS L-101-01/L BIS L-102-01/L BIS L-150-05/A BIS L-200-03/L BIS L-201-03/L BIS L-202-03/L Read/write
distances
BIS0035 BIS0038 BIS003C overview
BIS L-100-05/L-RO BIS L-101-05/L-RO BIS L-102-05/L-RO Data carriers
read/write
0...40 15...30 15...25 0...55 15...40 15...35 0...70 20...50 20...50 0...32 Data carriers
read only
0...40 15...30 15...25 0...55 15...40 15...35 0...70 20...50 20...50 0...32 0...70 20...50 20...50 0...70 20...45 20...40 0...100 25...60 25...55 Read/write
±30 ±35 ±40 ±24 ±40 ±40 ±45 heads
±30 ±35 ±40 ±24 ±40 ±40 ±45 Data
couplers
±30 ±35 ±40 ±24 ±40 ±40 ±45
Read only
±30 ±35 ±40 ±24 ±40 ±40 ±45 compact
±30 ±20 ±15 ±35 ±20 ±20 ±40 ±24 ±40 ±40 ±45 processors
Processors
±30 ±15 ±10 ±35 ±20 ±20 ±40 ±25 ±22 ±24 ±40 ±25 ±22 ±40 ±24 ±20 ±45
easy loop®
±30 ±10 ±0 ±35 ±20 ±15 ±40 ±25 ±22 ±24 ±40 ±25 ±22 ±40 ±24 ±20 ±45 ±30 ±30 Communi-
±30 ±0 ±35 ±20 ±15 ±40 ±25 ±22 ±24 ±40 ±25 ±22 ±40 ±20 ±20 ±45 ±30 ±30 cation module
±30 ±35 ±15 ±0 ±40 ±20 ±15 ±40 ±20 ±15 ±40 ±20 ±15 ±45 ±30 ±25 Standard
handheld
±30 ±35 ±0 ±40 ±15 ±15 ±40 ±15 ±15 ±40 ±18 ±0 ±45 ±30 ±25 Access
±35 ±40 ±15 ±10 ±40 ±15 ±10 ±40 ±0 ±45 ±25 ±20 protection
±35 ±40 ±0 ±0 ±40 ±0 ±0 ±40 ±45 ±20 ±20
±35 ±40 ±40 ±40 ±45 ±10 ±0
±40 ±40 ±40 ±45 ±0
±40 ±40 ±40 ±45
±45

Sensing
face

■ www.balluff.com 199
BIS L Industrial RFID System
Read/write heads

Suitable for roller conveyors/internal company logistics

Dimensions
Housing material
For standard processor Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection to
Connection cable

Ordering code
Part number
Ordering code
Appropriate data carrier Part number
Mounting
Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
3 mm
8 mm
10 mm
15 mm
20 mm
25 mm
30 mm
35 mm
40 mm
45 mm
50 mm
55 mm
60 mm
70 mm
100 mm

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

200
BIS L Industrial RFID System
Read/write heads

170×80×50 mm
PBT
BIS004Y
BIS L-303-S115

0...+70 °C (minus temperatures on request)


–20...+85 °C
IP 67
Processor
See page 280 for cable options
125 kHz LF

BIS0033 BIS0036 BIS0039 BIS003R BIS003T BIS003U BIS L Industrial


RFID System
BIS L-100-01/L BIS L-101-01/L BIS L-102-01/L BIS L-200-03/L BIS L-201-03/L BIS L-202-03/L
Range of
BIS0035 BIS0038 BIS003C applications
BIS L-100-05/L-RO BIS L-101-05/L-RO BIS L-102-05/L-RO Read/write
distances
overview
0...40 0...55 0...70 Data carriers
0...40 0...55 0...70 0...50 0...70 0...100 read/write
±30 ±35 ±40 ±35 ±40 ±45 Data carriers
read only
±30 ±35 ±40 ±35 ±40 ±45 Read/write
±30 ±35 ±40 ±35 ±40 ±45 heads
±30 ±35 ±40 ±35 ±40 ±45 Data
couplers
±30 ±35 ±40 ±35 ±40 ±45
Read only
±30 ±35 ±40 ±35 ±40 ±45 compact
±30 ±35 ±40 ±35 ±40 ±45 processors
Processors
±30 ±35 ±40 ±35 ±40 ±45
easy loop®
±30 ±35 ±40 ±35 ±40 ±45 Communi-
±30 ±35 ±40 ±35 ±40 ±45 cation module
±35 ±40 ±35 ±40 ±45 Standard
handheld
±35 ±40 ±35 ±40 ±45 Access
±35 ±40 ±40 ±45 protection
±40 ±40 ±45
±40 ±40 ±45
±45

Sensing
face

■ www.balluff.com 201
BIS L Industrial RFID System
Read/write heads

Use small read heads with processor electronics


if the available width is limited

Dimensions
Housing material
For standard processor Ordering code
Part number
For BIS V processor Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection to
Connection cable

Ordering code
Part number
Ordering code
Appropriate data carrier Part number
Mounting
Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
3 mm
4 mm
7 mm
8 mm
10 mm
12 mm
15 mm
20 mm
25 mm
30 mm
35 mm
40 mm

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

202
BIS L Industrial RFID System
Read/write heads

M18×1
Aluminum, anodized and brass, coated
BIS004U
BIS L-302-S115
BIS00UF
BIS VL-302-001-S4

0...+70 °C (minus temperatures on request)


–20...+85 °C
IP 67
125 kHz LF
Processor
See page 274/280 for cable options BIS L Industrial
RFID System
Range of
BIS0033 BIS0036 BIS0039 BIS003E BIS003N BIS003R BIS003T BIS003U BIS003W applications
BIS L-100-01/L BIS L-101-01/L BIS L-102-01/L BIS L-103-05/L BIS L-150-05/A BIS L-200-03/L BIS L-201-03/L BIS L-202-03/L BIS L-203-03/L Read/write
distances
BIS0035 BIS0038 BIS003C BIS003F overview
BIS L-100-05/L-RO BIS L-101-05/L-RO BIS L-102-05/L-RO BIS L-103-05/L-RO Data carriers
read/write
0...20 8...15 8...15 0...25 10...20 10...20 0...30 10...25 10...20 10...22 10...15 7...8 0...12 Data carriers
read only
0...20 8...15 8...15 0...25 10...20 10...20 0...30 10...25 10...20 10...22 10...15 7...8 0...12 0...25 8...15 8...15 0...30 10...20 10...20 0...40 10...25 10...20 0...15 4...10 3...8 Read/write
±10 ±12 ±15 ±8 ±13 ±15 ±20 ±6 heads
±10 ±12 ±15 ±8 ±13 ±15 ±20 ±6 ±7 ±5 Data
couplers
±10 ±12 ±15 ±8 ±13 ±15 ±20 ±6 ±7 ±5
Read only
±10 ±12 ±15 ±3 ±8 ±13 ±15 ±20 ±6 ±7 ±4 compact
±10 ±6 ±6 ±12 ±15 ±2 ±8 ±13 ±8 ±6 ±15 ±20 ±6 ±6 ±3 processors
Processors
±10 ±5 ±5 ±12 ±10 ±8 ±15 ±15 ±10 ±10 ±6 ±8 ±13 ±8 ±6 ±15 ±10 ±10 ±20 ±15 ±8 ±6 ±5
easy loop®
±10 ±4 ±4 ±12 ±10 ±8 ±15 ±15 ±10 ±10 ±6 ±8 ±13 ±8 ±6 ±15 ±10 ±10 ±20 ±15 ±8 ±6 Communi-
±10 ±0 ±0 ±12 ±5 ±5 ±15 ±15 ±5 ±10 ±2 ±13 ±0 ±0 ±15 ±10 ±8 ±20 ±15 ±6 ±6 cation module
±10 ±12 ±0 ±0 ±15 ±10 ±0 ±5 ±13 ±15 ±0 ±0 ±20 ±10 ±0 Standard
handheld
±12 ±15 ±0 ±13 ±15 ±20 ±0 Access
±15 ±15 ±20 protection
±20
±20

Sensing
face

Cable length 500 mm

■ www.balluff.com 203
BIS L Industrial RFID System
Read/write heads

Select a flat design if the available height is limited

Dimensions 25×50×10
5×50×10 mm
Housing material Aluminum, anodized and ABS
For standard processor Ordering code BIS004Z
Part number BIS L-304-S115
For BIS V processor Ordering code BIS00UH
Part number BIS VL-304-001-S4
Mounting
Operating temperature 0...+70 °C (minus temperatures on request)
Storage temperature –20...+85 °C
Degree of protection per IEC 60529 IP 67
Connection to Processor
Connection cable See page 274/280 for cable options

Ordering code BIS0033 BIS0036 BIS0039 BIS003E


Part number BIS L-100-01/L BIS L-101-01/L BIS L-102-01/L BIS L-103-05/L
Ordering code
Appropriate data carrier Part number
Mounting
Write distance in mm 0...20 8...15 8...15 0...25 10...20 10...20 0...30 10...25 10...20 10...22 10...15 7...8
Read distance in mm 0...20 8...15 8...15 0...25 10...20 10...20 0...30 10...25 10...20 10...22 10...15 7...8
Offset in mm at distance 0 mm ±10 ±12 ±15
3 mm ±10 ±12 ±15
4 mm ±10 ±12 ±15
7 mm ±10 ±12 ±15 ±3
8 mm ±10 ±6 ±6 ±12 ±15 ±2
10 mm ±10 ±5 ±5 ±12 ±10 ±8 ±15 ±15 ±10 ±10 ±6
12 mm ±10 ±3 ±3 ±12 ±10 ±8 ±15 ±15 ±10 ±10 ±6
15 mm ±10 ±0 ±0 ±12 ±5 ±5 ±15 ±15 ±5 ±10 ±2
20 mm ±10 ±12 ±0 ±0 ±15 ±10 ±0 ±5
25 mm ±12 ±15 ±0
30 mm ±15
35 mm
40 mm

For installation pay attention to Basic Information chapter.

Mounting: Sensing
face
flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round Cable length 500 mm

204
BIS L Industrial RFID System
Read/write heads

M12×1
Aluminum, anodized and brass, coated
BIS00RN
BIS L-306-S115
BIS00UJ
BIS VL-306-001-S4

0...+70 °C
–20...+85 °C
IP 67
125 kHz LF
Processor
See page 274/280 for cable options BIS L Industrial
RFID System
Range of
BIS003N BIS003R BIS003T BIS003U BIS003W BIS003W BIS003E BIS0033 applications
BIS L-150-05/A BIS L-200-03/L BIS L-201-03/L BIS L-202-03/L BIS L-203-03/L BIS L-203-03/L BIS L-103-05/L BIS L-100-05/L Read/write
distances
BIS0035 BIS0035 BIS003C BIS003F BIS003F overview
BIS L-100-05/L-RO BIS L-100-05/L-RO BIS L-102-05/L-RO BIS L-103-05/L-RO BIS L-103-05/L-RO Data carriers
read/write
0...12 0...7 0...15 Data carriers
read only
0...12 0...25 8...15 8...15 0...30 10...20 10...20 0...40 10...25 10...20 0...15 4...10 3...8 0...7 0...7 0...15 Read/write
±8 ±13 ±15 ±20 ±6 ±4 ±4 ±7 heads
±8 ±13 ±15 ±20 ±6 ±7 ±5 ±4 ±4 ±7 Data
couplers
±8 ±13 ±15 ±20 ±6 ±7 ±5 ±4 ±4 ±7
Read only
±8 ±13 ±15 ±20 ±6 ±6 ±3 ±2 ±4 ±7 compact
±8 ±13 ±8 ±6 ±15 ±20 ±6 ±6 ±3 ±7 processors
Processors
±8 ±13 ±8 ±6 ±15 ±10 ±10 ±20 ±15 ±8 ±6 ±5 ±7
easy loop®
±8 ±13 ±8 ±6 ±15 ±10 ±10 ±20 ±15 ±8 ±6 ±7 Communi-
±13 ±0 ±0 ±15 ±10 ±8 ±20 ±15 ±6 ±6 ±7 cation module
±13 ±15 ±0 ±0 ±20 ±10 ±0 Standard
handheld
±13 ±15 ±20 ±0 Access
±15 ±20 protection
±20
±20

M12×1
Sensing
face

Cable length 500 mm

■ www.balluff.com 205
BIS L Industrial RFID System
Read/write heads

For limited space, even on metal


Small read heads with processor electronics for glass data carriers

Dimensions
Housing material
For standard processor Ordering code
Part number
For BIS V processor Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection to
Connection cable

For use with BIS L-150-05/A


F Ordering code
Appropriate data carrier Part number
Distance Mounting
Offset
Write distance in mm
Read distance in mm
Offset in mm at distance 0 mm
Offset
10 mm
15 mm
20 mm
25 mm

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

206
BIS L Industrial RFID System
Read/write heads

26×40×12 mm
Aluminum, anodized and ABS
BIS0051
BIS L-350-S115
BIS00UK
BIS VL-350-001-S4

0...+70 °C (minus temperatures on request)


–20...+85 °C
IP 67
125 kHz LF
Processor
See page 274/280 for cable options BIS L Industrial
RFID System
Range of
BIS003N applications
BIS L-150-05/A Read/write
distances
overview
0...17 0...24 0...24 Data carriers
0...17 0...24 0...24 read/write
±18 ±20 ±20 Data carriers
read only
±18 ±20 ±20 Read/write
±10 ±20 ±20 heads
±14 ±14 Data
couplers
±14 ±14
Read only
compact
processors
Processors
easy loop®
Data Communi-
carrier cation module
Sensing position
face Standard
handheld
Access
protection

Cable length 500 mm

■ www.balluff.com 207
BIS L Industrial RFID System
Data couplers

For maximum flexibility from pallet to pallet –


with 2-way air interface

Dimensions M30×1.5
Housing material Brass, coated
Base coupler for read/write head Ordering code BIS00K1
Part number BIS L-380-ST/10
Data coupler for data carrier Ordering code
Part number
Data coupler for data carrier Ordering code
Part number
Mounting
Operating temperature 0...+70 °C
Storage temperature –20...+85 °C
Degree of protection per IEC 60529 IP 67
Connection type M12 connector male, 4-pin
For use with BIS L-300-S115

Ordering code
Appropriate data carrier Part number

For installation pay attention to Basic Information chapter.


Sensing
face
Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

Sensing face
Sensing face
A L Read/write heads
BIS L-300 Cable
BIS L-50.
read head

Processor
for

BIS L-60..

Data couplers
BIS L-380-.../BU-PU1-.. BIS L-380-ST/10
B
Data carriers
BIS L-1.., BIS L-2..

208
BIS L Industrial RFID System
Data couplers

M18×1 25×50×10 mm M30×1.5


Brass, coated ABS Brass, coated

BIS00JT BIS00JW BIS00JZ


BIS L-380-02/BU-PU1-00,15 BIS L-380-05/BU-PU1-00,15 BIS L-380-10/BU-PU1-00,5
BIS00JU BIS00JY
BIS L-380-02/BU-PU1-00,5 BIS L-380-05/BU-PU1-00,5

0...+70 °C 0...+70 °C 0...+70 °C


125 kHz LF
–20...+85 °C –20...+85 °C –20...+85 °C
IP 67 IP 67 IP 67 BIS L Industrial
RFID System
M12 connector female, 4-pin M12 connector female, 4-pin M12 connector female, 4-pin Range of
BIS L-380-ST/10 BIS L-380-ST/10 BIS L-380-ST/10 applications
Read/write
distances
BIS003E BIS003E BISL101 overview
BIS L-103-05/L BIS L-103-05/L BIS L-101-01/L Data carriers
read/write
Data carriers
Sensing Sensing Sensing read only
face face face Read/write
heads
Data
couplers
Read only
compact
processors
Processors
easy loop®
Communi-
cation module
Standard
handheld
Access
protection

Distance A Distance A Distance A

Distance B Distance B Distance B

■ www.balluff.com 209
BIS L Industrial RFID System
Read only compact processors
Parallel

For applications with no controller:


for direct activation of actuators, switches, etc.
Parallel signals for easier integration. The processors are compact,
handy and very easy to install and the recessed antennas, which
are available in different designs, make them ideal for a wide variety
of different applications. These simple processors can also be used
in dynamic processes: the data from the data carrier last accessed
is stored in the cache until retrieved again. The data is available for
longer and programming is simplified as a result. Different antenna
characteristics and data carriers are used dependin on application
requirements. The selection does not depend on the interface being Description, Dimensions
used – only the design is a decisive factor. The BIS L-2_ _-03/L are Housing material
read-only data carriers with a fixed 5-byte (40 bits) „unique number“. Parallel Ordering code
No repetition of the unique number or delivery of sequential numbers Part number
is possible – other options are available here. These data carrier Parallel with CRC check Ordering code
types are used with BIS L-405-033-... processors. Part number
Sensor base 5 m cable Ordering code
Secure is secure: CRC test Part number
The CRC-16 check sum can be used for applications with higher 10 m cable Ordering code
demands for data integrity. A check sum that allows the validity Part number
of data to be checked anywhere and at any time is stored on the 15 m cable Ordering code
data carrier. Discrepancies are diagnosed immediately. The Part number
BIS L-405-037-... processor checks the correctness of the read data 20 m cable Ordering code
using a CRC-16 check sum. The CRC value is calculated automati- Part number
cally using the data in bytes 0, 1 and 2 of the data carrier. Stored in Mounting
bytes 3 and 4 of the data carrier, this CRC 16 check sum guarantees Supply voltage, Ripple
an extremely high degree of data integrity without requiring additional Current
programming work. In order to use the CRC-16 check sum, the Operating temperature
type BIS L-10_-05/L data carriers must first be initialized using a Degree of protection per IEC 60529
BIS L-60_ _ processor and BISCOMRW.EXE software. 3 bytes are Connection type
available for the user data. Control I/O
Connection base (please order separately)
The BIS L-405-037-... processor can only be operated using
initialized type BIS L-10_-05/L data carriers.

Appropriate data carrier


Mounting
Read distance in mm
Offset in mm at distance 0 mm
5 mm
8 mm
10 mm
15 mm
20 mm
25 mm
30 mm
35 mm
40 mm
45 mm

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round
210
BIS L Industrial RFID System
Read only compact processors

LED function
fu
indicators included
indicato

Module 40×41×120 mm Connection


PBT PBT
BIS00CM
BIS L-405-033-001-05-MU
BIS00CT
BIS L-405-037-001-05-MU
BCC00R2
BIS L-503-PU1-05
BCC00R3
BIS L-503-PU1-10
125 kHz LF
BCC00R4
BIS L-503-PU1-15 BIS L Industrial
RFID System
BCC00R5
Range of
BIS L-503-PU1-20 applications
Read/write
distances
24 V DC +10 %/–20 %, ≤ 10 % overview
≤ 50 mA no load Data carriers
0...+70 °C 0...+70 °C read/write
IP 67 (when assembled) IP 67 (when assembled) Data carriers
read only
Requires mounting base Read/write
2 inputs, 10 outputs heads
BIS L-503-PU1-_ _ Data
couplers
Read only
compact
BIS L-100-05/L-RO

BIS L-101-05/L-RO

BIS L-102-05/L-RO

BIS L-103-05/L-RO

processors
Processors
BIS L-200-03/L

BIS L-201-03/L

BIS L-202-03/L

BIS L-203-03/L

easy loop®
Communi-
BIS003W
BIS003U

BIS003C
BIS003R

cation module
BIS003T

BIS003F
BIS0035

BIS0038

Standard
handheld
Access
protection

0...30 0...40 0...55 0...20


±15 ±20 ±30 ±10
±15 ±20 ±30 ±10
±15 ±20 ±30 ±10
±15 ±20 ±30 ±10
±15 ±20 ±30 ±10
±15 ±20 ±30
±15 ±20 ±30
±20 ±30
±20 ±30
±30
±30

Sensing
face

■ www.balluff.com 211
BIS L Industrial RFID System
Read only compact processors
Parallel

For applications with no controller:


for direct activation of actuators, switches, etc.

LED function
indicators
included

Description,Dimensions Module M18×1


Housing material PBT and brass, coated
Parallel Ordering code BIS00CN
Part number BIS L-405-033-002-05-MU
Parallel with CRC check Ordering code BIS00CU
Part number BIS L-405-037-002-05-MU
Sensor base 5 m cable Ordering code
Part number
10 m cable Ordering code
Part number
15 m cable Ordering code
Part number
20 m cable Ordering code
Part number
Mounting
Supply voltage, Ripple 24 V DC +10 %/–20 %, ≤ 10 %
Current ≤ 50 mA no load
Operating temperature 0...+70 °C
Degree of protection per IEC 60529 IP 67 (when assembled)
Connection type Requires mounting base
Control I/O
Connection base (please order separately) BIS L-503-PU1-_ _
BIS L-100-05/L-RO

BIS L-101-05/L-RO

BIS L-103-05/L-RO
BIS L-200-03/L

BIS L-201-03/L

BIS L-203-03/L
BIS003W
BIS003R

BIS003T

BIS003F
BIS0035

BIS0038

Appropriate data carrier


Mounting
Read distance in mm 0...23 0...27 0...16
Offset in mm at distance 0 mm ±12 ±15 ±8
5 mm ±12 ±15 ±8
8 mm ±12 ±15 ±8
10 mm ±12 ±15 ±8
15 mm ±12 ±15 ±4
20 mm ±15
25 mm ±6

For installation pay attention to Basic Information chapter.


Sensing
Mounting: face

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

212
BIS L Industrial RFID System
Read only compact processors

LED function LED function


indicators indicators
included included

Module M12×1 Module 25×50×10 mm Connection


PBT and brass, coated PBT and ABS PBT
BIS00CP BIS00CR
BIS L-405-033-003-05-MU BIS L-405-033-004-05-MU
BIS00CW BIS00CY
BIS L-405-037-003-05-MU BIS L-405-037-004-05-MU
BCC00R2
BIS L-503-PU1-05
BCC00R3
BIS L-503-PU1-10
125 kHz LF
BCC00R4
BIS L-503-PU1-15 BIS L Industrial
RFID System
BCC00R5
Range of
BIS L-503-PU1-20 applications
Read/write
distances
24 V DC +10 %/–20 %, ≤ 10 % 24 V DC +10 %/–20 %, ≤ 10 % overview
≤ 50 mA no load ≤ 50 mA no load Data carriers
0...+70 °C 0...+70 °C 0...+70 °C read/write
IP 67 (when assembled) IP 67 (when assembled) IP 67 (when assembled) Data carriers
read only
Requires mounting base Requires mounting base Read/write
2 inputs, 10 outputs heads
BIS L-503-PU1-_ _ BIS L-503-PU1-_ _ Data
couplers
Read only
compact
BIS L-103-05/L-RO

BIS L-100-05/L-RO

BIS L-101-05/L-RO

BIS L-103-05/L-RO

processors
Processors
BIS L-203-03/L

BIS L-200-03/L

BIS L-201-03/L

BIS L-203-03/L

easy loop®
Communi-
BIS003W

BIS003W
BIS003R

cation module
BIS003T
BIS003F

BIS003F
BIS0035

BIS0038

Standard
handheld
Access
protection

0...11 0...23 0...27 0...16


±6 ±12 ±15 ±8
±6 ±12 ±15 ±8
±4 ±12 ±15 ±8
±2 ±12 ±15 ±8
±12 ±15 ±4
±8 ±15
±6

Sensing Sensing
face face

■ www.balluff.com 213
BIS L Industrial RFID System
Read only compact processors
Serial

For simple connection


to the controller: readable
data carriers only
Easy ID solutions are not
only available with a parallel
interface, but also with a serial
interface, which is why they are
suitable for smart, single-celled LED function
indicators
production platforms. Balluff included
offers different point-to-point
connections specific to each Dimensions 40×41×120 mm
device. The range extends Housing material PBT
from interfaces such as RS232, Serial, RS232 Ordering code BIS00C5
RS422 to IO-Link. A "daisy Part number BIS L-400-035-001-00-S115
chain" configuration with RS232 Serial, RS422 Ordering code BIS00C6
or Ethernet TCP/IP is also pos- Part number BIS L-400-035-001-02-S115
sible. Systems with or without Mounting
recessed antennas are available Supply voltage, Ripple 24 V DC +10 %/–20 %, ≤ 10 %
to allow a flexible response to Current ≤ 50 mA
different installation situations Operating temperature 0...+70 °C
such as cramped spaces, for Degree of protection per IEC 60529 IP 67
example. Connection type M12 connector male, 8-pin
These simple processors can Connection cable See page 281 for cable options
also be used in dynamic pro-
cesses: the data from the data

BIS L-100-05/L-RO

BIS L-101-05/L-RO

BIS L-102-05/L-RO

BIS L-103-05/L-RO
carrier last accessed is stored in

BIS L-200-03/L

BIS L-201-03/L

BIS L-202-03/L

BIS L-203-03/L
the cache until retrieved again.
The data is available for longer

BIS003W
BIS003U

BIS003C
BIS003R

BIS003T

BIS003F
BIS0035

BIS0038
and programming is simplified
as a result. A distinction is made
between use of the type Appropriate data carrier
BIS L-2_ _-03/L data carrier Mounting
and the programmed data Read distance in mm 0...30 0...40 0...55 0...20
carrier with type Offset in mm at distance 0 mm ±15 ±20 ±30 ±10
BIS L-10_-05/L CRC check. 5 mm ±15 ±20 ±30 ±10
The processors must be para- 8 mm ±15 ±20 ±30 ±10
meterized accordingly using the 10 mm ±15 ±20 ±30 ±10
relevant configuration software. 15 mm ±15 ±20 ±30 ±10
Different antenna characte- 20 mm ±15 ±20 ±30
ristics and data carriers are 25 mm ±15 ±20 ±30
used depending on application 30 mm ±4 ±20 ±30
requirements. 35 mm ±20 ±30
40 mm ±30
The selection does not depend 45 mm ±30
on the interface being used – 50 mm ±6
only the design is a decisive
factor. For installation pay attention to Basic Information chapter.

Mounting: Sensing
BIS L at a glance face
■ Tough flush in steel
■ Compact
non-flush on steel
■ Read only
■ Simple to integrate non-metal

Antenna type:

rod

round

214
BIS L Industrial RFID System
Read only compact processors

LED function LED function LED function


indicators indicators indicators
included included included

M18×1
18×1 M12×1
12×1 25×50×10
5 50 10 mm
PBT and brass, coated PBT and brass, coated PBT and ABS
BIS00C7 BIS00C9 BIS00CC
BIS L-400-035-002-00-S115 BIS L-400-035-003-00-S115 BIS L-400-035-004-00-S115
BIS00C8 BIS00CA
BIS L-400-035-002-02-S115 BIS L-400-035-003-02-S115

24 V DC +10 %/–20 %, ≤ 10 % 24 V DC ±10 %/–20 %, ≤ 10 % 24 V DC ±10 %/–20 %, ≤ 10 %


≤ 50 mA no load ≤ 50 mA no load ≤ 50 mA no load
0...+70 °C 0...+70 °C 0...+70 °C
125 kHz LF
IP 67 IP 67 IP 67
M12 connector male, 8-pin M12 connector male, 8-pin M12 connector male, 8-pin BIS L Industrial
RFID System
See page 281 for cable options See page 281 for cable options See page 281 for cable options
Range of
applications
Read/write
BIS L-100-05/L-RO

BIS L-101-05/L-RO

BIS L-103-05/L-RO

BIS L-103-05/L-RO

BIS L-100-05/L-RO

BIS L-101-05/L-RO

BIS L-103-05/L-RO
distances
overview
BIS L-200-03/L

BIS L-201-03/L

BIS L-203-03/L

BIS L-203-03/L

BIS L-200-03/L

BIS L-201-03/L

BIS L-203-03/L
Data carriers
read/write
BIS003W

BIS003W

BIS003W
Data carriers
BIS003R

BIS003R
BIS003T

BIS003T
BIS003F

BIS003F

BIS003F
BIS0035

BIS0038

BIS0035

BIS0038
read only
Read/write
heads
Data
couplers
0...23 0...27 0...16 0...11 0...23 0...27 0...16 Read only
compact
±12 ±15 ±8 ±6 ±12 ±15 ±8 processors
±12 ±15 ±8 ±6 ±12 ±15 ±8 Processors
±12 ±15 ±8 ±8 ±12 ±15 ±8 easy loop®
±12 ±15 ±8 ±2 ±12 ±15 ±8 Communi-
cation module
±12 ±15 ±4 ±12 ±15 ±4 Standard
±12 ±15 ±8 ±15 handheld
±6 ±6 Access
protection

Sensing Sensing Sensing


face face face

Cable length Cable length Cable length


500 mm 500 mm 500 mm

■ www.balluff.com 215
BIS L Industrial RFID System
Read only compact processors with IO-Link interface
IO-Link

Easy ID solutions are not only


available with a parallel interface,
but also with a serial interface,
which is why they are suitable for
smart, single-celled production
platforms. Balluff offers different
point-to-point connections spe-
cific to each device. The range LED function
indicators
extends from interfaces such included
as RS232, RS422 to IO-Link.
A "daisy chain" configuration Dimensions 40×41×120 mm
with RS232 or Ethernet TCP/IP Housing material PBT
is also possible. Systems with IO-Link, 8 byte Ordering code BIS00CZ
or without recessed antennas Part number BIS L-409-045-001-07-S4
are available to allow a flexible Mounting
response to different installation Supply voltage, Ripple 24 V DC +10 %/–20 %, ≤ 10 %
situations such as cramped Current ≤ 150 mA
spaces, for example. Operating temperature 0...+70 °C
Degree of Protection per IEC 60529 IP 67
These simple processors can Connection type M12 connector male, 4-pin
also be used in dynamic pro- Connection cable See page 274 for cable options
cesses: the data from the data
carrier last accessed is stored in

BIS L-100-05/L-RO

BIS L-101-05/L-RO

BIS L-102-05/L-RO

BIS L-103-05/L-RO
the cache until retrieved again.

BIS L-200-03/L

BIS L-201-03/L

BIS L-202-03/L

BIS L-203-03/L
The data is available for longer
and programming is simplified

BIS003W
BIS003U

BIS003C
BIS003R

BIS003T

BIS003F
BIS0035

BIS0038
as a result. A distinction is made
between use of the type
BIS L-2_ _-03/L data carrier and Appropriate data carrier
the programmed data carrier Mounting
with type BIS L-10_-05/L CRC Read distance in mm 0...25 0...35 0...48 0...16
check. The processors must Offset in mm at distance 0 mm ±15 ±20 ±25 ±10
be parameterized accordingly 3 mm ±15 ±20 ±25 ±10
using the relevant configuration 4 mm ±15 ±20 ±25 ±10
software. Different antenna cha- 5 mm ±15 ±20 ±25 ±10
racteristics and data carriers are 7 mm ±15 ±20 ±25 ±10
used depending on application 8 mm ±15 ±20 ±25 ±10
requirements. 10 mm ±15 ±20 ±25 ±10
12 mm ±15 ±20 ±25 ±10
The selection does not depend 15 mm ±15 ±20 ±25 ±10
on the interface being used – 20 mm ±15 ±20 ±25
only the design is a decisive 25 mm ±8 ±20 ±25
factor. 30 mm ±20 ±25
35 mm ±20 ±25
BIS L at a glance 40 mm ±25
■ Tough 45 mm ±25
■ Compact
■ Read only IO-Link Version 1.1
■ Simple to integrate Max. cycle time 8.8 ms
IO-Link process data length 8 input bytes/8 output bytes
Communication indicators Green LED, pulsing

For installation pay attention to Basic Information chapter.


Sensing
Mounting: face

flush in steel

non-flush on steel

non-metal

Antenna type:
For information on other IO-Link
and networking products, refer to rod
our "Industrial Networking and
Connectivity" catalog or visit us
online at www.balluff.com round

216
BIS L Industrial RFID System
Read only compact processors with IO-Link interface

LED function LED function LED function


indicators indicators indicators
included included included

M18×1 M12×1 25×50×10 mm


PBT and brass, coated PBT and brass, coated PBT and ABS
BIS00E0 BIS00E1 BIS00E2
BIS L-409-045-002-07-S4 BIS L-409-045-003-07-S4 BIS L-409-045-004-07-S4

24 V DC +10 %/–20 %, ≤ 10 % 24 V DC ±10 %/–20 %, ≤ 10 % 24 V DC ±10 %/–20 %, ≤ 10 %


≤ 150 mA ≤ 150 mA no load ≤ 150 mA no load
0...+70 °C 0...+70 °C 0...+70 °C
IP 67 IP 67 IP 67
M12 connector male, 4-pin M12 connector male, 4-pin M12 connector male, 4-pin
125 kHz LF
See page 274 for cable options See page 274 for cable options See page 274 for cable options
BIS L Industrial
RFID System
Range of
BIS L-100-05/L-RO

BIS L-101-05/L-RO

BIS L-103-05/L-RO

BIS L-103-05/L-RO

BIS L-100-05/L-RO

BIS L-101-05/L-RO

BIS L-103-05/L-RO
applications
BIS L-200-03/L

BIS L-201-03/L

BIS L-203-03/L

BIS L-203-03/L

BIS L-200-03/L

BIS L-201-03/L

BIS L-203-03/L
Read/write
distances
overview
BIS003W

BIS003W

BIS003W
BIS003R

BIS003R
BIS003T

BIS003T
BIS003F

BIS003F

BIS003F
BIS0035

BIS0038

BIS0035

BIS0038
Data carriers
read/write
Data carriers
read only
Read/write
heads
0...15 0...18 0...10 0...7 0...15 0...18 0...10 Data
±10 ±12 ±4 ±4 ±10 ±12 ±4 couplers
±10 ±12 ±4 ±4 ±10 ±12 ±4 Read only
compact
±10 ±12 ±4 ±4 ±10 ±12 ±4 processors
±10 ±12 ±4 ±4 ±10 ±12 ±4 Processors
±10 ±12 ±4 ±10 ±12 ±4 easy loop®
±10 ±12 ±4 ±10 ±12 ±4 Communi-
cation module
±10 ±12 ±4 ±10 ±12 ±4 Standard
±12 ±12 handheld
±12 ±12 Access
protection

8.8 ms 8.8 ms 8.8 ms


8 input bytes/8 output bytes 8 input bytes/8 output bytes 8 input bytes/8 output bytes
Green LED, pulsing Green LED, pulsing Green LED, pulsing

Sensing Sensing Sensing


face face face

Cable length Cable length Cable length


500 mm 500 mm 500 mm

■ www.balluff.com 217
BIS L Industrial RFID System
Read only compact processors with easy loop ®
easy loop®

Easy ID solutions are not only


available with a parallel interface,
but also with a serial interface,
which is why they are suitable for
smart, single-celled production
platforms. Balluff offers different
point-to-point connections spe-
cific to each device. LED function
indicators
included
The range extends from interfa-
ces such as RS232, RS422 to Dimensions 40×41×120 mm
IO-Link. A "daisy chain" confi- Housing material PBT
guration with RS232 or Ethernet RS422, easy loop® Ordering code BIS00CH
TCP/IP is also possible. Systems Part number BIS L-400-043-001-02-S115
with or without recessed Mounting
antennas are available to allow Supply voltage, Ripple 24 V DC +10 %/–20 %, ≤ 10 %
a flexible response to different Current ≤ 50 mA
installation situations such as Operating temperature 0...+70 °C
cramped spaces, for example. Degree of protection per IEC 60529 IP 67
Connection type M12 connector male, 8-pin
These simple processors can Connection cable See page 280 for cable options
also be used in dynamic pro-
cesses: the data from the data

BIS L-100-05/L-RO

BIS L-101-05/L-RO

BIS L-102-05/L-RO

BIS L-103-05/L-RO
carrier last accessed is stored in

BIS L-200-03/L

BIS L-201-03/L

BIS L-202-03/L

BIS L-203-03/L
the cache until retrieved again.
The data is available for longer

BIS003W
BIS003U

BIS003C
BIS003R

BIS003T

BIS003F
BIS0035

BIS0038
and programming is simplified as
a result.
Appropriate data carrier
A distinction is made between Mounting
use of the type BIS L-2_ _-03/L Read distance in mm 0...30 0...40 0...55 0...20
data carrier and the programmed Offset in mm at distance 0 mm ±15 ±20 ±30 ±10
data carrier with type 3 mm ±15 ±20 ±30 ±10
BIS L-10_-05/L CRC check. 4 mm ±15 ±20 ±30 ±10
The processors must be para- 5 mm ±15 ±20 ±30 ±10
meterized accordingly using the 7 mm ±15 ±20 ±30 ±10
relevant configuration software. 8 mm ±15 ±20 ±30 ±10
Different antenna characte- 10 mm ±15 ±20 ±30 ±10
ristics and data carriers are 12 mm ±15 ±20 ±30 ±10
used depending on application 15 mm ±15 ±20 ±30 ±10
requirements. 20 mm ±15 ±20 ±30
25 mm ±15 ±20 ±30
The selection does not depend 30 mm ±20 ±30
on the interface being used – 35 mm ±20 ±30
only the design is a decisive 40 mm ±30
factor. 45 mm ±30
50 mm ±6
BIS L at a glance
■ Tough For installation pay attention to Basic Information chapter.
■ Compact
Sensing
■ Read only Mounting:
face
■ Simple to integrate flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

218
BIS L Industrial RFID System
Read only compact processors with easy loop®

LED function LED function LED function


indicators indicators indicators
included included included

M18 M12 25×50×10 mm


PBT and brass, coated PBT and brass, coated PBT and ABS
BIS00CJ BIS00CK BIS00CL
BIS L-400-043-002-02-S115 BIS L-400-043-003-02-S115 BIS L-400-043-004-02-S115

24 V DC +10 %/–20 %, ≤ 10 % 24 V DC ±10 %/–20 %, ≤ 10 % 24 V DC ±10 %/–20 %, ≤ 10 %


≤ 50 mA ≤ 50 mA no load ≤ 50 mA no load
0...+70 °C 0...+70 °C 0...+70 °C
IP 67 IP 67 IP 67
M12 connector male, 8-pin M12 connector male, 8-pin M12 connector male, 8-pin
125 kHz LF
See page 280 for cable options See page 280 for cable options See page 280 for cable options
BIS L Industrial
RFID System
Range of
BIS L-100-05/L-RO

BIS L-101-05/L-RO

BIS L-103-05/L-RO

BIS L-103-05/L-RO

BIS L-100-05/L-RO

BIS L-101-05/L-RO

BIS L-103-05/L-RO
applications
BIS L-200-03/L

BIS L-201-03/L

BIS L-203-03/L

BIS L-203-03/L

BIS L-200-03/L

BIS L-201-03/L

BIS L-203-03/L
Read/write
distances
overview
BIS003W

BIS003W

BIS003W
BIS003R

BIS003R
BIS003T

BIS003T
BIS003F

BIS003F

BIS003F
BIS0035

BIS0038

BIS0035

BIS0038
Data carriers
read/write
Data carriers
read only
Read/write
heads
0...23 0...27 0...16 0...11 0...27 0...16 Data
±12 ±15 ±8 ±6 ±12 ±15 ±8 couplers
±12 ±15 ±8 ±6 ±12 ±15 ±8 Read only
compact
±12 ±15 ±8 ±6 ±12 ±15 ±8 processors
±12 ±15 ±8 ±4 ±12 ±15 ±8 Processors
±12 ±15 ±8 ±4 ±12 ±15 ±8 easy loop®
±12 ±15 ±8 ±4 ±12 ±15 ±8 Communi-
cation module
±12 ±15 ±8 ±2 ±12 ±15 ±8 Standard
±12 ±15 ±4 ±12 ±15 ±4 handheld
±12 ±15 ±4 ±12 ±15 ±4 Access
protection
±12 ±15 ±8 ±15
±6 ±6

Sensing Sensing Sensing


face face face

Cable length Cable length Cable length


500 mm 500 mm 500 mm

■ www.balluff.com 219
BIS L Industrial RFID System
Serial RS232 processors
Serial RS232

Cost-effective identification –
operate 2 read/write heads simultaneously
■ Sequential reading of the data carrier ID number
on both read/write heads
■ Service-friendly, all parameter data are stored in
an interchangeable memory
■ Accepts all read/write heads
■ Interface-compatible with BIS C, BIS S and BIS M
identification systems

Easy integration in all controllers Description
The compact class BIS L-600_ with its reduced dimensions and Housing material
various interface options can be used wherever ambient conditions Serial RS232 Ordering code
require higher protection. The devices are ideal for IP 65 and appli- Part number
cations involving media that is not aggressive to PS plastic. Small, Supply voltage, Ripple
compact, flexible and economical Current
Operating temperature
The ruggedized version BIS L-602_ is in spite of the mechanically Storage temperature
rugged die-cast aluminum housing a small, flexible processor which Degree of protection per IEC 60529
is available with various interface options. Suitable for all applications Read/write head ports
with demanding requirements for mechanical rigidity and chemical Connection for
resistance. Connection type
Accessories included
Connection cable

220
BIS L Industrial RFID System
Serial RS232 processors

Processor Processor
ABS Aluminum cast, coated
BIS00E3 BIS00E8
BIS L-6000-007-050-00-ST15 BIS L-6020-007-050-00-ST15
24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 %
≤ 400 mA ≤ 400 mA
0...+60 °C 0...+60 °C
0...+60 °C 0...+60 °C
IP 65 IP 65
2× external 2× external
125 kHz LF
2× read/write heads BIS L-3_ _ 2× read/write heads BIS L-3_ _
2× M12 connector male, 5-pin 2× M12 connector male, 5-pin BIS L Industrial
RFID System
Configuration software Configuration software
Range of
See page 282/287 for cable options See page 282/287 for cable options applications
Read/write
distances
overview
Data carriers
read/write
Data carriers
read only
Read/write
heads
Data
couplers
Read only
compact
processors
Processors
easy loop®
Communi-
cation module
Standard
handheld
Access
protection

■ www.balluff.com 221
BIS L Industrial RFID System
Profibus processors

Cost-effective identification –
operate 2 read/write heads simultaneously
■ Selectable division of the data width on the Profibus, 4...128 bytes
■ Free assigning of the data width for each read/write head
■ Optimum data speed, internal cycle time is shorter than
the bus activation time
■ Service-friendly, all parameter data are stored in an
interchangeable memory
■ BUS address selectable with switches
■ Accepts all read/write heads
■ Interface-compatible with BIS C and BIS M identification systems Description
Housing material
The compact class BIS L-600_ with its reduced dimensions and Profibus Ordering code
various interface options can be used wherever ambient conditions Part number
require higher protection. The devices are ideal for IP 65 and appli- Supply voltage, Ripple
cations involving media that is not aggressive to PS plastic. Small, Current
compact, flexible and economical. Operating temperature
Storage temperature
The ruggedized version BIS L-602_ is in spite of the mechanically Degree of protection per IEC 60529
rugged die-cast aluminum housing a small, flexible processor which Read/write head ports
is available with various interface options. Suitable for all applications Service interface
with demanding requirements for mechanical rigidity and chemical Connection for
resistance. Connection type

Accessories included
Connection cable

222
BIS L Industrial RFID System
Profibus processors

Processor Processor
ABS Aluminum cast, coated
BIS00E6 BIS00EC
BIS L-6002-019-050-03-ST11 BIS L-6022-019-050-03-ST14
24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 %
≤ 400 mA ≤ 400 mA
0...+60 °C 0...+60 °C
0...+60 °C 0...+60 °C
IP 65 IP 65
2× external 2× external
125 kHz LF
RS232 RS232
2× read/write heads BIS L-3_ _ 2× read/write heads BIS L-3_ _ BIS L Industrial
RFID System
1× M12 connector male, 5-pin, B-coded 1× M12 connector male, 5-pin, B-coded
Range of
1× M12 connector female, 5-pin, B-coded 1× M12 connector female, 5-pin, B-coded applications
1× M12 connector male, 5-pin 2× M12 connector male, 5-pin Read/write
distances
Software GSD-file Software GSD-file overview
See page 282/290/305 for cable options See page 282/290/305 for cable options Data carriers
read/write
Data carriers
read only
Read/write
heads
Data
couplers
Read only
compact
processors
Processors
easy loop®
Communi-
cation module
Standard
handheld
Access
protection

Recommended accessories 9
06Z
(please order separately) BCC

5
071
BCC

14
Ordering code BAM0114 C07
BC
Part number BKS 12-CS-01
Threaded cover for M12 connector

■ www.balluff.com 223
BIS L Industrial RFID System
Devicenet processors

Cost-effective identification –
operate 2 read/write heads simultaneously
■ Freely selectable buffer size between 0 and 256 bytes
■ Service-friendly, all parameter data are stored
in an interchangeable memory
■ Accepts all read/write heads
■ Interface-compatible with BIS C and BIS M identification systems

The compact class BIS L-600_ with its reduced dimensions and
various interface options can be used wherever ambient conditions
require higher protection. The devices are ideal for IP 65 and appli- Description
cations involving media that is not aggressive to PS plastic. Small, Housing material
compact, flexible and economical. Devicenet Ordering code
Part number
The ruggedized version BIS L-60_ _ is in spite of the mechanically Supply voltage, Ripple
rugged die-cast aluminum housing a small, flexible processor which Current
is available with various interface options. Suitable for all applications Operating temperature
with demanding requirements for mechanical rigidity and chemical Storage temperature
resistance. Degree of protection per IEC 60529
Read/write head ports
Service interface
Connection for
Connection type

Accessories included
Connection cable

224
BIS L Industrial RFID System
Devicenet processors

Processor Processor
ABS Aluminum cast, coated
BIS00E7 BIS00EE
BIS L-6003-025-050-03-ST12 BIS L-6023-025-050-03-ST13
24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 %
≤ 600 mA ≤ 600 mA
0...+60 °C 0...+60 °C
0...+60 °C 0...+60 °C
IP 65 IP 65
2× external 2× external
125 kHz LF
RS232 RS232
2× read/write heads BIS L-3_ _ 2× read/write heads BIS L-3_ _ BIS L Industrial
RFID System
2× M12 connector male, 5-pin 2× M12 connector male, 5-pin
Range of
1× M12 connector female, 5-pin 1× 7/8" connector male, 5-pin applications
1× 7/8“ connector female, 5-pin Read/write
distances
Software EDS-file Software EDS-file overview
See page 282/296/305 for cable options See page 284/294/305 for cable options Data carriers
read/write
Data carriers
read only
Read/write
heads
Data
couplers
Read only
compact
processors
Processors
easy loop®
Communi-
cation module
Standard
handheld
Access
protection

06Z9
BCC

070K
BCC

070F
BCC

0A09
BCC

■ www.balluff.com 225
BIS L Industrial RFID System
Ethernet/IP processor

Cost-effective identification –
operate 2 read/write heads simultaneously.

Description Processor
Housing material Aluminum cast, coated
Ethernet/IP Ordering code BIS00EF
Part number BIS L-6026-034-050-06-ST19
Supply voltage, Ripple 24 V DC ±20 %, ≤ 10 %
Current ≤ 400 mA
Operating temperature 0...+60 °C
Storage temperature 0...+60 °C
Degree of protection per IEC 60529 IP 65
Read/write head ports 2× external
Service interface RS232
Connection for Read/write heads BIS L-3_ _
Connection type 1× M12 connector female, 4-pin, D-coded
1× M12 connector male, 5-pin
1× M12 connector male, 4-pin
Accessories included Configuration software
Connection cable See page 286/292/305 for cable options

226
Ethernet BIS L Industrial RFID System
Ethernet TCP/IP processor
TCP/IP
Operate 2 read/write
heads sequentially.

Description Processor
Housing material Aluminum cast, coated
Ethernet TCP/IP Ordering code BIS00EH
Part number BIS L-6027-039-050-06-ST19
Supply voltage, Ripple 24 V DC ±20 %, ≤ 10 %
Current ≤ 400 mA
Operating temperature 0...+60 °C
Storage temperature 0...+60 °C
Degree of protection per IEC 60529 IP 65
Read/write head ports 2× external
125 kHz LF
Service interface RS232
Connection for Read/write heads BIS L-3_ _ BIS L Industrial
RFID System
Connection type 1× M12 connector female, 4-pin, D-coded
Range of
1× M12 connector male, 5-pin applications
1× M12 connector male, 4-pin Read/write
distances
Accessories included Configuration software overview
Connection cable See page 286/292/305 for cable options Data carriers
read/write
Data carriers
read only
Read/write
heads
Data
couplers
Read only
compact
processors
Processors
easy loop®
Communi-
cation module
Standard
handheld
Access
protection

Suitable connectors
(please order separately)

Ordering code BCC0C5J


Part number BIS C-526-PU-00,6
Order accessories separately! Adapter cable for Ethernet
from M12, D-coded to coupling RJ45 see connectivity section.

■ www.balluff.com 227
BIS L Industrial RFID System
BIS V processors – new generation

A new generation system for more flexible RFID:


Combine up to four low and high frequency read/write heads
with I/O in one device.
The BIS V Radio Frequency Identification (RFID) system is founded
on a new generation of RFID processors that maximize your flexibility
by providing a single device for both low frequency 125Khz and high
frequency 13.56Mhz read/write heads with an IO-Link master port.
Combining up to four heads on either frequency with local analog,
valve manifold or I/O access/control provides a solution you can ap-
ply to many types of RFID applications.This can save cost and time
using a single processor platform across your application installation Description
base. The BIS V system also allows you to draw on a single proces- Housing material
sor family with a wide array of read/write head and RFID tag options Profibus Ordering code
for both manufacturing and logistics solutions. Part number
EtherCAT Ordering code
The BIS V RFID system offers a higher level of performance than Part number
other systems to solve today’s industrial applications. Designed to CC-Link Ordering code
maximize performance while improving usability out on the line, the Part number
BIS V processor provides a functional display and LED’s making sta- Supply voltage, Ripple
tus and setup easier. And a USB service interface makes connection Current
for setup to today’s PC’s simple. The BIS V offers these additional Operating temperature
functions: Storage temperature
■ Four asynchronous 125Khz and 13.56Mhz read/write Protection per IEC 60529
antenna channels. Read/write head ports
■ LCD display with control buttons for setting and displaying Service interface
the Profibus address and data carrier/tags UID. Control inputs / outputs
■ An integrated IO-Link master port for connecting discrete Connection for
or analog I/O, or valve manifolds. Connection type
■ Intelligent power plug option for saving parameters on the device.
■ Industrial IP rated metal housing for any application environment.
■ Flexible mounting options for hard-point or DIN rail.

Accessories included
Connection cable

The following communication options will become available in 2013:


Ethernet/IP, CC-Link, Profinet, and Ethernet TCP/IP

The compact EMC-protected metal housing with small dimensions


(170×60×40 mm) is perfectly integrated and simple to mount. In control
cabinets or in the field up to IP 65, on a top-hat rail, or on a profile.

Increment/ Decrement/
Cancel control button Enter control button

Display

Status LEDs

Read/write head Read/write head


connection 1 connection 2

The industrial RFID system BIS V was developed and qualified according
to the principles of GAMP® 5. You can obtain more detailed information upon
request at rfidpharma@balluff.com
Read/write head Read/write head
connection 3 connection 4

USB and IO-Link


connection
7/8" power plug

Bus out Bus in

228
BIS L Industrial RFID System
BIS V processors – new generation

Profibus processor EtherCAT processor CC-Link processor


Aluminum cast, coated Aluminum cast, coated Aluminum cast, coated
BIS00T3
BIS V-6102-019-C001
BIS00U9
BIS V-6110-063-C002
BIS010P
BIS V-6111-073-C003
24V DC ±10% LPS Class 2, ≤ 10% 24V DC ±10% LPS Class 2, ≤ 10% 24V DC ±10% LPS Class 2, ≤ 10%
≤ 2 A ≤ 2 A ≤ 2 A
125 kHz LF
0...+60 °C 0...+60 °C 0...+60 °C
0...+60 °C 0...+60 °C 0...+60 °C BIS L Industrial
RFID System
IP 65 IP 65 IP 65
Range of
4× external 4× external 4× external applications
IO-Link 1.1, USB 2.0 IO-Link 1.1, USB 2.0 IO-Link 1.1, USB 2.0 Read/write
distances
IO-Link based IO-Link based IO-Link based overview
4 Read/write head BIS VM-3_ _ _ 4 Read/write head BIS VM-3_ _ _ 4 Read/write head BIS VM-3_ _ _ Data carriers
4× M12 connector female, 5-pin 4× M12 connector female, 5-pin 4× M12 connector female, 5-pin read/write
1× 7/8" connector male, 5-pin 1× 7/8“ connector male, 5-pin 1× 7/8“ connector male, 5-pin Data carriers
read only
1× M12 connector male, 5-pin 2× M12 connector female, 4-pin 1× M12 connector male, 5-pin Read/write
1× M12 connector female, 5-pin 1× M12 connector female, 3-pin 1× M12 connector female, 5-pin heads
1× M12 connector female, 3-pin 1× M12 connector female, 3-pin Data
couplers
Configuration software Configuration software Configuration software
Read only
See page 274/279/290/306 for cable options See page 274/279/290/306 for cable options See page 274/279/290/306 for cable options compact
processors
Processors
easy loop®
Communi-
cation module
Standard
handheld
Access
protection

■ www.balluff.com 229
BIS L Industrial RFID System
Communication module for easy loop ®
easy loop®

For simple installation


Use easy loop® to extend the
BIS L system at minimal cost:
compact read heads and the
communication module for simple
connection to the controller.
Prefabricated cable and connec-
tors for rapid, correct wiring.
No address settings.

Install the BIS L simply by con-


necting a maximum of eight read
heads with easy loop® interface
to two lines. A single cable
will suffice and a separate power
supply is no longer necessary.

All processor units function inde-


pendently to allow dynamic ope- Maximum of 8 processor
units on each line.
ration: Data is transferred reliably All lines can be extended
when the data carrier passes by. up to 80 m!

Terminator
BCC00TM
BKS-S117-RO1

Tee
BCC00TK
BKS-S115-TW2-03

Connection cables
BIS Z-501-PU-_ _

Line 1 Line 2

Communication
module RS232 or
Ethernet

230
BIS L Industrial RFID System
Communication module for easy loop®

Description Comm
Communication
nication inte
interface
fac
Housing material ABS
Serial RS232 Ordering code BAE003W
Part number BIS Z-EL-002-RS232
Ethernet TCP/IP Ordering code BAE003U
Part number BIS Z-EL-001-Ethernet
Supply voltage, Ripple 24 V DC ±20 %, ≤ 10 %
Current ≤ 200 mA (+20 mA for each connected processor unit)
Operating temperature 0...+60 °C
Storage temperature 0...+60 °C
125 kHz LF
Degree of protection per IEC 60529 IP 65
Read/write head ports 2× external BIS L Industrial
RFID System
Connection for Line 1 and 2 (2× M12 connector female, 8-pin)
Range of
Connection type 1× M12 connector male, 5-pin applications
1× M12 connector male, 5-pin, A-coded (RS232) Read/write
distances
or M12 connector female, 4-pin, D-coded (TCP/IP) overview
Connection cable See page 280/305/293 for cable options Data carriers
read/write
Data carriers
read only

9.5
Read/write
heads
Data
couplers
Read only
compact
processors
Processors
easy loop®
Communi-
cation module
Standard
handheld
Access
protection
20.5

RS232 version shown

Suitable connectors
(please order separately)

Description Tee Terminator Operating voltage Ethernet connector RS232 connector Ethernet adapter
Ordering code BCC00TK BCC00TM BCC06Z9 BCC03WZ BCC00PM BCC0C5J
Part number BKS-S115-TW2-03 BKS-S117-RO1 BCC M435-0000-1A-000-41X475-000 BCC M474-0000-2D-000-51X475-000 BIS C-522-PVC-02 BIS C-526-PU-00,6

■ www.balluff.com 231
BIS L Industrial RFID System
Standard handheld

For enhanced operating convenience


Allows portable writing and reading of BIS L data carriers.
Easy operation thanks to
■ Touchscreen with large color Windows CE® display and
■ Pre-installed Balluff software and keyboard or stylus.

Ideal for poor light conditions and challenging environments. Data


transfer via optional WLAN, Bluetooth or wired USB. The Handheld
is also modular for expandability.

Additional convenience Antenna type


Function
A pistol grip is provided for ergonomic comfort.
Housing material
Standard base Ordering code
Part number
Standard + WLAN module Ordering code
Part number
Standard + 1D code reader Ordering code
Part number
Standard + 2D code reader Ordering code
Part number
Standard + ID code reader + WLAN Ordering code
Part number
Standard +2D code reader + WLAN Ordering code
Part number
Keyboard
Display
Supply voltage
Capacity
Interface
Working temperature
Degree of protection per IEC 60529
Read/write head option
Accessories included
Appropriate data carrier

Please order additional accessories separately

Standard handheld BIS L-87_-1-008-X-000_


includes charger and stylus.

Antenna type:

rod

round

Recommended accessories
(please order separately)

Description Pistol grip option Optional docking station


with power supply
Ordering code FHW0004 FHW0003
Part number 11023836 11023834

232
BIS L Industrial RFID System
Standard handheld

General purpose Rod Tool ID


Read/write Read/write Read/write
ABS ABS ABS
BAE00A2 BAE00CN BAE00CH
BIS L-870-1-008-X-000 BIS L-871-1-008-X-000 BIS L-873-1-008-X-000
BAE00K4 BAE00EJ
BIS L-870-1-008-X-001 BIS L-871-1-008-X-001 BIS L-873-1-008-X-001

BIS L-870-1-008-X-002 BIS L-871-1-008-X-002 BIS L-873-1-008-X-002


125 kHz LF
BIS L-870-1-008-X-003 BIS L-871-1-008-X-003 BIS L-873-1-008-X-003
BAE00EA BAE00EA BIS L Industrial
RFID System
BIS L-870-1-008-X-004 BIS L-871-1-008-X-004 BIS L-873-1-008-X-004
Range of
applications
BIS L-870-1-008-X-005 BIS L-871-1-008-X-005 BIS L-873-1-008-X-005 Read/write
distances
52 buttons, alphanumeric 52 buttons, alphanumeric 52 buttons, alphanumeric overview
TFT Touchscreen display TFT Touchscreen display TFT Touchscreen display Data carriers
3.7 V rechargeable battery pack 3.7 V rechargeable battery pack 3.7 V rechargeable battery pack read/write
4000 mA/h 4000 mA/h 4000 mA/h Data carriers
read only
RS232/Balluff Dialog RS232/Balluff Dialog RS232/Balluff Dialog Read/write
–10...+50 °C –10...+50 °C –10...+50 °C heads
IP 65 IP 65 IP 65 Data
couplers
Integrated Integrated Integrated
Read only
Charging power supply and stylus Charging power supply and stylus Charging power supply and stylus compact
for BIS L-Data carrier for BIS L-Data carrier for BIS L-Data carrier processors
Processors
with round coil Ø ≥ 35 mm with rod antenna with round coil Ø ≤ 34 mm
easy loop®
Docking station and Pistol Grip Docking station and pistol Grip Docking station and pistol grip Communi-
cation module
51 51 100 51
Standard
100 100
handheld
Ø14.5 Access
protection
20
265

265

265

■ www.balluff.com 233
BIS L Industrial RFID System
Access protection

Access protection
And here's how it works: Individual access codes are allocated
via programmable data keys, which can then be disabled to prevent
further programming.
Unauthorized personnel cannot manipulate the data key as
a result. The data key is read via an antenna fitted to a special
bracket. The processor unit then issues the data.
Different interfaces such as serial, Profibus, Devicenet, Ethernet/IP
or parallel interfaces enable simple connection to the monitored
system. Available for systems BIS C, BIS L and BIS M.
Version
The benefits to you Use
Simple upgrade and rapid replacement without modifying the Housing material
system software. End users are independent of system providers. Ordering code
The access system is easy to integrate in read/write stations that Part number
already use an identification system. Simply connect the access Operating temperature
monitoring antenna to the second channel on the existing processor Storage temperature
unit. Hardware expenses are reduced to a minimum and software Protection per IEC 60529
only requires slight modification in order to process both channels.

234
BIS L Industrial RFID System
Access protection

Access protection Data carrier and bracket Tag Holder


Attachment for read/write head BIS M-304 Used with BIS Z-ZA-001 Used with BIS L-103 and BIS L-203
POM and PA 6.6 POM and PA 12 POM
BAM012N BIS00ZY BAM012H
BIS Z-ZA-001 BIS L-103-05/L-ZC1 BIS L-203-ZH1
0...+70 °C –25...+70 °C –25...+85 °C
–20...+85 °C –25...+85 °C
IP 67 IP 67

Sensing
face
125 kHz LF
BIS L Industrial
RFID System
Range of
applications
Read/write
distances
overview
Data carriers
read/write
Data carriers
read only
Read/write
heads
Data
couplers
Read only
compact
processors
Processors
easy loop®
Communi-
Electronic key for access control. Interchangeable with data carriers BIS L-103 cation module
Easy to implement using the "RFID key". and BIS L-203, easy to mount – even on metal. Standard
The mount and prism clamp secure the data handheld
carrier and prevent it from falling out. Access
protection

Mounting a data carrier

Data Carriers

Data carrier replacement

■ www.balluff.com 235
BIS S
Industrial
RFID
3.65 MHz HF
System
Inductive Identification
Large data volumes for controlling assembly and production. The
BIS S system uses a Dual Frequency 3.65 MHz read and 560 KHz
write inductively coupled technology along with passive tags.

Host
controller
PLC, PC
Profibus
Devicenet

Profibus
Devicenet
Ethernet/IP
Ethernet TCP/IP

Handy Programmer

Interface
variations

Processors

Read/write
heads

Data carriers

236
BIS S Industrial RFID System
Inductive identification

Data carriers read/write 238


Read/write heads 240
Processors 242
Handy programmer 248

3.65 MHz HF

Basic information
and definitions
can be found on
page 352

■ www.balluff.com 237
BIS S Industrial RFID System
Data carriers read/write

Benefit from a large storage capacity

Dimensions
Housing material
Weight

BIS S programmable
8 kBytes Ordering code
Part number
16 kBytes Ordering code
Part number
32 kBytes Ordering code
Part number
Operating temperature
Storage temperature
Degree of protection per IEC 60529

Appropriate read/write head with max. read/write distance


Mounting
BIS S-301
BIS S-302
BIS S-303

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel

non-flush on steel

non-metal

Antenna type:

rod

round

238
BIS S Industrial RFID System
Data carriers read/write

52×32×11 mm 80×40×22 mm
PBTP POM
27 g 93 g

BIS004J
BIS S-108-32/L
BIS004K BIS004N
BIS S-108-42/L BIS S-150-42/A
BIS004L BIS004P
BIS S-108-52/L BIS S-150-52/A
0...+70 °C 0...+70 °C
–20...+85 °C –20...+85 °C
IP 67 IP 67

3.65 MHz HF
BIS S
Industrial
30 mm 50 mm RFID System
20 mm Data carriers
20 mm read/write
Read/write
heads
Sensing Sensing Processors
face face Handy
programmer

■ www.balluff.com 239
BIS S Industrial RFID System
Read/write heads

First choice in static applications


involving large quantities of data.

Dimensions
Housing material
Ordering code
Part number
Mounting
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Connection to
Connection cable

Appropriate data carrier


Mounting
Write distance in mm
Read distance in mm
Offset in mm at distance 5 mm
7 mm
10 mm
15 mm
20 mm
30 mm
50 mm

For installation pay attention to Basic Information chapter.

Mounting:

flush in steel
Example:
non-flush on steel

non-metal

Antenna type:
BIS S-302-S115 rod

round
BIS S-301-S115

BIS Z-501-PU1-_ _ BIS Z-502-PU1-_ _

BKS S117-00

BIS S-6003-... BIS S-6023-...

240
BIS S Industrial RFID System
Read/write heads

40×40×138 mm 40×40×138 mm 80×80×40


80 40 mm
ABS ABS PBT, ABS
BIS005R BIS005T BIS005F
BIS S-302-S115 BIS S-303-S115 BIS S-301-S115

0...+70 °C 0...+70 °C 0...+50 °C


–20...+85 °C –20...+85 °C –20...+85 °C
IP 67 IP 67 IP 67
Processor Processor Processor
See page 280 for cable options See page 280 for cable options See page 280 for cable options

BIS S-150-42/A

BIS S-150-52/A
BIS S-108-32/L

BIS S-108-42/L

BIS S-108-52/L

BIS S-108-32/L

BIS S-108-42/L

BIS S-108-52/L

BIS S-108-32/L

BIS S-108-42/L

BIS S-108-52/L
3.65 MHz HF
BIS004N
BIS004K

BIS004K

BIS004K
BIS004P
BIS004L

BIS004L

BIS004L
BIS004J

BIS004J

BIS004J
BIS S
Industrial
RFID System
Data carriers
read/write
5...20 5...20 10...50 5...30 Read/write
5...20 5...20 10...50 5...30 heads
±5 ±5 ±5 ±5 Processors
Handy
±5 ±5 ±5 ±5 programmer
±5 ±5 ±5 ±5
±5 ±5 ±5 ±5
±5 ±5 ±5 ±5
±5
±5

Sensing face Sensing face Sensing face

■ www.balluff.com 241
BIS S Industrial RFID System
Profibus processors

Cost-effective identification –
operate 2 read/write heads simultaneously
■ Selectable division of the data width on the Profibus,
4...128 bytes
■ Free assigning of the data width for each read/write head
■ Optimum data speed, internal cycle time is shorter than
the bus activation time
■ Service-friendly, all parameter data are stored in an
interchangeable memory
■ Bus address selectable with switches
■ Accepts all read/write heads Description
■ Interface-compatible with BIS C and BIS L identification systems Housing material
Profibus Ordering code
The compact class BIS S-600_ with its reduced dimensions and Part number
various interface options can be used wherever ambient conditions Supply voltage, Ripple
require higher protection. The devices are ideal for IP 65 and appli- Current
cations involving media that is not aggressive to PS plastic. Small, Operating temperature
compact, flexible and economical. Storage temperature
Degree of protection per IEC 60529
The ruggedized version BIS S-602_ is in spite of the mechanically Read/write head ports
rugged die-cast aluminum housing a small, flexible processor which Service interface
is available with various interface options. Suitable for all applications Connection for
with demanding requirements for mechanical stability and chemical Connection type
resistance.

Accessories included
Connection cable

242
BIS S Industrial RFID System
Profibus processors

Processor Processor
ABS Aluminum cast, coated
BIS00F3 BIS00F5
BIS S-6002-019-050-03-ST11 BIS S-6022-019-050-03-ST14
24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 %
≤ 600 mA ≤ 600 mA
0...+60 °C 0...+60 °C
0...+60 °C 0...+60 °C
IP 65, NEMA 12 IP 65, NEMA 12
2× external 2× external
RS232 RS232
2× read/write heads BIS S-30_ 2× read/write heads BIS S-30_
1× M12 connector male, 5-pin, B-coded 1× M12 connector male, 5-pin, B-coded
1× M12 connector female, 5-pin, B-coded 1× M12 connector female, 5-pin, B-coded
1× M12 connector male, 5-pin 2× M12 connector male, 5-pin
3.65 MHz HF
Software GSD file Software GSD file
See page 280/290/305 for cable options See page 280/290/305 for cable options BIS S
Industrial
RFID System
Data carriers
read/write
Read/write
heads
Processors
Handy
programmer

Recommended accessories 06Z


9
BCC
(please order separately)

5
071
BCC

14
Ordering code BAM0114 C07
BC
Part number BKS 12-CS-01
Threaded cover for M12 connector

■ www.balluff.com 243
BIS S Industrial RFID System
Devicenet processors

Cost-effective identification –
operate 2 read/write heads simultaneously
■ Freely selectable buffer size between 0 and 256 bytes
■ Service-friendly, all parameter data are stored in an
interchangeable memory
■ Accepts all read/write heads
■ Interface-compatible with BIS C and BIS L identification systems

The compact class BIS S-600_ with its reduced dimensions and
various interface options can be used wherever ambient conditions
require higher protection. The devices are ideal for IP 65 and appli- Description
cations involving media that is not aggressive to PS plastic. Small, Housing material
compact, flexible and economical. Devicenet Ordering code
Part number
The ruggedized version BIS S-602_ is in spite of the mechanically Supply voltage, Ripple
rugged die-cast aluminum housing a small, flexible processor which Current
is available with various interface options. Suitable for all applications Operating temperature
with demanding requirements for mechanical stability and chemical Storage temperature
resistance. Degree of protection per IEC 60529
Read/write head ports
Service interface
Connection for
Connection type

Accessories included
Connection cable

244
BIS S Industrial RFID System
Devicenet processors

Processor Processor
ABS Aluminum cast, coated
BIS00F4 BIS00F6
BIS S-6003-025-050-03-ST12 BIS S-6023-025-050-03-ST13
24 V DC ±20 %, ≤ 10 % 24 V DC ±20 %, ≤ 10 %
≤ 600 mA ≤ 600 mA
0...+60 °C 0...+60 °C
0...+60 °C 0...+60 °C
IP 65, NEMA 12 IP 65, NEMA 12
2× external 2× external
RS232 RS232
2× read/write heads BIS S-30_ 2× read/write heads BIS S-30_
2× M12 connector male, 5-pin 2× M12 connectors male, 5-pin
1× M12 connector female, 5-pin 1× 7/8" connectors male, 5-pin
1× 7/8" connectors female, 5-pin
3.65 MHz HF
Software EDS file Software EDS file
See page 280/296/305 for cable options See page 280/294/305 for cable options BIS S
Industrial
RFID System
Data carriers
read/write
Read/write
heads
Processors
Handy
programmer

06Z9
BCC

070K
BCC

070F
BCC

0A09
BCC

■ www.balluff.com 245
BIS S Industrial RFID System
Ethernet/IP processors

Description Processor
Housing material Aluminum cast, coated
Ethernet/IP Ordering code BIS00F7
Part number BIS S-6026-034-050-06-ST19
Supply voltage, Ripple 24 V DC ±20 %, ≤ 10 %
Current ≤ 400 mA
Operating temperature 0...+60 °C
Storage temperature 0...+60 °C
Degree of protection per IEC 60529 IP 65
Read/write head ports 2× external
Service interface yes
Connection for 2× read/write heads BIS S-30_
Connection type 1× M12 connector, 4-pin, D-coded
1× M12 connector, 5-pin
1× M12 connector, 4-pin
Accessories included Configuration software
Connection cable See page 280/292/305 for cable options

246
Ethernet BIS S Industrial RFID System
Ethernet TCP/IP processors
TCP/IP

Description Processor
Housing material Aluminum cast, coated
Ethernet TCP/IP Ordering code BIS00F8
Part number BIS S-6027-039-050-06-ST19
Supply voltage, Ripple 24 V DC ±20 %, ≤ 10 %
Current ≤ 400 mA
Operating temperature 0...+60 °C
Storage temperature 0...+60 °C
Degree of protection per IEC 60529 IP 65
Read/write head ports 2× external
Service interface yes
Connection for 2× read/write heads BIS S-30_
Connection type 1× M12 connector, 4-pin, D-coded
1× M12 connector, 5-pin
1× M12 connector, 4-pin
3.65 MHz HF
Accessories included Configuration software
Connection cable See page 280/292/305 for cable options BIS S
Industrial
RFID System
Data carriers
read/write
Read/write
heads
Processors
Handy
programmer

Suitable connectors
(please order separately)

Ordering code BCC0C5J


Part number BIS C-526-PU-00,6
Order accessories separately! Adapter cable for Ethernet
from M12, D-coded to coupling RJ45 see connectivity section.

■ www.balluff.com 247
BIS S Industrial RFID System
Handy programmer

For maximum flexibility


Benefit from increased mobility during repair work. The handy
programmer with read/write function helps you stay mobile and inde-
pendent. The handy programmer is fitted with an interface to a PC.

Function
Dimensions
Housing material
Ordering code
Part number
Keyboard
Display
Current
Capacity
Interface
Operating temperature
Storage temperature
Degree of protection per IEC 60529
Read head connection
Connection to
Accessories

Appropriate data carrier

Antenna type:

rod

round

248
BIS S Industrial RFID System
Handy programmer

Read/write heads Handy programmer


Ø 15×63 mm 232×97×55 mm
Plastic ABS
BAE0098 BAE008M
BIS S-850 BIS S-810-0-003
32 buttons, alphanumeric
LCD-display, 20 characters/4 lines
2.4 V rechargeable battery pack NiMH
1500 mA/h
RS232, Balluff Dialog
0...+40 °C 0...+50 °C
–10...+50 °C
IP 54 IP 40
Fixed plug, 6-pin Fixed socket, 6-pin
BIS S-810 1× M12 connector, 5-pin
3.65 MHz HF
Carrying case included
BIS S
Industrial
RFID System
BIS S-108_ _ Data carriers
BIS S-150_ _ read/write
Read/write
heads
Processors
Handy
programmer
Sensing face

Recommended accessories
(please order separately)

Description C
Charger Rechargeable battery Ch
Charging
i cradle
dl with
ith Ch
Charger
Ordering code BAE0047 125997 BAE0048
Part number BIS C-701-A Akku-BIS C-81. 2,4V 1500 MAH BIS C-702-A
Please order separately!

■ www.balluff.com 249
BVS
Vision
Sensors
Vision-based Identification
The Balluff BVS Vision Sensor is the perfect choice to insure a relia-
ble, flexible and productivity increasing vision-based quality solution.
The BVS offers a full tool box of advanced machine vision functions
that can be combined to reliably solve error proofing, quality che-
cking and bar code reading applications. With the BVS, recognizing
defects on multiple part types early in the production process is
possible using the same sensor. In-process inspection job changing
eliminates sensor arrays and complex costly hardware, increasing
reliability and quality while reducing overall costs.

250
BVS Vision Sensors
Vision-based identification

BVS Vision Sensors – As simple as a sensor 252


BVS-E Vision Sensors Identification 260
BVS-E Vision Sensors Standard 262
BVS-E Vision Sensors Advanced 264
BVS-E Vision Sensors Universal 266
BVS-E Vision Sensor Monitor 268
BAV Balluff Added-Value Kits 269

Basic information
and definitions
can be found on
page 352

■ www.balluff.com 251
BVS Vision Sensors
The best combination of vision sensing
simplicity and functionality

Easy to use
As simple as a sensor

In most production situations, vision systems can be overkill – too Reduces Costs
expensive, too much functionality, and just too complex. Instead, ■ Single-unit operation replaces expensive,
Balluff Vision Sensors are easy to set up, simple to use, and quicker cumbersome multi-sensor solutions
to return your initial investment. ■ Four models with multiple performance levels to choose
from provide multiple price points based on functionality
The BVS Vision Sensor is a powerful error proofing tool that can be ■ Single easy to use software package minimizes setup
used in almost any area of your manufacturing process. It provides time and cuts startup costs
reliable part or feature presence/absence and position detection, ■ Provides vision performance at smart sensor pricing
plus dimension verification and accurate barcode reading with crisp
and reliable resolution. The BVS has far more functionality than any Increases Product Quality
discrete sensor, sensor array, or vision product in its class. ■ Eliminates unreliable manual inspection
■ Allows 100% quality checking instead of audit checking
■ Provides the resolution needed for reliable quality inspection
■ Enables automated barcode reading

Increases Productivity
■ Improves line speed and error proofing by
eliminating the need for manual inspection
■ Minimizes false code reads with very high code resolution
for greater reliability
■ Catches errors sooner to reduce unplanned downtime and scrap
■ Reduces planned downtime with greater functionality and flexibility

252
BVS Vision Sensors
The best combination of vision sensing
simplicity and functionality

BVS Vision
Sensors
Easy to use –
as simple as
a sensor
BVS-E
Ident
BVS-E
Standard
BVS-E
Advanced
BVS-E
Universal
BVS-E
Vision-Sensor
Monitor
BAV Added-
Value-Kits von
Balluff

■ www.balluff.com 253
BVS Vision Sensors
Product overview – The models at a glance

BVS will optimize your inspection process control, regardless There are four different model types available:
of which version you use in your application. Benefits include ■ BVS-E Identification –
greater efficiency and process reliability. Easily and reliably read a large number of codes
■ BVS-E Standard –
Each of these models are available in four different focal lengths, Sensor of choice for simple error proofing tasks
red or infrared light source and two or more digital outputs. ■ BVS-E Advanced –
360° detection of parts for optimized process control
The following provides an overview of the different features ■ BVS-E Universal –
and special functions to help you select the right Vision Sensor versatile tools for demanding quality checking
for your application. and part positioning
■ BVS-E Monitor –
a small and easy to use visualisation accessory
compatible for each BVS-E model

BVS-E Identification BVS-E Standard BVS-E Advanced BVS-E Universal


Features
Tools 3 7 8 14
Features per inspection up to 32 up to 32 up to 255 up to 255
Typical detection rate up to 15 Hz up to 15 Hz up to 40 Hz up to 40 Hz
Connection Single or networked Single or networked Single or networked Single or networked
by PC by PC by PC by PC
Bus interface Ethernet/RS232 Ethernet Ethernet/RS232
Focal length 6 mm ■ ■ ■ ■
8 mm ■ ■ ■ ■
12 mm ■ ■ ■ ■
16 mm ■ ■ ■
Digital outputs 2 (+1 optional) 3 (+1 optional) 3 (+1 optional) 2 (+1 optional)

Main applications Easily and reliably For simple error Optimized for 360° Versatile tools for error
read 1D and 2D Codes proofing and quality detection of parts proofing, code rea-
or verify characters checking tasks and process control ding, process control
and part positioning

The benefits to you ■ 1D codes: ■ Short setup times All of the functions ■ Precisely locate and
detects or reads most and convenient format of the BVS-E Standard, verify your part with
common barcodes change on the PC plus: 360° contour based
■ 2D codes: ■ Flexible adaptation to ■ Logical linking of tools
detects or reads your process by simply tools to the outputs ■ Position and proces-
Data Matrix codes activating the relevant ■ Efficient hardware sing results available
■ Verifies characters inspections via for higher processing via RS232 or TCP/IP
■ Process results via the PLC control rates ■ One versatile sensor
RS232 or TCP/IP ■ Simultaneous checking ■ 360° position with all functions
of multiple features detection

From page 260 262 264 266

254
BVS Vision Sensors
Tool overview

All variants include a mix of features. Define your application needs

BVS-E Identification
and select the right version according to its features. The BVS offers

BVS-E Advanced
BVS-E Universal
BVS-E Standard
the best solutions in its product class for every application.

Check brightness
■ Identify different types and parts
■ Check illumination brightness ■ ■ ■
■ Detect the function of a display
Compare contrast
■ Monitor presence of labels
■ Detect a label ■ ■ ■
■ Check completeness
Count edges
■ Monitor the number of pins on ICs
■ Check threads for completeness ■ ■ ■
■ Monitor the quality of gear wheels
Compare width
■ Check for presence (e.g. lids)
■ Differentiate parts ■ ■ ■
■ Monitor location and orientation
Detect pattern
■ Check parts quality
■ Differentiate types ■ ■ ■ ■

Check contour
■ Check for absence of burrs and flashing BVS Vision
■ Differential parts shapes ■ ■ Sensors
Easy to use –
as simple as
Monitor position a sensor
■ Monitor level BVS-E
Ident
■ Position parts and products ■ ■ ■
BVS-E
■ Position labels Standard
BVS-E
360° defect finder Advanced
■ Quality check on parts BVS-E
■ Completeness check of parts ■ Universal
BVS-E
■ Nominal/Actual comparison Vision-Sensor
Monitor
360° contour count
BAV Added-
■ Verify correct number of parts Value-Kits von
■ Presence absence of parts (e.g. screws) ■ Balluff
■ Filling control (e.g. blisters)
360° contour match
■ Robot control (via Ethernet interface)
■ Align parts independent from background ■

Compare character (OCV)


■ Check labels
■ Monitor printing (e.g. ensure correct dates for different lots) ■ ■
■ Check logos
360° position detection
■ Align parts
■ Robot control (via Ethernet interface) ■ ■
■ Inspection irrespective of the position
Detect and identify barcode and Data Matrix code
■ Code verification
■ Documentation of parts used ■ ■
■ Verify characters

■ www.balluff.com 255
BVS Vision Sensors
BVS ConVis Vision Sensor software

One software package – whichever BVS you use


The ConVis software detects the connected BVS vision sensor auto-
matically. You can use the software to simulate all sensor models
and establish whether an alternative sensor model is compatible with
your application. The software guides you, step-by-step, through
your sensor setup. The onscreen setup guide offers additional help
for each step if you need it.

BVS-E Identification BVS-E Standard

BVS-E Identification BVS-E Standard


This version allows you to detect and read all standard codes avai- The standard version of the Vision Sensor software has the following
lable on the market. Barcodes or Data Matrix codes within the field features: 20 inspection memory slots, free rotation of tools and a
of view are read and inspected and/or output via the serial interface, zoom function. You have the choice of seven independent tools.
depending on the settings. The large number of codes that the Needless to say, free software updates are included and existing
sensor can recognize allows you to use devices capable of reading sensors can be updated easily.
varying code types.

Detecting and reading barcodes Detecting location


Barcodes are a way of uniquely identifying products during the In the feeder on an oscillating conveyor, screws are provided for
manufacturing process. The BVS-E Identification incorporates two assembly. With the BVS you prevent problems, since incorrectly
modes: 1. a taught-in barcode is inspected and an OK/NOK signal located screws or different screw types are immediately detected
is output. 2. any code is read and output via the serial interface. and shunted out.

256
BVS Vision Sensors
BVS ConVis Vision Sensor software

BVS-E Advanced BVS-E Universal

Logical connections
AND
OR
Exclusive OR
NOT AND
NOT OR
NOT Exclusive OR
NOT
Majority selector
BVS-E Advanced BVS-E Universal
The BVS-E Advanced offers all the features of the standard version The application range of the BVS Universal includes part presence
in addition to 360° position detection and logical linking. These checks, reading and verifying codes to demanding part positioning BVS Vision
Sensors
features allow the combination of a maximum of 255 tools as well applications. The new powerful 360° contour match tools allow for
Easy to use –
as full utilization of up to four digital outputs. the locating, verifying and counting of rotated parts in your applica- as simple as
a sensor
tion. The detected part location can then be transmitted to a PLC
BVS-E
or Robot using the built in communication interface. Ident
BVS-E
Standard
BVS-E
Advanced
BVS-E
Universal
BVS-E
Vision-Sensor
Monitor
BAV Added-
Value-Kits von
Balluff

Checking for completeness Check contour


After manual assembly, the completeness of a product is checked. Injection molded parts need to be checked at the inspection
Three flexibly configurable outputs allow you for example to monitor station: Defective parts or parts with flashing are shunted out
the completeness of each series or special features. for special rework.

■ www.balluff.com 257
BVS Vision Sensors
Applications – Process reliability for automation

Checking blister filling


Tablet blisters are inspected after
the automated filling process as
a form of quality assurance mea-
sure. Check whether each nest
is filled and the correct prepa-
ration is inserted. Reconfigurati-
ons, even in-process, are always
possible. So you always remain
flexible. Monitor your production
using the BVS with absolute
reliability.

Checking for presence Check labeling and correct positioning


V-belt pulleys are attached using four nuts. The Vision Sensor Quality assurance requires that cans are checked for correct printing
checks the presence of all nuts at any one time, simultaneously in any position. The 360 degree Contour match locates the can
and independently of the alignment position. and also checks the print. It can be combined with other tool the
BVS offers, so some could check if barcodes are readable or if the
lables are correct. The position of the label can be found and sent
via RS232 or Ethernet to a PLC or robot.

258
BVS Vision Sensors
Applications – Process reliability for automation

Checking bottle caps Detecting and reading Data Matrix codes


To seal bottles perfectly, the cap needs to be seated correctly. Leave Data Matrix codes are used in industrial environments. This BVS
the inspection to our Vision Sensor. It checks positions absolutely tool also incorporates two modes: 1. a taught-in Data Matrix code
reliably and reduces scrap while simultaneously increasing producti- is inspected and an OK/NOK signal is output. 2. any code is read
vity. When formats are changed, reconfigurations are even possible and output via the serial interface so that you always know what is
in-process. happening during the production process.

BVS Vision
Sensors
Easy to use –
as simple as
a sensor
BVS-E
Ident
BVS-E
Standard
BVS-E
Advanced
BVS-E
Universal
BVS-E
Vision-Sensor
Monitor
BAV Added-
Value-Kits von
Balluff

Verify position
Each package requires a label. But sometimes the label is located
in the wrong place. With the BVS Vision Sensor you check exactly
whether the label is present and whether it is properly applied.

■ www.balluff.com 259
BVS-E Vision Sensors Identification
Detecting and identifying varied codes

Check the marking on your products. Regardless of whether you


label them with 1D codes (barcodes) or 2D codes (Data Matrix
codes), the BVS reads all common codes on the market. Text and
sequences of numbers such as code plain text can be verified using
OCV. The result: "Inspection OK" or "Inspection not OK".
If you need to view the read code data to find out which parts
are being processed, you can output it via the RS232 or Ethernet
interface.

■ Simple operation
■ Read several codes in an inspection simultaneously Series
■ Output code data via RS232 or Ethernet interface Style
■ Verify character strings Lens, focal length
■ Change between inspections via PLC Red light PNP Ordering code
■ Codes read in any position Part number
■ Extensive range of accessories Infrared light PNP Ordering code
■ Function module for PLC available Part number
Supply voltage UB
Switching inputs
Switching outputs
Interface
Rated operating current Ie
Configuration interface
Parameter configuration
Typ. detection rate

Image sensor
Working range
Working distance,
Field of view (horizontal×vertical)
Lighting
Eye safety per IEC 62471
Dimensions
Connection
Degree of protection per IEC 60529
Ambient temperature range Ta
Readable barcodes
Refer to the chapter Basic Information and Definitions on page 378
■ Interleaved 2-of-5 for optical and electrical information. To define the field of view and working
■ Code 39 distance, use the distance calculator at: www.balluff.de/vision
■ Code 128
Refer to the Accessories chapter for a wide variety of external
■ Pharmacode illuminators on page 332, mounting brackets on page 326, and
■ Codabar a selection of compatible connectors on page 308.
■ EAN 8
■ EAN 13
■ UPC-E
■ UPC-A
■ PDF 417

Readable Data Matrix codes


■ ECC 200
(suitable for high and low
contrast, for directly marked
and mirrored codes)

260
BVS-E Vision Sensors Identification
Detecting and identifying varied codes

Vision sensor Vision sensor Vision sensor


BVS-E Identification BVS-E Identification BVS-E Identification
Wide-angle lens, 6 mm Standard lens, 8 mm Telephoto lens, 12 mm
BVS001R BVS0001 BVS000T
BVS ID-3-005-E BVS ID-3-001-E BVS ID-3-003-E
BVS001C BVS0019 BVS001A
BVS ID-3-105-E BVS ID-3-101-E BVS ID-3-103-E
24 V DC ±10 % 24 V DC ±10 % 24 V DC ±10 %
1× Trigger 1× Trigger 1× Trigger
1× lighting synchron., 2× PNP 1× lighting synchron., 2× PNP 1× lighting synchron., 2× PNP
RS232, Ethernet TCP/IP RS232, Ethernet TCP/IP RS232, Ethernet TCP/IP
100 mA 100 mA 100 mA
Ethernet 10/100 Base T Ethernet 10/100 Base T Ethernet 10/100 Base T
ConVis for Windows ConVis for Windows ConVis for Windows
3...40 Hz (depending 3...40 Hz (depending 3...40 Hz (depending
on evaluation function) on evaluation function) on evaluation function)
CMOS-SW-VGA 640×480 CMOS-SW-VGA 640×480 CMOS-SW-VGA 640×480
50...1000 mm 50...1000 mm 50...1000 mm
50 mm, 1000 mm, 50 mm, 1000 mm, 50 mm, 1000 mm,
34×25 mm 676×507 mm 24×18 mm 480×360 mm 16×12 mm 320×240 mm
LED, incident light, deselectable LED, incident light, deselectable LED, incident light, deselectable
Extempt group Extempt group Extempt group BVS Vision
58×52×40 mm 58×52×40 mm 58×52×40 mm Sensors
Easy to use –
2× M12 connector, 8- and 4-pin 2× M12 connector, 8- and 4-pin 2× M12 connector, 8- and 4-pin as simple as
IP 54 IP 54 IP 54 a sensor
–10...+55 °C –10...+55 °C –10...+55 °C BVS-E
Ident
BVS-E
Standard
BVS-E
Advanced
BVS-E
Universal
BVS-E
Vision-Sensor
Monitor
BAV Added-
Value-Kits von
Balluff

50 mm 150 mm 500 mm 1000 mm

Working distance, 6 mm Wide-angle lens 34×25 mm 101×76 mm 338×253 mm 676×507 mm


Field of view 8 mm Standard lens 24×18 mm 72×54 mm 240×180 mm 480×360 mm
(horizontal×vertical) 12 mm Telephoto lens 16×12 mm 48×36 mm 160×120 mm 320×240 mm

* Working range 180 to 1000 mm

■ www.balluff.com 261
BVS-E Vision Sensors Standard
For increased quality and productivity

Inspect and monitor your production process with the BVS-E


Standard. Choose the correct tool for your application from a large
selection and set up your inspection. You can replace several
sensors with a combination of tools. If different components are
used, activate the relevant inspection via the PLC control to allow
production to continue seamlessly without requiring a teach-in/setup
process.

■ Simple operation
■ Convenient setup
■ Reliable evaluation Series
■ Extensive range of accessories Style
■ Function module for PLC available Lens, focal length
Red light PNP Ordering code
Part number
NPN Ordering code
Part number
Infrared light PNP Ordering code
Part number
Supply voltage UB
Switching inputs
Switching outputs

Rated operating current Ie


Configuration interface
Parameter configuration
Typ. detection rate

Image sensor
Software Working range
■ 20 inspection memory cells Working distance,
■ Free rotation of tools Field of view (horizontal×vertical)
■ Zoom function Lighting
■ Existing sensors updated at no extra cost Eye safety per IEC 62471
■ Seven independent tools Connection

Degree of protection per IEC 60529


Ambient temperature range Ta

Refer to the chapter Basic Information and Definitions on page 378


for optical and electrical information. To define the field of view and working
distance, use the distance calculator at: www.balluff.de/vision

Refer to the Accessories chapter for a wide variety of external


illuminators on page 332, mounting brackets on page 326, and
a selection of compatible connectors on page 308.

262
BVS-E Vision Sensors Standard
For increased quality and productivity

Vision sensor Vision sensor Vision sensor


BVS-E Standard BVS-E Standard BVS-E Standard
Wide-angle lens, 6 mm Standard lens, 8 mm Telephoto lens, 12 mm
BVS000E BVS0003 BVS0005
BVS OI-3-005-E BVS OI-3-001-E BVS OI-3-003-E
BVS000C BVS0004 BVS0006
BVS OI-3-006-E BVS OI-3-002-E BVS OI-3-004-E
BVS0013 BVS0014 BVS0012
BVS OI-3-105-E BVS OI-3-101-E BVS OI-3-103-E
24 V DC ±10 % 24 V DC ±10 % 24 V DC ±10 %
1× Trigger, 1× Select 1× Trigger, 1× Select 1× Trigger, 1× Select
1× lighting synchron. or 1× PNP, 1× lighting synchron. or 1× PNP, 1× lighting synchron. or 1× PNP,
3× PNP or NPN configurable 3× PNP or NPN configurable 3× PNP or NPN configurable
100 mA 100 mA 100 mA
Ethernet 10/100 Base T Ethernet 10/100 Base T Ethernet 10/100 Base T
ConVis for Windows ConVis for Windows ConVis for Windows
3...15 Hz (depending 3...15 Hz (depending 3...15 Hz (depending
on evaluation function) on evaluation function) on evaluation function)
CMOS-SW-VGA 640×480 CMOS-SW-VGA 640×480 CMOS-SW-VGA 640×480
50...1000 mm 50...1000 mm 50...1000 mm
50 mm, 1000 mm, 50 mm, 1000 mm, 50 mm, 1000 mm,
34×25 mm 676×507 mm 24×18 mm 480×360 mm 16×12 mm 320×240 mm BVS Vision
LED, incident light, deselectable LED, incident light, deselectable LED, incident light, deselectable Sensors
Easy to use –
Extempt group Extempt group Extempt group as simple as
2× M12 connector, 2× M12 connector, 2× M12 connector, a sensor
8- and 4-pin 8- and 4-pin 8- and 4-pin BVS-E
Ident
IP 54 IP 54 IP 54
BVS-E
–10...+55 °C –10...+55 °C –10...+55 °C Standard
BVS-E
Advanced
BVS-E
Universal
BVS-E
Vision-Sensor
Monitor
BAV Added-
Value-Kits von
Balluff

50 mm 150 mm 500 mm 1000 mm

Working distance, 6 mm Wide-angle lens 34×25 mm 101×76 mm 338×253 mm 676×507 mm


Field of view 8 mm Standard lens 24×18 mm 72×54 mm 240×180 mm 480×360 mm
(horizontal×vertical) 12 mm Telephoto lens 16×12 mm 48×36 mm 160×120 mm 320×240 mm

* Working range 180 to 1000 mm

■ www.balluff.com 263
BVS-E Vision Sensors Advanced
360° detection for optimized process control

In addition to the standard functions of the BVS-E, the advanced


vision sensor also monitors the rotational position. It can detect
objects regardless of the location and position. Production can be
monitored more efficiently through shorter process times and the
option of using logical functions to combine individual checks.

■ 360° position tracking


■ Faster processor reduces process times
■ Features linked by logical functions
■ Extensive range of accessories
■ Function module for PLC available Series
Style
Lens, focal length
Logical connections Red light PNP Ordering code
Part number
NPN Ordering code
Part number
Infrared light PNP Ordering code
Part number
Supply voltage UB
Switching inputs
Switching outputs

Interface
Rated operating current Ie
Configuration interface
AND Parameter configuration
OR
Exclusive OR Typ. detection rate
NOT AND Image sensor
NOT OR
NOT Exclusive OR Working range
NOT Working distance,
Majority selector
Field of view (horizontal×vertical)
Lighting
Refer to the chapter Basic Information and Definitions on page 378 Eye safety per IEC 62471
for optical and electrical information. To define the field of view and working
distance, use the distance calculator at: www.balluff.de/vision Dimensions
Connection
Refer to the Accessories chapter for a wide variety of external Degree of protection per IEC 60529
illuminators on page 332, mounting brackets on page 326, and
a selection of compatible connectors on page 308. Ambient temperature range Ta

264
BVS-E Vision Sensors Advanced
360° detection for optimized process control

Vision sensor Vision sensor Vision sensor


BVS-E Advanced BVS-E Advanced BVS-E Advanced
Wide-angle lens, 6 mm Standard lens, 8 mm Telephoto lens, 12 mm
BVS000L BVS000J BVS000K
BVS OI-3-055-E BVS OI-3-051-E BVS OI-3-053-E
BVS000R BVS000P BVS000N
BVS OI-3-056-E BVS OI-3-052-E BVS OI-3-054-E
BVS0016 BVS0015 BVS0017
BVS OI-3-155-E BVS OI-3-151-E BVS OI-3-153-E
24 V DC ±10 % 24 V DC ±10 % 24 V DC ±10 %
1× Trigger, 1× Select 1× Trigger, 1× Select 1× Trigger, 1× Select
1× lighting synchron. or 1× PNP, 1× lighting synchron. or 1× PNP, 1× lighting synchron. or 1× PNP,
3× PNP or NPN configurable 3× PNP or NPN configurable 3× PNP or NPN configurable
Ethernet TCP/IP Ethernet TCP/IP Ethernet TCP/IP
100 mA 100 mA 100 mA
Ethernet 10/100 Base T Ethernet 10/100 Base T Ethernet 10/100 Base T
ConVis for Windows ConVis for Windows ConVis for Windows
3...50 Hz (depending on evaluation function) 3...50 Hz (depending on evaluation function) 3...50 Hz (depending on evaluation function)
CMOS-SW-VGA 640×480 CMOS-SW-VGA 640×480 CMOS-SW-VGA 640×480
50...1000 mm 50...1000 mm 50...1000 mm
50 mm, 1000 mm, 50 mm, 1000 mm, 50 mm, 1000 mm,
34×25 mm 676×507 mm 24×18 mm 480×360 mm 16×12 mm 320×240 mm BVS Vision
LED, incident light, deselectable LED, incident light, deselectable LED, incident light, deselectable Sensors
Easy to use –
Extempt group Extempt group Extempt group as simple as
58×52×40 mm 58×52×40 mm 58×52×40 mm a sensor
2× M12 connector, 8- and 4-pin 2× M12 connector, 8- and 4-pin 2× M12 connector, 8- and 4-pin BVS-E
Ident
IP 54 IP 54 IP 54
BVS-E
–10...+55 °C –10...+55 °C –10...+55 °C Standard
BVS-E
Advanced
BVS-E
Universal
BVS-E
Vision-Sensor
Monitor
BAV Added-
Value-Kits von
Balluff

50 mm 150 mm 500 mm 1000 mm

Working distance, 6 mm Wide-angle lens 34×25 mm 101×76 mm 338×253 mm 676×507 mm


Field of view 8 mm Standard lens 24×18 mm 72×54 mm 240×180 mm 480×360 mm
(horizontal×vertical) 12 mm Telephoto lens 16×12 mm 48×36 mm 160×120 mm 320×240 mm

* Working range 180 to 1000 mm

■ www.balluff.com 265
BVS-E Vision Sensors Universal
The highest versatility

■ the most versatile functionality – lowers user stock requirements.


■ Contour based analysis – precisely locate and verify your part
■ Ethernet TCP/IP, RS232 interface – part position and checking
results for more process information
■ Fast code location and verification – reliably identify your parts at
higher part rates.

The application range of the BVS Universal includes part presence


checks, reading and verifying codes to demanding part positioning
applications.
Series
The new powerful 360° contour match tools allow for the locating, Style
verifying and counting of rotated parts in your application. The detec- Lens, focal length
ted part location can then be transmitted to a PLC or Robot using Red light PNP Ordering code
the built in communication interface. Part number
Infrared light PNP Ordering code
Up to 40 linear and Data Matrix codes per second can be reliably Part number
located and verified, providing outstanding performance for this class Supply voltage UB
of vision sensor. Switching inputs
Switching outputs
Interface
Rated operating current Ie
Configuration interface
Parameter configuration
Typ. detection rate
Image sensor
Working range
Working distance,
Field of view (horizontal×vertical)
Lighting
Eye safety per IEC 62471
Connection
Degree of protection per IEC 60529
Ambient temperature range Ta

Refer to the chapter Basic Informa-


tion and Definitions on page 378
for optical and electrical information.
To define the field of view and working
distance, use the distance calculator
at: www.balluff.de/vision

Refer to the Accessories chapter for


a wide variety of external illuminators
on page 332, mounting brackets
on page 326, and a selection of
compatible connectors on page 308.

266
BVS-E Vision Sensors Universal
The highest versatility

Vision sensor Vision sensor Vision sensor


BVS-E Universal BVS-E Universal BVS-E Universal
Wide-angle lens, 6 mm Standard lens, 8 mm Telephoto lens, 12 mm
BVS001L BVS001M BVS001N
BVS UR-3-005-E BVS UR-3-001-E BVS UR-3-003-E
BVS001F BVS001H BVS001J
BVS UR-3-105-E BVS UR-3-101-E BVS UR-3-103-E
24 V DC ±10 % 24 V DC ±10 % 24 V DC ±10 %
1× Trigger 1× Trigger 1× Trigger
1× lighting synchron. or 1× PNP, 2× PNP 1× lighting synchron. or 1× PNP, 2× PNP 1× lighting synchron. or 1× PNP, 2× PNP
RS232, Ethernet TCP/IP RS232, Ethernet TCP/IP RS232, Ethernet TCP/IP
100 mA 100 mA 100 mA
Ethernet 10/100 Base T Ethernet 10/100 Base T Ethernet 10/100 Base T
ConVis for Windows ConVis for Windows ConVis for Windows
3...40 Hz (depending on evaluation function) 3...40 Hz (depending on evaluation function) 3...40 Hz (depending on evaluation function)
CMOS-SW-VGA 640×480 CMOS-SW-VGA 640×480 CMOS-SW-VGA 640×480
50...1000 mm 50...1000 mm 50...1000 mm
50 mm, 1000 mm, 50 mm, 1000 mm, 50 mm, 1000 mm,
34×25 mm 676×507 mm 24×18 mm 480×360 mm 16×12 mm 320×240 mm
LED, incident light, deselectable LED, incident light, deselectable LED, incident light, deselectable
Extempt group Extempt group Extempt group
2× M12 connector, 8- and 4-pin 2× M12 connector, 8- and 4-pin 2× M12 connector, 8- and 4-pin BVS Vision
IP 54 IP 54 IP 54 Sensors
Easy to use –
–10...+55 °C –10...+55 °C –10...+55 °C as simple as
a sensor
BVS-E
Ident
BVS-E
Standard
BVS-E
Advanced
BVS-E
Universal
BVS-E
Vision-Sensor
Monitor
BAV Added-
Value-Kits von
Balluff

50 mm 150 mm 500 mm 1000 mm

Working distance, 6 mm Wide-angle lens 34×25 mm 101×76 mm 338×253 mm 676×507 mm


Field of view 8 mm Standard lens 24×18 mm 72×54 mm 240×180 mm 480×360 mm
(horizontal×vertical) 12 mm Telephoto lens 16×12 mm 48×36 mm 160×120 mm 320×240 mm

* Working range 180 to 1000 mm

■ www.balluff.com 267
BVS-E Vision Sensor Monitor
See what the sensor sees

■ Simple, self-explanatory operation


■ Can be retrofitted on all existing sensors
■ Clearly arranged presentation of process
statistics and sensor results
■ Access for operators, setters and administrators
can be controlled by passwords
■ Memory for 20 inspections
■ Connection to sensor via direct link
or network (TCP/IP)

Do you want to see what the sensor sees? You wish to increase your Model Vision Sensor Monitor
inspection quality with the use of statistical values? And to simply Type BVS-E
adapt your inspection to changes in components? We have a simple PNP Ordering code BAE00EH
solution: the Vision Sensor Monitor. Part number BAE PD-VS-002-E
It visualizes the sensor images and inspection results and displays Supply voltage UB 24 V DC ±10 %
the process statistics in a simple overview graphic. The detection Dimensions 96×96×42.4 mm
of unwanted deviations thus becomes really simple. If an inspection Connection 2× M12 connector,
feature changes, such as a sell-by date, authorized users can then 4-pin
adapt the inspection criteria even without a PC. Lengthy setting Degree of protection per IEC 60529 IP 40
work is therefore no longer necessary. The monitor allows simple Ambient temperature Ta –10...+55 mm
switching between two inspections. The easy-to-use, intuitive user Display 3.5" color LCD
interface of the monitor can be controlled by operating buttons and
is available in multiple languages.

268
BAV Balluff Added-Value Kits for Vision Sensors
Sensors and accessories – neatly packed

Ever experienced this? You orde-


red the Vision Sensor BVS with
connecting cable. During initial
operation, however, you determi-
ne that the parameterization
cables and mounting brackets
are still missing.

This is why we have integrated


the Vision Sensor BVS with ac-
cessories for you in a package. Description Added-Value Kit with Vision Sensor BVS
You only have to order one item Contains Contains
and you have everything you red light sensor infrared light sensor
need to operate the sensor. Standard 6-mm lens Ordering code SET012P SET0121
An Added-Value Kit contains series Part number BAV BP-PH-00022-01 BAV BP-PH-00068-01
a Vision Sensor in a design of 8-mm lens Ordering code SET012M SET0122
your choice, including software Part number BAV BP-PH-00020-01 BAV BP-PH-00069-01
CD and operating instructions, 12-mm lens Ordering code SET012N SET0123
mounting bracket and instal- Part number BAV BP-PH-00021-01 BAV BP-PH-00070-01
lation accessories, supply and Advanced 6-mm lens Ordering code SET012U SET0124
parameterization cables, which series Part number BAV BP-PH-00025-01 BAV BP-PH-00071-01
means you only have to connect 8-mm lens Ordering code SET012R SET0125
a 24-V power supply unit. If you Part number BAV BP-PH-00023-01 BAV BP-PH-00073-01
do not happen to have a power 12-mm lens Ordering code SET012T SET0126
supply unit, needless to say we Part number BAV BP-PH-00024-01 BAV BP-PH-00074-01
can also supply you with one. Identification 6-mm lens Ordering code SET0128
series Part number BAV BP-PH-00076-01
8-mm lens Ordering code SET012J SET0129
Part number BAV BP-PH-00017-01 BAV BP-PH-00077-01
12-mm lens Ordering code SET012K SET012A
Part number BAV BP-PH-00018-01 BAV BP-PH-00078-01
Universal 6-mm lens Ordering code SET014U SET0150 BVS Vision
series Part number BAV BP-PH-00092-03 BAV BP-PH-00092-07 Sensors
Easy to use –
8-mm lens Ordering code SET014R SET014Y as simple as
Part number BAV BP-PH-00092-01 BAV BP-PH-00092-05 a sensor
12-mm lens Ordering code SET014T SET014Z BVS-E
Ident
Part number BAV BP-PH-00092-02 BAV BP-PH-00092-06
BVS-E
Contents Vision sensor, mounting bracket, Standard
installation accessories, connector, BVS-E
Advanced
software CD and operating instructions
BVS-E
Universal
BVS-E
Vision-Sensor
Monitor
BAV Added-
Value-Kits von
Balluff

■ www.balluff.com 269
Industrial
Networking
and
Connectivity
Industrial Networking and Connectivity −
A selection
From our extensive product line we have put together a selection
for you that covers the most important applications in Industrial
Identification.

270
Industrial Networking and Connectivity −
A selection
Contents

Cables for BIS U 273


Connectors for BIS VM/VL 274
USB connection BIS V service interface 279
Connectors for BIS C 282
Interface cables for BIS M/L 288
Bus connectors 289
Profibus 290
Profinet, Ethernet/IP, Ethernet TCP/IP, EtherCAT 291
Devicenet 294
CC-Link 298
Modules for IO-Link connection 300
Connectors for BIS M Subnet16 302
Power cables and plugs 305
Connectors for vision sensors BVS 308
Unmanaged switches – port switches 310

You will find many additional products in our total product


line, "Industrial networking and connectivity – Intelligent and
comprehensive networking for system technology" or online
at: www.balluff.com.

Basic information
and definitions
can be found
on page 352

■ www.balluff.com 271
Industrial Networking and Connectivity
Cables for BIS U

Connector diagram 5 3 2 4 3

and wiring
1 2

2 2
3 4
5 3

Type 7/16" TNC plug Serial interface RS232 to PC


Max. supply voltage AC UB 60 V AC
Max. supply voltage DC UB 60 V DC
Number of conductors × conductor cross-section 0.94 mm 3×0.34 mm2
Degree of protection as per IEC 60529 IP 68 IP 67
Ambient temperature Ta FRPE –40...+85 °C
static/moving PVC –30...+80 °C/–5...+80 °C
Use For connecting to a processor unit and For connecting to a processor unit
antennas BIS U-6020-053-104-00-ST26
BIS U-6027-054-104-06-ST27

Cable material Color Length Ordering code


Part number
FRPE Black 1m BAM01HL
BIS U-500-EF-01
FRPE Black 2m BAM01HM
BIS U-500-EF-02
FRPE Black 5m BAM01HN
BIS U-500-EF-05
FRPE Black 10 m BAM01HP
BIS U-500-EF-10
PVC Gray 2m BCC00PL
BIS-C-522-PVC-02

Other cable materials, colors, and Ø14.6 Ø20

lengths on request. M12x1


15.1
28.1

54
31
18

41

Ø16.2

31

272
Industrial Networking and Connectivity
Cables for BIS U

Industrial
Networking and
Connectivity
BIS U
BIS VM/VL
BIS C
BIS M/L
Bus connectors
Profibus
Profinet,
Ethernet/IP,
Ethernet TCP/IP,
EtherCAT
Devicenet
CC-Link
IO-Link
BIS M Subnet16
Power cable/plug
BVS
Unmanaged
switches –
port switches

■ www.balluff.com 273
Industrial Networking and Connectivity
Connectors for read/write heads BIS VM/VL, unshielded
and IO-Link connection

Connector diagram
and wiring

Type M12 female/M12 male M12 female/M12 male


Max. supply voltage AC UB 250 V AC 250 V AC
Max. supply voltage DC UB 250 V DC 250 V DC
Number of conductors × conductor cross-section 4×0.34 mm² 4×0.34 mm²
Degree of protection as per IEC 60529 IP 68 IP 68
Ambient temperature Ta Static –40...+90 °C –40...+90 °C
Tensioned –25...+90 °C (UL 80 °C) –25...+90 °C (UL 80 °C)
Use Complementary (NO/NC) / Complementary (NO/NC) /

Cable material Color Length Ordering code


Part number
PUR Black 0.3 m BCC039H BCC03A8
BCC M415-M414-3A-304-PX0434-003 BCC M425-M414-3A-304-PX0434-003
PUR Black 0.6 m BCC039J BCC03A9
BCC M415-M414-3A-304-PX0434-006 BCC M425-M414-3A-304-PX0434-006
PUR Black 1m BCC039K BCC03AA
BCC M415-M414-3A-304-PX0434-010 BCC M425-M414-3A-304-PX0434-010
PUR Black 1.5 m BCC039L BCC03AC
BCC M415-M414-3A-304-PX0434-015 BCC M425-M414-3A-304-PX0434-015
PUR Black 2m BCC039M BCC03AE
BCC M415-M414-3A-304-PX0434-020 BCC M425-M414-3A-304-PX0434-020
PUR Black 3m BCC039N BCC03AF
BCC M415-M414-3A-304-PX0434-030 BCC M425-M414-3A-304-PX0434-030

38.2 48.5
Other cable materials, colors, and 44 48.5

lengths on request.
27

M12x1
Ø14.5

Ø14.5

Ø14.5

M12x1
M12x1

Ø14.5
M12x1

274
Industrial Networking and Connectivity
Connectors for read/write heads BIS VM/VL, unshielded
and IO-Link connection

M12 female/M12 male M12 female/M12 male


250 V AC 250 V AC
250 V DC 250 V DC
4×0.34 mm² 4×0.34 mm²
IP 68 IP 68
–25...+80 °C –25...+80 °C
–25...+80 °C –25...+80 °C
Complementary (NO/NC) / Complementary (NO/NC) /

Ordering code
Part number
BCC039R BCC03AJ
BCC M415-M424-3A-304-PX0434-003 BCC M425-M424-3A-304-PX0434-003
BCC039T BCC03AK
BCC M415-M424-3A-304-PX0434-006 BCC M425-M424-3A-304-PX0434-006
BCC039U BCC03AL
BCC M415-M424-3A-304-PX0434-010 BCC M425-M424-3A-304-PX0434-010
BCC039W BCC03AM
BCC M415-M424-3A-304-PX0434-015 BCC M425-M424-3A-304-PX0434-015
BCC039Y BCC03AN Industrial
Networking and
BCC M415-M424-3A-304-PX0434-020 BCC M425-M424-3A-304-PX0434-020 Connectivity
BCC039Z BCC03AP BIS U
BCC M415-M424-3A-304-PX0434-030 BCC M425-M424-3A-304-PX0434-030 BIS VM/VL
BIS C
BIS M/L
44 38.2 38.2 38.2
Bus connectors
Profibus
Profinet,
27

Ethernet/IP,
31.4

Ethernet TCP/IP,
EtherCAT
Devicenet
M12x1
M12x1
Ø14.5

Ø14.5

CC-Link
IO-Link
Ø14.5 Ø14.5 BIS M Subnet16
M12x1 M12x1
Power cable/plug
BVS
Unmanaged
switches –
port switches

■ www.balluff.com 275
Industrial Networking and Connectivity
Connectors for read/write heads BIS VM/VL, shielded
and IO-Link connection

Connector diagram
and wiring

I II I II
1 1 1 1
2 2 2 2
3 3 3 3
4 4 4 4
5 1) 1) 5 1) Shield to knurl 5 1) 1) 5 1) Shield to knurl

Type M12 female/M12 male M12 female/M12 male


Max. supply voltage AC UB 250 V AC 250 V AC
Max. supply voltage DC UB 250 V DC 250 V DC
Number of conductors × conductor cross-section 4×0.34 mm² 4×0.34 mm²
Degree of protection as per IEC 60529 IP 68 IP 68
Ambient temperature Ta Static –25...+80 °C –25...+80 °C
Tensioned –25...+80 °C –25...+80 °C
Use Complementary (NO/NC) / Complementary (NO/NC) /

Cable material Color Length Ordering code


Part number
PUR Black 3m BCC0C8L BCC0E3J
BCC M415-M414-3A-305-PS0434-030 BCC M415-M424-3A-305-PS0434-030
PUR Black 5m BCC0C02 BCC0E3K
BCC M415-M414-3A-305-PS0434-050 BCC M415-M424-3A-305-PS0434-050
PUR Black 10 m BCC0C03 BCC0E3L
BCC M415-M414-3A-305-PS0434-100 BCC M415-M424-3A-305-PS0434-100
PUR Black 20 m BCC0C04 BCC0E3M
BCC M415-M414-3A-305-PS0434-200 BCC M415-M424-3A-305-PS0434-200

Other cable materials, colors, and 44 48.5 44 38.2

lengths on request.
Ø14.5

Ø14.5

M12x1
Ø14.5

Ø14.5

M12x1

M12x1 M12x1

276
Industrial Networking and Connectivity
Connectors for read/write heads BIS VM/VL, shielded
and IO-Link connection

I II I II
1 1 1 1
2 2 2 2
3 3 3 3
4 4 4 4
5 1) 1) 5 1) Shield to knurl 5 1) 1) 5 1) Shield to knurl

M12 female/M12 male M12 female/M12 male


250 V AC 250 V AC
250 V DC 250 V DC
4×0.34 mm² 4×0.34 mm²
IP 68 IP 68
–25...+80 °C –25...+80 °C
–25...+80 °C –25...+80 °C
Complementary (NO/NC) / Complementary (NO/NC) /

Ordering code
Part number
BCC0E3C BCC0E3N
BCC M425-M414-3A-305-PS0434-030 BCC M425-M424-3A-305-PS0434-030
BCC0E3E BCC0E3P
BCC M425-M414-3A-305-PS0434-050 BCC M425-M424-3A-305-PS0434-050
BCC0E3F BCC0E3R
BCC M425-M414-3A-305-PS0434-100 BCC M425-M424-3A-305-PS0434-100
BCC0E3H BCC0E3T
BCC M425-M414-3A-305-PS0434-200 BCC M425-M424-3A-305-PS0434-200
Industrial
Networking and
38.2 48.5 38.2 38.2
Connectivity
BIS U
BIS VM/VL
BIS C
27

27

31.4

BIS M/L
M12x1

Bus connectors
Profibus
Ø14.5

M12x1
M12x1

Profinet,
Ethernet/IP,
Ø14.5 Ethernet TCP/IP,
M12x1 Ø14.5 Ø14.5
EtherCAT
Devicenet
CC-Link
IO-Link
BIS M Subnet16
Power cable/plug
BVS
Unmanaged
switches –
port switches

■ www.balluff.com 277
Industrial Networking and Connectivity
Connectors for read/write heads BIS VM/VL, shielded

Connector diagram PIN 1: brown PIN 1: brown


PIN 2: white PIN 2: white
and wiring PIN 3: blue PIN 3: blue
PIN 4: black PIN 4: black

Shield to knurl Shield to knurl

Type M12 female M12 female


Max. supply voltage AC UB 250 V AC 250 V AC
Max. supply voltage DC UB 250 V DC 250 V DC
Number of conductors × conductor cross-section 4×0.34 mm² 4×0.34 mm²
Degree of protection as per IEC 60529 IP 68 IP 68
Ambient temperature Ta PUR shielded –40...+80 °C/–25...+80 °C –40...+80 °C/–25...+80 °C
static/moving PVC shielded –20...+105 °C (UL 80 °C) –20...+105 °C (UL 80 °C)

Use Complementary (NO/NC) / Complementary (NO/NC) /

Cable material Color Length Ordering code


Part number
PUR shielded Black 2m BCC032K BCC0331
BCC M415-0000-1A-014-PS0434-020 BCC M425-0000-1A-014-PS0434-020
PUR shielded Black 5m BCC032L BCC0332
BCC M415-0000-1A-014-PS0434-050 BCC M425-0000-1A-014-PS0434-050
PUR shielded Black 10 m BCC032M BCC0333
BCC M415-0000-1A-014-PS0434-100 BCC M425-0000-1A-014-PS0434-100
PVC shielded Gray 2m BCC036A BCC036T
BCC M415-0000-1A-014-VS8434-020 BCC M425-0000-1A-014-VS8434-020
PVC shielded Gray 5m BCC036C BCC036U
BCC M415-0000-1A-014-VS8434-050 BCC M425-0000-1A-014-VS8434-050
PVC shielded Gray 10 m BCC036E BCC036W
BCC M415-0000-1A-014-VS8434-100 BCC M425-0000-1A-014-VS8434-100

Other cable materials, colors, and M12x1 44 Ø14.5 27


lengths on request.
Ø14.5

38.2
M12x1

278
Industrial Networking and Connectivity
Connectors for read/write heads BIS VM/VL, shielded
and USB connection BIS V service interface

2 2
12 34
3 5 1 3 1

4 4
I II
1 1
2 2
3 3
4 4
5

M12 male/USB-A M12 connector


250 V AC 250 V AC
250 V AC 250 V AC
4×0.34 mm² 4×0.34 mm²
IP 68/IP 20 IP 67

–5...+105 °C/–40...+105 °C –25...+85 °C


Complementary (NO/NC) /

Ordering code
Part number

Industrial
Networking and
Connectivity
BIS U
BIS VM/VL
BIS C
BIS M/L
BCC0CR2 BCC0869 Bus connectors
BCC M415-U024-8F-696-VX04T8-018 BCC M474-0000-2A-000-01X475-000 Profibus
Profinet,
Ethernet/IP,
48.5 52.4 13 16 18 Ethernet TCP/IP,
EtherCAT
Devicenet
Ø20

A B CC-Link
IO-Link
2x1 73.0 BIS M Subnet16
14
Power cable/plug
A B BVS
Unmanaged
switches –
port switches
M12x1 M12x1

■ www.balluff.com 279
Industrial Networking and Connectivity
Connectors for read/write heads BIS VM/VL, shielded

Connector diagram 2 3 3 2 2 3 3 2
and wiring 1 8 4 4 8 1 1 8 4 4 8 1
7 5 5 7 7 5 5 7
6 6 6 6
I II I II
1 1 1 1
2 2 2 2
3 3 3 3
4 4 4 4
5 5 5 5
6 6 6 6
7 7 7 7
8 8 8 8

Type M12 female/M12 male M12 female/M12 male

Max. supply voltage AC UB 60 V AC 60 V AC


Max. supply voltage DC UB 60 V DC 60 V DC
Number of conductors × conductor cross-section 8×0.25 mm² 8×0.25 mm²
Degree of protection as per IEC 60529 IP 67 IP 67
Ambient temperature Ta Static –40...+85 °C –40...+85 °C
Tensioned –20...+85 °C –20...+85 °C

Cable material Color Length Ordering code


Part number

PUR Black 0.5 m BCC00R6 BCC00RK


BIS Z-501-PU1-00.5/M BIS Z-502-PU1-00.5/M
PUR Black 1m BCC00R7 BCC00RL
BIS Z-501-PU1-01/M BIS Z-502-PU1-01/M
PUR Black 2m BCC00R8 BCC00RM
BIS Z-501-PU1-02/M BIS Z-502-PU1-02/M
PUR Black 5m BCC00RA BCC00RR
BIS Z-501-PU1-05/M BIS Z-502-PU1-05/M
PUR Black 10 m

PUR Black 20 m

PUR Black 25 m

PUR Black 50 m

Other cable materials, colors, and


lengths on request.

280
Industrial Networking and Connectivity
Connectors for read/write heads BIS VM/VL, shielded,
User-fabricated

2 3 3 2 2 3 3 2 3 2
1 8 4 4 8 1 1 8 4 4 8 1 4 8 1
7 5 5 7 7 5 5 7 5 7
6 6 6 6 6

1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8

M12 female, straight, M12 female, right-angle M12 male, user-fabricated


M12 male, user-fabricated M12 male, user-fabricated
60 V AC 60 V AC 60 V AC
60 V DC 60 V DC 60 V DC
8×0.25 mm² 8×0.25 mm² 8×0.25 mm²
IP 67 IP 67 IP 67
–40...+85 °C –40...+85 °C –40...+85 °C
–20...+85 °C –20...+85 °C

Ordering code
Part number
BCC00TL
BKS-S117-00

Industrial
Networking and
Connectivity
BCC00R9 BCC00RP
BIS U
BIS Z-501-PU1-05/E BIS Z-502-PU1-05/E
BIS VM/VL
BCC00RC BCC00RU BIS C
BIS Z-501-PU1-10/E BIS Z-502-PU1-10/E BIS M/L
BCC00RF BCC00RY Bus connectors
BIS Z-501-PU1-20/E BIS Z-502-PU1-20/E Profibus
BCC00RH BCC00RZ Profinet,
Ethernet/IP,
BIS Z-501-PU1-25/E BIS Z-502-PU1-25/E Ethernet TCP/IP,
BCC00RJ BCC00T0 EtherCAT
BIS Z-501-PU1-50/E BIS Z-502-PU1-50/E Devicenet
CC-Link
IO-Link
Ø14.5 26.5 BIS M Subnet16
M12x1 Power cable/plug
Ø14.7
M12×1

BVS
Unmanaged
switches –
port switches
45

61
61

43506_00

M12x1
M12x1 Ø20
Ø20

Connection included Connection included

■ www.balluff.com 281
Industrial Networking and Connectivity
Connectors for read/write heads BIS C, shielded

Connector diagram 2 2 2 2
5 5
and wiring 1 5 3 1 5 3 1 3 1 3

4 4 4 4

Type M12 female/M12 female M12 female/M12 female


Max. supply voltage AC UB 250 V AC 250 V AC
Max. supply voltage DC UB 250 V DC 250 V DC
Number of conductors × conductor cross-section 4×0.34 mm² 4×0.34 mm²
Degree of protection as per IEC 60529 IP 67 IP 67
Ambient temperature Ta PUR
static/moving PVC –25...+105 °C/–5...+105 °C –25...+105 °C/–5...+105 °C

Cable material Color Length Ordering code


Part number
PUR Black 1m

PUR Black 5m

PUR Black 10 m

PUR drag Black 5m


chain-compatible
PUR drag Black 10 m
chain-compatible
PVC Black 1m BCC00P8 BCC00PC
BIS C-517-PVC-01 BIS C-518-PVC-01
PVC Black 5m BCC00P9 BCC00PE
BIS C-517-PVC-05 BIS C-518-PVC-05
PVC Black 10 m BCC00PA BCC00PF
BIS C-517-PVC-10 BIS C-518-PVC-10

Example: BIS C-517-PVC-_ _


BIS C-518-PVC-_ _
BIS C-324 BIS C-505-PU-_ _
BIS C-506-PU-_ _

BIS C-650 BIS C-621-_ _ _-050-_ _

282
Industrial Networking and Connectivity
Connectors for read/write heads BIS C, shielded

2 2 2 2 2 2
5 5 5 5 1 5 3 1 5 3
1 3 1 3 1 3 1 3

4 4 4 4 4 4

I II
1 1
2 2
3 3
4 4
5 5

M12 female/M12 female M12 female/M12 female M12 female/M12 female


250 V AC 250 V AC 250 V AC
250 V DC 250 V DC 250 V DC
4×0.34 mm² 4×0.34 mm² 5×0.34 mm²
IP 67 IP 67 IP 65
–40...+70 °C/ –5...+70 °C –40...+70 °C/ –5...+70 °C –30...+80 °C/ –5...+80 °C

Ordering code
Part number
BCC00N1 BCC00N6
BIS C-505-PU-01 BIS C-506-PU-01
BCC00N2 BCC00N7
BIS C-505-PU-05 BIS C-506-PU-05
BCC00N3 BCC00N8
BIS C-505-PU-10 BIS C-506-PU-10
BCC00N4 BCC00N9
BIS C-505-PU1-05 BIS C-506-PU1-05 Industrial
BCC00N5 BCC00NA Networking and
Connectivity
BIS C-505-PU1-10 BIS C-506-PU1-10
BIS U
BIS VM/VL
BIS C
BCC00PJ BIS M/L
BIS C-520-PVC-05 Bus connectors
Profibus
Profinet,
Ethernet/IP,
Ethernet TCP/IP,
EtherCAT
Devicenet
CC-Link
IO-Link
BIS M Subnet16
Power cable/plug
BVS
Unmanaged
5 m (±1 %)

switches –
port switches

■ www.balluff.com 283
Industrial Networking and Connectivity
Connectors for read/write heads BIS C, shielded
Interface cables for BIS C

Connector diagram 

and wiring  

Type M8 female/M12 female Serial RJ232


Max. supply voltage AC UB 60 V AC 60 V AC
Max. supply voltage DC UB 60 V DC 60 V DC
Number of conductors × conductor cross-section 3×0.34 mm² 3×0.34 mm²
Degree of protection as per IEC 60529 IP 65 IP 40
Ambient temperature Ta PUR –40...+70 °C/ +5...+70 °C
static/moving PVC –30...+80 °C/–5...+80 °C

Cable material Color Length Ordering code


Part number
PUR Gray 5m BCC00PP
BIS C-523-PU1-05
PUR Black 5m BCC00PN
BIS C-523-PU-05
PVC Gray 1.5 m

PVC Gray 2m BCC00PK


BIS C-521-PVC-02

28
Ø12

L
54

41

31

M12x1
Ø20

284
Industrial Networking and Connectivity
Connectors for read/write heads BIS C, shielded
Interface cables for BIS C

5 3 2 4 3

1 2

2 2
3 4
5 3

Serial RS232 Serial RS232


60 V AC 60 V AC
60 V DC 60 V DC
3×0.34 mm² 3×0.34 mm²
IP 40 IP 40

–30...+80 °C/–5...+80 °C –30...+80 °C/–5...+80 °C

Ordering code
Part number

BCC00PR
BIS C-524-PVC-01.5
BCC00PL
BIS C-522-PVC-02 Industrial
Networking and
Connectivity
Ø20 Ø13 Ø19.6 BIS U
M12x1 M12x1 BIS VM/VL
BIS C
BIS M/L
Bus connectors
52.5
54

Profibus
54

Profinet,
Ethernet/IP,
Ethernet TCP/IP,
EtherCAT
Devicenet
CC-Link
IO-Link
BIS M Subnet16
41

Power cable/plug
BVS
45

Unmanaged
switches –
31 port switches

34

■ www.balluff.com 285
Industrial Networking and Connectivity
Special connectors for BIS C

Example: Connector diagram 2 3


BIS C-350
and wiring 1 8 4
7 5
6

Type Female, 8-pin


Max. supply voltage AC UB 60 V AC
Max. supply voltage DC UB 60 V DC
BIS C -355
Recommended cable LiYCY-0
Number of conductors × conductor cross-section
Degree of protection as per IEC 60529 IP 65
Ambient temperature Ta Static –55...+125 ºC
Tensioned –55...+125 ºC
Use For connecting to
read/write head
BIS C-35_

Cable material Color Length Ordering code


Part number
PUR Black 5m

PUR Black 10 m
BIS C-520
PUR Black 20 m

PUR Black 30 m
BIS C-670 BIS C-654
PVC Gray 5m

BCC011M
BKS-S 45-00

Other cable materials, colors, and


lengths on request.

286
Industrial Networking and Connectivity
Special connectors for BIS C

2 2 3 2 2 2
3 3
1 4 8 1 5 5
4 8 1 8 4 1 3 1 3
5 7 7 5 5 7
6 6 6 4 4
I II I II
1 1 1 1
2 2 2 2
3 3 3 3
4 4
4 4
5 5
6 6 5 5
7 7
8 8
Male, 6-pin Female, 8-pin / male, 6-pin Female, 5-pin 25-pin
60 V AC 60 V AC 60 V AC 60 V AC
60 V DC 60 V DC 60 V DC 60 V DC
LiYCY-0 LiYCY-0 LiYCY-0
8×0.34 mm2
IP 65 IP 65 IP 65 IP 40
–30...+80 ºC –30...+80 °C –30...+80 ºC –40...+85 ºC
–30...+80 ºC –5...+80 °C –5...+80 ºC –40...+85 ºC
For expansion with For read/write head Connection cable For processors
BKS-S 45-00 BIS C-350 adapter BIS C-355 and BIS C-654 BIS C-605-...
BIS C-670

Ordering code
Part number
BCC00P4
BIS C-516-PU-05
BCC00P5
BIS C-516-PU-10 Industrial
BCC00P6 Networking and
Connectivity
BIS C-516-PU-20
BIS U
BCC00P7 BIS VM/VL
BIS C-516-PU-30 BIS C
BCC00PJ BIS M/L
BIS C-520-PVC-05 Bus connectors
BCC011N BCC00T6 Profibus
BKS-S 46-00 BKS-S 52-00 Profinet,
Ethernet/IP,
Ethernet TCP/IP,
EtherCAT
Devicenet
CC-Link
IO-Link
BIS M Subnet16
Power cable/plug
Order length _ _ (±1 %)

BVS
Unmanaged
switches –
port switches

■ www.balluff.com 287
Industrial Networking and Connectivity
Interface cables for BIS M/L-4...

Connector diagram 2 3 2 3 1 WH 2 3 1 WH
and wiring 2 GN 2 GN
1 8 4 1 8 4 3 YE 1 8 4 3 YE
7 5 7 5 4 GY 7 5 4 GY
6 6 BN 6 BN
5 5
6 PK 6 PK
7 BU 7 BU
8 RD 8 RD

Type M12 female, straight, 8-pin M12 female, straight, 8-pin M12 female, right-angle, 8-pin,
Max. supply voltage AC UB 60 V AC 30 V 30 V
Max. supply voltage DC UB 60 V DC 36 V 36 V
Number of conductors × 8×0.25 mm2 8×0.25 mm2
conductor cross-section
Degree of protection as per IEC 60529 IP 67 IP 67 (when screwed into place) IP 67 (when screwed into place)
Ambient temperature Ta –40...+85 °C –25...+90 °C –25...+90 °C

Cable Color Length Ordering code


material Part number
PUR Black 2m BCC00YE BCC00YU
BKS-S115-PU-02 BKS-S116-PU-02
PUR Black 5m BCC00YF BCC00YW
BKS-S115-PU-05 BKS-S116-PU-05
PUR Black 10 m BCC00YH BCC00YY
BKS-S115-PU-10 BKS-S116-PU-10
PUR Black 15 m BCC00YJ BCC00YZ
BKS-S115-PU-15 BKS-S116-PU-15
BCC00YA
BKS-S115-00

Other cable materials, colors,


and lengths on request.

BIS M-400-_ _

BIS M-401-_ _ BIS L-4_ _


BCC00YU
BCC00YE

BCC00YA

288
Industrial Networking and Connectivity
Bus connectors

8 1 8 1 9
2 2 12 8 1 10
7 9 7 9 7 2
6 3 6 3
5 4 6 3
5 4
5 11 4

M23 connector, 9-pin M23 socket, 9 pin M23 connector, 12-pin


250 V 250 V 250 V
250 V 250 V 250 V
9×0.34 mm2 9×0.34 mm2 12×0.34 mm2

IP 67 IP 67 IP 67
–40...+125 °C –40...+125 °C –40...+125 °C

Ordering code
Part number

Industrial
BCC00T9 BCC00TA BCC00TC Networking and
Connectivity
BKS-S 83-00 BKS-S 84-00 BKS-S 86-00
BIS U
BIS VM/VL
BIS C
BIS C-6021
BIS L-6021 BIS M/L
BIS M-6021 Bus connectors
BIS S-6022
Profibus
Profinet,
Ethernet/IP,
Ethernet TCP/IP,
EtherCAT
BKS S 7900-
Devicenet
CC-Link
BKS S 8300- IO-Link
BIS M Subnet16
BKS S 8400- Power cable/plug
BVS
Unmanaged
switches –
port switches
BIS C 522-PVC-_ _

BKS S 7900-

■ www.balluff.com 289
Industrial Networking and Connectivity
Profibus

2 2 2 2
Connector diagram
5 5 5 5
and wiring 3 1 3 1 1 3 1 3

4 4 4 4

Type M12 male, straight, M12 male, right-angle, M12 female, straight, M12 female, right-angle,
5-pin, B-coded 5-pin, B-coded 5-pin, B-coded 5-pin, B-coded
Ordering code BCC0714 BCC0716 BCC0715 BCC0717
Part number BCC M475-0000-2B-000-01X575-000 BCC M485-0000-2B-000-01X575-000 BCC M475-0000-1B-000-01X575-000 BCC M485-0000-1B-000-01X575-000
Supply voltage UB 10...30 V DC 10...30 V DC 10...30 V DC 10...30 V DC
Number of conductors × 5× max. 0.75 mm2 5× max. 0.75 mm2 5× max. 0.75 mm2 5× max. 0.75 mm2
conductor cross-section
Min. c able diameter Max. 8 mm Max. 8 mm Max. 8 mm Max. 8 mm
Connection Screw terminal Screw terminal Screw terminal Screw terminal
Degree of protection as per IEC 60529 IP 67 IP 67 IP 67 IP 67
Ambient temperature Ta –25...+85 °C –25...+85 °C –25...+85 °C –25...+85 °C
Housing material Brass, coated Brass, coated Brass, coated Brass, coated
Shielded design Yes Yes Yes Yes

Ø20.2 20.2
Ø20.2 M12×1 41.8 Ø20.2 M12×1 36.7

18
54.9

57.4

56.0
63.7

18
18

BIS L-6002 BIS C -6022


BIS M-6002 BIS L-6022
BIS S-6002 BIS M-6022
BIS S-6022

BCC06Z9

BCC0715

BCC0714
BIS C 522-PVC-_ _
BCC M415-M412

BCC06Z9
BCC06Z9

BCC0715

BCC0714

BCC0718

290
Industrial Networking and Connectivity
Profibus

Connector diagram 2 2
1
and wiring 3 5 1 1 5 3
2
4 4
1 1
1 NC
2 2
2 Line A green R1 R2 R3 R1 R2 R3
3 3
3 NC
4 4
4 Line B red
5 5
5 NC

Type M12 female, straight / Terminating resistor Terminating resistor M12 PUR cable, shielded
M12 male, straight M12 male, straight, 5-pin, female, straight, 5-pin,
B-coded B-coded
Supply voltage US 300 V 10...30 V DC 10...30 V DC
Number of conductors × 2×0.64 mm2 2×0.25 mm2
conductor cross-section
Degree of protection as per IEC 60529 IP 67 IP 67 IP 67 IP 67
Ambient temperature Ta –20...+70 °C –40...+85 °C –40...+85 °C –20...+60 °C

Cable Color Length


material
BCC0718 BCC0C6E
BCC M415-0000-2B-R01 BCC M415-0000-1B-R01
PUR Violet 0.3 m BCC0A11
BCC M415-M412-3B-329-PS72N1-003
PUR Violet 0.6 m BCC0A12
BCC M415-M412-3B-329-PS72N1-006 Industrial
PUR Violet 1 m BCC0A13 Networking and
Connectivity
BCC M415-M412-3B-329-PS72N1-010
BIS U
PUR Violet 2 m BCC0A14
BIS VM/VL
BCC M415-M412-3B-329-PS72N1-020 BIS C
PUR Violet 5 m BCC0A15 BIS M/L
BCC M415-M412-3B-329-PS72N1-050 Bus connectors
PUR 100 m BCC0ACA Profibus
BCC 0000-0000-00-000-PS72N1-10X Profinet,
Ethernet/IP,
Ethernet TCP/IP,
EtherCAT
Other cable lengths
A

Ø14.5 Ø14.5 Devicenet


on request. A CC-Link
IO-Link
Ø14.5

13 13
BIS M Subnet16
Power cable/plug
48.5
44

53.5

M12x1
44

BVS
49

Unmanaged
switches –
port switches
M12x1

M12x1

ØD

B
48.5
Ø14.5

M12x1
B

■ www.balluff.com 291
Industrial Networking and Connectivity
Profinet, Ethernet/IP, Ethernet TCP/IP, EtherCAT

Connector diagram  2

and wiring   1 3

4


Type M12 male, straight, M12 female, straight,


4-pin, D-coded 4-pin, D-coded
Supply voltage UB 60 V AC/DC 60 V AC/DC
Number of conductors × conductor cross-section 4×0.75 mm2 4×0.75 mm2
Degree of protection as per IEC 60529 IP 67 IP 67
Ambient temperature Ta –25...+85 °C –25...+85 °C
Connection Cage clamp Cage clamp

Cable material Color Length Ordering code


Part number
BCC03WZ BCC03Y1
BCC M474-0000-2D-000-51X475-000 BCC M474-0000-1D-000-51X475-000
PUR shielded Green 0.6 m

PUR shielded Green 2m

PUR shielded Green 5m

PUR shielded Green 10 m

PUR shielded Green 15 m

PUR shielded Green 20 m

PUR shielded Green 30 m

BIS M-6026 Ø20.2 Ø20.2

BCC06Z9
18
57.4
63.7

BIS M-407
BCC03Y1

BCC0C5J
BCC M414-E834
BIS C 522-PVC-_ _

M12x1
BCC M414-E834

M12x1
BCC03WZ
BCC0C5J
BCC06Z9

BCC0629

292
Industrial Networking and Connectivity
Profinet, Ethernet/IP, Ethernet TCP/IP, EtherCAT

 2 2 2
  3 1
3 1 3 1
 4

4  4
I II I II
1 1 1 1
2 2 2 2
3 3 3 3
4 4 4 4
5 5
6 6
7 7
8 8

M12 female, right-angle, M12 male, right-angle, M12 male, straight/ M12 male, straight/
4-pin, D-coded 4-pin, D-coded RJ45 male, straight RJ45 female, straight
60 V AC/DC 60 V AC/DC 60 V AC/DC 60 V AC/DC
4×0.75 mm2 4×0.75 mm2 4×22 AWG 4×22 AWG
IP 67 IP 67 IP 68/IP 20 IP 40
–25...+85 °C –25...+85 °C –20...+60 °C –20...+80 °C
Screw plug Screw plug

Ordering code
Part number
BCC03Y2 BCC03Y0
BCC M484-0000-1D-000-51X475-000 BCC M484-0000-2D-000-51X475-000
BCC04K6 BCC0C5J
BCC M414-E834-8G-668-PS54T2-006 BIS C-526-PU-00.6
BCC04K7
BCC M414-E834-8G-668-PS54T2-020
BCC04K8
BCC M414-E834-8G-668-PS54T2-050
Industrial
BCC04K9 Networking and
BCC M414-E834-8G-668-PS54T2-100 Connectivity
BCC04ZJ BIS U
BIS VM/VL
BCC M414-E834-8G-668-PS54T2-150
BIS C
BCC04KA
BIS M/L
BCC M414-E834-8G-668-PS54T2-200
Bus connectors
BCC04KC Profibus
BCC M414-E834-8G-668-PS54T2-300 Profinet,
Ethernet/IP,
$

Ethernet TCP/IP,
EtherCAT
20.2 Ø20.2
Devicenet
$

M12×1 36.7 M12×1 41.8


CC-Link
IO-Link
BIS M Subnet16
M12x1

M12x1
48.5

48.5

Ø14.5 Ø14.5 Power cable/plug


BVS
54.9
56.0

Unmanaged
18 18 switches –
port switches

15.9
57
13.7

■ www.balluff.com 293
Industrial Networking and Connectivity
Devicenet

Connector diagram
and wiring

Type 7/8" female, 5-pin 7/8" plug, 5-pin


Supply voltage UB 300 V 300 V
Number of conductors × conductor cross-section 5× max. 1.5 mm2 5× max. 1.5 mm2
Degree of protection as per IEC 60529 IP 67 IP 67
Ambient temperature Ta –25...+80 °C –25...+80 °C

Cable material Color Ordering code


Cable dia. Part number
PUR Black BCC070F BCC070K
8...10 mm BCC A335-0000-10-000-61X5A5-000 BCC A335-0000-20-000-61X5A5-000

Other cable diameters on request.

BIS C-6023
BIS L-6023
BIS M-6023
BIS S-6023

BCC06Z9

BCC0A0A
BCC070K

BCC070F
BIS C 522-PVC-_ _

BCC06Z9

294
Industrial Networking and Connectivity
Devicenet

3 3 3 3
4 2 2 4 2 4 4 2
5 1 1 5 1 5 5 1

1 1
2 2
3 3
4 4
5 5

1 2 3 4 5
7/8" female, 5-pin 2×7/8" female, 7/8" male, 5-pin 7/8" screw plug
50 V 300 V AC

IP 68 IP 67
–25...+80 °C –40...+90 °C –20...+80 °C

Ordering code
Part number

BCC0A0A BCC0AA7 BAM012T


BCC A315-0000-1A-R04 BCC A315-A315-A315-T0023-000 BKS-7/8-CS-00-A

82.1

Industrial
50

7/8¨-16UN 7/8¨-16UN 7/8¨-16UN Networking and


Connectivity
BIS U
BIS VM/VL
BIS C
67.1

BIS M/L
Bus connectors


Profibus
Ø26

29 28 Profinet,
Ethernet/IP,
Ethernet TCP/IP,
7/8''-16UN EtherCAT
Devicenet
CC-Link
IO-Link
BIS M Subnet16
Power cable/plug
BVS
Unmanaged
switches –
port switches

■ www.balluff.com 295
Industrial Networking and Connectivity
Devicenet

Connector diagram 2 2 2 2
and wiring 1 5 3 1 5 3 5 5
3 1 1 3

4 4 4 4
1 1 1
2 2 2
3
3 3 4
4 4 R1
5
5 5
R1= 121 Ω

1 2 3 4 5

Type 2×M12 female, M12 male, 5-pin M12 socket, 5 pin


Ordering code BCC07WR BCC0A08
Part number BDN T-DTN-DD-01 BCC M415-0000-1A-R04
Supply voltage UB 300 V AC 10...30 V DC
Degree of protection as per IEC 60529 IP 68 IP 68
Ambient temperature Ta –36...+60 °C –40...+85 °C
Housing material Plastic Plastic

Ø14.7 17.0 Ø14.5

M12x1

2.8 13
55.9 Ref.
Ø14.7

44
Ø4.7
10.4

49
Ø8.0
M12x1
M12x1

Ø14.7
45.2 Ref.

BIS C -6003
BIS L-6003
BIS M-6003
M12x1

BIS S-6003
BCC0A08
BCC06YA

BCC0E03
BCC06Z9

BCC06ZF

BCC07WR
BCC07YC

296
Industrial Networking and Connectivity
Devicenet

Connector diagram 2 PIN 1: shield 2 PIN 1: shield 2 2 PIN 1: shield


5 PIN 2: red 5 PIN 2: red 5 PIN 2: red
and wiring 1 3 PIN 3: black 3 1 PIN 3: black 1 3 3 5
1 PIN 3: black
PIN 4: white PIN 4: white PIN 4: white
4 PIN 5: blue 4 PIN 5: blue 4 4 PIN 5: blue
I II
1 1 1 1
2 2 2 2
3 3 3 3
4 4 4 4
5 5 5 5

Type M12 female, straight M12 male, straight M12 female, straight /
M12 male, straight
Supply voltage UB 30 V 30 V 30 V
Number of conductors × 2×24 AWG + 2×22 AWG 2×24 AWG + 2×22 AWG 2×24 AWG + 2×22 AWG
conductor cross-section
Degree of protection as per IEC 60529 IP 68 IP 68 IP 68
Ambient temperature Ta –20...+80 °C –20...+80 °C –20...+80 °C

Standard lengths Ordering code


Part number
0.6 m BCC0E03
BCC A415-A415-3A-330-VS85N6-006
2m BCC0CZW BCC0E00 BCC0E04
BCC A415-0000-1A-030-VS85N6-020 BCC A415-0000-2A-030-VS85N6-020 BCC A415-A415-3A-330-VS85N6-020
5m BCC0CZY BCC0E01 BCC0E05
BCC A415-0000-1A-030-VS85N6-050 BCC A415-0000-2A-030-VS85N6-050 BCC A415-A415-3A-330-VS85N6-050
10 m BCC0CZZ BCC0E02 BCC0E06
BCC A415-0000-1A-030-VS85N6-100 BCC A415-0000-2A-030-VS85N6-100 BCC A415-A415-3A-330-VS85N6-100
15 m BCC0E07 Industrial
BCC A415-A415-3A-330-VS85N6-150 Networking and
Connectivity
BIS U
A

BIS VM/VL
A
BIS C
Ø14.5

BIS M/L
Bus connectors
Profibus
44
44

M12x1
48.5

Profinet,
Ethernet/IP,
Ethernet TCP/IP,
EtherCAT
Devicenet
CC-Link
IO-Link
BIS M Subnet16
Ø14.5

Ø14.5

Power cable/plug
BVS
M12x1 M12x1 Unmanaged
B
switches –
48.5

port switches
Ø14.5

M12x1
B

■ www.balluff.com 297
Industrial Networking and Connectivity
CC-Link

Connector diagram    
PIN 1: shield PIN 1: shield PIN 1: shield
and wiring  PIN 2: white PIN 2: white  PIN 2: white
       
PIN 3: yellow PIN 3: yellow PIN 3: yellow
PIN 4: blue PIN 4: blue PIN 4: blue
   

Type M12 female, straight M12 male, straight M12 female, straight /
M12 male, straight
Supply voltage UB 250 V 250 V 250 V
Number of conductors × 3×1×AWG20 3×1×AWG20 3×1×AWG20
conductor cross-section
Degree of protection as per IEC 60529 IP 67 IP 67 IP 67
Ambient temperature Ta –25...+70 °C –25...+70 °C –25...+70 °C

Cable Color Length Ordering code


material Part number
PVC Red 0.6 m BCC06WU
BCC M415-M414-3A-337-VS24N7-006
PVC Red 2m BCC06Y1 BCC084R BCC06WW
BCC M415-0000-1A-068-VS24N7-020 BCC M414-0000-2A-068-VS24N7-020 BCC M415-M414-3A-337-VS24N7-020
PVC Red 5m BCC06Y2 BCC084T BCC06WY
BCC M415-0000-1A-068-VS24N7-050 BCC M414-0000-2A-068-VS24N7-050 BCC M415-M414-3A-337-VS24N7-050
PVC Red 10 m BCC06Y3 BCC084U BCC06WZ
BCC M415-0000-1A-068-VS24N7-100 BCC M414-0000-2A-068-VS24N7-100 BCC M415-M414-3A-337-VS24N7-100
PVC Red 15 m BCC06Y0
BCC M415-M414-3A-337-VS24N7-150

š
Other cable materials, colors
and lengths on request.
0[






š' š'
š'
/
š
š

0[ 0[

0[

š

298
Industrial Networking and Connectivity
CC-Link

Connector diagram 2 2 2 2

3 1 3 1 1 5 3 1 5 3

4 4 4 4

Version M12 male, straight M12 male, straight M12 female, straight M12 female, straight
Max. supply voltage 250 V AC 250 V AC 250 V AC 250 V AC
AC UB
Max. supply voltage 250 V DC 250 V DC 250 V DC 250 V DC
DC UB
Cable User-fabricated User-fabricated User-fabricated User-fabricated
Number of conductors × 4×0.14...0.75 mm² 4×0.14...0.50 mm² 4×0.14...0.75 mm² 4×0.14...0.50 mm²
conductor cross-section
Connection Screw terminal Spring clamp terminal Screw terminal Spring clamp terminal
Degree of protection as per IEC 60529 IP 67 IP 67 IP 67 IP 67
Ambient temperature Ta –40...+85 °C –25...+85 °C –40...+85 °C –25...+85 °C

Cable dia. Ordering code


Part number
6...8 mm BCC06F7 BCC06Y5 BCC06F6 BCC06Y6
BCC M434-0000-2A-000-51X475-000 BCC M434-0000-2A-000-55X450-000 BCC M435-0000-1A-000-51X475-000 BCC M435-0000-1A-000-55X450-000

20.2 Ø20.2 Ø20.2 Ø20.1


M12x1
18
17
18
18
18
59.2

61.2
17
63
63

14 Industrial
13 Networking and
14
Connectivity
16 BIS U
16
BIS VM/VL
13
BIS C
BIS M/L
Bus connectors
M12x1
M12x1

M12x1

Profibus
Profinet,
Ethernet/IP,
Ethernet TCP/IP,
EtherCAT
Devicenet
CC-Link
IO-Link
BIS M Subnet16
Power cable/plug
BVS
Unmanaged
switches –
port switches

■ www.balluff.com 299
Industrial Networking and Connectivity
Master blocks for slave devices

Think of a remote “slice” I/O solution. In a typical application, the device is connected to an industry standard M12 port utilizing a
communication head and the power supply sit on the left hand side basic 3-wire sensor cable for IO-Link communication. With the ability
and are followed along the backplane by the individual I/O devices, to be installed within a 20 meter radius from the data, collector
such as discrete 24V input cards or 0-10V analog cards. Usually devices can be easily distributed across the machine.
there are a limited number of slots available in the backplane and
individual slices of control components can be inserted.

In a similar fashion, an I/O-Link system has a communications head


that talks over the desired industrial network on one side and the
right hand side acts as a data collector. In lieu of a backplane, each

Discrete
Power I/O

RFID or
Discrete Analog Valve Manifold Specialty
I/O I/O Control Devices

Network Protocol Ethernet/IP Devicenet Profinet Profibus


Addressing Display Display Display Rotary Dials
1× IO-Link /
4× RFID BIS VM or VL
4× IO-Link /
4× Configurable
4× IO-Link / BNI004A BNI005A BNI004U BNI003K
12× Configurable BNI EIP-502-105-Z015 BNI DNT-502-100-Z001 BNI PNT-502-105-Z015 BNI PBS-502-001-Z001
8× IO-Link / BNI006A BNI005H*
8× Configurable BNI EIP-508-105-Z015 BNI PNT-508-105-Z015

Consult factory for availability

300
Industrial Networking and Connectivity
Master blocks for slave devices

BIS L-203-03/L Traceability with RFID


With increasing demand for traceability
0...7 mm and production data in the manufacturing
enviornment the need fro data tracking is
BIS L-201-03/L
growing. Using RFID and IO-Link allows for
simple collection of data on one station from
multiple locations.
0...35 mm

BIS M-112-02/L

0...38 mm

BIS M-151-02/A

Industrial
0...65 mm Networking and
Connectivity
BIS U
BIS VM/VL
BIS C
BIS M/L
Bus connectors
Profibus
Profinet,
Ethernet/IP,
Ethernet TCP/IP,
EtherCAT
Devicenet
CC-Link
IO-Link
BIS M Subnet16
Power cable/plug
BVS
Unmanaged
Profibus Profibus Profibus Profibus CC-Link switches –
port switches
Display Rotary Dials Rotary Dials Display Display
BIS00T3
BIS V-6102-019-C001
BNI003P BNI0030
BNI PBS-507-001-Z011 BNI PBS-504-001-K008
BNI005R BNI0040
BNI PBS-502-101-Z001 BNI CCL-502-100-Z001

■ www.balluff.com 301
Industrial Networking and Connectivity
Connectors for BIS M Subnet16

Connector diagram 3 PIN 1: shield 3 3 2 PIN 1: shield


2 4 PIN 2: red 2 4 4 2 PIN 2: red
and wiring PIN 3: black 1 5 3 PIN 3: black
1 5 PIN 4: white 1 5 5 1 PIN 4: white
PIN 5: blue PIN 5: blue
4
I II
1 1 1 1
2 2 2 2
3 3 3 3
4 4 4 4
5 5 5 5

Type 7/8" female, straight 7/8" female, straight / M12 female, straight
7/8" male, straight
Supply voltage UB 30 V 30 V 30 V
Number of conductors × 2×24 AWG, 2×22 AWG 2×24 AWG, 2×22 AWG 2×24 AWG, 2×22 AWG
conductor cross-section
Degree of protection as per IEC 60529 IP 68 IP 68 IP 68
Ambient temperature Ta –20...+80 °C –20...+80 °C –20...+80 °C

Standard lengths Ordering code


Part number
0.6 m BCC09YA
BCC A315-A315-30-330-VS85N6-006
2m BCC09UY BCC09YE BCC0CZW
BCC A315-0000-10-030-VS85N6-020 BCC A315-A315-30-330-VS85N6-020 BCC A415-0000-1A-030-VS85N6-020
5m BCC09W0 BCC09YJ BCC0CZY
BCC A315-0000-10-030-VS85N6-050 BCC A315-A315-30-330-VS85N6-050 BCC A415-0000-1A-030-VS85N6-050
10 m BCC09W3 BCC09YP BCC0CZZ
BCC A315-0000-10-030-VS85N6-100 BCC A315-A315-30-330-VS85N6-100 BCC A415-0000-1A-030-VS85N6-100
15 m BCC09YT
BCC A315-A315-30-330-VS85N6-150
Cable Ø 4...6 mm, no LED,
NO and NC

7/8''-16UN 7/8''-16UN
50
Ø26

44
50

7/8''-16UN
Ø14.5
53.3
Ø26

Ø26

M12x1

302
Industrial Networking and Connectivity
Connectors for BIS M Subnet16

2 PIN 1: shield 2 2
PIN 2: red
5 5 5
3 1 PIN 3: black 3 1 1 3
PIN 4: white
PIN 5: blue
4 4 4

1
2
3
4
5

M12 male, straight M12 male, straight M12 female, straight

30 V 125 V 125 V
2×24 AWG, 2×22 AWG 5×0.14...0.75 mm² 5×0.14...0.75 mm²

IP 68 IP 67 IP 67
–20...+80 °C –40...+85 °C –40...+85 °C

Ordering code
Part number

BCC0E00
BCC A415-0000-2A-030-VS85N6-020
BCC0E01
BCC A415-0000-2A-030-VS85N6-050
BCC0E02
BCC A415-0000-2A-030-VS85N6-100
Industrial
Networking and
Connectivity
BCC06YA BCC06ZF
BIS U
BCC M435-0000-2A-000-41X575-000 BCC M435-000-1A-000-41X575-000 BIS VM/VL
BIS C
Ø20.2 Ø20.2 BIS M/L
Bus connectors
Profibus
Profinet,
48.5

18 18 Ethernet/IP,
Ethernet TCP/IP,
EtherCAT
59.2
64.1

Devicenet
CC-Link
13 IO-Link
14 14
BIS M Subnet16
Power cable/plug
Ø14.5

13 BVS
Unmanaged
M12x1 switches –
port switches
M12x1
M12x1

■ www.balluff.com 303
Industrial Networking and Connectivity
Connectors for BIS M Subnet16™

Connector diagram 3
2
3 3 
2 4 4 2 4 2
and wiring 1 5 3 



1 5 5 1 5 1

4

1 1 1 1
2 2 2 2
3 3 3 3
4 4 4 4
5 5
R1 R1
5 5

R1= 120 Ω R1= 121 Ω


1 2 3 4 5

Type 7/8" male, 7/8" female, Terminating resistor Terminating resistor


M12 female 7/8" male, straight M12 male, straight
Supply voltage UB 300 V AC 50 V 50 V
Version Standard, 5-pin Male standard 5-pin DN 5-pin A-coded
No. of conductors × conductor
cross-section
Degree of protection as per IEC 60529 IP 67 IP 68 IP 68
Ambient temperature Ta –20...+80 °C –25...+80 °C –40...+85 °C
Use

Cable Color Length Ordering code


material Part number
PUR Black 2m

PUR Black 5m

PUR Black 10 m

BCC07WZ BCC0A09 BCC09MR


BDN T-DTE-AD-01 BCC A315-0000-2A-R04 BCC M415-0000-2A-R04

25.4
Other cable materials, 7/8"-16UN Ø14.5

colors, and lengths on request.


Connectors without LED
M12

13
53.3

are suitable for the switching


48.5
53.5

functions PNP and NPN.


25.4

71.9

NPN versions on request.


Ø14.5

Ø4.50X2

Ø26

M12x1

14.9
47.4 7/8''-16UN
7/8"-16UN
28.6

304
Industrial Networking and Connectivity
Power cable and plug

PIN 1: brown 2 2
PIN 2: white
1 5 3 1 5 3
PIN 3: blue
PIN 4: black
4 4

Shield to
knurl

M12 female, straight M12 female, straight, M12 female, straight


for cable Ø 4...6 mm, no LED
250 V 250 V 150 V
5-pin 5-pin
4×0.34 mm² 4×0.14...0.75 mm²

IP 68 IP 67 IP 67
–40...+90 °C/–25...+90 °C (UL 80° C) –40...+85 °C –25...+85 °C
Complementary (NO/NC) / NO/NC

Ordering code
Part number
BCC032F
BCC M415-0000-1A-003-PX0434-020
BCC032H
BCC M415-0000-1A-003-PX0434-050
BCC032J Industrial
BCC M415-0000-1A-003-PX0434-100 Networking and
Connectivity
BCC06Z9 BCC06ZN
BIS U
BCC M435-0000-1A-000-41X475-000 BCC M475-0000-1A-000-01X575-000 BIS VM/VL
BIS C
Ø20.2 Ø20 BIS M/L
M12×1 Bus connectors
Profibus
18 18 Profinet,
Ethernet/IP,
44

Ethernet TCP/IP,
59.2

67.7

16 EtherCAT
13 Devicenet
14
13 CC-Link
IO-Link
BIS M Subnet16
M12x1

Power cable/
plug
M12x1

Ø14.5 BVS
Unmanaged
switches –
port switches

■ www.balluff.com 305
Industrial Networking and Connectivity
Power cables

3 3
Connector diagram PIN 1: black PIN 1: black
2 4 2 4
and wiring PIN 2: blue PIN 2: blue
PIN 3: green/yellow PIN 3: green/yellow
1 5 1 5
PIN 4: brown PIN 4: brown
PIN 5: white PIN 5: white

1 1
2 2
3 3
4 4
5 5

Type 7/8" female 7/8" female


Max. supply voltage UB 300 V DC 300 V DC
Number of conductors × conductor cross-section 5×1.5 mm2 5×1.5 mm2
Degree of protection as per IEC 60529 IP 68 IP 68
Ambient temperature Ta –25...+80 °C –25...+80 °C

Cable material Color Length Ordering code


Part number
PUR Black 0.6 m

PUR Black 2m BCC06HC BCC06HH


BCC A315-0000-10-063-PX05A5-020 BCC A325-0000-10-063-PX05A5-020
PUR Black 5m BCC06HE BCC06HJ
BCC A315-0000-10-063-PX05A5-050 BCC A325-0000-10-063-PX05A5-050
PUR Black 10 m BCC06HF BCC06HK
BCC A315-0000-10-063-PX05A5-100 BCC A325-0000-10-063-PX05A5-100
PUR Black 15 m

37.5 Ø26

Other cable materials, colors, and


lengths on request.
7/8" - 16 UN
50

52.7
Ø26

7/8" - 16 UN

306
Industrial Networking and Connectivity
Power cables

3 3 3 3 3 3 3 3

2 4 4 2 2 4 4 2 2 4 4 2 2 4 4 2

1 5 5 1 1 5 5 1 1 5 5 1 1 5 5 1

I II I II I II I II
1 1 1 1 1 1 1 1
2 2 2 2 2 2 2 2
3 3 3 3 3 3 3 3
4 4 4 4 4 4 4 4
5 5 5 5 5 5 5 5

7/8" female / 7/8" male 7/8" female / 7/8" male 7/8" female / 7/8" male 7/8" female / 7/8" male
300 V DC 300 V DC 300 V DC 300 V DC
5×1.5 mm2 5×1.5 mm2 5×1.5 mm2 5×1.5 mm2
IP 68 IP 68 IP 68 IP 68
–25...+80 °C –25...+80 °C –25...+80 °C –25...+80 °C

Ordering code
Part number
BCC06FM BCC06FU BCC06H1 BCC06H6
BCC A315-A315-30-335-PX05A5-006 BCC A315-A325-30-335-PX05A5-006 BCC A325-A315-30-335-PX05A5-006 BCC A325-A325-30-335-PX05A5-006
BCC06FN BCC06FW BCC06H2 BCC06H7
BCC A315-A315-30-335-PX05A5-020 BCC A315-A325-30-335-PX05A5-020 BCC A325-A315-30-335-PX05A5-020 BCC A325-A325-30-335-PX05A5-020
BCC06FP BCC06FY BCC06H3 BCC06H8
BCC A315-A315-30-335-PX05A5-050 BCC A315-A325-30-335-PX05A5-050 BCC A325-A315-30-335-PX05A5-050 BCC A325-A325-30-335-PX05A5-050
BCC06FR BCC06FZ BCC06H4 BCC06H9
BCC A315-A315-30-335-PX05A5-100 BCC A315-A325-30-335-PX05A5-100 BCC A325-A315-30-335-PX05A5-100 BCC A325-A325-30-335-PX05A5-100
BCC06FT BCC06H0 BCC06H5 BCC06HA
BCC A315-A315-30-335-PX05A5-150 BCC A315-A325-30-335-PX05A5-150 BCC A325-A315-30-335-PX05A5-150 BCC A325-A325-30-335-PX05A5-150
Industrial
Ø26 Ø26 37.5 Networking and
A

Connectivity
BIS U
7/8" - 16 UN

7/8" - 16 UN

A
A

BIS VM/VL
50

52.7

BIS C
BIS M/L
A

Bus connectors
I

Profibus
Profinet,
Ethernet/IP,
Ethernet TCP/IP,
L

EtherCAT
Devicenet
CC-Link
II

II

IO-Link
B

BIS M Subnet16
Power cable/
53.3

52.7

plug
7/8" - 16 UN

7/8" - 16 UN

B
B

BVS
Unmanaged
B

Ø26 Ø26 41 switches –


port switches

■ www.balluff.com 307
Industrial Networking and Connectivity
Connectors for vision sensors BVS

Connector diagram PIN 1: white PIN 5: gray


2

and wiring PIN 2: brown PIN 6: pink 5


1 3
PIN 3: green PIN 7: blue
PIN 4: yellow PIN 8: red 4

I II
 1 1
 2 2
 3 3
 4 4
 5

Shield 6 Shield
Open Open
 7
Housing
knurl
 8

Shield to knurl

Type M12 female, straight M12 female, straight /RJ45


Power supply max. UB 60 V DC 60 V DC
Number of conductors × conductor cross-section 8×0.25 mm² 4×0.34 mm²
Degree of protection as per IEC 60529 IP 67 IP 67/IP 20
Ambient temperature PUR
Ta PUR shielded –25...+80 °C/–50...+80 °C
static/moving PVC
Use Connection cables for Parameterization cables for
Vision Sensors BVS-E Vision Sensors BVS-E

Cable material Length Ordering code


Part number
PUR 2m BCC0994
BCC M418-0000-1A-046-PS0825-020
PUR 5m BCC0995
BCC M418-0000-1A-046-PS0825-050
PUR 10 m BCC0996
BCC M418-0000-1A-046-PS0825-100
PUR 20 m BCC09HL
BCC M418-0000-1A-046-PS0825-200
PUR 40 m BCC0AT8
BCC M418-0000-1A-046-PS0825-400
PVC 2m

PVC 5m

PVC 10 m

TPE 5m BCC0E7T
BCC M415-E834-AG-672-ES64N8-050
TPE 10 m BCC0E7W
BCC M415-E834-AG-672-ES64N8-150

Other cable materials, colors, and Ø14.5

lengths on request
44
M12x1

308
Industrial Networking and Connectivity
Connectors for vision sensors BVS

2 2
PIN 1: brown  PIN 1: brown
5 5 PIN 2: white PIN 3: blue
1 3 1 3  
PIN 3: blue PIN 4: black
4 4
PIN 4: black
I II
1 1
2 2
3 3
4 4
5 1) 1) 5

1) Shield to knurl

M12 female, straight / M12 female, straight M12 female, straight M8 female, straight
250 V DC 250 V DC 60 V DC
5×0.34 mm² 4×0.34 mm² 3×0.34 mm²
IP 67 IP 68 IP 67
–25...+80 °C –25...+90 °C/–25...+90 °C (UL 80 °C)

–5...+80 °C
Connection cables for vision sensors BVS-E Connection cables for BVS Monitor and Connection cables for coaxial lighting
and BVS Monitor lighting

Ordering code
Part number
BCC0ANA BCC032F BCC02M8
BCC M415-M415-5D-687-ES64N8-020 BCC M415-0000-1A-003-PX0434-020 BCC M313-0000-10-001-PX0334-020
BCC0ANC BCC032H BCC02M9
BCC M415-M415-5D-687-ES64N8-050 BCC M415-0000-1A-003-PX0434-050 BCC M313-0000-10-001-PX0334-050
BCC032J BCC02MA Industrial
BCC M415-0000-1A-003-PX0434-100 BCC M313-0000-10-001-PX0334-100 Networking and
Connectivity
BIS U
BIS VM/VL
BIS C
BIS M/L
BCC0367 BCC02NU Bus connectors
BCC M415-0000-1A-003-VX8434-020 BCC M313-0000-10-001-VX8334-020 Profibus
BCC0368 BCC02NW Profinet,
Ethernet/IP,
BCC M415-0000-1A-003-VX8434-050 BCC M313-0000-10-001-VX8334-050 Ethernet TCP/IP,
BCC0369 BCC02NY EtherCAT
BCC M415-0000-1A-003-VX8434-100 BCC M313-0000-10-001-VX8334-100 Devicenet
CC-Link
IO-Link
BIS M Subnet16
Power cable/plug
BVS
Unmanaged
switches –
 š M8x1 32.2 port switches
š'

0[

Ø9.7

■ www.balluff.com 309
Industrial Networking and Connectivity
Unmanaged switches – port switches

Ethernet 5-port switch IP 20


Ethernet 8-port switch IP 20
Ethernet 9-port switch IP 67
Ethernet-based network systems are gaining more and more
importance in industrial automation. Balluff provides a wide variety
of Ethernet-based systems and network components such as
Profinet or Ethernet/IP for machine and plant equipment.

With Balluff, you receive a complete system so that you can use
Ethernet to link Ethernet system components easily. The Ethernet
product line was expanded with the addition of 5-port and 8-port
Ethernet switches for this reason.

The switch makes it possible to connect 5-port and 8-port Ether- Communication Unmanaged switch
net devices to a component radially. The RJ45 ports and the 10 Version No display
and 100 Mbps transmission rates support this. The transfer speed Ordering code BNI000F
is automatically set via the auto-negotiation function. Wiring errors Part number BNI EIP-950-000-Z009
are reliably ruled out by the autocrossing function. This is because Supply voltage UB 24 V DC
the module does not identify on its own what type of cable is be- Module current consumption 80...100 mA
ing used. Module status indicator: Mod LED Yes
Network status indicator: Yes
Net LED
Network data transfer rate: Yes
Link LED
Port status indicator Black, red, yellow, green
Connection: Fieldbus M12 female, D-coded
Connection: AUX power 7/8" male, 4-pin
Number of Ethernet ports 9
Degree of protection as per IEC 60529 IP 67
Operating temperature 0...+55 °C
Storage temperature –25...+70 °C
Housing material Cast zinc, coated
Transfer rates 10/100 Mbps, automatic
detection, full-duplex
Degree of protection IP 67
Max. switching frequency 32 gigabyte
Overload protection IEEE 802.3
IP address space IPv4
Approvals ODVA, UL-CUL, CSA, CE

68
64.4 31.4
7.5 19.8
1.8
209.4
224

25
25
25
30.5
6.5

Ø7.5 0.3
20.2

310
Industrial Networking and Connectivity
Unmanaged switches – port switches

Communication Ethernet Ethernet


Version Ethernet switch Ethernet switch
Ordering code BNI005E BNI0067
Part number BNI TCP-951-000-E028 BNI TCP-952-000-E029
Ports 5×RJ45 8×RJ45
Spring force clamp Spring force clamp
System power supply 0.2...2.5 mm² 0.2...2.5 mm²
Supply voltage UB 12...48 V DC 2×12...30 V DC, redundant
Transfer rate 10/100 Mbps full duplex 10/100 Mbps full duplex
Auto crossing Auto crossing
Operating modes Auto negotiation Auto negotiation
Communication status Link/run LED, (yellow/green) Link/run LED, (yellow/green)
Supply voltage LED (green), power LED (green), power
Degree of protection IP 20 IP 20
Housing Black plastic Black plastic
Temperature range –10...+60 °C –10...+60 °C
(storage temperature –25...+70 °C) (storage temperature –25...+70 °C)
Fastener Snaps onto support rail TH35 Snaps onto support rail TH35
(EN60715) (EN60715)
Weight 152 g 363 g

Industrial
GND

PWR

30 60
GND

PWR

Networking and
Connectivity
PWR

1
LINK/
ACT BIS U
100

2
LINK/
ACT BIS VM/VL
BIS C
100
This device complies with
Part 15 of the FCC Rules
LINK/ Operation is subject to
110

ACT www.balluff.com the following two condition:


(1) This device may not cause
harmfol interference, and
3 R
I.T.E.
24LJ
(2) This device must accept
any interference reseived.
LISTED E193187 including interference
Input: 10-48 Vdc, 500 mA that may cause undesired

BIS M/L
100 operations. This device complies with
Part 15 of the FCC Rules
Operation is subject to
LINK/
ACT BNI005E www.balluff.com the following two condition:
(1) This device may not cause
harmfol interference, and
4 BNI TCP-951-000-E028 (2) This device must accept
145

I.T.E.
R
24LJ any interference reseived.
LISTED including interference

Bus connectors
E193187
100 Input: 10-48 Vdc, 500 mA that may cause undesired
operations.

5
LINK/
ACT
Profibus
100

BNI TCP-951-000-E028
Profinet,
Ethernet/IP,
76.5 Ethernet TCP/IP,
83.6 EtherCAT
Devicenet
125
CC-Link
132
IO-Link
BIS M Subnet16
Power cable/plug
BVS
Unmanaged
switches –
port switches

■ www.balluff.com 311
Accessories
Accessories − A Selection
Fitting accessories are the optimal peripheral for sensors:
We provide reliable products for time and cost-saving integration
into your automation system and for reliable operation. We have put
together a selection for you from our comprehensive product line.

312
Accessories − A Selection
Contents

BIS Industrial RFID accessories 314


BVS Vision Sensors accessories 325
BAE Lights for Vision Sensors 332
Power supplies 348

Many additional products can be found in our


overall "Accessories Line – The optimum peripherals
for the sensors" or online at: www.balluff.com

Basic information
and definitions
can be found on
page 352

■ www.balluff.com 313
Accessories − A Selection
BIS Industrial RFID accessories

Description Fastening plate


Use For BIS U processor
Ordering code BAM01KN
Part number BIS Z-HW-004





For mounting on profile rail,


steel screw connection.

Included for mounting are:


2 BIS Z-HW-004 retaining plates
4 socket cap screws with
hexagon socket M5×10 DIN 912, A2, 8.8
2 socket cap screws with
hexagon socket M6×12 DIN 912, A2, 8.8
4 washers 5 DIN 125, A2
2 washers 6 DIN 125, A2

314
Accessories − A Selection
BIS Industrial RFID accessories

Fastener set Mounting set RJ45 coupling


For BIS U-100 tag For BIS U-102 tag For Ethernet TCP/IP
BAM01LW BAM01YK BCC09N2
BIS Z-SP-003 BIS Z-HW-005 BCC E878-0000-Z1-41X8T4

27
10

Ø 5.2
27

Ø 10



’æ
Fastener set consisting of: 13
2 plastic distance rollers
2 socket cap screws with hexagon socket,




ISO4762-M 5X22-8,8-A2B
25

22

2 washers D 125-A 5,3-ST-A2P



Included for mounting are:
2 mounting brackets
4 panhead cap screws
4 nuts

Accessories −
A Selection
BIS
Industrial RFID
accessories
BVS
Vision Sensors
accessories
BAE
Lights for
Vision Sensors
Power supplies

Description Crimping tool for RJ45


Ordering code FHW0003
Part number 11023834

■ www.balluff.com 315
Accessories − A Selection
BIS Industrial RFID accessories

Description Antenna holder Clamping cylinder


Use For BIS U-301... and BIS For 1 mounting rod Ø 12 mm
U-302...

Ordering code BAM01JK BAM0031


Part number BIS Z-HW-003 BMS CS-M-D12-IZ
Material Stainless steel Cast zinc

115
28.5 57

5.7
1.8 5
Ø3 121
115
100

75

75 M5 nut
Ø5.5

100 3

28
43

Ø20

Antenna

Mounting bracket

Clamping cylinder

Mounting rod

Base holder

316
Accessories − A Selection
BIS Industrial RFID accessories

Clamping cylinder Base holder Mounting rod clamp Mounting rod Ø 12 mm


For 1 mounting rod Ø 14 mm For 1 mounting rod Ø 12 mm For connecting 2 mounting rods Knurled, length 150 mm
(vertical or horizontal mounting Ø 12 mm
on base plates or profiles)
BAM01Z7 BAM002W BAM002Z BAM002R
BMS CS-M-D14-IZ BMS CU-M-D12-A040-00 BMS CC-M-D12-B-00 BMS RS-M-D12-0150-00
Cast zinc Aluminum Aluminum, anodized Aluminum, anodized

55
Ø 5.5 (2×)

Ø11.95
M5 (2×)

47
M6

1×45°
12.5

20
8.1

10
20

20
.1
M5 nut 12.1 35 6
2
Ø1
M6

Ø11
20

30
PX2345

8 Ø6.5
5.6

15

L
30

10
18

.1
12
Ø 40
45
60

1×45°

Accessories −
A Selection
BIS
The mounting rods are knurled Industrial RFID
full-length. This prevents any accessories
position change. BVS
Vision Sensors
accessories
BAE
Lights for
Vision Sensors
Power supplies

■ www.balluff.com 317
Accessories − A Selection
BIS Industrial RFID accessories

Description Mounting plate Mounting plate


Use For BIS C-324 For BIS C-324
Ordering code BAM00JW BAM01TM
Part number BES Q40-HW-1 BAM MC-XA-016-Q40-1
Material Aluminum, anodized Aluminum, anodized

3 different mounting options

Wired BIS C-324 attached to this mounting plate can be displaced


up to 30 mm. The BIS C-324 can be moved and secured at
the required point by loosening the sensor fastening screws
(M5×25, included in the delivery). Tighten screws! The mounting
plate consists of corrosion-resistant aluminum.

318
Accessories − A Selection
BIS Industrial RFID accessories

Description Retaining system Retaining system


Use For BIS C-324 For BIS C-324
Ordering code BAM00JU BAM00JT
Part number BES HS-01-P1-C8/Q40 BES HS-01-P1-C16/Q40
Material Aluminum, anodized and brass Aluminum, anodized and brass

This retainer system was


designed for securing
BIS C-324 read/write head
to profile sections.

The mounting set consists of:


■ 1 mounting plate
■ 2 slot nuts
■ 2 socket cap screws M5×10
DIN 912 galvanized
■ 2 washers Ø 5,3 DIN 533
■ 2 socket cap screws
■ M5×40 ISO 4762M5×40,
ISO 4762

Accessories −
A Selection
BIS
Industrial RFID
accessories
Description Mounting rail holder set BVS
Use For processor units BIS C/L/M/S-600_ Vision Sensors
accessories
Ordering code BAM012L BAE
Part number BIS Z-HW-001 Lights for
Vision Sensors
Material Aluminum, anodized and PA 6
Power supplies

For easy adjustment


and attachment to profile
sections.

Mounting set BIS Z-HW-001


includes:
■ 1 retaining bracket
■ 1 mounting rail holder
■ 4 socket cap screws with
hexagon socket, according
to DIN 912 (M4×16)
■ 2 socket cap screws with slot,
according to DIN 84 (M3×8)

■ www.balluff.com 319
Accessories − A Selection
BIS Industrial RFID accessories

Description Mounting bracket Mounting clamp holder


Use For mounting on BOSCH pallet For BIS VM read/write head
conveyor system TS1 and TS2) (included in the BIS VM-3_ _ head package)
Ordering code BAM01MY BAM01Y3
Part number BAM MB-XA-010-B07-4 BAM MC-XA-018-B04-4
Material Stainless steel Stainless steel

105.0
6 26.7
0.
3.0

45.0

14.0

11.8
53.5

13.4
6.5
78.2 18.0
M4(4x) 45.0
34.8
47.3
32.0

19.5

Ø5.2
43.0
49.5 Ø5.3 (4x)

Description Mounting bracket Shield


Use For mounting on FlexLink For mounting on FlexLink
puck conveyor system puck conveyor system
Ordering code BAM01UH BAM01Y8
Part number BAM MB-XA-012-B09-4 BAM PC-AM-010-4
Material Stainless steel Stainless steel

54.00
54.7 2.0
40.0
7.0

15.0
30.0

2x Ø6.0
34.7

55.0

Ø5.0
2x M4
30.0 2.5

15.0 1.0
10.0

30.0

320
Accessories − A Selection
BIS Industrial RFID accessories

Description Mounting clamp Mounting clamp Mounting clamp


without positive stop with positive stop with positive stop
Use For Ø 18 mm and For Ø 18 mm and M18 For Ø 30 mm and
M18 housings housings with mounting plate M30 housings
for vertical seating
Ordering code BAM00F7 BAM00F9 BAM00HU
Part number BES 18,0-KB-3 BES 18,0-KB-3-F-SA1 BES 30,0-KB-3-F
Material PA 6 PA 6 PA 6

Ø9 40 Ø9
Ø5.5 24 Ø5.5
Ø6.6
13.5

12

19.5

18
24

Ø11

36
54
39
6

Ø28.75

0.7
12.5
30

30
24.5

6
6

36.5

Ø18 Ø30

6.5
6.5

28 42
40 Ø 18 54

Accessories −
A Selection
Description Mounting bracket Mounting bracket BIS
Industrial RFID
Use For M18 sensors For M30 sensors accessories
Ordering code BAM00EY BAM00HH BVS
Part number BES 18,0-HW-1 BES 30,0-HW-1 Vision Sensors
accessories
Material Aluminum, anodized Aluminum, anodized BAE
Lights for
30.1 Vision Sensors
18.1
Power supplies
11
40

19
60

5
40
14
5.2

40
14
5.2

18
30
30
40

■ www.balluff.com 321
Accessories − A Selection
BIS Industrial RFID accessories

Description Mounting cuff Mounting cuff Mounting cuff Mounting cuff


Hole diameter Ø 14.5 mm Ø 16 mm Ø 18 mm Ø 30 mm
Ordering code BAM00EM BAM00ET BAM00F2 BAM00HN
Part number BES 14,5-BS-1 BES 16,0-BS-1 BES 18,0-BS-1 BES 30,0-BS-1
Material PA 6 PA 6 PA 6 PA 6

12

12
12

18
22 26 26
42
32 36 36
55

Ø8 Ø8 Ø8
Ø 10
Ø 4.5
.5

Ø 4.5 Ø 4.5

4.5
4.5

4.5
14

16

Ø 5.5

5.5
Ø

Ø
20

18
26
26
10

Ø
13
1

13

30
1

38

Ø
19
1.5

Description Clamp with positive stop Clamp with positive stop Clamp with positive stop
Use For sensors Ø 18 mm and M18 For sensors Ø 30 mm and M30 For sensors Ø 30 mm and M30
with thread length ≥ 30 mm with thread length ≥ 30 mm with thread length ≥ 50 mm
Ordering code BAM00FT BAM00J6 BAM00J4
Part number BES 18.0-KH-2S BES 30,0-KH-2S BES 30,0-KH-2L
Material Brass, coated Brass, coated Brass, coated

41
15.5
15.5

3.2
3.2

18
3.2
20.5
20.5

30 41
40

M24×1.5 M36×1.5

M36×1.5

322
Accessories − A Selection
BIS Industrial RFID accessories

Description Nut M18×1 Nut M30×1.5 Nut M18×1 Nut M30×1.5 Nut M18×1 Nut M30×1.5
Ordering code BAM01WJ BAM01WK BAM01W4 BAM01W5 BAM01WL BAM01WM
Part number BAM MC-XA-021-M18-4 BAM MC-XA-021-M30-4 BAM MC-XA-021-M18-2 BAM MC-XA-021-M30-2 BAM MC-XA-021-M18-A BAM MC-XA-021-M30-A
Material Stainless steel Stainless steel Brass, coated Brass, coated Plastic Plastic

40
42 42
28
28 28

36

36
36

24
24
24

4
4

8
4
4

Accessories −
A Selection
Description Spacer BIS
Industrial RFID
For data carriers when mounting on metal accessories
Ordering code BAM018M BVS
Part number BIS Z-SP-001 Vision Sensors
accessories
Material POM BAE
Lights for
Vision Sensors
Power supplies

■ www.balluff.com 323
Accessories − A Selection
BIS Industrial RFID accessories

Description Connection cable Handle


Use Connecting cable for BIS M-4_ _ For read/write head BIS C-300-_ _
systems with coupling for BIS C-703-A
power supply and RS232 interface
Ordering code BCC00T2 BAM012A
Part number BIS Z-AK-001-PU1-03 BIS C-300-HG1
Degree of protection per IEC 60529 IP 40 (only when connected)
Ambient temperature range Ta 0...+70 °C 0...+70 °C
Storage temperature –20...+85 °C
Material POM

Power supply y
Ordering code BAE0049
Part number BIS C-703-A

M18 type
Description Hand grip for ergonomic use
Use For read/write heads or read/write
heads with integrated processors
Ordering code BAM012J
Part number BIS Z-HG-002

M30 type
Description Hand grip for ergonomic use
Use For read/write heads or read/write
heads with integrated processors
Ordering code BAM012K
Part number BIS Z-HG-003

324
Accessories − A Selection
BIS Industrial RFID accessories

Software coupling BIS processor unit for Siemens Simatic S7


For fast integration into the controller. Save time and money with
preconfigured functions. Function modules for linking a Processor
with a Profibus option to a Simatic S7 controller.
The function modules offer the full functionality of the Balluff Proces-
sors. Data are exchanged through the I/O section of the controller.

Advantages:
■ Fast startup
■ Easy to use
■ Full command set

Parameters are configured using the "BIS UHF Manager" software.


One requirement is that the processor is connected to the controlling
system. The parameter settings can be overwritten at any time. The
parameters can be saved in an XML file so that they can be retrieved
whenever needed.

PC
Service tools – for easy startup
Save time and money and use the CD-ROM for simple startup of
your BIS system. Every processor comes with this CD-ROM inclu-
ding service tools to assist you. Accessories −
A Selection
BIS
BISCOMRW Industrial RFID
Processor
This free software allows you to read or program a data carrier using accessories
any common PC. BVS
Vision Sensors
accessories
Requirements: BAE
Lights for
Serial port or USB using a USB to RS232 converter. Vision Sensors
Windows XP or Windows 2000. CD-ROM drive. Power supplies
Read/write head
Processor:
Any processor using Balluff Protocol (-007) and built-in serial port.

Functions:
■ Read data carrier and display the data in ASCII and hex format.
Read/write
■ Edit data and write data to the data carrier.
■ Initialize data carrier for the CRC function.

Data carrier

■ www.balluff.com 325
Accessories − A Selection
BVS Vision Sensors accessories

Mounting is part of optimal


integration of the BVS Vision
Sensor. The variety of different
mounting options allows you to
integrate your BVS ideally into
your machine. Balluff accesso-
ries are perfectly matched to our
sensors.

With flexible Balluff accessories,


you can position the BVS quickly Description Mounting bracket for
without elaborate preparatory Vision Sensor BVS
work or time-consuming plan- Use For mounting on base plates or use of
ning, even if space is limited. You clamping cylinders and mounting system
save material and time by using Ordering code BAM00WN
the right mounting element. Part number BVS Z-MB-01
Material Stainless steel

Appropriate installation accessories


can be found on page 316/317 or in
our accessories product line catalog.

326
Accessories − A Selection
BVS Vision Sensors accessories

Mounting bracket for Mounting bracket for


Vision Sensor BVS and ring light BAE line and background lights BAE
For mounting on base plates or use of For mounting on base plates or use of
clamping cylinders and mounting system clamping cylinders and mounting system
BAM01AC BAM01AE
BAM MB-XA-003-B03-1 BAM MB-XA-002-B02-1
Aluminum, anodized Aluminum, anodized

21.2 102 60
8.7 Ø 25

8.6
4.2

40°

M4
(6×
)

43
Ø 20

30
35
Ø4
75

61.8

.2
61.8

52
30

21.2
30
55
80 50 30
25 M4 (3×)
14
Ø 4.5
(4×)
Ø4
.6

0.6

17.2
Ø6

50°
30

18.5
10

6.6 Ø40
11 Ø 33.1
40
50°

Accessories −
A Selection
BIS
Industrial RFID
3 accessories
BVS
Vision Sensors
accessories
BAE
Lights for
Vision Sensors
Power supplies

■ www.balluff.com 327
Accessories − A Selection
BVS Vision Sensors accessories

3D sensor holder with quick-change plate


The Balluff 3D sensor holder with quick-change plate for industrial
image processing is a novelty on the market. Originally conceived for
vision sensors, this multitalented solution can also hold other sen-
sors of similar size. This only requires replacing the sensor-specific
change plate. The first holders are already being used successfully in
the automotive industry.

Every desired solid angle can be configured, allowing the sensor to


be aligned precisely. Its position even remains intact if the sensor has
to be replaced. That helps minimize downtimes. Simply removing the
sensor with the quick-change plate from the holder is enough. An
optionally used safety screw provides protection from tampering as
needed. Without the correct tool, the sensor cannot be removed.

The industry-ready holder made of anodized aluminum makes its


case by being particularly easy and practical to operate. It fits on
almost all common installation profiles and can be fastened directly
to a machine frame, a worktop or a pallet with 3 holes. In addition,
it offers you substantial design freedom since the base, plate and
holder are installed separately. The holder and change plate can be
ordered separately.

Special properties:
■ Quick selection
■ Exact alignment
■ Stable, robust holder systems
■ Ease of handling

328
Accessories − A Selection
BVS Vision Sensors accessories

Description 3D holder system 3D holder system


Version Holder for quick-change plate Quick-change plate
Ordering code BAM01YT BAM01YP
Part number BMS CUJ-M-S25-D045-00 BMS CS-M-S25-DX15-00
Material Aluminum, anodized Aluminum, anodized

51 55
15.1

4
Ø4.5(x8)

60

24
33
41
M5x18
84

M5x1(x4)
10

24
33
60 Ø4.5(3x)
41

5
M5

3.5
50
Ø45.5
120˚

Ø56
60

M4(x4)

53

Accessories −
A Selection
BIS
Industrial RFID
accessories
BVS
Vision Sensors
accessories
BAE
Lights for
Vision Sensors
Power supplies

■ www.balluff.com 329
Accessories − A Selection
BVS Vision Sensors accessories

Description Lock for Vision Sensor BVS focus ring Display housing for BVS monitor
Use For locking the preset focus For mounting of clamping cylinders
and mounting system BMS
Ordering code BAM0206 BAM01A8
Part number BAM FK-VS-002-03-1 BAM PC-AE-002-1
Material Aluminum, anodized Aluminum, anodized

7.5
45

2
4× Ø 4.2

35

45
7.5

17 3
For clamping cylinder
25 BMS CS-M-D12-IZ

TS 35/7.5
EN 50022

41

106 106

Focus ring lock


BAM FK-VS-002-03-1
The preset focus is locked and
cannot be readjusted. Errors
caused by inadvertently adjust-
ment of the focus are therefore
prevented. If the focus needs to
be readjusted, the focus lock
can be removed in seconds.

330
IP 67+ Accessories − A Selection
BVS Vision Sensors accessories

Optional IP 67+ housing


for BVS Vision Sensors
Balluff now provides an optional
housing for splash water areas
and other problematic envi-
ronments for all sensors in the
Vision Sensor family. With its
IP 67+ protection, it also
provides safe protection during
long-term use in harsh environ-
ments. With a few simple hand Description Protective housing for BVS Vision Sensors
movements, the sensor is easily Use For long-term use in harsh environments
integrated in the robust housing Ordering code BAM01RR
and then mounted on a machine Part number BAM PC-VS-008-1
or system. All functions are then Dimensions 175×80×62 mm
available as usual without any Mounting M4 screws (163×52 mm)
loss. Connection Screwed cable gland M25×1.5
(1× Ø 5 mm, 1× Ø 6 mm)
■ Rugged housing Degree of protection per IEC 60529 IP 67
■ Degree of protection IP 67+ Housing material Cast aluminum, lacquered
■ Flexible handling Optical surface Anti-reflective glass
■ Simply assembly and
80 57 5
mounting
■ Full range of sensor functions 52

■ Inexpensive acquisition

Ø 42
175

163

117.5

Accessories −
A Selection
BIS
Industrial RFID
2× M4 accessories
BVS
Vision Sensors
accessories
BAE
Lights for
Vision Sensors
Power supplies

+ =
■ www.balluff.com
Accessories − A Selection
BAE Lights for Vision Sensors

Lights used in an industrial en-


vironment depend on maximum
reliability, outstanding quality and
a good price/performance ratio.
Balluff offers different versions of
light to suit your needs. Select the
best solution for your task and
profit from our mature technology.

We offer different versions:


■ Background lights
■ Ring lights
■ Line lights
■ Spotlights
■ Coaxial lights
■ Dark field illumination
■ Line Laser

Product overview Background lights Ring lights Line lights


Balluff offers a wide range of ■ Simple monitoring of ■ Compatible mounting ■ Homogeneous, directed light
additional lights because each dimensions and shapes bracket for sensor and light ■ Generate shadows to
image processing task depends ■ Independent of material ■ Shadow free illumination with check features
entirely on the illumination. Only and surface type a high degree of brightness ■ Available with red,
perfect light can provide ideal ■ Various light field sizes ■ For inspections with a infrared and white light
conditions for your inspection. available large working distance

Page 334 Page 338 Page 340


332
Accessories − A Selection
BAE Lights for Vision Sensors

The benefits to you


Highest quality Long service life
Our wide range of lights is subject to strict quality standards. We use only extremely luminous LEDs of the highest quality to
Our lights are protected against damages from burst pulses on manufacture our lights. Our extremely luminous ring and line lights
the connection cable or electrostatic discharge (ESD). EMC tests are equipped with an excess temperature deactivation mechanism
performed by an accredited test laboratory have proven this. to extend the useful life of an LED, which depends primarily on
the temperature load.
Eye safety per IEC 62471
Strong artificial radiation as from LEDs, for example, can affect Simple startup
your vision. Our lights are therefore tested by an independent, You only need a conventional 24 V power supply to connect our
certified test laboratory according to the latest applicable standard lights. Expensive control units are not required. Our background
(IEC 62471). All of our lights are categorized into the "Extempt and dark field lights are connected to a 24 V DC power supply.
group" or "Risk group 1" and are therefore considered extremely That‘s it. Ring and line lights are triggered directly by the Vision
safe. By comparison: the sun falls into risk group 3. Sensor or a PLC.

Fast, simple mounting Boost function


All lights are quick, easy and economical to mount and align with Ring and line lights have a boost function that increases light
the Balluff Mounting System BMS. intensity by 30 % and reduces the influence of ambient light.
Overall process reliability is increased as a result.

Frequently asked questions


What should the distance between the light and the component be? Keep the lighting of the part to be inspected constant.
The light intensity on an object decreases with the working distance. Avoid brightness fluctuations caused by ambient light, sunlight or
Objects positioned further away appear darker than closer objects other external light sources. These fluctuations are the most frequent
as a result, e. g. if a bright object is inspected once at a distance cause of errors in image processing and are often difficult to identify.
of 10 cm and once at 100 cm. The brightness of the object 10 cm Errors can be limited by decreasing the exposure time of the sensor.
is 100 times greater than at a distance of 100 cm. Select the best External lighting may be required in addition to the light inside the
distances between the light source, sensor and target object. sensor. Alternative solutions include covers or any kind of physical
In order to prevent saturation, make sure that the brightness of screen that specifically controls the light within the inspection area.
the light source is correct.
How should the field of view be illuminated?
How should reflective components be illuminated? The entire image area should be illuminated as evenly as possible. Accessories −
A Selection
When inspecting highly reflective surfaces, the sensor must be Avoid extremely bright points or dark areas. The component features
BIS
mounted with extreme care and if necessary an external light you wish to inspect should, however, contrast as much as possible Industrial RFID
should be attached to a suitable bracket in order to maximum and show up clearly on the background. If you wish to check whet- accessories
the contrast between the detected object and the background. her a specific feature is present, you can illuminate the component BVS
Vision Sensors
so that a clear shadow is cast upon the feature you wish to detect. accessories
The Vision Sensor can then detect the feature. BAE
Lights for
Vision Sensors
Power supplies

Spotlights Coaxial lights Dark field illumination Line lasers


■ Accurate illumination ■ Highly uniform lighting ■ Monitors scratches and ■ Bright, zoomable line laser
■ Implement larger inspection ■ For highly reflective surfaces dents in surfaces up to 2000 mm
distances ■ For inspections for prints ■ Independent of material ■ For height detection of parts
■ Available with red and or for Dot-Peen Codes and surface type with triangulation
infrared light ■ Various light field sizes ■ For completeness detection
available of parts

Page 342 Page 344 Page 346 Page 347


■ www.balluff.com 333
Accessories − A Selection
Background lights

Series BAE LX-VS BAE LX-VS


Style Background light Background light
Light type Red light Red light
Ordering code BAE000E BAE000F
Part number BAE LX-VS-HR025 BAE LX-VS-HR050
Supply voltage UB 24 V DC 24 V DC
Operating current 150 mA 250 mA
Trigger Yes
Light field size 25×25 mm 50×50 mm
Emitter, light type LED, red light LED, red light
Wavelength 617 nm 617 nm
Dimension 64.5×43×9.5 mm 105×80×9.5 mm
Attachment M4 screws M4 screws
Connection M12 connector, 4-pin M12 connector, 4-pin
Housing material Aluminum, anodized Aluminum, anodized
Optical surface Glass Glass
Weight 66 g 155 g
Degree of protection per IEC 60529 IP 54 IP 54
Eye safety per IEC 62471 Extempt group Extempt group
Polarity reversal protected/Short-circuit protected Yes/Yes Yes/Yes
Ambient temperature range Ta –10...+55 °C –10...+55 °C
Storage temperature range –25...+75 °C –25...+75 °C

Light accessories see page 309 for connec-


tors, and page 326 for information on mounting
brackets for direct assembly or compatible with
Balluff BMS mounting system.

Background light: With the through beam met-


hod, the background lighting is positioned behind
the object you wish to detect. The Vision Sensor
only detects the outline of the object based on this
position and allows you to monitor part dimensi-
ons or shapes extremely easily. Extraneous light
also poses no problems. Changes in the surface
(markings, color, etc.) can be suppressed almost
completely and have no influence on the test
result. Our background lights are particularly bright
and versatile. You can also use them as subtle in-
cident lights to illuminate highly reflective compo-
nents. Due to the extremely flat design, they are
ideal for use in applications with limited space.
Accessories − A Selection
Background lights

BAE LX-VS BAE LX-VS BAE LX-VS


Background light Background light Background light
Infrared Red light Infrared
BAE00KR BAE000H BAE00FR
BAE LX-VS-HI050 BAE LX-VS-HR100 BAE LX-VS-HI100
24 V DC 24 V DC 24 V DC
350 mA 400 mA 625 mA
Yes Yes Yes
50×50 mm 100×100 mm 100×100 mm
LED, infrared LED, red light LED, infrared
875 nm 617 nm 875 nm
105×80×9.5 mm 155×130×9.5 mm 155×130×9.5 mm
M4 screws M4 screws M4 screws
M12 connector, 4-pin M12 connector, 4-pin M12 connector, 4-pin
Aluminum, anodized Aluminum, anodized Aluminum, anodized
Glass Glass Glass
155 g 345 g 345 g
IP 54 IP 54 IP 54
Risk group 1 Extempt group Risk group 1
Yes/Yes Yes/Yes Yes/Yes
–10...+55 °C –10...+55 °C –10...+55 °C
–25...+75 °C –25...+75 °C –25...+75 °C

9.5 9.5

Accessories −
A Selection
BIS
Industrial RFID
accessories
BVS
Vision Sensors
accessories
BAE
Lights for
Vision Sensors
Power supplies

■ www.balluff.com 335
Accessories − A Selection
Background lights

Series BAE LX-VS BAE LX-VS


Style Background light Background light
Light type Red light Infrared
Ordering code BAE00C5 BAE00KP
Part number BAE LX-VS-HR150 BAE LX-VS-HI150
Supply voltage UB 24 V DC 24 V DC
Operating current 500 mA 800 mA
Trigger Yes Yes
Light field size 150×100 mm 150×100 mm
Emitter, light type LED, red light LED, infrared
Wavelength 617 nm 875 nm
Dimension 205×130×9.5 mm 205×130×9.5 mm
Attachment M4 screws M4 screws
Connection M12 connector, 4-pin M12 connector, 4-pin
Housing material Aluminum, anodized Aluminum, anodized
Optical surface Glass Glass
Weight 435 g 435 g
Degree of protection per IEC 60529 IP 54 IP 54
Eye safety per IEC 62471 Extempt group Risk group 1
Polarity reversal protected/Short-circuit protected Yes/Yes Yes/Yes
Ambient temperature range Ta –10...+55 °C –10...+55 °C
Storage temperature range –25...+75 °C –25...+75 °C

Light accessories see page 309 for connec-


tors, and page 326 for information on mounting
brackets for direct assembly or compatible with
Balluff BMS mounting system.

Background light: With the through beam met-


hod, the background lighting is positioned behind
the object you wish to detect. The Vision Sensor
only detects the outline of the object based on this
position and allows you to monitor part dimensi-
ons or shapes extremely easily. Extraneous light
also poses no problems. Changes in the surface
(markings, color, etc.) can be suppressed almost
completely and have no influence on the test
result. Our background lights are particularly bright
and versatile. You can also use them as subtle in-
cident lights to illuminate highly reflective compo-
nents. Due to the extremely flat design, they are
ideal for use in applications with limited space.

336
Accessories − A Selection
Background lights

IP69K

BAE LX-VS BAE LX-VS BAE LX-VS


Background light Background light Background light IP 69K
Red light Infrared Red light
BAE00JC BAE00JE BAE00JF
BAE LX-VS-HR200 BAE LX-VS-HI200 BAE LX-VS-HR100-E
24 V DC 24 V DC 24 V DC
800 mA 625 mA 400 mA
Yes Yes Yes
200×150 mm 200×150 mm 100×100 mm
LED, red light LED, infrared LED, red light
617 nm 875 nm 617 nm
255×180×9.5 mm 255×180×9.5 mm 155×130×9.5 mm
M4 screws M4 screws M4 screws
M12 connector, 4-pin M12 connector, 4-pin M12 connector, 4-pin
Aluminum, anodized Aluminum, anodized Stainless steel
Glass Glass Glass
730 g 730 g 350 g
IP 54 IP 54 IP 69K
Extempt group Risk group 1 Extempt group
Yes/Yes Yes/Yes Yes/Yes
–10...+55 °C –10...+55 °C –10...+55 °C
–25...+75 °C –25...+75 °C –25...+75 °C

11.5

Accessories −
A Selection
BIS
Industrial RFID
accessories
BVS
Vision Sensors
accessories
BAE
Lights for
Vision Sensors
Power supplies

■ www.balluff.com 337
Accessories − A Selection
Ring lights

SlimLine

Series BAE LX-VS BAE LX-VS


Style Ring light Standard Ring light SlimLight
Light type Red light Red light
Ordering code BAE000J BAE00FP
Part number BAE LX-VS-RR100 BAE LX-VS-RR100-S
Supply voltage UB 24 V DC 24 V DC
Operating current Normal 800 mA 600 mA
Boost 1300 mA
Trigger Yes Yes
Mode Normal Yes Yes
Boost Yes
Light field size Ø 100/60 mm Ø 100/93 mm
Emitter, light type LED, red light LED, red light
Wavelength 617 nm 617 nm
Dimension Ø 116×20.5 mm Ø 116×20.5 mm
Attachment M4 screws M4 screws
Connection M12 connector, 4-pin M12 connector, 4-pin
Housing material Aluminum, anodized Aluminum, anodized
Optical surface Glass Glass
Weight 360 g 345 g
Degree of protection per IEC 60529 IP 65 IP 54
Eye safety per IEC 62471 Normal Extempt group Extempt group
Boost Extempt group
Polarity reversal protected/short-circuit protected Yes/Yes Yes/Yes
Ambient temperature range Ta –10...+55 °C –10...+55 °C
Storage temperature range –25...+75 °C –25...+75 °C

Light accessories see page 309 for connectors, and page 326 for
information on mounting brackets for direct assembly or compatible with
Balluff BMS mounting system.

Ring lights are used as additional incident lights. The design of the light and
powerful integral LEDs ensure virtually shadow free illumination with a high
degree of intensity. Ring lights are particularly suited to applications where the
distance between the BVS and the detected object is greater than 300 mm.
Due to the high intensity of the light generated, these lights can also be used
to suppress influences from changing ambient light. The ring light can be fitted
and aligned together with the Vision Sensor using our mounting bracket speci-
ally adapted to the Balluff Mounting System. As an accessory, we offer diffuser
attachments that prevent strong reflections on shiny components, for example.

The diffuser attachment ensures even light without disturbing ref-


lections in applications with reflective surfaces. The diffuser is made
of high-quality glass and can be installed directly on the light.

Description Diffuser attachment


Version for ring lights
Ordering code BAM01A7
Part number BAM OF-VS-001-D-RX100

338
Accessories − A Selection
Ring lights

SlimLine SlimLine

BAE LX-VS BAE LX-VS BAE LX-VS BAE LX-VS


Ring light Standard Ring light SlimLight Ring light Standard Ring light SlimLight
Infrared Infrared White light White light
BAE000K BAE00FN BAE00AN BAE00FM
BAE LX-VS-RI100 BAE LX-VS-RI100-S BAE LX-VS-RW100 BAE LX-VS-RW100-S
24 V DC 24 V DC 24 V DC 24 V DC
600 mA 500 mA 700 mA 450 mA
1300 mA 1200 mA
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes
Ø 100/60 mm Ø 100/93 mm Ø 100/60 mm Ø 100/93 mm
LED, infrared LED, infrared LED, white light LED, white light
875 nm 875 nm
Ø 116×20.5 mm Ø 116×20.5 mm Ø 116×20.5 mm Ø 116×20.5 mm
M4 screws M4 screws M4 screws M4 screws
M12 connector, 4-pin M12 connector, 4-pin M12 connector, 4-pin M12 connector, 4-pin
Anodized aluminum Aluminum, anodized Anodized aluminum Aluminum, anodized
Glass Glass Glass Glass
360 g 345 g 360 g 345 g
IP 65 IP 54 IP 65 IP 54
Risk group 1 Risk group 1 Extempt group Extempt group
Risk group 1 Extempt group
Yes/Yes Yes/Yes Yes/Yes Yes/Yes
–10...+55 °C –10...+55 °C –10...+55 °C –10...+55 °C
–25...+75 °C –25...+75 °C –25...+75 °C –25...+75 °C

Accessories −
A Selection
BIS
Industrial RFID
accessories
BVS
Vision Sensors
accessories
BAE
Lights for
Vision Sensors
Power supplies
Diffuser attachment

■ www.balluff.com 339
Accessories − A Selection
Line lights

Light field 85 mm Light field 170 mm

Series BAE LX-VS BAE LX-VS


Style Line light Line light
Light type Red light Red light
Ordering code BAE00AP BAE00AZ
Part number BAE LX-VS-LR085 BAE LX-VS-LR170
Supply voltage UB 24 V DC 24 V DC
Operating current Normal 200 mA 375 mA
Boost 375 mA 750 mA
Trigger Yes Yes
Mode Normal Yes Yes
Boost Yes Yes
Light field size 10×79 mm 10×170 mm
Emitter, light type LED, red light LED, red light
Wavelength 617 nm 617 nm
Dimension 113.5×13×18 mm 197.5×13×18 mm
Attachment M4 screws M4 screws
Connection M12 connector, 4-pin M12 connector, 4-pin
Housing material Anodized aluminum Anodized aluminum
Optical surface Glass Glass
Weight 80 g 110 g
Degree of protection per IEC 60529 IP 54 IP 54
Eye safety per IEC 62471 Normal Extempt group Extempt group
Boost Extempt group Extempt group
Polarity reversal protected/Short-circuit protected Yes/Yes Yes/Yes
Ambient temperature range Ta –10...+55 °C –10...+55 °C
Storage temperature range –25...+75 °C –25...+75 °C

Light accessories see page 309 for connectors, and page 326 for
information on mounting brackets for direct assembly or compatible with
Balluff BMS mounting system.

Line light generate specific homogeneous lighting that brightens the image
area directly. When used for lateral illumination, the light can generate subtle
reflections and shadows. The subtle reflection generates an even illumination
pattern without shiny areas. The shadows generated allow you to check the
presence or absence of features on the object more easily.

The line lights can illuminate rectangular areas right up to the


corners. Shadows can also be generated in grooves and along
edges and then used for evaluation purposes.

340
Accessories − A Selection
Line lights

Light field 85 mm Light field 170 mm Light field 85 mm Light field 170 mm

BAE LX-VS BAE LX-VS BAE LX-VS BAE LX-VS


Line light Line light Line light Line light
Infrared Infrared White light White light
BAE00AT BAE00AY BAE00AR BAE00AW
BAE LX-VS-LI085 BAE LX-VS-LI170 BAE LX-VS-LW085 BAE LX-VS-LW170
24 V DC 24 V DC 24 V DC 24 V DC
200 mA 375 mA 200 mA 300 mA
375 mA 750 mA 375 mA 500 mA
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
10×71 mm 10×170 mm 10×83 mm 10×170 mm
LED, infrared LED, infrared LED, white light LED, white light
875 nm 875 nm
113.5×13×18 mm 197.5×13×18 mm 113.5×13×18 mm 197.5×13×18 mm
M4 screws M4 screws M4 screws M4 screws
M12 connector, 4-pin M12 connector, 4-pin M12 connector, 4-pin M12 connector, 4-pin
Anodized aluminum Anodized aluminum Anodized aluminum Anodized aluminum
Glass Glass Glass Glass
80 g 110 g 80 g 110 g
IP 54 IP 54 IP 54 IP 54
Extempt group Extempt group Extempt group Extempt group
Risk group 1 Risk group 1 Extempt group Extempt group
Yes/Yes Yes/Yes Yes/Yes Yes/Yes
–10...+55 °C –10...+55 °C –10...+55 °C –10...+55 °C
–25...+75 °C –25...+75 °C –25...+75 °C –25...+75 °C

Accessories −
A Selection
BIS
Industrial RFID
accessories
BVS
Vision Sensors
accessories
BAE
Lights for
Vision Sensors
Power supplies

Ø 2.3
both sides 6×3
lowered (2×)

■ www.balluff.com 341
Series BAE LX-VS
Style Spotlight
Light type Red light
Ordering code BAE00KF
Part number BAE LX-VS-SR012
Supply voltage UB 24 V DC
Operating current 70 mA
Trigger
Light field size Ø 12 mm
Emitter, light type LED, red light
Wavelength 617 nm
Dimension M12×32.5 mm
Attachment M12×1 nut
Connection M12 connector, 4-pin
Housing material Stainless steel
Weight 45 g
Degree of protection per IEC 60529 IP 67
Eye safety per IEC 62471 Extempt group
Polarity reversal protected/short-circuit protected Yes/Yes
Ambient temperature range Ta –10...+50 °C
Storage temperature range –10...+60 °C

Light accessories see page 309 for connectors, and page 326 for
information on mounting brackets for direct assembly or compatible with
Balluff BMS mounting system.

Spotlight: A spotlight is perfect for the precision illumination of specific areas.


Greater inspection distances can be implemented if a spotlight is used. Unlike
ring lights, spotlights can be attached in any position. You can swivel the light
towards the area that you wish to illuminate.

342
Accessories − A Selection
Spotlights

BAE LX-VS BAE LX-VS BAE LX-VS BAE LX-VS


Spotlight Spotlight Spotlight Spotlight
Red light Infrared Red light Infrared
BAE00H0 BAE00H1 BAE00FT BAE00H2
BAE LX-VS-SR018 BAE LX-VS-SI018 BAE LX-VS-SR030 BAE LX-VS-SI030
24 V DC 24 V DC 24 V DC 24 V DC
85 mA 85 mA 120 mA 115 mA
Yes Yes Yes Yes
Ø 18 mm Ø 18 mm Ø 30 mm Ø 30 mm
LED, red light LED, infrared LED, red light LED, infrared
617 nm 850 nm 617 nm 850 nm
M18×72 mm M18×72 mm M30×62 mm M30×62 mm
M18×1 nut M18×1 nut M30×1.5 nut M30×1.5 nut
M12 connector, 4-pin M12 connector, 4-pin M12 connector, 4-pin M12 connector, 4-pin
Stainless steel Stainless steel Stainless steel Stainless steel
75 g 75 g 90 g 90 g
IP 67 IP 67 IP 67 IP 67
Extempt group Risk group 1 Extempt group Risk group 1
Yes/Yes Yes/Yes Yes/Yes Yes/Yes
0...+50 °C 0...+50 °C 0...+50 °C 0...+50 °C
–10...+60 °C –10...+60 °C –10...+60 °C –10...+60 °C

Accessories −
A Selection
BIS
Industrial RFID
accessories
BVS
Vision Sensors
accessories
BAE
Lights for
Vision Sensors
Power supplies

■ www.balluff.com 343
Accessories − A Selection
Coaxial lights

■ Long service life


■ Uniform lighting
■ High standard of quality
■ Energy-saving LED technology

Coaxial lighting is the optimal solution for lighting highly reflective


surfaces. Therefore, coaxial lighting is well suited for transmitted
light inspections of colored materials and for inspections of printed
or dirty surfaces. It is low maintenance, industrially sound and thus
can be integrated with low effort.

344
Accessories − A Selection
Coaxial lights

Series BAE LX-VS BAE LX-VS


Style Coaxial light Coaxial light
Light type Red light Red light
Ordering code BAE00J9 BAE00JA
Part number BAE LX-VS-OR50 BAE LX-VS-OR100
Supply voltage UB 24 V DC 24 V DC
Operating current 218 mA 600 mA
Light field size 50×50 mm 100×100 mm
Emitter, light type LED, red light LED, red light
Wavelength 630 nm 630 nm
Dimension 106×67×57 mm 150×108×110 mm
Attachment M4 screws M4 screws
Connection M8 connector, 2-pin M8 connector, 2-pin
Housing material Anodized aluminum Anodized aluminum
Optical surface Glass Glass
Weight 450 g 1500 g
Degree of protection per IEC 60529 IP 54 IP 54
Eye safety per IEC 62471 Extempt group Extempt group
Polarity reversal protected/short-circuit protected Yes/Yes Yes/Yes
Ambient temperature range Ta –10…+55 °C –10…+55 °C
Storage temperature –25…+75 °C –25…+75 °C

Light accessories see page 309 for connectors,


and page 326 for information on mounting brackets
for direct assembly or compatible with Balluff BMS
mounting system.

Coaxial lighting is used if the industrial image


processing system requires diffused light to, Accessories −
A Selection
for example, uniformly illuminate highly reflective
surfaces and prevent reflection. BIS
Industrial RFID
accessories
BVS
Vision Sensors
accessories
BAE
Lights for
Vision Sensors
Power supplies

■ www.balluff.com 345
Accessories − A Selection
Dark field illumination

Series BAE LX-VS


Style Dark field illumination
Light type Red light
Ordering code BAE00AM
Part number BAE LX-VS-DR090
Supply voltage UB 24 V DC
Operating current 425 mA
Trigger Yes
Light field size Ø 90 mm
Emitter, light type LED, red light
Wavelength 617 nm
Dimension 105×80×9.5 mm
Attachment M4 screws
Connection M12 connector, 4-pin
Housing material Anodized aluminum
Optical surface PMMA
Weight 250 g
Degree of protection per IEC 60529 IP 54
Eye safety per IEC 62471 Extempt group
Polarity reversal protected/short-circuit protected Yes/Yes
Ambient temperature range Ta –10...+55 °C
Storage temperature range –25...+75 °C

Light accessories see page 309 for connectors, and page 326 for
information on mounting brackets for direct assembly or compatible with
Balluff BMS mounting system.

Dark field illumination: The dark field light allows you to illuminate
and identify scratches, dents and impurities on surfaces extremely well.
The dark field light must be attached to the detection object at a distance
of 10…20 mm so that the surfaces on the component can be inspected.
If the diameter of the dark field is insufficient, two or more line lights can
also be installed to implement this type of illumination.

The dark field light allows you to illuminate surfaces in order


to clearly reveal indentations or scratches, so that they can be
inspected quickly and reliably.

346
6
Accessories − A Selection
Line Laser

Series BAE LX-XO BAE LX-XO


Style Line laser Line laser
Light Type Red light Red light
Ordering code BAE00KE BAE00KZ
Part number BAE LX-XO-PL018-L1-S4 BAE LX-XO-PL018-L2-S4
Supply voltage UB 5...30 V DC 5...30 V DC
Operating current 30 mA 30 mA
Trigger Yes Yes
Light field width 100 mm distance 73 μm/82 mm 77 μm/30 mm
and length 500 mm distance 170 μm/420 mm 107 μm/60 mm
1000 mm distance 320 μm/840 mm 189 μm/300 mm
2000 mm distance 677 μm/1650 mm 360 μm/600 mm
Emitter, light type Laser, red light Laser, red light
Wavelength 640 nm 635 nm
Dimension Ø 20×128 mm Ø 20×108 mm
Connection M12 connector, 4-pin M12 connector, 4-pin
Housing material Brass, coated and aluminum, anodized Brass, coated and aluminum, anodized
Optical surface Glass Glass
Weight 66 g 56 g
Degree of protection per IEC 60529 IP 67 IP 67
Laser class üer IEC 60825-1 2M 1M
Polarity reversal/short-circuit protected Yes/Yes Yes/Yes
Ambient temperature Ta –10…+50 °C –10…+50 °C
Storage temperature –10…+80 °C –10…+80 °C

Light accessories see page 309 for connectors, 20 20


and page 322 for information on mounting brackets
for direct assembly or compatible with Balluff BMS
mounting system.
61

61

Caution Accessories −
Do not observe laser radiation directly with A Selection
optical instruments (magnifiers, microscopes, etc.)
93

BIS
Laser class 1M and 2M (DIN EN 60825-1: 2008)
108

Industrial RFID
113

accessories
128

BVS
Vision Sensors
accessories
BAE
Lights for
Vision Sensors
Power supplies

M12×1
M18×1

M12×1
M18×1

Exceptional uniformity, focusable and a high standard of quality


Line lasers are used in industrial image processing and for aligning and positio-
ning workpieces or accessories. The combination of laser lighting and image
processing provides interesting options for automating visual quality control.
They are used in many ways for detecting and measuring defects, presence,
diameters, edges, gaps, steps, etc. Our line lasers with uniform output distri-
bution can be focused precisely without a tool and securely adjusted using a
locking device. The line position stays unchanged.

■ www.balluff.com 347
Accessories − A Selection
Standard power supplies

Every industrial automation system needs a reliable, clean, and ■ Ultra-reliable power supplies
controlled source of power without spikes. for protecting sensitive control electronics
Only then can these systems deliver the expected performance. With
the new Balluff power supplies you get what you expect and more. ■ Protection against unforeseen events
They ensure reliable power even under demanding conditions. They Integrated overload and overvoltage protection
fall in line with the long Balluff tradition of reliable and high-quality
performance products for industrial automation. ■ Wide selection of models
Whether stand-alone or an individual combination of various
models, these solutions are perfect for your requirements

■ Clean, precision power supply for particularly


complex systems
Load regulation ±1 % for all models, ripple & noise for most
models less than 50 mV

■ Long service life for less system downtime


MTBF (Mean Time Between Failure) up to 800,000 hours/91 years

Ready output
Notifies the control system
that the power supply is ready
(included with most models)

Parallel/Single mode
If more power is required,
multiple units can be combi-
ned in parallel (most models)

Rugged
DIN rail mounting

Adjustable output
The output voltage can be
adjusted to compensate
for losses from cabling and
distributed components
CE, UL/cUL
and TÜV
Approvals

Status indicator
LED for DC ON and DC LO
indicator (most models)

IP 20 metal housing
(most models)
Terminals with
contact protection
No additional protection
necessary

348
Accessories − A Selection
Standard power supplies

Output power Features Product information

Housing material

Ordering code
Output voltage

3.8 A/91.20 W

Parallel mode
Ready output
Input voltage
0.75 A/18 W
1.25 A/30 W

2.5 A/120 W

Part number
10 A/120 W
10 A/240 W
10 A/480 W
20 A/480 W
40 A/960 W
1.5 A/18 W
2.5 A/30 W
2.5 A/60 W

5 A/120 W
5 A/240 W
5 A/60 W
Version

■ Single-phase1 Plastic BAE0036 BAE-PS-XA-1W-12-015-001


■ ■ BAE0039
12 V

Single-phase1 Plastic BAE-PS-XA-1W-12-025-002


■ Single-phase1 Metal ■ BAE003E BAE-PS-XA-1W-12-050-002
■ Single-phase2 Metal ■ ■ BAE003H BAE-PS-XA-1W-12-100-003
■ Single-phase1 Plastic BAE0001 BAE-PS-XA-1W-24-007-001
■ Single-phase1 Plastic ■ BAE0004 BAE-PS-XA-1W-24-012-002
■ Single-phase1 Plastic ■ BAE0005 BAE-PS-XA-1W-24-025-002
Standard IP 20

■ Single-phase2 Metal ■ ■ BAE003J BAE-PS-XA-1W-24-038-003


■ Single-phase2 Metal ■ ■ BAE0006 BAE-PS-XA-1W-24-050-003
24 V

■ Single-phase2 Metal ■ ■ BAE0002 BAE-PS-XA-1W-24-100-004


■ Single-phase2 Metal ■ ■ BAE0003 BAE-PS-XA-1W-24-200-005
■ 3-phase3 Metal ■ BAE0007 BAE-PS-XA-3Y-24-050-009
■ 3-phase3 Metal ■ ■ BAE0008 BAE-PS-XA-3Y-24-100-006
■ 3-phase3 Metal ■ ■ BAE0009 BAE-PS-XA-3Y-24-200-007
■ 3-phase3 Metal ■ ■ BAE003R BAE-PS-XA-3Y-24-400-010
■ Single-phase2 Plastic ■ ■ BAE003K BAE-PS-XA-1W-48-025-003
48 V

■ Single-phase2 Metal ■ ■ BAE003L BAE-PS-XA-1W-48-050-004


■ Single-phase2 Metal ■ ■ BAE003M BAE-PS-XA-1W-48-100-005

1
= 100...240 V AC
2
= 115/230 V AC (Auto-Select)
3
= 340...575 V AC

Power for controllers and networks


Specially designed for control devices, Balluff power supplies offer
you the certainty of being able to perfectly integrate them into your
control package.

The PS series of ultra-reliable power supply units is available in a


wide range of 12, 24, and 48 V DC models with single or 3-phase
input. With a bandwidth of 18 W to 960 W, they truly leave nothing
to be desired. If you need even more power, connect multiple power
supplies together in parallel for greater capacity.
If you need other voltage levels, simply contact us. Accessories −
A Selection
BIS
Industrial RFID
accessories
BVS
Vision Sensors
accessories
BAE
Lights for
Vision Sensors
Power supplies

Trouble-free installation
Reliable power has never been so simple to install. Starting with the
convenient mounting of DIN rails using the integrated Balluff high-
performance mounting system. The screw terminals are aligned to
enable the integration of an AC input from below and a DC output
from above. Connections with contact protection render additional
safety equipment superfluous.

■ www.balluff.com 349
Accessories − A Selection
Intelligent power supplies

Intelligent power supply units from Balluff General key information about the IP 20 and IP 67
The installation of local power supply units without switch cabinets power supply units
with the IP 67 degree of protection is becoming more popular in ■ High efficiency of 92 %
industrial automation. Although local power supply units are already ■ Minimal heat loss and generation
available, they are generally difficult to access once installed. To ■ Increasing efficiency of the systems
further complicate matters, it is practically impossible to monitor the ■ 3-stage status indication
operating state. As a result, operators rely on preventive maintenan- ■ Power boost (150 % for 4 sec.)
ce concepts to guarantee maximum possible availability. This proce- ■ Extremely compact
dure is reliable, but also expensive, because devices are frequently ■ More efficient utilization of the power supply units
replaced during the maintenance cycle well before the end of their ■ Planned reserves are not wasted
service life, as there is no alternative system available. ■ Prevention of failures caused by continuous overload
■ Scheduled maintenance and repairs no longer necessary
For the first time, intelligent, energy-saving power supply units from ■ Higher productivity
Balluff promise to remedy this situation. Their condition is visualized ■ PSU replaced only at the end of its service life
by means of optical indicators. ■ Service life of 15 years (at 80 % load and 40 °C),
MTBF > 800,000 h
This novel concept allows detection of the condition of the device at ■ Enclosed housing guarantees high degree of resistance to
a glance. Since it tracks dynamic loads, it can be operated continu- vibration and shock loads
ously even under high load conditions. This makes typical reserves ■ With IP 20, also with potential-free alarm contacts
of 30 to 50 % superfluous.
Ideal areas of application for these intelligent power supply units
This intelligence forms the basis of a new intelligent generation of include local installations in the automobile industry, machine cons-
power supply units that can be continuously utilized at full capacity truction, wind turbines, etc.
and provides visual information about the internal status via the:
■ Load level
■ Stress level
■ Lifetime
IP 20
The displays provide an easy way for the operator to quickly ascer-
tain the status.

One special feature is that the three-phase intermediate transformer


that is usually installed in wind turbines can be omitted. That saves
money. A large input voltage range of 380...690 V allows the primary
switching power supply to be connected directly to the generator
voltage on the wind turbine and then operated normally.

IP 67

Please find more detailed information


in our Industrial Networking and Connectivity
catalog or online.

350
Accessories − A Selection
Intelligent power supplies

Load level: Heartbeat: Wear indicator:

Load level Stress level Lifetime


Reversible in short term Reversible in medium term Irreversible in long term

Load level indicates the current Stress level indicates the physi- Lifetime indicates the remaining All indicators are multi-
load on the device. The display cal and thermal loads. Changing useful life of the device, and is colored—green, yellow, or
indicates the load without delay. the load has an effect on device based on the sum of all loads. red—and show the status
wear. of the device.

Degree of protection as per IEC 60529 IP 20 IP 67


Output current 5 A and 10 A 3.8 A and 8 A
Output power 120 W and 240 W 91.2 W and 192 W
Output voltage 24 V DC (SELV) 24 V DC (SELV/PELV)
Input voltage 100...240 V AC 100...240 V AC
Single phase Single phase
5 A/120 W Isolated output Ordering code BAE00EK
Single phase (4-pin), SELV Part number BAE PS-XA-1W-24-050-013
10 A/240 W Isolated output Ordering code BAE00EU
Single phase (4-pin), SELV Part number BAE PS-XA-1W-24-100-014
3.8 A/91.2 W Isolated output Ordering code BAE00EN
Single phase (4-pin), SELV Part number BAE PS-XA-1W-24-038-601
3.8 A/91.2 W Grounded output Ordering code BAE00EP
Single phase (4-pin), PELV Part number BAE PS-XA-1W-24-038-602
3.8 A/91.2 W Isolated output Ordering code BAE00ER
Single phase (5-pin), SELV Part number BAE PS-XA-1W-24-038-603
3.8 A/91.2 W Isolated output Ordering code BAE00FW
Single phase (4-pin), SELV Part number BAE PS-XA-1W-24-038-607 Accessories −
A Selection
8 A/192 W Isolated output Ordering code BAE00ET BIS
Single phase (4-pin), SELV Part number BAE PS-XA-1W-24-080-604 Industrial RFID
accessories
8 A/192 W Isolated output Ordering code BAE00FL
BVS
Single phase (5-pin), SELV Part number BAE PS-XA-1W-24-080-605 Vision Sensors
8 A/192 W Grounded output Ordering code BAE00FY accessories
Single phase (4-pin), PELV Part number BAE PS-XA-1W-24-080-606 BAE
Lights for
Efficiency High efficiency, typically > 92 % High efficiency, typically > 91 % Vision Sensors
MTBF > 800,000 h > 800,000 h Power supplies
Input Screwed contact 7/8", 3-pin
Output Screwed contact 7/8", 4-pin (socket)
Potential-free alarm fitting for Ethernet/IP,
contacts for DC alarm DeviceNet
and lifetime 7/8", 5-pin (socket)
fitting for CC-Link,
Profinet, Profibus
Operating temperature –25...+70 °C –25...+70 °C
Storage temperature −40...+80 °C −40...+80 °C
Fasteners DIN rail mounting Panel, wall, and
field mounting
Housing material Metal, semi-potted Metal, fully potted
Service life (at 80 % load and 40 °C) 15 years 15 years
Warranty 2 years 2 years

■ www.balluff.com 351
Basic
Information
and
Definitions

UID_SPS z UID_Tag <<not OK>>

UID_SPS = UID_Tag <<OK>>

352
Basic Information and Definitions
Contents

General information 354


Mechanical properties 356
Quality 357

Electro-magnetic identification
BIS U Industrial RFID System 358

Inductive identification
BIS M Industrial RFID System 360
BIS C Industrial RFID System 364
BIS L Industrial RFID System 370
BIS S Industrial RFID System 374
Interaction between read/write heads and data carriers 376

Vision-based identification
BVS Vision Sensors 378

■ www.balluff.com 353
Basic Information and Definitions
General information

Standards

Protection class II [ EN 60947-5-2/IEC 60947-5-2

Degree of protection IP 60...67 EN 60529/IEC 60529


IP 68 per BWN Pr. 20 Balluff factory standard (BWN): Temperature
storage 48 h at 60 °C, 8 temperature cycles
according to EN 60068-2-14/IEC 60068-2-14
between the benchmark temperatures accor-
ding to the data sheet, 1 h storage in water,
insulation inspection, 24 h storage in water,
insulation test, 8 temperature cycles according
to EN 60068-2-14 IEC 60068-2-14 between the
benchmark temperatures according to the data
sheet, 7 days storage in water, insulation test.

IP 68 per BWN Pr. 27 Balluff Factory Standard (BWN):


Testing products for use in the foods industry.
IP 69K DIN 40050 part 9: Protection against
entry of water under high pressure- or
steam jet cleaning.

EMC (Electromagnetic Emissions, RF noise voltage and EN 55011


Compatibility) RF noise radiation from electrical equipment
Interference immunity against discharging EN 61000-4-2/IEC 61000-4-2
static electricity (ESD)
Radio frequency immunity against EN 61000-4-3/IEC 61000-4-3
high-frequency electromagnetic fields (RFI)
Immunity to fast transients (bursts) EN 61000-4-4/IEC 61000-4-4
Interference immunity against conducted EN 61000-4-6/IEC 61000-4-6
interference, induced by high-frequency fields
Immunity to voltage dips and voltage interruptions EN 61000-4-11/IEC 61000-4-11
Surge-voltage stability EN 60947-5-2/IEC 60947-5-2

Environmental simulation Vibration, sinusoidal EN 60068-2-6/IEC 60068-2-6


Shock EN 60068-2-27/IEC 60068-2-27
Continuous shock EN 60068-2-29/IEC 60068-2-29

354
Basic Information and Definitions
General information

Mounting torques The following torques are to be followed so that the sensors are
not mechanically destroyed during installation, as long as no other
information is indicated on the data sheet or the sensor packaging.

Size Material Tightening torque


M12×1 Stainless steel 40 Nm
M18×1 PBT 1 Nm
M18×1 Stainless steel 60 Nm
M30×1.5 PBT 3 Nm
M30×1.5 Stainless steel 90 Nm

Degree of protection The degrees of protection are First digit: Second digit:
given according to IEC 60529. 2 Protection against penetration 0 No special protection
Code letters IP (International of solid bodies larger than 4 Protection against water,
Protection) designate protection 12 mm, shielding from fingers which is sprayed
for electrical equipment against and objects from all directions against
shock hazard, ingress of solid 4 Protection against penetration the equipment
foreign bodies and water. of solid bodies larger than 5 Protection against a stream
1 mm, shielding from tools of water from a nozzle which
and wires hits the equipment from all
5 Protection against damaging directions
dust deposits, complete 7 Protection against water,
contact protection if the equipment (housing)
6 Protection against penetration is temporarily submerged
of dust, complete contact 8 Protection against water
protection when submerged for some
time

Basic
Information
and Definitions
General
information
Mechanical
properties
Quality
BIS U
BIS M
BIS C
BIS L
BIS S
Interaction
between
read/write
heads and
data carriers
BVS

■ www.balluff.com 355
Basic Information and Definitions
Mechanical properties

Materials

Material Use and characteristics


Plastics
ABS Acrylonitrile-Butadiene-Styrene Impact-resistant, stiff, limited chemical resistance.
Some types flame-retardant. Used for housings.

ASA Acrylonitrile styrene acrylate Impact-resistant material, scratch-resistant surface and good weather resistance

EP Epoxy resin Duromer, molded plastic material, highest mechanical strength and temperature resistance.
Very good dimensional stability. Cannot be melted.

Epoxy resin - hollow glass spheres Hollow glass spheres can be treated with epoxy resins. They are used for manufacturing
converters with low thickness and high pressure rating.

PA Polyamide High impact resistance, good chemical resistance.

PA 6, PA 66, PA mod., PA 12 Polyamide Good mechanical strength. Temperature resistance.


PA 12 approved for food industry applications.

PBT Polybutylene terephtalate High mechanical strength and temperature resistance. Some types flame-retardant.
Good chemical resistance. Good oil resistance.

PC Polycarbonate Clear, hard, elastic and impact resistant. Good temperature resistance.
Limited chemical resistance.

PET Polyethylene terephtalate High resistance to breakage, good dimensional stability.


Frequently used in the food industry.

POM Polyoxymethylene High impact resistance, good mechanical strength. Good chemical resistance.

Plastics
PPS Polyphenylene sulfide High strength, even at high temperatures. High chemical resistance.

PVC Polyvinyl chloride Good mechanical strength and chemical resistance (cable).

PVDF Polyvinylidene fluoride Thermoplastic. High mechanical strength and temperature resistance.
Good chemical resistance (similar to PTFE).

Metal
Wrought aluminum alloy Standard-aluminum for machined cutting. Can be anodized.
Used for housings and mounting components.

CuZn Brass Standard-housing material with surface protection.

Stainless steel Excellent corrosion resistance and strength. Quality 1.4034, 1.4104:
Standard-material; quality 1.4305, 1.4301: Standard-material for the food
industry; quality 1.4401, 1.4404, 1.4571: With increased requirements on chemical
resistance at elevated temperatures for the food industry.

GD-Al die-cast aluminum Low specific gravity. Good strength and resistance.
Some types can be anodized.

GD-Zn die-cast zinc Good resistance and strength. Usually with protective surface coating.

Other
Glass Good chemical resistance and strength. Used primarily in optical applications
(lenses, cover lenses).

356
Basic Information and Definitions
Quality

Quality and the environment

Quality management system Balluff companies


per DIN EN ISO 9001:2008 Balluff GmbH Germany
Balluff SIE Sensorik GmbH Germany
Balluff Controles Elétricos Ltda. Brazil
Balluff Sensors (Chengdu) Co., Ltd. China
Balluff Ltd. Great Britain
Balluff Automation S.R.L. Italy
Balluff Canada Inc. Canada
Balluff de México S.A. de C.V. Mexico
Balluff GmbH Austria
Balluff Sp. z o.o. Poland
Balluff Hy-Tech AG Switzerland
Balluff Sensortechnik AG Switzerland
Balluff S.L. Spain
Balluff CZ, s.r.o Czech Republic
Balluff Elektronika Kft. Hungary
Balluff Inc. USA

Environmental Balluff companies


management system per Balluff GmbH Germany
DIN EN ISO 14001:2009 Balluff Sensors (Chengdu) Co., Ltd. China
Balluff Elektronika KFT Hungary

Testing laboratory The Balluff testing laboratory operates in accordance with ISO/
IEC 17025 and is accredited by DAkks for testing electromagnetic
compatibility (EMC).

Balluff products comply with Products that require labeling are subject to a conformity evaluation
EU directives process according to the EU directive and the product is labeled
with the CE marking.
Balluff products fall under the following EU directive:

2004/108/EC EMC directive


2006/95/EC Low Voltage Directive valid for
products with supply voltage
≥ 75 V DC/≥ 50 V AC
Basic
Information
and Definitions
Product approvals Product approvals are awarded by domestic and international institu- General
tions. Their symbols affirm that our products meet the specifications information
of these institutions. Mechanical
properties
Quality
"US Safety System" and "Canadian Standards Association" BIS U
under the auspices of Underwriters Laboratories Inc. (cUL). BIS M
BIS C
BIS L
BIS S
Interaction
between
read/write
heads and
data carriers
BVS

■ www.balluff.com 357
Basic Information and Definitions
BIS U configuration software

Parameters are configured using the "BIS UHF Manager" software.


One requirement is that the processor is connected to the controlling
system. The parameter settings can be overwritten at any time. The
parameters can be saved in an XML file so that they can be retrieved
whenever needed.

Application software Balluff partners with only best in class software providers and elite
integrators to deliver the complete RFID solution. From a full system
rollout to meshing into the current process, our software partners
understand the needs of the manufacturing industry. Logistics, Work
in process (WIP) production control, E-Kanban etc., are just a few of
the applications in which our partners specialize.

Setting the transmission power and


dependency on the antenna being used

The BIS U-6027 processor and the controlling system


communicate via Ethernet. Assigning a unique IP address
associates the processor with a network.

358
Basic Information and Definitions
BIS U service

We assist you in finding a solution to your RFID task with short The solution design phase is concluded with a temporary test
decision paths and personal contacts – from design to implementati- setup on-site on the system. You thereby receive valuable informa-
on. The objectives and probability of success of your RFID identifica- tion for RFID use in your environment and are then able to perform
tion task are objectively analyzed and the system design refined. a realistic ROI assessment.
The RFID system components are then selected.

Step 1: Preanalysis Step 2: Feasibility Step 3: Solution suggestion Step 4: Project coaching
Description of the installation ■ Project description and ■ Preparation of samples ■ Control of system integrators
conditions and physical definition of objectives and test settings ■ Support in all launch phases
characteristics: ■ Type and characteristics ■ Testing of RFID technology ■ Project documentation
■ Mechanical installation of the solution in the actual environment and knowledge integration
■ Power limits ■ Where are the weak points ■ Performance comparison ■ User training
■ Ambient parameters ■ Selection of system of various applications
■ Detection type components We are happy to help!
■ Transponder types Tel. +49 7158 173-401
■ Stationary/mobile +49 7158 173-727
read/write devices E-mail: TecSupport@balluff.de

Basic
Information
and Definitions
General
information
Mechanical
properties
Quality
BIS U
BIS M
Mounting definitions Flush in steel BIS C
Active sensing surface can be flush mounted to surface of steel. BIS L
Consult part data sheet for additional information. BIS S
Interaction
Non-flush on steel between
Active sensing surface must be clear and not be surrounded by steel. read/write
heads and
Consult part data sheet and clear zone definitions for more information. data carriers
BVS
Non-metal
Total clearance zone from any kind of metal must be maintained.
Consult part data sheet and clear zone definitions for more information.
Consult technical support for other metal mounting options.

■ www.balluff.com 359
Basic Information and Definitions
BIS M installation notes

Mounting definitions Flush in steel


Active sensing surface can be flush mounted to surface of steel.
Consult part data sheet for additional information.
Non-flush on steel
Active sensing surface must be clear and not be surrounded by steel.
Consult part data sheet and clear zone definitions for more information.
Non-metal
Total clearance zone from any kind of metal must be maintained.
Consult part data sheet and clear zone definitions for more information.
Consult technical support for other metal mounting options.

Minimum distance between

BIS M-101-01/A,

BIS M-105-01/A,

BIS M-151-02/A,
BIS M-122-01/L,

BIS M-102-01/L,
BIS M-111-02/A

BIS M-105-02/A

BIS M-108-02/A

BIS M-150-02/A
BIS M-122-02/L

BIS M-110-02/L

BIS M-112-02/L

BIS M-120-01/L
two data carriers

BIS M-300 > 100 > 100 > 150 > 100 > 100
BIS M-301 > 200 > 200 > 200 > 100 > 200 > 250
BIS M-302, BIS VM-307 > 100 > 100 > 100 > 100 > 100 > 100
BIS M-304 > 100 > 100 > 100 > 100 > 100 > 100
BIS M-400-007-001-00-S115 > 100 > 100 > 150 > 100 > 100
BIS M-401-007-001-00-S115 > 200 > 200 > 200 > 100 > 200 > 250
BIS M-400-007-002-00-S115 > 100 > 100 > 100 > 100 > 100 > 100
BIS M-351, BIS VM-351 > 250
BIS M-451-007-001-00-S115 > 250
Dimensions in mm

Minimum distance between BIS M-300 200


two read/write heads BIS M-301 600
BIS M-351/BIS VM-351 600
BIS M-302/BIS VM-307 100
BIS M-304 100
BIS M-400-007-001-00-S115 200
BIS M-401-007-001-00-S115 600
BIS M-451-007-001-00-S115 600
BIS M-400-007-002-00-S115 100
BIS M-410-007-002-00-S115 200
BIS M-411-007-002-00-S115 300
Dimensions in mm

360
Basic Information and Definitions
BIS M installation notes

Mounting the read/write If the read/write heads are mounted so that they are joined through
heads on metal frames an enclosed metal frame, mutual interference may result (conductor
loop). This may reduce the read/write distances. The smaller the
read/write head, the less the interference. This may result in a reduc-
tion of the maximum distance by 80 %. In such a case you should
test the actual effective read distance.

Read/write head Metal frame

Clear zone dimensions For compliance to the read/write distances as rated for a given data
for read/write heads carrier to read/write head, the following Clear Zone Dimension must
be used for a non-metal data carrier mounting:
BIS M-105-02/A,

BIS M-150-02/A,
BIS M-111-02/L,

BIS M-112-02/L,

BIS M-105-01/A

BIS M-151-02/A
BIS M-101-01/L

BIS M-102-01/L

BIS M-120-01/L
with clear zone
Data carriers

dimensions

Read/write head A C A C A C A C A C
BIS M-300-001 100 30 150 30 100 20
BIS M-301-001 200 70 200 70 250 70
BIS M-302-001 60 30 60 30 60 30
BIS M-351-001 250 70
BIS M-304-001 60 30 60 30 60 30
BIS M-400-007-001 100 30 150 30 100 20
BIS M-400-007-002 60 30 60 30 60 30
BIS M-401-007-001 200 70 200 70 250 70
BIS M-451-007-001 250 70
Dimensions in mm

Basic
Information
and Definitions
General
information
Mechanical
properties
Quality
BIS U
BIS M
BIS C
BIS L
Mechanical strength Data carriers and read/write heads BIS M-1_ _, BIS M-3_ _ BIS S
Shock load 100 g/6 ms per EN 60068-2-27 and 100 g/2 ms per EN 60068-2-29 Interaction
Vibration 20 g, 10...2000 Hz per EN 60068-2-6 between
read/write
heads and
Processors BIS M-6_ _ _ data carriers
BVS
Shock load 15 g/11 ms per EN 60068-2-27 and 15 g/6 ms per EN 60068-2-29
Vibration 5 g, 10...150 Hz per EN 60068-2-6

■ www.balluff.com 361
Basic Information and Definitions
BIS M read/write times

Memory access Our processors can read or write each individual byte in the data
carrier. But since the data carrier is divided into 16-byte blocks, the
actual reading and writing is done by blocks. Our processor electro-
nics converts this time accordingly. To calculate the read/write times
the block read or write time must however be used.

Data carrier recognition 20 ms are required to recognize a data carrier.

Read times BIS M-1_ _ EEPROM – Data carrier with 16 byte blocks FRAM – Data carrier with 16 byte blocks
Byte read time Byte read time
from 0 to 15 20 ms from 0 to 15 30 ms
for each additional 10 ms for each additional 15 ms
16 bytes started add 16 bytes started add
an additional add an additional

Write times BIS M-1_ _ EEPROM – Data carrier with 16 byte blocks FRAM – Data carrier with 16 byte blocks
Byte write time Byte write time
from 0 to 15 40 ms from 0 to 15 60 ms
for each additional 30 ms for each additional 40 ms
16 bytes started add 16 bytes started add
an additional add an additional

Example:

Read and write 183 bytes starting at address 42


Address 42 is in Block 3 (42/16)
Address 224 is in Block 14 (224/16)

Therefore a total of 12 blocks will be processed, where the


first block always has a slightly longer read or write time.

Read time = 20 ms + 11 × 10 ms = 130 ms


Write time = 40 ms + 11 × 30 ms = 370 ms

Attention! Fluctuations in the ms range are possible.


Electrical noise effects may increase the read/write time.

362
Basic Information and Definitions
BIS M read/write times

Read/write cycles Data carriers Memory type Write cycles Read cycles Data retention time
112 bytes EEPROM 100000 unlimited 10 years
160 bytes EEPROM 100000 unlimited 10 years
736 bytes EEPROM 100000 unlimited 10 years
752 bytes EEPROM 100000 unlimited 10 years
992 bytes EEPROM 100000 unlimited 10 years
2000 bytes FRAM unlimited unlimited 10 years
8192 bytes FRAM unlimited unlimited 10 years

Maximum speed To calculate the permissible speed at which the data carrier and
head may move relative to one another, the static distance values
are used (see section BIS M).

The permissible speed is:

Path 2 × |offset value|


Vmax. perm. = =
Time Processing time

The offset value is dependent on the read/write distance actually


used in the system.

Read/write Read/write
Data-carrier
Processing time = + time of first block + n1 × time for other
detection time
to be read started blocks

n1 = Number of started blocks

Basic
Information
and Definitions
General
information
Mechanical
properties
Quality
BIS U
BIS M
BIS C
BIS L
BIS S
Interaction
between
read/write
heads and
data carriers
BVS

■ www.balluff.com 363
Basic Information and Definitions
BIS C installation notes

Mounting definitions Flush in steel


Active sensing surface can be flush mounted to surface of steel.
Consult part data sheet for additional information.
Non-flush on steel
Active sensing surface must be clear and not be surrounded by steel.
Consult part data sheet and clear zone definitions for more information.
Non-metal
Total clearance zone from any kind of metal must be maintained.
Consult part data sheet and clear zone definitions for more information.
Consult technical support for other metal mounting options.

Installation in steel For compliance to the read/write distances as rated for a given data
carrier to read/write head, the following Clear Zone Dimension must
be used for a "non-flush" or "non-metal" data carrier mounting:

Clear zone dimensions

Data carriers Fig. A D C B


BIS C-100-05/A 0 0 0 0
BIS C-103-_ _/A 0 0 0 0
BIS C-104-_ _/A 0 0 0 0
BIS C-105-_ _/A 0 0 0 0
BIS C-108-_ _/L 0 0 0 0 Fig. 1
BIS C-117-05/A 0 0 0 0
BIS C-117-05/L 5 60 20
BIS C-121-04/L 0 0 0 0
BIS C-122-_ _/L 0 0 0 0
BIS C-127-05/L 4 30 30 30
BIS C-128-_ _/L 5 60 20
BIS C-130-05/L 5 70 2
BIS C-133-_ _/L 0 0 0 0
BIS C-134-_ _/L 2 70 11
Fig. 2
BIS C-150-_ _/A 1 20 20 22
BIS C-190-_ _/L 3 20 17 20
BIS C-191-_ _/L 3 9 27 9

Read/write heads Fig. A B C


BIS C-300 0 0 0
BIS C-302 0 0 0
BIS C-305 0 0 0 Fig. 3
BIS C-306 0 0 0
BIS C-310 2 60 13
BIS C-315 0 0 0
BIS C-318 1 50 50 30
BIS C-319 2 50 35
BIS C-323 2 60 13
BIS C-324 1 0 0 0
BIS C-325 2 0 0 0 Fig. 4
BIS C-326 2 80 35
BIS C-327 1 50 50 20
BIS C-328 1 50 50 20
BIS C-350 1 60 50 60
BIS C-351 1 100 60 50
Dimensions in mm

Note! Depending on the combination of read/write head and data


carrier, clear zone dimension A and B should always be selected for Fig. 5
the larger of the components.

364
Basic Information and Definitions
BIS C installation notes

Installation in aluminum With clear zone, static operation


When installing components in aluminum, provide clear zones
for trouble-free operation. In static mode a clear zone depth in
aluminum of at least 10 mm must be maintained, Fig. 1. Clear zone
dimension A corresponds to the diameter of the larger communi-
cation partner (data carrier or read/write head) plus the maximum
possible offset (see specification for read/write head), Fig. 2. When
combined with read/write heads BIS C-318, 327, 328, 350, 351 and
355 dimension B and C are calculated from the length and width Fig. 1
of the larger communication partner (data carrier or read/write head)
plus the maximum permissible offset (see specification for read/write
head), Fig. 3.

Fig. 2

Fig. 3

Read/write path
With clear zone, dynamic operation
In dynamic mode a clear zone depth in aluminum of at least 10 mm
must be maintained, Fig. 1. Clear zone dimension A corresponds
to 2× the diameter of the larger communication partner + 1× the
diameter of the smaller communication partner. Clear zone dimen-
sion C corresponds to the diameter of the larger communication
partner plus the corresponding maximum offset (see specification
for read/write head), Fig. 4. When combined with read/write heads
BIS C-318, 327, 328, 350, 351 and 355 dimension B is calculated
from 2× the read/write path (see specification for read/write heads) Fig. 4
+ the width of the data carrier. Clear zone dimension C corresponds Read/write path
to the read/write head length plus the corresponding maximum
offset (see specification for read/write head), Fig. 5.

Basic
Information
and Definitions
General
information
Mechanical
properties
Fig. 5 Quality
BIS U
BIS M
BIS C
BIS L
BIS S
Interaction
between
read/write
heads and
data carriers
BVS

■ www.balluff.com 365
Basic Information and Definitions
BIS C installation notes

Installation in SK taper Data carrier BIS C-122 BIS C-103 BIS C-105
Taper DIN 69871-A DH11 t ±0.15 RPM max DH11 t ±0.15 RPM max DH11 t ±0.15 RPM max
Nr. 30 10 4.65 90000 12 8.15 68000 12 6.15 68000
Nr. 40 10 4.65 75000 12 8.15 54000 12 6.15 54000
Nr. 45 10 4.65 66000 12 8.15 43000 12 6.15 43000
Nr. 50 10 4.65 59000 12 8.15 33000 12 6.15 33000
Dimensions in mm

Sensing face
(Balluff logo)

R0.2
max.

Tool locating hole


(only if required)

"T" = 0 bis 0.2

Installation in retention knob Data carrier BIS C-122 BIS C-103 BIS C-105
Taper DIN 69871-A DH11 t ±0.15 DH11 t ±0.15 DH11 t ±0.15
Nr. 30
Nr. 40 10 4.65
Nr. 45 10 4.65 12 8.15 12 6.15
Nr. 50 10 4.65 12 8.15 12 6.15
Dimensions in mm

Stamp as
install help R 0.2 max.

Sensing face
(Balluff logo) std: DIN 69 872-A or
"T" = 0 to 0.2 DIN 69 872-B

Installation
1. Degrease gluing surfaces
2. Apply a bead of glue (recommended glue e.g. LOCTITE Hysol
1C or UHU-Plus endfest 300) approximately 3 mm wide around
the perimeter of the data carrier housing. Note manufacturer’s
instructions!
3. Press in data carrier housing by hand. Note dimension "T"!
4. Remove excess glue
5. Allow to harden

366
Basic Information and Definitions
BIS C installation notes

Installation in HSK taper Data carrier BIS C-122


HSK Form A ISO/DIN 12164-1 h3 +0.20 RPM max
32 5.4 96000
49 5.2 80000
50 5.1 75000
63 5 65000
80 4.9 57000
100 4.9 48000
Dimensions in mm

Mechanical strength Data carriers and read/write heads BIS C-1_ _, BIS C-3_ _
Shock load 100 g/6 ms per EN 60068-2-27 and 100 g/2 ms per EN 60068-2-29
Vibration 20 g, 10...2000 Hz per EN 60068-2-6
Values apply to data carriers BIS C-1_ _ and read/write heads
BIS C-3_ _ except for the non-potted read/write heads BIS C-350,
BIS C-351, BIS C-352 and BIS C-355.

Processors and non-potted read/write heads


BIS C-6_ _ _, BIS C-350, BIS C-351, BIS C-352, BIS C-355
Shock load 15 g/11 ms per EN 60068-2-27 and 15 g/6 ms per EN 60068-2-29
Vibration 5 g, 10...150 Hz per EN 60068-2-6

Basic
Information
and Definitions
General
information
Mechanical
properties
Quality
BIS U
BIS M
BIS C
BIS L
BIS S
Interaction
between
read/write
heads and
data carriers
BVS

■ www.balluff.com 367
Basic Information and Definitions
BIS C read/write times

Read/write cycles Data Memory Code Write cycles Write cycles Read cycles Memory
carriers type up to 30 °C up to 70 °C Organization
511 bytes EEPROM -04 1000000 500000 unlimited 32 byte blocks
1023 bytes EEPROM -05 1000000 500000 unlimited 32 byte blocks
2047 bytes EEPROM -11 1000000 500000 unlimited 64 byte blocks
8 Kbytes FRAM -32 unlimited unlimited unlimited 64 byte blocks

Read times in static mode For double read and compare:


Data carrier with 32-bytes blocks Data carrier with 64-bytes blocks
Bytes Read time Bytes Read time
from 0 up to 31 110 ms from 0 up to 63 220 ms
for each additional 120 ms for each additional 230 ms
32 bytes started add 64 bytes started add
an additional an additional
from 0 up to 255 = 950 ms from 0 up to 2047 = 7350 ms

Write times in static mode Includes checking and comparing:


Data carrier with 32-bytes blocks Data carrier with 64-bytes blocks
Bytes Write time [ms] Bytes Write time [ms]
from 0 up to 31 110 + n × 10 from 0 up to 63 220 + n × 10
≥ 32 y × 120 + n × 10 y × 230 + n × 10
from 0 up to 255 = max. 3510 from 0 up to 2047 = max. 27830
n = number of contiguous bytes to be programmed
y = number of blocks to be processed

Example:
Write 17 bytes starting at address 187. Data carrier block size = 32 bytes. Blocks 5 and 6
are processed, since the start address 187 is in block 5 and end address 204 is in block 6.

t = 2 × 120 + 17 × 10 = 410 ms

Read times in dynamic mode Read times within the 1st block for double read and compare:
Data carrier with 32-bytes blocks Data carrier with 64-bytes blocks
Bytes Read time Bytes Read time
from 0 up to 3 14 ms from 0 up to 3 14 ms
for each additional 3.5 ms for each additional 3.5 ms
bytes bytes
from 0 up to 31 112 ms from 0 up to 64 224 ms
The time indicated apply after the data carrier has been recognized. If the tag has not been recognized, an
additional 30 ms must be added to allow for creating the energy field necessary to recognize the Data carrier.

Example:
Read 11 bytes starting at address 9, i.e. the highest address to be read is 20 (use for “m” in the formula).

t = 14 ms + (m – 3) × 3.5 ms = 73.5 ms

In the internal memory organization of the data carrier, a distinction is made between the two block
sizes 32 and 64 bytes (also referred to as ‘page size’).

368
Basic Information and Definitions
BIS C read/write times

Memory organization Memory size up to 1023 bytes = 32 bytes per block


Memory size 2047 bytes and larger = 64 bytes per block

Maximum speed To calculate the permissible speed at which the data carrier and
head may move relative to one another, the static distance values
are used (see section BIS C).

The permissible speed is:

Path 2 × |offset value|


Vmax. perm. = =
Time Processing time

The offset value is dependent on the read/write distance actually


used in the system.

Read/write Read/write
Data-carrier
Processing time = + time of first block + n1 × time for other
detection time
to be read started blocks

n1 = Number of started blocks

Basic
Information
and Definitions
General
information
Mechanical
properties
Quality
BIS U
BIS M
BIS C
BIS L
BIS S
Interaction
between
read/write
heads and
data carriers
BVS

■ www.balluff.com 369
Basic Information and Definitions
BIS L installation notes

Mounting definitions Flush in steel


Active sensing surface can be flush mounted to surface of steel.
Consult part data sheet for additional information.
Non-flush on steel
Active sensing surface must be clear and not be surrounded by steel.
Consult part data sheet and clear zone definitions for more information.
Non-metal
Total clearance zone from any kind of metal must be maintained.
Consult part data sheet and clear zone definitions for more information.
Consult technical support for other metal mounting options.

Minimum distance between

BIS L-100-01/L

BIS L-101-01/L

BIS L-102-01/L

BIS L-103-05/L

BIS L-200-03/L

BIS L-201-03/L

BIS L-202-03/L

BIS L-203-03/L
two data carriers

BIS L-300 250 300 400 250 250 300 400 250
BIS L-301 300 400 500 350 350 400 500 350
BIS L-302 150 200 200 180 180 200 250 180
BIS L-303 300 400 500 350 350 400 500 350
BIS L-304 150 200 200 180 180 200 250 180
BIS L-40_ ≥ 250 ≥ 300 ≥ 400
Dimensions in mm

Minimum distance between BIS L-300 800 mm


two read/write heads BIS L-301 800 mm
BIS L-302 200 mm
BIS L-303 800 mm
BIS L-304 200 mm
Dimensions in mm

Distance from read head Read head Distance X Distance Y


to read head BIS L-40 _-...-001-... 1000 mm 1000 mm
BIS L-40 _-...-002-... 500 mm 300 mm
BIS L-40 _-...-003-... 500 mm 300 mm
BIS L-40 _-...-004-... 500 mm 300 mm
Dimensions in mm
Y

370
Basic Information and Definitions
BIS L installation notes

Mounting the read/write If the read/write heads are mounted so that they are joined through
heads on metal frames an enclosed metal frame, mutual interference may result (conductor
loop). This may reduce the read/write distances. The smaller the
read/write head, the less the interference. With the BIS L-301, the
maximum distance can be reduced by up to 20 %. The distance
should therefore be tested.

Read/write heads Metal frame

Installation in metal For compliance to the read/write distances as rated for a given data
carrier to read/write head, the following Clear Zone Dimension must
be used for a "non-flush" or "non-metal" data carrier mounting.

Clear zone dimensions

Data carriers Fig. A D C B


BIS L-100-01/L 1 100 50
BIS L-101-01/L 1 100 50
BIS L-102-01/L 1 100 50
BIS L-103-05/L 1 100 50
BIS L-150-05/A 3 0 3 0*
BIS L-200-03/L 1 100 50 Fig. 1

BIS L-201-03/L 1 100 50


BIS L-202-03/L 1 100 50
BIS L-203-03/L 1 100 50

Read/write heads Fig. A D C B


BIS L-300-_ _ 2 100 50
BIS L-301-_ _ 1 240 0
BIS L-302-_ _ 2 100 10
BIS L-303-_ _ 3 80 60 50
Fig. 2
BIS L-350-001-S4 50 50 30
BIS L-304-_ _ 3 50 50 10 Basic
BIS L-400-_ _-001 2 100 40 Information
and Definitions
BIS L-400-_ _-002 2 100 10
General
BIS L-400-_ _-003 2 100 10 information
BIS L-400-_ _-004 3 50 50 10 Mechanical
BIS L-405-_ _-001 2 100 40 properties
Quality
BIS L-405-_ _-002 2 100 10
BIS U
BIS L-405-_ _-003 2 100 10
BIS M
BIS L-405-_ _-004 3 50 50 10 Fig. 3
BIS C
*in steel and BIS L-350 head BIS L
BIS S
Dimensions in mm Interaction
between
read/write
Note! Depending on the combination of read/write head and data heads and
data carriers
carrier, clear zone dimension A should always be selected for the
BVS
larger of the components. If the clear zones cannot be maintained,
the read/write distance will be reduced.

■ www.balluff.com 371
Basic Information and Definitions
BIS L installation notes

Mechanical strength Data carriers and read/write heads BIS L-1_ _, BIS L-2_ _, BIS L-3_ _, BIS L-4_ _
Shock load 100 g/6 ms per EN 60068-2-27 and 100 g/2 ms per EN 60068-2-29
Vibration 20 g, 10...2000 Hz per EN 60068-2-6

Processors BIS L-6_ _ _


Shock load 15 g/11 ms per EN 60068-2-27 and 15 g/6 ms per EN 60068-2-29
Vibration 5 g, 10...150 Hz per EN 60068-2-6

Maximum speed To calculate the permissible speed at which the data carrier and
head may move relative to one another, the static distance values
are used (see section BIS L).

The permissible speed is:

Path 2 × |offset value|


Vmax. perm. = =
Time Processing time

The offset value is dependent on the read/write distance actually


used in the system.

Read/write Read/write
Data-carrier
Processing time = + time of first block + n1 × time for other
detection time
to be read started blocks

n1 = Number of started blocks

372
Basic Information and Definitions
BIS L read times

Read times BIS L-1_ _ Typically 110 ms for recognizing the serial number*

Data carrier with 4 byte blocks


Byte read time
from 0 to 3 180 ms
for each additional 90 ms
4 bytes started add
an additional

Read times BIS L-2_ _ Serial number recognition = read data carrier = 100 ms*

Write times BIS L-1_ _


Data carrier with 4 byte blocks
Byte write time
from 0 to 3 305 ms
or each additional 215 ms
4 bytes started add
an additional

*Applies only to parameter type and serial number output.

All specifications are typical values. Deviations are possible depending


on the application and combination of read/write head and data carrier.

Basic
Information
and Definitions
General
information
Mechanical
properties
Quality
BIS U
BIS M
BIS C
BIS L
BIS S
Interaction
between
read/write
heads and
data carriers
BVS

■ www.balluff.com 373
Basic Information and Definitions
BIS S installation notes

Mounting definitions Flush in steel


Active sensing surface can be flush mounted to surface of steel.
Consult part data sheet for additional information.
Non-flush on steel
Active sensing surface must be clear and not be surrounded by steel.
Consult part data sheet and clear zone definitions for more information.
Non-metal
Total clearance zone from any kind of metal must be maintained.
Consult part data sheet and clear zone definitions for more information.
Consult technical support for other metal mounting options.

Installation in steel For compliance to the read/write distances as rated for a given data
carrier to read/write head, the following Clear Zone Dimension must
be used for a "non-flush" data carrier mounting:

Clear zone dimensions

Data carriers Fig. A B C


BIS S-108-_ _/L 1 35 35 11
BIS S-150-_ _/A 1 20 20 22

Read/write heads Fig. A D B


BIS S-301 2 80 80 40
BIS S-302 3 10 10 40 Fig. 1
BIS S-303 4 10 10 40
Dimensions in mm

Installation in aluminum Clear zone dimensions

Data carriers Fig. A B C


BIS S-108-_ _/L 1 35 35 11 Fig. 2
BIS S-150-_ _/A 1 20 20 22

Read/write heads Fig. A D B


BIS S-301 2 80 80 40
BIS S-302 3 40 40 40
BIS S-303 4 40 40 40
Dimensions in mm Fig. 3

Note! Depending on the combination of read/write head and data


carrier, clear zone dimension A and B should always be selected for
the larger of the components.

Fig. 4

374
Basic Information and Definitions
BIS S installation notes and read/write times

Mechanical strength Data carriers and read/write heads BIS S-1_ _, BIS S-3_ _
Shock load 100 g/6 ms per EN 60068-2-27 and 100 g/2 ms per EN 60068-2-29
Vibration 20 g, 10...2000 Hz per EN 60068-2-6

Processors BIS S-6_ _ _


Shock load 15 g/11 ms per EN 60068-2-27 and 15 g/6 ms per EN 60068-2-29
Vibration 5 g, 10...150 Hz per EN 60068-2-6

Permissible inclination The sensing surfaces of read/write head and data carrier should
be installed in parallel. If the inclination of data carrier to read/write
head becomes over 10 degrees, read/write distance and offset
will decrease.
≤ 10°
BIS S-108

Read/write cycles Data Memory type Write cycles Write cycles Read cycles Memory
carriers organization
8 kBytes FRAM unlimited unlimited unlimited 64 byte blocks
16 kBytes FRAM unlimited unlimited unlimited 64 byte blocks
32 kBytes FRAM unlimited unlimited unlimited 128 byte blocks

Read times Byte read time


from 0 to 63 29 ms
for each additional 31 ms
64 bytes started add
an additional
from 0 to 2047 990 ms

Write times Byte write time [ms]


from 0 to 63 31 + n × 1.5
≥ 64 y × 31 + n × 1.5
from 0 to 2047 = max. 4064

n = Number of contiguous bytes to write


y = Number of blocks to process
Basic
Example: Information
and Definitions
Write 87 bytes starting with Address 187. Data carrier = 64-byte blocks. General
Blocks 2 to 5 are processed, since start address 187 is in Block 2 and information
end address 274 is in Block 5. Mechanical
properties
Quality
t = 4 × 31 + 87 × 1.5 = 255 ms BIS U
BIS M
BIS C
BIS L
Maximum speed No dynamic operation is recommendet. BIS S
Interaction
between
read/write
heads and
data carriers
BVS

■ www.balluff.com 375
Basic Information and Definitions
Interaction between read/write heads and data carriers

Spatial arrangement of The key to reliable data exchange between the read/write head resp.
read/write head resp. read read head and the data carrier is maintaining sufficient dwell time of
head and data carrier the data carrier within a specified spatial distance from the read/write
head resp. read head.
The sketches on the two following pages are intended to clarify this
requirement, in the first sketch for read/write heads resp. read heads
with non-directional operation, in the second for read/write heads
resp. read heads in cases where the data carrier have to pass by
from a certain direction or at a certain orientation.
For a static read/write resp. read operation the data carrier
stops completely in front of the read/write resp. read heads; this
permits a greater distance between the two.

Usable space for reading


from and writing to the
Permissible
data carrier
offset
Data carrier

Read/write head resp. read head

Spatial arrangement of read/write head resp. read head and data


carrier for non-directional read/write heads resp. read heads and
flush mounting (circular antenna).

376
Basic Information and Definitions
Interaction between read/write heads and data carriers

For dynamic operation the data carrier is read or programmed


on the fly. The shorter distance is necessary in order to achieve as
large a read/write resp. read path as possible.
Each read/write head or read head has certain data carrier which
can be used with it (the pairing is based on physical size and anten-
na field configuration).
The associated specifications for distance and permissible offset
are indicated as well as the distance and relative speed between
the read/write head or read head and the data carrier.

Usable space for reading


from and writing to the
Permissible data carrier
offset
Data carriers

Clear zone Read/write head resp. read head

Clear zone

Read/write direction
resp. read direction

Spatial arrangement of read/write head resp. read head and


data carrier for directional read/write heads resp. read heads and Basic
non-flush mount (bar-shaped antenna). Information
and Definitions
General
information
Mechanical
properties
Quality
BIS U
BIS M
BIS C
BIS L
BIS S
Interaction
between
read/write
heads and
data carriers
BVS

■ www.balluff.com 377
Basic Information and Definitions
BVS Vision Sensors

Sensor overview Teach and recovery button

Indicator LEDs

Internal lighting

Lens

Focus ring

Power connection (M12 connector, 8-pin)

Ethernet connection (M12 connector, 4-pin)

Current image ... is the image captured by the sensor, which is then processed.

Reference image Saved reference image. The pattern/contour/corner points in the


region of interest within the reference image define the pattern (or
contour) detected by the "Detect pattern", "Detect 360 degree
pattern" and "Detect contour" tool. The reference image does not
have a direct influence on any other tools, it is used as a reference
for detecting OK or NOK parts.

Region of interest (ROI) ... is the area within an image marked by a frame and inspected by a
tool. In the case of the tools "Detect pattern" and "Detect 360° pat-
tern", the ROI is the pattern that the sensor is searching for whereas
the image area being inspected is the search area.

Inspection An inspection consists of:


■ a taught-in reference image
■ the tools that inspect one or more regions of interest
within the digital image on the object
■ and the three functions assigned to digital outputs
e.g. output 1 signals the result "Inspection OK"
and output 2 signals "Inspection not OK".

All settings such as trigger, lighting etc. are saved during an


inspection.

Inspection result Possible results include: "Inspection OK" if the inspection returns
a positive result for all tools. "Inspection not OK" if at least one tool
returns a negative result or one or more tools are not taken into
account. Outputs can be assigned directly to single inspections.

Locator A locator tool can be used to compensate for a part that frequently
changes position. However, the part must not leave the field of view.
The locator tool follows the position of the part within the field of view
and aligns all other tools according to the current position of the part.

378
Basic Information and Definitions
BVS Vision Sensors

Inspection times The total inspection time consists of the exposure time, capture time
and processing time.

Exposure time: the exposure time is referred to as the "shutter


speed". The amount of light that shines on the image sensor is
directly proportional to the exposure time and the light currently
available. The longer the exposure time, the greater the amount
of light that shines on the image sensor. When configuring the
correct exposure time, the following factors are most important:
■ Speed of the part scheduled for inspection
■ Number of parts per second
■ Continuously available light

Capture time: The time required to capture an image. After exposure


of the image sensor, the image must be transferred to the memory
on the device. The whole process takes approximately 30 ms for a
complete image. The time decreases considerably if only part of the
complete image is captured.

Processing time: The time taken to process the captured image.


Depends on the operations and tools used for the inspection.

Working distance The working distance describes the minimum and maximum
and field of view distance between the sensor lens and object. The field of view is
the surface area that the sensor can detect at the specified working
distance. The larger the working distance, the larger the field of view.
The light intensity of the illuminated object decreases by the square
root of the working distance. Objects positioned further away appear
darker than closer objects as a result.

50 mm 150 mm 500 mm 1000 mm

6 mm Wide-angle lens 34×25 mm 101x76mm 338x253mm 676×507 mm


8 mm Standard lens 24×18 mm 72x54mm 240x180mm 480×360 mm
12 mm Telephoto lens 16×12 mm 48x36mm 160x120mm 320×240 mm

* Working range 180 to 1000 mm

Basic
Bring your working range up close with the telephoto lens. Or take Information
and Definitions
advantage of the larger field of view at the same working distance General
offered by the wide-angle and standard lenses. Use the distance information
computer: www.balluff.de/vision Mechanical
properties
Quality
BIS U
BIS M
BIS C
BIS L
BIS S
Interaction
between
read/write
heads and
data carriers
BVS

■ www.balluff.com 379
Basic Information and Definitions
BVS Vision Sensors

IP address The IP address is a unique address that identifies a network


device and allows you to communicate with the sensor.
The standard address of all BVS devices is: 172.27.101.208

Supply voltage UB ... is the voltage range in which flawless functioning of the sensor is
assured. It includes all voltage tolerances and ripple.

Rated operating current Ie On BVS Vision Sensors:


... is the maximum current with which the sensor may be loaded at
its output in continuous operation.

On BAE lights:
... is the current required for operation.

Typ. detection rate Different calculating times are required to evaluate the tools in an
inspection. The typical detection rate is a guide value that indicates
how often a part can be inspected per second.

Ambient temperature The ambient temperature determines the temperature range in


range Ta which the sensor may be operated.

Short-circuit protection and All DC sensors feature this protection device. In the event of overload
overload protection or short-circuit at the output, the output transistor is automatically
switched off. As soon as the malfunction has been corrected, the
output stage is reset to normal functioning.

Trigger The trigger signal starts an event. A trigger signal initiates the capture
and evaluation of an image in conjunction with the BVS. The BVS
has different trigger settings that can be configured using software
available free of charge.

Eye safety per EN 62471:2008 Any LED lights are categorized into different groups based on the
degree of risk to human eyes and skin. All Balluff lights are in the
lowest two groups.

Extempt group Risk group 1


Sensors or lights do not pose Sensors or lights do not pose a risk
a photobiological risk due to standard precautionary measures
taken by the user
■ Vision Sensors BVS-E ■ Background lights, infrared
■ Background lights, red light ■ Ring lights, infrared
■ Ring lights, red and white light ■ Line lights, infrared during boost mode
■ Line lights, red and white light ■ Spotlights, infrared
■ Line lights, infrared during normal operation
■ Spotlights, red light
■ Dark field illumination, red light
■ Coaxial lights, red light

380
Basic Information and Definitions
BVS Vision Sensors

Software You will require the ConVis software to operate Balluff Vision
Sensors, which is available free of charge. The product is supplied
with a CD ROM containing the software.

ConVis software Step 1 Step 2 Step 3


Connect Configure Run
Establish a connection between Determine the features you wish Test the inspection –
the ConVis software and the to inspect and select all the rele- view the results and correct
sensor. Determine the image vant tools. Configure the output if necessary.
brightness and lighting settings. signals.

BVS-E with Balluff BVS ConVis – the "Easy to Use" software


Connect the BVS-E Vision Sensor to your PC over Ethernet.
The built-in software wizard guides you to successful configuration
in just three steps. Simply enter your desired inspection parts or
features, test your inspection, and check the results on the screen.
Slight changes and corrections are easily made. Clear guidance
eliminates the need to learn a programming language or undergo
expensive training.

PLC

Monitor Step 1 Step 2 Step 3


Connect Monitor Adjust
Connect the sensor Visualizes the sensor images Set the tool parameters
to the monitor. and inspection results and and test your inspection.
displays process statistics.

Especially easy to set up using the monitor Basic


If you want to increase the statistical quality of your checks or easily Information
and Definitions
modify your checks in line with part changes, you should be able to General
see what the sensor sees. With the vision sensor monitor, this is no information
problem. Making corrections in-process is easy, because the display Mechanical
properties
provides continuous status monitoring in-place. So you are continu-
Quality
ally checking the sensor function and you can immediately correct BIS U
deviations. Product defects are detected directly. BIS M
BIS C
BIS L
BIS S
Interaction
between
read/write
heads and
data carriers
PLC
BVS

■ www.balluff.com 381
Alphanumeric Directory
Sorted by part number

Part number Ordering Page Part number Ordering Page


code code
BAM MB-XA-003-B03-1 BAM01AC 327 BCC A325-0000-10-063-PX05A5-100 BCC06HK 306
BAM MB-XA-010-B07-4 BAM01MY 320 BCC A325-A315-30-335-PX05A5-006 BCC06H1 307
Sorted by BAM MB-XA-012-B09-4 BAM01UH 320 BCC A325-A315-30-335-PX05A5-020 BCC06H2 307
BAM MC-XA-016-Q40-1 BAM01TM 318 BCC A325-A315-30-335-PX05A5-050 BCC06H3 307
part number BAM MC-XA-018-B04-4 BAM01Y3 320 BCC A325-A315-30-335-PX05A5-100 BCC06H4 307
BAM MC-XA-021-M18-2 BAM01W4 323 BCC A325-A315-30-335-PX05A5-150 BCC06H5 307
Part number Ordering Page BAM MC-XA-021-M18-4 BAM01WJ 323 BCC A325-A325-30-335-PX05A5-006 BCC06H6 307
code BAM MC-XA-021-M18-A BAM01WL 323 BCC A325-A325-30-335-PX05A5-020 BCC06H7 307
BAM MC-XA-021-M30-2 BAM01W5 323 BCC A325-A325-30-335-PX05A5-050 BCC06H8 307
BAE BAM MC-XA-021-M30-4 BAM01WK 323 BCC A325-A325-30-335-PX05A5-100 BCC06H9 307
BAE LX-VS-DR090 BAE00AM 346 BAM MC-XA-021-M30-A BAM01WM 323 BCC A325-A325-30-335-PX05A5-150 BCC06HA 307
BAE LX-VS-HI050 BAE00KR 335 BAM OF-VS-001-D-RX100 BAM01A7 338 BCC A335-0000-10-000-61X5A5-000 BCC070F 294
BAE LX-VS-HI100 BAE00FR 335 BAM PC-AE-002-1 BAM01A8 330 BCC A335-0000-20-000-61X5A5-000 BCC070K 294
BAE LX-VS-HI150 BAE00KP 336 BAM PC-AM-010-4 BAM01Y8 320 BCC A415-0000-1A-030-VS85N6-020 BCC0CZW 297,
BAE LX-VS-HI200 BAE00JE 337 BAM PC-VS-008-1 BAM01RR 331 302
BAE LX-VS-HR025 BAE000E 334 BCC A415-0000-1A-030-VS85N6-050 BCC0CZY 297,
BAE LX-VS-HR050 BAE000F 334 BAV 302
BAE LX-VS-HR100 BAE000H 335 BAV BP-PH-00017-01 SET012J 269 BCC A415-0000-1A-030-VS85N6-100 BCC0CZZ 297,
BAE LX-VS-HR100-E BAE00JF 337 BAV BP-PH-00018-01 SET012K 269 302
BAE LX-VS-HR150 BAE00C5 336 BAV BP-PH-00019-01 SET012L 269 BCC A415-0000-2A-030-VS85N6-020 BCC0E00 297,
BAE LX-VS-HR200 BAE00JC 337 BAV BP-PH-00020-01 SET012M 269 303
BAE LX-VS-LI085 BAE00AT 341 BAV BP-PH-00021-01 SET012N 269 BCC A415-0000-2A-030-VS85N6-050 BCC0E01 297,
BAE LX-VS-LI170 BAE00AY 341 BAV BP-PH-00022-01 SET012P 269 303
BAE LX-VS-LR085 BAE00AP 340 BAV BP-PH-00023-01 SET012R 269 BCC A415-0000-2A-030-VS85N6-050 BCC0E01 303
BAE LX-VS-LR170 BAE00AZ 340 BAV BP-PH-00024-01 SET012T 269 BCC A415-0000-2A-030-VS85N6-100 BCC0E02 297
BAE LX-VS-LW085 BAE00AR 341 BAV BP-PH-00025-01 SET012U 269 BCC A415-0000-2A-030-VS85N6-100 BCC0E02 303
BAE LX-VS-LW170 BAE00AW 341 BAV BP-PH-00026-01 SET012W 269 BCC A415-A415-3A-330-VS85N6-006 BCC0E03 297
BAE LX-VS-OR100 BAE00JA 345 BAV BP-PH-00068-01 SET0121 269 BCC A415-A415-3A-330-VS85N6-020 BCC0E04 297
BAE LX-VS-OR50 BAE00J9 345 BAV BP-PH-00069-01 SET0122 269 BCC A415-A415-3A-330-VS85N6-050 BCC0E05 297
BAE LX-VS-RI100 BAE000K 339 BAV BP-PH-00070-01 SET0123 269 BCC A415-A415-3A-330-VS85N6-100 BCC0E06 297
BAE LX-VS-RI100-S BAE00FN 339 BAV BP-PH-00071-01 SET0124 269 BCC A415-A415-3A-330-VS85N6-150 BCC0E07 297
BAE LX-VS-RR100 BAE000J 338 BAV BP-PH-00073-01 SET0125 269 BCC E878-0000-Z1-41X8T4 BCC09N2 315
BAE LX-VS-RR100-S BAE00FP 338 BAV BP-PH-00074-01 SET0126 269 BCC M313-0000-10-001-PX0334-020 BCC02M8 309
BAE LX-VS-RW100 BAE00AN 339 BAV BP-PH-00075-01 SET0127 269 BCC M313-0000-10-001-PX0334-050 BCC02M9 309
BAE LX-VS-RW100-S BAE00FM 339 BAV BP-PH-00076-01 SET0128 269 BCC M313-0000-10-001-PX0334-100 BCC02MA 309
BAE LX-VS-SI018 BAE00H1 343 BAV BP-PH-00077-01 SET0129 269 BCC M313-0000-10-001-VX8334-020 BCC02NU 309
BAE LX-VS-SI030 BAE00H2 343 BAV BP-PH-00078-01 SET012A 269 BCC M313-0000-10-001-VX8334-050 BCC02NW 309
BAE LX-VS-SR012 BAE00KF 342 BAV BP-PH-00079-01 SET012C 269 BCC M313-0000-10-001-VX8334-100 BCC02NY 309
BAE LX-VS-SR018 BAE00H0 343 BAV BP-PH-00092-01 SET014R 269 BCC M414-0000-2A-068-VS24N7-020 BCC084R 298
BAE LX-VS-SR030 BAE00FT 343 BAV BP-PH-00092-02 SET014T 269 BCC M414-0000-2A-068-VS24N7-050 BCC084T 298
BAE LX-XO-PL018-L1-S4 BAE00KE 347 BAV BP-PH-00092-03 SET014U 269 BCC M414-0000-2A-068-VS24N7-100 BCC084U 298
BAE LX-XO-PL018-L2-S4 BAE00KZ 347 BAV BP-PH-00092-04 SET014W 269 BCC M414-E834-8G-668-PS54T2-006 BCC04K6
BAE PD-VS-002-E BAE00EH 268 BAV BP-PH-00092-05 SET014Y 269 BCC M414-E834-8G-668-PS54T2-020 BCC04K7 293
BAE PS-XA-1W-24-038-601 BAE00EN 351 BAV BP-PH-00092-06 SET014Z 269 BCC M414-E834-8G-668-PS54T2-050 BCC04K8 293
BAE PS-XA-1W-24-038-602 BAE00EP 351 BAV BP-PH-00092-07 SET0150 269 BCC M414-E834-8G-668-PS54T2-100 BCC04K9 293
BAE PS-XA-1W-24-038-603 BAE00ER 351 BCC M414-E834-8G-668-PS54T2-150 BCC04ZJ 293
BAE PS-XA-1W-24-038-607 BAE00FW 351 BCC BCC M414-E834-8G-668-PS54T2-200 BCC04KA 293
BAE PS-XA-1W-24-050-013 BAE00EK 351 BCC 0000-0000-00-000-PS72N1-10X BCC0ACA 291 BCC M414-E834-8G-668-PS54T2-300 BCC04KC 293
BAE PS-XA-1W-24-080-604 BAE00ET 351 BCC A315-0000-10-030-VS85N6-020 BCC09UY 302 BCC M415-0000-1A-003-PX0434-020 BCC032F 305,
BAE PS-XA-1W-24-080-605 BAE00FL 351 BCC A315-0000-10-030-VS85N6-050 BCC09W0 302 309
BAE PS-XA-1W-24-080-606 BAE00FY 351 BCC A315-0000-10-030-VS85N6-100 BCC09W3 302 BCC M415-0000-1A-003-PX0434-050 BCC032H 305,
BAE PS-XA-1W-24-100-014 BAE00EU 351 BCC A315-0000-10-063-PX05A5-020 BCC06HC 306 309
BAE-PS-XA-1W-12-015-001 BAE0036 349 BCC A315-0000-10-063-PX05A5-050 BCC06HE 306 BCC M415-0000-1A-003-PX0434-100 BCC032J 305,
BAE-PS-XA-1W-12-025-002 BAE0039 349 BCC A315-0000-10-063-PX05A5-100 BCC06HF 306 309
BAE-PS-XA-1W-12-050-002 BAE003E 349 BCC A315-0000-1A-R04 BCC0A0A 295 BCC M415-0000-1A-003-VX8434-020 BCC0367 309
BAE-PS-XA-1W-12-100-003 BAE003H 349 BCC A315-0000-2A-R04 BCC0A09 304 BCC M415-0000-1A-003-VX8434-050 BCC0368 309
BAE-PS-XA-1W-24-007-001 BAE0001 349 BCC A315-A315-30-330-VS85N6-006 BCC09YA 302 BCC M415-0000-1A-003-VX8434-100 BCC0369 309
BAE-PS-XA-1W-24-012-002 BAE0004 349 BCC A315-A315-30-330-VS85N6-020 BCC09YE 302 BCC M415-0000-1A-014-PS0434-020 BCC032K 278
BAE-PS-XA-1W-24-025-002 BAE0005 349 BCC A315-A315-30-330-VS85N6-050 BCC09YJ 302 BCC M415-0000-1A-014-PS0434-050 BCC032L 278
BAE-PS-XA-1W-24-038-003 BAE003J 349 BCC A315-A315-30-330-VS85N6-100 BCC09YP 302 BCC M415-0000-1A-014-PS0434-100 BCC032M 278
BAE-PS-XA-1W-24-050-003 BAE0006 349 BCC A315-A315-30-330-VS85N6-150 BCC09YT 302 BCC M415-0000-1A-014-VS8434-020 BCC036A 278
BAE-PS-XA-1W-24-100-004 BAE0002 349 BCC A315-A315-30-335-PX05A5-006 BCC06FM 307 BCC M415-0000-1A-014-VS8434-050 BCC036C 278
BAE-PS-XA-1W-24-200-005 BAE0003 349 BCC A315-A315-30-335-PX05A5-020 BCC06FN 307 BCC M415-0000-1A-014-VS8434-100 BCC036E 278
BAE-PS-XA-1W-48-025-003 BAE003K 349 BCC A315-A315-30-335-PX05A5-050 BCC06FP 307 BCC M415-0000-1A-068-VS24N7-020 BCC06Y1 298
BAE-PS-XA-1W-48-050-004 BAE003L 349 BCC A315-A315-30-335-PX05A5-100 BCC06FR 307 BCC M415-0000-1A-068-VS24N7-050 BCC06Y2 298
BAE-PS-XA-1W-48-100-005 BAE003M 349 BCC A315-A315-30-335-PX05A5-150 BCC06FT 307 BCC M415-0000-1A-068-VS24N7-100 BCC06Y3 298
BAE-PS-XA-3Y-24-050-009 BAE0007 349 BCC A315-A315-A315-T0023-000 BCC0AA7 295 BCC M415-0000-1A-R04 BCC0A08 296
BAE-PS-XA-3Y-24-100-006 BAE0008 349 BCC A315-A325-30-335-PX05A5-006 BCC06FU 307 BCC M415-0000-1B-R01 BCC0C6E 291
BAE-PS-XA-3Y-24-200-007 BAE0009 349 BCC A315-A325-30-335-PX05A5-020 BCC06FW 307 BCC M415-0000-2A-R04 BCC09MR 304
BAE-PS-XA-3Y-24-400-010 BAE003R 349 BCC A315-A325-30-335-PX05A5-050 BCC06FY 307 BCC M415-0000-2B-R01 BCC0718 291
BCC A315-A325-30-335-PX05A5-100 BCC06FZ 307 BCC M415-E834-AG-672-ES64N8-050 BCC0E7T 308
BAM BCC A315-A325-30-335-PX05A5-150 BCC06H0 307 BCC M415-E834-AG-672-ES64N8-150 BCC0E7W 308
BAM FK-VS-002-03-1 BAM0206 330 BCC A325-0000-10-063-PX05A5-020 BCC06HH 306 BCC M415-M412-3B-329-PS72N1-003 BCC0A11 291
BAM MB-XA-002-B02-1 BAM01AE 327 BCC A325-0000-10-063-PX05A5-050 BCC06HJ 306 BCC M415-M412-3B-329-PS72N1-006 BCC0A12 291

382
Alphanumeric Directory
Sorted by part number

Part number Ordering Page Part number Ordering Page Part number Ordering Page
code code code
BCC M415-M412-3B-329-PS72N1-010 BCC0A13 291 BCC M474-0000-2A-000-01X475-000 BCC0869 279 BIS C-300-PU1-10 BIS00P6 140
BCC M415-M412-3B-329-PS72N1-020 BCC0A14 291 BCC M474-0000-2D-000-51X475-000 BCC03WZ 292 BIS C-300-ZA1 BAM012C 183
BCC M415-M412-3B-329-PS72N1-050 BCC0A15 291 BCC M475-0000-1A-000-01X575-000 BCC06ZN 305 BIS C-302-PU1-05 BIS00PA 141
BCC M415-M414-3A-304-PX0434-003 BCC039H 274 BCC M475-0000-1B-000-01X575-000 BCC0715 290 BIS C-302-PU1-10 BIS00P9 141
BCC M415-M414-3A-304-PX0434-006 BCC039J 274 BCC M475-0000-2B-000-01X575-000 BCC0714 290 BIS C-305-PU1-01 BIS0066 142
BCC M415-M414-3A-304-PX0434-010 BCC039K 274 BCC M484-0000-1D-000-51X475-000 BCC03Y2 293 BIS C-305-PU1-05 BIS0067 142
BCC M415-M414-3A-304-PX0434-015 BCC039L 274 BCC M484-0000-2D-000-51X475-000 BCC03Y0 293 BIS C-305-PU1-10 BIS0068 142
BCC M415-M414-3A-304-PX0434-020 BCC039M 274 BCC M485-0000-1B-000-01X575-000 BCC0717 290 BIS C-306-PU1-01 BIS00PC 140
BCC M415-M414-3A-304-PX0434-030 BCC039N 274 BCC M485-0000-2B-000-01X575-000 BCC0716 290 BIS C-306-PU1-05 BIS006F 140
BCC M415-M414-3A-304-PX0434-050 BCC039P 274 BIS C-306-PU1-10 BIS00PE 140
BCC M415-M414-3A-305-PS0434-030 BCC0C8L 276 BDN BIS C-310-PU1-01 BIS00PF 145
BCC M415-M414-3A-305-PS0434-050 BCC0C02 276 BDN T-DTE-AD-01 BCC07WZ 304 BIS C-310-PU1-05 BIS00PH 145
BCC M415-M414-3A-305-PS0434-100 BCC0C03 276 BDN T-DTN-DD-01 BCC07WR 296 BIS C-310-PU1-10 BIS00PJ 145
BCC M415-M414-3A-305-PS0434-200 BCC0C04 276 BIS C-315/05-S4 BIS006Y 148
BCC M415-M414-3A-337-VS24N7-006 BCC06WU 298 BES BIS C-315/10-S4 BIS006Z 148
BCC M415-M414-3A-337-VS24N7-020 BCC06WW 298 BES 14,5-BS-1 BAM00EM 322 BIS C-315-PU1-01 BIS00PK 144
BCC M415-M414-3A-337-VS24N7-050 BCC06WY 298 BES 16,0-BS-1 BAM00ET 322 BIS C-315-PU1-05 BIS00PL 144
BCC M415-M414-3A-337-VS24N7-100 BCC06WZ 298 BES 18,0-BS-1 BAM00F2 322 BIS C-315-PU1-10 BIS00PM 144
BCC M415-M414-3A-337-VS24N7-150 BCC06Y0 298 BES 18,0-HW-1 BAM00EY 321 BIS C-318-PU1-05 BIS0075 151
BCC M415-M415-5D-687-ES64N8-020 BCC0ANA 309 BES 18,0-KB-3 BAM00F7 321 BIS C-318-PU1-10 BIS00L4 151
BCC M415-M415-5D-687-ES64N8-050 BCC0ANC 309 BES 18,0-KB-3-F-SA1 BAM00F9 321 BIS C-319/01-S4 146
BCC M415-M424-3A-304-PX0434-003 BCC039R 275 BES 18.0-KH-2S BAM00FT 322 BIS C-319/05-S4 BIS007A 146
BCC M415-M424-3A-304-PX0434-006 BCC039T 275 BES 30,0-BS-1 BAM00HN 322 BIS C-319/10-S4 BIS007C 146
BCC M415-M424-3A-304-PX0434-010 BCC039U 275 BES 30,0-HW-1 BAM00HH 321 BIS C-319-PU1-01 BIS0077 143
BCC M415-M424-3A-304-PX0434-015 BCC039W 275 BES 30,0-KB-3-F BAM00HU 321 BIS C-319-PU1-05 BIS0078 143
BCC M415-M424-3A-304-PX0434-020 BCC039Y 275 BES 30,0-KH-2L BAM00J4 322 BIS C-319-PU1-10 BIS0079 143
BCC M415-M424-3A-304-PX0434-030 BCC039Z 275 BES 30,0-KH-2S BAM00J6 322 BIS C-323/01-S4 BIS007J 147
BCC M415-M424-3A-304-PX0434-050 BCC03A0 275 BES HS-01-P1-C16/Q40 BAM00JT 319 BIS C-323/05-S4 BIS007K 147
BCC M415-M424-3A-305-PS0434-030 BCC0E3J 276 BES HS-01-P1-C8/Q40 BAM00JU 319 BIS C-323/10-S4 BIS007L 147
BCC M415-M424-3A-305-PS0434-050 BCC0E3K 276 BES Q40-HW-1 BAM00JW 318 BIS C-324/05-S4 BIS007M 149
BCC M415-M424-3A-305-PS0434-100 BCC0E3L 276 BIS C-324/10-S4 BIS007N 149
BCC M415-M424-3A-305-PS0434-200 BCC0E3M 276 BIS BIS C-325/01-S4 BIS007P 146
BCC M415-U024-8F-696-VX04T8-018 BCC0CR2 279 BIS C-100-05/A BIS0002 135 BIS C-325/05-S4 BIS007R 146
BCC M418-0000-1A-046-PS0825-020 BCC0994 308 BIS C-103-05/A BIS0004 134 BIS C-325/10-S4 BIS007T 146
BCC M418-0000-1A-046-PS0825-050 BCC0995 308 BIS C-104-11/A BIS0006 136 BIS C-326-PU1-05 BIS007Y 143
BCC M418-0000-1A-046-PS0825-100 BCC0996 308 BIS C-104-32/A BIS0007 136 BIS C-326-PU1-10 BIS007Z 143
BCC M418-0000-1A-046-PS0825-200 BCC09HL 308 BIS C-105-05/A BIS0009 134 BIS C-327-01 150
BCC M418-0000-1A-046-PS0825-400 BCC0AT8 308 BIS C-108-05/L BIS000C 136 BIS C-327-05 BIS0080 150
BCC M425-0000-1A-014-PS0434-020 BCC0331 278 BIS C-108-05/L-SA2 BIS000F 139 BIS C-327-10 150
BCC M425-0000-1A-014-PS0434-050 BCC0332 278 BIS C-108-11/L BIS000H 136 BIS C-328/01-S49 151
BCC M425-0000-1A-014-PS0434-100 BCC0333 278 BIS C-108-11/L-SA2 BIS000J 139 BIS C-328/05-S49 BIS0081 151
BCC M425-0000-1A-014-VS8434-020 BCC036T 278 BIS C-108-32/L BIS000K 136 BIS C-328/10-S49 151
BCC M425-0000-1A-014-VS8434-050 BCC036U 278 BIS C-117-05/A BIS000M 135 BIS C-350-00.3 BIS0086 153
BCC M425-0000-1A-014-VS8434-100 BCC036W 278 BIS C-117-05/L BIS000N 135 BIS C-351-PU1-05 BIS00PN 151
BCC M425-M414-3A-304-PX0434-003 BCC03A8 274 BIS C-117-11/L BIS000R 135 BIS C-351-PU1-10 BIS00PP 151
BCC M425-M414-3A-304-PX0434-006 BCC03A9 274 BIS C-121-04/L BIS000T 134 BIS C-355/05-S92 BIS008E 153
BCC M425-M414-3A-304-PX0434-010 BCC03AA 274 BIS C-121-04/L-SA1 BIS000W 138 BIS C-380-05/06-02 BIS00JE 155
BCC M425-M414-3A-304-PX0434-015 BCC03AC 274 BIS C-122-04/L BIS0011 134 BIS C-380-05/06-05 BIS00N8 155
BCC M425-M414-3A-304-PX0434-020 BCC03AE 274 BIS C-122-04/L-ZC1 BIS002Y 183 BIS C-380-06/06-01 BIS00JJ 154
BCC M425-M414-3A-304-PX0434-030 BCC03AF 274 BIS C-122-11/L BIS0015 134 BIS C-380-06/06-02 BIS00LU 154
BCC M425-M414-3A-304-PX0434-050 BCC03AH 274 BIS C-127-05/L BIS0017 137 BIS C-380-06/06-05 BIS00N9 154
BCC M425-M414-3A-305-PS0434-030 BCC0E3C 277 BIS C-128-05/L BIS0019 135 BIS C-380-06/10-02 BIS00JM 155
BCC M425-M414-3A-305-PS0434-050 BCC0E3E 277 BIS C-128-11/L BIS001C 135 BIS C-380-06/10-05 BIS00JN 155
BCC M425-M414-3A-305-PS0434-100 BCC0E3F 277 BIS C-130-05/L BIS001E 135 BIS C-380-10/10-01 BIS00JP 155
BCC M425-M414-3A-305-PS0434-200 BCC0E3H 277 BIS C-130-05/L-SA1 BIS001H 138 BIS C-380-10/10-05 BIS00JR 155
BCC M425-M424-3A-304-PX0434-003 BCC03AJ 275 BIS C-133-05/L BIS001Z 139 BIS C-505-PU-01 BCC00N1 283
BCC M425-M424-3A-304-PX0434-006 BCC03AK 275 BIS C-133-11/L 139 BIS C-505-PU-05 BCC00N2 283
BCC M425-M424-3A-304-PX0434-010 BCC03AL 275 BIS C-134-05/L-H120 BIS0020 139 BIS C-505-PU-10 BCC00N3 283
BCC M425-M424-3A-304-PX0434-015 BCC03AM 275 BIS C-134-11/L BIS0021 139 BIS C-505-PU1-05 BCC00N4 283
BCC M425-M424-3A-304-PX0434-020 BCC03AN 275 BIS C-140-05/L-M6 BIS00J4 139 BIS C-505-PU1-10 BCC00N5 283
BCC M425-M424-3A-304-PX0434-030 BCC03AP 275 BIS C-140-05/L-M8 BIS00J2 139 BIS C-506-PU-01 BCC00N6 283
BCC M425-M424-3A-304-PX0434-050 BCC03AR 275 BIS C-140-11/L-M6 BIS00J3 139 BIS C-506-PU-05 BCC00N7 283
BCC M425-M424-3A-305-PS0434-030 BCC0E3N 277 BIS C-140-11/L-M8 BIS00J1 139 BIS C-506-PU-10 BCC00N8 283
BCC M425-M424-3A-305-PS0434-050 BCC0E3P 277 BIS C-150-05/A BIS0028 137 BIS C-506-PU1-05 BCC00N9 283
BCC M425-M424-3A-305-PS0434-100 BCC0E3R 277 BIS C-150-11/A BIS002A 137 BIS C-506-PU1-10 BCC00NA 283
BCC M425-M424-3A-305-PS0434-200 BCC0E3T 277 BIS C-150-32/A BIS002E 137 BIS C-516-PU-05 BCC00P4 287
BCC M434-0000-2A-000-51X475-000 BCC06F7 299 BIS C-190-05/L BIS002K 137 BIS C-516-PU-10 BCC00P5 287
BCC M434-0000-2A-000-55X450-000 BCC06Y5 299 BIS C-190-11/L BIS002M 137 BIS C-516-PU-20 BCC00P6 287
BCC M435-0000-1A-000-41X475-000 BCC06Z9 305 BIS C-190-32/L BIS002N 137 BIS C-516-PU-30 BCC00P7 287
BCC M435-0000-1A-000-51X475-000 BCC06F6 299 BIS C-191-05/L BIS002P 137 BIS C-517-PVC-01 BCC00P8 282
BCC M435-0000-1A-000-55X450-000 BCC06Y6 299 BIS C-191-11/L BIS002R 137 BIS C-517-PVC-05 BCC00P9 282
BCC M435-0000-2A-000-41X575-000 BCC06YA 303 BIS C-300-HG1 BAM012A 324 BIS C-517-PVC-10 BCC00PA 282
BCC M435-000-1A-000-41X575-000 BCC06ZF 303 BIS C-300-PU1-01 BIS00P5 140 BIS C-518-PVC-01 BCC00PC 282
BCC M474-0000-1D-000-51X475-000 BCC03Y1 292 BIS C-300-PU1-05 BIS005Z 140 BIS C-518-PVC-05 BCC00PE 282

■ www.balluff.com 383
Alphanumeric Directory
Sorted by part number

Part number Ordering Page Part number Ordering Page Part number Ordering Page
code code code
BIS C-518-PVC-10 BCC00PF 282 BIS C-873-1-008-X-002 175 BIS L-870-1-008-X-002 233
BIS C-520-PVC-05 BCC00PJ 283, BIS C-873-1-008-X-003 175 BIS L-870-1-008-X-003 233
287 BIS C-873-1-008-X-004 BAE00E8 175 BIS L-870-1-008-X-004 BAE00EA 233
BIS C-521-PVC-02 BCC00PK 284 BIS C-873-1-008-X-005 175 BIS L-870-1-008-X-005 233
BIS C-522-PVC-02 BCC00PL 285 BIS L-100-01/L BIS0033 192 BIS L-871-1-008-X-000 BAE00CN 233
BIS C-523-PU-05 BCC00PN 284 BIS L-100-05/L-RO BIS0035 195 BIS L-871-1-008-X-001 233
BIS C-523-PU1-05 BCC00PP 284 BIS L-101-01/L BIS0036 193 BIS L-871-1-008-X-002 233
BIS C-524-PVC-01,5 BCC00PR 285 BIS L-101-05/L-RO BIS0038 195 BIS L-871-1-008-X-003 233
BIS C-526-PU-00,6 BCC0C5J 293 BIS L-102-01/L BIS0039 193 BIS L-871-1-008-X-004 233
BIS C-600-007-650-00-KL1 BIS008U 158 BIS L-102-05/L-RO BIS003C 195 BIS L-871-1-008-X-005 233
BIS C-600-007-650-02-KL1 BIS008W 158 BIS L-103-05/L BIS003E 193 BIS L-873-1-008-X-000 BAE00CH 233
BIS C-600-007-654-00-KL1 159 BIS L-103-05/L-RO BIS003F 195 BIS L-873-1-008-X-001 BAE00EJ 233
BIS C-600-007-670-00-KL1 BIS0092 159 BIS L-103-05/L-ZC1 BIS00ZY 235 BIS L-873-1-008-X-002 233
BIS C-6002-019-650-03-KL2 BIS0099 162 BIS L-130-05/L-SA1 BIS003L 193 BIS L-873-1-008-X-003 233
BIS C-6002-019-650-03-ST11 BIS009A 162 BIS L-150-05/A BIS003N 193 BIS L-873-1-008-X-004 BAE00EA 233
BIS C-6002-019-654-03-ST11 BIS009F 163 BIS L-200-03/L BIS003R 195 BIS L-873-1-008-X-005 233
BIS C-6002-019-655-03-KL2 BIS009H 163 BIS L-201-03/L BIS003T 195 BIS M-101-01/L BIS003Y 45
BIS C-6002-019-655-03-ST11 BIS009J 163 BIS L-202-03/L BIS003U 195 BIS M-102-01/L BIS003Z 47
BIS C-6002-019-670-03-KL2 BIS009K 163 BIS L-203-03/L BIS003W 195 BIS M-105-01/A BIS0040 42
BIS C-6002-028-650-03-KL2 BIS009L 162 BIS L-203-ZH1 BAM012H 235 BIS M-105-02/A BIS0042 42
BIS C-6002-028-650-03-ST11 BIS009M 162 BIS L-300-S115 BIS004R 197 BIS M-107-03/L-H200 BIS00LC 61
BIS C-6003-025-650-03-ST12 BIS009N 166 BIS L-301-S115 BIS004T 199 BIS M-108-02/L BIS0043 50
BIS C-6003-025-654-03-ST12 167 BIS L-302-S115 BIS004U 203 BIS M-108-20/A BIS0111 50
BIS C-6003-025-655-03-ST12 BIS009R 167 BIS L-303-S115 BIS004Y 201 BIS M-110-02/L BIS0044 43
BIS C-6003-025-670-03-ST12 BIS009T 167 BIS L-304-S115 BIS004Z 204 BIS M-111-02/L BIS0045 45
BIS C-6005-027-650-05-ST4 BIS00N7 161 BIS L-306-S115 BIS00RN 205 BIS M-112-02/L BIS0046 47
BIS C-6008-048-650-06-ST23 BIS00K3 172 BIS L-350-S115 BIS0051 207 BIS M-115-03/A BIS00KM 51
BIS C-6022-019-050-03-ST10 BIS00AL 165 BIS L-380-02/BU-PU1-00,15 BIS00JT 209 BIS M-115-03/A-SA2 BIS00RZ 51
BIS C-6022-019-050-03-ST14 BIS00AM 165 BIS L-380-02/BU-PU1-00,5 BIS00JU 209 BIS M-116-03/A BIS00UC 43
BIS C-6022-028-050-03-ST10 BIS00AP 165 BIS L-380-05/BU-PU1-00,15 BIS00JW 209 BIS M-116-08/A BIS00UE 43
BIS C-6022-028-050-03-ST14 BIS00AR 165 BIS L-380-05/BU-PU1-00,5 BIS00JY 209 BIS M-120-01/L BIS0047 51
BIS C-6023-025-050-03-ST13 BIS00AT 169 BIS L-380-10/BU-PU1-00,5 BIS00JZ 209 BIS M-122-01/A BIS0048 42
BIS C-6026-034-050-06-ST19 BIS00AU 170 BIS L-380-ST/10 BIS00K1 208 BIS M-122-01/A-ZC1 BIS0049 53
BIS C-6027-039-050-06-ST19 BIS00AY 171 BIS L-400-035-001-00-S115 BIS00C5 214 BIS M-122-01/A-ZC1 BIS0049 127
BIS C-6028-048-050-06-ST22 BIS00K4 173 BIS L-400-035-001-02-S115 BIS00C6 214 BIS M-122-02/A BIS004A 42
BIS C-6028-048-050-06-ST28 BIS00TU 173 BIS L-400-035-002-00-S115 BIS00C7 215 BIS M-122-02/A-SA2 BIS00T1 54
BIS C-60R-001-08P-PU-05 BIS00H6 156 BIS L-400-035-002-02-S115 BIS00C8 215 BIS M-122-02/A-ZC1 BIS004C 53
BIS C-60R-001-08P-PU-10 BIS00H7 156 BIS L-400-035-003-00-S115 BIS00C9 215 BIS M-130-03/L BIS00YL 43
BIS C-60R-001-08P-PU-20 BIS00H8 156 BIS L-400-035-003-02-S115 BIS00CA 215 BIS M-130-07/L BIS00YK 43
BIS C-60R-002-08P-PU-05 BIS00HC 156 BIS L-400-035-004-00-S115 BIS00CC 215 BIS M-132-03/L BIS00YF 44
BIS C-60R-002-08P-PU-10 BIS00HE 156 BIS L-400-043-001-02-S115 BIS00CH 218 BIS M-132-03/L-HAT BIS00YE 60
BIS C-60R-002-08P-PU-20 BIS00TC 156 BIS L-400-043-002-02-S115 BIS00CJ 219 BIS M-132-10/L BIS00YC 45
BIS C-60R-003-08P-PU-05 BIS00HH 156 BIS L-400-043-003-02-S115 BIS00CK 219 BIS M-132-10/L-HAT BIS00YA 60
BIS C-60R-003-08P-PU-10 BIS00HJ 156 BIS L-400-043-004-02-S115 BIS00CL 219 BIS M-133-02/A BIS00Y9 45
BIS C-60R-003-08P-PU-20 156 BIS L-405-033-001-05-MU BIS00CM 211 BIS M-134-10/L-HAT BIS00Y7 60
BIS C-61R-001-08P-PU-05 BIS00HL 157 BIS L-405-033-002-05-MU BIS00CN 212 BIS M-135-02/L BIS00Y6 49
BIS C-620-007-050-00-ST2 BIS00AZ 159 BIS L-405-033-003-05-MU BIS00CP 213 BIS M-135-03/L BIS00Y5 49
BIS C-620-007-050-02-ST2 BIS00KW 159 BIS L-405-033-004-05-MU BIS00CR 213 BIS M-135-03/L-HAT BIS00Y4 61
BIS C-701-A BAE0047 178 BIS L-405-037-001-05-MU BIS00CT 211 BIS M-135-07/L BIS00Y3 49
BIS C-701-A BAE0047 249 BIS L-405-037-002-05-MU BIS00CU 212 BIS M-135-07/L-HAT BIS00Y2 61
BIS C-702-A BAE0048 178 BIS L-405-037-003-05-MU BIS00CW 213 BIS M-136-03/L BIS00W9 51
BIS C-702-A BAE0048 249 BIS L-405-037-004-05-MU BIS00CY 213 BIS M-136-03/L-HAT BIS00Y1 61
BIS C-703-A BAE0049 324 BIS L-409-045-001-07-S4 BIS00CZ 216 BIS M-140-02/A-M6 BIS00M9 57
BIS C-720-01-03 BAE004C 181 BIS L-409-045-002-07-S4 BIS00E0 217 BIS M-140-02/A-M8 BIS00M8 57
BIS C-810-0-003 BAE0088 179 BIS L-409-045-003-07-S4 BIS00E1 217 BIS M-142-02/A-M6-GY BIS00PT 55
BIS C-820-0-004-D BAE008C 179 BIS L-409-045-004-07-S4 BIS00E2 217 BIS M-142-02/A-M8-GY BIS00PU 55
BIS C-850 BAE0094 177 BIS L-503-PU1-05 BCC00R2 211, BIS M-142-20/A-M8-GY BIS0119 55
BIS C-851 BAE0095 177 213 BIS M-143-02/A-M6 BIS00NU 55
BIS C-852 BAE0096 177 BIS L-503-PU1-10 BCC00R3 211, BIS M-143-02/A-M8 BIS00NW 55
BIS C-853 BAE0097 177 213 BIS M-144-02/A-M6-GY BIS00R4 57
BIS C-870-1-008-X-000 BAE00C4 175 BIS L-503-PU1-15 BCC00R4 211, BIS M-144-02/A-M8-GY BIS00R5 57
BIS C-870-1-008-X-001 BAE00CR 175 213 BIS M-150-02/A BIS004F 58
BIS C-870-1-008-X-002 175 BIS L-503-PU1-20 BCC00R5 211, BIS M-151-02/A BIS004H 59
BIS C-870-1-008-X-003 175 213 BIS M-152-03/A BIS00M2 53
BIS C-870-1-008-X-004 BAE00JG 175 BIS L-6000-007-050-00-ST15 BIS00E3 221 BIS M-153-02/A BIS00P3 59
BIS C-870-1-008-X-005 175 BIS L-6002-019-050-03-ST11 BIS00E6 223 BIS M-153-20/A BIS010R 59
BIS C-871-1-008-X-000 BAE00J6 175 BIS L-6003-025-050-03-ST12 BIS00E7 225 BIS M-154-03/A BIS00P1 53
BIS C-871-1-008-X-001 175 BIS L-6020-007-050-00-ST15 BIS00E8 221 BIS M-155-20/A BIS0117 59
BIS C-871-1-008-X-002 175 BIS L-6022-019-050-03-ST14 BIS00EC 223 BIS M-156-20/A BIS0112 59
BIS C-871-1-008-X-003 175 BIS L-6023-025-050-03-ST13 BIS00EE 225 BIS M-191-02/A BIS00NZ 53
BIS C-871-1-008-X-004 175 BIS L-6026-034-050-06-ST19 BIS00EF 226 BIS M-300-001-S115 BIS0053 67
BIS C-871-1-008-X-005 175 BIS L-6027-039-050-06-ST19 BIS00EH 227 BIS M-300-003-S115 BIS0054 67
BIS C-873-1-008-X-000 BAE00CK 175 BIS L-870-1-008-X-000 BAE00A2 233 BIS M-301-001-S115 BIS0055 73
BIS C-873-1-008-X-001 175 BIS L-870-1-008-X-001 BAE00K4 233 BIS M-301-003-S115 BIS0056 73

384
Alphanumeric Directory
Sorted by part number

Part number Ordering Page Part number Ordering Page Part number Ordering Page
code code code
BIS M-302-001-S115 BIS0057 63 BIS M-871-1-008-X-005 125 BIS Z-501-PU1-02/M BCC00R8 280
BIS M-302-003-S115 BIS0059 63 BIS M-873-1-008-X-000 BAE00CA 125 BIS Z-501-PU1-05/E BCC00R9 281
BIS M-304-001-S115 BIS005A 65 BIS M-873-1-008-X-001 BAE00F0 125 BIS Z-501-PU1-05/M BCC00RA 280
BIS M-304-003-S115 BIS008P 65 BIS M-873-1-008-X-002 125 BIS Z-501-PU1-10/E BCC00RC 281
BIS M-305-001-S115 BIS00NK 87 BIS M-873-1-008-X-003 BAE00H9 125 BIS Z-501-PU1-20/E BCC00RF 281
BIS M-307-001-S115 BIS00P2 87 BIS M-873-1-008-X-004 BAE00E9 125 BIS Z-501-PU1-25/E BCC00RH 281
BIS M-340-001-S115* BIS00N6 95 BIS M-873-1-008-X-005 125 BIS Z-501-PU1-50/E BCC00RJ 281
BIS M-341-001-S115 BIS00M6 77 BIS S-108-32/L BIS004J 239 BIS Z-502-PU1-00,5/M BCC00RK 280
BIS M-341-003-S115 BIS00R3 77 BIS S-108-42/L BIS004K 239 BIS Z-502-PU1-01/M BCC00RL 280
BIS M-350-001-S115* BIS00LZ 95 BIS S-108-52/L BIS004L 239 BIS Z-502-PU1-02/M BCC00RM 280
BIS M-351-001-S115 BIS005C 75 BIS S-150-42/A BIS004N 239 BIS Z-502-PU1-05/E BCC00RP 281
BIS M-351-003-S115 BIS00KU 75 BIS S-150-52/A BIS004P 239 BIS Z-502-PU1-05/M BCC00RR 280
BIS M-352-001-S115 BIS00NY 86 BIS S-301-S115 BIS005F 241 BIS Z-502-PU1-10/E BCC00RU 281
BIS M-370-000-A02 BIS00WN 101 BIS S-302-S115 BIS005R 241 BIS Z-502-PU1-20/E BCC00RY 281
BIS M-371-000-A01 BIS00WM 103 BIS S-303-S115 BIS005T 241 BIS Z-502-PU1-25/E BCC00RZ 281
BIS M-372-000-A01 BIS00WL 105 BIS S-6002-019-050-03-ST11 BIS00F3 243 BIS Z-502-PU1-50/E BCC00T0 281
BIS M-373-000-A01 BIS00WK 107 BIS S-6003-025-050-03-ST12 BIS00F4 245 BIS Z-AK-001-PU1-03 BCC00T2 324
BIS M-400-007-001-00-S115 BIS00EJ 69 BIS S-6022-019-050-03-ST14 BIS00F5 243 BIS Z-EL-001-Ethernet BAE003U 231
BIS M-400-007-002-00-S115 BIS00EK 71 BIS S-6023-025-050-03-ST13 BIS00F6 245 BIS Z-EL-002-RS232 BAE003W 231
BIS M-400-045-001-07-S4 BIS00LH 69 BIS S-6026-034-050-06-ST19 BIS00F7 246 BIS Z-GW-001-IND BAE00JJ 123
BIS M-400-045-002-07-S4 BIS00LJ 71 BIS S-6027-039-050-06-ST19 BIS00F8 247 BIS Z-GW-001-PBS BAE00JK 123
BIS M-400-072-001-07-S4 BIS0108 69 BIS S-810-0-003 BAE008M 249 BIS Z-GW-001-RS232 BAE00JL 123
BIS M-400-072-002-07-S4 BIS0104 71 BIS S-850 BAE0098 249 BIS Z-GW-001-TCP BAE00JM 123
BIS M-401-007-001-00-S115 BIS00EM 79 BIS U-100-01/CA BIS00NL 24 BIS Z-HG-002 BAM012J 324
BIS M-401-045-001-07-S4 BIS00LK 79 BIS U-100-02/CA BIS00RC 24 BIS Z-HG-003 BAM012K 324
BIS M-401-072-001-07-S4 BIS0102 79 BIS U-101-04/CA BIS00WH 25 BIS Z-HW-001 BAM012L 319
BIS M-402-007-002-00-S115 BIS00EN 92 BIS U-101-04/CA-HT BIS00WF 25 BIS Z-HW-003 BAM01JK 316
BIS M-402-007-004-00-S115 BIS00RU 93 BIS U-102-05/CA BIS00WE 25 BIS Z-HW-004 BAM01KN 314
BIS M-402-045-002-07-S4 BIS00LW 92 BIS U-102-05/CA-HT BIS00WC 25 BIS Z-HW-005 BAM01YK 315
BIS M-402-045-004-07-S4 BIS00M1 93 BIS U-301-C0-TNCB BIS00P0 30 BIS Z-SP-003 BAM01LW 315
BIS M-402-045-005-07-S4-SA1 BIS00UY 93 BIS U-301-C1-TNCB BIS00TY 31 BIS Z-ZA-001 BAM012N 127,
BIS M-402-072-002-07-S4 BIS0105 92 BIS U-302-C0-TNCB BIS00TZ 31 235
BIS M-402-072-004-07-S4 BIS0106 93 BIS U-302-C1-TNCB BIS00U0 31 BIS-C-522-PVC-02 BCC00PL 272
BIS M-407-039-003-06-S115 BIS00EP 115 BIS U-500-EF-01 BAM01HL 272
BIS M-410-067-001-04-S92 BIS00W1 83 BIS U-500-EF-02 BAM01HM 272 BKS
BIS M-410-068-001-00-S115 BIS00W2 83 BIS U-500-EF-05 BAM01HN 272 BKS 12-CS-01 BAM0114 111,
BIS M-410-068-001-02-S115 BIS00W3 83 BIS U-500-EF-10 BAM01HP 272 162,
BIS M-410-068-001-09-S72 BIS00W4 83 BIS U-6020-053-104-00-ST26 BIS00M7 29 164,
BIS M-411-067-001-04-S92 BIS00W5 85 BIS U-6020-059-114-00-ST26 BIS00R2 29 223,
243
BIS M-411-068-001-00-S115 BIS00W6 85 BIS U-6027-054-104-06-ST27 BIS00NA 29
BIS M-411-068-001-02-S115 BIS00W7 85 BIS U-6027-060-114-06-ST27 BIS00R1 29 BKS 23-CS-00 BAM012P 164
BIS M-411-068-001-09-S72 BIS00W8 85 BIS U-6028-048-104-06-ST28 BIS00ZU 29 BKS-7/8-CS-00-A BAM012T 168,
BIS M-440-039-001-06-ST2* BIS00PZ 97 BIS U-6028-048-114-06-ST28 BIS00ZW 29 295
BIS M-450-039-001-06-ST2* BIS00R0 97 BIS U-620-067-101-04-ST30 BIS00Z8 27 BKS-S 45-00 BCC011M 286
BIS M-451-007-001-00-S115 BIS00ER 81 BIS U-620-067-111-04-ST30 BIS00Z6 27 BKS-S 46-00 BCC011N 287
BIS M-451-045-001-07-S4 BIS00LM 81 BIS U-620-068-101-00-ST29 BIS00Z4 27 BKS-S 52-00 BCC00T6 287
BIS M-451-072-001-07-S4 BIS0103 81 BIS U-620-068-111-00-ST29 BIS00Z2 27 BKS-S 83-00 BCC00T9 289
BIS M-500-PVC-07-A01/02 BIS00WJ 100 BIS U-626-069-101-06-ST32 BIS00Z0 27 BKS-S 84-00 BCC00TA 289
BIS M-6000-007-050-00-ST15 BIS00N1 109 BIS U-626-069-111-06-ST32 BIS00YY 27 BKS-S 86-00 BCC00TC 289
BIS M-6000-007-050-00-ST24 BIS00J0 109 BIS U-870-1-008-X-000 BAE00EE 33 BKS-S115-00 BCC00YA 288
BIS M-6002-019-050-03-ST11 BIS00EW 111 BIS U-870-1-008-X-000-1 BAE00JR 33 BKS-S115-PU-02 BCC00YE 288
BIS M-6003-025-050-03-ST12 BIS00EY 113 BIS U-870-1-008-X-001 BAE00J8 33 BKS-S115-PU-05 BCC00YF 288
BIS M-6008-048-050-06-ST23 BIS00L7 117 BIS V-6102-019-C001 BIS00T3 121, BKS-S115-PU-10 BCC00YH 288
BIS M-6022-019-050-03-ST14 BIS00F0 111 229 BKS-S115-PU-15 BCC00YJ 288
BIS M-6023-025-050-03-ST13 BIS00F1 113 BIS V-6110-063-C002 BIS00U9 121, BKS-S116-PU-02 BCC00YU 288
BIS M-6026-034-050-06-ST19 BIS00F2 114 229 BKS-S116-PU-05 BCC00YW 288
BIS M-6028-048-050-06-ST22 BIS00KZ 117 BIS V-6111-073-C003 BIS010P 121, BKS-S116-PU-10 BCC00YY 288
BIS M-6028-048-050-06-ST28 BIS00TW 117 229 BKS-S116-PU-15 BCC00YZ 288
BIS M-620-067-A01-04-ST30 BIS00ZK 99 BIS VL-300-001-S4 BIS00UL 197
BIS M-620-068-A01-00-ST29 BIS00ZH 99 BIS VL-301-001-S4 BIS00U6 199 BMS
BIS M-626-069-A01-06-ST32 BIS00ZA 99 BIS VL-302-001-S4 BIS00UF 203 BMS CC-M-D12-B-00 BAM002Z 317
BIS M-688-001 BIS00HM 118 BIS VL-304-001-S4 BIS00UH 204 BMS CS-M-D12-IZ BAM0031 316
BIS M-699-052-050-03-ST11 BIS00LY 119 BIS VL-306-001-S4 BIS00UJ 205 BMS CS-M-D14-IZ BAM01Z7 317
BIS M-870-1-008-X-000 BAE00A1 125 BIS VL-350-001-S4 BIS00UK 207 BMS CS-M-S25-DX15-00 BAM01YP 329
BIS M-870-1-008-X-001 125 BIS VM-300-001-S4 BIS00RF 67 BMS CUJ-M-S25-D045-00 BAM01YT 329
BIS M-870-1-008-X-002 125 BIS VM-301-001-S4 BIS00T0 73 BMS CU-M-D12-A040-00 BAM002W 317
BIS M-870-1-008-X-003 125 BIS VM-305-001-S4 BIS00T9 91 BMS RS-M-D12-0150-00 BAM002R 317
BIS M-870-1-008-X-004 BAE00CC 125 BIS VM-306-001-S4 BIS00T7 89
BIS M-870-1-008-X-005 125 BIS VM-307-001-S4 BIS00T8 89 BNI
BIS M-871-1-008-X-000 BAE00CM 125 BIS VM-341-001-S4 BIS00TA 77 BNI CCL-502-100-Z001 BNI0040 301
BIS M-871-1-008-X-001 125 BIS VM-351-001-S4 BIS00T2 75 BNI DNT-502-100-Z001 BNI005A 300
BIS M-871-1-008-X-002 125 BIS VM-352-001-S4 BIS0076 91 BNI EIP-502-105-Z015 BNI004A 300
BIS M-871-1-008-X-003 125 BIS Z-501-PU1-00,5/M BCC00R6 280 BNI EIP-508-105-Z015 BNI006A 300
BIS M-871-1-008-X-004 125 BIS Z-501-PU1-01/M BCC00R7 280 BNI EIP-950-000-Z009 BNI000F 310

■ www.balluff.com 385
Alphanumeric Directory
Sorted by part number,
sorted by ordering code

Part number Ordering Page


code
BNI PBS-502-001-Z001 BNI003K 300
BNI PBS-502-101-Z001 BNI005R 301
BNI PBS-504-001-K008 BNI0030 301 Sorted by
BNI PBS-507-001-Z011 BNI003P 301
BNI PNT-502-105-Z015 BNI004U 300 ordering code
BNI PNT-508-105-Z015 BNI005H 300
BNI TCP-951-000-E028 BNI005E 311
BNI TCP-952-000-E029 BNI0067 311 Ordering Part number Page
code
BVS
BVS ID-3-001-E BVS0001 261 BAE
BVS ID-3-003-E BVS000T 261 BAE0001 BAE-PS-XA-1W-24-007-001 349
BVS ID-3-005-E BVS001R 261 BAE0002 BAE-PS-XA-1W-24-100-004 349
BVS ID-3-007-E BVS000Y 261 BAE0003 BAE-PS-XA-1W-24-200-005 349
BVS ID-3-101-E BVS0019 261 BAE0004 BAE-PS-XA-1W-24-012-002 349
BVS ID-3-103-E BVS001A 261 BAE0005 BAE-PS-XA-1W-24-025-002 349
BVS ID-3-105-E BVS001C 261 BAE0006 BAE-PS-XA-1W-24-050-003 349
BVS OI-3-001-E BVS0003 263 BAE0007 BAE-PS-XA-3Y-24-050-009 349
BVS OI-3-002-E BVS0004 263 BAE0008 BAE-PS-XA-3Y-24-100-006 349
BVS OI-3-003-E BVS0005 263 BAE0009 BAE-PS-XA-3Y-24-200-007 349
BVS OI-3-004-E BVS0006 263 BAE000E BAE LX-VS-HR025 334
BVS OI-3-005-E BVS000E 263 BAE000F BAE LX-VS-HR050 334
BVS OI-3-006-E BVS000C 263 BAE000H BAE LX-VS-HR100 335
BVS OI-3-051-E BVS000J 265 BAE000J BAE LX-VS-RR100 338
BVS OI-3-052-E BVS000P 265 BAE000K BAE LX-VS-RI100 339
BVS OI-3-053-E BVS000K 265 BAE0036 BAE-PS-XA-1W-12-015-001 349
BVS OI-3-054-E BVS000N 265 BAE0039 BAE-PS-XA-1W-12-025-002 349
BVS OI-3-055-E BVS000L 265 BAE003E BAE-PS-XA-1W-12-050-002 349
BVS OI-3-056-E BVS000R 265 BAE003H BAE-PS-XA-1W-12-100-003 349
BVS OI-3-057-E BVS000W 265 BAE003J BAE-PS-XA-1W-24-038-003 349
BVS OI-3-101-E BVS0014 263 BAE003K BAE-PS-XA-1W-48-025-003 349
BVS OI-3-103-E BVS0012 263 BAE003L BAE-PS-XA-1W-48-050-004 349
BVS OI-3-105-E BVS0013 263 BAE003M BAE-PS-XA-1W-48-100-005 349
BVS OI-3-151-E BVS0015 265 BAE003R BAE-PS-XA-3Y-24-400-010 349
BVS OI-3-153-E BVS0017 265 BAE003U BIS Z-EL-001-Ethernet 231
BVS OI-3-155-E BVS0016 265 BAE003W BIS Z-EL-002-RS232 231
BVS UR-3-001-E BVS001M 267 BAE0047 BIS C-701-A 178
BVS UR-3-003-E BVS001N 267 BAE0047 BIS C-701-A 249
BVS UR-3-005-E BVS001L 267 BAE0048 BIS C-702-A 178
BVS UR-3-007-E BVS001P 267 BAE0048 BIS C-702-A 249
BVS UR-3-101-E BVS001H 267 BAE0049 BIS C-703-A 324
BVS UR-3-103-E BVS001J 267 BAE004C BIS C-720-01-03 181
BVS UR-3-105-E BVS001F 267 BAE0088 BIS C-810-0-003 179
BVS Z-MB-01 BAM00WN 327 BAE008C BIS C-820-0-004-D 179
BAE008M BIS S-810-0-003 249
Sonstiges BAE0094 BIS C-850 177
11023834 FHW0003 124, BAE0095 BIS C-851 177
174, BAE0096 BIS C-852 177
232, BAE0097 BIS C-853 177
315 BAE0098 BIS S-850 249
11023836 FHW0004 124, BAE00A1 BIS M-870-1-008-X-000 125
174, BAE00A2 BIS L-870-1-008-X-000 233
232, BAE00AM BAE LX-VS-DR090 346
315 BAE00AN BAE LX-VS-RW100 339
Akku-BIS C-81. 2,4V 1500 MAH 125997 249 BAE00AP BAE LX-VS-LR085 340
MONTAGESCHLUESSEL BIS CODETRAEGER 710691 135 BAE00AR BAE LX-VS-LW085 341
BAE00AT BAE LX-VS-LI085 341
BAE00AW BAE LX-VS-LW170 341
BAE00AY BAE LX-VS-LI170 341
BAE00AZ BAE LX-VS-LR170 340
BAE00C4 BIS C-870-1-008-X-000 175
BAE00C5 BAE LX-VS-HR150 336
BAE00CA BIS M-873-1-008-X-000 125
BAE00CC BIS M-870-1-008-X-004 125
BAE00CH BIS L-873-1-008-X-000 233
BAE00CK BIS C-873-1-008-X-000 175
BAE00CM BIS M-871-1-008-X-000 125
BAE00CN BIS L-871-1-008-X-000 233
BAE00CR BIS C-870-1-008-X-001 175
BAE00E8 BIS C-873-1-008-X-004 175
BAE00E9 BIS M-873-1-008-X-004 125
BAE00EA BIS L-870-1-008-X-004 233
BAE00EA BIS L-873-1-008-X-004 233
BAE00EE BIS U-870-1-008-X-000 33

386
Alphanumeric Directory
Sorted by ordering code

Ordering Part number Page Ordering Part number Page Ordering Part number Page
code code code
BAE00EH BAE PD-VS-002-E 268 BAM012L BIS Z-HW-001 319 BCC00R8 BIS Z-501-PU1-02/M 280
BAE00EJ BIS L-873-1-008-X-001 233 BAM012N BIS Z-ZA-001 127, BCC00R9 BIS Z-501-PU1-05/E 281
BAE00EK BAE PS-XA-1W-24-050-013 351 235 BCC00RA BIS Z-501-PU1-05/M 280
BAE00EN BAE PS-XA-1W-24-038-601 351 BAM012P BKS 23-CS-00 164 BCC00RC BIS Z-501-PU1-10/E 281
BAE00EP BAE PS-XA-1W-24-038-602 351 168, BCC00RF BIS Z-501-PU1-20/E 281
BAM012T BKS-7/8-CS-00-A
BAE00ER BAE PS-XA-1W-24-038-603 351 295 BCC00RH BIS Z-501-PU1-25/E 281
BAE00ET BAE PS-XA-1W-24-080-604 351 BAM01A7 BAM OF-VS-001-D-RX100 338 BCC00RJ BIS Z-501-PU1-50/E 281
BAE00EU BAE PS-XA-1W-24-100-014 351 BAM01A8 BAM PC-AE-002-1 330 BCC00RK BIS Z-502-PU1-00,5/M 280
BAE00F0 BIS M-873-1-008-X-001 125 BAM01AC BAM MB-XA-003-B03-1 327 BCC00RL BIS Z-502-PU1-01/M 280
BAE00FL BAE PS-XA-1W-24-080-605 351 BAM01AE BAM MB-XA-002-B02-1 327 BCC00RM BIS Z-502-PU1-02/M 280
BAE00FM BAE LX-VS-RW100-S 339 BAM01HL BIS U-500-EF-01 272 BCC00RP BIS Z-502-PU1-05/E 281
BAE00FN BAE LX-VS-RI100-S 339 BAM01HM BIS U-500-EF-02 272 BCC00RR BIS Z-502-PU1-05/M 280
BAE00FP BAE LX-VS-RR100-S 338 BAM01HN BIS U-500-EF-05 272 BCC00RU BIS Z-502-PU1-10/E 281
BAE00FR BAE LX-VS-HI100 335 BAM01HP BIS U-500-EF-10 272 BCC00RY BIS Z-502-PU1-20/E 281
BAE00FT BAE LX-VS-SR030 343 BAM01JK BIS Z-HW-003 316 BCC00RZ BIS Z-502-PU1-25/E 281
BAE00FW BAE PS-XA-1W-24-038-607 351 BAM01KN BIS Z-HW-004 314 BCC00T0 BIS Z-502-PU1-50/E 281
BAE00FY BAE PS-XA-1W-24-080-606 351 BAM01LW BIS Z-SP-003 315 BCC00T2 BIS Z-AK-001-PU1-03 324
BAE00H0 BAE LX-VS-SR018 343 BAM01MY BAM MB-XA-010-B07-4 320 BCC00T6 BKS-S 52-00 287
BAE00H1 BAE LX-VS-SI018 343 BAM01RR BAM PC-VS-008-1 331 BCC00T9 BKS-S 83-00 289
BAE00H2 BAE LX-VS-SI030 343 BAM01TM BAM MC-XA-016-Q40-1 318 BCC00TA BKS-S 84-00 289
BAE00H9 BIS M-873-1-008-X-003 125 BAM01UH BAM MB-XA-012-B09-4 320 BCC00TC BKS-S 86-00 289
BAE00J6 BIS C-871-1-008-X-000 175 BAM01W4 BAM MC-XA-021-M18-2 323 BCC00YA BKS-S115-00 288
BAE00J8 BIS U-870-1-008-X-001 33 BAM01W5 BAM MC-XA-021-M30-2 323 BCC00YE BKS-S115-PU-02 288
BAE00J9 BAE LX-VS-OR50 345 BAM01WJ BAM MC-XA-021-M18-4 323 BCC00YF BKS-S115-PU-05 288
BAE00JA BAE LX-VS-OR100 345 BAM01WK BAM MC-XA-021-M30-4 323 BCC00YH BKS-S115-PU-10 288
BAE00JC BAE LX-VS-HR200 337 BAM01WL BAM MC-XA-021-M18-A 323 BCC00YJ BKS-S115-PU-15 288
BAE00JE BAE LX-VS-HI200 337 BAM01WM BAM MC-XA-021-M30-A 323 BCC00YU BKS-S116-PU-02 288
BAE00JF BAE LX-VS-HR100-E 337 BAM01Y3 BAM MC-XA-018-B04-4 320 BCC00YW BKS-S116-PU-05 288
BAE00JG BIS C-870-1-008-X-004 175 BAM01Y8 BAM PC-AM-010-4 320 BCC00YY BKS-S116-PU-10 288
BAE00JJ BIS Z-GW-001-IND 123 BAM01YK BIS Z-HW-005 315 BCC00YZ BKS-S116-PU-15 288
BAE00JK BIS Z-GW-001-PBS 123 BAM01YP BMS CS-M-S25-DX15-00 329 BCC011M BKS-S 45-00 286
BAE00JL BIS Z-GW-001-RS232 123 BAM01YT BMS CUJ-M-S25-D045-00 329 BCC011N BKS-S 46-00 287
BAE00JM BIS Z-GW-001-TCP 123 BAM01Z7 BMS CS-M-D14-IZ 317 BCC02M8 BCC M313-0000-10-001-PX0334-020 309
BAE00JR BIS U-870-1-008-X-000-1 33 BAM0206 BAM FK-VS-002-03-1 330 BCC02M9 BCC M313-0000-10-001-PX0334-050 309
BAE00K4 BIS L-870-1-008-X-001 233 BCC02MA BCC M313-0000-10-001-PX0334-100 309
BAE00KE BAE LX-XO-PL018-L1-S4 347 BCC BCC02NU BCC M313-0000-10-001-VX8334-020 309
BAE00KF BAE LX-VS-SR012 342 BCC00N1 BIS C-505-PU-01 283 BCC02NW BCC M313-0000-10-001-VX8334-050 309
BAE00KP BAE LX-VS-HI150 336 BCC00N2 BIS C-505-PU-05 283 BCC02NY BCC M313-0000-10-001-VX8334-100 309
BAE00KR BAE LX-VS-HI050 335 BCC00N3 BIS C-505-PU-10 283 BCC032F BCC M415-0000-1A-003-PX0434-020 305,
BAE00KZ BAE LX-XO-PL018-L2-S4 347 BCC00N4 BIS C-505-PU1-05 283 309
BCC00N5 BIS C-505-PU1-10 283 BCC032H BCC M415-0000-1A-003-PX0434-050 305,
BAM BCC00N6 BIS C-506-PU-01 283 309
BAM002R BMS RS-M-D12-0150-00 317 BCC00N7 BIS C-506-PU-05 283 BCC032J BCC M415-0000-1A-003-PX0434-100 305,
BAM002W BMS CU-M-D12-A040-00 317 BCC00N8 BIS C-506-PU-10 283 309
BAM002Z BMS CC-M-D12-B-00 317 BCC00N9 BIS C-506-PU1-05 283 BCC032K BCC M415-0000-1A-014-PS0434-020 278
BAM0031 BMS CS-M-D12-IZ 316 BCC00NA BIS C-506-PU1-10 283 BCC032L BCC M415-0000-1A-014-PS0434-050 278
BAM00EM BES 14,5-BS-1 322 BCC00P4 BIS C-516-PU-05 287 BCC032M BCC M415-0000-1A-014-PS0434-100 278
BAM00ET BES 16,0-BS-1 322 BCC00P5 BIS C-516-PU-10 287 BCC0331 BCC M425-0000-1A-014-PS0434-020 278
BAM00EY BES 18,0-HW-1 321 BCC00P6 BIS C-516-PU-20 287 BCC0332 BCC M425-0000-1A-014-PS0434-050 278
BAM00F2 BES 18,0-BS-1 322 BCC00P7 BIS C-516-PU-30 287 BCC0333 BCC M425-0000-1A-014-PS0434-100 278
BAM00F7 BES 18,0-KB-3 321 BCC00P8 BIS C-517-PVC-01 282 BCC0367 BCC M415-0000-1A-003-VX8434-020 309
BAM00F9 BES 18,0-KB-3-F-SA1 321 BCC00P9 BIS C-517-PVC-05 282 BCC0368 BCC M415-0000-1A-003-VX8434-050 309
BAM00FT BES 18.0-KH-2S 322 BCC00PA BIS C-517-PVC-10 282 BCC0369 BCC M415-0000-1A-003-VX8434-100 309
BAM00HH BES 30,0-HW-1 321 BCC00PC BIS C-518-PVC-01 282 BCC036A BCC M415-0000-1A-014-VS8434-020 278
BAM00HN BES 30,0-BS-1 322 BCC00PE BIS C-518-PVC-05 282 BCC036C BCC M415-0000-1A-014-VS8434-050 278
BAM00HU BES 30,0-KB-3-F 321 BCC00PF BIS C-518-PVC-10 282 BCC036E BCC M415-0000-1A-014-VS8434-100 278
BAM00J4 BES 30,0-KH-2L 322 BCC00PJ BIS C-520-PVC-05 283, BCC036T BCC M425-0000-1A-014-VS8434-020 278
BAM00J6 BES 30,0-KH-2S 322 287 BCC036U BCC M425-0000-1A-014-VS8434-050 278
BAM00JT BES HS-01-P1-C16/Q40 319 BCC00PK BIS C-521-PVC-02 284 BCC036W BCC M425-0000-1A-014-VS8434-100 278
BAM00JU BES HS-01-P1-C8/Q40 319 BCC00PL BIS C-522-PVC-02 285 BCC039H BCC M415-M414-3A-304-PX0434-003 274
BAM00JW BES Q40-HW-1 318 BCC00PL BIS-C-522-PVC-02 272 BCC039J BCC M415-M414-3A-304-PX0434-006 274
BAM00WN BVS Z-MB-01 327 BCC00PN BIS C-523-PU-05 284 BCC039K BCC M415-M414-3A-304-PX0434-010 274
BAM0114 BKS 12-CS-01 111, BCC00PP BIS C-523-PU1-05 284 BCC039L BCC M415-M414-3A-304-PX0434-015 274
162, BCC00PR BIS C-524-PVC-01,5 285 BCC039M BCC M415-M414-3A-304-PX0434-020 274
164, BCC00R2 BIS L-503-PU1-05 211, BCC039N BCC M415-M414-3A-304-PX0434-030 274
223, 213 BCC039P BCC M415-M414-3A-304-PX0434-050 274
243
BCC00R3 BIS L-503-PU1-10 211, BCC039R BCC M415-M424-3A-304-PX0434-003 275
213 BCC039T BCC M415-M424-3A-304-PX0434-006 275
BAM012A BIS C-300-HG1 140, BCC00R4 BIS L-503-PU1-15 211, BCC039U BCC M415-M424-3A-304-PX0434-010 275
324 213 BCC039W BCC M415-M424-3A-304-PX0434-015 275
BAM012C BIS C-300-ZA1 183 BCC00R5 BIS L-503-PU1-20 211, BCC039Y BCC M415-M424-3A-304-PX0434-020 275
BAM012H BIS L-203-ZH1 235 213 BCC039Z BCC M415-M424-3A-304-PX0434-030 275
BAM012J BIS Z-HG-002 324 BCC00R6 BIS Z-501-PU1-00,5/M 280 BCC03A0 BCC M415-M424-3A-304-PX0434-050 275
BAM012K BIS Z-HG-003 324 BCC00R7 BIS Z-501-PU1-01/M 280 BCC03A8 BCC M425-M414-3A-304-PX0434-003 274

■ www.balluff.com 387
Alphanumeric Directory
Sorted by ordering code

Ordering Part number Page Ordering Part number Page Ordering Part number Page
code code code
BCC03A9 BCC M425-M414-3A-304-PX0434-006 274 BCC07WZ BDN T-DTE-AD-01 304 BIS0004 BIS C-103-05/A 134
BCC03AA BCC M425-M414-3A-304-PX0434-010 274 BCC084R BCC M414-0000-2A-068-VS24N7-020 298 BIS0006 BIS C-104-11/A 136
BCC03AC BCC M425-M414-3A-304-PX0434-015 274 BCC084T BCC M414-0000-2A-068-VS24N7-050 298 BIS0007 BIS C-104-32/A 136
BCC03AE BCC M425-M414-3A-304-PX0434-020 274 BCC084U BCC M414-0000-2A-068-VS24N7-100 298 BIS0009 BIS C-105-05/A 134
BCC03AF BCC M425-M414-3A-304-PX0434-030 274 BCC0869 BCC M474-0000-2A-000-01X475-000 279 BIS000C BIS C-108-05/L 136
BCC03AH BCC M425-M414-3A-304-PX0434-050 274 BCC0994 BCC M418-0000-1A-046-PS0825-020 308 BIS000F BIS C-108-05/L-SA2 139
BCC03AJ BCC M425-M424-3A-304-PX0434-003 275 BCC0995 BCC M418-0000-1A-046-PS0825-050 308 BIS000H BIS C-108-11/L 136
BCC03AK BCC M425-M424-3A-304-PX0434-006 275 BCC0996 BCC M418-0000-1A-046-PS0825-100 308 BIS000J BIS C-108-11/L-SA2 139
BCC03AL BCC M425-M424-3A-304-PX0434-010 275 BCC09HL BCC M418-0000-1A-046-PS0825-200 308 BIS000K BIS C-108-32/L 136
BCC03AM BCC M425-M424-3A-304-PX0434-015 275 BCC09MR BCC M415-0000-2A-R04 304 BIS000M BIS C-117-05/A 135
BCC03AN BCC M425-M424-3A-304-PX0434-020 275 BCC09N2 BCC E878-0000-Z1-41X8T4 315 BIS000N BIS C-117-05/L 135
BCC03AP BCC M425-M424-3A-304-PX0434-030 275 BCC09UY BCC A315-0000-10-030-VS85N6-020 302 BIS000R BIS C-117-11/L 135
BCC03AR BCC M425-M424-3A-304-PX0434-050 275 BCC09W0 BCC A315-0000-10-030-VS85N6-050 302 BIS000T BIS C-121-04/L 134
BCC03WZ BCC M474-0000-2D-000-51X475-000 292 BCC09W3 BCC A315-0000-10-030-VS85N6-100 302 BIS000W BIS C-121-04/L-SA1 138
BCC03Y0 BCC M484-0000-2D-000-51X475-000 293 BCC09YA BCC A315-A315-30-330-VS85N6-006 302 BIS0011 BIS C-122-04/L 134
BCC03Y1 BCC M474-0000-1D-000-51X475-000 292 BCC09YE BCC A315-A315-30-330-VS85N6-020 302 BIS0015 BIS C-122-11/L 134
BCC03Y2 BCC M484-0000-1D-000-51X475-000 293 BCC09YJ BCC A315-A315-30-330-VS85N6-050 302 BIS0017 BIS C-127-05/L 137
BCC04K6 BCC M414-E834-8G-668-PS54T2-006 293 BCC09YP BCC A315-A315-30-330-VS85N6-100 302 BIS0019 BIS C-128-05/L 135
BCC04K7 BCC M414-E834-8G-668-PS54T2-020 293 BCC09YT BCC A315-A315-30-330-VS85N6-150 302 BIS001C BIS C-128-11/L 135
BCC04K8 BCC M414-E834-8G-668-PS54T2-050 293 BCC0A08 BCC M415-0000-1A-R04 296 BIS001E BIS C-130-05/L 135
BCC04K9 BCC M414-E834-8G-668-PS54T2-100 293 BCC0A09 BCC A315-0000-2A-R04 304 BIS001H BIS C-130-05/L-SA1 138
BCC04KA BCC M414-E834-8G-668-PS54T2-200 293 BCC0A0A BCC A315-0000-1A-R04 295 BIS001Z BIS C-133-05/L 139
BCC04KC BCC M414-E834-8G-668-PS54T2-300 293 BCC0A11 BCC M415-M412-3B-329-PS72N1-003 291 BIS0020 BIS C-134-05/L-H120 139
BCC04ZJ BCC M414-E834-8G-668-PS54T2-150 293 BCC0A12 BCC M415-M412-3B-329-PS72N1-006 291 BIS0021 BIS C-134-11/L 139
BCC06F6 BCC M435-0000-1A-000-51X475-000 299 BCC0A13 BCC M415-M412-3B-329-PS72N1-010 291 BIS0028 BIS C-150-05/A 137
BCC06F7 BCC M434-0000-2A-000-51X475-000 299 BCC0A14 BCC M415-M412-3B-329-PS72N1-020 291 BIS002A BIS C-150-11/A 137
BCC06FM BCC A315-A315-30-335-PX05A5-006 307 BCC0A15 BCC M415-M412-3B-329-PS72N1-050 291 BIS002E BIS C-150-32/A 137
BCC06FN BCC A315-A315-30-335-PX05A5-020 307 BCC0AA7 BCC A315-A315-A315-T0023-000 295 BIS002K BIS C-190-05/L 137
BCC06FP BCC A315-A315-30-335-PX05A5-050 307 BCC0ACA BCC 0000-0000-00-000-PS72N1-10X 291 BIS002M BIS C-190-11/L 137
BCC06FR BCC A315-A315-30-335-PX05A5-100 307 BCC0ANA BCC M415-M415-5D-687-ES64N8-020 309 BIS002N BIS C-190-32/L 137
BCC06FT BCC A315-A315-30-335-PX05A5-150 307 BCC0ANC BCC M415-M415-5D-687-ES64N8-050 309 BIS002P BIS C-191-05/L 137
BCC06FU BCC A315-A325-30-335-PX05A5-006 307 BCC0AT8 BCC M418-0000-1A-046-PS0825-400 308 BIS002R BIS C-191-11/L 137
BCC06FW BCC A315-A325-30-335-PX05A5-020 307 BCC0C02 BCC M415-M414-3A-305-PS0434-050 276 BIS002Y BIS C-122-04/L-ZC1 183
BCC06FY BCC A315-A325-30-335-PX05A5-050 307 BCC0C03 BCC M415-M414-3A-305-PS0434-100 276 BIS0033 BIS L-100-01/L 192
BCC06FZ BCC A315-A325-30-335-PX05A5-100 307 BCC0C04 BCC M415-M414-3A-305-PS0434-200 276 BIS0035 BIS L-100-05/L-RO 195
BCC06H0 BCC A315-A325-30-335-PX05A5-150 307 BCC0C5J BIS C-526-PU-00,6 293 BIS0036 BIS L-101-01/L 193
BCC06H1 BCC A325-A315-30-335-PX05A5-006 307 BCC0C6E BCC M415-0000-1B-R01 291 BIS0038 BIS L-101-05/L-RO 195
BCC06H2 BCC A325-A315-30-335-PX05A5-020 307 BCC0C8L BCC M415-M414-3A-305-PS0434-030 276 BIS0039 BIS L-102-01/L 193
BCC06H3 BCC A325-A315-30-335-PX05A5-050 307 BCC0CR2 BCC M415-U024-8F-696-VX04T8-018 279 BIS003C BIS L-102-05/L-RO 195
BCC06H4 BCC A325-A315-30-335-PX05A5-100 307 297, BIS003E BIS L-103-05/L 193
BCC0CZW BCC A415-0000-1A-030-VS85N6-020
BCC06H5 BCC A325-A315-30-335-PX05A5-150 307 302 BIS003F BIS L-103-05/L-RO 195
BCC06H6 BCC A325-A325-30-335-PX05A5-006 307 297, BIS003L BIS L-130-05/L-SA1 193
BCC0CZY BCC A415-0000-1A-030-VS85N6-050
BCC06H7 BCC A325-A325-30-335-PX05A5-020 307 302 BIS003N BIS L-150-05/A 193
BCC06H8 BCC A325-A325-30-335-PX05A5-050 307 297, BIS003R BIS L-200-03/L 195
BCC0CZZ BCC A415-0000-1A-030-VS85N6-100
BCC06H9 BCC A325-A325-30-335-PX05A5-100 307 302 BIS003T BIS L-201-03/L 195
BCC06HA BCC A325-A325-30-335-PX05A5-150 307 297, BIS003U BIS L-202-03/L 195
BCC0E00 BCC A415-0000-2A-030-VS85N6-020
BCC06HC BCC A315-0000-10-063-PX05A5-020 306 303 BIS003W BIS L-203-03/L 195
BCC06HE BCC A315-0000-10-063-PX05A5-050 306 297, BIS003Y BIS M-101-01/L 45
BCC0E01 BCC A415-0000-2A-030-VS85N6-050
BCC06HF BCC A315-0000-10-063-PX05A5-100 306 303 BIS003Z BIS M-102-01/L 47
BCC06HH BCC A325-0000-10-063-PX05A5-020 306 BCC0E01 BCC A415-0000-2A-030-VS85N6-050 303 BIS0040 BIS M-105-01/A 42
BCC06HJ BCC A325-0000-10-063-PX05A5-050 306 BCC0E02 BCC A415-0000-2A-030-VS85N6-100 297 BIS0042 BIS M-105-02/A 42
BCC06HK BCC A325-0000-10-063-PX05A5-100 306 BCC0E02 BCC A415-0000-2A-030-VS85N6-100 303 BIS0043 BIS M-108-02/L 50
BCC06WU BCC M415-M414-3A-337-VS24N7-006 298 BCC0E03 BCC A415-A415-3A-330-VS85N6-006 297 BIS0044 BIS M-110-02/L 43
BCC06WW BCC M415-M414-3A-337-VS24N7-020 298 BCC0E04 BCC A415-A415-3A-330-VS85N6-020 297 BIS0045 BIS M-111-02/L 45
BCC06WY BCC M415-M414-3A-337-VS24N7-050 298 BCC0E05 BCC A415-A415-3A-330-VS85N6-050 297 BIS0046 BIS M-112-02/L 47
BCC06WZ BCC M415-M414-3A-337-VS24N7-100 298 BCC0E06 BCC A415-A415-3A-330-VS85N6-100 297 BIS0047 BIS M-120-01/L 51
BCC06Y0 BCC M415-M414-3A-337-VS24N7-150 298 BCC0E07 BCC A415-A415-3A-330-VS85N6-150 297 BIS0048 BIS M-122-01/A 42
BCC06Y1 BCC M415-0000-1A-068-VS24N7-020 298 BCC0E3C BCC M425-M414-3A-305-PS0434-030 277 BIS0049 BIS M-122-01/A-ZC1 53
BCC06Y2 BCC M415-0000-1A-068-VS24N7-050 298 BCC0E3E BCC M425-M414-3A-305-PS0434-050 277 BIS0049 BIS M-122-01/A-ZC1 127
BCC06Y3 BCC M415-0000-1A-068-VS24N7-100 298 BCC0E3F BCC M425-M414-3A-305-PS0434-100 277 BIS004A BIS M-122-02/A 42
BCC06Y5 BCC M434-0000-2A-000-55X450-000 299 BCC0E3H BCC M425-M414-3A-305-PS0434-200 277 BIS004C BIS M-122-02/A-ZC1 53
BCC06Y6 BCC M435-0000-1A-000-55X450-000 299 BCC0E3J BCC M415-M424-3A-305-PS0434-030 276 BIS004F BIS M-150-02/A 58
BCC06YA BCC M435-0000-2A-000-41X575-000 303 BCC0E3K BCC M415-M424-3A-305-PS0434-050 276 BIS004H BIS M-151-02/A 59
BCC06Z9 BCC M435-0000-1A-000-41X475-000 305 BCC0E3L BCC M415-M424-3A-305-PS0434-100 276 BIS004J BIS S-108-32/L 239
BCC06ZF BCC M435-000-1A-000-41X575-000 303 BCC0E3M BCC M415-M424-3A-305-PS0434-200 276 BIS004K BIS S-108-42/L 239
BCC06ZN BCC M475-0000-1A-000-01X575-000 305 BCC0E3N BCC M425-M424-3A-305-PS0434-030 277 BIS004L BIS S-108-52/L 239
BCC070F BCC A335-0000-10-000-61X5A5-000 294 BCC0E3P BCC M425-M424-3A-305-PS0434-050 277 BIS004N BIS S-150-42/A 239
BCC070K BCC A335-0000-20-000-61X5A5-000 294 BCC0E3R BCC M425-M424-3A-305-PS0434-100 277 BIS004P BIS S-150-52/A 239
BCC0714 BCC M475-0000-2B-000-01X575-000 290 BCC0E3T BCC M425-M424-3A-305-PS0434-200 277 BIS004R BIS L-300-S115 197
BCC0715 BCC M475-0000-1B-000-01X575-000 290 BCC0E7T BCC M415-E834-AG-672-ES64N8-050 308 BIS004T BIS L-301-S115 199
BCC0716 BCC M485-0000-2B-000-01X575-000 290 BCC0E7W BCC M415-E834-AG-672-ES64N8-150 308 BIS004U BIS L-302-S115 203
BCC0717 BCC M485-0000-1B-000-01X575-000 290 BIS004Y BIS L-303-S115 201
BCC0718 BCC M415-0000-2B-R01 291 BIS BIS004Z BIS L-304-S115 204
BCC07WR BDN T-DTN-DD-01 296 BIS0002 BIS C-100-05/A 135 BIS0051 BIS L-350-S115 207

388
Alphanumeric Directory
Sorted by ordering code

Ordering Part number Page Ordering Part number Page Ordering Part number Page
code code code
BIS0053 BIS M-300-001-S115 67 BIS00CN BIS L-405-033-002-05-MU 212 BIS00LM BIS M-451-045-001-07-S4 81
BIS0054 BIS M-300-003-S115 67 BIS00CP BIS L-405-033-003-05-MU 213 BIS00LU BIS C-380-06/06-02 154
BIS0055 BIS M-301-001-S115 73 BIS00CR BIS L-405-033-004-05-MU 213 BIS00LW BIS M-402-045-002-07-S4 92
BIS0056 BIS M-301-003-S115 73 BIS00CT BIS L-405-037-001-05-MU 211 BIS00LY BIS M-699-052-050-03-ST11 119
BIS0057 BIS M-302-001-S115 63 BIS00CU BIS L-405-037-002-05-MU 212 BIS00LZ BIS M-350-001-S115 95
BIS0059 BIS M-302-003-S115 63 BIS00CW BIS L-405-037-003-05-MU 213 BIS00M1 BIS M-402-045-004-07-S4 93
BIS005A BIS M-304-001-S115 65 BIS00CY BIS L-405-037-004-05-MU 213 BIS00M2 BIS M-152-03/A 53
BIS005C BIS M-351-001-S115 75 BIS00CZ BIS L-409-045-001-07-S4 216 BIS00M6 BIS M-341-001-S115 77
BIS005F BIS S-301-S115 241 BIS00E0 BIS L-409-045-002-07-S4 217 BIS00M7 BIS U-6020-053-104-00-ST26 29
BIS005R BIS S-302-S115 241 BIS00E1 BIS L-409-045-003-07-S4 217 BIS00M8 BIS M-140-02/A-M8 57
BIS005T BIS S-303-S115 241 BIS00E2 BIS L-409-045-004-07-S4 217 BIS00M9 BIS M-140-02/A-M6 57
BIS005Z BIS C-300-PU1-05 140 BIS00E3 BIS L-6000-007-050-00-ST15 221 BIS00N1 BIS M-6000-007-050-00-ST15 109
BIS0066 BIS C-305-PU1-01 142 BIS00E6 BIS L-6002-019-050-03-ST11 223 BIS00N6 BIS M-340-001-S115 95
BIS0067 BIS C-305-PU1-05 142 BIS00E7 BIS L-6003-025-050-03-ST12 225 BIS00N7 BIS C-6005-027-650-05-ST4 161
BIS0068 BIS C-305-PU1-10 142 BIS00E8 BIS L-6020-007-050-00-ST15 221 BIS00N8 BIS C-380-05/06-05 155
BIS006F BIS C-306-PU1-05 140 BIS00EC BIS L-6022-019-050-03-ST14 223 BIS00N9 BIS C-380-06/06-05 154
BIS006Y BIS C-315/05-S4 148 BIS00EE BIS L-6023-025-050-03-ST13 225 BIS00NA BIS U-6027-054-104-06-ST27 29
BIS006Z BIS C-315/10-S4 148 BIS00EF BIS L-6026-034-050-06-ST19 226 BIS00NK BIS M-305-001-S115 87
BIS0075 BIS C-318-PU1-05 151 BIS00EH BIS L-6027-039-050-06-ST19 227 BIS00NL BIS U-100-01/CA 24
BIS0076 BIS VM-352-001-S4 91 BIS00EJ BIS M-400-007-001-00-S115 69 BIS00NU BIS M-143-02/A-M6 55
BIS0077 BIS C-319-PU1-01 143 BIS00EK BIS M-400-007-002-00-S115 71 BIS00NW BIS M-143-02/A-M8 55
BIS0078 BIS C-319-PU1-05 143 BIS00EM BIS M-401-007-001-00-S115 79 BIS00NY BIS M-352-001-S115 86
BIS0079 BIS C-319-PU1-10 143 BIS00EN BIS M-402-007-002-00-S115 92 BIS00NZ BIS M-191-02/A 53
BIS007A BIS C-319/05-S4 146 BIS00EP BIS M-407-039-003-06-S115 115 BIS00P0 BIS U-301-C0-TNCB 30
BIS007C BIS C-319/10-S4 146 BIS00ER BIS M-451-007-001-00-S115 81 BIS00P1 BIS M-154-03/A 53
BIS007J BIS C-323/01-S4 147 BIS00EW BIS M-6002-019-050-03-ST11 111 BIS00P2 BIS M-307-001-S115 87
BIS007K BIS C-323/05-S4 147 BIS00EY BIS M-6003-025-050-03-ST12 113 BIS00P3 BIS M-153-02/A 59
BIS007L BIS C-323/10-S4 147 BIS00F0 BIS M-6022-019-050-03-ST14 111 BIS00P5 BIS C-300-PU1-01 140
BIS007M BIS C-324/05-S4 149 BIS00F1 BIS M-6023-025-050-03-ST13 113 BIS00P6 BIS C-300-PU1-10 140
BIS007N BIS C-324/10-S4 149 BIS00F2 BIS M-6026-034-050-06-ST19 114 BIS00P9 BIS C-302-PU1-10 141
BIS007P BIS C-325/01-S4 146 BIS00F3 BIS S-6002-019-050-03-ST11 243 BIS00PA BIS C-302-PU1-05 141
BIS007R BIS C-325/05-S4 146 BIS00F4 BIS S-6003-025-050-03-ST12 245 BIS00PC BIS C-306-PU1-01 140
BIS007T BIS C-325/10-S4 146 BIS00F5 BIS S-6022-019-050-03-ST14 243 BIS00PE BIS C-306-PU1-10 140
BIS007Y BIS C-326-PU1-05 143 BIS00F6 BIS S-6023-025-050-03-ST13 245 BIS00PF BIS C-310-PU1-01 145
BIS007Z BIS C-326-PU1-10 143 BIS00F7 BIS S-6026-034-050-06-ST19 246 BIS00PH BIS C-310-PU1-05 145
BIS0080 BIS C-327-05 150 BIS00F8 BIS S-6027-039-050-06-ST19 247 BIS00PJ BIS C-310-PU1-10 145
BIS0081 BIS C-328/05-S49 151 BIS00H6 BIS C-60R-001-08P-PU-05 156 BIS00PK BIS C-315-PU1-01 144
BIS0086 BIS C-350-00.3 153 BIS00H7 BIS C-60R-001-08P-PU-10 156 BIS00PL BIS C-315-PU1-05 144
BIS008E BIS C-355/05-S92 153 BIS00H8 BIS C-60R-001-08P-PU-20 156 BIS00PM BIS C-315-PU1-10 144
BIS008P BIS M-304-003-S115 65 BIS00HC BIS C-60R-002-08P-PU-05 156 BIS00PN BIS C-351-PU1-05 151
BIS008U BIS C-600-007-650-00-KL1 158 BIS00HE BIS C-60R-002-08P-PU-10 156 BIS00PP BIS C-351-PU1-10 151
BIS008W BIS C-600-007-650-02-KL1 158 BIS00HH BIS C-60R-003-08P-PU-05 156 BIS00PT BIS M-142-02/A-M6-GY 55
BIS0092 BIS C-600-007-670-00-KL1 159 BIS00HJ BIS C-60R-003-08P-PU-10 156 BIS00PU BIS M-142-02/A-M8-GY 55
BIS0099 BIS C-6002-019-650-03-KL2 162 BIS00HL BIS C-61R-001-08P-PU-05 157 BIS00PZ BIS M-440-039-001-06-ST2 97
BIS009A BIS C-6002-019-650-03-ST11 162 BIS00HM BIS M-688-001 118 BIS00R0 BIS M-450-039-001-06-ST2 97
BIS009F BIS C-6002-019-654-03-ST11 163 BIS00J0 BIS M-6000-007-050-00-ST24 109 BIS00R1 BIS U-6027-060-114-06-ST27 29
BIS009H BIS C-6002-019-655-03-KL2 163 BIS00J1 BIS C-140-11/L-M8 139 BIS00R2 BIS U-6020-059-114-00-ST26 29
BIS009J BIS C-6002-019-655-03-ST11 163 BIS00J2 BIS C-140-05/L-M8 139 BIS00R3 BIS M-341-003-S115 77
BIS009K BIS C-6002-019-670-03-KL2 163 BIS00J3 BIS C-140-11/L-M6 139 BIS00R4 BIS M-144-02/A-M6-GY 57
BIS009L BIS C-6002-028-650-03-KL2 162 BIS00J4 BIS C-140-05/L-M6 139 BIS00R5 BIS M-144-02/A-M8-GY 57
BIS009M BIS C-6002-028-650-03-ST11 162 BIS00JE BIS C-380-05/06-02 155 BIS00RC BIS U-100-02/CA 24
BIS009N BIS C-6003-025-650-03-ST12 166 BIS00JJ BIS C-380-06/06-01 154 BIS00RF BIS VM-300-001-S4 67
BIS009R BIS C-6003-025-655-03-ST12 167 BIS00JM BIS C-380-06/10-02 155 BIS00RN BIS L-306-S115 205
BIS009T BIS C-6003-025-670-03-ST12 167 BIS00JN BIS C-380-06/10-05 155 BIS00RU BIS M-402-007-004-00-S115 93
BIS00AL BIS C-6022-019-050-03-ST10 165 BIS00JP BIS C-380-10/10-01 155 BIS00RZ BIS M-115-03/A-SA2 51
BIS00AM BIS C-6022-019-050-03-ST14 165 BIS00JR BIS C-380-10/10-05 155 BIS00T0 BIS VM-301-001-S4 73
BIS00AP BIS C-6022-028-050-03-ST10 165 BIS00JT BIS L-380-02/BU-PU1-00,15 209 BIS00T1 BIS M-122-02/A-SA2 54
BIS00AR BIS C-6022-028-050-03-ST14 165 BIS00JU BIS L-380-02/BU-PU1-00,5 209 BIS00T2 BIS VM-351-001-S4 75
BIS00AT BIS C-6023-025-050-03-ST13 169 BIS00JW BIS L-380-05/BU-PU1-00,15 209 BIS00T3 BIS V-6102-019-C001 121,
BIS00AU BIS C-6026-034-050-06-ST19 170 BIS00JY BIS L-380-05/BU-PU1-00,5 209 229
BIS00AY BIS C-6027-039-050-06-ST19 171 BIS00JZ BIS L-380-10/BU-PU1-00,5 209 BIS00T7 BIS VM-306-001-S4 89
BIS00AZ BIS C-620-007-050-00-ST2 159 BIS00K1 BIS L-380-ST/10 208 BIS00T8 BIS VM-307-001-S4 89
BIS00C5 BIS L-400-035-001-00-S115 214 BIS00K3 BIS C-6008-048-650-06-ST23 172 BIS00T9 BIS VM-305-001-S4 91
BIS00C6 BIS L-400-035-001-02-S115 214 BIS00K4 BIS C-6028-048-050-06-ST22 173 BIS00TA BIS VM-341-001-S4 77
BIS00C7 BIS L-400-035-002-00-S115 215 BIS00KM BIS M-115-03/A 51 BIS00TC BIS C-60R-002-08P-PU-20 156
BIS00C8 BIS L-400-035-002-02-S115 215 BIS00KU BIS M-351-003-S115 75 BIS00TU BIS C-6028-048-050-06-ST28 173
BIS00C9 BIS L-400-035-003-00-S115 215 BIS00KW BIS C-620-007-050-02-ST2 159 BIS00TW BIS M-6028-048-050-06-ST28 117
BIS00CA BIS L-400-035-003-02-S115 215 BIS00KZ BIS M-6028-048-050-06-ST22 117 BIS00TY BIS U-301-C1-TNCB 31
BIS00CC BIS L-400-035-004-00-S115 215 BIS00L4 BIS C-318-PU1-10 151 BIS00TZ BIS U-302-C0-TNCB 31
BIS00CH BIS L-400-043-001-02-S115 218 BIS00L7 BIS M-6008-048-050-06-ST23 117 BIS00U0 BIS U-302-C1-TNCB 31
BIS00CJ BIS L-400-043-002-02-S115 219 BIS00LC BIS M-107-03/L-H200 61 BIS00U6 BIS VL-301-001-S4 199
BIS00CK BIS L-400-043-003-02-S115 219 BIS00LH BIS M-400-045-001-07-S4 69 BIS00U9 BIS V-6110-063-C002 121,
BIS00CL BIS L-400-043-004-02-S115 219 BIS00LJ BIS M-400-045-002-07-S4 71 229
BIS00CM BIS L-405-033-001-05-MU 211 BIS00LK BIS M-401-045-001-07-S4 79 BIS00UC BIS M-116-03/A 43

■ www.balluff.com 389
Alphanumeric Directory
Sorted by ordering code

Ordering Part number Page Ordering Part number Page Ordering Part number Page
code code code
BIS00UE BIS M-116-08/A 43 BNI005E BNI TCP-951-000-E028 311 SET014T BAV BP-PH-00092-02 269
BIS00UF BIS VL-302-001-S4 203 BNI005H BNI PNT-508-105-Z015 300 SET014U BAV BP-PH-00092-03 269
BIS00UH BIS VL-304-001-S4 204 BNI005R BNI PBS-502-101-Z001 301 SET014W BAV BP-PH-00092-04 269
BIS00UJ BIS VL-306-001-S4 205 BNI0067 BNI TCP-952-000-E029 311 SET014Y BAV BP-PH-00092-05 269
BIS00UK BIS VL-350-001-S4 207 BNI006A BNI EIP-508-105-Z015 300 SET014Z BAV BP-PH-00092-06 269
BIS00UL BIS VL-300-001-S4 197 SET0150 BAV BP-PH-00092-07 269
BIS00UY BIS M-402-045-005-07-S4-SA1 93 BVS
BIS00W1 BIS M-410-067-001-04-S92 83 BVS0001 BVS ID-3-001-E 261 Sonstiges
BIS00W2 BIS M-410-068-001-00-S115 83 BVS0003 BVS OI-3-001-E 263 125997 Akku-BIS C-81. 2,4V 1500 MAH 249
BIS00W3 BIS M-410-068-001-02-S115 83 BVS0004 BVS OI-3-002-E 263 BIS C-133-11/L 139
BIS00W4 BIS M-410-068-001-09-S72 83 BVS0005 BVS OI-3-003-E 263 BIS C-319/01-S4 146
BIS00W5 BIS M-411-067-001-04-S92 85 BVS0006 BVS OI-3-004-E 263 BIS C-327-01 150
BIS00W6 BIS M-411-068-001-00-S115 85 BVS000C BVS OI-3-006-E 263 BIS C-327-10 150
BIS00W7 BIS M-411-068-001-02-S115 85 BVS000E BVS OI-3-005-E 263 BIS C-328/01-S49 151
BIS00W8 BIS M-411-068-001-09-S72 85 BVS000J BVS OI-3-051-E 265 BIS C-328/10-S49 151
BIS00W9 BIS M-136-03/L 51 BVS000K BVS OI-3-053-E 265 BIS C-600-007-654-00-KL1 159
BIS00WC BIS U-102-05/CA-HT 25 BVS000L BVS OI-3-055-E 265 BIS C-6003-025-654-03-ST12 167
BIS00WE BIS U-102-05/CA 25 BVS000N BVS OI-3-054-E 265 BIS C-60R-003-08P-PU-20 156
BIS00WF BIS U-101-04/CA-HT 25 BVS000P BVS OI-3-052-E 265 BIS C-870-1-008-X-002 175
BIS00WH BIS U-101-04/CA 25 BVS000R BVS OI-3-056-E 265 BIS C-870-1-008-X-003 175
BIS00WJ BIS M-500-PVC-07-A01/02 100 BVS000T BVS ID-3-003-E 261 BIS C-870-1-008-X-005 175
BIS00WK BIS M-373-000-A01 107 BVS000W BVS OI-3-057-E 265 BIS C-871-1-008-X-001 175
BIS00WL BIS M-372-000-A01 105 BVS000Y BVS ID-3-007-E 261 BIS C-871-1-008-X-002 175
BIS00WM BIS M-371-000-A01 103 BVS0012 BVS OI-3-103-E 263 BIS C-871-1-008-X-003 175
BIS00WN BIS M-370-000-A02 101 BVS0013 BVS OI-3-105-E 263 BIS C-871-1-008-X-004 175
BIS00Y1 BIS M-136-03/L-HAT 61 BVS0014 BVS OI-3-101-E 263 BIS C-871-1-008-X-005 175
BIS00Y2 BIS M-135-07/L-HAT 61 BVS0015 BVS OI-3-151-E 265 BIS C-873-1-008-X-001 175
BIS00Y3 BIS M-135-07/L 49 BVS0016 BVS OI-3-155-E 265 BIS C-873-1-008-X-002 175
BIS00Y4 BIS M-135-03/L-HAT 61 BVS0017 BVS OI-3-153-E 265 BIS C-873-1-008-X-003 175
BIS00Y5 BIS M-135-03/L 49 BVS0019 BVS ID-3-101-E 261 BIS C-873-1-008-X-005 175
BIS00Y6 BIS M-135-02/L 49 BVS001A BVS ID-3-103-E 261 BIS L-870-1-008-X-002 233
BIS00Y7 BIS M-134-10/L-HAT 60 BVS001C BVS ID-3-105-E 261 BIS L-870-1-008-X-003 233
BIS00Y9 BIS M-133-02/A 45 BVS001F BVS UR-3-105-E 267 BIS L-870-1-008-X-005 233
BIS00YA BIS M-132-10/L-HAT 60 BVS001H BVS UR-3-101-E 267 BIS L-871-1-008-X-001 233
BIS00YC BIS M-132-10/L 45 BVS001J BVS UR-3-103-E 267 BIS L-871-1-008-X-002 233
BIS00YE BIS M-132-03/L-HAT 60 BVS001L BVS UR-3-005-E 267 BIS L-871-1-008-X-003 233
BIS00YF BIS M-132-03/L 44 BVS001M BVS UR-3-001-E 267 BIS L-871-1-008-X-004 233
BIS00YK BIS M-130-07/L 43 BVS001N BVS UR-3-003-E 267 BIS L-871-1-008-X-005 233
BIS00YL BIS M-130-03/L 43 BVS001P BVS UR-3-007-E 267 BIS L-873-1-008-X-002 233
BIS00YY BIS U-626-069-111-06-ST32 27 BVS001R BVS ID-3-005-E 261 BIS L-873-1-008-X-003 233
BIS00Z0 BIS U-626-069-101-06-ST32 27 BIS L-873-1-008-X-005 233
BIS00Z2 BIS U-620-068-111-00-ST29 27 FHW BIS M-870-1-008-X-001 125
BIS00Z4 BIS U-620-068-101-00-ST29 27 FHW0003 11023834 124, BIS M-870-1-008-X-002 125
BIS00Z6 BIS U-620-067-111-04-ST30 27 174, BIS M-870-1-008-X-003 125
BIS00Z8 BIS U-620-067-101-04-ST30 27 232, BIS M-870-1-008-X-005 125
BIS00ZA BIS M-626-069-A01-06-ST32 99 315 BIS M-871-1-008-X-001 125
BIS00ZH BIS M-620-068-A01-00-ST29 99 FHW0004 11023836 124, BIS M-871-1-008-X-002 125
BIS00ZK BIS M-620-067-A01-04-ST30 99 174, BIS M-871-1-008-X-003 125
BIS00ZU BIS U-6028-048-104-06-ST28 29 232, BIS M-871-1-008-X-004 125
BIS00ZW BIS U-6028-048-114-06-ST28 29 315 BIS M-871-1-008-X-005 125
BIS00ZY BIS L-103-05/L-ZC1 235 BIS M-873-1-008-X-002 125
BIS0102 BIS M-401-072-001-07-S4 79 SET BIS M-873-1-008-X-005 125
BIS0103 BIS M-451-072-001-07-S4 81 SET0121 BAV BP-PH-00068-01 269 710691 MONTAGESCHLUESSEL BIS CODETRAEGER 135
BIS0104 BIS M-400-072-002-07-S4 71 SET0122 BAV BP-PH-00069-01 269
BIS0105 BIS M-402-072-002-07-S4 92 SET0123 BAV BP-PH-00070-01 269
BIS0106 BIS M-402-072-004-07-S4 93 SET0124 BAV BP-PH-00071-01 269
BIS0108 BIS M-400-072-001-07-S4 69 SET0125 BAV BP-PH-00073-01 269
BIS010P BIS V-6111-073-C003 121, SET0126 BAV BP-PH-00074-01 269
229 SET0127 BAV BP-PH-00075-01 269
BIS010R BIS M-153-20/A 59 SET0128 BAV BP-PH-00076-01 269
BIS0111 BIS M-108-20/A 50 SET0129 BAV BP-PH-00077-01 269
BIS0112 BIS M-156-20/A 59 SET012A BAV BP-PH-00078-01 269
BIS0117 BIS M-155-20/A 59 SET012C BAV BP-PH-00079-01 269
BIS0119 BIS M-142-20/A-M8-GY 55 SET012J BAV BP-PH-00017-01 269
SET012K BAV BP-PH-00018-01 269
BNI SET012L BAV BP-PH-00019-01 269
BNI000F BNI EIP-950-000-Z009 310 SET012M BAV BP-PH-00020-01 269
BNI0030 BNI PBS-504-001-K008 301 SET012N BAV BP-PH-00021-01 269
BNI003K BNI PBS-502-001-Z001 300 SET012P BAV BP-PH-00022-01 269
BNI003P BNI PBS-507-001-Z011 301 SET012R BAV BP-PH-00023-01 269
BNI0040 BNI CCL-502-100-Z001 301 SET012T BAV BP-PH-00024-01 269
BNI004A BNI EIP-502-105-Z015 300 SET012U BAV BP-PH-00025-01 269
BNI004U BNI PNT-502-105-Z015 300 SET012W BAV BP-PH-00026-01 269
BNI005A BNI DNT-502-100-Z001 300 SET014R BAV BP-PH-00092-01 269

390
Retrieving Product Information
CAD and electronic diagram formats available
Online

■ All catalog products are available: inductive sensors,


photoelectric sensors, sensors for pneumatic cylinders,
micropulse transducers, industrial RFID systems,
vision sensors BVS, mechanical single and multiple position
switches, industrial networking and connectivity, and so on.
■ sizephics reduced to the essentials
for optimized performance

CAD formats on the Cadenas PARTserver

The benefits to you


■ Faster and more efficient designing
■ Free availability of all Balluff catalog products
■ All common CAD formats
■ Convenient preview in 3D
■ Configurable products

And here is how it works


■ Go to the 3D data at www.balluff.com
■ You are redirected to the Cadenas PARTserver
■ Select a sensor and perform an optional check via 3D preview
■ Add it to the shopping cart
■ Once you have entered your details, the CAD files of your choice
are sent to you by e-mail

EPLAN macros – Electrical project planning made easy


And now users of EPLAN electrical project planning software can
also profit from this free service. On our Web site planners and
designers can download macros for selected Balluff products at no
charge and implement them in their design. These macros include
all the necessary graphics, technical and commercial information for
the electrical design and documentation. Benefit from significant time
and cost savings.

■ www.balluff.com 391
Worldwide sales
Headquarters Canada Greece Kazakhstan
Balluff Canada Inc. S. NAZOS S.A. elcos electric control systems
Germany 2840 Argentia Road, Unit 2 10 KLM Thessalonikis-Kilkis 2A, Molodezhniy Str. 3D
Balluff GmbH Mississauga, Ontario L5N 8G4 P.O. Box 57008 Block O., Offices 318-319
Schurwaldstrasse 9 Phone +1 905 816-1494 Thessaloniki 050061 Almaty
73765 Neuhausen a.d.F. Toll-free 1-800-927-9654 Phone +30 2310 462120 Phone +7 727 3340536
Phone +49 7158 173-0 Fax +1 905 816-1411 Fax +30 2310 474079 Fax +7 727 3340539
Fax +49 7158 5010 balluff.canada@balluff.ca parasxos@nazos.gr info@elcos.kz
balluff@balluff.de
Chile Hong Kong Kuwait
Microtec S/A Sensortech Company Multiline Technical Co.,
Subsidiaries and Salar Ascotan, Parque Enea Pud 1281 No. 43, 18th Street United Arab Emirates
Representatives Santiago Hong Lok Yuen,
Tel. + 56 2 25954661 Tai Po, NT Latvia and Estonia
Argentina soledadrozas@micro.cl Phone +852 26510188 SIA Interautomatika
Balluff Argentina S.R.L. Fax +852 26510388 Brīvības g. 410
Echeverría 1050, 1st UF 2 China sensortech@netvigator.com 1024 Rīga
1604 Florida Oeste, Balluff (Shanghai) Trading Co., Ltd. Phone +371 67522010
Buenos Aires 8F, Building A, Yunding International Hungary Fax +371 67522007
Phone +54 11 4730-4544 Commercial Plaza, Balluff Elektronika Kft. info@interautomatika.lv
Fax +54 11 4730-3908 No. 800 Chengshan Rd, Pápai út. 55.
Pudong, Shanghai, 200125 8200 Veszprém Lithuania
Australia Phone +86 21 5089 9970 Phone +36 88 421808 UAB Interautomatika
Balluff-Leuze Pty. Ltd. Fax +86 21 5089 9975 Fax +36 88 423439 Kęstučio 47
12 Burton Court info@balluff.com.cn saleshu@balluff.hu 08127 Vilnius
Bayswater VIC 3153 Phone +370 5 2607810
Phone +61 397 204100 Columbia Iceland Fax +370 5 2411464
Fax +61 397 382677 Balluff Controles Smith & Norland andrius@interautomatika.lt
sales@balluff.com.au Elétricos Ltda., Nóatúni 4
Brazil 105 Reykjavík Malaysia
Austria Phone +354 520 3000 Profacto Solution & Service Sdn. Bhd.
Balluff GmbH Croatia Fax +354 520 3011 No.30A, Jalan Anggerik Mokara G31/G,
Industriestraße B16 HSTEC d.d. olaf@sminor.is Kota Kemuning, 40460 Shah Alam, Selangor
2345 Brunn am Gebirge Zagrebacka 100 Phone +60 3 51 21 85 28
Phone +43 2236 32521-0 23000 Zadar India Fax +60 3 51 21 85 27
Fax +43 2236 32521-46 Phone +385 23 205-405 Balluff India ckkkyong@streamyx.com
sensor@balluff.at Fax +385 23 205-406 405 Raikar Chambers
info@hstec.hr Deonar Village Road, Team Automation Systems (M) Sdn. Bhd.
Bahrain Govandi, Mumbai 400088 2A, Jalan MP17, Taman Merdeka Permai,
Multiline Technical Co., Czech Republic Phone +91 22 25568097 Batu Berendam, 75250 Melaka
United Arab Emirates Balluff CZ, s.r.o Fax +91 22 25560871 Phone +60 6 3366223
Pelušková 1400 balluff@balluff.co.in Fax +60 6 3368223
Belarus 198 00 Praha 9 – Kyje sales@teamtas.com.my
Automaticacentre OOO Phone +420 281 000 666 Indonesia
Nezavisimosti Av. 185, Fax +420 281 940066 PT. GUNADAYA SOLUTECH Team Automation Systems (M) Sdn. Bhd.
Block 19, Office 3 obchod@balluff.cz Industrial Electrical Products No. 94-B, Jalan Raja Uda
220125 Minsk Ruko Golden Boulevard, Block G, No. 18 12300 Butterworth, Penang
Phone +375 17 2838940 Denmark BSD City, Serpong Phone +60 4 3102888
Fax +375 17 2181798 Balluff ApS 15322 Banten Fax +60 4 3102889
info@automatica.by Åbogade 15 Phone +62 21 53160995 sales-pg@teamtas.com.my
8200 Århus N Fax +62 21 53160994
Belgium Phone +45 70 234929 info@gunadaya.com Mexico
Balluff bvba Fax +45 70 234930 Balluff de México S.A. de C.V.
Researchpark Haasrode 1820 info.dk@balluff.dk Israel Anillo Vial II Fray Junípero Serra No. 4416
Interleuvenlaan 62, Ancitech Ltd. Colonia La Vista Residencial, CP 76232
3001 Leuven Egypt 19, Hamashbir St. Delegación Epigmenio González
Phone +32 16 397800 EGEC Industrial Zone Holon Queretaro, Qro.
Fax +32 16 397809 24 St., 302 Taksym El Kodah-smouha, 58853 Holon Phone +52 442 2124882
info.be@balluff.be First Floor, Department 1 Phone +972 3 5568351 Fax +52 442 2140536
Alexandria Fax +972 3 5569278 balluff.mexico@balluff.com
Brazil Phone +20 3 4299771 tuvia@ancitech.com
Balluff Controles Fax +20 3 4261773 Morocco
Elétricos Ltda. info@egecgroup.com Italy TAK
Rua Francisco Foga, 25 Balluff Automation s.r.l. Ilot 24B, Lot 24A-2
Distrito Industrial Finland Via Morandi 4 Tanger Free Zone
CEP 13280.000 Murri Oy 10095 Grugliasco, Torino 9000 Tanger
Vinhedo – Sao Paulo Koukkukatu 1 Phone +39 11 3150711 Phone +212 06 61464946
Phone +55 19 38769999 15700 Lahti Fax +39 11 3170140 Fax +212 05 39393269
Fax +55 19 38769990 Phone +358 3 8824000 info.italy@balluff.it o.zerhouani@tak.ma
balluff@balluff.com.br Fax +358 3 8824040
myynti@murri.fi Japan Netherlands
Bulgaria Balluff Co., Ltd. Balluff B.V.
BPS AG France Aqua Hakusan Bldg. 9F Europalaan 6a
41, Nedelcho Bonchev St. Balluff SAS 1-13-7 Hakusan, Bunkyo-ku, 5232 BC 's-Hertogenbosch
1528 Sofia 5 Rue des Vieilles Vignes Tokyo 113-0001 Phone +31 73 6579702
Phone +359 2 9609875 Bâtiment A Phone +81 3 3830-0520 Fax +31 73 6579786
Fax +359 2 9609896 77183 Croissy Beaubourg Fax +81 3 3830-0519 info.nl@balluff.nl
bps@bps.bg Phone +33 1 64111990 info.jp@balluff.jp
Fax +33 1 64111991 New Zealand
info.fr@balluff.fr Balluff-Leuze Pty. Ltd.,
Australia

392
Norway Saudi Arabia Spain Ukraine
Primatec as Multiline Technical Co., Balluff S.L. Micronlogistik Ltd.
Lillesandsveien 44 United Arab Emirates Edificio Forum SCV Ul. Promyischlennaya Street 37
4877 Grimstad Planta 5°, Oficina 4° 65031 Odessa
Phone +47 37 258700 Serbia Carretera Sant Cugat a Rubi Phone +380 48 7781278
Fax +47 37 258710 ENEL d.o.o. Km01, 40-50 Fax +380 48 2358760
post@primatec.no Ul. Vasilja Pavlovica 10 08190 Sant Cugat del Vallés info@balluff-ua.com
14000 Valjevo Barcelona
Oman Phone +381 14 291161 Phone +34 93 5441313 United Arab Emirates
Multiline Technical Co., Fax +381 14 244641 Fax +34 93 5441312 Multiline Technical Co.
United Arab Emirates enelvaljevo@gmail.com info.es@balluff.es TCA, behind ADCB Bank
46530 Abu Dhabi
Philippines Singapore Sweden Phone +971 2 6430733
Technorand Sales Corporation Balluff Asia Pte. Ltd. Balluff AB Fax +971 2 6430778
122 McArthur Highway 18 Sin Ming Lane Gamlestadsvägen 2, B19 asif@multilinetech.com
Malabon, Metro Manila #06-41 Midview City, 41502 Göteborg
Phone +632 7245006 Singapore 573960 Phone +46 31 3408630 United Kingdom and Ireland
Fax +632 7245010 Phone +65 62524384 Fax +46 31 3409431 Balluff Ltd.
technorand@gmail.com Fax +65 62529060 info.se@balluff.se 4 Oakwater Avenue
balluff@balluff.com.sg Cheadle Royal Business Park
Poland Switzerland Cheadle, Cheshire SK8 3SR
Balluff Sp. z o.o. Slovakia Balluff Sensortechnik AG Phone +44 161 282-4700
Ul. Muchoborska 16 Balluff Slovakia s.r.o. Riedstrasse 6 Fax +44 161 282-4701
54-424 Wrocław Blagoevova 9 8953 Dietikon sales@balluff.co.uk
Phone +48 71 3384929 85104 Bratislava Phone +41 43 3223240
Fax +48 71 3384930 Phone +421 2 67200062 Fax +41 43 3223241 USA
balluff@balluff.pl Fax +421 2 67200060 sensortechnik@balluff.ch Balluff Inc.
info@balluff.sk 8125 Holton Drive
Portugal Taiwan Florence, KY 41042-0937
LA2P Lda. Slovenia Canaan Electric Corp. Phone +1 859 727-2200,
Rua Teofilo Braga, 156 A Senzorji SB d.o.o., 6F-5, No. 63 Sec. 2 Toll-free 1-800-543-8390
Escrit. F – Edificio S. Domingos Proizvodnja, Chang An East Road Fax +1 859 727-4823
Cabeco Do Mouro trgovina in storitve d.o.o. 10455 Taipei balluff@balluff.com
2785-122 S. Domingos De Rana Livadna ulica 1 Phone +886 22 5082331
Phone +351 21 4447070 2204 Miklavž na Dravskem polju Fax +886 22 5084744 Venezuela
Fax +351 21 4447075 Phone +386 2 6290300 sales@canaan-elec.com.tw Balluff Controles
la2p@la2p.pt Fax +386 2 6290302 Elétricos Ltda.,
senzorji.sb@siol.net Thailand Brazil
Qatar Compomax Co. Ltd.
Multiline Technical Co., South Africa 16 Soi Ekamai 4, Vietnam
United Arab Emirates PAL Distributors CC Sukhumvit 63 Rd. Anh Nghi Son Service Trading Co., Ltd.
291A Pine Avenue, Ferndale Prakanongnua, Vadhana, D3 KDC Mieu Noi Dinh Tien Hoang St.,
Romania Randburg, Gauteng Bangkok 10110 W3, Binh Thanh Dist.,
Balluff Automation SRL Phone +27 11 7814381 Phone +66 2 7269595 Ho Chi Minh City
Strada Industriilor Nr. 56., Fax +27 11 7818166 Fax +66 2 7269800 +84 8 35170401
Bloc 1, Etaj 1 pal@polka.co.za info@compomax.co.th +84 8 35170403
032901 Bucuresti Sector 3 ans.vina@gmail.com
Phone +40 374 926252 South Korea Turkey
Fax +40 374 097 423 Mahani Electric Co. Ltd. Balluff Sensor Otomasyon
office@balluff.com.ro 792-7 Yeoksam-Dong Sanayi Ve Ticaret Ltd. Sti.
Gangnam-Gu, Seoul Perpa Ticaret Is Merkezi
Russia Post code: 135-080 A Blok, Kat 1-2-3
Balluff OOO Phone +82 2 21943300 No: 0013-0014
M. Kaluzhskaya Street 15 Fax +82 2 21943397 34381 Okmeydani/Istanbul
Building 17, Office 500 yskim@hanmec.co.kr Phone +90 212 3200411
119071 Moscow Fax +90 212 3200416
Phone +7 495 78071-94 balluff@balluff.com.tr
Fax +7 495 78071-97
balluff@balluff.ru

■ www.balluff.com 393
Customized Services
According to your specifications. In the best quality.

Balluff offers highly efficient sensor technology with high-perfor-


mance mini sensors and compact connection technology. And
more. Because with our extensive services, you can obtain support
direct from the manufacturer: from the design and planning of your
projects, to testing and setup on-site, to training and support. Over
the entire life cycle of our products.

This creates greater planning security and provides faster com-


missioning and an earlier start of production. This leads to higher You can find more
productivity and more cost-effectiveness. And this relieves you of ad- information in our Services
ditional stress in your everyday work, giving you more time to focus brochure or send us an
on your core business. e-mail: tsm.de@balluff.com

Application advice Real-world examples:


through our TecSupport: ■ Selection of the correct identification procedure for an assembly line
Discuss your technical require- ■ IO-Link concept as a cost-effective alternative to conventional wiring
ments. And take advantage of ■ System consulting for radio frequency identification (RFID): identification of large steel pipes in adver-
our expertise. se environments
■ Recognizing multiple containers on a pallet in goods receiving

Commissioning: Order Real-world examples:


expert knowledge. And ■ Setting up an optical checkpoint with the vision sensor BVS
benefit from a ■ Consulting and support during the programming of RFID systems BIS
quick start of production. ■ Installation and commissioning of a color detection application with the color sensor BFS
Fully customized products: Real-world examples:
Order individual ■ Extending the housing of a high-pressure resistant inductive sensor BHS
versions according to your ■ Extra threads for the housing cover of a micropulse transducer BTL
requirements: from preassembly ■ Customer-specific holder for an RFID data carrier
to engineering services. And ■ Adaptation of the characteristics for analog sensors BAW
take advantage of the optimum.

Workshops: Make use ■ Professional sensor use: Select operating principles,


of well-founded manufacturer install sensors professionally and ensure the reliable operation of your application.
expertise. ■ Position and Distance Measurement: This is how you perform precise and wear-free
And benefit from application measurements.
security. ■ RFID: The right data at the right time at the right place.
■ Vision sensor: Using an image processing sensor, ensure manufacturing quality in three steps.
■ Vision sensor identification: Reliably identify data matrix codes with an image-processing sensor.
■ Industrial networking with IO-Link: Manage signals intelligently and cost-effectively.

The right solutions

Less time required

High application security

Significant cost reduction

■ www.balluff.com 395
Custom-programmed
RFID data carriers
Use data carriers written according to your specifications.
And accelerate your production.

In assembly lines where the application is read-only or pallets will To do so, simply indicate your data to us, tell us your desired
only need to be identified, it is often sufficient to write a consecutive format and the section of the data carrier to which it should
number or a special code on the data carrier. be saved. Use a service that brings advantages to your time
management and guarantees quick commissioning.
Let us take over this programming. And order increased comfort.
By means of finished, written LF, HF or UHF data carriers from the
factory which are ready for use immediately.

The benefits to you


■ Cost-effective – no need to maintain separate hardware for writing
■ Time-saving – programming write routines can be omitted entirely
■ Reorder availability – reorder a data carrier with the same programming

396
■ www.balluff.com 397
Tool identification
with Industrial RFID
Identify tools with Industrial RFID.
And guarantee product quality.

Tool identification with Industrial RFID means incorrect assign- Capable of integration into all commonly used machine controls, our
ments or missing tools are a thing of the past. Our systems provide Industrial RFID systems ensure flexible and reliable communication in
complete tool data with extreme reliability and guarantee assured tool management. Absolutely without contact and maintenance-free.
operation as well as increased productivity of the equipment. Tools are always accompanied by their individual data so they can
be optimally used and managed.

The benefits to you


■ Service life control outside of the machine as well
■ Quality assurance through error prevention
■ Electronic data transmission and paperless tool information
■ Optimal tool utilization
■ Reduce set-up time through quick and precise tool identification

The system
Balluff Industrial RFID stands for flexible, secure, contactless
communication. The systems are entirely tolerant of environmental
influences on account of their inductive operating principle.
Therefore, they are excellently suited for use in harsh industrial
environments such as the machine tool. Our systems therefore
provide complete tool data robustly and reliably and ensure
reliable identification. Balluff Tool ID supports process reliability.

■ www.balluff.com 399
TecSupport –
Your added value for
planning and commissioning
We offer ... We support you during the project
■ Decision help for the correct product selection implementation, commissioning and integration
■ Complex product and application support ■ Would you like to monitor and track production processes?
■ Integration support ■ Would you like to identify, control, monitor and optimize objects?
■ Customer-specific product and commissioning training ■ Would you like to optimize and simplify your system wiring?
■ Intensive technical support during the entire phase of the project
■ Assumption of time-consuming project work We provide you with specific support
for Balluff system components
■ Vision sensors BVS for optical identification
We are happy to help! ■ Industrial networking and connectivity for wiring and networking
Phone +49 7158 173-401 ■ IO-Link – network technology for reliable data transfer
+49 7158 173-727 and greater efficiency
E-mail TecSupport@balluff.de ■ Industrial identification – RFID for transparency in material flow

Selection
Integration
Instruction
Application
Industrial Identification
Project support
Vision sensors
IO-Link
Industrial Networking and Connectivity
Product
System components
Decision help

400
BIS Application Specification
Company

Address

Contact

Phone

Salesperson

What is the application?

Description

How many read/write stations? How many read and/or write operations per day and tags occur?

Read

Write What will be the cable distance between PLC and processor?

How much/what type of information


is going to be stored on the data carrier?
What type of PLC or PC?

What are the read/write speeds required in the application?


What will the data carrier be mounted in/on (material etc.)?

Non-metal Aluminum Steel

Will the line be moving while reading or writing?


(If moving, what will max velocity be?) What will the read/write head be mounted to (material etc.)?

m/min Non-metal Aluminum Steel

What will the sensing distance be? What will be the method of communication and protocol?

mm RS232 RS422/RS485 Profibus

Devicenet IO-Link easy-loop®


What will the operating temperature range be?
Profibus Ethernet/IP EtherCAT
°C
Ethernet TCP/IP

■ www.balluff.com 401
BIS V –
The new generation
for more efficiency

402
SENSOR
SOLUTIONS AND
SYSTEMS
For all areas of the automation industry
As a global player, we stand for comprehensive system expertise, continuous innovation,
the highest quality and the greatest reliability. Balluff means technological variety
and first-class service. Our 2450 worldwide employees are working to ensure this.

Industrial
Systems Networking and Industrial
and Service Connectivity Identification

Linear Position
Object Sensing and
Detection Measurement

Condition
Monitoring,
Fluid Sensors Accessories

Phone +49 7158 173-0


www.balluff.com
Systems and Service

Industrial Networking and Connectivity

Industrial Identification

Object Detection

Linear Position Sensing and Measurement

Condition Monitoring and Fluid Sensors

Accessories

Headquarters
Balluff GmbH
Schurwaldstrasse 9
73765 Neuhausen a.d.F.
Germany
Phone +49 7158 173-0
Fax +49 7158 5010
balluff@balluff.de

Doc. no. 897840/Mat. no. 233273 EN


G13; Subject to modification.
www.balluff.com