DA AU Smart Distribution

Automation System

INGEPACTM DA AU covers a wide range of applications making it possible to use one single
device to fulfil every automation, protection, measurement and remote control requirements, for
RMUs and overhead applications (LBS) in the secondary grid.

INGEPACTM DA AU is a modular solution being possible to customize each device for different
size substations, from one to several switchgear sets, by defining the number of binary inputs and
Software outputs, analogue inputs from transducers, and current and voltage from instrument transformers
All the equipment in the INGEPACTM family or sensors.
can be accessed using powerful software
tools developed by Ingeteam and which run
INGEPACTM DA AU lets choose different mechanical solutions (compact, front panel, DIN
on Windows®.
The application software is specifically rail) and front interfaces (pushbuttons, LED, etc.), offering the optimal configuration for each
designed for simple and user-friendly access requirement.
to the equipment.

EFS

V
DI / DO / AI DI / DO / AI DI / DO / AI
89 89 52
27

Automat.

P, Q,
cosj
4

4 67
4

FPI

Automation, monitoring and Alarm for excessive number of Communications Local Interface
protection functions trips 2 Ethernet ports RJ45 or LC FO Keys for Local/Remote, Automatic/
Real time monitoring of the Command failure and 1 serial RS232/RS485, GFO Manual and switch operation
substation’s signals Opening and closure command or PFO LED indications
Local and remote control for all (pulsed and latched) Ethernet server protocols:
the feeders of the substation IEC60870-5-104, IEC61850, Web Server
Voltage detection Data Acquisition Functions DNP3 Monitoring, setting and
Directional fault passage Event log Slave serial protocols: IEC60870- configuration and firmware update
indication Oscillography 5-101, IEC60870-5-103, Other functions
Load transfer By feeder: phase and neutral PROCOME User logic
Automatic fault isolation current, voltage, active, reactive Master serial protocol: Modbus Power supply monitoring
Overcurrent protection and apparent power, power factor, RTU (for some models)
frequency
Breaker Monitoring Digital inputs and outputs Synchronisation
Opening, closure, kl2 counters Analogue inputs from transducer SNTP, Irig-B

www.ingeteam.com
powergridautomation@ingeteam.com
Overview INGEPAC
Electromagnetic Main features
and insulation
∙ Measurements of conducted ∙ Control in one single device of several switchgear feeders

The technical data in this catalogue is subject to change without prior notice. FY41IPTT01_E/0918
radio electric disturbances EN 55022
∙ Measurements of radiated
∙ Up to 4 slots for plug-in modules (binary inputs, outputs or analogue inputs)
disturbance field strength EN 55022 ∙ Some models include gateway function from Modbus RTU, in order to integrate devices suppor-
∙ Electrostatic discharges immunity IEC 61000-4-2 ting this protocol in the Smart Grid
∙ Radio frequency electromagnetic ∙ Built-in web server for remote access through a commercial browser. This access allows real time
fields immunity IEC 61000-4-3
monitoring and operation, settings change and log files download
∙ Electrical fast transients
immunity IEC 61000-4-4 ∙ User logic
∙ Surge immunity IEC 61000-4-5
∙ Programmable LEDs
∙ Conducted disturbances induced
∙ Voltage measurement from sensors or from conventional measurement transformers
by radio frequency fields ∙ Serial and Ethernet communication
immunity IEC 61000-4-6
∙ Real-time switchgear monitoring, log and statistical metering
∙ Power frequency magnetic
fields immunity IEC 61000-4-8 ∙ Oscillographic log
∙ Pulsed magnetic fields immunity IEC 61000-4-9 ∙ Multiple setting groups allowing to adapt settings to grid conditions changes instantaneously
∙ Damped oscillatory magnetic ∙ SNTP and IRIG-B synchronization
fields immunity IEC 61000-4-10 ∙ Power supply monitoring
∙ DC power voltage ripple immunity IEC 61000-4-17 ∙ Conformal coating for special environments
∙ Damped oscillatory wave
immunity IEC 61000-4-18
∙ DC power voltage dips,
interruptions and variations Options
immunity IEC 61000-4-29
∙ Low frequency signals immunity IEC 60255-22-7
∙ Operating voltages 24, 48, 125, 220 Vdc
∙ Insulation resistance
measurements IEC 60255-5 ∙ Modules
∙ Impulse voltage IEC 60255-5 CPU with 8 BI + 5 BO
∙ Dielectric IEC 60255-5 15 BI + 8 BO
24 BI + 16 BO
Environmental 3 V + 4 I + 1 AI +13 BI
∙ Cold IEC 60068-2-1 8 I +13 BI
∙ Dry heat IEC 60068-2-2 8 AI + 15 BI
∙ Change of temperature IEC 60068-2-14 4 V + 4 I + 13 BI
∙ Damp heat, steady state IEC 60068-2-78 4 V + 4 I + 4 BI + 4 BO
∙ Degree of protection IP42D ∙ Voltage inputs from sensor (resistive or capacitive divider) or instrument transformer
(front) IEC 60529
∙ High Speed output contacts
Mechanical
∙ Vibration (sinusoidal) IEC 60255-21-1
Applications
∙ Shock and bump IEC 60255-21-2
∙ Seismic IEC 60255-21-3
∙ Vibration (random) IEC 60068-2-64
∙ Ring Main Units and compact transformer substations automation
∙ Overhead distribution automation (LBS, etc.)
∙ Switchgear control
∙ RTU for small substations or power plants

www.ingeteam.com