PROTECTIVE COATING SYSTEM

System: A-5
SERVICE: Steel - Moderate to Severe Exposure (Nonimmersion)
Surface Preparation: Shop: SSPC-SP6 and profile depth 1.5 to 2.5 mils (38 to 63 microns).
Field: SSPC-SP2/3. Clean and dry.
First Coat: High solids polyamine or polyamide epoxy with minimum 67% solids by
volume. Apply at 5.0 to 7.0 mils (125 to 175 microns) dry film thickness.
Second Coat: High solids aliphatic acrylic polyurethane gloss enamel with minimum
52% solids by volume. Apply at 3.0 to 5.0 mils (75 to 125 microns)
film thickness.
System Total: Minimum 8.0 mils (200 microns) dry film thickness.
Volatile Organic Content: Maximum 2.8 lb/gal (340 g/L)
.
COATING
PRODUCT DESIGNATION
MANUFACTURER

FIRST COAT TOUCH UP SECOND COAT


PPG Amerlock 2 or 400 Same as first coat Amercoat 450 H

Carboline Carboguard 890 Same as first coat Carbothane 134 HG

Ceilcote 615 Ceilgard Same as first coat 477 Ceilgard

Devoe - AkzoNobel Devran 224 HS Same as first coat Devthane 389

International Interseal 670 HS Same as first coat Interthane 990 Series

ITW Devcon Futura Flexshield Primer 4484 Same as first coat Flexshield 1000

Keeler & Long Kolormastic II No. 1800 Same as first coat Acrythane KLYC1-Series

Tnemec Epoxoline II-N69 Same as first coat Endura-Shield II, Series 1074

Sherwin-Williams Macropoxy 646 Same as first coat HS Polyurethane


B58-600/B58V600 B65-300 Series

PCS.A5 – 01/2013