Professional Documents
Culture Documents
TS 15130
TS 15130
In addition to the Technical Product Data Sheet and the Safety Data Sheet the following additional test data
are listed for the product:
HEMPADUR 15130
Please note that the measurements given below have been obtained under very controlled laboratory
conditions. On-site measurements may give different results depending on circumstances.
ADHESION/COHESION: (ISO 4624/ASTM D 4541, Saeberg - Pneumatic adhesion tester):
Pull Off Value: 13 MPa (130 kgf/cm2 ).
PRIMER PROPERTIES: HEMPADUR 15130 has very good wetting properties. May be used
on water jetted, shopprimed and mechanically cleaned surfaces.
FLEXIBILITY: (ISO 1519/ASTM D522, Mandrel bend test):
7 % elongation (1 x 110 µm HEMPADUR 15130)
(ASTM D 2370, Tensile Strength and elongation):
2 X 125 µm HEMPADUR 15130 - cured 7 days/23°C
Tensile Strength 22.5 +/-2.6 MPa.
Elongation 2.1 +/-0.6 %.
ABRASION RESISTANCE: (ASTM D 4060, Taber Abraser):
Wheel CS-17, load 1000 grams:
Approx. 240 mg/1000 rotations (Corresponding to a DFT loss of
61 µm/1000 rotations).
WATER UPTAKE: (TNO method ~ DIN 53495: Testing of plastics; determination of
water absorption):
Uptake after 29 days immersion: 1.6 % of dry weight.
WATER VAPOUR PERMEABILITY: (TNO method ~ ISO 2528: Sheet materials, Determination of water
vapour transmission rate):
Water vapour permeability: 0.85 g/m2/24hrs
µ-value: 110,000
(Coating system: 2 X 150 µm HEMPADUR 15130)
RESISTANCE TO AGEING: Coating system:
2 x 150 µm HEMPADUR 15130:
(ISO 6270/ASTM D4585, Condensation chamber):
No blistering or red rust formation and excellent adhesion after 6
months exposure.
(ISO 7253/ASTM B 117, Salt Spray):
No blistering or red rust and 0 mm rust creep from the scribe after
1400 hours exposure.
RESISTANCE TO CATHODIC (BS 3900: part F10):
PROTECTION/DISBONDMENT: No blisters and perfect adhesion after 4 months exposure (-1250
mV) (2 x 175 µm HEMPADUR 15130)
ASTM G 8 - Cathodic Disbondment):
28 days exposure at 23°C (-1500 mV):
8 mm disbondment from the bare spot - perfect adhesion at the
remaining part of the panel. (2 x 150 µm HEMPADUR 15130).
HEMPEL A/S
Products Solutions & Performance
Søren Nyborg Rasmussen
12 January 2005
HEMPEL