AC500 System
AC500 System
customized automation
Subject to alteration
Technical information
Comprehensively customer support
Publication Number: 2CDC125002B0202 Printed in the Federal Republic of Germany (01.05. 5 GVD)
Special seminars and training courses are offered for many ABB
NEW
products and systems, not least covering the automation of machi-
regional consultant.
ABB STOTZ-KONTAKT GmbH ABB Entrelec - Control Division ABB Global Contact Directory
P. O. Box 10 16 80 184, rue Léon Blum
D-69006 Heidelberg F-69100 Villeurbanne / France The ABB Contact Directory (http://www.abb.com/contacts/)
Telephone: ++49 62 21 / 701-0 Telephone: ++33 (0) 4 72 35 35 helps you find local contacts for ABB products in your country.
Telefax: ++49 62 21 / 701-729 Telefax: ++33 (0) 4 72 35 12
Please select the relevant product group from the dropdown
http://www.abb.de/stotz-kontakt http://www.abb.com/lowvoltage
menu to the right or from the page.
The scalable AC500 PLC – flexible,
cost-efficient, future-friendly
Guarantees your safe investment in future
Besides the high performance capabilities of the system regarding handling, reliability and ease of mainte-
Customers’ requirements met to perfection nance, also the long-term availability of the chosen system plays a decisive role: Your safe investment must be
Simple, consistent expandability, flexible when choosing a field bus, and designed for future market trends – ensured in future. With the new AC500, ABB offers a modern high-performance platform which is suitable for
those are some of the demands made on an automation platform, particularly in the mechanical engineering future-oriented automation concepts and open for new trends and market requirements.
sector, but in plant engineering as well. These needs have been worked out in a close dialog with customers
and end-users. And now, they have been realized in the design and high functionality of the new scalable
■ packaging machines
Parallel connection to several buses ■ plastics machines
■ printing presses
The new AC500 consists of different devices that can ■ crane engineering
■ energy optimization
be combined and flexibly expanded to suit the custo- ■ building engineering
■ pumping installations
mer’s individual requirements. It is also possible, for ■ marine engineering
■ wind power installations
instance, to operate several field buses simultaneous- ■ air-conditioning/refrigeration systems
■ tunnel construction
ly in any desired combination with a single control ■ …
2 3
Everything you need for
switching and control
Complete product portfolio
ABB offers a complete range of low-voltage devices from one source: PLC,
Flexible choice of the field bus devices for switching and protection, such as soft starters, contactors, and
Flexibility in the choice of a field bus without needing The FBP is the link to a communicative series of circuit-breakers, up to standard sensors. Many of these ABB components have
to replace any field devices: That’s the basic idea switching and automation components, which can already been integrated into the innovative system concept involved. Examples
behind the field bus plug (FBP). Thanks to this intelli- thus be combined with standard field bus systems here include the UMC22-FBP Universal Motor Controller for effective motor
gent plug connector, field devices „become“ field- in the easiest way. protection and particularly user-friendly motor control, the interactive circuit-
bus-neutral. Thus, changing the field bus (often due breakers Tmax T4, T5, the PSS soft starter and the wireless proximity switch.
to end-user’s wishes), only requires the replacement With the AC500, the FBP product range has been extended by field-bus-neutral
of the plug connector itself – the field devices and I/O modules and a CPU which can also be used as a field bus slave via the FBP.
Circuit-breaker Universal Motor controller Motor Starter AC500 Slave S500 remote I/Os Soft Starters Wireless Proximity
Switches
4 5
Clear advantages thanks to clear
structures The CPU terminal base The FBP interface module
Available in three different versions, enables easy With embedded digital I/Os and a field-bus-neutral
plugging of the CPU and one, two or four communi- interface for connecting the chosen FBP connec-
Flexibility as program cation modules. tor. For decentralized expansion by up to seven I/O
Thanks to its scalability, the AC500 PLC can be adapted to the most different automation tasks: The devices concerned can modules.
be used and combined in a flexible way. The number of different parts to be kept in stock is correspondingly minimized. The I/O modules
The AC500’s system architecture Can be simply plugged onto the terminal units Optional for data logging, downloading and uploa-
The CPUs – for local expansion of the CPU (max. seven modu- ding the user program without a PC or a firmware
are available in the performance classes PM571, les) and decentralized expansion via the FBP inter- update for all devices (CPU, couplers or I/O modu-
PM581 and PM591, can all be programmed in five face. Flexible use thanks to configurable channels. les).
operator keypad, an SD card slot, and two inte- The terminal units
grated serial interfaces. The CPUs can be simply Multi-purpose usage for both digital and analog I/Os,
plugged onto the CPU terminal base. Optionally, for 1, 2 and 3-wire designs. Enable simple prewiring
1 Back-lighted LCD display and keypad
they are also available with integrated Ethernet or without electronics. For 24 V DC and 230 V AC,
2 SD card slot
ARCNET. optionally for spring or screw-type terminals.
3 Plug-in communication modules
(1 to max. 4)
6 7
AC500 grows to meet
requirements
Networked and communicative
Control +
communication:
Centralized expansion:
Network
Decentralized expansion:
Modem
8 9
Programming
Offline simulation Configurators of the communication interfaces
IEC 61131-3 commands can be simulated without a For PROFIBUS DP, CANopen, DeviceNet, Ethernet,
PLC being connected, including the relevant mal- Modbus and CS31.
Control Builder AC500
functions. After the program test, the application can
Control Builder AC500 is the engineering tool for all CPU performance classes of the AC500, designed for
be downloaded to the control system. Open interfaces
standardized IEC 61131-3 programming in five different languages. Other features of this tool are: Configurati-
DDE and OPC.
on of the overall system including field buses and interfaces, extensive diagnostic functions, alarm handling,
Sampling trace
integrated visualization and open software interfaces.
Timing diagrams for process variables and storage of Programming
data in a ring buffer with event trigger. Serial or via Ethernet or ARCNET networks.
Values of selected variables are displayed. Pre-defined Provides access from the programming system to an
values can be assigned to variables which can then be external project database in which the program
downloaded to the control system all at once (“Write source code of one or several automation projects is
recipe”). Ongoing values from the control system can also managed. Optionally, a version control system, such
Member of Automation Alliance be pre-assigned for reading into the Watch and Recipe as Visual Source Safe, can be used in order to
Manager, and stored in memory there (“Read recipe). ensure data consistency of the program code for
These functions are also helpful, for example, for setting several different users and projects.
Programming in conformity with IEC 61131-3 ■ Five standardized programming languages:
and entering control parameters. • Comprehensive libraries.
Besides the suitable hardware, a high-performance, Function Block Diagram (FBD), Instruction List (IL),
• Windows 32-bit standard.
user-friendly and convenient engineering tool is Ladder Diagram (LD), Structured Text (ST), Sequen-
Visualization • Operating systems Windows NT, 2000 and XP.
indispensable for simple planning, programming, tial Function Chart (SFC)
Includes color change, moving elements, bitmaps, text
testing and commissioning of an automation applica- ■ Free graphical function chart (CFC)
display, allows input of setpoint values and display of
tion. AC500 Control Builder provides the following ■ Debugging functions for the program test:
process variables read from the PLC, dynamic bar
functionalities: • Single step
diagrams, alarm and event management, function keys
• Single cycle
and ActiveX elements.
• Breakpoint
10 11
CP500 – the operator interfaces
Users can communicate with the AC500’s CPUs via the Depending on the used device type, the operator panels
Obvious man-machine communication
various operator panels, read and write access on feature the following functions:
The AC500 offers as well an extensive range of products for communication between operator and machine.
device data is possible. ■ real-time clock
There are many different displays to choose from, which satisfy application-specific demands regarding
Configuration is quick and easy to perform, using the ■ alarm management in several different groups
required operator actions and information density. Whether it’s a simple device for displaying text, a graphic-
same software for all devices. Commands and program- ■ trend curves and datalogger
capability device or a touch-panel with color display, the entire range of control terminals meets the require-
ming languages are identical for all devices. With regard ■ recipe management
ments for maximized transparency and efficiency for the automation task.
to frequently harsh conditions at the place of installation, ■ report printouts
all operator panels fulfill IP65 protection at the front. ■ password protection
Operator panels and automation devices are linked ■ Flash memory up to 1600 kB
12 13
Communication – Ethernet Communication –
PROFIBUS DP
Ethernet
Ethernet with 100 MBit/s. Ethernet utilizes the producer/consumer (Process Field Bus - Decentral Periphery)
model. This means that every station possesses equal rights. While it is transmitting, all other stations listen PROFIBUS DP is an open, high-speed and widely-used field bus.
in and accept the data directed to them. Bus access is regulated by the CSMA/CD procedure (Carrier- It provides multi-master and master-slave communication in the field
Sense Multiple-Access with Collision Detection), where each station may autonomously transmit when the area. This field bus can accordingly be used for AC500 and AC31 control system series and for field-bus-
bus is free. If a collision occurs, if two stations begin to transmit simultaneously, both of them will stop neutral FBP devices (decentralized I/Os and intelligent switching devices) via the PROFIBUS-FBP connector.
transmission and wait for a randomly determined time before they transmit again. Ethernet defines the
Layers 1 (Physical Link) and 2 (Data Link) of the OSI model. Communication Data exchange
The AC500 supports transmission and reception of data using TCP/IP and/or UDP/IP. Further application The masters rule data traffic on the bus. When in This is handled predominantly in cyclical mode be-
layers can be implemented by subsequent loading. Simultaneous operation of TCP/IP, UDP/IP and applica- possession of the bus access authorization (token), tween master and slave. The requisite communication
tion layer is also assured. The IP, TCP, UDP, ARP, RP, BOOTP, and DHCP protocols are supported as a the masters can transmit data without an external functions have been specified by the PROFIBUS DP
standard feature, as application layer Modbus/TCP. request. The passive devices, known as slaves, do basic functions in accordance with EN 50170. Each
not receive any bus access rights; they acknowledge master has full write and read access to its assigned
Topology Transmission media messages received, or respond to a query from a slaves, but only read access to the slaves assigned to
Star- or ring-shaped using Ethernet hub or switch. Twisted-pair cables with RJ45 connector. The master. Baud rates from 9.6 kBaud to 12 MBaud are other bus masters. There is no direct data exchange
maximum cable length is 100 m for 100 MB/s. supported. A maximum of 126 devices can be between masters. Acyclical services (DP-V1) for
Data transmission operated on the bus. parameterization and diagnostics between master and
Max. 10 MB/s with 10 Base T and max. 100 MB/s Diagnostics slave are also available. This is performed in parallel to
with Fast-Ethernet. Detailed diagnostic messages for rapid trouble- the master’s cyclical user data traffic.
■ Max. 126 subscribers via amplifier and max. 32 subscribers (master/slaves) Detailed diagnostic messages for rapid
Communication – Modbus®
per bus segment trouble-shooting are shown on the
■ Data transmission rate from max. 12 MBit/s with a cable length of 100 m, CPU display. In addition, the device
Modbus® RTU (developed by Modicon in 1979)
up to 93.75 kBit/s with 1200 m status is indicated at the communica-
Modbus® RTU is an open master/slave protocol, and can be easily implemented on serial interfaces.
■ Multi-master or master/slave communication. Bus access of the masters tion module by four LEDs.
Numerous automation systems have Modbus® RTU interfaces as standard or optional features, and are thus
using token
easily able to communicate with the AC500 via its integrated COM1 and COM2 interfaces (RS232 or RS485).
■ Connection of the master CPU and the associated communication module
The Modbus® is used not only in industrial applications, but also in building installations, in energy optimization
via a 9-pole SUB-D plug connector. Connection of slaves (CPU, I/Os and
systems, for long-distance data transmission and for linking up operator panels.
intelligent switching devices) via FieldBusPlug
slave and then receives the response. Both interfaces appended. The telegrams permit process data (input/
COM1 and COM2 can operate simultaneously as output data) to be written and read, either individually
Modbus interfaces. The Modbus operating mode of or in groups. The data are packed in the RTU format.
Transmission media
Topology May vary. One widely used option is the RS485 bus
Point-to-point via RS232 or multi-point via RS485. physics, a twisted-pair, shielded cable with termina-
mum cable length is 15 m with RS232 and 1.2 km Detailed diagnostic messages for rapid trouble-shoot-
16 17
Communication –
CANopen and DeviceNet
DeviceNet The bus operates on the master/slave principle with The bus operates on the multi-master and/or the
The CAN protocol was originally developed for the European auto- one master and up to 127 slaves. A shielded twisted- master/slave principle, with up to 64 bus subscribers.
motive industry, so as to replace expensive cabling by an affordable pair cable is used, according to ISO 11898. Cable Two types of shielded twisted-pair cables are used:
network cable. Today, it is also used in the field of automation for lengths and transmission rates: from max. 40 m at trunk cable for the main line and drop cable for the
transmitting process data between control systems, decentralized 1 MBit/s to 1000 m at 20 kBit/s. branch line.
I/O modules, drives, valves, etc. CAN features a high level of transmission security, since large portions of the
monitoring mechanisms have been implemented directly in the CAN chip. DeviceNet and CANopen utilize the Transmission rate 125 kBit/s 250 kBit/s 500 kBit/s
Max. cable length of trunk line 500 m 250 m 100 m
physical structure and the data transport mechanisms of CAN (Controller Area Network). The difference lies in Trunk cable (1610 ft) (820 ft) (328 ft)
Max. cable length of trunk line 100 m 100 m 100 m
the transmission protocols. DeviceNet and CANopen can be used correspondingly for the AC500 and AC31 Drop cable (328 ft) (328 ft) (328 ft)
Max. cable length per branch line 6m 6m 6m
controller series and for field-bus-neutral FBP devices (decentralized I/Os and intelligent switching devices), via Trunk cable/Drop cable (20 ft) (20 ft) (20 ft)
Max. cable length total branch line 156 m 78 m 39 m
Trunk cable/Drop cable (512 ft) (256 ft) (128 ft)
the CANopen-FBP plug connector.
Two types of message have been defined: I/O data The connection ID with the lower address has higher Detailed diagnostic messages for rapid trouble-
transfer and direct link. I/O data transfer is used for priority on the bus. Data is transmitted by the source, shooting are shown on the CPU display. In addition,
time-critical process data, while the direct link can while the sinks (i.e. receivers of the data) have like- the device status is indicated at the communication
be, for example, used for diagnostic messages. wise been specified during the configuration phase. module by four LEDs.
18 19
Communication – ARCNET
ARCNET
Security mechanisms
A 16-bit CRC is appended to every data packet, and IEEE 802.3i-1990. At 2.5 MBit/s and with coaxial
checked by the recipient. If the token is lost, a recon- cables, for example, the maximum length of a bus
figuration routine will be initiated, and the network will segment is 300 m with eight subscribers and without
automatically be restructured. Additionally, diagnostic a hub. With twisted-pair cables, under the same
ARCNET (Attached Resource Computer NETwork) Physical characteristics sion length depends on the number of connected
ARCNET is an open, multi-purpose field bus solution with real-time capability. It can ABB recommends coaxial cables as transmission subscribers. With coaxial cables, a maximum of
be used for multi-master networking and for programming the AC500 and AC31 medium, for direct connection to the CPU. But also 16 km can be achieved; with twisted-pair cables
controller series, but also for connecting additional ARCNET subscribers, e.g. PCs twisted-pair cables or (glass, plastic) fiber-optic cables approximately 6 km, in each case at 2.5 MBit/s. The
via an appropriate interface card (see catalog). can be connected via bus converters. The line lengths fiber-optic link provides the highest degree of inter-
that can be achieved without any intermediate amp- ference immunity. With glass fiber-optics, distances
lifiers depend not only on the used medium, but also of up to 3 km are possible at 2.5 MBit/s; with plastic
Topology Bus assignments
on the selected baud rate and the number of subscri- fiber-optic cables only small distances of up to approx-
ARCNET is one of the few networks that can be ARCNET operates on the token-passing procedure,
bers. The ranges per segment vary from approximate- imately 100 m. The baud rate plays no significant role
operated in every conceivable topology. Options where each subscriber has equal rights.
ly 120 m for a simple two-wire bus, up to 3 km for in fiber-optic cable transmission. Here, the range can
include bus, star, or tree topologies, or mixtures of
fiber-optics, in each case at 2.5 MBit/s. By providing as well be extended using hubs.
these. This means that ARCNET can be used for a Configuration mechanisms
appropriate hubs, different topologies and transmis-
broad field of different applications. ARCNET allows to add and to remove subscribers
sion media can be combined with each other and the Diagnostics
from the network during runtime. When a new
transmission distance can be increased. The coaxial Detailed diagnostic messages for rapid trouble-
subscriber is added, the entire network will be re-
cables used are a type with 93 Ohm, e.g. RG 62. shooting are shown on the CPU display.
configured.
The permissible twisted-pair cables are specified in
20 21
ARCNET – the functionality at a glance
■ Guaranteed collision-free data transmission, guaranteed response times and real-time capability thanks to
token-passing
■ Secure, thanks to checksums in the data packet and handshake protocol between transmitter and receiver
■ Variable network structure: bus, tree and star topologies are possible, plus any desired mixtures of them
■ Variable networking media, coaxial cables, twisted-pair cables and fiber-optic cables can be mixed
■ Automatic subscriber log-on and log-off; the network automatically incorporates new stations in the ring and CS31
■ Master-master access: the subscriber that holds the token is the master. With up to 255 masters at the same
network
■ ARCNET is configured and programmed using the AC500 Control Builder engineering tool
Is performed at 187.5 kB/s. Each telegram has an 8-bit Detailed diagnostic messages for rapid trouble-
CRC appended. The telegrams enable process data shooting are shown on the CPU display.
CS31 (Communication Serial Field Bus, developed by ABB in 1989) for continuity and migration
(input/output data) to be written and read.
CS31 is a proprietary master/slave field bus. It is characterized by simple handling, easy configuration, and inexpensive
installation. The COM1 interface of the AC500 can be configured as a CS31 field bus master.
Transmission medium
Is handled using polling, i.e. the master sends a Multi-point line, RS485, approved without branch tors. Other transmission media: fiber-optic cables via
request to the slave and then receives the response. lines. A system consists of one master and up to 31 a converter (glass fibers max. 3 km, plastic max.
The CS31 operating mode of COM1 is set using the slaves. The maximum cable length is 500 m, or 2 km 100 m), contact lines, slip rings (bus length max.
engineering tool. with an amplifier. Slaves are primarily decentralized 50 m) and data photocells.
connection.
22 23
Scalable automation system
AC500
DetailsType: PM571 PM571-ETH PM581 PM581-ETH PM581-ARC PM591 PM591-ETH PM591-ARC
Supply voltage 24 V DC 24 V DC 24 V DC 24 V DC
Total memory
SDRAM (kByte) 4026 8192 32768
Flash (kByte) 1024 2048 8192
SRAM (kByte) 128 512 2048
Program memory
Flash EPROM und RAM [kByte] 64 256 4096
Data memory integrated [kByte] 21, incl. 1 KB RETAIN 288, incl. 32 KB RETAIN 3072, incl. 512 KB RETAIN
Binary I/O modules
Plug-in memory card [SD card] 128 MB 128 MB 128 MB
DI524 DC532 DX522 DX531
Cycle time for 1000 instructions in ms
Supply voltage 24 V DC 24 V DC 24 V DC 24 V DC
Binary 0.3 0.15 0.05
Word 0.3 0.15 0.05 Number of binary inputs and outputs
Floating-point 6 3 0.5 DI/DO/DC (configurable channels) 32 /- /- 16 /-/ 16 8 / 8/- 8 /4 /-
24 25
Scalable automation system
AC500
System data
Power failure bridging time according to EN 61131-2
DC-supply Failure < 10 ms, time between 2 failures > 1 s
AC-supply Failure < 0,5 periods, time between 2 failures > 1 s
Temperature
Operation 0 °C ... +55 °C
Storage -25 °C ... +75 °C
Interface modules
Transport -25 °C ... +75 °C
DC505-FBP DC551-CS31
Humidity 50 ... 95 %, without condensation
Field buses PROFIBUS DP*) CS31 Air pressure
CANopen*) Operation > 800 hPa / < 2000 m
DeviceNet*) Storage > 660 hPa / < 3500 m
Modbus RTU*)
Interface via FBP integrated Creepage distances and clearances
Supply voltage 24 V DC 24 V DC The creepage and clearance distances correspond to Overvoltage Category II, Pollution Severity 2
Number of binary inputs and outputs
DI/DO/DC (configurable channels) 8 /-/ 8 8 /- /16
Electromagnetic compatibility
Input voltage 24 V DC 24 V DC
Interference immunity
Input time-relay configurable configurable
against electrostatic discharge (ESD) acc. to EN 61000-4-2, Zone B, Criteria B
0.1 / 1 / 8 / 32 ms 0.1 / 1 / 8 / 32 ms
Interference voltage with air discharge 8 kV
Outputs transistor Interference voltage with contact discharge 6 kV
Output voltage/current 24 V DC/ 0,5 A 24 V DC/ 0,5 A
Total current per module 4A 8A Interference immunity
Short-circuit/overload protection yes yes against radiated interference (CW radiated) acc. to EN 61000-4-3, Zone B, Criteria A
Operating state indicators Test field strength 10 V/m
Supply voltage FBP LED green LED green
FBP communication LED green Interference immunity
CS31 communication LED green against transient interference voltages (burst) acc. to EN 61000-4-4, Zone B, Criteria B
Sumcheck error LED red LED red
I/O bus communication LED green LED green Interference immunity
Status indication for each input/output LED yellow LED yellow against conduction-bound interferences
Supply voltage I/Os LED green LED green (CW conducted) acc. to EN 61000-4-6, Zone B, Criteria A
Fault indicator I/Os LED red LED red Test voltage 3V Zone B
Potential isolation from the bus from the bus
per module per module Impulse voltage acc. to EN 61000-4-5, Zone B, Criteria B
*) depending on the FBP; the Emitted interference acc. to EN 55011, Group 1, Class A
Operating and environmental conditions module itself is field-bus-neutral
Mechanical data
Voltages according to EN 61131-2 Connection type/Terminals
Mounting horizontal
24 V DC Process and Degree of protection IP 20
supply voltage 24 V DC (-15 %, +20 % without residual ripple) Housing acc. to UL 94
Absolute limits 19,2 V ... 30 V incl. residual ripple Vibration-resistance all three axes
Residual ripple < 5% 2 Hz ... 15 Hz, continuous 3,5 mm
Polarity reversal protection 10 s 15 Hz ... 150 Hz, continuous 4 g
120 V AC Supply voltage 120 V AC (-15 %, +10 %) Vibration-resistance with SD card plugged in 15 Hz ... 150 Hz, continuous 1 g
Frequency 47 Hz ... 62,4 Hz/50 ... 60 Hz (-6 %, +4 %) Shock-resistance all three axes
230 V AC Supply voltage 230 V AC (-15 %, +10 %) 15 g, 11 ms, semi-sinusoidal
Frequency 47 Hz ... 62,4 Hz/ 50 ... 60 Hz (-6 %, +4 %) Device mounting
120– 240 V AC Wide voltage input DIN top-hat rail acc. to DIN EN 50022 35 mm, overall height 7.5 mm or 15 mm
Voltage 102 V ... 264 V / 120 V ... 240 V (-15 %, +10 %) Screw mounting Screws with 4 mm diameter
Frequency 47 Hz ... 62,4 Hz/ 50 ... 60 Hz (-6 %, +4 %) Torque
26 27
Operating and displaying
Operator panels CP500 – Overview
CP501 CP502 CP503 CP511 CP512 CP513 CP551 CP552 CP554 CP555
Ident. No. 1SBP 260170 R0101 1SBP 260171 R0101 1SBP 260172 R0101 1SBP 260173 R0101 1SBP 260174 R0101 1SBP 260175 R0101 1SBP 260176 R0101 1SBP 260177 R0101 1SBP 260178 R0101 1SBP 260179 R0101
Display type STN LCD STN LCD STN LCD STN LCD B/W STN LCD TFT 256 Color LCD Touch B/W STN 16 grey levels Touch LCD TFT 256 Color touch LCD TFT 256 Color touch LCD
with backlight with backlight with backlight with backlight with backlight with backlight with backlight with backlight
Representation Text Text Text Graphic and text Graphic and text Graphic and text Graphic and text Graphic and text Graphic and text Graphic and text
Display size 2 lines x 16 characters 2 lines x 20 characters 4 lines x 20 characters 240 x 64 pixels (5.2") 240 x 128 pixels (5.3") 320 x 240 pixels (5.7") 320 x 240 pixels (5.7") 320 x 240 pixels (5.7") 320 x 240 pixels (5.7") 640 x 480 pixels (10.4")
Display area 115.2 x 86.4 78.0 x 58.5 115.2 x 86.4 115.2 x 86.4 211.2 x 158.4
55.7 x 11.0 73.5 x 11.5 70.4 x 20.8 127.2 x 33.9 120.0 x 64.0
W x H (mm)
Text height (mm) 5 5 5 variable variable variable variable variable variable variable
LEDs 5 (2 colors) 16 (2 colors) 16 (2 colors) 16 (2 colours)
16 (8 with 16 (8 with
Function keys 4 3 5 8
labeling strip) labeling strip)
Web functions ● ● ● ● ● ● ●
Buzzer ● ● ● ● ● ● ●
Alarm management 1 group 4 groups 4 groups 16 groups 4 groups 5 groups 5 groups 11 groups
Time channel ● ● ● ● ● ● ● ● ●
Real-time clock ● ● ● ● ● ● ● ● ●
Trend curves real-time developing of values developing of values developing of values developing of values developing of values developing of values
Datalogger ● ● ● ● ●
Recipe management ● ● ● ● ● ● ● ● ●
Report printing ● ● ● ● ● ● ● ● ●
Password protection 8 levels 8 levels 8 levels 8 levels 8 levels 8 levels 8 levels 8 levels 8 levels
Multilanguage ● ● ● ● ●
● ● ● ●
support
Application
16 kB Flash 64 kB Flash 64 kB Flash 400 kB Flash 400 kB Flash 400 kB Flash 400 kB Flash 400 kB Flash 400 kB Flash 1600 kB Flash
memory
Power supply 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC
Current
200 mA 150 mA 150 mA 450 mA 450 mA 550 mA 150 mA 400 mA 450 mA 1A
consumption
Ambient 0 – 50 °C 0 – 50 °C 0 – 50 °C 0 – 50 °C 0 – 50 °C
0 – 50 °C 0 – 50 °C 0 – 50 °C 0 – 50 °C 0 – 50 °C
temperature
RS232, RS422 RS232, RS422 RS232, RS422 RS232, RS422 RS232, RS422
Communication
RS232 or RS422 RS485 (of which RS485 (of which RS232, RS422 RS232, RS422 RS232, RS422 RS485, Ethernet RS485 RS485 RS232, RS422
interfaces
2 at the same time) 2 at the same time) (of which 2 at the same time) (of which 2 at the same time) (of which 2 at the same time)
Expansion slots – – - 1 1 2 - 1 1 2
Degree of protection
IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65
front cover
Dimensions
104 x 69 x 38 142 x 90 x 47,5 147 x 163,5 x 38 211 x 198 x 69 214 x 232 x 87 276 x 198 x 89 142 x 90 x 47,5 200 x 150 x 69 200 x 150 x 69 290 x 250 x 105
W x H x D (mm)
Weight (kg) 0.2 0.5 0.7 1.5 1.4 1.7 0,6 1.5 1.5 3.3
28 29
Ordering data
The AC500 CPU´s
■ 2 serial interfaces integrated, RS232/RS485 configurable
■ Display and 8 function keys for diagnosis and status
■ Centrally expandable with up to 7 expansion modules
■ Up to 4 external communication modules simultaneously and in
any desired combination
■ Optional: SD card for data storage and program backup
Communication module Profibus DP
Profibus DP Master up to 12 MBit/s
A maximum of 4 CM572-DP modules can be operated simultaneously at one CPU
No external power supply required
Type Interface Ordering Number Weight
The AC500, PM571 basic units
1 pc./kg
Type Program- Cycle time ms Integrated Ordering Number Weight
CM572-DP Sub-D socket 1SAP 170 200 R0001
memory 1000 instruct. coupler 1 pc./kg
Bit/Word/Float
PM571 64 KB 0.3 /0.3 / 6 - 1SAP 130 100 R0100 0.135
PM571-ETH 64 KB 0.3 /0.3 / 6 Ethernet 1SAP 130 100 R0170 0.150 Communication module DeviceNet
Type Interface Connector Ordering Number Weight
1 pc./kg
The AC500, PM581 basic units CM575-DN Plug-in Spring-type available 2006
terminal block terminals
Type Program- Cycle time ms Integrated Ordering Number Weight
memory 1000 instruct. coupler 1 pc./kg
Bit/Word/Float
PM581 256 KB 0.15/ 0.15 /3 - 1SAP 140 100 R0100 0.135 Communication module CANopen
PM581-ETH 256 KB 0.15/ 0.15 /3 Ethernet 1SAP 140 100 R0170 0.150
Type Interface Connection Ordering Number Weight
PM581-ARCNET 256 KB 0.15/ 0.15 /3 ARCNET available 2006 0.160
1 pc./kg
CM578-CN Plug-in Spring-type available 2006
terminal block terminals
The AC500, PM591 basic units
Type Program- Cycle time ms Integrated Ordering Number Weight
memory 1000 instruct. coupler 1 pc./kg
Terminal base
Bit/Word/Float
For mounting and connecting the CPUs and communication modules
PM591 4096 KB 0.05 / 0.05 / 0.5 - 1SAP 150 100 R0100 0.135 1 to 4 plug-in communication modules
PM591-ETH 4096 KB 0.05 / 0.05 / 0.5 Ethernet 1SAP 150 100 R0170 0.150 Connection for communication coupler integrated in the CPU
PM591-ARCNET 4096 KB 0.05 / 0.05 / 0.5 ARCNET available 2006 0.160 I/O interface for direct connection of up to 7 expansion modules
Field-bus-neutral FieldBusPlug-Slave interface
Connection COM1: 9-pole with pluggable terminal block
Connection COM2: 9-pole SUB-D (socket)
Communication Module Ethernet
Type No. of Connection for Ordering Number Weight
10/100 MBit/s Full /Half Duplex with auto-sensing
coupler slots coupler integrated 1 pc./kg
2-Port switch integrated
in CPU
Transport protocols TCP/IP, UDP/IP, Modbus TCP
A maximum of 4 CM577-ETH modules can be operated simultaneously at one CPU TB511-ETH 1 Ethernet RJ45 1SAP 111 100 R0170
No external power supply required TB521-ETH 2 Ethernet RJ45 1SAP 112 100 R0170 0.215
TB541-ETH 4 Ethernet RJ45 1SAP 114 100 R0170
Type Protocol Interfaces Ordering Number Weight
TB521-ARCNET 2 ARCNET COAX available 2006
1 pc./kg
CM577-ETH TCP/IP, UDP/IP, Modbus TCP 2 x RJ45 1SAP 170 700 R0001
30 31
Ordering data
Terminal units
For binary and analog expansion modules and interface modules
Please note: for modules with relay outputs, terminal units for 230 V AC
(TU531/TU532) are required!
For module-to-terminal-unit assignments, please consult the table!
Interface modules TU505 TU506 TU515 TU516 TU531 TU532 TU551 TU552
For decentralized I/Os Screw Spring Screw Spring Screw Spring Screw Spring
DC505-FBP Communication via FieldBusPlug with Profibus DP, CANopen, DeviceNet, Modbus DC505-FBP x x
Field-bus-dependent field bus plug required
DC551-CS31 Communication via integrated interface with CS31 system bus DC551-CS31 x x
Plug-in electronic modules, terminal block TU5xx required DI524 x x
DC: Channels can be individually configured as input or output DC532 x x
Type Number of Input signal Output signal Ordering Number Weight DX522 x x
DI/DO /DC 1 pc./kg
DX531 x x
DC505-FBP 8 /-/ 8 24 V DC Trans. 24 V DC, 0.5 A 1SAP 220 000 R0001 0.3
AX522 x x
DC551-CS31 8 / -/16 24 V DC Trans. 24 V DC, 0.5 A available 2006 0.3
32 33
Dimensions Relevant approvals
as well tested in conformity with the applicable Protection of the natural environment is integral to
European, North American and international guideli- ABB’s corporate philosophy. This includes both resour-
nes, and approved by the organizations responsible. ce-economy and the avoidance of problematical
These include GL, DNV, BV, RiNA, LRS and cUL. substances, plus recycling-friendly construction and
The products bear the CE symbol. long-lived products. These aspects are taken fully on
The entire process involved in creating an ABB repeatedly verified by regular eco-audits. And for newly
product – from the original idea to the actual sale – developed products ABB now conducts a lifecycle
AC500 approvals
Lloyd´s
Register Of
Shipping
cUL, USA, Canada GL, Germany DNV, Norway BV, France RINa, Italy LRS, United Kingdom