IB200

EN 50131-1
EN 50131-3
EN 50130-5

I-BUS ISOLATORS

The BUS is the “backbone” of the system. It transmits all


the data from the control panel to the peripherals and vice IB200/P IB200/A
versa, therefore, maximum reliability is always required.
To help installers achieve this goal, INIM offers several BUS IB200/U
isolator versions.

In the IB200/P and IB200/U versions, the isolator protects and regenerates the BUS data signals. In the IB200/A version, the
isolator protects and regenerates the BUS data signals and the power supply.

The isolator allows the confinement of problems caused by malfunction on a downstream branch to that branch only, thus
not allowing malfunctions to affect the upstream branch. The isolator also makes it possible to extend the BUS length thanks
to the signal regeneration function.
The IB200/A is very useful when it is necessary to protect peripheral devices located in unprotected areas against vandalism. If
a device is damaged and BUS functionality is compromised, the isolator, once properly installed within the protected area, will
guarantee the proper functioning of the rest of the system.

IB200/U - dimensions IB200/P - dimensions


107 21
59

80
46.5

97

126 27

IB200/A - dimensions IB200/P - back


80

27 172 9 83 14

IB200/A - back
64

67.7 65.7
IB200
EN 50131-1
EN 50131-3
EN 50130-5

Main features IB200/U IB200/P IB200/A


Galvanic isolation of data (D, S) Yes Yes Yes
Regeneration of data signals (D, S) Yes Yes Yes
Tamper signalling - Yes Yes
I-BUS analysis function Yes Yes Yes
Address programming Yes Yes Yes
Galvanic supply isolation (+, -) Configurable Configurable Yes
Regeneration of BUS supply voltage - - Yes
Input voltage from 9.5 to 15V
Output voltage - - 13.8V
Maximum output current - - 1A
Typical absorption 110mA 110mA 130mA
1.8A @ 9.5Vin
Maximum absorption from control panel - - 1.4A @ 12Vin
1.2A @ 13.8Vin
Dimensions 107x59x21mm 126x80x27mm 172x80x27mm
Weight 60 gr 100g 170g
Security grade 3
Environmental class II

CONNECTION DIAGRAMS
IB200/U, IB200/P
Control panel Cable length Maximum num-
BUS speed downstream of ber of cascaded
ISOLATE
the isolator isolators
Uncut 38.4kbps 500m 9
jumpers
125kbps 350m 6
I-BUS I-BUS 250kbps 200m 2
upstream downstream

IB200/U, IB200/P
Control panel

ISOLATE

Cut
jumpers

I-BUS I-BUS
upstream External downstream
power
supply 13.8V

IB200/A

Control panel

ISOLATE
ORDER CODES

IB200/U:BUS isolator with data regeneration and on-


view terminals
IB200/P: BUS isolator with data regeneration and
I-BUS I-BUS
upstream downstream tamper protection
IB200/A: BUS isolator with data and power regeneration
and tamper protection

Centobuchi, via Dei Lavoratori 10


63076, Monteprandone (AP), ITALY
Tel. +39 0735 705007 _ Fax +39 0735 704912

info@inim.biz _ www.inim.biz Inim distributor’s stamp


and signature

DCSTINE0IB200-110-20200630