Vacuum Device Calibration Certificate

You might also like

Download as pdf
Download as pdf
You are on page 1of 2
IIS TESTING (BD) PVT. LTD. 150 03:2015| CERTIFICATE OF CALIBRATION Date of Recopt: ‘Visual inspection Certfeate Number: Instrument Details Instrument Name: Make: Mode Serial: wo: ange : Resolution: ‘curacy: Calortion| Calibration Procedure Environment Condition : Temperature (C) Relative Humity (RH) sranzarev0210021 tssue Date ‘Vacuum Gauge Wika ENaS7-1 NP NP (©t0-760}mmHg 20mmHg ‘As Per Inetrument At Laboratory nas soweo Date of Calibration ‘Due Dat of Calibration : 28 Feb 2022 27 Feb 2023, 01 Mar 2022, ‘The calibration has been performed under controlled conditions using IIS Testing (BD) Pvt.Ltd. Laboratory reference ‘standards, which are periodically referenced to one or more ofthe primary standards traceable to NPLINIST or other national physical measures as equivalent to NIST. The calibration had been performed in accordance with calibration procedure ISAWU14V (Procedure based on DKD-R6-1). Change in temperature and relative humidity ofthe Laboratory during the calibration was lees than 0.3°C per how and 6.0% per 4 hours respectively. Details of Standard Equipment Used for Calibration : SIN Description | Make/Model IDNo/sRNo. | CalibrationDue | calibrated By 1 | Pressure cotrator Nagmen sport 20 Dee 2022 NUTECH svznzarzroaieaa1 Laboratory Address: House- 169, (3rd Floor), Road- 03, Mohakhali DOHS, Dhaka-1206, Bangladesh. Tel: +88-02-48811446 India Office: Plot No. 29, Haitha Nilayam, Sri Sai Nagar Colony, Kukatpally, Hyderabad-500072, Telanga, india Singapore Office: BLK 473, Choa Chukang, Avenue 3, # 13 ~ 165, Singapore-680473 www iisplbd.com www.iispl.net IIS TESTING (BD) PVT. LTD. 180 9001:2015 CERTIFICATE OF CALIBRATION OBSERVATION : ‘Vacuum Pressure: (verifled agant calibrated instruments) order: St.no, | WUCvVaine (mig) | Sarmervatee ‘Error (mite) Uncertainty oF ° 2 ° a “200 201 o 03 00 ca 2 205% OF Reg oe 500 502) 3 0 “200 “eas 3 08 760 706, é Descending Order: SL.mo. | Uucvalue(mmig) | SBrmorg uae ror (mm) Uncertainty om 760 786. 60. @ "200, 505, 30 03 500) 502. 20 0.5% oF 0 400, 02. 20 ee 05 200) 200) 00. 6 ° ° 00 Notes 1. UUC is defined as Unit Under Calibration 2. The measurement confidence level 95%, 3. Coverage factor ke2. 4. The tresuls are provided as observed without any adjustments 5. Alcalbraton equipments are traceable tothe NationaVintemational Standards. 6. The values mentioned above are the mean readings, 7. This certificate is issued strictly in accordance with the requirements of ISO 170252017, 8. Any section marked, "N/A" means Not Applicable, ‘N/P* means Not Provided, "WIR" means Not Readable, Calibrated By = hh drain Amin (Se-calioration Engineer) S/QF/7.8/01/0; Date of issue: 0/02/2023 End of Report wsranzararo2m021 Laboratory Address: House- 169, (3rd Floor), Road- 03, Mohakhali DOHS, Dhaka-1206, Bangladesh. Tel: +88-02-48811446 India Office: Plot No. 29, Haitha Nilayam, Sri Sai Nagar Colony, Kukatpally, Hyderabad-500072, Telanga, India. Singapore Office: BLK 473, Choa Chukang, Avenue 3, # 13 ~ 165, Singapore-680473 www.iispLnet — www.iispibd.com

You might also like