ELECTRICAL NOTES
84'-1 1/2"
1. ALL ELECTRICAL WORK SHALL COMPLY W/THE LATEST NATIONAL ELECTRICAL CODE (2017), F.B.C. 7TH EDITION (2020) AND ALL
OTHER APPLICABLE CODES.
26'-1 1/2" 33'-9 1/2" 15'-0" 9'-2 1/2"
2. ALL ELECT. WORK TO BE DONE BY A LICENSED ELECTRICAL CONTRACTOR AFTER A PERMIT IS ISSUED.

3. CONDUIT UNDERGROUND TO BE PVC SCHEDULE 40

4. CONDUIT EXPOSED TO WEATHER TO BE IMC.

5. WIRE INSTALLED ELSEWHERE TO BE ROMEX.


NOT MODIFIED IN the hatch selection (e) 2

6. FLEXIBLE CONDUIT SHALL BE SEAL TITE.


2
OFFICe (e)
11'-5 1/2"

7. OUTLETS INSTALLED OUTDOORS, GARAGE AND BATHROOMS SHALL HAVE GROUND FAULT INTERRUPTER

A.C
2 8. ELECTRICAL OUTLETS ( RECEPTACLES AND LIGHTING BELOW BASE FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST
(e) PERMITTED CIRCUITS FROM THOSE IN THE HABITAT AREA.
2

SHED
9. NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEVATION.
ROOF LINE ROOF LINE 2 (e)

10. A/C COMPRESSORS SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION.


S.D (e) 2
2 (e) 2 (e) 11. MAIN CIRCUIT BREAKERS PANELS SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION.
EP CL (e) (e)
2
2 12. IT SUGGESTED THAT YOU CONFER WITH FLORIDA POWER & LIGHT TO LOCATE THE ELECTRICAL METER TO COMPLY WITH
(e)
(e) cl FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS.
+0'-1"
S.D

A.C
(e)
UNIT 1 (e) 13. ALL 120v SINGLE PHASE, 15 AND 20 A BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT
2

A.C
(e) (e) 2
+0'-1" (e) (e) KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, BEDROOMS, CLOSETS, HALLWAYS, LAUNDRY, OR SIMILAR ROOM
0'-0"
2 (e)
UNIT 7 S.D AREAS, SHALL BE PROTECTED BY AFCI BY ANY OF THE MEANS DESCRIBED IN 210.12(A) (1) THROUGH (6). THIS INCLUDE TRASH
(e) 2
4 (e) COMPACTOR AND MICROWAVE OVEN.

14. 90% OF NEW LAMPS MUST BE HIGH EFFICIENCY.


(e) 2 (e)

EP CL
2 (n) (e) 2
(e) (n) 15. IN ALL AREAS SPECIFIED IN 210.52, ALL NONLOCKING-TYPE 125-VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED
S.D

A.C
(e) (e)
-2'-0" TAMPER-RESISTANT RECEPTACLES
(e) 2
2
(n) (e) (e) (e) WET LOCATION NOTES
+0'-1" S.D 2
2

A.C
2 1. ALL ELECTR. EQUIP. EXPOSED TO WEAVER SHALL COMPLY TO NEC 312.2
2 (e) 2 (e) UNIT 2

A.C
(e)
(e) cl 2. SWITCHES OR CIRCUIT BREAKERS IN WET LOCATION OR OUTSIDE OF A BUILDING SHALL BE

-0.5'-0"
+0'-1"
ENCLOSED IN A WEATHERPROOF ENCLOSURE OR CABINET PER NEC. 404.4
S.D 3. NO SWITCHES SHALL BE INSTALLED WITHIN WET LOCATION.
UNIT 8 (e) 2 (e) 2 (e)
2 (e) SMOKE DETECTOR NOTE
S.D SMOKE DETECTOR ALARMS SHOULD BE PLACED OUTSIDE EACH SLEEPING AREA AND ON EVERY
A.C

A.C
A.C

(e) + 0'-0" (e) 2 2 2


LEVEL OF THE HOME. THIS ALARM IS POWERED BY A 10-YEAR SEALED-IN, NON-REPLACEABLE

0'-0"
(n) (n)
LITHIUM ION BATTERY. NO HARDWIRE INSTALLATION REQUIRED AND NO NEED TO CHANGE THE

A.C
(e) BATTERIES OVER THE 10-YEAR LIFE OF THE ALARM. SIMPLY REPLACE THE ENTIRE UNIT AFTER 10
-3'-0" (e)
(e) YEARS.
(e) (e)

12260 SW 8th ST Suite #224


2

83'-2"
(e) 2 (e) (e)

SIDE HALLWAY
(n)

CONSULTING ENGINEER:
-0.5'-0"

A.C

PHONE : (786) 502-2096


(e)
2 (n) (n) 2 (e) +0'-1" -RECESSED LIGHTS OUTSIDE OVERHANG TO BE WEATHER PROOF.
UNIT 3 -RESIDENTIAL STAIRS MIN. 1 FT CANDLE INSIDE AND OUTSIDE STAIRS. FBC R303.6

ARSHAD VIQAR, P.E.


POOL -SMOKE ALARMS ARE REQUIRED INSIDE AND OUTSIDE ALL SLEEPING AREAS. FBC 907.
91'-2"

2 2 2 2 (e) 4 (e) 2 NOTE


2 (e)
(e) (e) (e) 2 (e) (e) SMOKE DETECTOR NOTE

FL. LIC. No. 38863


71'-2"

S.D

MIAMI, FL 33184
(e) SMOKE DETECTOR ALARMS MUST BE WIRED TOGETHER BY LOW VOLTAGE ELECTRICITY RUNNING
(e) 4 (e) 2
THROUGHOUT THE DWELLING, TO THE SAME CRT, AFCI AND SHALL HAVE BATTERY BACKUP AND
SHALL BE LOCATED 3'-0" AWAY FROM ANY DIFFUSERS AND BATHROOM DOOR.
SIDE HALLWAY

(e) (e) +0'-1" +0'-1"

A.C
2 2
EP UNIT 9 UNIT 4 (n)
A.C

2
(e)
(e) ELECTRICAL LEGEND
2 (e) (e) (e)
2 -4'-0" (e) 110 V DUPLEX RECEPTACLE CEILING MOUNTED INCANDESCENT LAMP

A.C
2 (e)
S.D 240V RECEPTACLE CEILING MOUNTED LED
(e) 2
(n) (n) WALL MOUNTED INCANDESCENT LAMP
(e) (e) 2 2 2 110 V DUPLEX RECEPTACLE GFCI
2 S.D
WALL MOUNTED LIGHT FIXTURE.
A.C

(e) 2 (e) 110 V DUPLEX UNDER


(e)
3'-0" 2 COUNTER RECEPTACLE v CEILING MOUNTED VAPOR
(e) 2 (e) 2 2
2 (n)
(e)
(n) 110 V DUPLEX UNDER PROOF FLUORESCENT LAMP
2
S.D

A.C
(e) COUNTER RECEPTACLE GFCI GARBAGE DISPOSAL
SHED

(e)
+0'-1" cl LIGHT SWITCH. SILENT TYPE

A.C
(E) DENOTES EXISTING ITEM TO REMAIN.
2 (e) UNIT 5
(e) (e) 2W
2-WAY LIGHT SWITCH. SILENT TYPE (N) DENOTES NEW ITEM

A.C
ELECTRICAL PANEL 120V SMOKE DETECTOR WITH
2 S.D
2 2 2 ELECTRIC BATTERY BACK-UP.
2 (e) 2 (e) 2 (e) 2(e) M
(e) (e)
(e)
(e)
(e) METER
(e) 2 S.D DISCONNECT SWITCH SMOKE AND CARBON MONOXIDE
(e)
(e) (e) C.M
(e)
DETECTOR WITH BATTERY
SURFACE MOUNTED WRAPAROUND BACK-UP.
+0'-1" +0'-1" (e) 2 2(e) (e) 2 2 WH ROOF LINE FLUORESCENT LIGHT FICTURE NOTE: ALL SMOKE DETECTORS SHALL BE

ELECTRICAL PLAN
2 (e)
(e) UNIT 11 UNIT 10 INTERCONNECTED FOR SIMULTANEOUS
(e) (e) (n)
OPERATION.
2 A.C
A.C

(e) (e)
2 S.D
(e) (n)
S.D (e) S.D
S.D ELECTRICAL
(e)
(e) (e)
2
EP
(e)
2
METER
(e) 2 (e) (e) +0'-1" 2
(e) 2 (e) M
(e) (e) 3 # 2/0 THWN. CU. IN 1-1/2" CONDUIT RGS
(e) 2 2 (e) UNIT 6
(e) (e)
2 (e)
2
2 (e) 2 (e) PANEL 200-A
2 (e) (e) 2 (e) 2 2
(e) (e) 200-A EXISTING PANEL A (120/ 240
A.C
VOLT, 200 AMP. 2 P)
4 (e) EP 2
4 (e) (e)
WH INTERSYSTEM BONDING BLOCK
8'-6 1/2"

+0'-1"
1#1 THNW-3/4" GND
3# 2/0 2"CONDUIT CONNECTED TO TWO 85
" X 10" GROUNDING RODS
LAUNDRY
UNDERGROUND SERVICE SPACED 6' BOND TO A 43" COPPER WATER PIPE
2
S.D (e) TO FPL POWER SUPPLY
(e) STUB-OUT AT METER LOCATION & FOUNDATION STEEL

RODS TO BE DRIVEN 8' MIN. BELOW GRADE


DRAWN BY:
ELECTRICAL RISER DIAGRAM
12'-0 1/2" 26'-7 1/2" 16'-0" 34'-2 1/2" CHECKED BY:
N.T.S.
38'-8" 16'-0" 34'-2 1/2" DATE:
88'-10 1/2" SCALE:

SCOPE OF WORK: SHEET:

- ELECTRICAL SYSTEM EXISTING AND NOT MODIFIED IN THIS PROJECT, except

E2
1 PROPOSED ELECTRIC PLAN where indicated in the drawing.
- relocation of lighting, receptacles and outlets in the areas in
E-2 SCALE: 3/16"= 1'-0" question.