Critical Hidden Beam Check

Between Axes 5 , 6 in the 1st Floor


Screenshot (1)
Screenshot (2)

1
* Calculating Load /m2 of a One-Way Hollow Block Slab

Screenshot (3)
* Calculating Load /m2 of a One-Way Hollow Block Slab

Screenshot (4)
2.45m
1.45m 1m
Beam (1)
Load /m’ = ( 1 + 1.45 ) * Load/m2 = 4.1 t/m’

4.1 t/m’

6.40 m

Reaction = (w*L) / 2 = ( 4.1 * 6.4 *0.5 ) =


13.12 ton
13.12 t This Reaction is then redirected to the Critical 13.12 t
Beam (2)
4.10m
13.12 t 2.60m

6.70m
Beam (2) [ 100 x 32 ]
O.W. = γc * b * t = 2.5 * 1 * 0.32 = 0.8 t/m’

O.W. = 0.8 t/m’

6.70 m

W ∗ L2
= 4.5 m. t
8
P = 13.12 t

a = 4.10 m b = 2.60 m
L = 6.70 m

P ∗ a ∗ b 13.12 ∗ 4.1 ∗ 2.6


= = 20.9 m. t
L 6.70
Mu Total = MO.W. + Mconcentrated = 4.5 + 20.9 = 25.4 m.t

Screenshot from RC-Design-U-2017-v12.8.xlsx


By Dr. Mahmoud El-Kateb

Beam Current Dimensions are adequate and no need


to increase Width or Depth according to provided
Calculation Notes