Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

COLUMN

BARS DESCRIPTION SHAPE LENGTH


400
MAIN BARS 12 - 25 0 4.124
575
5-25 0
620
5-25 0 4L-12 0 @135c/c OUTER STIRRUPS 2L-10 0 @135c/c 620 2.68

237
INNER STIRRUPS 2L-10 0 @135c/c 620 1.91

BEAM
4L-10 0 @135c/c BARS DESCRIPTION SHAPE LENGTH

TOP MAIN BARS 5 - 25 0 300 300 5.1

5-25 0 BOT. MAIN BARS 5 - 25 0 325 325 5.1


5-25 0 5-25 0 1st. LAYER

BOT. MAIN BARS 5 - 25 0 375 375 5.1


2nd. LAYER
SPACER BAR
640
5-25 0 OUTER STIRRUPS 2L-12 0 @135c/c 2.71
640

12-25 0 12-25 0 345


INNER STIRRUPS 2L-12 0 @135c/c 640 2.11

FOOTING
4-25 0 BARS DESCRIPTION SHAPE LENGTH
4L-10 0 @135c/c 4L-10 0 @135c/c
TOP BARS 10 0 @135c/c 300 300 2.50

10 0 @135c/c

12 0 @135c/c
BOT. BARS 12 0 @135c/c 300 300 2.50
4L-10 0 @135c/c

10 0 @135c/c
2-25 0 2-25 0

COLUMN 700 x 700

10 0 @135c/c FOOTING 2000 x 2000


12 0 @135c/c 12 0 @135c/c
12 0 @135c/c
4-25 0

REVISIONS CLIENT DESIGN CONSULTANT


EMPLOYER: KONKAN RAILWAY CORPORATION LTD.
JOB TITLE - IN201007
PROJECT: CONSULTANCY FOR MAINTENANCE AND REHABILITATION OF CUTTINGS, EMBANKMENTS AND TUNNELS IN
KONKAN RAILWAY CORPORATION LTD. THE KARJAT - LONAVALA SECTION OF CENTRAL RAILWAY

TITLE NAME SIGN. DATE Title


AMBERG ENGINEERING AG
CLIENT APPROVED Trockenloostrasse, Postfach 27 Drawn DKR 11-12-2021 FALSE PORTAL OF T-35 BB END
CH-8105 Regensdorf-Watt Drawing Review D. BARMAN 11-12-2021
GENERAL ARRANGEMENT & REINFORCEMENT DETAILS

0 11-12-2021 DrB Designed DrB 11-12-2021


Drawing Status
ISSUE FOR APPROVAL DKR D.BARMAN SCALE Original Size Drawing No. Rev
AS SHOWN 0
No Date DESCRIPTION BY CHK. APP. AEN / DESIGN DY CE / DESIGN CE / DESIGN Approved DrB 11-12-2021 A1 FINAL IN201007-FLD-T35-FL-0007