FSLM P19-P20

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 9

NAME OF PROJECT:MUMBAI AHMEDABAD HIGH SPEED RAIL PROJECT (PACKAGE- C4)

Threading Report Girder:- 232P19-232P20 ( Intermediate)


Longitudinal Report Transverse Report Transverse Report
No. of Act - A Act - E No. of No. of
Tendon Coil no. Tendon Coil no. Act - A value Act - E value Tendon Coil no. Act - A value Act - E value
strands value value strands strands
C1-1L 12 T1 4 T21 4
C1-1R 12 T2 4 T22 4
C1-2L 12 Y3220A 145.18 202.00 T3 4 T23 4
C1-2R 12 Y3220A 145.18 202.00 T4 4 T24 4
C2-1L 12 T5 4 T25 4
C2-1R 12 T6 4 T26 4
C2-2L 12 Y3220A 145.18 202.00 T7 4 T27 4
C2-2R 12 Y3220A 145.18 202.00 T8 4 T28 4
C3-1L 12 T9 4 T29 4
C3-1R 12 T10 4 T30 4
C3-2L 12 Y3220A 145.18 202.00 T11 4 T31 4
C3-2R 12 Y3220A 145.18 202.00 T12 4 T32 4
C4-1L 12 T13 4 T33 4
C4-1R 12 T14 4 T34 4
C4-2L 12 Y3219B 145.74 194.00 T15 4 T35 4
C4-2R 12 Y3219B 145.74 194.00 T16 4 T36 4
C5-1L 12 T17 4 T37 4
C5-1R 12 T18 4 T38 4
C5-2L 12 Y3219B 145.74 194.00 T19 4 T39 4
C5-2R 12 Y3219B 145.74 194.00 T20 4 T40 4
C6-1L 12 Y3219B 145.74 194.00
C6-1R 12 Y3219B 145.74 194.00
C6-2L 12
C6-2R 12 Threading done towards Upside Chainage
C6-3L 12 Y3219E 145.42 199.00
C6-3R 12 Y3219E 145.42 199.00

DSI L&T Engineer


NAME OF PROJECT:MUMBAI AHMEDABAD HIGH SPEED RAIL PROJECT
(PACKAGE- C4 , CH-238)

CALCULATION OF MODIFIED PRESSUE AND MODIFIED ELONGATION (MAHSRP C4)


GIRDER ID : P13- P14
A. CALCULATION OF MODIFIED PRESSURE
Cable No. SLAB SLAB
Cable Type 4S15 4S15
= 756 KN = 756 KN
Total Force in Cable (As per Drawing) = 77.065 T = 77.065 T
F' 77065 KG 77065 KG
Jack Type
Jack Number
Ram Area of Jack 'A' = cm2 = cm2
Efficiency of jack ( Achieved after Jack Efficiecy Test) En ' = % = %
Pressure to Be Applied 'P' = (Force/(Area*Efficiency)) F' /'A' x 'En' ~ #DIV/0! Kg/cm2 ~ #DIV/0! Kg/cm2
Maximum Allowable Pressure 1.05 x 'P' ~ #DIV/0! Kg/cm2 ~ #DIV/0! Kg/cm2

B. CORRECTION FACTOR:

Coil Number TATA WIRON


Theoretical Area of Strand At = 140 mm2 = 140 mm2
Theoritical 'E' of Strand Et = 195000 N/mm2 = 195000 N/mm2
Actual Area of Strand (As per Coil MTC, Assumed) Aa = mm2 = mm2
Ea = KN/mm2 = KN/mm2
Actual 'E' of Strand (As per Coil MTC, Assumed)
= 0 N/mm2 = 0 N/mm2
Correction Factor C.F. = At X Et / Aa x Ea = #DIV/0! = #DIV/0!

C.ELONGATION
Elongation In cable No. C1-1 from anchor body to anchor body (inclusive of
A'
slip of 8 mm, As per Drawing)
= 80.20 mm = 80.20 mm
D. ELONGATION IN JACKING/GRIIPING LENGTH
Gripping Length of Jack 'B' = 0.47 m = 0.47 m
Elongation per metre ( In Gripping Length, PL/AE) C' 6.92 mm 6.92 mm
Elongation in Gripping Length of Jack D = 'B' x 'C' = 3.25 mm = 3.25 mm
GROSS ELONGATION E=A+D 83.5 83.5
MODIFIED ELONGATION M.E. = E x C.F. ~ #DIV/0! ~ #DIV/0!
Limit of Elongation is + 5%
Elongation ( 95% ) : ME x 0.95 ~ #DIV/0! mm ~ #DIV/0! mm
Elongation ( 105% ) : ME x 1.05 ~ #DIV/0! mm ~ #DIV/0! mm

For DSI For L&T For Engineer


NAME OF PROJECT:MUMBAI AHMEDABAD HIGH SPEED RAIL PROJECT
(PACKAGE- C4 )
CALCULATION OF MODIFIED PRESSUE AND MODIFIED ELONGATION FOR TRANSVERSE TENDON (MAHSRP C4)

GIRDER ID & TYPE :- 232P19-232P20 ( Intermediate)


A. CALCULATION OF MODIFIED PRESSURE
Cable No. SLAB SLAB SLAB SLAB
Cable Type 4S15 4S15 4S15 4S15
= 813 KN = 813 KN = 813 KN = 813 KN
Total Force in Cable (As per Drawing) = 82.875 T = 82.875 T = 82.875 T = 82.875 T
F' 82875 KG 82875 KG 82875 KG 82875 KG
Jack Type 1919-CDC-100-150 1919-CDC-100-150 1919-CDC-100-150 1919-CDC-100-150
Jack Number 70145 70146
Ram Area of Jack 'A' = 161.98 cm2 = 161.98 cm2 = cm2 = cm2
Efficiency of jack ( Achieved after Jack Efficiecy Test) En' = 98.62 % = 99.83 % = % = %
Pressure to Be Applied 'P' = (Force/Area) F' /'A' x 'En' ~ 519 Kg/cm2 ~ 513 Kg/cm2 ~ #DIV/0! Kg/cm2 ~ #DIV/0! Kg/cm2
Maximum Allowable Pressure 1.05 x 'P' ~ 545 Kg/cm2 ~ 538 Kg/cm2 ~ #DIV/0! Kg/cm2 ~ #DIV/0! Kg/cm2

B. CORRECTION FACTOR:

Coil Number TATA WIRON Y3094D Y3094D


Theoretical Area of Strand At = 140 mm 2
= 140 mm2 = 140 mm2 = 140 mm2
Theoritical 'E' of Strand Et = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2
Actual Area of Strand (As per Coil MTC, Assumed) Aa = 145.10 mm2 = 145.10 mm2 = #N/A mm2 = #N/A mm2
Ea = 202.00 KN/mm2 = 202.00 KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2
Actual 'E' of Strand (As per Coil MTC, Assumed)
= 202000 N/mm2 = 202000 N/mm2 = #N/A N/mm2 = #N/A N/mm2
Correction Factor C.F. = At X Et / Aa x Ea = 0.931 = 0.931 = #N/A = #N/A

C.ELONGATION
A'
Elongation In cable from anchor body to anchor body (inclusive of slip of 8
= 86.30 mm = 86.30 mm = 86.30 mm = 86.30 mm
mm, As per Drawing)
D. ELONGATION IN JACKING/GRIIPING LENGTH
Gripping Length of Jack 'B' = 0.55 m = 0.55 m = 0.55 m = 0.55 m
Elongation per metre ( In Gripping Length, PL/AE) C' 6.92 mm 6.92 mm 6.92 mm 6.92 mm
Elongation in Gripping Length of Jack D = 'B' x 'C' = 3.81 mm = 3.81 mm = 3.81 mm = 3.81 mm
GROSS ELONGATION E=A+D 90.11 90.11 90.11 90.11
MODIFIED ELONGATION M.E. = E x C.F. ~ 83.93 ~ 83.93 ~ #N/A ~ #N/A
Limit of Elongation is + 5%
Elongation ( 95% ) : ME x 0.95 ~ 80 mm ~ 80 mm ~ #N/A mm ~ #N/A mm
Elongation ( 105% ) : ME x 1.05 ~ 88 mm ~ 88 mm ~ #N/A mm ~ #N/A mm
For DSI For L&T For Engineer
NAME OF PROJECT:MUMBAI AHMEDABAD HIGH SPEED RAIL PROJECT
(PACKAGE- C4)

CALCULATION OF MODIFIED PRESSUE AND MODIFIED ELONGATION FOR LONGITUDINAL TENDON (MAHSRP C4)

GIRDER ID & TYPE : 232P19-232P20 ( Intermediate) Stage -1

A. CALCULATION OF MODIFIED PRESSURE

Cable No. C1-2L C1-2R C2-2L C2-2R C3-2L C3-2R C4-2L C4-2R C6-3L C6-3R C6-1L C6-1R C5-2L C5-2R

Cable Type 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15

= 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN
Total Force in Cable (As per Drawing) = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T
F' 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG

Jack Type 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250

Jack Number 69077 & 69078 69079 & 69080 69077 & 69078 69079 & 69080 69077 & 69078 69079 & 69080 69077 & 69078 69079 & 69080 69077 & 69078 69077 & 69078 69077 & 69078 69079 & 69080 69077 & 69078 69079 & 69080

Ram Area of Jack 'A' = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2

Efficiency of jack ( Achieved after Jack Efficiecy Test) En' = 99.24 % = 99.8 % = 99.24 % = 99.8 % = 99.24 % = 99.8 % = 99.24 % = 99.8 % = 99.24 % = 99.24 % = 99.24 % = 99.8 % = 99.24 % = 99.8 %

Pressure to Be Applied 'P' = (Force/Area*Efficiency) F'/'A' x 'En' ~ 441 Kg/cm2 ~ 439 Kg/cm2 ~ 441 Kg/cm2 ~ 439 Kg/cm2 ~ 441 Kg/cm2 ~ 439 Kg/cm2 ~ 441 Kg/cm2 ~ 439 Kg/cm2 ~ 441 Kg/cm2 ~ 441 Kg/cm2 ~ 441 Kg/cm2 ~ 439 Kg/cm2 ~ 441 Kg/cm2 ~ 439 Kg/cm2

432.87 bar 430.44 bar 432.87 bar 430.44 bar 432.87 bar 430.44 bar 432.87 bar 430.44 bar 432.87 bar 432.87 bar 432.87 bar 430.44 bar 432.87 bar 430.44 bar

Maximum Allowable Pressure 1.05 x 'P' ~ 463 Kg/cm2 ~ 461 Kg/cm2 ~ 463 Kg/cm2 ~ 461 Kg/cm2 ~ 463 Kg/cm2 ~ 461 Kg/cm2 ~ 463 Kg/cm2 ~ 461 Kg/cm2 ~ 463 Kg/cm2 ~ 463 Kg/cm2 ~ 463 Kg/cm2 ~ 461 Kg/cm2 ~ 463 Kg/cm2 ~ 461 Kg/cm2

B. CORRECTION FACTOR:

Coil Number TATA WIRON Y3220A Y3220A Y3220A Y3220A Y3220A Y3220A Y3219B Y3219B Y3219E Y3219E Y3219B Y3219B Y3219B Y3219B

Theoretical Area of Strand At = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2

Theoritical 'E' of Strand Et = 195000 N/mm 2


= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm2

Actual Area of Strand (As per Coil MTC) Aa = 145.18 mm2 = 145.18 mm2 = 145.18 mm2 = 145.18 mm2 = 145.18 mm2 = 145.18 mm2 = 145.74 mm2 = 145.74 mm2 = 145.42 mm2 = 145.42 mm2 = 145.74 mm2 = 145.74 mm2 = 145.74 mm2 = 145.74 mm2

Ea = 202 KN/mm = 2
202 KN/mm = 2
202 KN/mm = 2
202 KN/mm = 2
202 KN/mm = 2
202 KN/mm = 2
194 KN/mm = 2
194 KN/mm = 2
199 KN/mm = 2
199 KN/mm = 2
194 KN/mm = 2
194 KN/mm = 2
194 KN/mm = 2
194 KN/mm2
Actual 'E' of Strand (As per Coil MTC)
= 202000 N/mm2 = 202000 N/mm2 = 202000 N/mm2 = 202000 N/mm2 = 202000 N/mm2 = 202000 N/mm2 = 194000 N/mm2 = 194000 N/mm2 = 199000 N/mm2 = 199000 N/mm2 = 194000 N/mm2 = 194000 N/mm2 = 194000 N/mm2 = 194000 N/mm2
C.F. = At X Et / Aa
Correction Factor x Ea = 0.931 = 0.931 = 0.931 = 0.931 = 0.931 = 0.931 = 0.966 = 0.966 = 0.943 = 0.943 = 0.966 = 0.966 = 0.966 = 0.966

C.ELONGATION
Elongation In cable from anchor body to anchor
A'
body (inclusive of slip of 8 mm, As per Drawing) = 128.10 mm = 128.10 mm = 127.80 mm = 127.80 mm = 127.35 mm = 127.35 mm = 126.90 mm = 126.90 mm = 128.90 mm = 128.90 mm = 128.90 mm = 128.90 mm = 126.50 mm = 126.50 mm

D. ELONGATION IN JACKING/GRIIPING LENGTH

Gripping Length of Jack 'B' = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m

Elongation per metre ( In Gripping Length, PL/AE) C' 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm

Elongation in Gripping Length of Jack D = 'B' x 'C' = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm

GROSS ELONGATION E=A+D 132.18 132.18 131.88 131.88 131.43 131.43 130.98 130.98 132.98 132.98 132.98 132.98 130.58 130.58

MODIFIED ELONGATION M.E. = E x C.F. ~ 123.05 ~ 123.05 ~ 122.77 ~ 122.77 ~ 122.35 ~ 122.35 ~ 126.47 ~ 126.47 ~ 125.45 ~ 125.45 ~ 128.40 ~ 128.40 ~ 126.09 ~ 126.09

Elongation ( 95% ) : ME x 0.95 ~ 117 mm ~ 117 mm ~ 117 mm ~ 117 mm ~ 116 mm ~ 116 mm ~ 120 mm ~ 120 mm ~ 119 mm ~ 119 mm ~ 122 mm ~ 122 mm ~ 120 mm ~ 120 mm

Elongation ( 105% ) : ME x 1.05 ~ 129 mm ~ 129 mm ~ 129 mm ~ 129 mm ~ 128 mm ~ 128 mm ~ 133 mm ~ 133 mm ~ 132 mm ~ 132 mm ~ 135 mm ~ 135 mm ~ 132 mm ~ 132 mm

For DSI For L&T For Engineer


NAME OF PROJECT:MUMBAI AHMEDABAD HIGH SPEED RAIL PROJECT
(PACKAGE- C4)

CALCULATION OF MODIFIED PRESSUE AND MODIFIED ELONGATION FOR LONGITUDINAL TENDON (MAHSRP C4)

GIRDER ID & TYPE : 232P18-232P19 ( CENTRE POLE) Stage -1

A. CALCULATION OF MODIFIED PRESSURE

Cable No. C1-2L C1-2R C2-2L C2-2R C3-2L C3-2R C4-2L C4-2R C6-3L C6-3R C6-1L C6-1R C5-2L C5-2R

Cable Type 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15

= 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN
Total Force in Cable (As per Drawing) = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T
F' 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG

Jack Type 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250

Jack Number 69081 & 69082 69077 & 69078 69081 & 69082 69077 & 69078 69081 & 69082 69077 & 69078 69081 & 69082 69077 & 69078 69081 & 69082 69081 & 69082 69081 & 69082 69077 & 69078 69081 & 69082 69077 & 69078

Ram Area of Jack 'A' = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2

Efficiency of jack ( Achieved after Jack Efficiecy Test) En' = 99.17 % = 98.72 % = 99.17 % = 98.72 % = 99.17 % = 98.72 % = 99.17 % = 98.72 % = 99.17 % = 99.17 % = 99.17 % = 98.72 % = 99.17 % = 98.72 %

Pressure to Be Applied 'P' = (Force/Area*Efficiency) F'/'A' x 'En' ~ 457 Kg/cm2 ~ 459 Kg/cm2 ~ 457 Kg/cm2 ~ 459 Kg/cm2 ~ 457 Kg/cm2 ~ 459 Kg/cm2 ~ 457 Kg/cm2 ~ 459 Kg/cm2 ~ 457 Kg/cm2 ~ 457 Kg/cm2 ~ 457 Kg/cm2 ~ 459 Kg/cm2 ~ 457 Kg/cm2 ~ 459 Kg/cm2

448.07 bar 450.11 bar 448.07 bar 450.11 bar 448.07 bar 450.11 bar 448.07 bar 450.11 bar 448.07 bar 448.07 bar 448.07 bar 450.11 bar 448.07 bar 450.11 bar

Maximum Allowable Pressure 1.05 x 'P' ~ 480 Kg/cm2 ~ 482 Kg/cm2 ~ 480 Kg/cm2 ~ 482 Kg/cm2 ~ 480 Kg/cm2 ~ 482 Kg/cm2 ~ 480 Kg/cm2 ~ 482 Kg/cm2 ~ 480 Kg/cm2 ~ 480 Kg/cm2 ~ 480 Kg/cm2 ~ 482 Kg/cm2 ~ 480 Kg/cm2 ~ 482 Kg/cm2

B. CORRECTION FACTOR:

Coil Number TATA WIRON Y3220A Y3220A Y3220A Y3220A Y3220A Y3220A Y3219B Y3219B Y3219E Y3219E Y3219B Y3219B Y3219B Y3219B

Theoretical Area of Strand At = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2

Theoritical 'E' of Strand Et = 195000 N/mm 2


= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm2

Actual Area of Strand (As per Coil MTC) Aa = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2

Ea = #N/A KN/mm = 2
#N/A KN/mm = 2
#N/A KN/mm = 2
#N/A KN/mm = 2
#N/A KN/mm = 2
#N/A KN/mm = 2
#N/A KN/mm = 2
#N/A KN/mm = 2
#N/A KN/mm = 2
#N/A KN/mm = 2
#N/A KN/mm = 2
#N/A KN/mm = 2
#N/A KN/mm = 2
#N/A KN/mm2
Actual 'E' of Strand (As per Coil MTC)
= #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2
C.F. = At X Et / Aa
Correction Factor x Ea = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A

C.ELONGATION
Elongation In cable from anchor body to anchor
A'
body (inclusive of slip of 8 mm, As per Drawing) = 132.50 mm = 132.50 mm = 132.20 mm = 132.20 mm = 131.75 mm = 131.75 mm = 131.25 mm = 131.25 mm = 133.35 mm = 133.35 mm = 133.35 mm = 133.35 mm = 130.85 mm = 130.85 mm

D. ELONGATION IN JACKING/GRIIPING LENGTH

Gripping Length of Jack 'B' = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m

Elongation per metre ( In Gripping Length, PL/AE) C' 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm

Elongation in Gripping Length of Jack D = 'B' x 'C' = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm

GROSS ELONGATION E=A+D 136.73 136.73 136.43 136.43 135.98 135.98 135.48 135.48 137.58 137.58 137.58 137.58 135.08 135.08

MODIFIED ELONGATION M.E. = E x C.F. ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A

Elongation ( 95% ) : ME x 0.95 ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm

Elongation ( 105% ) : ME x 1.05 ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm

For DSI For L&T For Engineer


NAME OF PROJECT:MUMBAI AHMEDABAD HIGH SPEED RAIL PROJECT
(PACKAGE- C4 )
CALCULATION OF MODIFIED PRESSUE AND MODIFIED ELONGATION FOR LONGITUDINAL TENDON (MAHSRP C4)

GIRDER ID & TYPE : 232P19-232P20 ( Intermediate) Stage -2

A. CALCULATION OF MODIFIED PRESSURE

Cable No. C1-1L C1-1R C2-1L C2-1R C3-1L C3-1R C6-2L C6-2R C4-1L C4-1R C5-1L C5-1R

Cable Type 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15

= 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN
Total Force in Cable (As per Drawing)
= 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T
F'
231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG

Jack Type 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250

Jack Number 69081 & 69082 69075 & 69076 69081 & 69082 69075 & 69076 69081 & 69082 69075 & 69076 69081 & 69082 69075 & 69076 69081 & 69082 69075 & 69076 69081 & 69082 69075 & 69076

Ram Area of Jack 'A' = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2

Efficiency of jack ( Achieved after Jack Efficiecy Test) En' = 99.32 % = 99.76 % = 99.32 % = 99.76 % = 99.32 % = 99.76 % = 99.32 % = 99.76 % = 99.32 % = 99.76 % = 99.32 % = 99.76 %

Pressure to Be Applied 'P' = (Force/Area*Efficiency) F'/'A' x 'En' ~ 441 Kg/cm 2


~ 439 Kg/cm 2
~ 441 Kg/cm 2
~ 439 Kg/cm 2
~ 441 Kg/cm 2
~ 439 Kg/cm 2
~ 441 Kg/cm 2
~ 439 Kg/cm 2
~ 441 Kg/cm 2
~ 439 Kg/cm 2
~ 441 Kg/cm 2
~ 439 Kg/cm2

432.52 bar 430.61 bar 432.52 bar 430.61 bar 432.52 bar 430.61 bar 432.52 bar 430.61 bar 432.52 bar 430.61 bar 432.52 bar 430.61 bar

Maximum Allowable Pressure 1.05 x 'P' ~ 463 Kg/cm2 ~ 461 Kg/cm2 ~ 463 Kg/cm2 ~ 461 Kg/cm2 ~ 463 Kg/cm2 ~ 461 Kg/cm2 ~ 463 Kg/cm2 ~ 461 Kg/cm2 ~ 463 Kg/cm2 ~ 461 Kg/cm2 ~ 463 Kg/cm2 ~ 461 Kg/cm2

B. CORRECTION FACTOR:

Coil Number TATA WIRON 0 0 0 0 0 0 0 0 0 0 0 0

Theoretical Area of Strand At = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2

Theoritical 'E' of Strand Et = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2

Actual Area of Strand (As per Coil MTC) Aa = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2

Ea = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2
Actual 'E' of Strand (As per Coil MTC)

= #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2

Correction Factor C.F. = At X Et / Aa x Ea = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A

C.ELONGATION
Elongation In cable from anchor body to anchor body (inclusive of A'
slip of 8 mm, As per Drawing) = 129.40 mm = 129.40 mm = 129.05 mm = 129.05 mm = 128.70 mm = 128.70 mm = 128.90 mm = 128.90 mm = 128.30 mm = 128.30 mm = 127.90 mm = 127.90 mm

D. ELONGATION IN JACKING/GRIIPING LENGTH

Gripping Length of Jack 'B' = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m ###
=

Elongation per metre ( In Gripping Length, PL/AE) C' 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm

Elongation in Gripping Length of Jack D = 'B' x 'C' = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm = 4.08 mm

GROSS ELONGATION E=A+D 133.48 133.48 133.13 133.13 132.78 132.78 132.98 132.98 132.38 132.38 131.98 131.98

MODIFIED ELONGATION M.E. = E x C.F. ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A

Elongation ( 95% ) : ME x 0.95 ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm

Elongation ( 105% ) : ME x 1.05 ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm

For DSI For L&T For Engineer


NAME OF PROJECT:MUMBAI AHMEDABAD HIGH SPEED RAIL PROJECT
(PACKAGE- C4 )
CALCULATION OF MODIFIED PRESSUE AND MODIFIED ELONGATION FOR LONGITUDINAL TENDON (MAHSRP C4)

GIRDER ID & TYPE : 232P18-232P19 ( CENTRE POLE) Stage -2

A. CALCULATION OF MODIFIED PRESSURE

Cable No. C1-1L C1-1R C2-1L C2-1R C3-1L C3-1R C6-2L C6-2R C4-1L C4-1R C5-1L C5-1R

Cable Type 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15 12S15

= 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN = 2346 KN
Total Force in Cable (As per Drawing)
= 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T = 239.144 T
F'
239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG 239144 KG

Jack Type 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250 1889-CDC 300 -250

Jack Number 69081 & 69082 69077 & 69078 69081 & 69082 69077 & 69078 69081 & 69082 69077 & 69078 69081 & 69082 69077 & 69078 69081 & 69082 69077 & 69078 69081 & 69082 69077 & 69078

Ram Area of Jack 'A' = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2 = 527.79 cm2

Efficiency of jack ( Achieved after Jack Efficiecy Test) En' = 99.17 % = 98.72 % = 99.17 % = 98.72 % = 99.17 % = 98.72 % = 99.17 % = 98.72 % = 99.17 % = 98.72 % = 99.17 % = 98.72 %

Pressure to Be Applied 'P' = (Force/Area*Efficiency) F'/'A' x 'En' ~ 457 Kg/cm 2


~ 459 Kg/cm 2
~ 457 Kg/cm 2
~ 459 Kg/cm 2
~ 457 Kg/cm 2
~ 459 Kg/cm 2
~ 457 Kg/cm 2
~ 459 Kg/cm 2
~ 457 Kg/cm 2
~ 459 Kg/cm 2
~ 457 Kg/cm 2
~ 459 Kg/cm2

448.07 bar 450.11 bar 448.07 bar 450.11 bar 448.07 bar 450.11 bar 448.07 bar 450.11 bar 448.07 bar 450.11 bar 448.07 bar 450.11 bar

Maximum Allowable Pressure 1.05 x 'P' ~ 480 Kg/cm2 ~ 482 Kg/cm2 ~ 480 Kg/cm2 ~ 482 Kg/cm2 ~ 480 Kg/cm2 ~ 482 Kg/cm2 ~ 480 Kg/cm2 ~ 482 Kg/cm2 ~ 480 Kg/cm2 ~ 482 Kg/cm2 ~ 480 Kg/cm2 ~ 482 Kg/cm2

B. CORRECTION FACTOR:

Coil Number TATA WIRON 0 0 0 0 0 0 0 0 0 0 0 0

Theoretical Area of Strand At = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2

Theoritical 'E' of Strand Et = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2 = 195000 N/mm2

Actual Area of Strand (As per Coil MTC) Aa = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2 = #N/A mm2

Ea = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2 = #N/A KN/mm2
Actual 'E' of Strand (As per Coil MTC)

= #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2 = #N/A N/mm2

Correction Factor C.F. = At X Et / Aa x Ea = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A = #N/A

C.ELONGATION
Elongation In cable from anchor body to anchor body (inclusive of A'
slip of 8 mm, As per Drawing) = 133.85 mm = 133.85 mm = 133.50 mm = 133.50 mm = 133.15 mm = 133.15 mm = 133.35 mm = 133.35 mm = 132.70 mm = 132.70 mm = 132.30 mm = 132.30 mm

D. ELONGATION IN JACKING/GRIIPING LENGTH

Gripping Length of Jack 'B' = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m = 0.59 m ###
=

Elongation per metre ( In Gripping Length, PL/AE) C' 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm 7.16 mm

Elongation in Gripping Length of Jack D = 'B' x 'C' = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm = 4.23 mm

GROSS ELONGATION E=A+D 138.08 138.08 137.73 137.73 137.38 137.38 137.58 137.58 136.93 136.93 136.53 136.53

MODIFIED ELONGATION M.E. = E x C.F. ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A ~ #N/A

Elongation ( 95% ) : ME x 0.95 ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm

Elongation ( 105% ) : ME x 1.05 ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm ~ #N/A mm

For DSI For L&T For Engineer


NAME OF PROJECT:MUMBAI AHMEDABAD HIGH SPEED RAIL PROJECT
(PACKAGE- C4 , CH-238)

CALCULATION OF MODIFIED PRESSUE AND MODIFIED ELONGATION (MAHSRP C4)


GIRDER ID : P13-P14
A. CALCULATION OF MODIFIED PRESSURE
C6-2 B.P C6-2 PIER SIDE C4-1 B.P C4-1 PIER SIDE C5-1 B.P C5-1 PIER SIDE
12S15 12S15 12S15 12S15 12S15 12S15
2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN = 2268 KN
231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T = 231.193 T
231193 KG 231193 KG 231193 KG 231193 KG 231193 KG 231193 KG
1848-CDC-300-250 1848-CDC-300-250 1848-CDC-300-250 1848-CDC-300-250 1848-CDC-300-250 1848-CDC-300-250
66743 & 66744 66739 & 66740 66743 & 66744 66739 & 66740 66743 & 66744 66739 & 66740
490.09 cm2 = 490.09 cm2 = 490.09 cm2 = 490.09 cm2 = 490.09 cm2 = 490.09 cm2
99.01 % = 99.02 % = 99.01 % = 99.02 % = 99.01 % = 99.02 %
476 Kg/cm2 ~ 476 Kg/cm2 ~ 476 Kg/cm2 ~ 476 Kg/cm2 ~ 476 Kg/cm2 ~ 476 Kg/cm2
500 Kg/cm2 ~ 500 Kg/cm2 ~ 500 Kg/cm2 ~ 500 Kg/cm2 ~ 500 Kg/cm2 ~ 500 Kg/cm2

B. CORRECTION FACTOR:

B3948C B3948C B3940E B3940E B532480388 B532480388

140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2 = 140 mm2
195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm 2
= 195000 N/mm2
144.46 mm2 = 144.46 mm2 = 144.05 mm2 = 144.05 mm2 = 142.22 mm2 = 142.22 mm2
193.954 KN/mm2 = 193.954 KN/mm2 = 194.522 KN/mm2 = 194.522 KN/mm2 = 195.500 KN/mm2 = 195.500 KN/mm2
193953.51 N/mm2 = 193953.51 N/mm2 = 194522.49 N/mm2 = 194522.49 N/mm2 = 195500 N/mm2 = 195500 N/mm2
0.974 = 0.974 = 0.974 = 0.974 = 0.982 = 0.982

C.ELONGATION

128.90 mm = 128.90 mm = 128.30 mm = 128.30 mm = 127.90 mm = 127.90 mm

0.94 m = 0.94 m = 0.94 m = 0.94 m = 0.94 m = 0.94 m


6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm 6.92 mm
6.50 mm = 6.50 mm = 6.50 mm = 6.50 mm = 6.50 mm = 6.50 mm
135.4 135.4 134.8 134.8 134.4 134.4
132 ~ 132 ~ 131 ~ 131 ~ 132 ~ 132
Limit of Elongation is + 5%
125 mm ~ 125 mm ~ 125 mm ~ 125 mm ~ 125 mm ~ 125 mm
139 mm ~ 139 mm ~ 138 mm ~ 138 mm ~ 139 mm ~ 139 mm

You might also like