General PDMS Commands

SR COMMANDS USES

1 SAVEWORK TO SAVE THE LATEST WORK

2 GET WORK TO GET THE LATEST MODEL

3 AXES AT CE TO SHOW THE AXES OF CE (CURRENT ELEMENT)

4 AXES OFF TO OFF THE AXES

5 DELETE CE TO DELETE THE CE

6 FLIP CE TO FLIP THE CE

7 CHE CE TO CHECK THE CONSISTENCY OF CE

8 COL ACT BLUE TO CHANGE THE ACTIVE COLOR TO BLUE

9 COL CE GREEN TO CHANGE THE CE COLOR TO GREEN

10 COL 39 VIOLET TO CHANGE THE LINE COLOR TO VIOLET

11 ADD CE TO ADD CURRENT ELEMENT TO DISPLAY

12 ADD SITE TO ADD THE CE SITE TO DISPLAY

13 REM ALL TO REMOVE ALL THE ELEMENTS FROM DISPLAY

14 REM CE TO REMOVE THE CE FROM DISPLAY


TO REMOVE ALL THE ELEMENTS FROM DISPLAY EXCEPT CURRENT
15 REM ALL ADD CE
ELEMENT (CE)
16 Q SPRE TO GET THE CE SPECIFICATION REFERENCE

17 Q REF TO GET THE CE REFERENCE NUMBER

18 Q ATT TO GET THE CE ATTRIBUTES

19 Q COL ACT TO KNOW THE ACTIVE ELEMENT COLOR

20 Q COL CE TO KNOW THE CE COLOR

21 Q MTO TO GET THE CE MTO STATUS

22 Q NAM/Q CE TO GET THE CE NAME

23 Q NVOL TO GET THE CE NET VOLUME


24 Q NWEI TO GET THE CE NET WEIGHT

25 Q OWN TO GET THE CE OWNER ELEMENT NAME

26 Q POS TO GET THE CE CO-ORDINATES/ORIGIN POINT

27 LOCK ALL TO LOCK THE CE & IT’S MEMBER

28 RENAME /XXX/YYY TO RENAME THE CE TO YYY

29 MAR CE TO MARKS THE CE NAME

30 UNLOCK ALL TO UNLOCK THE CE & IT’S MEMBER

31 UNM CE TO UNMARK THE CE NAME

32 ALP REQ CLEAR TO CLEAR THE COMMAND SPACE


REPR HOLES OFF TO OFF THE HOLES REPRESENTATION & UPDATE THE GRAPHICAL
33
UPDATE VIEW
34 STAT TO GET THE STATUS

35 UNCLAIM ALL TO UNLOCK THE CLAIMED MEMBERS

36 Q POS $Q TO GET HELP

37 QUIT TO EXIT THE PDMS WITHOUT SAVING THE WORK

38 FINISH TO EXIT THE PDMS AFTER THE SAVING THE WORK

39 Q MDB TO DISPLAY THE CURRENT MULTIPLE/MASTER DATA BASE

40 Q USER TO DISPLAY THE ACTIVE USER NAME

41 Q MEM TO SHOW THE CE MEMBERS

42 FN+F1 HELP BUTTON

43 FN+F2 TO ZOOM IN/OUT

44 FN+F3 TO MOVE TO PAN ICON

45 FN+F4 TO GET THE PARALLEL/PERSPECTIVE VIEW

46 FN+F5 TO ROTATE

47 FN+F6 TO ON/OFF THE WALK

48 FN+F7 TO ROTATE WRT MODEL


49 FN+F8 TO CONVERT THE DRAWING SOLID TO WIRE AND VICE VERSA

50 FN+F9 TO ON/OFF SCROLL BAR

51 UPDATE ALL TO UPDATE THE CHANGES MADE IN THE DRAWING

52 AXES ON TO SHOW THE AXES ON DISPLAY


TO GET THE FOLLOWING INFORMATION- MDB, DATE, AND USER
53 Q SESSION
NAME
54 1 OR 3 TO ZOOM OUT

55 7 OR 9 TO ZOOM IN

56 $M TO LOAD A MACRO FILE

57 F4+LEFT ARROW TO ROTATE LEFT

58 F6+RIGHT ARROW TO ROTATE RIGHT

59 F2+DOWN ARROW TO ROTATE DOWNWARD

60 F8+UP ARROW TO ROTATE UPWARD

Piping PDMS Commands


SR COMMANDS USES

1 Q BORE TO GET THE PIPE INSIDE DIAMETER

2 Q HPOS TO GET THE CE PIPE HEAD CO-ORDINATES

3 Q ISPEC TO GET THE CE INSULATION SPECIFICATION

4 Q PA TO GET THE CE ARRIVE CO-ORDINATES

5 Q PL TO GET THE CE LEAVE CO-ORDINATES

6 Q PARA TO GET THE CE PARAMETERS

7 Q PH TO GET THE CE PIPE HEAD ATTRIBUTES

8 Q PH BORE TO GET THE CE PIPE HEAD BORE

9 Q PH OD TO GET THE CE PIPE HEAD DIAMETER

10 Q PT OD TO GET THE CE PIPE TAIL DIAMETER

11 Q PT TO GET THE CE PIPE TAIL ATTRIBUTES


12 Q TPOS TO GET THE CE PIPE TAIL CO-ORDINATES

13 DELETE BRAN TO DELETE THE CURRENT BRANCH

14 Q ABORE TO GET THE CE ARRIVE BORE OF A COMPONENT

15 Q LBORE TO GET THE CE LEAVE BORE OF A COMPONENT

16 Q PT BORE TO GET THE CE PIPE TAIL BORE

17 AXES AT PH TO POSITION THE AXES AT PIPE HEAD

18 AXES AT PT TO POSITION THE AXES AT PIPE TAIL

19 NEW ELBOW CHOO TO CREATE A NEW ELBOW

20 Q HREF TO GET THE HEAD REFERENCE OF THE CE BRANCH

21 Q TREF TO GET THE TAIL REFERENCE OF THE CE BRANCH

22 Q DIR TO CHECK THE DIRECTION OF A CURRENT COMPONENT


TO CONNECT THE BRANCH HEAD TO THE FIRST MEMBER OF
23 CONN PH TO FIR MEM
CURRENT BRANCH
TO CONNECT THE BRANCH TAIL TO THE LAST MEMBER OF
24 CONN PT TO FIR MEM
CURRENT BRANCH
25 CONN TO CONNECT

26 NEXT CONN TO CONNECT WITH THE NEXT COMPONENT

27 F CONN TO FORCE CONNECT

28 Q DTXR TO GET THE DESCRIPTION OF A COMPONENT

29 Q MODE TO CHECK THE DIRECTION (FORWARD/BACKWARD)

30 FOR TO CHANGE DIRECTION TO FORWARD MODE

31 BACK TO CHANGE DIRECTION TO BACKWARD MODE

32 MTOC UNSET TO REMOVE THE COMPONENT FROM MTO REPORT

33 MTOC OFF TO ADD BACK THE REMOVED COMPONENT FROM MTO LIST

34 CLEAR 100 TO GIVE THE SPOOL LENGHT 100 MM

35 BY D 100 TO MOVE THE CE 100 MM DOWN

36 BY U 100 TO MOVE THE CE 100 MM UP


37 BY L 100 TO MOVE THE CE 100 MM LEFT

38 BY R 100 TO MOVE THE CE 100 MM RIGHT

39 Q TPOS TO KNOW THE HEAD POSITION

40 Q HPOS TO KNOW THE TAIL POSITION

Structural PDMS Commands


SR COMMANDS USES

1 Q POSS WRT /* TO GET THE START POINT OF STRUCTURE

2 Q POSE WRT /* TO GET THE END POINT OF STRUCTURE

3 Q ORI TO GET THE ORIENTATION OF A STRUCTURE

4 Q POS WRT /* TO GET THE CE CO-ORDINATES W.R.T. WORLD

5 EXTEND 1000 TO EXTEND THE STRUCTURE 1000 MM

6 Q JUS TO GET THE STRUCTURE JUSTIFICATION POINT

7 AXES AT POSS TO ALLOCATE THE AXES AT STRUCTURE’S START POINT

8 AXES AT POSE TO ALLOCATE THE AXES AT STRUCTURE’S ENDPOINT

9 JUSLINE TOS TO CHANGE THE JUSTIFICATION POINT TO TOP OF THE STRUCTURE


TO CHANGE THE JUSTIFICATION POINT TO BOTTOM OF THE
10 JUSTLINE BOS
STRUCTURE
11 Q NPOS TO GET THE NODE POSITION

12 Q JUSL TO GET THE CE JUSTIFICATION LINE

13 Q CTYE TO GET THE CE END CONNECTION POINT

14 Q CTYS TO GET THE CE START CONNECTION POINT

15 Q DESP TO GET THE DESIGN PARAMETER

Equipment PDMS Commands


SR COMMANDS USES
NEW CYLI DIA 500 HEI
1 TO CREATE A CYLINDER OF DIAMETER 500 AND HEIGHT 1000
1000
NEW BOX XLEN 1000 Y TO CREATE A NEW BOX WITH LENGHT 1000, WIDTH 800, AND
2
LEN 800 ZLEN 500 HEIGHT 500
3 AXES AT P1 TO GET THE AXES AT P POINT NUMBER 1

4 AXES AT P2 TO GET THE AXES AT P POINT NUMBER 2

Pipe Support Commands


SR COMMANDS USES

1 Q HH TO GET THE CE HANGER HEAD CO-ORDINATES

2 Q HT TO GET THE CE HANGER TAIL CO-ORDINATES

Draft Commands
SR COMMANDS USES

1 Q BSRF TO GET THE ATTACHED DRAWING/SHEET

2 Q BTEX TO GET THE DEAD TEXT ATTRIBUTES

3 Q CHEI TO GET THE TEXT CHARACTER HEIGHT

4 Q DDNAME TO GET THE DIMENSION OWNERS NAME

5 Q DIR TO GET THE VIEW DIRECTION

6 Q DMTXT TO GET THE DIMENSION TEXT ATTRIBUTE

7 Q ADEG TO GET THE VIEW ANGLE

8 Q APOF TO GET THE CE TERMINATOR POSITION

9 Q LVIS TO GET THE CE VISIBILITY

10 Q PKEY TO GET THE P-LINE STATUS

You might also like