Professional Documents
Culture Documents
MOP of HSPA+ Throughput Improvement Solution Implementation XL Network ...
MOP of HSPA+ Throughput Improvement Solution Implementation XL Network ...
1. Objective
Provide a guideline to deploy XL HSPA Throughput Improvement Solution.
2. Software Version
RNC: BSC6900 UMTS V900R013ENGC00SPH552
NodeB: WCDMA V200R013C00SPC339
2
_________________________________________________________________________________________________
Step 1 Run the BSC6900 MML command LST ESN and record the Equipment Serial
Number (ESN) of the BSC.
Step 2 Run the BSC6900 MML command DLD LICENSE to download the license file from
the FTP server to the \ftp\license directory of the main area directory of the OMU.
Step 3 Run the LST LICENSE command and enter the filename of the license to be
activated to query the file information.
3
_________________________________________________________________________________________________
If… Then…
The file information complies with the Go to Step 4.
information of the file that you apply
for,
The file information does not comply Exit the task and contact Huawei.
with the information of the file that you
apply for,
Step 4 Run the LST CFGMODE command to query the BSC6900 configuration status. If the
BSC6900 is ineffective, run the SET CFGDATAEFFECTIVE command to switch it to
the effective state.
4
_________________________________________________________________________________________________
5
_________________________________________________________________________________________________
If resource control item values are incorrectly set, the total number of resources used by
NodeBs may exceed the maximum available resource number specified in the license, and
the license may fail to be allocated to NodeBs. In this case, the M2000 reports the EVT-513
6
_________________________________________________________________________________________________
The Amount of Used NodeB License's Resource Exceeds the Threshold event, and you
need to set the resource control items and allocate the license to NodeBs again.
If setting resource control item values fails or the resource control item values used by
NodeBs are inconsistent with the corresponding values set on the M2000, the M2000
reports the EVT-514 Changes in the Usage of NE License Resources event, and you need to
synchronize the license allocation information saved.
SET UCORRMALGOSWITCH:DRASWITCH=DRA_BASE_COVER_BE_TTI_RECFG_SWITCH-
1&DRA_DCCC_SWITCH-1;
Deactivation Procedure
SET UCORRMALGOSWITCH:DraSwitch=DRA_BASE_COVER_BE_TTI_RECFG_SWITCH-0;
CAUTION
Before activating this feature, check the settings of the following two parameters: if Reference
7
_________________________________________________________________________________________________
E-TFCI Index1 is set to 4 and Reference E-TFCI Power Offset1 is set to 12, you are advised to set
Reference E-TFCI Power Offset1 to 8.
MOD
UTYPRABHSUPAPC:RABINDEX=14,SUBFLOWINDEX=0,TRCHTYPE=TRCH_EDCH_10MS,UL16QAMIND=F
ALSE,ULL2ENHANCEIND=FALSE,EDPWRINTERPOLATIONIND=FALSE,REFETFCINUM=D1,REFETFCIIDX1=
4,REFETFCIPO1=PO_8/15,ULECBOOSTINGIND=FALSE;
SET UCORRMALGOSWITCH:PCSWITCH=PC_HSUPA_DATA_CH_PO_ADAPTIVE_ADJ_SWITCH-
1,MAPSWITCH=MAP_HSUPA_TTI_2MS_SWITCH-1;
SET UEDCHRATEADJUSTSET:EDCHRATEADJUSTSET=RATE_128KBPS-1&RATE_256KBPS-
1&RATE_608KBPS-1&RATE_2048KBPS-1;
SET UFRC:HsupaInitialRate=D256;
2. Activation Procedure in the Scenario Where Dynamic CE Takes Effect(DCCC does not take
effect)
Deactivation Procedure
Deactivation Procedure
8
_________________________________________________________________________________________________
4) Run script below and test UL throughput and record the result for the selected site,
ADD UCELLHSDPCCH: CELLID=xxx,CQIFbCk=D8,CQIFbCkforSHO=D8;
MOD UPRACHUUPARAS: CELLID=xxx, PHYCHID=4,CONSTANTVALUE=-
30,PREAMBLERETRANSMAX=30, POWERRAMPSTEP=1;
9
_________________________________________________________________________________________________
9) Enable HSUPA PO Auto-adaptive Reconfiguration. But this switch will be on when feature is activated
SET UCORRMALGOSWITCH: PcSwitch=PC_HSUPA_DATA_CH_PO_ADAPTIVE_ADJ_SWITCH-
1;
10
_________________________________________________________________________________________________
PERSON IN CHARGE
Please write down each PIC and contact number during execution, escalation matrix and standby
person in case emergency situation happened
11