Liebert® EXSTM

10 to 80 kW
Optimized and integrated
three-phase UPS solution
with high efficiency power
protection
Liebert® EXS™ 10 to 80 kW

Liebert® EXS from 10 to 80 kW


Compact design and improved
performances
The new Liebert® EXS is 97,00%
a monolithic transformer-free UPS
which brings exceptional features 96,50%
for mission-critical applications. Its
extraordinary double conversion 96,00%
efficiency up to 96.2% ensures
remarkable operational cost 95,50%
savings, reducing both the Total
Cost of Ownership (TCO) and the 95,00%
environmental impact.
At the same time, with its unity 94,50%
output power factor and high
power density, Liebert EXS is able 94,00%
to provide the utmost active 20% 30% 40% 50% 60% 70% 80% 90% 100%
power possible in a compact
footprint. In fact, its improved
design reduces its footprint to Liebert EXS 10-80 kVA efficiency curve
a minimum, providing continuous
power protection with optimized
internal runtime in a standalone
solution, making the Liebert EXS
perfect for both IT installations and
other mission critical applications,
such as transportation, emergency CENTRAL POWER SUPPLY SYSTEM
lighting, healthcare, retail and
government facilities. (CPSS)
Liebert EXS can be used for CPSS applications*
FEATURES AND as defined in the EN 50171 standard, and is hence
capable of supplying the necessary emergency
PERFORMANCES power to essential safety equipment. In fact, the
y Adopts three level t-type unit can be used to power emergency escape
IGBT converter topology lighting in case of normal supply failure and may
yyOutput power factor up to 1 also be suitable for powering other safety systems
such as automatic fire extinguishing installations,
yyDouble conversion efficiency
signaling safety installations and smoke extraction
up to 96.2%
equipment.
yyECO mode efficiency up to * Subject to additional prescriptions
99%
yyCompact footprint with
multiple internal runtime RAILWAYS APPLICATIONS
configurations Liebert EXS can be used for railways applications
yyAvailable in 3/3 and 3/1 as defined in the EN 50121 standard, and it's hence
versions (10-20 kVA) capable of supplying power to specific systems in
urban stations and ensure high reliability to critical
yyIntegrated maintenance
buildings.
bypass
In fact, the unit can be used to power on passenger
yyIntegrated input and output information panels, safety signaling equipment,
breakers/switches ticket machines as well as IT rooms and
yyParallel capability for capacity administration and control offices.
and redundancy
Flexibility
To ensure superior protection for Integrated Autonomy Full Galvanic Isolation
critical loads, the Liebert® EXS (10-60kVA) Liebert EXS offers integrated full
range has been designed to galvanic isolation, meaning that an
Liebert EXS provides an optimized
optimize specific rating isolation transformer may be
integrated autonomy which
requirements, thus enhancing housed inside the UPS cabinet.
results in back up times in a
flexibility and installation space This greatly reduces the system
compact footprint.
needs. footprint, thus providing space
Its internal architecture is able to
Liebert EXS’s flexibility is further house up to four battery strings, saving advantages.
enhanced through: further optimizing integrated The transformer may be
yySingle and three phase output autonomy and delivering the connected to the input or to the
configurations up to 20 kVA added advantage of virtually output of the UPS, providing:
yyIntegrated parallel capability up eliminating the need for an yyFull galvanic isolation for
to 4 units external battery cabinet. medical and other critical
This furthermore reduces applications
yyCommon or distributed battery
installation costs and minimizes
bank yyInstallation with two
the demand on physical space. In
yyInternal and external battery independent input sources
addition, Liebert EXS’s powerful
configurations for optimized (with different neutrals)
battery charger ensures rapid
back up time management recharge, increasing its ability to yyInstallation in distribution
yyCasters for easy UPS manage longer back up times. without neutral.
repositioning

Output Configuration EXS 10-20 kVA with integrated battery EXS 10-20 kVA with integrated battery
(up to two strings) strings (up to four strings)
Liebert EXS models up to 20 kVA
can be configured on-site to
deliver three (3/3) or single (3/1) UPS UPS
phase output giving it the
flexibility to adapt to changes in 1300 1300
installation environments. Battery Battery

650 650
335 242 335

Liebert EXS architecture

READY FOR EXS 30-40 kVA with


integrated batteries
EXS 60 kVA with
integrated batteries
EXS 80 kVA

UPS UPS

1600 UPS
1600 1600
Battery Battery

750 850 850


440 600 600

Liebert EXS architecture

3
Liebert® EXS™ 10 to 80 kW

In The Field
Parallel Ready
Liebert EXS can be connected Automatic AC Bypass
with up to four units in parallel. A AC Normal AC Normal AC Normal AC Normal
single unit can be upgraded to
parallel operation via easy to
modify software settings, allowing
the system to be customized for
the requested configuration. The
loop parallel connection used in
paralleling the system delivers
ultimate reliability and eliminates
the possibility of a single point of
failure, ensuring perfect load Load

sharing and fast detection of any Liebert EXS - Parallel configuration


variation in the system status.

Intelligent Paralleling Feature


Activating the Intelligent Automatic AC Bypass
Paralleling Mode optimizes AC Normal AC Normal AC Normal AC Normal
efficiency at partial load, thus
achieving greater operational cost
savings. Enabling this feature
allows the system to automatically
adapt capacity to meet immediate
load requirements by switching
40%
excess units to standby mode, For units at 40% load
while ensuring continued system each = 95.5% efficiency.
availability. Furthermore, this mode
allows each Liebert EXS unit to Load
operate in standby mode for the Liebert EXS - Inteligent Parelleling
same amount of time, ensuring an
equal life span of module
components. Automatic AC Bypass
AC Normal AC Normal AC Normal AC Normal

Fault Tolerance Feature1


The Liebert EXS provides
enhanced fault tolerance at partial
load versus a traditional fixed 66%
capacity monolithic UPS. It can
For units at 66% load
tolerate internal power module each= >96% efficiency.
failures and still support a partial
load without going to bypass.
Load
Thereby, enhances the availability
of your critical load. Liebert EXS - Inteligent Parelleling

1.Applicable for 60 &80kVA variants.


Communication Serviceability
VERTIV™ TRELLIS™
Liebert® EXS features a multi- The architecture of the Liebert
lingual LCD user interface allowing Vertiv Trellis platform is a EXS is designed to optimize
close control and monitoring of real-time infrastructure installation and simplify service
system status and performance. optimization platform that with its easily removable power
The UPS off ers the following enables the unified assembly. This architecture
communication features: management of data center IT considerably minimizes the time
Liebert EXS’s flexibility is further and facilities infrastructure. needed for repairs and optimizes
enhanced through: The Vertiv Trellis platform serviceability. Liebert EXS also
yyVoltage-free contacts software can manage comes equipped with casters to
yyIntellislot for SNMP, Modbus or capacity, track inventory, plan facilitate ease of movement and
Relay communication changes, visualize relocation.
configurations, analyze and
yyUSB interface
calculate energy usage, and
These communication capabilities optimize cooling and power
make Liebert EXS compatible equipment as well as enable
with any building management for virtualization.
system. The Vertiv Trellis platform
monitors the data center,
providing a thorough
Software Connectivity understanding of system
Vertiv™ shutdown software off dependencies to help IT and
ering prevents unexpected server facilities organizations keep
shutdowns and minimizes the data center running at
downtime warning of pending peak performance. This
power losses and initiating safe unified and complete solution,
shutdown of operating systems if delivers the power to see the
required. Vertiv Nform™ network real situation in your data
communications system enables center, make the right
customers to leverage the decision and take action with
distributed monitoring capabilities confidence.
of network connected equipment,
providing centralized management
of distributed systems.

IS-Relay
Relay Card

IS-Unity-DP
10 - 20 kVA 30 - 40 kVA 60 kVA 80 kVA
Card

5
Liebert® EXS™ 10 to 80 kW

VERTIV™ LIFE™ Services Remote Diagnostic and Preventive Monitoring

Vertiv's service program is First Time Fix Rate Fast Incident Response
designed to ensure that your Pro-active monitoring and data Vertiv LIFE Services allow for
critical power protection system is measuring ensure that when our immediate definition of the best
maintained in an optimum state of customer engineers are course of action, as a result of the
readiness at all times. dispatched on-site, they arrive regular communication between
prepared for first time resolution. your Liebert EXS system and our
The Vertiv LIFE™ Services remote Vertiv LIFE Service centers.
diagnostic and preventive Proactive Analysis
monitoring service provides early Reporting
From Vertiv LIFE Service centers,
warning of UPS conditions and out
our experts proactively analyze the You will receive a comprehensive
of tolerances. This allows effective
data and trends of your equipment, report detailing the working order
proactive maintenance, fast
to recommend actions to ensure of your equipment and its
incident response and remote
their best performance. operational performance.
troubleshooting, giving customers
complete security and peace of
mind. With Vertiv LIFE Services Minimized Total Cost of
you will benefit from: Ownership of Your Equipment
The continuous monitoring of all
relevant parameters in turn
Uptime Assurance maximizes unit performance,
Constant monitoring of UPS reduces on-site maintenance and
parameters, thus maximizing the extends the life of your equipment.
system’s availability.
Technical Specifications

Ratings (kVA / kW ) 10 15 20 30 40 60 80
Input

Nominal input voltage 380 / 400 / 415 V (three-phase + N + PE)

Input voltage range without battery discharge 173 to 498 V* 228 to 475 V*

Nominal frequency 50/60 Hz

Input frequency range 40 to 70 Hz

Input power factor at full load 0.99 kW / kVA

Current THD at full linear load ≤ 3 %*

Bypass voltage tolerance selectable from + 20 % to - 40 %

Bypass frequency tolerance ± 20 % (± 10 % selectable)

Battery

Battery blocks per string 24 to 40* 26 to 40*

Voltage temperature compensation -3.0 mV / °C / Cell

Battery charger max. current 13 A 12.5 A 25 A

Output

380 / 400 / 415 V (three-phase + N + PE) or


Nominal output voltage 380 / 400 / 415 V (three-phase + N + PE)
220 / 230 / 240 V (single-phase + N + PE)

Nominal output frequency 50/60 Hz

Maximum active power 10 kW 15 kW 20 kW 30 kW 40 kW 60 kW 80 kW

THDv at full linear load 2%

105 % for 60 min; 125 % for 5 min; 150 % for 1 min; 105 % for 60 min; 125 % for 10 min; 150 % for 1 min;
Inverter overload capacity
> 150 % for 200 ms > 150 % for 200 ms

Double conversion efficiency Up to 96.2 %*

ECO mode efficiency Up to 99 %

Dimensions and weight

335 x 650 x 1300 mm (standard version)


Dimensions (W x D x H) 440 x 750 x 1600 mm 600 x 850 x 16001 mm
577 x 650 x 1300 mm (extended version)
Net / Shipping weight2 85 / 115 kg (standard version) 170 / 200 kg 215 / 245 kg 230 / 260 kg

General

Noise at 1 m ≤58 dBA <60 dBA

Maximum altitude 1500 m without derating (max. 3000 m)

Operating Temperature up to 50 °C* up to 40 °C

Protection level IEC (60529) IP20 (IP31 is optional3)

General and safety requirements for UPS EN/IEC/AS 62040-1

EMC requirements for UPS EN/IEC/AS 62040-2

UPS classification according to IEC EN 62040-3 VFI-SS-111

Note:
* Conditions apply.
1. Height of the EXS 80 kVA UPS with top ventilation option is 1805 mm
2. Weight is excluding the battery and transformer
3. IP 31 option is available in EXS 20-80 kVA variants

7
Vertiv.com | Asia Pacific
© 2019 Vertiv Co. All rights reserved. Vertiv, and the Vertiv logo trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their
respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for
any errors or omissions. Speci ications are subject to change without notice.