Power Transmission Trainer

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

POWER TRANSMISSION TRAINER

Overview
The Power Transmission Trainer consists of step-up and
step-down transformers, overhead line models and loads.
It allows to simulate real AC transmission lines and
investigate mechanisms of decreasing the loses on the
lines, protection from real-simulated earth-short circuits
and line-to-line short circuits, and reactive power
compensation. It allows also to investigate the power
transformer characteristics.

YouTube Link: https://youtu.be/5rCyL1Pvywo

List of Experiments
Power transmission channel structure
Voltage transformation in power transmission
Loses and power quality distortions during power
transmission
Reactive power compensation in power transmission
Protection during emergencies in power transmission
channels

Power Transmission Trainer Hardware Pictures

email: sales@issyam.com / pt.issyam@gmail.com

Power Labs Ecosystem™


Technical Brief Description | Educational Labs | bitlismen.com
email: sales@issyam.com / pt.issyam@gmail.com Page 1 of 3
Power Transmission Trainer Software Screenshots

email: sales@issyam.com / pt.issyam@gmail.com

Power Labs Ecosystem™


Technical Brief Description | Educational Labs | bitlismen.com
email: sales@issyam.com / pt.issyam@gmail.com Page 2 of 3
SPECIFICATION

Overhead transmission lines : 3-sections. Based on resistive, capacitive and inductive components.
Each section corresponds to 25km line for 132kV
Includes fault switches for line-to-line and line-to-earth short circuits
Transformer : 3-phase star-star, 380VAC primary, 20.76VAC secondary, 100W
Transformer step-up : 3-phase star-star, 20.76VAC primary, 41.52VAC secondary, 200W
Transformer step-down : 3-phase star-star, 41.52VAC primary, 20.76VAC secondary, 200W
3-phase voltage regulator : 3-phase star-star, 20.76VAC primary, 0-23.7VAC secondary controllable, 5kVA
Resistive Load : Variable resistor 50 Ohm, 100W, per each phase. Has built-in overcurrent protection
Capacitive Load : 3-stage capacitors 250uF each, per each phase
Inductive Load : 3-stage inductance 28mH each, per each phase. Has built-in overcurrent protection
Control & Measurement Module: Based on re-programmable real-time controller.
Has also built-in re-programmable FPGA. All is programmed in LabVIEW.
Has built-in overcurrent protection.
*667 MHz processor, *256MB DDR3 memory, *512MB non-volatile memory, *WiFi, *USB 2 port,
*8 power input channels for voltage and current measurement, 300Vrms, 10Arms, 7.8kS/s/ch, 24-bit,
*32 digital input/output channels, 24VDC, 100mA

Software : The software is fully developed in LabVIEW. Open source code is provide.
Each practical experiment has its UI on the software.
The measurements are represented in graphs and on digital indicators.
The trainer can be controlled both manually and from the software

email: sales@issyam.com / pt.issyam@gmail.com

Power Labs Ecosystem™


Technical Brief Description | Educational Labs | bitlismen.com
email: sales@issyam.com / pt.issyam@gmail.com Page 3 of 3