PROGRAMMABLE PRECISION
1
REFERENCE
DESCRIPTION
1
The UTC TL431A is a three-terminal adjustable regulator
with a guaranteed thermal stability over applicable SOT-89 TO-92
temperature ranges. The output voltage may be set to any
value between Vref(approximately 2.5V) and 36V with two
external resistors. It provides very wide applications,
including shunt regulator, series regulator, switching
regulator, voltage reference and others. 2
1
FEATURES 3
*Programmable output Voltage to 36V.
*Low dynamic output impedance 0.2Ω. SOT-23 SOP-8
*Sink current capability of 1 to 100mA.
*Equivalent full-range temperature coefficient of 50ppm/ °C
typical for operation over full rated operating temperature
range. SOP-8 1: Cathode 2,3,6,7: Anode 8: Ref.
4,5: N.C.
TO-92 1: Ref ; 2: Anode; 3: Cathode
SOT-89 1: Ref ; 2: Anode; 3: Cathode
SOT-23 1: Cathode; 2: Ref; 3: Anode
BLOCK DIAGRAM
CATHODE
REFERENCE
CATHODE
(K)
REFERENCE
(R)
ANODE(A)
2.5V Vref
ANODE
Fig 1 Cathode Current Vs Cathode Voltage Fig 2 Cathode Current Vs Cathode Voltage
800
Ta=25℃ Ta=25℃
125
VKA=VREF VKA=VREF
100 600
Cathode Current (mA)
50 400
IKA(min)
25
0 200
-25
-50 0
-75
-100 -200
-2 -1 0 1 2 3 -2 -1 0 1 2 3
Cathode Voltage (V) Cathode Voltage (V)
Ta=25℃
-5 7
IKA=100mA
Input and Output Voltage (V)
Change In Reference INput
Ta=25℃
-10 6
-15 5
Voltage (mV)
-20 4
-25 3
-30 2
-35 1
-40 0
0 5 10 15 20 25 30 35 40 0 1 2 3 4 5 6 7
Cathode Voltage (V) Time (µ s)
1
10 40
30
0
20
10
10
-1
10 -10
3 4 5 6 7 3 4 5 6 7
10 10 10 10 10 10 10 10 10 10
Frequency (Hz)
Frequency (Hz)
R1
IREF
UTC TL431A UTC TL431A UTC TL431A
VREF R2 VREF
VKA= VREF*(1+R1/R2)+IREF*R1
Fig 7 Test Circuit For VKA=VREF Fig 8 Test Circuit for VKA >= VREF Fig 9 Test Circuit For IKA(OFF)
APPLICATION CIRCUIT
Vi Vo
Vi Vo IN
Vi OUT
Vo
UTC7805
COMMON
R1 R1 R1
Fig 10 Shutdown Regulator Fig 11 Output Control of a Three Fig 12 Higher-current Shunt Regulator
-Terminal Fixed Regulator
Io Vo
Vi Vi
Io Vo
RCL
Rs
Rs UTC TL431A
IO=VREF/RS RS=VREF/RCL
UTC TL431A
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.