Three Phase With Neutral Thyristor Power Controllers

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Dydac offers wide range of Digital Thyristor ( SCR ) Power Controllers in

THREE PHASE STAR WITH NEUTRAL


FEATURES
1. Soft start – bake out feature prevents moisture at start up
2. Current Limit , Phase Loss Trip, Over temperature Trip
3 Microprocessor Digital Programmable Thyristor Power Controller with Percentage
Display. Program setting of Current Limit, Soft start etc by front keys
RATINGS

1. Three Phase Star with Neutral - 35, 50, 70, 90, 150, 200,
250, 300, 350, 400 Amperes .
Dydac Controls Thyristor SCR Power Controllers |some
typical applications:
 Large tank heating and mechanical relay replacement.
 Thermoforming, textiles, industrial furnaces and ovens, extruders,
kilns, chemical process heating, fast water heat.
 Paper and pulp drying, packaging machines, pharmaceutical processes,
infrared ovens and dryers.
 High-temperature ovens and furnaces, kilns, glass, ceramics & high-
temperature alloys.
 High-speed paper and ink dryers, high temperature IR heating, high
temperature materials processing.
 Primary of transformer-coupled loads.
 Phase angle proportional control. No temperature or power cycling
 I2T Rectifier fuses standard
 Isolated SCR's
 Integrated thermal/mechanical design saves panel space
 Voltage protection - MOV capacitance
 10 to 400 Ampere current ratings. Other Ratings Over 400 Amps
Possible.
 Easy to install, test, service
The Dydac Thyristor Power Controller is a heavy duty, fully Digital or Analog three
phase power control unit for controlling the voltage applied to loads such as heating
elements, thus, allowing temperature control while eliminating contactor switching and
over/under heating.
The first in a series of Digital or Analog Thyristor ( SCR ) Power Controllers
incorporating protection functions.
Built in switching methods are:
1. Phase Control Firing
Range: 15 A - 400 A , 220-1200V,

Advantages at a glance
* Fully digital Thyristor
* Analog Thyristor
* Phase Control and Zero Crossing
* Current: 15 – 400 A (consult us when higher ratings are needed)
* Voltage: 230- 500 V 50/60Hz
* Cooling Method: Forced air
* Ambient. Temp: 0 - 50°C
* Continuous Duty
* One, Two or Three controlled phases
* C.T.'s
* Input, 4-20mA or 0-20mA, 0-10VDC
* Digital display
LEDs
* PLT * Over Current
* Over Temperature * Alarm * Trip
Connection types
* Three Phase Star with Neutral
Protection functions
* Under & Over current
* Phase loss * Shorted SCR
* Heat sink over temperature Trip & Alarm
* Internal failure
The SCR control can deliver electrical power to heaters in several ways: phase angle
fired, zero voltage switched and on/off control.

RATING AND MODEL


No Model Specifications Max. Load
Current

1. TPR3000 – 415 +N – 30 A Input Signal ( 4-20 mA ) 415 VAC Input / 415 VAC+ 30 Amps
NEUTRAL DIRECT Output
2 TPR3000 – 415 + N– 65 A Input Signal ( 4-20 mA ) 415 VAC Input / 415 VAC + 65 Amps
NEUTRAL DIRECT Output
3. TPR 3000– 415 +N– 80 A Input Signal ( 4-20 mA ) 415 VAC Input / 415 VAC + 80 Amps
NEUTRAL DIRECT Output
4. TPR 3000– 415 +N– 130 A Input Signal ( 4-20 mA ) 415 VAC Input / 415 VAC + 130 Amps
NEUTRAL DIRECT Output
5. TPR3000 – 415 +N– 200 A Input Signal ( 4-20 mA ) 415 VAC Input / 415 VAC + 200 Amps
NEUTRAL DIRECT Output
6. TPR3000 –415+N – 240 A Input Signal ( 4-20 mA ) 415 VAC Input / 415 VAC + 240 Amps
NEUTRAL DIRECT Output
7. TPR3000 – 415 +N– 300 A Input Signal ( 4-20 mA ) 415 VAC Input / 415 VAC + 300 Amps
NEUTRAL DIRECT Output
8. TPR3000 – 415+N – 400 A Input Signal ( 4-20 mA ) 415 VAC Input / 415 VAC + 400 Amps
NEUTRAL DIRECT Output

Product can be changed or modified without Notice


TYPES OF LOADS
Heater/Load Heater/Load Typical
Control Type
Type Characteristics Applications
Constant Resistance Slow Response On/Off Large tank heating and
Elements. Immersion Zero Voltage mechanical relay replacement.
heaters. Switched / Phase
Angle Fired
Medium wave infrared, Faster response, Phase Angle Fired Thermoforming, textiles,
ceramic, cartridge, Constant resistance or Zero Voltage industrial furnaces and ovens,
duct, strip, and band heaters only. Switched extruders, kilns, chemical process
heaters. Platens. heating, fast water heat.
Open coil/wire Fastest, most precise Phase Angle Fired Paper and pulp drying, packaging
heaters. Medium wave response. machines, pharmaceutical
IR quartz. IR panels. processes, infrared ovens &
dryers.
Silicon Carbide Load changes in Phase Angle Fired High temperature ovens and
heaters. resistance with age. with Current Limit furnaces, glass, ceramics and
High temperature Option high temperature alloys.
elements.
Tungsten (T-3) lamps High inrush currents Phase Angle Fired High speed paper and ink dryers,
and heaters. Short High hot: cold with Soft Start high temperature IR heating, high
wave IR elements. resistance ration option temperature materials
Molybdenum heaters. Tungsten 14:1 processing.
Molybdenum 20:1
Graphite: 20:1
Transformer coupled Inductive loads. Phase Angle Fired Used with transformer-coupled
loads. Primary driving. with Soft Start heater loads to drive low voltage
Inductive heater loads. option. Current elements.
limit option.

You might also like