Advantage

andAdvantage+
Cast Iron
Standard Efficiency and Premium Efficiency
Totally Enclosed Fan Cooled
Cage Induction Motors
Advantage
Teco’s range of cast iron motors are divided Bearings
into normal performance, standard efficiency Motors <frame size D160 are double shielded,
and high performance premium efficiency greased for life, >frame size D160 have a full
ranges. pressure grease relief system

The TECO Advantage standard efficiency Nameplate


range complies with CEMEP/EC efficiency All nameplates are stainless steel
class EFF2.
Overload protection
The TECO Advantage+ Premium efficiency All motors> frame size D160 are fitted with 3 x
range complies with class EFF1 and the U.K. thermistors (1/phase)
government criteria for eligibility for the en-
hanced capital allowance scheme. Paint
High build primer and topcoat of 50 microns
These TEFC cage induction motors are de- dry film thickness. Colour, grey, to Munsell
signed, manufactured and tested to meet the 7.5BG4/2.
latest international standards.
Options
The high quality and rugged cast iron The following additional options are available
construction, backed by a three year on request:-
warranty makes them ideal for all industrial
applications. · Protection, IP56, IP65 enclosures
· Anti condensation heaters
Advantage

Ratings & Standards · Tropic proofing


All motors comply with the relevant parts of · Special paint finishes
BSEN60034, IEC60034 and IEC60072 · Pad mounting

Advantage
· Mechanical brakes
Electrical Supply · Smoke extraction motors – high
Standard voltage at 50Hz temperature
<2.2kW 230V delta, 400V star · Special shaft extensions
>3kW 400V delta
Other non standard voltages can be supplied
on request

Enclosure
Totally enclosed fan cooled (TEFC). Weather
protected IP55

Insulation
Class F insulation with Class B (80oC)
temperature rise based on ambient
temperature <40oC _+ altitude <1000m
above sea level

Construction
Frames, endshields and terminal box
assembly – high grade cast iron
Fan – bi directional propylene
Fan cover – heavy gauge steel

CAST IRON
Rotor – pressure die cast aluminium

2
performance data EFF2*
0.18kW - 18.5kW TEFC, Class F, S1 (MCR) Duty

F u ll C u rre n t E F F IC IE N C Y P O W E R F A C T O R D .O .L . D .O .L . P u ll P u ll R o to r
L o a d a t 1 0 0 % 7 5 % 1 0 0 % 7 5 % S ta r t S ta r t U p O u t In e r t i a
S p e e d F ra m e 4 0 0 V L O A D L O A D L O A D L O A D C u rre n t T o rq u e T o rq u e T o rq u e G .D 2
k W
(R P M ) N o . (A m p s ) (% ) (% ) C o s Ø C o s Ø (% F L T ) (% F L T ) (% F L T ) (% F L T ) k g .m 2
0 .1 8 1 3 2 0 D 6 3 0 .5 5 6 7 .7 6 7 .6 6 9 .7 0 6 0 .0 0 3 3 9 2 7 2 2 6 5 2 6 6 0 .0 0 3 1
9 1 6 D 7 1 0 .6 4 6 4 .5 6 1 .4 6 2 .6 0 5 2 .8 0 2 8 6 .0 3 0 4 2 9 6 3 1 7 0 .0 0 5 9
7 0 4 D 8 0 1 1 5 2 .8 4 7 .9 4 5 .9 4 0 .6 1 6 4 3 9 3 3 8 0 3 9 5 0 .0 1 1 8
0 .3 7 2 7 9 6 D 7 1 0 .8 1 7 7 .3 7 6 .2 8 5 .0 0 7 7 .3 0 6 0 2 3 1 1 3 1 7 3 2 3 0 .0 0 2 5
1 3 7 0 D 7 1 1 .1 7 0 .3 6 8 .4 6 8 .3 0 5 8 .7 0 4 3 5 2 7 6 2 7 2 2 9 6 0 .0 0 5
9 1 9 D 8 0 1 .1 6 9 .0 6 7 .4 6 8 .2 5 8 .5 3 3 9 2 4 1 2 3 7 2 5 8 0 .0 0 9
7 0 7 D 9 0 S 1 .2 7 0 .8 6 8 .5 6 0 .5 5 1 .5 3 8 8 2 1 9 2 2 0 2 6 4 0 .0 1 7 8
0 .5 5 2 7 8 7 D 7 1 1 .3 7 5 .5 7 4 .5 8 2 .3 7 4 .1 5 3 4 3 1 4 2 6 3 3 1 6 0 .0 0 2 5
1 4 0 8 D 8 0 1 .4 7 5 .3 7 4 .0 7 5 .5 6 6 .0 4 8 6 2 6 9 2 5 9 2 9 5 0 .0 0 7 4
8 9 3 D 8 0 1 .6 7 0 .2 7 0 .3 7 2 .9 6 3 .2 3 7 0 2 3 3 2 3 2 2 2 6 0 .0 1 1 8
6 8 8 D 9 0 S 1 .6 7 2 .6 7 2 .8 6 9 .9 6 1 .1 3 7 0 1 8 3 1 5 1 2 0 5 0 .0 2 3 5
0 .7 5 2 8 0 2 D 8 0 1 .6 8 0 .5 8 1 .0 8 6 .6 8 0 .7 5 8 0 2 9 0 2 8 0 3 1 9 0 .0 0 5
1 3 9 0 D 8 0 1 .9 7 6 .0 7 5 .4 7 6 .7 6 6 .7 4 8 1 2 8 0 2 5 9 2 8 8 0 .0 0 9
9 4 2 D 9 0 S 2 .0 7 7 .1 7 6 .1 7 1 .4 6 2 .1 4 5 7 2 0 6 2 0 0 2 5 0 0 .0 1 8
7 0 0 D 1 0 0 L 2 .3 7 2 .5 7 1 .4 6 5 .1 5 6 .7 3 8 6 1 8 7 1 6 3 2 2 5 0 .0 3 5
1 .1 2 8 0 8 D 8 0 2 .2 8 1 .5 8 2 .0 8 7 .7 8 2 .4 6 2 2 3 1 7 2 9 7 3 2 0 0 .0 0 6
1 4 0 9 D 9 0 S 2 .6 7 8 .6 7 8 .4 7 8 .0 6 9 .9 4 9 2 2 2 6 1 9 9 2 5 3 0 .0 1 4
9 3 7 D 9 0 L 3 .0 7 7 .8 7 7 .1 6 8 .8 5 9 .8 4 6 2 2 4 7 2 0 5 2 8 5 0 .0 2 4
6 9 4 D 1 0 0 L 3 .1 7 6 .3 7 6 .1 6 6 .3 5 8 .0 4 0 4 2 1 7 2 0 8 2 3 5 0 .0 4 5
1 .5 2 7 7 9 D 9 0 S 3 .0 8 2 .0 8 3 .0 8 7 .2 8 2 .6 5 6 7 3 1 0 2 5 5 2 8 8 0 .1 1
1 4 0 5 D 9 0 L 3 .3 7 9 .6 7 9 .8 8 1 .4 7 3 .9 5 4 5 2 3 5 2 1 1 2 7 4 0 .0 1 8
9 1 8 D 1 0 0 L 3 .8 7 5 .6 7 6 .7 7 6 .1 6 8 .8 4 5 0 2 1 2 2 0 3 2 3 3 0 .0 3 3
7 0 3 D 1 1 2 M 4 .3 7 4 .7 7 3 .8 6 6 .9 5 8 .0 4 1 3 1 7 8 1 5 3 2 3 6 0 .0 6
2 .2 2 8 3 9 D 9 0 L 4 .2 8 5 .0 8 5 .6 8 9 .1 8 5 .5 7 1 1 2 6 0 2 4 7 3 1 4 0 .0 1 5
1 4 2 9 D 1 0 0 L 4 .7 8 3 .2 8 3 .3 8 1 .9 7 5 .3 6 3 8 2 5 9 2 3 8 2 4 6 0 .0 3 3

Advantage
9 4 4 D 1 1 2 M 5 .1 8 1 .8 8 1 .8 7 6 .7 6 8 .5 5 4 7 2 1 6 1 9 0 2 7 1 0 .0 6
6 9 8 D 1 3 2 S 5 .1 8 2 .2 8 3 .1 7 6 .0 6 8 .4 4 4 8 2 1 5 1 9 9 2 5 5 0 .1 5 4
3 2 8 4 8 D 1 0 0 L 5 .5 8 6 .4 8 6 .8 9 0 .4 8 6 .9 6 9 9 3 3 6 3 2 3 3 5 4 0 .0 2 3
1 4 2 8 D 1 0 0 L 6 .2 8 4 .4 8 4 .2 8 3 .1 7 6 .0 6 5 8 3 4 2 3 0 4 3 6 5 0 .0 4 7
9 5 6 D 1 3 2 S 6 .3 8 6 .1 8 6 .5 8 0 .0 7 4 .0 5 6 7 1 9 5 1 7 1 2 4 5 0 .1 5 4
7 1 7 D 1 3 2 M 7 .5 8 4 .1 8 3 .7 6 8 .2 5 9 .2 5 1 1 2 6 4 2 4 7 3 2 5 0 .1 9 2
4 2 8 6 8 D 1 1 2 M 7 .2 8 7 .3 8 7 .6 9 2 .2 8 9 .4 7 7 1 3 2 2 3 0 8 3 3 9 0 .0 4 7
1 4 4 3 D 1 1 2 M 8 .2 8 6 .4 8 6 .4 8 1 .9 7 6 .0 6 8 0 2 5 4 2 4 5 3 4 2 0 .0 6 6
9 5 8 D 1 3 2 M 8 .8 8 4 .2 8 3 .9 7 7 .7 7 0 .9 5 8 0 2 2 3 2 0 9 2 5 0 0 .1 8 1
7 2 3 D 1 6 0 M 8 .9 8 5 .9 8 5 .7 7 5 .5 6 7 .9 5 3 2 1 9 8 1 8 8 2 8 3 0 .3 5 1
5 .5 2 9 1 0 D 1 3 2 S 1 0 .5 8 6 .7 8 6 .4 8 9 .7 8 6 .0 8 7 0 2 4 0 2 1 6 3 7 7 0 .0 1 0 4
1 4 4 5 D 1 3 2 S 1 1 8 5 .7 8 5 .3 8 4 .9 7 7 .6 7 3 5 2 2 3 2 0 0 3 2 0 0 .0 2 0 5
9 6 0 D 1 3 2 M 1 2 8 5 .5 8 5 .2 7 7 .2 6 8 .4 7 3 1 2 1 1 1 8 9 4 1 3 0 .0 4 3 1
7 2 0 D 1 6 0 M 1 2 .9 8 4 .5 8 4 .9 7 5 .5 6 8 .2 5 7 5 2 1 7 1 9 5 3 3 1 0 .0 8 2 1
7 .5 2 9 0 5 D 1 3 2 S 1 4 .3 8 7 .3 8 8 .0 8 9 .8 8 6 .8 6 6 5 2 1 6 1 9 4 3 5 5 0 .0 1 2 1
1 4 4 5 D 1 3 2 M 1 5 8 7 .5 8 7 .9 8 5 .5 8 0 .8 7 7 6 2 6 3 2 3 6 3 4 9 0 .0 2 9 8
9 7 0 D 1 6 0 M 1 6 8 5 .3 8 5 .1 7 9 .7 7 4 .0 6 4 6 1 8 7 1 6 8 3 4 9 0 .0 8
7 2 0 D 1 6 0 L 1 7 8 6 .1 8 6 .9 7 7 .3 7 0 .3 5 7 6 2 1 6 1 9 4 3 4 0 0 .1 1 4 1
1 1 2 9 3 5 D 1 6 0 M 2 0 8 7 .2 8 6 .8 8 9 .6 8 7 .4 7 8 4 2 5 7 2 3 1 3 2 6 0 .0 3 7
1 4 6 0 D 1 6 0 M 2 2 8 8 .0 8 8 .2 8 5 .0 7 9 .7 7 9 2 2 4 2 2 1 7 3 1 3 0 .0 7 2 4
9 7 0 D 1 6 0 L 2 3 8 7 .8 8 8 .0 8 1 .4 7 5 .4 6 9 6 1 9 5 1 7 5 3 3 3 0 .0 1 0 8
7 3 0 D 1 8 0 L 2 4 8 7 .5 8 7 .8 7 7 .4 7 0 .2 6 5 7 2 3 0 2 0 7 2 9 7 0 .1 6 7
1 5 2 9 3 5 D 1 6 0 M 2 7 8 9 .4 8 8 .9 9 0 .7 8 8 .7 7 7 7 2 4 3 2 1 8 3 2 7 0 .0 4 3 2
1 4 6 0 D 1 6 0 L 2 8 8 9 .4 8 9 .4 8 5 .3 8 0 .6 8 1 5 3 0 0 2 7 0 3 3 3 0 .0 9 2 1
9 7 0 D 1 8 0 L 2 9 8 9 .5 8 9 .8 8 2 .7 7 7 .9 6 4 0 2 1 3 1 9 1 3 0 3 0 .1 6 7
7 3 0 D 2 0 0 L 3 2 8 9 .1 8 9 .2 7 7 .8 7 1 .2 6 2 5 1 8 6 1 6 7 2 9 8 0 .3 2 5
1 8 .5 2 9 3 5 D 1 6 0 L 3 3 9 0 .1 9 0 .2 9 1 .8 8 9 .9 7 9 3 2 7 5 2 4 7 3 3 6 0 .0 5 2 5
1 4 7 0 D 1 8 0 M 3 4 9 0 .5 9 0 .7 8 9 .1 8 4 .7 7 5 7 2 4 5 2 2 0 3 1 5 0 .1 3 5
9 7 5 D 2 0 0 L 3 6 8 9 .9 9 0 .1 8 4 .0 7 8 .7 6 5 1 2 1 3 1 9 1 3 2 9 0 .3 0 2
7 3 0 D 2 2 5 S 3 8 9 0 .1 9 0 .2 7 7 .0 7 1 .0 6 8 0 2 0 0 1 8 0 3 0 0 0 .4 8 1

Note:
1. All figures are based on full load tests carried out on 400 Volt 3 Phase 50Hz motors.
2. Test method: EN60034 Part 2.
3. Tolerance: EN60034 Part 1.
4. All data is subject to change without prior notification. Not to be used for installation
purposes without referring to TECO Electric Europe Limited.
5. *EFF2 applies to the motor range 1.1kW - 90kW, 2 and 4 pole.

standardefficiency 3
performance data EFF2*
22kW - 315kW TEFC, Class F, S1 (MCR) Duty

F u ll C urrent E F F IC IE N C Y PO W ER FAC TO R D .O .L . D .O .L . P u ll P u ll R o to r
Load at 100% 75% 100% 75% S ta r t S ta r t U p O ut In e r t i a
Speed F ram e 400V LO AD LO AD LO AD LO AD C urrent T o rq ue T o rq ue T o rq u e G .D 2
kW
(R P M ) N o. (A m p s ) (% ) (% ) C os Ø C os Ø (% F L T ) (% F L T ) (% F L T ) (% F L T ) k g .m 2
22 2940 D 180M 39 9 0 .8 9 0 .6 9 0 .7 8 8 .9 752 252 226 344 0 .0 7 1
1470 D 180L 40 9 1 .3 9 1 .8 8 8 .1 8 4 .2 674 225 202 309 .0 1 3 6
975 D 200L 42 8 9 .9 9 0 .3 8 4 .7 8 1 .1 669 217 195 316 0 .3 4 7
730 D 225M 44 9 0 .6 9 0 .7 7 7 .0 7 2 .2 682 213 191 301 0 .5 3 1
30 2945 D 200L 53 9 1 .6 9 1 .3 9 0 .0 8 7 .9 742 266 239 346 0 .1 1 9
1470 D 200L 55 9 1 .9 9 2 .1 8 8 .5 8 3 .4 664 231 207 303 0 .2 4 5
980 D 225M 55 9 1 .7 9 1 .8 8 5 .2 8 2 .6 612 235 211 284 0 .5 2 5
730 D 250M 60 9 0 .8 9 0 .8 8 2 .3 7 6 .8 582 198 178 298 0 .8 0 9
37 2945 D 200L 64 9 2 .0 9 1 .3 9 2 .0 8 9 .8 782 248 223 298 0 .8 0 9
1475 D 225S 66 9 2 .4 9 2 .5 8 7 .5 8 4 .9 658 221 198 306 0 .3 9
980 D 250M 68 9 1 .5 9 1 .4 8 6 .8 8 3 .1 688 212 190 323 0 .8 0 7
735 D 280S 74 9 1 .5 9 1 .5 7 9 .0 7 1 .0 660 200 180 240 1 .3 8 1
45 2950 D 225M 77 9 2 .5 9 2 .4 8 9 .8 8 7 .8 788 275 247 369 0 .2 2 1
1475 D 225M 80 9 2 .5 9 2 .5 8 8 .8 8 6 .2 743 209 188 314 0 .4 5
980 D 280S 82 9 2 .5 9 2 .3 8 6 .0 8 3 .0 700 230 207 270 1 .3 3 4
735 D 280M 90 9 2 .0 9 1 .8 7 9 .0 7 1 .0 660 200 180 240 1 .7 2 1
55 2965 D 250M 95 9 3 .0 9 2 .1 8 9 .2 8 6 .3 770 195 175 368 0 .3 0 5
1475 D 250M 98 9 3 .0 9 2 .8 8 8 .9 8 6 .0 685 223 200 316 0 .6 4
980 D 280M 100 9 2 .8 9 2 .5 8 6 .0 8 3 .0 700 230 207 270 1 .5 9 8
735 D 315S 110 9 2 .8 9 2 .7 8 1 .0 7 1 .0 660 180 160 220 4 .5 9
75 2965 D 280S 127 9 3 .6 9 3 .0 9 1 .0 8 9 .0 780 220 200 250 0 .5 8 4
1485 D 280S 133 9 3 .8 9 3 .5 8 7 .0 8 5 .0 750 220 200 240 1 .0 4 5
Advantage

935 D 315S 135 9 3 .5 9 3 .2 8 6 .0 8 3 .0 700 200 180 240 3 .9 4


735 D 315M 145 9 3 .0 9 2 .8 8 1 .0 7 2 .0 660 180 160 220 5 .3 6
90 2965 D 280M 152 9 3 .9 9 3 .3 9 1 .0 8 9 .0 780 220 200 250 0 .6 6 5
1485 D 280M 159 9 4 .2 9 3 .9 8 7 .0 8 5 .0 750 220 200 240 1 .3 9 6
935 D 315M 160 9 3 .8 9 3 .5 8 6 .0 8 3 .0 700 200 180 240 4 .5 8
735 D 315L 170 9 3 .8 9 3 .5 8 2 .0 7 2 .0 660 180 160 230 6 .1 1
110 2975 D 315S 186 9 4 .0 9 3 .5 9 1 .0 8 9 .0 710 180 160 240 1 .1 3
1485 D 315S 191 9 4 .5 9 4 .2 8 8 .0 8 5 .0 690 220 200 270 2 .9 8
935 D 315L 197 9 4 .0 9 3 .7 8 6 .0 8 3 .0 700 210 190 240 5 .2 3
735 D 315L 205 9 4 .0 9 3 .8 8 2 .0 7 2 .0 660 190 170 230 6 .5 5
132 2975 D 315M 222 9 4 .5 9 4 .0 9 1 .0 8 9 .0 710 180 160 240 1 .7 5
1485 D 315M 229 9 4 .8 9 4 .5 8 8 .0 8 6 .0 690 220 200 260 3 .4 8
935 D 315L 233 9 4 .2 9 3 .9 8 7 .0 8 3 .0 700 210 190 230 5 .5 4
745 D 355M 250 9 3 .5 9 3 .2 8 2 .0 7 3 .0 650 190 170 200 1 0 .4 0
160 2975 D 315L 266 9 4 .6 9 4 .1 9 2 .0 8 9 .0 710 180 160 250 2 .0 1
1485 D 315L 273 9 4 .9 9 4 .6 8 9 .0 8 6 .0 690 220 200 240 3 .9 6
990 D 355M 277 9 4 .8 9 4 .5 8 8 .0 8 4 .0 700 200 180 200 8 .8 1
745 D 355M 300 9 3 .5 9 3 .2 8 3 .0 7 3 .0 650 190 170 200 1 1 .7
200 2975 D 315L 331 9 4 .8 9 4 .3 9 2 .0 8 9 .0 710 180 160 250 2 .2 7
1485 D 315L 342 9 5 .0 9 4 .7 8 9 .0 8 6 .0 690 220 200 240 4 .4 7
990 D 355M 345 9 5 .0 9 4 .5 8 8 .0 8 4 .0 700 200 180 200 9 .6 3
745 D 315L 367 9 4 .8 9 4 .5 8 3 .0 7 4 .0 650 190 170 200 1 2 .8
250 2970 D 355M 410 9 5 .5 9 5 .0 9 2 .0 9 0 .0 730 160 145 220 2 .9 7
1490 D 355M 415 9 5 .5 9 5 .2 9 1 .0 0 .8 7 680 230 210 230 5 .7 5
990 D 355L 425 9 5 .0 9 4 .5 8 9 .0 8 4 .0 700 230 210 250 1 0 .5 4
315 2970 D 355L 515 9 5 .8 9 5 .3 9 2 .0 9 0 .0 730 160 145 220 4 .1 7
1490 D 355L 520 9 5 .8 9 5 .5 9 1 .0 0 .8 8 680 230 210 230 5 .7 9

Note:
1. All figures are based on full load tests carried out on 400 Volt 3 Phase 50Hz motors.
2. Test method: EN60034 Part 2.
3. Tolerance: EN60034 Part 1.
4. All data is subject to change without prior notification. Not to be used for installation
purposes without referring to TECO Electric Europe Limited.

standardefficiency
5. *EFF2 applies to the motor range 1.1kW - 90kW, 2 and 4 pole.

4
dimensions foot
frames 63 - D112M mounted

Fig 1 Fig 2
dimensions in mm

B3
Output (kW) Fig
Frame No.
2P 4P 6P 8P No. A AB AC AD B C D E F G H

0.185 0.185 - - D63 1 100 120 144 135 80 40 11 23 4 8.5 63

0.37/0.55 0.37 0.185 - D71 1 112 140 162 145 90 45 14 30 5 11 71

0.75/1.1 0.55/0.75 0.37/0.55 0.185 D80 1 125 155 177 178 100 50 19 40 6 15.5 80

Advantage
1.5 1.1 0.75 0.37 D90S 1 140 170 200 189 100 56 24 50 8 20 90

2.2 1.5 1.1 0.55 D90L 1 140 170 200 189 125 56 24 50 8 20 90

3 2.2/3 1.5 0.75/1.1 D100L 2 160 195 219 199 140 63 28 60 8 24 100

4 4 2.2 1.5 D112M 2 190 224 238 208 140 70 28 60 8 24 112

Frame Fig. Bearings Approx.Wt.

No. No. HD K KK L Drive end Non-Drive end (kg)

D63 1 - 7 M20x1.5 209 *6201ZZ *6201ZZ 8.2

D71 1 - 7 M20x1.5 239 *6202ZZ *6202ZZ 11

D80 1 - 10 M25x1.5 272 *6204ZZ *6204ZZ 15

D90S 1 - 10 M25x1.5 297 *6205ZZ *6205ZZ 20

D90L 1 - 10 M25x1.5 322 *6205ZZ *6205ZZ 22

D100L 2 243 12 M25x1.5 363 *6206ZZ *6305ZZ 30

D112M 2 265 12 M25x1.5 382 *6306ZZ *6306ZZ 42

Note:
1. Tolerance of Shaft End Diameter D: Under Ø28:j6.
2. Tolerance of Shaft Centre Height H: +0, -0.5.
3. Bearing with mark*: Grease Packed Shielded Rolling Bearings.
4. All data is subject to change without prior notification. Not to be used for
installation purposes without referring to TECO Electric Europe Limited.

standardefficiency 5
dimensions foot
frames 132S - 355L mounted

D132 - D355 D132 - D355


dimensions in mm
O u tp u t (k W )
F ra m e N o .
2P 4P 6P 8P A AB AC AD B C D E F G H

5 . 5 /7 .5 5 .5 3 2 .2 D132S 216 270 275 210 140 89 38 80 10 33 132

B3
- 7 .5 4 /5 .5 3 D 132M 216 270 275 210 178 89 38 80 10 33 132

1 1 /1 5 11 7 .5 4 /5 .5 D 160M 254 320 330 255 210 108 42 110 12 37 160

1 8 .5 15 11 7 .5 D160L 254 320 330 255 254 108 42 110 12 37 160

22 1 8 .5 - - D 180M 279 355 380 280 241 121 48 110 14 4 2 .5 180

- 22 15 11 D180L 279 355 380 280 279 121 48 110 14 4 2 .5 180

3 0 /3 7 30 1 8 . 5 /2 2 15 D200L 318 395 420 305 305 133 55 110 16 49 200

- 37 - 1 8 .5 D225S 356 435 470 335 286 149 60 140 18 53 225

45 356 435 470 335 311 149 55 110 16 49 225


D 225M
45 30 22 356 435 470 335 311 149 60 140 18 53 225

55 406 490 510 370 349 168 60 140 18 53 250


D 250M
55 37 30 406 490 510 370 349 168 65 140 18 58 250

75 457 550 580 410 368 190 65 140 18 58 280


D280S
75 45 37 457 550 580 410 368 190 75 140 20 6 7 .5 280

90 457 550 580 410 419 190 65 140 18 58 280


Advantage

D 280M
90 55 45 457 550 580 410 419 190 75 140 20 6 7 .5 280

110 508 635 645 530 406 216 65 140 18 58 315


D315S
110 75 55 508 635 645 530 406 216 80 170 22 71 315

132 508 635 645 530 457 216 65 140 18 58 315


D 315M
132 90 75 508 635 645 530 457 216 80 170 22 71 315

1 6 0 /2 0 0 508 635 645 530 508 216 65 140 18 58 315


D315L
1 6 0 /2 0 0 1 1 0 /1 3 2 9 0 /1 1 0 508 635 645 530 508 216 80 170 22 71 315

250 610 730 710 655 560 254 75 140 20 6 7 .5 355


D 355M
250 1 6 0 /2 0 0 1 3 2 /1 6 0 610 730 710 655 560 254 95 170 25 86 355

315 610 730 710 655 630 254 75 140 20 6 7 .5 355


D355L
315 250 200 610 730 710 655 630 254 95 170 25 86 355

F ra m e L B e a r in g s A p p r o x .W t.

N o. HD K KK 2 P / 4 ,6 ,8 P D r iv e e n d N o n -D r iv e e n d (k g )

D132S 345 12 1 -M 2 5 x 1 .5 470 6 3 0 8 Z Z -C 3 * 6 3 0 8 Z Z -C 3 * 60

D132M 345 12 1 -M 2 5 x 1 .5 510 6 3 0 8 Z Z -C 3 * 6 3 0 8 Z Z -C 3 * 67

D160M 420 15 2 -M 3 2 x 1 .5 615 6 3 0 9 Z Z -C 3 * 6 3 0 9 Z Z -C 3 * 107

D160L 420 15 2 -M 3 2 x 1 .5 670 6 3 0 9 Z Z -C 3 * 6 3 0 9 Z Z -C 3 * 131

D180M 455 15 2 -M 3 2 x 1 .5 700 6 3 1 1 -C 3 6311C 3 130

D180L 455 15 2 -M 3 2 x 1 .5 740 6 3 1 1 -C 3 6311C 3 174

D200L 545 19 2 -M 5 0 x 1 .5 770 6 3 1 2 -C 3 6 3 1 2 -C 3 225

D225S 555 19 2 -M 5 0 x 1 .5 815 6 3 1 3 -C 3 6 3 1 3 -C 3 278

D225M 555 19 2 -M 5 0 x 1 .5 8 2 0 /8 4 5 6 3 1 3 -C 3 6 3 1 3 -C 3 300

D250M 615 24 2 -M 6 3 x 1 .5 9 1 0 /9 1 0 6 3 1 4 -C 3 6 3 1 4 -C 3 379

D280S 680 24 2 -M 6 3 x 1 .5 9 8 5 /9 8 5 6 3 1 4 -C 3 * / 6 3 1 7 -C 3 * * 6 3 1 4 -C 3 * / 6 3 1 7 -C 3 * * 490

D280M 680 24 2 -M 6 3 x 1 .5 1035 6 3 1 4 -C 3 * / 6 3 1 7 -C 3 * * 6 3 1 4 -C 3 * / 6 3 1 7 -C 3 * * 558

D315S 845 28 2 -M 6 3 x 1 .5 1 1 6 0 /1 2 7 0 6 3 1 7 -C 3 * / N 3 1 9 6 3 1 7 -C 3 / 6 3 1 9 -C 3 * * 904

D315M 845 28 2 -M 6 3 x 1 .5 1 1 9 0 /1 3 0 0 6 3 1 7 -C 3 * / N 3 1 9 6 3 1 7 -C 3 / 6 3 1 9 -C 3 * * 975

D315L 845 28 2 -M 6 3 x 1 .5 1 1 9 0 /1 3 0 0 6 3 1 7 -C 3 * / N 3 1 9 6 3 1 7 -C 3 / 6 3 1 9 -C 3 * * 1125

D355M 1010 28 2 -M 7 5 x 1 .5 1 5 0 0 /1 5 3 0 6 3 1 9 -C 3 * / N 3 2 2 * * 6 3 1 9 -C 3 * / 6 3 2 0 -C 3 * * 1698

D355L 1010 28 2 -M 7 5 x 1 .5 1 5 0 0 /1 5 3 0 6 3 1 9 -C 3 * / N 3 2 2 * * 6 3 1 9 -C 3 * / 6 3 2 0 -C 3 * * 1880

N .B . * 2 p o le / * * 4 ,6 ,8 p o le

Note:
1. Tolerance of Shaft End Diameter D: Ø38 to Ø48:k6, Ø55 and above:m6.
2. Tolerance of Shaft Centre Height H: 250 and below: +0, -0.5; 280 and above: +0, -1.
3. Bearing with mark*: Grease Packed Shielded Rolling Bearings.
4. All data is subject to change without prior notification. Not to be used for
installation purposes without referring to TECO Electric Europe Limited.

standardefficiency 6
dimensions flange
frames 63 - 112M mounted

dimensions in mm

V1/B5
Fig 1 Fig 2 Fig 3

Advantage
Output (kW) Frame Fig

2P 4P 6P 8P No. No. AC D E F G KK L

0.2 0.185 - - D63D 1 144 11 23 4 8.5 M20x1.5 238

0.37/0.55 0.37 0.185 - D71D 1 162 14 30 5 11 M20x1.5 266

0.75/1.1 0.55 0.37/0.5 0.185 D80D 2 177 19 40 6 15.5 M25x1.5 272

1.5 1.1 0.75 0.37 D90SD 3 200 24 50 8 20 M25x1.5 336

2.2 1.5 1.1 0.55 D90LD 3 200 24 50 8 20 M25x1.5 361

3 2.2/3 1.5 0.75/1.1 D100LD 2 219 28 60 8 24 M25x1.5 363

4 4 2.2 1.5 D112MD 3 238 28 60 8 24 M25x1.5 422

Frame Fig. Bearings Approx.Wt.

No. No. M N P S T Drive End Non-Drive End (kg)

D63D 1 115 95 140 10 3 *6201ZZ *6201ZZ 9.2

D71D 1 130 110 160 10 3.5 *6202ZZ *6202ZZ 12

D80D 2 165 130 200 12 3.5 *6204ZZ *6204ZZ 17

D90SD 3 165 130 200 12 3.5 *6205ZZ *6205ZZ 22.8

D90LD 3 165 130 200 12 3.5 *6205ZZ *6205ZZ 24.8

D100LD 2 215 180 250 15 4 *6206ZZ *6305ZZ 34.6

D112MD 3 215 180 250 15 4 *6306ZZ *6306ZZ 48

Note:
1. Tolerance of Shaft End Diameter D: Under Ø28:j6, Ø38 to Ø48:k6.
2. Tolerance of N: h7.
3. Bearing with mark*: Grease Packed Shielded Rolling Bearings.
4. All data is subject to change without prior notification. Not to be used for
installation purposes without referring to TECO Electric Europe Limited.

standardefficiency 7
dimensions flange
frames 132S - 280M mounted

D132 - D280 D132 - D200 D225 - D280

dimensions in mm
Output (kW) Frame

B5
2P 4P 6P 8P No. AC D E F G KK L

5.5/7.5 5.5 3 2.2 D132S 275 38 80 10 33 1-M25x1.5 470

- 7.5 4/5.5 3 D132M 275 38 80 10 33 1-M25x1.5 510

11/15 11 7.5 4/5.5 D160M 330 42 110 12 37 2-M32x1.5 615

18.5 15 11 7.5 D160L 330 42 110 12 37 2-M32x1.5 670

22 18.5 - - D180M 380 48 110 14 42.5 2-M32x1.5 700

- 22 15 11 D180L 380 48 110 14 42.5 2-M32x1.5 740

30/37 30 18.5/22 15 D200L 420 55 110 16 49 2-M50x1.5 770

- 37 - 18.5 D225S 470 60 140 18 53 2-M50x1.5 815


Advantage

45 - - - 470 55 110 16 49 2-M50x1.5 820


D225M
- 45 30 22 470 60 140 18 53 2-M50x1.5 845

55 - - - 510 60 140 18 53 2-M63x1.5 910


D250M
- 55 37 30 510 65 140 18 58 2-M63x1.5 910

75 - - - 580 65 140 18 58 2-M63x1.5 985


D280S
- 75 45 37 580 75 140 20 67.5 2-M63x1.5 985

90 - - - 580 65 140 18 58 2-M63x1.5 1035


D280M
- 90 55 45 580 75 140 20 67.5 2-M63x1.5 1035

F ra m e B e a r in g s A p p r o x .W t .

No. M N P S T D r iv e e n d N o n - D r iv e e n d (k g )

D 132S 265 230 300 4 -Ø 1 5 4 6 3 0 8 Z Z -C 3 * 6 3 0 8 Z Z -C 3 * 60

D 132M 265 230 300 4 -Ø 1 5 4 6 3 0 8 Z Z -C 3 * 6 3 0 8 Z Z -C 3 * 67

D 160M 300 250 350 4 -Ø 1 9 5 6 3 0 9 Z Z -C 3 * 6 3 0 9 Z Z -C 3 * 107

D 160L 300 250 350 4 -Ø 1 9 5 6 3 0 9 Z Z -C 3 * 6 3 0 9 Z Z -C 3 * 131

D 180M 300 250 350 4 -Ø 1 9 5 6 3 1 1 -C 3 6311C 3 130

D 180L 300 250 350 4 -Ø 1 9 5 6 3 1 1 -C 3 6311C 3 174

D 200L 350 300 400 4 -Ø 1 9 5 6 3 1 2 -C 3 6 3 1 2 -C 3 225

D 225S 400 350 450 8 -Ø 1 9 5 6 3 1 3 -C 3 6 3 1 3 -C 3 278

D 225M 400 350 450 8 -Ø 1 9 5 6 3 1 3 -C 3 6 3 1 3 -C 3 300

D 250M 500 450 550 8 -Ø 1 9 5 6 3 1 4 -C 3 6 3 1 4 -C 3 379

D 280S 500 450 550 8 -Ø 1 9 5 6 3 1 4 -C 3 * / 6 3 1 7 -C 3 ** 6 3 1 4 -C 3 * / 6 3 1 7 -C 3 ** 490

D 280M 500 450 550 8 -Ø 1 9 5 6 3 1 4 -C 3 * / 6 3 1 7 -C 3 ** 6 3 1 4 -C 3 * / 6 3 1 7 -C 3 ** 558

N .B . * 2 p o l e / * * 4 ,6 ,8 p o l e

Note:
1. Tolerance of Shaft End Diameter D: Ø38 to Ø48:k6, Ø55 and above:m6.
2. Tolerance of N: h7.
3. Bearing with mark*: Grease Packed Shielded Rolling Bearings.
4. All data is subject to change without prior notification. Not to be used for
installation purposes without referring to TECO Electric Europe Limited.

standardefficiency 8
dimensions vertically
frames 180M - 355L mounted

D180 - D200 D225 - D355

V1
dimensions in mm
M o unting d im e ns io ns (m m ) O ve ra ll d im e ns io ns (m m )
F ra m e P o le s
D E F G M N P R* S T AC HF L KK

1 80 M 2.4 .6 .8 48 110 14 42 .5 300 2 50 35 0 0 4-Ø 1 9 5 380 5 00 760 2-M 32 X 1 .5

1 8 0L 2.4 .6 .8 48 110 14 42 .5 300 2 50 35 0 0 4-Ø 1 9 5 380 5 00 800 2-M 32 X 1 .5

2 0 0L 2.4 .6 .8 55 110 16 49 350 3 00 40 0 0 4-Ø 1 9 5 420 5 50 840 2-M 50 X 1 .5

Advantage
2 25 S 4 .8 60 140 18 53 400 3 50 45 0 0 8-Ø 1 9 5 470 6 10 905 2-M 50 X 1 .5

2 55 110 16 49 400 3 50 45 0 0 8-Ø 1 9 5 470 6 10 910


2 25 M 2-M 50 X 1 .5
4.6 .8 60 140 18 53 400 3 50 45 0 0 8-Ø 1 9 5 470 6 10 935

2 60 140 18 53 500 4 50 55 0 0 8-Ø 1 9 5 510 6 50 10 1 5


2 50 M 2-M 63 X 1 .5
4.6 .8 65 140 18 58 500 4 50 55 0 0 8-Ø 1 9 5 510 6 50 10 1 5

2 65 140 18 58 500 4 50 55 0 0 8-Ø 1 9 5 580 7 20 11 1 0


2 80 S 2-M 63 X 1 .5
4.6 .8 75 140 20 67 .5 500 4 50 55 0 0 8-Ø 1 9 5 580 7 20 11 1 0

2 65 140 18 58 500 4 50 55 0 0 8-Ø 1 9 5 580 7 20 11 5 0


2 80 M 2-M 63 X 1 .5
4.6 .8 75 140 20 67 .5 500 4 50 55 0 0 8-Ø 1 9 5 580 7 20 11 5 0

2 65 140 18 58 600 5 50 66 0 0 8-Ø 2 4 6 645 9 00 12 8 0


3 15 S 2-M 63 X 1 .5
4.6 .8 .10 80 170 22 71 600 5 50 66 0 0 8-Ø 2 4 6 645 9 00 15 1 0

2 65 140 18 58 600 5 50 66 0 0 8-Ø 2 4 6 645 9 00 13 1 0


3 15 M 2-M 63 X 1 .5
4.6 .8 .10 80 170 22 71 600 5 50 66 0 0 8-Ø 2 4 6 645 9 00 14 3 0

2 65 140 18 58 600 5 50 66 0 0 8-Ø 2 4 6 645 9 00 13 1 0


3 1 5L 2-M 63 X 1 .5
4.6 .8 .10 80 170 22 71 600 5 50 66 0 0 8-Ø 2 4 6 645 9 00 14 3 0

2 75 140 20 67 .5 740 6 80 80 0 0 8-Ø 2 4 6 710 1 0 10 16 4 0


3 55 M 2-M 75 X 1 .5
4.6 .8 .10 95 170 25 86 740 6 80 80 0 0 8-Ø 2 4 6 710 1 0 10 16 7 0

2 75 140 20 67 .5 740 6 80 80 0 0 8-Ø 2 4 6 710 1 0 10 16 4 0


3 5 5L 2-M 75 X 1 .5
4.6 .8 .10 95 170 25 86 740 6 80 80 0 0 8-Ø 2 4 6 710 1 0 10 16 7 0

Note:
1. Tolerance of Shaft End Diameter D: Under Ø28:j6, Ø38 to Ø48:k6.
2. Tolerance of Shaft Centre Height H: Under 250:+0, -0.5; Above 280: +0,-1.
3. Bearing with mark*: Grease Packed Shielded Rolling Bearings.
4. All data is subject to change without prior notification. Not to be used for
installation purposes without referring to TECO Electric Europe Limited.
5. *R = distance from flange to shaft shoulder.

standardefficiency 9
performance data EFF1*
0.75kW - 45kW TEFC, Class F, S1 (MCR) Duty

Max Sound
DOL DOL Rotor Load Pressure
Current (amp) Efficiency (%) Power starting starting Pull up Pull out inertia inertia (avg no
at volts at load factor current torque torque torque mr2 m r2 load
Rated @1m)
380 400 415 100 75 50 100 75 50 (%FLC) (%FLT) (%FLT) (%FLT) (kgm2) (kgm2)
kW Speed Frame db(A)
0.75 2860 D80 1.63 1.55 1.49 82.0 82.0 79.0 85.0 78.5 65.5 805 340 340 380 0.002 0.3 61
0.75 1400 D80 1.97 1.87 1.8 79.0 78.5 75.0 73.0 63.0 65.5 667 330 320 330 0.003 0.8 50
0.75 940 D90S 2.15 2.04 1.97 78.0 78.0 75.0 67.5 58.0 56.0 609 200 200 250 0.005 2.8 50
1.1 2840 D80 2.33 2.21 2.13 83.5 84 82 87.5 82 70.5 751 300 290 330 0.002 0.3 61
1.1 1415 D90S 2.59 2.46 2.37 83.8 83.0 81.0 80.0 72.5 60.0 675 250 215 270 0.004 1.3 52
1.1 940 D90L 3 2.85 2.75 82.0 80.0 77.0 69.0 60.0 48.0 582 240 230 290 0.006 4.2 52
1.5 2855 D90S 3.12 2.97 2.86 85 85.5 83 85.5 80.5 68 804 330 300 330 0.003 0.4 61
1.5 1430 D90L 3.59 3.41 3.29 85.0 84.0 81.5 75.0 66.5 53.0 699 300 240 310 0.006 1.4 52
1.5 930 D100L 3.5 3.33 3.21 83.0 83.0 81.5 78.0 71.5 60.0 623 240 200 250 0.014 4 51
2.2 2855 D90L 4.49 4.26 4.11 86 86.5 85.5 88 83 72 803 320 290 330 0.004 0.4 61
2.2 1440 D100L 4.76 4.52 4.36 86.5 86.5 85.0 82.5 76.0 63.5 757 290 250 300 0.01 1.9 53
2.2 955 D112M 5.4 5.14 4.95 84.5 85.0 83.0 74.5 67.0 54.5 606 210 190 260 0.019 4.3 56
3 2875 D100L 5.85 5.56 5.36 88.5 88.5 87 87.5 83 73 896 400 320 370 0.006 0.8 57
3 1420 D100L 6.28 5.97 5.75 87.4 87.0 86.0 83.5 78.0 66.0 748 290 270 310 0.013 2.8 46
3 965 D132S 6.33 6.02 5.8 88.5 87.6 81.0 81.0 75.0 63.0 741 200 170 300 0.039 13 44
4 2880 D112M 7.65 7.27 7.01 89.5 90 89 91 88 81 856 280 240 350 0.012 0.8 57
4 1445 D112M 8.34 7.93 7.64 89.0 89.0 88.0 84.0 80.0 68.0 785 240 180 300 0.017 3.6 48
4 970 D132M 8.81 8.37 8.07 89.5 89.0 87.0 79.0 72.5 60.0 743 210 180 310 0.045 13 47
5.5 2915 D132S 10.6 10 9.67 91.5 91.5 90.5 88.9 78.5 83.5 776 220 190 280 0.016 1.1 62
Advantage+

5.5 1460 D132S 11.4 10.8 10.4 90.5 90.5 89.0 82.5 76.0 63.5 817 270 220 320 0.027 4.8 53
5.5 960 D132M 11.7 11.1 10.7 89.0 88.5 88.8 82.0 77.0 66.0 654 190 170 270 0.058 21 45
7.5 2895 D132S 14.3 13.6 13.1 91 91 90 87 85 78.5 687 210 180 260 0.02 1.2 64
7.5 1455 D132M 14.6 13.9 13.4 91.0 91.0 90.0 85.0 80.0 68.5 821 270 220 320 0.037 5.8 55
7.5 970 D160M 15.4 14.6 14.1 91.0 91.0 90.0 81.0 75.0 64.0 674 240 200 260 0.1 21 64
11 2935 D160M 20.1 19.1 18.4 92.5 92.5 92 91 89 18.4 761 230 200 280 0.041 2.1 71
11 1460 D160M 21.1 20 19.3 92.5 92.5 92.0 87.0 83.5 19.3 725 230 180 270 0.08 7.8 59
11 975 D160L 23.7 22.5 21.7 91.0 90.5 89.0 79.0 72.5 21.7 737 280 230 280 0.15 27 58
15 2935 D160M 27 25.6 2.7 92.5 92 91.5 91 88 24.7 789 240 210 290 0.054 2.2 71
15 1460 D160L 27.7 26.4 25.4 93.0 93.0 92.5 88.0 84.5 25.4 728 230 180 270 0.1 9.4 60
15 970 D180LC 29.5 28 27 91.5 92.0 92.0 84.0 79.5 27.0 611 230 190 250 0.31 30 60
18.5 2925 D160L 33.3 31.6 30.5 93 93 93 91.5 89.5 30.5 803 260 210 300 0.067 2.7 72
18.5 1470 D180MC 35.5 33.7 32.5 94.0 94.0 93.5 85.0 81.0 32.5 754 240 180 270 0.16 15 63
18.5 975 D200LC 37.6 35.7 34.4 93.0 93.5 93.0 81.0 77.5 34.4 650 230 200 250 0.41 39 57
22 2935 D180MA 41.6 39.5 38.1 93.5 93.5 92.5 87.5 84.5 38.1 787 250 210 300 0.085 3.7 73
22 1465 D180LC 42 39.9 38.5 94.0 94.0 93.5 86.0 82.5 38.5 701 230 180 270 0.19 15 63
22 975 D200LC 44.1 41.9 40.4 93.5 93.5 93.5 82.5 79.5 40.4 619 220 190 250 0.49 43 60
30 2955 D200LA 54.1 51.5 49.6 94 94 93 89 87.5 49.6 685 175 150 260 0.14 5.1 76
30 1470 D200LC 55.1 52.4 50.5 94.5 94.5 94.5 87.0 85.5 50.5 772 175 190 270 0.32 17 64
30 980 D225MC 56.4 53.6 51.7 94.0 94.0 93.5 85.5 82.0 51.7 590 230 190 230 0.68 65 62
37 2950 D200LA 66.6 63.3 61 94.5 94.5 93.5 90 88 61 656 155 135 260 0.15 6.2 78
37 1475 D225SC 70.2 66.7 64.3 95.0 95.0 94.5 85.0 81.0 64.3 669 200 180 240 0.5 20 70
37 985 D250SC 69.3 65.9 63.5 94.0 94.5 94.0 87.0 83.5 63.5 638 210 200 250 1 61 68
45 2955 D225MA 78.6 74.7 72 94.5 94.5 93.5 92.0 91.0 88.0 665 140 119 230 0.3 8 76
45 1475 D225MC 84.7 80.4 77.5 95.0 95.0 94.5 85.0 81.0 72.5 640 200 170 250 0.5 24 70
45 985 D250MC 82.7 78.6 75.7 94.5 95.0 94.5 87.5 85.0 77.5 705 230 195 250 1.3 72 67

Note:
1. All figures are based on full load tests carried out on 400 Volt 3 Phase 50Hz motors.
2. Test method: EN60034 Part 2.
3. Tolerance: EN60034 Part 1.
4. All data is subject to change without prior notification. Not to be used for installation
purposes without referring to TECO Electric Europe Limited.
5. *EFF1 applies to the motor range 1.1kW - 90kW, 2 and 4 pole.
6. Outputs and performance comply with UK government ECA scheme.
7. ECA scheme compliant 8 pole motors are also available from 5.5kW - 90kW.

premiumefficiency 10
performance data EFF1*
55kW - 400kW TEFC, Class F, S1 (MCR) Duty

M ax S o und
DOL DOL R o to r L o ad P ressure
C urrent (am p ) E fficiency (% ) P ow er starting starting P ull up P ull out inertia inertia (avg no
at vo lts at lo ad factor current to rq ue to rq ue to rque m r2 m r2 lo a d
R ated @ 1m )
380 400 415 100 75 50 100 75 50 (% FLC ) (% F L T ) (% F L T ) (% FL T ) (kg m 2 ) (kg m 2)
kW S p eed Fram e d b (A)
55 2960 D 250S A 98.3 93.4 90 95.0 94.0 94.0 89.5 88.0 87.0 705 150 128 250 0.4 10 80
55 1480 D 250S C 101 95.5 92.1 95.5 95.0 94.5 87.0 84.0 77.0 700 180 153 260 1 39 74
55 984 D 280S C 103 98.3 94.8 95.0 94.5 94.0 85.0 82.5 75.0 678 140 119 230 2.1 102 75
75 2960 D 250M A 131 125 120 95.5 95.5 95.0 91.0 88.0 85.0 685 140 119 250 0.5 10 81
75 1480 D 250M C 137 130 126 95.5 95.5 95.0 87.0 84.0 77.0 650 220 187 240 1.1 44 73
75 984 D 280M C 139 132 127 95.3 94.8 94.3 86.0 83.3 76.0 688 140 119 230 2.8 127 75
90 2960 D 280S A 161 153 147 95.4 94.8 94.0 89.0 87.5 82.0 712 110 93 230 0.7 16 80
90 1480 D 280S B 164 156 151 95.6 95.0 94.2 87.0 84.2 78.0 694 140 119 230 2 56 78
90 985 D 315S B 167 159 153 95.3 94.9 94.8 86.0 83.3 76.0 689 155 131 230 4.3 150 79
110 2960 D 280M A 195 186 179 95.4 95.0 94.8 89.7 88.0 82.0 715 105 89 230 0.9 18 80
110 1482 D 280S C 198 188 182 95.8 95.2 94.4 88.0 84.5 78.5 703 140 119 230 2.4 68 78
110 985 D 315M C 202 192 185 95.8 95.3 94.9 86.2 84.0 76.5 689 140 119 220 5 175 75
110 737 D 315A B 217 206 198 94.8 94.5 93.0 81.4 76.2 65.6 643 120 108 220 7.5 320 75
132 2976 D 315S A 233 221 213 95.8 95.2 94.3 90.0 88.0 83.0 723 100 85 220 1.3 20 80
132 1482 D 315S C 236 224 215 96.2 95.6 94.8 88.5 85.0 79.5 741 140 119 220 3.1 75 78
132 986 D 315M B 243 231 222 95.8 95.4 95.3 86.2 84.5 77.5 694 150 127 220 5.7 228 79
132 737 D 315A B 259 246 237 95.0 94.5 93.1 81.5 76.5 65.6 638 110 100 220 8.3 365 75
150 2976 D 315M A 263 250 241 96.0 95.4 94.5 90.3 89.0 83.5 724 95 80 220 1.5 23 83
150 1485 D 315M C 268 254 245 96.2 95.6 94.8 88.5 85.0 80.0 709 140 119 220 3.6 91 78
150 985 D 315A B 276 262 252 95.3 94.8 93.5 87.0 85.0 78.0 697 110 100 220 7.3 260 79
150 737 D 315A B 292 277 267 95.2 94.8 93.2 82.0 78.0 69.0 655 100 90 220 9.1 400 75

Advantage+
185 2982 D 315M A 323 307 296 95.9 94.7 93.5 90.7 88.8 86.4 677 105 93 215 2 30 83
185 1486 D 315M B 324 308 294 96.0 95.4 94.5 90.3 89.2 83.5 715 140 119 220 3.7 78 78
185 985 D 315A B 338 321 310 95.5 95.0 93.5 87.0 85.0 79.0 673 120 110 220 8.9 270 79
185 737 D 315C B 359 341 329 95.5 94.8 93.5 82.0 79.0 69.0 634 110 100 220 11.7 450 77
200 2970 D 315A A 350 332 320 96.0 96.0 95.5 90.5 90.0 86.0 722 90 80 240 2.2 30 83
200 1475 D 315A B 358 340 328 95.8 95.2 94.0 88.6 87.0 83.0 726 100 90 240 5.9 130 81
200 987 D 315C B 360 342 329 95.5 95.4 94.6 88.5 86.5 80.0 699 100 85 230 11.5 350 81
200 738 D 315D B 388 369 355 95.5 95.0 93.5 82.0 78.0 69.0 653 100 90 220 13.6 520 78
250 2970 D 315C A 437 415 400 96.0 95.5 94.0 90.5 89.5 86.0 720 85 77 240 2.85 40 85
250 1480 D 315C B 447 424 409 96.0 95.5 94.0 88.6 87.0 83.0 700 100 90 240 6.9 150 82
250 985 D 315D B 452 430 414 96.0 95.6 94.5 87.5 85.9 79.0 695 90 80 220 12.9 400 82
250 738 D 315A B 483 459 442 95.9 95.3 94.0 82 78.0 69.0 650 110 100 210 20.3 750 79
280 2975 D 315D A 484 460 444 96.3 95.8 94.5 91.2 90.0 87.0 735 85 77 240 3.35 45 85
280 1480 D 315C B 499 474 457 96.3 95.8 94.5 88.5 87.0 83.3 720 110 100 240 7.6 150 83
280 985 D 355A B 506 481 464 96.0 95.6 94.5 87.5 86.0 80.0 710 90 80 220 19.2 550 82
280 740 D 355C B 540 514 495 96.0 95.5 94.5 82 78.0 69.0 665 100 90 210 22.4 800 80
315 2975 D 315D A 544 517 498 96.4 96.0 94.5 91.2 90.0 87.0 745 85 77 240 3.9 52 85
315 1480 D 315D B 561 533 514 96.3 95.8 94.5 88.5 87.0 83.8 710 100 90 240 8.6 165 85
315 987 D 355C B 566 538 519 96.0 95.6 94.5 88 86.0 80.0 705 90 80 210 21.0 550 83
315 740 D 400A B 616 585 564 96.0 95.5 94.5 81 76.0 66.0 650 100 90 210 29.3 950 80
355 2975 D 355A A 612 581 560 96.4 96.0 94.8 91.5 90.0 89.0 730 85 77 240 4.725 60 85
355 1480 D 355A B 632 600 578 96.5 96.0 94.8 88.5 87.0 83.5 710 100 90 230 12.1 195 85
355 987 D 400A B 640 608 586 96.3 95.8 94.8 87.5 86.0 80.0 700 85 77 200 22.7 550 83
355 740 D 400C B 693 658 635 96.1 95.6 94.5 81 77.0 68.0 645 95 85 210 30.5 960 80
400 2978 D 400C A 688 654 630 96.5 96.1 94.8 91.5 90.0 88.0 735 80 72 240 7.7 85 85
400 1485 D 355C B 711 675 651 96.6 96.0 94.8 88.5 87.0 83.5 715 95 85 230 13.5 210 85
400 987 D 400A B 721 685 660 96.3 95.8 94.8 87.5 88.0 80.0 705 80 72 210 25.0 580 83
400 740 D 450A B 771 733 706 96.1 95.6 94.6 82 79.5 69.5 660 95 85 210 50.0 1300 83

Note:
1. All figures are based on full load tests carried out on 400 Volt 3 Phase 50Hz motors.
2. Test method: EN60034 Part 2.
3. Tolerance: EN60034 Part 1.
4. All data is subject to change without prior notification. Not to be used for installation
purposes without referring to TECO Electric Europe Limited.
5. *EFF1 applies to the motor range 1.1kW - 90kW, 2 and 4 pole.
6. Outputs and performance comply with UK government ECA scheme.
7. ECA scheme compliant 8 pole motors are also available from 5.5kW - 90kW.

premiumefficiency
8. Frames for 200kW to 400kW may be capable of increased outputs: please refer
to TECO Electric Europe Limited.

11
dimensions foot
frames 80 - 200LC mounted

Fig 1 Fig 2 dimensions in mm

B3
Output (kW) Fig
Frame No.
2P 4P 6P No. A AB AC AD B C D E F G H

1.1 - - D80 1 125 155 177 179 100 50 19 40 6 15.5 80

1.5 1.1 - D90S 1 140 170 200 192 100 56 24 50 8 20 90

2.2 1.5 1.1 D90L 1 140 170 200 192 125 56 24 50 8 20 90

3 2.2/3 1.5 D100L 2 160 195 219 202 140 63 28 60 8 24 100

4 4 2.2 D112M 2 190 224 238 211 140 70 28 60 8 24 112

5.5/7.5 5.5 3 D132S 2 216 250 273 249 140 89 38 80 10 33 132


Advantage+

- 7.5 4/5.5 D132M 2 216 250 273 249 178 89 38 80 10 33 132

11/15 11 7.5 D160M 1 254 300 334 287 210 108 42 110 12 37 160

18.5 15 11 D160L 1 254 300 334 287 254 108 42 110 12 37 160

22 - - D180MA 2 279 355 382 312 241 121 48 110 14 42.5 180

- 18.5 - D180MC 1 279 355 382 312 250 121 48 110 14 42.5 180

- 22 15 D180LC 1 279 355 382 312 279 121 48 110 14 42.5 180

30/37 - - D200LA 2 318 400 420 374 305 133 55 110 16 49 200

- 30 18.5/22 D200LC 2 318 400 420 374 305 133 55 110 16 49 200

Frame Bearings Approx.Wt.

No. HD K KK L Drive end Non-Drive end (kg)

D80 1 - M25XP1.5 272 *6204ZZ *6204ZZ 17

D90S 1 - M25XP1.5 297 *6205ZZ *6205ZZ 21

D90L 1 - M25XP1.5 322 *6205ZZ *6205ZZ 25

D100L 2 243 M25XP1.5 363 *6206ZZ *6305ZZ 35

D112M 2 265 M25XP1.5 382 *6306ZZ *6306ZZ 46

D132S 310 12 M25XP1.5 446 *6308ZZ *6306ZZ 75

D132M 310 12 M25XP1.5 484 *6308ZZ *6306ZZ 82

D160M 377 14.5 M32XP1.5 604 *6309ZZ *6307ZZ 130

D160L 377 14.5 M32XP1.5 648 *6309ZZ *6307ZZ 158

D180MA 421 14.5 M32XP1.5 667 (6211C3) (6211C3) 180

D180MC 421 14.5 M32XP1.5 667 *6311ZZ *6310ZZ 165

D180LC 421 14.5 M32XP1.5 705 *6311ZZ *6310ZZ 205

D200LA 469 18.5 M40XP1.5 768 (6312C3) (6212C3) 280

D200LC 469 18.5 M40XP1.5 768 6312 6212 280

Dimensions for larger frames available on request

Note:
1. Tolerance of Shaft End Diameter D: Under Ø28:j6, Ø38 to Ø48:k6, Ø55 to Ø70:m6.
2. Tolerance of Shaft Centre Height H: +0, -0.5 (frame 280SA and above: +0, -1).
3. Parentheses Bearing Numbers Apply for 2 pole motors.
4. Bearing with mark*: Grease Packed Shielded Rolling Bearings.

premiumefficiency
5. All data is subject to change without prior notification. Not to be used for
installation purposes without referring to TECO Electric Europe Limited.

12
dimensions foot
frames 225SC - 315MB mounted

Fig 1 Fig 2 dimensions in mm

B3
Output (kW ) Fig
Frame No.
2P 4P 6P No. A AB AC AD B C D E F G H

- 37 - D 225SC 2 356 450 458 427 286 149 60 140 18 53 225

45 - - D225M A 2 356 450 458 427 311 149 55 110 16 49 225

- 45 30 D 225MC 2 356 450 458 427 311 149 60 140 18 53 225

55 - - D250SA 2 406 500 510 493 311 168 60 140 18 53 250

- 55 37 D 250SC 2 406 500 510 493 311 168 70 140 20 62.5 250

Advantage+
75 - - D250M A 2 406 500 510 493 349 168 60 140 18 53 250

- 75 45 D 250MC 2 406 500 510 493 349 168 70 140 20 62.5 250

90 - - D280SA 2 457 560 577 540 368 190 65 140 18 58 280

- 90 55 D 280SB 2 457 560 577 540 368 190 80 170 22 71 280

110 - - D280M A 2 457 560 577 540 419 190 65 140 18 58 280

- 110 75 D280M B 2 457 560 577 540 419 190 80 170 22 71 280

132 - - D315SA 2 508 615 637 565 406 216 65 140 18 58 315

- 132 90 D 315SB 2 508 615 637 565 406 216 85 170 22 76 315

150/185 - - D315M A 2 508 615 637 565 457 216 65 140 18 58 315

- 150, 185 110, 132 D315M B 2 508 615 637 565 457 216 85 170 22 76 315

F ra m e B e a rin g s A p p ro x .W t.

N o. HD K KK L D riv e e n d N o n -D riv e e n d (k g )

D225SC 524 1 8 .5 M 5 0 X P 1 .5 811 6313 6213 320

D 225M A 524 1 8 .5 M 5 0 X P 1 .5 806 (6 3 1 2 C 3 ) (6 2 1 2 C 3 ) 355

D 225M C 524 1 8 .5 M 5 0 X P 1 .5 836 6313 6213 358

D 250SA 575 24 M 6 3 X P 1 .5 8 7 2 .5 (6 3 1 3 C 3 ) (6 2 1 3 C 3 ) 470

D250SC 575 24 M 6 3 X P 1 .5 8 7 2 .5 N U216 6213 510

D 250M A 575 24 M 6 3 X P 1 .5 9 1 0 .5 (6 3 1 3 C 3 ) (6 2 1 3 C 3 ) 540

D 250M C 575 24 M 6 3 X P 1 .5 9 1 0 .5 N U216 6213 565

D 280SA 660 24 M 6 3 X P 1 .5 992 6314C 3 6314C 3 680

D 280SB 660 24 M 6 3 X P 1 .5 1022 6318 6316 700

D 280M A 660 24 M 6 3 X P 1 .5 1042 6314C 3 6314C 3 780

D 280M B 660 24 M 6 3 X P 1 .5 1072 6318 6316 800

D 315SA 743 28 M 6 3 X P 1 .5 1086 6314C 3 6314C 3 990

D 315SB 743 28 M 6 3 X P 1 .5 1116 6320 6316 1030

D 315M A 743 28 M 6 3 X P 1 .5 1137 6314C 3 6314C 3 1200

D 315M B 743 28 M 6 3 X P 1 .5 1167 6320 6316 1220

Dimensions for larger frames available on request


Note:
1. Tolerance of Shaft End Diameter D: Under Ø28:j6, Ø38 to Ø48:k6, Ø55 to Ø70:m6.
2. Tolerance of Shaft Centre Height H: +0, -0.5 (frame 280SA and above: +0, -1).
3. Parentheses Bearing Numbers Apply for 2 pole motors.
4. All data is subject to change without prior notification. Not to be used for

premiumefficiency
installation purposes without referring to TECO Electric Europe Limited.

13
dimensions flange
frames 63D - 200LD mounted

dimensions in mm

V1/B5
O u tp u t (k W ) Fra m e F ig
Advantage+

2P 4P 6P 8P N o. No. AC D E F G KK L

0 .1 8 5 0 .1 8 5 - - D 63D 1 144 11 23 4 8 .5 M 2 0 x 1 .5 238

0 .3 7 /0 .5 5 0 .3 7 0 .1 8 5 - D 71D 1 162 14 30 5 11 M 2 0 x 1 .5 266

0 .7 5 /1 .1 0 .5 5 0 .3 7 /0 .5 0 .1 8 5 D 80D 2 177 19 40 6 1 5 .5 M 2 5 x 1 .5 272

1 .5 1 .1 0 .7 5 0 .3 7 D90SD 3 200 24 50 8 20 M 2 5 x 1 .5 336

2 .2 1 .5 1 .1 0 .5 5 D 90LD 3 200 24 50 8 20 M 2 5 x 1 .5 361

3 2 .2 /3 1 .5 0 .7 5 /1 .1 D 100LD 2 219 28 60 8 24 M 2 5 x 1 .5 363

4 4 2 .2 1 .5 D 112M D 3 238 28 60 8 24 M 2 5 x 1 .5 422

5 .5 /7 .5 5 .5 3 2 .2 D132SD 2 273 38 80 10 33 M 4 0 x 1 .5 446

- 7 .5 4 /5 .5 3 D 132M D 2 273 38 80 10 33 M 4 0 x 1 .5 484

1 1 /1 5 11 7 .5 4 /5 .5 D 160M D 3 334 42 110 12 37 M 4 0 x 1 .5 604

1 8 .5 15 11 7 .5 D 160LD 4 334 42 110 12 37 M 4 0 x 1 .5 648

22 1 8 .5 - - D 180M D 4 382 48 110 14 4 2 .5 M 4 0 x 1 .5 667

- 22 15 11 D 180LD 4 382 48 110 14 4 2 .5 M 4 0 x 1 .5 705

3 0 /3 7 30 1 8 .5 /2 2 15 D 200LD 4 420 55 110 16 49 M 5 0 x 1 .5 768

F ra m e F ig . B e a r in g s A p p r o x .W t.

N o. N o. M N P S T D r iv e e n d N o n -D r iv e e n d (k g )

D 63D 1 115 95 140 10 3 *6 2 0 1 Z Z *6 2 0 1 Z Z 9 .2

D 71D 1 130 110 160 10 3 .5 *6 2 0 2 Z Z *6 2 0 2 Z Z 12

D 80D 2 165 130 200 12 3 .5 *6 2 0 4 Z Z *6 2 0 4 Z Z 17

D90SD 3 165 130 200 12 3 .5 *6 2 0 5 Z Z *6 2 0 5 Z Z 2 2 .8

D 90LD 3 165 130 200 12 3 .5 *6 2 0 5 Z Z *6 2 0 5 Z Z 2 4 .8

D 100LD 2 215 180 250 15 4 *6 2 0 6 Z Z *6 3 0 5 Z Z 3 4 .6

D 112M D 3 215 180 250 15 4 *6 3 0 6 Z Z *6 3 0 6 Z Z 48

D132SD 2 265 230 300 15 4 *6 3 0 8 Z Z *6 3 0 6 Z Z 70

D 132M D 2 265 230 300 15 4 *6 3 0 8 Z Z *6 3 0 6 Z Z 80

D 160M D 4 300 250 350 19 5 *6 3 0 9 Z Z *6 3 0 7 Z Z 120

D 160LD 4 300 250 350 19 5 *6 3 0 9 Z Z *6 3 0 7 Z Z 141

D 180M D 4 300 250 350 19 5 * (6 2 1 1 C 3 )* 6 3 1 1 Z Z (6 2 1 1 C 3 )* 6 3 1 0 Z Z 196

D 180LD 4 300 250 350 19 5 *6 3 1 1 Z Z *6 3 1 0 Z Z 210

D 200LD 4 350 300 400 19 5 (6 3 1 2 C 3 ) 6 3 1 2 (6 2 1 2 C 3 ) 6 2 1 2 280

Note:
1. Tolerance of Shaft End Diameter D: Under Ø28:j6, Ø38 to Ø48:k6.
2. Tolerance of Shaft Centre Height H: Under 250:+0, -0.5; Above 280: +0,-1.
3. Parentheses Bearing Numbers Apply for 2 pole motors.
4. Bearing with mark*: Grease Packed Shielded Rolling Bearings.

premiumefficiency
5. All data is subject to change without prior notification. Not to be used for
installation purposes without referring to TECO Electric Europe Limited.

14
dimensions flange
frames 225SCD - D315MBD mounted

B5
dimensions in mm

O utp ut (k W ) F ra m e F ig
2P 4P 6P 8P No. No. AC D E F G KK L
- 37 - 1 8 .5 D 225SC D 5 458 60 140 18 53 M 5 0 X 1 .5 811

Advantage+
45 - - - D 225M AD 5 458 55 110 16 49 M 5 0 X 1 .5 806
- 45 30 22 D 225M C D 5 458 60 140 18 53 M 5 0 X 1 .5 836
*55 - - - D 250SAD 5 510 60 140 18 53 M 6 3 X 1 .5 8 7 2 .5
- 55 37 30 D 250SC D 5 510 70 140 20 6 2 .5 M 6 3 X 1 .5 8 7 2 .5
*75 - - - D 250M AD 5 510 60 140 18 53 M 6 3 X 1 .5 9 1 0 .5
75 45 37 D 250M C D 5 510 70 140 20 6 2 .5 M 6 3 X 1 .5 9 1 0 .5
*90 - - - D 280SAD 6 576 65 140 18 58 M 6 3 X 1 .5 977
- 90 55 45 D 280SC D 6 576 80 170 22 71 M 6 3 X 1 .5 1007
*1 10 - - - D 280M AD 6 576 65 140 18 58 M 6 3 X 1 .5 1027
- 110 75 55 D 280M C D 6 576 80 170 22 71 M 6 3 X 1 .5 1057
*1 32 - - - D 315SAD 6 576 65 140 18 58 M 6 3 X 1 .5 1076
- 132 90 75 D 315SC D 6 576 85 170 22 76 M 6 3 X 1 .5 1108
*1 5 0 /1 8 5 - - - D 315M AD 6 576 65 140 18 58 M 6 3 X 1 .5 1127
- 150 1 1 0 /1 3 2 90 D 315M C D 6 576 85 170 22 76 M 6 3 X 1 .5 1157
- *185 - - D 315M BD 6 576 85 170 22 76 M 6 3 X 1 .5 1157

F ra m e F ig . B e a r in g s A p p r o x .W t .
No. No. M N P S T D r iv e e n d N o n - D r iv e e n d (k g )
D 225S C D 5 400 350 450 19 5 6313 6213 3 3 8 .5
D 225M A D 5 400 350 450 19 5 (6 3 1 2 C 3 ) (6 2 1 2 C 3 ) 3 6 6 .5
D 225M C D 5 400 350 450 19 5 6313 6213 3 7 3 .5
D 250SA D 5 500 450 550 19 5 6313C 3 6213C 3 520
D 250S C D 5 500 450 550 19 5 N U316 6313 540
D 250M A D 5 500 450 550 19 5 6313C 3 6213C 3 570
D 250M C D 5 500 450 550 19 5 N U316 6313 600
D 280SA D 6 500 450 550 19 5 6314C 3 6314C 3 700
D 280S C D 6 500 450 550 19 5 N U318 6318 720
D 280M A D 6 500 450 550 19 5 6314C 3 6314C 3 800
D 280M C D 6 500 450 550 19 5 N U318 6318 820
D 315SA D 6 600 550 660 24 6 6314C 3 6314C 3 1010
D 315S C D 6 600 550 660 24 6 N U320 6318 1050
D 315M A D 6 600 550 660 24 6 6314C 3 6314C 3 1220
D 315M C D 6 600 550 660 24 6 N U320 6318 1250
D 315M B D 6 600 550 660 24 6 N U320 6318 1250

Dimensions for larger frames available on request

Note:
1. Tolerance of Shaft End Diameter D: Under Ø28:j6, Ø38 to Ø48:k6.
2. Tolerance of Shaft Centre Height H: Under 250:+0, -0.5; Above 280: +0,-1.
3. Parentheses Bearing Numbers Apply for 2 pole motors.
4. All data is subject to change without prior notification. Not to be used for

premiumefficiency
installation purposes without referring to TECO Electric Europe Limited.

15
climate change levy
energy efficiency
A new tax on energy use in industry, commerce, and small company advice, renewables, low carbon
agriculture and the public sector, the Climate Change technologies.
Levy was introduced in April 2001.
£100 million to be utilised as enhanced capital allow-
The tax will vary in its effect as some organisations will ances for investments in energy efficient technologies
be eligible for discount and some energy sources, or (emissions savings of 2.5 MtC/y from the levy
uses of energy, will be exempt. package).

Carbon dioxide emissions from energy use can affect


the climate, and the UK Government signed up to Climate Change Levy Costs
international commitments at Kyoto to address the Electricity Gas
issue of climate change. To this end, TECO Electric
Price/kWh % increase Price /kWh % increase
Europe Ltd can show you how to make better use of
3p 14.30% 0.6p 25%
energy and, subsequently, help you cut your costs year
4p 10.80% 0.7p 21%
after year, save on the Levy and protect the environment
- the Climate Change Levy became law on 28 July 5p 8.60% 0.8p 19%

2000. 6p 7.20% 0.9p 17%

Why a Levy? Exemptions and Discounts

The recent Marshall report investigated business use of


√ Electricity from ‘new’ renewable energy sources
energy and came to the conclusion that business in
and ‘good quality’ CHP (combined heat & power)
general wastes some 15-20% of energy. An Economic
will be exempt.
incentive was clerly necessary to improve energy
efficiency and, therefore, the CCL was announced in
the 1999 Budget. √ Northern Ireland - exemption on natural gas for 5
years.
The Climate Change Levy will be introduced on 1 April
2001 and, subject to obtaining EU state aids clearance √ Horticulture sector - 50% reduction in levy for 5
and the passing of the 2001 finance bill, will apply to all years.
industry and commerce
√ Energy intensive sectors can secure a rebate of
It will be intended to reduce energy consumption by 80% on levy by agreeing to energy efficiency
encouraging industry to adopt energy efficient targets.
measures and the levy will be calculated using the
following rates:
What can you do about it?
Electricity 0.43p/kWh
Gas/Coal 0.15p/kWh † Use energy more efficiently.
LPG 0.07p/kWh
† Invest in energy efficient equipment.
Each company will be able to claim a rebate on
National Insurance Contributions of 0.3% † Purchase ‘new’ renewables.

The Levy will raise £1 billion: - 0.15p/kWh gas - 0.15p/ † Seek advice from the Environment & Energy

ccl
kWh coal - 0.43p/kWh electricity - oil exempt
Helpline.
(attracts hydrocarbon oil duty) - 0.07p/kWh LPG.

This capital raised will be recycled to business via a


† Use TECO high efficiency motors and drives.
0.3% NICs cut (Revenue neutral to business - no gain
to the public sector - broadly neutral between industry
and services). £50 million will be used to expand
energy Efficiency Best Practice Programme (EEBPP)

16
enhanced capital allowance
reducing costs
Electric Motors/Variable Speed Drives And The Range of motors covered
Environment - the Kyoto protocol
1.1 to 400kW, 2, 4, 6 and 8 pole, totally enclosed.
Main points:
All multi speed motors for use on liquid or gaseous
„ Global commitment to 8% reduction in green movement applications.
house gas emissions.
Controllers or drives eligible under the ECA scheme are
„ Commitments vary by nation - e.g. UK 21.5%, only those installed for liquid or gas movement applica-
Germany 21%. tions such as pumps, fans and compressors. The
scheme is limited to those controllers designed specifi-
cally to electronically vary the speed of a motor.
„ UK Government target - 20% CO2 reduction by
2010. Variable Speed Drive Definition

„ Power station emissions must be reduced for the • Liquid or gas movement application
UK to meet target. • Electric means to vary speed of motor
• Act directly on electrical input to motor
„ Introduction of Climate Change Levy. • Must not detract from the performance of the
motor
Electric Motors & The Environment
Variable Speed Drives not eligible
In 1995, generating the electricity used by electric
motors in the UK alone caused emissions of 24 Mtc. Not able to sustain motor speed for at least one hour at
This was 17% of the UK’s total carbon emissions from 70% rated speed without causing overheating.
all sources. 130 TWh per annum £6, 600 million per
annum. Controllers which do not directly control motor shaft
speed.
Motor Energy Usage by UK Industrial Sector
How can we increase your business?
Motor Energy Usage % of total electricity
Industry
TWh/year usage per industry
• On-site energy audits.
Chemicals/Petrochemicals 15.3 60.5
Paper/Printing/Publishing 7.7 81.5 • Energy calculations and payback with TECO
Mining/Building Materials 7.7 83 energy saving programme.
Food/Beverage/Tobacco 6.5 61
Water 5.3 93.5 • Joint seminars and presentations promoting
Iron & Steel 5.3 52.5 vsds and Climate Change Programme.
Mechanical Engineering 4.8 58
Vehicle Manufacture 3.4 54.3 • Training on vsds, energy saving applications
Electrical Engineering 3.1 58 and software tools.
Other 11.8 65.3
• by achieving lower running costs through high
Summary efficiency labels therefore qualifying for enhanced
capital allowances.

eca
• The CCL energy tax will apply to every business
Further cost savings can be made by
within the non-domestic sector. fitting TECO variable speed drives.

• This will remain an additional 0.43p/kWh on


electricity charges.

• By agreeing to energy efficiency targets a rebate


of 80% can be achieved.

• Installing energy efficient motors will save users


money by contributing towards the energy
efficiency targets and help achieve the 80%
rebate. 17
TECO Products
Industrial cage motors - low voltage - IEC + NEMA
Industrial cage motors - high voltage
Drip proof motors
Hazardous area motors
Premium efficiency motors
Variable speed drives / Inverters (VSD’s)
Slip Ring motors
Synchronous motors
Stepper motors
Brake motors

TECO Publications available...


* Product overview * Minicon palm drive
* Advantage/Advantage Plus high and * Minicon Plus IP65 drive
premium efficiency cast iron motors * Speecon 7200JA variable speed
* Advantage Lite aluminium motors drives
* Open Advantage drip proof motors * Speecon 7200MA variable speed
* Low voltage motors (AEJC) drives
* High voltage motors (AEJK) * Speecon 7200GA variable speed
* HV motors drives
* Slip ring motors (AEEQ-AEJS) * Optim 2000 variable speed drives
* Guardian range - high temperature
resistant motors For more details please ring
+44 (0)161 877 8025,
fax us on +44 (0)161 877 8030,
contact us at enquiries@teco.co.uk,
or visit our web site at www.teco.co.uk.

18
TECO worldwide operations
EUROPE AMERICA CANADA
Teco Electric Europe Limited Teco-Westinghouse Motor Co. Teco-Westinghouse Motors (Canada) Inc
Teco Building PO Box 227 (78680-0277) 18060-109 Avenue
Marshall Stevens Way N-1H35 at Westinghouse Rd Edmonton
Trafford Park, Manchester Round Rock Alberta T5S 2K2
M17 1PP, England Texas 78681, USA Canada
Tel: +44 (0)161 877 8025 Tel: +1 512 255 4141 Tel: +1 780 444 8933
Fax: +44 (0)161 877 8030 Fax: +1 512 244 5500 Fax: +1 780 486 4575
www.teco.co.uk www.tecowestinghouse.com www.twmi.com

AUSTRALASIA
Teco Australia Pty Ltd
335-337 Woodpark Road
Smithfield, NSW 2164
Australia
Tel: +61 2 29765 8118
Fax: +61 2 29604 9330
www.teco.com.au

PACIFIC RIM
Taiwan Singapore Malaysia
Teco Electric & Machinery Co Ltd Teco Electric & Machinery (PTE) Ltd Teco Industry (Malaysia) SDN BHD
5F, No. 19-9 San Chong Road 18 Chin Bee Drive 2600 Jalan Perusahaan Baru
Nan Kang Singapore Kawasan Perusahaan Prai
Taipei 115 6119865 13600 Prai, Penang
Taiwan ROC Tel: +65 265 4622 Malaysia
Tel: +88 6 2 2655 3333 Fax: +65 265 7354 Tel: +60 (0)4 3909908
Fax: +88 6 2 2655 2231 www.teco.com.sg Fax: +60 (0)4 3909901-2
www.teco.com.tw

Hong Kong Japan Thailand


Tecoson Industrial Sankyo Co. Ltd Teco Electric & Machinery (Thai) Co., Ltd
Development (HK) Co Ltd Rm 301,9th R 128/1 Soi Watsrivareenoi
Rm 3504-07 Hong Kong Plaza Shinhamamatsucho Bldg Moo 7, Bangna - Trad Road Km.18
186-191 Connaught Rd West 1-27-9 Hamamatsucho Bangchalong, Bangplee
Hong Kong Shiba-daimon Samuthprakarn 10540
Tel: +852 2858 3220 Minato Ku, Tokyo, Japan Thailand
Fax: +852 2540 4592 Tel: +81 3 3435 7818 Tel: +662 3371311 - 20
Fax: +81 3 3578 8381 Fax: +662 3371630

Indonesia
P.T. Teco Multiguna Elektro
JL Bandengan Utara No. 83/1-2-3
Jakarta Utara - 14400
Indonesia
Tel: +62 21 6626065
Fax: +62 21 6626066

Advantage 19
TECOBuilding,MarshallStevensWay,TraffordPark,ManchesterM171PP.ENGLAND
Tel: +44 (0) 161 877 8025 Fax: +44 (0) 161 877 8030
e-mail:enquiries@teco.co.uk web:http://www.teco.co.uk

Your local TECO distributor

You might also like