Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Alpha Conne ct 4 8 Te chnica l m a nua l

A LPHATRON M ARI NE B V

S CHAARDI JK 2 3 P .O . B OX 2 1 0 0 3 T DI RECT + 3 1 (0 )1 0 -4534068 R ABOBANK 3 8 .1 8 .2 9 .0 6 5

3 0 6 3 N H R OTTERDAM – H AVEN 1 1 5 3 0 0 1 A A R OTTERDAM F DI RECT + 3 1 ( 0 ) 1 0 - 4 5 2 92 1 4 K VK 2 4 1 8 2 6 3 5

T HE N ETHERLANDS T HE N ETHERLANDS E COMMUNI CATI E@ ALPHATRONMARI NE. NL

Alphat ron Marine B. V. Rev . 1 2006- 05- 16


1.1.1 Power supply and alarm relay connection
The AlphaConnec t 48 is meant f or dual supply , a main supply of t en t aken f rom t he
generat or of t he ship, and a bat t ery bac k up supply of t en t aken f rom t he radio
bat t ery of t he ship.
The t w o supplies are t aken t hrough t he c able glands in t he bot t om of t he c abinet , and
c onnec t ed t o t he Pow er I nput Module ( PI M) . The PI M is loc at ed low right at t he
int erior bac kside of t he sy st em.
The f igure below show s t he PI M module:

Lay out of t he PI M pow er input module.

1.1.1.1 Power supply


The J1 c onnec t or is t he one t o c onnec t pow er, and t he pin lay out is desc ribed in
t he t able below :

Pin name Use


M+ 24V DC main supply posit iv e t erminal
M- 24V DC main supply negat iv e t erminal
B+ 24V DC bat t ery supply posit iv e t erminal
B- 24V DC bat t ery supply negat iv e t erminal
NC Alarm relay out put . Normal c losed t erminal
C Alarm relay out put . Cent er t erminal
NO Alarm relay out put . Normal open t erminal
F+ 24V DC out put f or auxiliary f an
F- 24V DC out put f or auxiliary f an

Not e t hat t he AlphaConnec t 48 c reat es galv anic c onnec t ion bet w een main and
bat t ery .

1.1.1.2 Alarm relay


Alphat ron Marine B. V. Rev . 1 2006- 05- 16
3 t erminals of t he PI M module J1 are dev ot ed t he alarm relay . The alarm relay is
ac t iv at ed w henev er only one of t he pow er supplies are present , or w henev er t he
pow er supply of t he AlphaConnec t 48 board magazine dec ides t o send an alarm
indic at ion. This c ould be c aused by high t emperat ure, f ault y pow er supply operat ion
or sof t w are break dow n.
I f t he AlphaConnec t 48 is operat ed on a single supply , loops bet w een t he M+ and B+
and M- and B- must be set , ot herw ise t he alarm relay w ill st ay in alarm st at e.

Alphat ron Marine B. V. Rev . 1 2006- 05- 16


5 . Se r vice
This c hapt er c ont ains inf ormat ion usef ul w hen perf orming serv ic e on t he
AlphaConnec t 48 sy st em.

5.1 Pre v e nt iv e m a int e na nce


I t is adv ised t o c arry out regular serv ic e as indic at ed in paragraphs 6. 1. 1 - 6. 1. 4

5 .1 .1 The phy sica l inst a lla t ion


Keep t he inside of t he AlphaConnec t 48 c lean and f ree f rom dust . Clean t he f an at
least onc e a y ear. Replac e t he f ans ev ery 3 y ears w hen operat ed at max 30 degrees
Celsius. The higher av erage t emperat ure of operat ion, t he more of t en t he f ans must
be replac ed.

5 .1 .2 File sy st e m of t he CP boa rd disk


Rest art t he sy st em at least onc e a y ear in order t o make t he sc andisk f eat ure of t he
st art - up proc edure c hec k t he f ile sy st em of t he disk.

5 .1 .3 Disk spa ce che ckout s


Chec k t he disk spac e onc e a y ear in order t o prev ent disk ov erf low .

5 .1 .4 Ca ll da t a m a int e na nce
I n order t o prev ent t he AlphaConnec t 48 c all dat a base ov erf low ing, make sure t hat
old c all dat a are alw ay s dest roy ed w henev er t hey are no longer needed. Keeping
unw ant ed c all dat a f or long periods w ill make t he AlphaConnec t 48 Call Dat a Manager
operat e slow ly .
This proc edure must be c arried out at least onc e a y ear, more f requent ly if t he
sy st em is handling a high t raf f ic densit y .

6 .2 List of re com m e nde d spa re pa rt s

Equipm e nt Orde r num be r


Pow er supply 1000- 110- 0020
CP1 or CP2 1000- 110- 1010
1000- 110- 1011
FI O board 1000- 110- 1030
Ext ension board 1000- 110- 1040

6 .3 Equipm e nt re quire d t o pe rform se rv ice


When t rav elling f or serv ic e be sure t o c arry t he f ollow ing:
• A set of rec ommended spare part s
• A port able PC w it h a net w ork c onnec t ion f or c onnec t ing t o t he AlphaConnec t
48
• The sy st em c onf igurat ion bac kup f ile
• 2 t elephones w it h a c able t o c onnec t t o t he f ront of t he ext ension boards
• A c able t hat c onnec t s t runk lines t o ext ension lines
• Opt ionally a VDU, key board and mouse f or c onnec t ing t o t he CP board

Alphat ron Marine B. V. Rev . 1 2006- 05- 16

You might also like