BUILDING CODE
CLASSIFICATION AND GENERAL
REQUIREMENTS OF ALL BUILDINGS
BY USE OR OCCUPANCY
USE OR OCCUPANCY UNIT AREA PER OCCUPANT Minimum of Two Exits other
(Sq. m.) than elevators are required
where number of occupant is
over
A. Dwellings 28 10
B. Hotels 18.6 10
Apartments 18.6 10
Dormitories 18.6 10
• Section 702
• Section 703
http://continuingeducation.construction.com/article.php
LOCATION ON PROPERTY
No buildings shall be constructed unless it adjoins a street
1.20 M
3.70 M
National Building Code of the Philippines
ELEVATOR
Min. 2.10 m
Min. 2.40 m
Min. 2.40 m
Min. 2.70m
MEZZANINE FLOORS
Min. 1.80 m.
Stairways 1
30 M
10 % FLOOR AREA
ARCADE
MIN. 3.00 M
1:12 RATIO
National Building Code of the Philippines
STAIRWAYS
A B
max.
3.60 m
Min. 2.00
m
Max. 1.20 m
3m
3m
1000 or more 4
EXIT 1 EXIT 2
EXIT DISTANCES
EXIT
< 1/5
EXIT
National Building Code of the Philipp
EXIT
MIN OF 1.10 M
Hazardous Areas/ 50 or
more load
DOOR EXIT
National Building Code of the Philipp
NATIONAL BUILDING CODE
OF THE PHILIPPINES
(Mall)
Building Occupancy
• Group E:
▫ Business & Mercantile
5.00m
2.40m
PARALLEL PARKING
2.00m
6.00m
5.00m
2.40m
3.60m
Diagonal Parking
National Building Code of the Philippine
PARKING FOR PWD
1 accessible parking slot for the handicapped per 50 parking lots up to 150
slots and an additional slot for every 100 slots
Maximum distance of accessible parking area from facility served. Parking
areas for the physically handicapped shall be within 60.00m of the facility
being served.
FACILITY SERVED
WALKWAY
5.70m
2.55m to 2.70m
5.70m
2.55m to 2.70m
90 DEG. PARKING
BAY TWO SIDES
45 15.80 5.80 3.90 13.85 4.97 3.90 Pl anning and Designers Handbook (Second Edition)
Max B. Fajardo Jr.
R = 17.00m
to 21.00m
UP
4.00m to DN
4.50m
4.00m to
4.50m
17.60m
2.10m
7.60m
2.70m 3.00m