ENTroubleshoot
CHEMSHIELD PROCESS
BATH LOADING
This is the ratio of work area plated verse the volume of the EN
solution. Optimum situation is 0.5ft 2 of work plated for every gallon of
EN solution.
pH ADJUSTMENT
CLEANING
DUMMY
This term is use as reference for scrap work put into an electroless
nickel solution for the purpose of plating out the impurities and
discarding them in the deposit. Dummying will remove copper, zinc and
some organics.
CARBON TREATMENT
In a separate storage tank, add 1-4 pounds of activated carbon for every
100 gallons of room temperature electroless nickel solution. Filter back
the solution and remove any trace of carbon particles. Caution – first
carbon treat the EN solution in a beaker and test in the lab before
resuming production. Carbon treatment may remove some stablizers.
ADDITIVE ADJUSTMENTS
Do not make a single addition that requires more than a 15% add back.
Addition above this amount should be broken up and put into the bath
during a reasonable time frame. This will depend on the normal usage and
addition rate of the additives.
Technical Service Procedure for ChemShield Products Page 6
Chemtech Finishing Systems, Inc "The information presented herein is our interpretation of certain test results and field experience
23177 Commerce Drive to date. This information is not to be taken as warranty or representation for which we assume
Farmington Hills, MI 48335 legal responsibility, nor as permission or recommendation to practice any patented invention
Telephone: 248-478-5200 without a license. It is offered solely for your consideration, investigation and verification." ©
Fax: 248-478-6810 Chemtech Finishing Systems, Inc.