‫النوتة الحسابية الخاصة بالخوازيق الساندة‬

Design of piled wall

- Ground water level is assumed to be below the foundation level of the


wall and therefore not affecting the soil properties & The wall.

1. Design parameters:

The height to the foundation level = 7.00 m

Soil density: 1.8 t/m3

‫بعد الرجوع إلي تقرير الجسات تبين أن تتابع طبقات التربة بموقع المبني شبه منتظمة وأنها عبارة‬
.‫عن طبقة من الطين الطميي الممتد‬

Angle of internal friction for layers = 0.0

28-days Concrete cube strength= 300 kg/cm2


2.1 Check stress on pile:

the pile is a cantilever pile

t/m2
t/m2
t/m2
By solving 1 & 2 together get D = 1.72 m , L2 = 0.59 m,
F.O.S = 2.0 D = 3.44 m

Total Length of pile = 14.0 m (From Ground Level)


Maximum moment is at zero shear point

M = 2.50*2.02– 7.0*0.3572/2= 4.557m.t

Mu pile = 4.557*0.80*1.5 = 5.469 m.t

Cm2 use 10 16 /pile