Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

UTO_TB1 UTO_TB2 UTO_TB3 UTO_TB16 UTO_TB4 UTO_TB5 UTO_TB14 UTO_TB6

4P/1L 4P/1L 4P/1L 4P/1L 4P/1L 4P/1L 4P/1L 4P/1L


GND GND GND GND +24V +24V GND GND
TB5-4 1 UTO_TB2-1 1 UTO_TB3-1 1 UTO_TB16-1 1 TB2-4 1 UTO_TB5-1 1 TB11-2 1 UTO_TB6-1 1
UTO_TB1-2 2 UTO_TB2-2 2 UTO_TB3-2 2 UTO_TB16-2 2 UTO_TB4-2 2 UTO_TB5-2 2 UTO_TB14-2 2 UTO_TB6-2 2
UTO_TB1-3 3 UTO_TB2-3 3 UTO_TB3-3 3 UTO_TB16-3 3 UTO_TB4-3 3 3 UTO_TB14-3 3 UTO_TB6-3 3
UTO_TB1-4 4 UTO_TB2-4 4 UTO_TB3-4 4 UTO_TB16-4 4 UTO_TB4-4 4 4 UTO_TB14-4 4 UTO_TB6-4 4

J
J

J
1

2
J10 J19 J7
FBS 4-5 FBS 2-5 FBS 2-5

TB10-3
TB10-4
(+24V)
UTO_F1 UTO_TZ1
22
TTC-6-TVSD-D-24DC-PT-I
12 UT 4-L/HESI TO TRAIN MOVEMENT
11 UTO_TB7 UTO_TB9 2 4 2 4 8TMAB_A+ ALERT BEACONS.
14 21 4P/1L 4P/1L
Cad File: Z:\BIM(UGL)\00_Input\Batch E001 PKG6060 Electrical Schematic Drawings\ROAD 8\OUTPUT\SMCSWLWC-SYC-RTF-ED-DWG-239890.dwg

24 1 1
8TMA_DRV1 A1 2 2
3 3 1 3 UTO_TB14-3 1 3 8TMAB_A-
4 4 (GND)
UTO_TB14-2 A2
(GND) UTO_F2 UTO_TZ2
TMA_R1 UT 4-L/HESI TTC-6-TVSD-D-24DC-PT-I

J
RLY_PWR 2 4 2 4 8TMAB_B+
1

2
1 3 UTO_TB14-4 1 3 8TMAB_B-
J11 (GND)
FBS 2-5
UTO_F3 UTO_TZ3
UT 4-L/HESI TTC-6-TVSD-D-24DC-PT-I
2 4 2 4 8TMAB_C+

1 3 UTO_TB6-1 1 3 8TMAB_C-
(GND)
UTO_F4 UTO_TZ4
UT 4-L/HESI TTC-6-TVSD-D-24DC-PT-I
2 4 2 4 8TMAB_D+

TB12-2
TB12-3 1 3 UTO_TB6-2 1 3 8TMAB_D-
(+24V) (GND)
22
12
11 UTO_TZ5
14 21
UTO_F5
Plot Date: 25/02/22 - 13:19

24 UT 4-L/HESI TTC-6-TVSD-D-24DC-PT-I TO TRAIN MOVEMENT


8TMA_DRV2 A1 2 4 2 4 8TMAS_A+ ALERT SOUNDERS.

UTO_TB6-3 A2
(GND) 1 3 UTO_TB6-4 1 3 8TMAS_A-
TMA_R2 (GND)
NOTES:
100mm AT FULL SIZE

RLY_PWR UTO_F6 UTO_TZ6


UT 4-L/HESI TTC-6-TVSD-D-24DC-PT-I 1. RLY_PWR RELAY IS FINDER P/N 48.61.7.024.0050SPA.
2 4 2 4 8TMAS_B+ 2. TRAIN MOVEMENT ALERT BEACONS ARE CONNECTED VIA 4 CABLE RUNS.
3. TRAIN MOVEMENT ALERT SOUNDERS ARE CONNECTED VIA 2 CABLE RUNS.
4. RLY_PWR RELAYS HAVE INTEGRATED FREE-WHEELING DIODES IN PARALLEL WITH COIL.
1 3 UTO_TB16-1 1 3 8TMAS_B- 5. FUSEHOLDERS ARE FITTED WITH A 5A, 5MM x 20MM FUSE (LITTELFUSE 0217005. OR SIMILAR).
(GND)
6. SURGE PROTECTION DEVICES ARE PHOENIX CONTACT TTC-6-TVSD-D-24DC-PT-I, P/N 2906834.
ALTERNATIVE (OBSOLETE) PART IS PHOENIX CONTACT TT-STTB-24, P/N 2858140.
7. FBS 4-5 JUMPERS ARE PHOENIX CONTACT P/N 3030187.

WORK AS EXECUTED
SCALES CLIENT The information shown on this drawing is for the purposes of the Sydney Metro Project only. No warranty is given or implied as to its suitability for any other
NOT TO SCALE
purpose. The Service Providers accept no liability arising from the use of this drawing and the information shown thereon for any purpose other than the Sydney
Metro Project. SYDNEY METRO CITY & SOUTHWEST
SERVICE PROVIDERS RAPID TRANSIT RAIL FACILITY
MARK NORRIS
DRAWN PKG6060 SMTF eFORTRESS KEY SYSTEM (eFKS)
DESIGNED MARK NORRIS ROAD 8 - ELECTRICAL SCHEMATICS
MICHAEL C. CHENG
INTERFACES - UNATTENDED TRAIN OPERATION (UTO)
50 MC 22.02.2022 WORK AS EXECUTED DS DRG CHECK
CCR NO.131293 STATUS: WORK AS EXECUTED
REV. BY DATE DESCRIPTION APPD. DESIGN CHECK MICHAEL C. CHENG SHEET 16 OF 20 C
ALT. DRG No. 410-000-515_1/16 DARREN SLATTERY 22.02.2022 DRG No.SMCSWLWC-SYC-RTF-ED-DWG-239890 REV. 50
A1 Original Co-ordinate System: MGA Zone 56 Height Datum: A.H.D. This sheet may be prepared using colour and may be incomplete if copied NOTE: Do not scale from this drawing. APPROVED