Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Project : Design by :

LOGO Owner :
Location :
Check by : Engr. Mark Christian D. Esguerra
Mark :
Date :
F1
10/2/2022
ISOLATED FOOTING

Material Properties Column Properties: Reinforcement Details:


Concrete f'c = 20.70 Mpa Width = 0.25 m Location #
Reinforcing fy = 414.00 Mpa Height = 0.25 m Bot Bar Dia = 16.00
Location = CenterMid Along x = 9 OK!
Soil Properties: Footing Properties: Along y = 9 OK!

0.25 m
σall= 145.00 kPa Length = 1.70 m Cover (mm) = 75.00

1.7 m
γ= 18.00 kN/m3 Width = 1.70 m
Thickness = 0.35 m 0.25 m
Depth = 1.50 m
Applied forces:
Load Case Pu Mx My Fx Fy
qa factor
Units kN kN.m kN.m kN kN
Service Load = 366.10 15.56 0.02 0.02 16.42 1.33 1.7 m
Factored Load = 422.05 21.81 0.02 0.03 23.03 1.00

Check for Soil Pressures (Service Load) Check for Stability (Service Load)
Location Total Pressure Remark Overturning Sliding
Corner 1= 184.11 kPa x-x y-y
x-x y-y
Corner 2= 132.08 kPa Overturn Resisting Overturn Resisting
Corner 3= 132.02 kPa 21.30 388.28335 0.02 388.28335 Ratio Ratio
Corner 4= 184.05 kPa 18.22644574 15920.77974 11,183.40 15.56
Ratio 0.95 Safe Safe Safe Safe

Check for Shear Design (Factored Load)


132.08 kPa Check Wide Beam Shear Check Punching Shear
-Side +Side Units x-x y-y Unit
132.02 kPa Along x 0.52 0.41 Mpa Unbalance Moment factor = 0.4 0.4
184.11 kPa Along x 0.45 0.45 Mpa Column Location Factor = 40
Absolute max. Stress = 0.52 MPa ColumnAspect Ratio = 1
184.05 kPa Under-strenght φ Factor = 0.75 Actual Punching Stress = 0.84 MPa
Allowable Shear Capacity = 0.58 MPa Allowable Shear Capacity = 1.13 Mpa
3D Zoom In Zoom Out
Ratio 0.897 Safe Ratio 0.74 Safe
Detailed Calculations
Check for Stability (Service Load) Check for Soil Pressure (Service Load) Check for Shear (Factored Load) Check for Reinforcement (Factored Load)
Overturning about x-x Soil Pressure Punching Shear Design of steel
Moment = 15.56 Overturn Mom x-x = 21.30 kN-m Net Ultimate Bottom Reinforcement
Shear Force = 5.75 Resisting Mom x-x = 388.28 kN-m soil pressure at critical point Along x Along y Unit
Total = 21.30 Overturn Mom y-y = 0.02 kN-m Point 1 = 188.38 kPa Mu = 87.83 78.57 kN.m
Resisting about x-x Resisting Mom y-y = 388.28 kN-m Point 2 = 166.49 kPa Ru = 0.856 0.766 MPa
Footing Weight = 20.63 Resisting Force = 456.80 kN Point 3 = 166.47 kPa m= 23.529 23.529
Soil Weight = 64.89 Xp = 0.85 Point 4 = 188.36 kPa req'd p = 0.00212 0.00189
Bouyancy = (8.43) Yp = 0.80 Average = 177.43 kPa min p = 0.00338 0.00338
Axial = 311.18 X-ecc = 0.00 Calculation of unbalanced moment transferred by use p = 0.00283 0.00252
Total = 388.28 Y-ecc = 0.05 eccentricity of shear As = 1,245 1,110 mm2

Ratio 18.23 Pu 6ey 6ex β= 1.00 ACI 11.11.2.1.a req'd n2 = 7.00 6.00 pcs
Formula q= 1± ±
Remark = Safe A B L αs = 40.00 ACI 11.11.2.1.b s (mm) = 169.50 169.50 mm
Overturning about y-y Corner Pressure 1 = 184.11 kPa b1 = 0.51 m
Moment = 0.02 Corner Pressure 2 = 132.08 kPa b2 = 0.51 m
Shear Force = 0.01 Corner Pressure 3 = 132.02 kPa bo = 2.04 m
Total = 0.02 Corner Pressure 4 = 184.05 kPa Critical Area = 0.26 mm2
Resisting about y-y Resultant = 46.13 kN
Footing Weight = 20.63 Check for Shear (Factored Load) γf = 0.60 x-x ACI 13.5.3.2
Soil Weight = 64.89 Wide Beam Shear γf = 0.60 y-y ACI 13.5.3.2
Bouyancy = (8.43) Shear Forces calculated as the volume of γv_x = 0.40 x-x ACI 11.11.7.1
Axial = 311.18 bearing pressures γv_y = 0.40 y-y ACI 11.11.7.1
Total = (9.91) Corner Pressure 1 = 0.520 MPa 𝐽ൗ 0.0956 N/mm2 x-x
𝑐1
Ratio = 15,920.78 Corner Pressure 2 = 0.410 MPa 0.0956 N/mm2 y-y
Remark = Safe Corner Pressure 3 = 0.450 MPa Vu = 0.84 ACI 11.11.5.2.a
Sliding Calculation Corner Pressure 4 = 0.450 MPa φVu = 1.71 ACI 11.11.5.2.b
kp = 2.78 Maximum Stress = 0.520 MPa Calculation of RC punching shear resistance
Pressure mid d = 83.75 without shear reinforcement (φVn = φVc)
Ultimate Shear Capacity
X-Passive Force = 49.83 Vc = φ0.166λ√f'c - ACI 22.5.5.1 Vc (N/mm2) = 2.32 ACI 11.11.2.1.a
Y-Passive Force = 49.83 Reduction factor φ = 0.750 Vc (N/mm2) = 2.67 ACI 11.11.2.1.b
Friction force = 205.56 λ= 1.000 Vc (N/mm2) = 1.50 ACI 11.11.2.1.c
Safe Factor x-x = 11,183.40 Vc = 0.580 MPa φVc (N/mm2) = 1.13
This spreadsheets is licensed only to
Safe Factor y-y = 15.56 Ratio = 0.896 Ratio = 0.743
Engr. Mark Christian D. Esguerra
Remark = Safe Remark = Safe for beam shear! Remark = Safe for punching shear!