® Signal Unit
waciee| NAUTOALARM
Type 135 - 097
OPERATOR MANUAL
‘9214E/195-097,.000012 Eston: 01. Nov. 1999Wetergabe sowie Vevefiiung deer Unteiage, Verwertng und
iting ies hates nicht gett sower nich auscricklch
tugestanden, Zuwiderandurgen verplihten 2 Scadenesat.
Toute communication cu repncuction dec document, tute
‘exlotation ou communicaten de so contenu sont interes st
autorsatin expres. Tout msnqusment et rig est ile et
‘Spore son enw av versa ce danemage tress.
Copying ofthis document andar it tots andthe se or
‘amnuncton ef the contents thereat are forbidden without empress
authori. Ofenders are abl to the payment of damages.
Sin esta exresaautozaci,quedsteminantement profi a
‘reproduc total o parcial deste document, asi come su so
Indebdo plo su edb 0 comaniacn a tercrs. De hs inactres
se eign el coresponcente esarcinent de aes y peesSignal Unit NAUTOALARM
Operator Manual
Tectia
CONTENTS Page
1 General oe. cece 1
2 Operating Instructions 2
24 Notes on the operating instructions . 2
22 Status Indications 3
23 Alarm Indications 4
24 Dimmi 7 5
25 Test 2.2... 5
26 Switching off 5
Exition: 01. Nov. 1898 1 32148/195-097. D0C012Signal Unit NAUTOALARM
Operator Manual
32146/135-097.000012 " Edition: 16. Sept. 1907Signal Unit NAUTOALARM
Operator Manual
Jeotncal
Decumantstion
General
Equipment and units are monitored with the NAUTOALARM signal unit. The unit can dis-
play up to 15 operating conditions or errors. Operating conditions are signalised by means
of a dimmable continuous light, and errors by flashing light and an acoustic signal. The
signal input can either be via voltage or a contact.
Additionally, there are also connections for an external mer and an external reset key. A
relay contact (inverter) is used as external alarm signal keying device (aggregate alarm).
When required, a relay PCB with floating contact can be used for alarm signalisation. The
connection to other attached alarm devices is made via a transfer module. The relay PCB
also has a serial interface for external status messages.
‘When using two spatially separated assembled signal units NAUTOALARM (e.g. bridge
and steering gear room), a master/slave version or a master/master version can be
realized (for Version SAQO1 only partially applicable)
Fig. 1-1: Signal Unit NAUTOALARM, Type 135-097 (Example)
Operator Manual
This operator manual contains all operating instructions as well as a survey of possible
warnings and alarms.
Service Manual
In addition to the operator manual a service manual is available. It contains information
about installation and first putting into operation.
Exton: 01. Nov, 1969 1 32148/195-097.000012Signal Unit NAUTOALARM
Operator Manual
2 Operating Instructions
With switching-on the 24 Vp¢ supply voltage the signal unit NAUTOALARM is put in opera-
tion.
24 Notes on the operating instructions
Explanation of symbols:
OG Key operation
| | Signal or alarm position out
Signal or alarm position on
Alarm position fishing
LED out
LED on
LED flashing
Audible signal on
Audible signal off
82148 /135-097.D00012 2 Edition: 18. Sept. 1997Signal Unit NAUTOALARM
Teerneas
Operator Manual
Documentation
22 Status Indications
Explanation of status indications
display panel has no function
display panel in normal status function
display panel in warning function
display panel in alarm function
Edtion: 18. Sept. 1997 3 32148/195-097.000012Signal Unit NAUTOALARM
Operator Manu:
23 Alarm Indications
7
Indications
Comments,
Notes
‘When an alarm occurs:
~ corresponding display lights up
brightly
alarm-LED flashes red
= acoustic signal is emitted
Version SA001:
@ After activation of the
reset key:
~ corresponding display
lights up brightly
= alarm LED blinks red
= acoustic signal sounds
After alarm is acknowledged:
~ corresponding display lights up
brightly
= alarm-LED lights red (constant
light)
= acoustic signal stops sounding
This indication remains unti the er-
ror has been alleviated.
Version two devices:
Depending on the con-
rections of the devices to
each other, acknowledge-
ment is either at both or
only at one of the units
{for Version SA0O1 only
partially applicable)
s2148/195-087.00C012
Edition: 01, Nov. 1999Signal Unit NAUTOALARM
Operator Manual
Documentation
24 Dimming
Indications
‘Comments,
Notes
or:
continuous brightness adjustment
= of the keys
~ ofthe display
‘The dimmer can not be used
during an acoustic alarm,
25
Indications.
Comments,
Notes
2
a
simultaneously
The self-test runs for approx. 10
secs after pressing the key:
= each of three signal lams lights
Up (vertical) one after the other
from left to right at their brigh-
test setting (displays with no
function remain dark)
= alarm-LED lights up yellow.
The configuration is then dis-
played:
~ Lamps light up brightly in conri-
guration of “normal status” and
*warning’.
Lamps flash bright in “alarm
configuration.
= displays with no function remain
dark
‘The test can not be carried
‘out when the alarm is active.
26 ‘Switching off
The unit is putting out of operation by switching-off the 24 Voc ship’s mains.
Edition: 01. Nov. 1999
'3214E/198-097,.000012Signal Unit NAUTOALARM