ANALYSIS AND RESULTS

Data for the theoretical data of n1 and n2


n1 = 1000

n2 = 500

V2 V1
0,177 1,248
0,326 2,23
0,498 3,34
0,614 4,01
0,818 5,02
1,099 6,01
1,502 7,35
1,795 8,27
2,10 9,40
2,46 10,47
2,55 11,12
3,06 12,36

TABLE 1: Experimental values v1 vs v2


V2 vs V1
14.000
12.36
f(x) = 3.74762583921493 x + 1.42684236326545
12.000 R² = 0.987072409483714 11.12
10.47
10.000 9.4
8.27
8.000 7.35
Voltage (V2)

6.01
6.000
5.02
4.01
4.000 3.34
2.23
2.000 1.248

0.000
0 0.5 1 1.5 2 2.5 3 3.5

Voltage (V1)

Figure 1: Secondary voltage on the unloaded transformer, as a function of the primary voltage.

PENDING EXPERIMENTAL:

m = 3,7476

THEORETICAL PENDING:

n2 500
V2 = =
n1 1000

V2 = 0.5

PERCENTAGE OF ERROR:

0.5−3.7476
E%= X 100
0.5
E%=
I2 I1
10,72 7,16
19,61 12,82
28,8 18,77
34,6 22,0
42,7 27,1
49,7 31,4
57,9 36,7
64,0 40,5
71,3 45,0
78,3 49,2
82,0 51,9
88,9 55,9

TABLE 2: Experimental values I1 vs I2

I2 vs I1
60
f(x) = 0.6233243091477 x + 0.555997664283005
50 R² = 0.99992649264088

40
Current (I2)

30

20

10

0
0 10 20 30 40 50 60 70 80 90 100

Current (I1)

Figure 2: Secondary short – circuit current as a function of the primary current in the transformer.

PENDING EXPERIMENTAL:

m = PENDING EXPERIMENTAL:

m = 0,6233
THEORETICAL PENDING:

n1 100 0
I2 = =
n2 500

I2 = 2

PERCENTAGE OF ERROR:

0.5−3.7476
E%= X 100
0.5
E%=

DATA FOR THE THEORETICAL DATA OF n1 AND n2


n1 = 1000

n2 = 250

V2 V1
0,163 1,061
0,321 2,01
0,556 3,36
0,704 4,19
0,914 5,26
1,093 6,12
1,314 7,17
1,549 8,29
1,783 9,40
1,94 10,27
2,19 11,43
2,42 12,51

TABLE 3: Experimental values v1 vs v2


V2 vs V1

14.000

12.000 f(x) = 5.01077513516677 x + 0.514578671221855


R² = 0.998790422563903
10.000
Voltage (V2)

8.000

6.000

4.000

2.000

0.000
0 0.5 1 1.5 2 2.5 3

Voltage (V1)

Figure 3: Secondary voltage on the unloaded transformer, as a function of the primary voltage.

PENDING EXPERIMENTAL:

m = 5,0108

THEORETICAL PENDING:

n2 25 0
V2 = =
n1 1000

V2 = 0.25

PERCENTAGE OF ERROR:

0.5−3.7476
E%= X 100
0.5
E%=
I2 I1

10,11 4,15
19,1 7,69
31,09 12,41
38,7 14,93
45,6 17,76
49,7 19,3
55,8 22,1
59,2 23,7
64,0 25,8
67,7 27,5
72,6 29,6
76,9 31,5

TABLE 4: Experimental values I1 vs I2

I2 vs I1
35

30 f(x) = 0.409197097312596 x − 0.432573830257347


R² = 0.998067376562541
25
Current (I2)

20

15

10

0
0 10 20 30 40 50 60 70 80 90

Current (I1)

Figure 4: Secondary short – circuit current as a function of the primary current in the transformer.
PENDING EXPERIMENTAL:

m = 0,4092

THEORETICAL PENDING:

n2 100 0
I2 = =
n1 250

I2 = 4

PERCENTAGE OF ERROR:

0.5−3.7476
E%= X 100
0.5
E%=