Professional Documents
Culture Documents
R23 Auditorium
R23 Auditorium
R23 Auditorium
Hence, v. of auditorium , V
= (5.9 X 23.8 X 16.43) - (1164 + 33) = 2308 - 1197 = 1111 m3
RT= (0.16xV)/A
= (0.16 x 1111 ) / 24.12
= 7.36 seconds
PLAN Hence for R.T. 7.36 seconds acoustical conditions are very
bad . hence treatment is required.
Recommended
Sr no. Acoustics
time in seconds
PARTH SABLE
CASE : 2
1. WALL 1 : 9mm thk felt wall overlay (0.08) + 75mm thk
Fiberglass Acoustic Panels (0.99)
Wall 1 has 2 doors of 2.5x1.5m.
A1 = 2308 x 5.9 - 2(2.5 x 1.5) = 133 sq. m.
A1S1 = ( 66 x 0.08 )+ (67x0.99)= 71.61
2. WALL 2 : 9mm thk felt wall overlay (0.08) + 75mm thk
Fiberglass Acoustic Panels (0.99)
Wall 2 has 1 door of 1.7x2.1m and 2 doors of 2.1x1m
A2 = 16.43 x 5.1 -[(1.7 x 2.1)+(2 x 1 x 2.1)] = 76 sq.m.
A2S2 = (38x0.08+(38x0.99) = 40.66
3. WALL 3 : 9mm thk felt wall overlay (0.08) + 75mm thk
Fiberglass Acoustic Panels (0.99)
Wall 3 has 2 doors of 2.5x1.5
A3 = 23.8 X 5.9 - 2(1.5 X 2.5)= 133 sq.m.
A3S3 = (66x0.08) + (67x0.99) = 71.66
4. Wall:4 9mm thk felt wall overlay (0.08)
A4 = 68.43 X 5.3 = 87 sq.m.
A4S4 = 87 X 0.08 = 6.96
5. F1 :9mm thk felt wall overlay (0.08)
F1 = 322 sq.m. X 0.08 = 25.76
6. F2 :Wooden Planks (0.15)
F2 = 55 sq.m. X 0.15 = 8.25
7. C : 75mm thk Sprayed Cellulose Fibre (0.99)
Ceiling = 390 sq.m. X 0.99 = 386
8. Total area = 549.93
RT= (0.16xV)/A
= (0.16 x 1111 ) / 610.9
= 0.291seconds
PLAN Hence for R.T. 0.291 seconds acoustical conditions are very
excellent.
Recommended
Sr no. Acoustics
time in seconds
PARTH SABLE