CAUSE: Code 34 is the cause of the error, code 61 can be a resultant code of the error 34
The information provided on this web site is considered to be confidential information and is intended to assist you in resolving product issues. In addition, the information
on this web site is not to be considered as an authorization for any financial claim against MCFA.
Always follow all Safety, Warning, Caution and Precaution information that is provided in the appropriate Service Manual and Operation and Maintenance Manual(s).
RESOLUTION
When troubleshooting this combination of codes, we suggest that one of the first tests would be the
inverter ohm test. Disconnect the battery, discharge the inverter capacitor as indicated in the Service
Manual (page 1-45). Remove all the cables to the inverter and re-install the nuts on to the POS (F),
NEG, U, V, and W terminals to ensure proper connections inside the inverter. Perform the ohm test
following the manual pages (page 1-62) on checking the inverter.
Note: It is very important to re-install the nuts on the POS (F), NEG, U, V, and W terminals or the
connections inside the inverter will not be made and your readings will not be correct.
CONTROLLER
Rear cover
211414
1-45
CONTROLLER
Checking Inverter
! CAUTION
Disconnect the battery plug and discharge the
inverter before working on electrical system.
Be sure discharging is complete before starting
ohm measurements.
1-62