Professional Documents
Culture Documents
Example CE Marking Door
Example CE Marking Door
Harmonised
Essential Characteristics Declared performance
Standard
Watertightness Class 3A (100Pa)
Dangerous Substances None
Resistance to wind load
Test Pressure Class 2 (800Pa)
Frame deflection Class A (< 1/150)
Load bearing capacity of
Not Applicable
safety device EN 14351:2006 +
2
Thermal transmittance 1.6 W/(m .K) A1:2010
Ability to release Pass
Height and Width >1950mm, >870mm
Acoustic performance NPD
Radiation properties
Solar gain NPD
Light transmittance NPD
Air permeability Class 2 (300Pa)
Type testing conducted by and EC certificate issued by 0086
Intended for use: On escape route