Villa U-Value Calculator (Temporary Program)

Walls

Overview Wall U-value Roof U-value Materials Glossary Summary

Performance Calculation Method: 0

EVPD Reference Construction U- Total Area of


Number of EVPD constructions: EVPD Wall Type Description
Number value (W/m².K) Construction (m²)
0 1 Target Average U-value: 0.570 W/m².K
2 Average U-value for all walls: 0.274 W/m².K
3 Average U-value Passes RE-R1 Target
4

Entering the required information will enable calculation of the wall U-value. The Category and Material for each layer can be selected and the thickness varied to match the proposed design. Variations in material properties
can be achieved via the materials tab, once they have been entered below. Any material not in the database should be entered as "Miscellaneous", "Other" and the Thermal Conductivity defined in the Materials tab. Full
supporting documentation should also be provided.

Number of non-EVPD constructions: Internal Design Temperature Surface Finish


1 24°C Light

Thermal Thermal
Non-EVPD Wall Description: Layer Thickness Conductivity, k Resistance, R
(m) (W/m.K) (m2.K/W)
2
Category Material 0.050 m .K/W External Surface Resistance
Cement/plaster/mortar plaster, 800kg/m3 Cement/plaster/mortarplaster,
0.020
800kg/m3 0.220 0.091
Masonry autoclaved aerated concrete block Masonryautoclaved aerated concrete
0.300 block 0.091 3.297 Outside
Cement/plaster/mortar plaster, 800kg/m3 Cement/plaster/mortarplaster,
0.020
800kg/m3 0.220 0.091
to

Inside

2
0.127 m .K/W Internal Surface Resistance

Construction Area 1000.0 m² 3.479


Construction Thickness 0.340 m
2
Total Thermal Resistance 3.656 m .K/W Average U-value for all walls: 0.274W/m².K
2
Element U-value 0.274 W/m .K Average U-value Passes RE-R1 Target