** ON A/C ALL
TASK 24-00-00-810-818-A
Computer Reset
1. Possible Causes
2. Fault Confirmation
Subtask 24-00-00-710-059-A
A. Test
(1) Not applicable
3. Fault Isolation
Subtask 24-00-00-865-051-A
A. Table of the circuit breakers used in this procedure:
** ON A/C ALL
Subtask 24-00-00-810-069-A
B. Computer reset procedure
NOTE: This reset procedure is used when a computer does not operate correctly.
NOTE: The line maintenance personnel can use it a first time to avoid a computer replacement (a reset must
be done for the applicable computer as indicated in the Computer Reset Table).
But, if there is more than one reset for each flight cycle for a given computer, it is necessary to do the
specific troubleshooting procedure for the applicable system.
If after a reset, the computer operates correctly, no more action is necessary.
** ON A/C 001-050, 053-099, 201-203, 211-215, 220-223, 225-227, 301-304, 306-308, 501-502
Subtask 24-00-00-810-075-C
C. Air Conditioning
(1) Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE
21 CAB PR SYS 1(2) FAULT CABIN For CPC 1:
PRESSURE - On panel 49VU, open the
CONTROLLER circuit breaker 1HL.
(CPC) 1(2) FOR CPC 2:
- On panel 122VU, open the
circuit breaker 2HL.
After five seconds, close the
circuit breaker.
21 COND ZONE REGUL FAULT ZONE On panel 122VU:
TEMPERATURE - Open the circuit breaker 1HK.
CONTROLLER - Open the circuit breaker 2HK.
After five seconds, close the
circuit breaker.
21 AIR FWD (AFT) CRG VENT CARGO On panel 49VU:
FAULT VENTILATION - Open the circuit breaker 31HN.
CONTROLLER After five seconds, close the
circuit breaker.
21 VENT AVNCS SYS FAULT AVIONICS On panel 122VU:
EQUIPMENT - Open the circuit breaker 3HQ.
VENTILATION After five seconds, close the
COMPUTER circuit breaker.
21 AIR PACK 1(2) REGUL FAULT PACK For the PC 1:
CONTROLLER - On panel 122VU, open
(PC) 1(2) then close the circuit breaker 2HH.
For the PC 2:
- On panel 122VU, open
then close the circuit breaker 22HH.
Subtask 24-00-00-810-075-E
C. Air Conditioning
(1) Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE
21 CAB PR SYS 1(2) FAULT CABIN For CPC 1:
PRESSURE - On panel 49VU, open the
CONTROLLER circuit breaker 1HL.
(CPC) 1(2) FOR CPC 2:
- On panel 122VU, open the
circuit breaker 2HL.
After five seconds, close the
circuit breaker.
21 AIR FWD (AFT) CRG VENT CARGO On panel 49VU:
FAULT VENTILATION - Open the circuit breaker 31HN
CONTROLLER After five seconds, close the
circuit breaker.
21 VENT AVNCS SYS FAULT AVIONICS On panel 122VU:
EQUIPMENT - Open the circuit breaker 3HQ.
VENTILATION After five seconds, close the
COMPUTER circuit breaker.
21 AIR PACK 1(2) REGUL FAULT AIR COND For the ACSC 1:
SYSTEM - On panel 122VU, open
CONTROLLER the circuit breaker 49HH,
(ACSC) 1(2) circuit breaker 50HH
and circuit breaker 51HH.
- On panel 49VU, open
the circuit breaker 52HH.
Then close the circuit breakers.
For the ACSC2:
- On panel 122VU, open
the circuit breaker 53HH,
circuit breaker 54HH,
circuit breaker 55HH and
circuit breaker 56HH.
Then close the circuit breakers.
21 COND AFT CRG HEAT FAULT AFT CARGO On panel 49VU:
HEAT - Open the circuit breaker 31HN.
CONTROLLER - After five seconds, close
the circuit breaker.
** ON A/C ALL
Subtask 24-00-00-810-076-A
D. Auto Flight
(1) Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE
22 AUTO FLT YAW DAMPER 1(2) FAC1(2) Open these C/Bs with the
FAULT Yellow and Green hydraulic
systems pressurized:
- for the FAC 1: on the
panel 49VU, C/B 5CC1
- for the FAC 2: on the
panel 121VU, C/B 5CC2
Then close the C/Bs after 10
seconds.
22 WINDSHEAR DET FAULT or FAC 1+2 Open then close the C/Bs in
REAC W/S DET FAULT this the order:
- on the panel 49VU, C/B
5CC1 and C/B 14CC1
- on the panel 121VU, C/B
5CC2 and C/B 14CC2.
22 AUTO FLT FCU 1(2) FAULT FCU For the FCU1:
- on the panel 49VU, open
the C/B 9CA1.
For the FCU2:
- on the panel 121VU, open
the C/B 9CA2.
Close the C/B after 5
seconds.
If the fault does not
continue, do a check of the
target and barometer
references shown, and
correct them if necessary
(reset successful).
If the fault continues, open
again the two C/Bs 9CA1
on 49VU and 9CA2 on 121VU.
Close the C/Bs after 7 min,
with an interval less than
5 sec between side 1 and
side 2.
At least 30 sec are necessary
until the end of the FCU1
and FCU2 safety test.
If the fault does not
continue, do a check of the
target and barometer
references shown, and
correct them if necessary
(reset successful)
If the fault continues, end
of procedure (reset
unsuccessful).
22 One MCDU locked or blank MCDU Open then close the C/B of
Subtask 24-00-00-810-077-A
E. Communications
(1) Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE
23 COM CIDS 1+2 FAULT CIDS - Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
- After 10 seconds, close
the C/Bs in this order:
151RH, 150RH.
23 Uncommanded EVAC horn CIDS Press the EVAC/HORN SHUT
actuation OFF switch.
If unsuccessful:
- Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
- After 10 seconds, close
the C/Bs in this order:
151RH, 150RH.
23 Frozen RMP RMP You must do a reset of all
the RMPs, one after the
other.
On the RMP control panel:
- set the ON/OFF switch to
OFF
- after 5 seconds, set the
Subtask 24-00-00-810-077-B
E. Communications
(1) Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE
23 COM CIDS 1+2 FAULT CIDS - Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
on the panel 49VU, C/B 157RH
on the panel 121VU, C/B
156RH
- After 10 seconds, close
the C/Bs in this order:
156RH, 157RH, 151RH and
150RH.
23 Uncommanded EVAC horn CIDS Press the EVAC/HORN SHUT
actuation OFF switch.
If unsuccessful:
- Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
on the panel 49VU, C/B 157RH
on the panel 121VU, C/B
156RH
- After 10 seconds, close
the C/Bs in this order:
156RH, 157RH, 151RH and
150RH.
23 Frozen RMP RMP You must do a reset of all
the RMPs, one after the
other.
On the RMP control panel:
- set the ON/OFF switch to
OFF
** ON A/C 401-499
Subtask 24-00-00-810-077-C
E. Communications
(1) Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE
23 COM CIDS 1+2 FAULT CIDS - Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
- After 10 seconds, close
the C/Bs in this order:
151RH, 150RH.
23 Uncommanded EVAC horn CIDS Press the EVAC/HORN SHUT
actuation OFF switch.
If unsuccessful:
- Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
- After 10 seconds, close
the C/Bs in this order:
151RH, 150RH.
23 Frozen RMP RMP You must do a reset of all
the RMPs, one after the
other.
On the RMP control panel:
- set the ON/OFF switch to
OFF
- after 5 seconds, set the
ON/OFF switch to ON.
23 Frozen FAP Tape Open the C/Bs in this order:
reproducer On the panel 49VU, CB 171RH
On the panel 121VU, CB
170RH
- After 10 seconds, close
Subtask 24-00-00-810-077-D
E. Communications
(1) Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE
23 COM CIDS 1+2 FAULT CIDS - Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
on the panel 49VU, C/B 157RH
on the panel 121VU, C/B
156RH
- After 10 seconds, close
the C/Bs in this order:
156RH, 157RH, 151RH and
150RH.
23 Uncommanded EVAC horn CIDS Press the EVAC/HORN SHUT
actuation OFF switch.
If unsuccessful:
- Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
on the panel 49VU, C/B 157RH
on the panel 121VU, C/B
156RH
- After 10 seconds, close
the C/Bs in this order:
156RH, 157RH, 151RH and
150RH.
23 Frozen RMP RMP You must do a reset of all
the RMPs, one after the
other.
On the RMP control panel:
- set the ON/OFF switch to
OFF
- after 5 seconds, set the
ON/OFF switch to ON.
23 Frozen FAP FAP Open the C/Bs in this order:
Subtask 24-00-00-810-091-A
F. Satellite Communications
(1) Computer reset table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE
23 COM SATCOM FAULT SDU On the panel 121VU:
- Open the C/B 102RV1.
- After 10 seconds, close
the C/B.
** ON A/C ALL
Subtask 24-00-00-810-088-A
G. Electrical Power
(1) Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE
24 GPU cannot be connected GAPCU If at least one power source
to the aircraft (IDG 1 or IDG 2, APU GEN or
batteries) is connected to
the electrical network of
the aircraft:
- On the ELEC control panel
35VU:
. Push and release the
EXT PWR pushbutton
switch.
If no power source is
connected to the electrical
network of the aircraft:
- On the ELEC control panel
35VU:
. Push the BAT 1 and BAT 2
pushbutton switches
(the OFF legend goes
off).
** ON A/C 001-050, 053-099, 201-203, 211-215, 220-223, 225-227, 301-304, 306-308, 501-502
Subtask 24-00-00-810-078-A
H. Fire Protection
(1) Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE
26 SMOKE LAV + CRG DET FAULT SDCU On the panel 49VU:
- open the C/B 11WQ
On the panel 122VU:
- open the C/B 12WQ
After 10 seconds, close the
two C/B's.
26 ENG1(2) LOOP k FAULT ENGINE FDU On the panel 49VU:
- For ENG1 FDU, open the
C/B 7WD1.
- For ENG2 FDU, open the
C/B 8WD2.
On the panel 121VU:
- For ENG1 FDU, open the
C/B 8WD1.
- For ENG2 FDU, open the
C/B 7WD2.
- After 5 seconds, close
the C/Bs.
26 APU FIRE LOOP k FAULT APU FDU On the panel 121VU:
- Open the C/Bs 2WG and 1WG.
- After 5 seconds, close the
C/Bs.
** ON A/C ALL
Subtask 24-00-00-810-079-A
J. Flight Controls
(1) Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE
27 F/CTL ELAC 1(2) FAULT ELAC Reset the defective ELAC:
F/CTL ALTN LAW FAULT - Make sure that the
hydraulic systems are
depressurized before the
reset.
- Set the ELAC pushbutton
switch to OFF, then to ON.
27 ELAC or SEC malfunction ELAC or SEC Reset the defective ELAC:
- Make sure that the
hydraulic systems are
depressurized before the
reset.
Open, then close the C/B of
the defective ELAC or SEC.
2SN2.
- After 5 seconds, close
the C/Bs.
34 NAV RA 1(2) FAULT XCVR-RA On the panel 121VU:
- For XCVR-RA 1, open the
C/B 1SA1.
- For XCVR-RA 2, open the
C/B 1SA2.
- After 5 seconds, close
the C/Bs.
** ON A/C 001-050, 053-099, 201-203, 211-215, 220-223, 225-227, 301-304, 306-308, 501-502
Subtask 24-00-00-810-084-A
Q. Water/Waste
(1) Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE
38 Fault messages on the Vacuum On the panel 2001VU:
FAP in the cabin System - open the C/B 35MG
Controller - after 30 seconds, close
the C/B.
Subtask 24-00-00-810-085-A
R. Information Systems
(1) Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE
46 ATSU malfunction ATSU On the rear circuit
breaker panel 121VU:
- Open the C/Bs in this
order: 3TX1 and 5TX1.
- After 5 seconds, close
the C/Bs in this order:
5TX1 and 3TX1.
** ON A/C ALL
Subtask 24-00-00-810-086-A
S. Engine
(1) Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE
70 ENG IGN A+B FAULT FADEC and On the panels 49VU and 121VU
EIU open then close the C/B of
70 ENG 1(2) FADEC A(B) FAULT FADEC - For the FADEC 1, C/Bs
2KS1 and 4KS1.