Professional Documents
Culture Documents
Catalogue Wilson Cables-1
Catalogue Wilson Cables-1
3 FASTER
TIMES
EXPERIENCE
IN CABLE
MANUFACTURE
WILSON CABLES
CABLE MANUFACTURE
ABOUT US
WILSON CABLES
CABLE MANUFACTURE
ABOUT US
Vision
To be the best leading cable
company in Indonesia
Mission
1. Directly addresing the need of our customers
2. Continuous improvement of existing products
3. Modernizing production process to create efficiency
4. Distribution channel throughout Indonesia
5. Product reliability and prompt delivery
6. Human resources development
Value
Customers satisfaction
Always proactive
Be responsible
Learn to improve and innovate
Extra discipline and honesty
WILSON CABLES
CABLE MANUFACTURE
CERTIFICATE
• SMK3
(Sistem Manajemen
Keselamatan dan Kesehatan Kerja)
• APKABEL
(Asosiasi Pabrik Kabel Indonesia)
WILSON CABLES
CABLE MANUFACTURE
PRODUCT CERTIFICATION
WILSON CABLES
CABLE MANUFACTURE
PRODUCT CERTIFICATION
595.276
WILSON CABLES
CABLE MANUFACTURE
ADVANTAGES
High Professional
Technology Service
WILSON CABLES
THE LEADING CABLE MANUFACTURERS
Premium Affordable
Product Price
WILSON CABLES
CABLE MANUFACTURE
PRODUCT
BUILDING
AUDIO CABLE
CABLE
WELDING
CABLE
AUTOMOTIVE
CABLE WILSON CABLES
CABLE MANUFACTURE
BUILDING
CABLE
BUILDING CABLE
CONDUCTOR INSULATION
Nominal Current
Overal Cable Short Circuit
Cross Carrying Capacity
Diameter Weight Nominal DC Insulation Current at
Section Area at 30oC
Cross Resistant at Resistance at 1 Sec
Section Area 20oC 70oC
Approximity Approximity Approximity In Pipe In Air
mm 2
Min. (mm) Max. (mm) kg/km mm 2
Max. (Ω/km) Min. (MΩ.km) Max. A Max. A Max. (kA)
1.5 2.6 3.2 20.27 1.5 12.1 0.011 15 24 0.17
2.5 3.2 3.9 32.05 2.5 7.41 0.010 19 32 0.29
4 3.6 4.4 47.79 4 4.61 0.0085 25 42 0.46
6 4.1 5.0 67.52 6 3.08 0.0007 33 54 0.69
10 5.3 6.4 111.79 10 1.83 0.00065 45 73 1.15
CONSTRUCTION PERFORMANCE
Copper Conductor
Insulation
Special Features
3 FASTER
TIMES
WILSON CABLES
CABLE MANUFACTURE
BUILDING CABLE
CONDUCTOR INSULATION
Nominal Current
Cross
Overal Cable Carrying Capacity Short Circuit
Diameter Weight Nominal DC Insulation Current at
Section Area
Cross Resistant at Resistance at
at 30oC 1 Sec
Section Area 20oC 70oC
Approximity Approximity Approximity In Pipe In Air
mm 2
Min. (mm) Max. (mm) kg/km mm 2
Max. (Ω/km) Min. (MΩ.km) Max. A Max. A Max. (kA)
0.5 1.9 2.3 9 0.5 36 0.015 2.5 - 0.07
0.75 2.1 2.5 12 0.75 24.5 0.012 7 15 0.10
1.0 2.2 2.7 16 1 18.1 0.011 11 19 0.13
CONSTRUCTION PERFORMANCE
Copper Conductor
Insulation
Special Features
PUT OUT THE FIRE
3 FASTER
TIMES
CONSTRUCTION PERFORMANCE
Copper Conductor
Insulation
Special Features
PUT OUT THE FIRE
3 FASTER
TIMES
WILSON CABLES
CABLE MANUFACTURE
BUILDING CABLE
CONDUCTOR INSULATION
Nominal Current
Cross
Overal Cable Carrying Capacity Short Circuit
Diameter Weight Nominal DC Insulation Current at
Section Area
Cross Resistant at Resistance at
at 30oC 1 Sec
Section Area 20oC 70oC
Approximity Approximity Approximity In Pipe In Air
mm 2
Min. (mm) Max. (mm) kg/km mm 2
Max. (Ω/km) Min. (MΩ.km) Max. A Max. A Max. (kA)
0.5 2.1 2.5 9.8 0.5 39.0 0.013 2.5 - 0.06
0.75 2.2 2.7 12.5 0.75 26.0 0.011 7 15 0.09
1 2.4 2.8 15.2 1 19.5 0.010 11 19 0.12
CONSTRUCTION PERFORMANCE
Copper Conductor
Insulation
Available Colour :
Features
• 99.99 % Pure Cooper Conductor
• Easy Installation
• Glossy Finishing Insulation
• Flexibility
Special Features
PUT OUT THE FIRE
3 FASTER
TIMES
Read the cables refrence
WILSON CABLES
CABLE MANUFACTURE
at the end of the catalouge page
BUILDING CABLE
CABLE SPESIFICATIONS
CONDUCTOR INSULATION
Nominal Current
Cross
Overal Cable Carrying Short Circuit
Section Area
Diameter Weight Nominal DC Insulation Capacity Current at
Cross Resistant at Resistance at
at 30oC
1 Sec
Section Area 20oC 70oC
Approximity Approximity Approximity In Air
mm2 mm kg/km mm2 Max. (Ω/km) Min. (MΩ.km) Max. A Max. (kA)
2 x 1.5 8.6 116 1.5 12.1 0.011 19 0.17
2 x 2.5 9.6 149 2.5 7.41 0.010 25 0.29
2x4 11 191 4 4.61 0.0085 34 0.46
2x6 12 250 6 3.08 0.0070 44 0.69
2 x 10 15.2 411 10 1.83 0.0070 61 1.15
3 x 1.5 8.8 135.0 1.5 12.1 0.011 19 0.17
3 x 2.5 10 182.3 2.5 7.41 0.010 25 0.29
3x4 11.6 242.3 4 4.61 0.0085 34 0.46
3x6 12.7 326.5 6 3.08 0.0070 44 0.69
3 x 10 16.5 545.5 10 1.83 0.0070 61 1.15
4 x 1.5 9.6 163.9 1.5 12.1 0.011 19 0.17
4 x 2.5 11.0 237.9 2.5 7.41 0.010 25 0.29
4x4 12.5 334.5 4 4.61 0.0085 34 0.46
4x6 14.0 405.4 6 3.08 0.0070 44 0.69
4 x 10 17.5 701.9 10 1.83 0.0070 61 1.15
WILSON CABLES
CABLE MANUFACTURE
BUILDING CABLE
CONSTRUCTION PERFORMANCE
Copper Conductor
PVC Filler
PVC Sheath
Insulation
Copper Conductor
PVC Filler
PVC Sheath
Insulation
Copper Conductor
PVC Filler
PVC Sheath
Insulation
CABLE SPESIFICATIONS
CONDUCTOR INSULATION
Nominal Current
Cross
Overal Cable Carrying Short Circuit
Section Area
Diameter Weight Nominal DC Insulation Capacity Current at
at 30oC
Cross Resistant at Resistance at 1 Sec
Section Area 20oC 70oC
Approximity Approximity Approximity In Air
mm2 mm kg/km mm2 Max. (Ω/km) Min. (MΩ.km) Max. A Max. (kA)
2 x 0.75 6.7 63.06 0.75 26.0 0.011 6 0.10
2 x 1.0 6.9 67.95 1.0 19.5 0.010 10 0.13
2 x 1.5 7.4 86.30 1.5 13.3 0.010 15 0.19
2 x 2.5 9.2 136.18 2.5 7.98 0.009 20 0.132
3 x 0.75 7.0 73.20 0.75 26.0 0.011 6 0.10
3 x 1.0 7.2 82.23 1.0 19.5 0.010 10 0.13
3 x 1.5 8.2 120.70 1.5 13.3 0.010 15 0.19
3 x 2.5 9.6 166.85 2.5 7.98 0.009 20 0.32
4 x 0.75 7.7 90.94 0.75 26.0 0.011 6 0.10
4 x 1.0 7.8 100.08 1.0 19.5 0.010 10 0.13
4 x 1.5 9.0 154.70 1.5 13.3 0.010 15 0.19
4 x 2.5 10.5 225.60 2.5 7.98 0.009 20 0.132
CONSTRUCTION PERFORMANCE
Copper Conductor
PVC Sheath
Insulation
WILSON CABLES
CABLE MANUFACTURE
BUILDING CABLE
Copper Conductor
PVC Sheath
Insulation
Copper Conductor
PVC Sheath
Insulation
CONDUCTOR INSULATION
Current
Nominal
Cross
Overal Cable Carrying Short Circuit
Section Area
Diameter Weight Nominal DC Insulation Capacity Current at
Cross Resistant at Resistance at at 30oC 1 Sec
Section Area 20oC 70oC
Approximity Minimum Maximum Approximity In Air
mm 2
mm 2
mm kg/km mm 2
Max. (Ω/km) Min. (MΩ.km) Max. A Max. (kA)
0.75 3.7 x 6.0 4.5 x 7.2 73.20 0.75 26.0 0.011 6 0.10
1.0 3.9 x 6.2 4.7 x 7.5 82.23 1.0 19.5 0.010 10 0.13
CONSTRUCTION PERFORMANCE
Copper Conductor
PVC Sheath
Insulation
CONDUCTOR INSULATION
Nominal Current
Cross
Overal Cable Carrying Short Circuit
Section Area
Diameter Weight Nominal DC Insulation Capacity Current at
Cross Resistant at Resistance at at 30oC 1 Sec
Section Area 20oC 70oC
Approximity Approximity Approximity In Air
mm 2
Min. (mm) Max. (mm) kg/km mm 2
Max. (Ω/km) Min. (MΩ.km) Max. A Max. (kA)
0.5 3.0 x 4.9 3.7 x 5.9 30.1 0.5 39 0.012 2.5 0.07
0.75 3.2 x 5.2 3.8 x 6.3 37.16 0.75 26 0.010 6 0.10
CONSTRUCTION PERFORMANCE
Copper Conductor
PVC Sheath
Insulation
CONDUCTOR INSULATION
Nominal Current
Cross
Overal Cable Carrying Short Circuit
Section Area
Diameter Weight Nominal DC Insulation Capacity Current at
Cross Resistant at Resistance at
at 30oC
1 Sec
Section Area 20oC 70oC
Approximity Approximity Approximity In Air
mm2 Min. (mm) Max. (mm) kg/km mm2 Max. (Ω/km) Min. (MΩ.km) Max. A Max. (kA)
2 x 0.5 4.6 5.9 39.22 0.5 39 0.012 2.5 0.07
2 x 0.75 4.9 6.3 48.22 0.75 26 0.010 6 0.10
3 x 0.5 4.9 6.3 48.22 0.5 39 0.012 2.5 0.07
3 x 0.75 5.2 6.7 59.60 0.75 26 0.010 6 0.10
CONSTRUCTION PERFORMANCE
Copper Conductor
PVC Sheath
Insulation
Copper Conductor
PVC Sheath
Insulation
CABLE SPESIFICATIONS
CONDUCTOR INSULATION
Nominal Current
Cross
Overal Cable Carrying Capacity Short Circuit
Diameter Weight Nominal DC Insulation Current at
Section Area at 30oC
Cross Resistant at Resistance at 1 Sec
Section Area 20oC 70oC
Approximity Approximity Approximity In Air In Ground
mm2 mm kg/km mm2 Max. (Ω/km) Min. (MΩ.km) Max. A Max. A Max. (kA)
2 x 1.5 11.2 186.99 1.5 12.1 50 21 27 0.17
2 x 2.5 12.9 256.34 2.5 7.41 50 29 36 0.29
2x4 14.0 315.20 4 4.61 50 38 47 0.46
2x6 14.4 362.87 6 3.08 50 48 59 0.69
2 x 10 16.8 527.63 10 1.83 50 66 78 1.15
3 x 1.5 12.1 186.99 1.5 12.1 50 18 24 0.17
3 x 2.5 12.9 256.34 2.5 7.41 50 25 32 0.29
3x4 14.9 315.20 4 4.61 50 34 41 0.46
3x6 15.9 362.87 6 3.08 50 44 52 0.69
3 x 10 17.7 527.63 10 1.83 50 60 69 1.15
4 x 1.5 12.8 255.85 1.5 12.1 50 18 24 0.17
4 x 2.5 13.8 322.93 2.5 7.41 50 25 32 0.29
4x4 16.0 433.35 4 4.61 50 34 41 0.46
4x6 17.2 553.35 6 3.08 50 44 52 0.69
4 x 10 19.1 774.39 10 1.83 50 60 69 1.15
WILSON CABLES
CABLE MANUFACTURE
BUILDING CABLE
CONSTRUCTION PERFORMANCE
Copper Conductor
PVC Filler
PVC Sheath
Insulation
Copper Conductor
PVC Filler
PVC Sheath
595.276
Insulation
Copper Conductor
PVC Filler
PVC Sheath
Insulation
CONDUCTOR INSULATION
Maximum
Outside Conductor
Nominal
Overal
Calculated Outside Thickness of
Diameter Resistance
Length
Cross
Diameter
Sectional Diameter Vinyl
Approx. ( 20oC )
/ Coil
Section Area Area approx. Insulator
(AxB)
CONSTRUCTION PERFORMANCE
Copper Conductor
Insulation
WILSON CABLES
CABLE MANUFACTURE
AUDIO CABLE
CONDUCTOR INSULATION
N/mm mm m
2 x 20 20/0.12 2.8 100 or 500
2 x 30 30/0.12 3 100 or 500
2 x 40 40/0.12 3.2 100 or 500
2 x 50 50/0.12 3.3 100 or 500
2 x 60 60/0.12 3.4 100 or 500
2 x 80 80/0.12 3.8 100 or 500
2 x 100 100/0.12 3.9
595.276
100 or 500
2 x 120 120/0.12 4.2 100 or 500
CONSTRUCTION PERFORMANCE
Copper Conductor
Insulation
CONSTRUCTION PERFORMANCE
Copper Conductor
Shield Conductor
PVC Sheath
Insulation
Copper Conductor
Shield Conductor
PVC Sheath
Insulation
Features
• 99.99 % Pure Cooper Conductor
• Easy Installation
• Digital Printing Marking / m’
• Glossy Finishing Insulation
• Flexibility
N/mm mm mm N/mm mm mm m
2C x 10/0.12 0.18 0.8 38/0.12 0.48 2.8 100 / 500
CONSTRUCTION PERFORMANCE
Copper Conductor
Shield Conductor
PVC Sheath
Insulation
Features
• 99.99 % Pure Cooper Conductor
• Easy Installation
• Digital Printing Marking / m’
• Glossy Finishing Insulation
• Flexibility
FINISHED OVERALL
CONDUCTOR DATA DIAMETER
Maximum
No. of Thickness Conductor Length /
Nominal Component Calculated Outside of vinyl Resistance Coil
Cross Wires/Dia of Sectional Diameter Insulator Standard Maximum (20ºC)
Section Area Component Area Approx
Wires
mm2 mm mm mm mm mm mm Ω/m m
*0.3 7/0.26 0.372 0.8 0.5 1.8 2 0.050
*0.3f 15/0.18 0.382 0.8 0.5 1.8 2 0.049
0.5 7/0.32 0.563 1 0.6 2.2 2.4 0.033 1000
0.5f 20/0.18 0.509 1 0.6 2.2 2.4 0.037
0.75f 30/0.18 0.763 1.2 0.6 2.4 2.6 0.024
0.85 11/0.32 0.885 1.2 0.6 2.4 2.6 0.021
*0.85f 33/0.18 0.840 1.2 0.6 2.4 2.6 0.022
1.25 16/0.32 1.287 1.5 0.6 2.7 2.9 0.014
1.25f 50/0.18 1.273 1.5 0.6 2.7 2.9 0.015 500
*1.5f 48/0.20 1.508 1.6 0.7 3 3.3 0.012
2 26/0.32 2.091 1.9 0.6 3.1 3.4 0.008
*2f 37/0.26 1.964 1.8 0.6 3 3.4 0.010
3 41/0.32 3.297 2.4 0.7 3.8 4.1 0.006
200
5 65/0.32 5.228 3 0.8 4.6 4.9 0.004
8 50/0.45 7.952 3.7 0.9 5.5 5.8 0.002 100
* : Customer requirement
CONSTRUCTION PERFORMANCE
Copper Conductor
Insulation
Copper Conductor
Insulation
WILSON CABLES
CABLE MANUFACTURE
AUTOMOTIVE CABLE
FINISHED OVERALL
CONDUCTOR DIAMETER
Maximum
No. of Thickness Conductor Length /
Nominal Component Calculated Outside of vinyl Resistance Coil
Cross Wires/Dia of Sectional Diameter Insulator Standard Maximum (20ºC)
Section Area Component Area Approx
Wires
CONSTRUCTION PERFORMANCE
Copper Conductor
Insulation
Copper Conductor
Insulation
Maximum
No. of Thickness Conductor Length
Nominal Component Calculated Outside of vinyl Resistance / Coil
Cross Wires/ Dia of Sectional Diameter Insulator Standard Maximum (20 ºC)
Section Area Component Area Approx
Wires
v Ring Mark for Size : 0.3 & 0.85 Sqmm = Two ring mark
0.5 & 1.25 Sqmm = One ring mark
v Combination between letter mark and dot mark : for size 0.3f , 0.5f , 0.75f , 1.25f Sqmm
v Letter Mark for Size : 0.85f, 2f & 2 Sqmm
CONSTRUCTION PERFORMANCE
B ( Approx 3 mm ) C ( Approx 2 mm )
WILSON AVSS 0.3f LF Combination between letter mark and dot mark
For Size : 0.3f , 0.75f
WILSON CABLES
CABLE MANUFACTURE
AUTOMOTIVE CABLE
Type : AVSSBf
Code Name : -
Standard : HES 3212Z - GHA - 6000 ( Low Voltage Electric Wire for Automobile )
Application : This PVC insulated single-core cable is used for
low voltage circuits in motorcylcles
FINISHED OVERALL
CONDUCTOR DATA DIAMETER
Maximum
No. of Thickness Conductor Length /
Nominal Component Calculated Outside of vinyl Resistance Coil
Cross Wires/Dia of Sectional Diameter Insulator Standard Maximum (20ºC)
Section Area Component Area Approx
Wires
CONSTRUCTION PERFORMANCE
Copper Conductor
Insulation
Available Colour :
Features
• 99.99 % Pure Cooper Conductor
• Easy Installation
• Glossy Finishing Insulation
• Flexibility
Or available custom colour
Type : EB
Code Name : -
Standard : JASO D 611 - 2008 ( Automotive Parts - Unscreened Low-Voltage Cables )
Application : This PVC insulated single-core cable is used for
low voltage circuits in automobiles, vehicles and motorcylcles
FINISHED OVERALL
CONDUCTOR DATA DIAMETER
Maximum
No. of Thickness Conductor Length /
Nominal Component Calculated Outside of vinyl Resistance Coil
Cross Wires/Dia of Sectional Diameter Insulator Standard Maximum (20ºC)
Section Area Component Area Approx
Wires
CONSTRUCTION PERFORMANCE
Copper Conductor
Insulation
Features
• 99.99 % Pure Cooper Conductor
• Easy Installation
• Glossy Finishing Insulation
• Flexibility
WILSON CABLES
CABLE MANUFACTURE
AUTOMOTIVE CABLE
Type : HEB
Code Name : -
Standard : JASO D 611 - 2008 ( Automotive Parts - Unscreened Low-Voltage Cables )
Application : This PVC insulated single-core cable is used for
low voltage circuits in automobiles, vehicles and motorcylcles
FINISHED OVERALL
CONDUCTOR DATA DIAMETER
Maximum
No. of Thickness Conductor Length /
Nominal Component Calculated Outside of vinyl Resistance Coil
Cross Wires/Dia of Sectional Diameter Insulator Standard Maximum (20ºC)
Section Area Component Area Approx
Wires
CONSTRUCTION PERFORMANCE
Copper Conductor
Insulation
Features
• 99.99 % Pure Cooper Conductor
• Easy Installation
• Glossy Finishing Insulation
• Flexibility
CONSTRUCTION PERFORMANCE
Copper Conductor
PVC Sheath
Rubber Synthetic
CONDUCTOR INSULATION
Current
Nominal Overal Cable Carrying
Cross Diameter Short Circuit
Weight Nominal DC Insulation Capacity Current at
Section Area Sheath Cross Resistant at Resistance at at 30oC 1 Sec
Section Area 20oC 70oC
Approximity Approximity In Air
mm2
mm kg/km mm 2
Max. (Ω/km) Min. (MΩ.km) Max. A Max. (kA)
3 x 0.75 5.1 x 9.9 81.04 0.75 26.0 0.011 6 0.10
3x1 5.2 x 10.2 90.39 1 19.5 0.010 10 0.13
3 x 1.5 5.7 x 11.5 118.79 1.5 13.3 0.010 15 0.19
3 x 2.5 6.3 x 13.3 167.44 2.5 7.98 0.009 20 0.32
CONSTRUCTION PERFORMANCE
Copper Conductor
PVC Sheath
SNI 04-6629.5 60227 IEC 53 WILSON Cu/PVC/PVC-f 3 x 0.75 mm2 300/500 V ( ) LMK
Insulation
Features
• 99.99 % Pure Cooper Conductor
• Easy Installation
• Digital Printing Marking / m’
• Glossy Finishing Sheath
• Flexibility
No. of Length /
Component Nominal Nominal Coil
Wires/Dia of Thickness Outside Thickness Outside
Size Diameter Diameter
Component
Wires
mm mm mm mm mm m
2C 0.5 0.3 1.15 0.7 3.7 100 / 500
4C 0.6 0.3 1.25 0.7 3.9 100 / 500
2C 0.5 0.3 1.15 0.7 4.3 100 / 500
4C 0.6 0.3 1.25 0.7 4.5 100 / 500
CONSTRUCTION PERFORMANCE
Copper Conductor
WILSON 2Cx0.50Cu
Insulation
Features
• 99.99 % Pure Cooper Conductor
• Easy Installation
• Digital Printing Marking / m’
• Glossy Finishing Insulation
• Flexibility
mm mm mm mm mm mm mm m
RG - 59 1.0 1.35 3.4 12.5 x 0.08 16 x 4 / 0.12 0.9 6.0 100 / 500
18 AWG (2C) 30/0.18 0.45 2.0 - - 0.3 4.6
CONSTRUCTION PERFORMANCE
Copper Conductor
Insulation (PVC)
Outer Conductor
WILSON COAXIAL CABLE RG 6/FW - 75 OHM CCTV CABLE - UV RESISTANCE RoHS Compliance
Sheath (PVC)
Copper Conductor
Insulation (PEF)
Outer Conductor
Alumunium Foil
WILSON CCTV COAXIAL CABLE RG-59 + POWER CORD 18AWGx2C RoHS Compliance
Sheath (PVC)
Insulation (PE)
Copper Conductor
Features
• 99.99 % Pure Cooper Conductor
• Easy Installation
• Digital Printing Marking / m’
• Glossy Finishing Insulation
• Flexibility
CONDUCTOR INSULATION
mm2 N/mm mm mm m
2 x 0.3 2 x 0.6 Copper Wire 0.8 2.2
100 or 500
1 x 1.2 Steel Wire 0.8 2.8
CONSTRUCTION PERFORMANCE
Galvanized steel
Copper Conductor
Insulation (PE)
Features
• 99.99 % Pure Cooper Conductor
• Easy Installation
• Digital Printing Marking / m’
• Glossy Finishing Insulation
• Flexibility
High-quality PVC
Put out the fire 3 time faster
WILSON CABLES
CABLE MANUFACTURE
REFRENCE
REFERENCE
Building Cables
Overloaded circuits, electrical faults, and Table Cable Size With MCB
faulty wiring can all cause electrical fires. It is
Nominal Area Max Power MCB
a good idea to get an electrical inspection of (Sq.mm) (Watt) (Ampere)
your home, especially if it is an older home or
you never had an inspection. Signs of 0.75 880 4
electrical problems in a home include blown
fuses, tripped circuits, flickering lights and 1.5 1.320 6
warm, cracked, or sparking outlets.
2.5 2.000 10
choose the type of cable with Indonesian
national standard (SNI), SPLN and LMK. Have 4 3.520 16
the electrical installation in your home checked
by a registered electrician. Homeowners 6 4.400 20
should have this done every ten years, or when
you move house. Electrical Safety First 10 5.500 25
recommends that privately rented properties
are checked every five years, or on change of 16 7.700 35
tenancy.
25 13.200 60
35 22.000 100
50 27.500 125
70 35.000 160
95 55.000 200
WILSON CABLES
CABLE MANUFACTURE
REFERENCE
Audio Cables
18 AWG
(1.0mm) 2.4m max 4.8m max 7.3m max 9.7m max
16 AWG
(1.3mm) 3.6m max 7.3m max 11m max 14.8m max
WILSON CABLES
CABLE MANUFACTURE
REFRENCE
REFERENCE
Welding Cables
Welding cable is the electrical conductor for the
welding current. It consists of a series of fine copper
strands wrapped inside a non-conductive, durable
jacket (typically some type of synthetic or natural
rubber of various colors). The fine copper strands
give welding cable more flexibility than other types
of electrical conductors and the insulating jacket is
designed to hold up to repeated movement over
rough surfaces. As the current level increases
(measured in amperage or amps), the diameter of
the welding cable and resulting cross sectional area
of the copper stranding needs to increase. The
concept is similar to the flow of water through a Cable Size : Metric Cross-Sectional Area
hose. A larger diameter hose is needed in order to
Standart
carry a greater volume of water. You use a smaller Cable Size
(AWG)
Equlvalent Size
(mm2)
International Size
(mm2)
hose to water your garden, while the fire department
uses a much larger hose to fight fires. 6 13.3 10
Scale
Diameter of Maximum
Welding wire that connection of
can be used welding algae cable
Type (mm) (mm)
Current Arc
Rating Voltage
Use (%) (A) (V)
WILSON CABLES
CABLE MANUFACTURE
REFERENCE
Automotive Cables
Measure the diameter of the conductor (strand
package) only, not including the insulation layer.
ALSO NOTE: AWG sizing generally refers to a
single, solid, round conductor. The AWG of a
stranded wire is determined by the total
cross-sectional area of the conductor, which
determines the current-carrying capacity and
electrical resistance. Because small gaps may
exist between the strands, a stranded wire will
usually measure at a slightly larger overall
diameter than a solid wire of the same AWG
size).
Under
Conductor Insulator Rical Character Cutting Current Package
WILSON CABLES
CABLE MANUFACTURE
* WILSON CABLES
Nomor: 01 /WSU-SPDNll/2022
Perihal: SURAT PENUNJUKKAN DISTRIBUTOR RESMI
Sebagai salah satu Distributor / Penyalur Resmi untuk pemasaran produk kabel dan produk pendukung
kabel dari PT Willson Surya Unggul dengan merk "WILSON". Surat Penunjukkan ini berlaku untuk
pemasaran baik offline maupun online.
Demikian Surat Penunjukkan ini kami buat untuk dipergunakan sebagaimana mestinya.
T
wwwww.cold