Mechanically Operated
Piston Pumps for Oil
The pumps shown in this brochure can be mechanically operated by any moving part of a machine, but care must be taken to ensure that
the piston always fully extends. This is necessary because the suction ports are opened by the piston at the end of its stroke. On request,
these pumps can also be supplied for hydraulic operation.
Fitting instructions
After the pump has been temporarily positioned, loosen the set screw and place a 0.1 mm thick shim between the plunger and the
operating device (eccentric wheel, cam or the like). Then operate the pump until the upper dead center of the operating device is reached
and tighten the set screw. Care must be taken to lubricate the plunger.
Lubrication pump
w i t h residual pressure release valve
This pump is used for small central lubrication systems.
Keep main line to the distributors as short as possible and rising
from pump to distributors.
The number of lubrication points should not exceed eight.
A safety valve should be mounted downstream from the
set screw
distributors.
1
The system capacity ) should not exceed two-thirds of the output
per full stroke to ensure the required spare capacity for the
pressure build-up in the system.
Always fit pump with pressure port pointing upwards.
Fully extend pump stroke, i.e. both extremities must be reached.
1
) Total output of all distributors in system,
+ 25 % of this value,
+ allow 1 ccm per m if the main line is flexible (expansion loss). Fig. 1
P = pressure port
S = suction port (inlet)
B7
Mechanically operated piston pumps for oil
Feed pumps
set screw
w i t h o u t residual pressure release valves
With variable output and number of strokes, these pumps permit
universal application, e.g. filling of pressure reservoirs for general
purposes and oil reservoirs for lubrication systems.
They are not fitted with release valves and thus are not suitable
for direct connection to distributor systems.
Fig. 2
Please note:
All equipment may only be installed and/or assembled by qualified personnel.
Observe existing safety regulations.