Note : As per latest gazette of India , REGD. NO. D. L.-33004/99, Issued by MINISTRY OF COMMERCE
AND INDUSTRY, Para 3B. Exemption of boiler or boiler components, No need to perform the strength
calculation of boiler or any boiler component as per IBR , if calculation is done as per ASME for said boiler
or part of boiler components . Hence , IBR calculation is not required for steam coil as ASME calculation is
performed.
Link to gazette published by MINISTRY OF COMMERCE AND INDUSTRY of India.
http://dipp.nic.in/sites/default/files/boiler_rules_updated/Amendmnet_1_2015_13May2015.pdf
2

Input Echo, Component 1, Description: Heating coil

Internal pressure results, Shell Number 1, Desc.: Heating coil

Thickness Due to Internal Pressure (Tr):

Max. All. Working Pressure at Given Thickness (MAWP):

Maximum Allowable Pressure, New and Cold (MAPNC):

Actual stress at given pressure and thickness (Sact):

SUMMARY OF INTERNAL PRESSURE RESULTS:

Hydrostatic Test Pressures ( Measured at High Point ):


3

External Pressure Results, Shell Number 1, Desc.: Heating coil


ASME Code, Section VIII, Division 1, 2017

Results for Max. Allowable External Pressure (Emawp):

Results for Reqd Thickness for Ext. Pressure (Tca):

Results for Maximum Length Calculation: No Conversion

Summary of External Pressure Results:

Weight and Volume Results, No C.A. :