CamScanner 10-09-2022 17.11

You might also like

Download as pdf
Download as pdf
You are on page 1of 4
1. Safety precautic The following symbol mean: A Caution: Read these operating instructions fully before use and pay particular attention to sections containing this symbol + Use only as specified by the operating instructions, or the intrinsic protection may be impaired. + After transport or storage in humid conditions, dry out the unit before connecting it to the supply voltage. During drying out the intrinsic protection may be impaired + Connect only to a power supply with a voltage corresponding to that on the serial number label. + Do not use other power supply units than recommended by the manufacturer. + Ensure that the mains switch and isolating device (power supply connector) are easily accessible during use. + Do not operate the unit outside the laboratory premises. + Do not operate the unit in premises with aggressive or explosive chemical mixtures. « Before moving, disconnect at the power supply socket. + Do not start operation at maximum speed. + Do not use the tubes bigger than 28,5 mm in diameter. + Do not stop the vortex head or platform rotation with a hand during operation. + If liquid is spilt inside the unit, disconnect it from the power supply and have it checked by a competent person. + Before using any cleaning or decontamination method except those recommended by the manufacturer, user should check with the manufacturer that the proposed method will not damage the equipment. + The unit should be saved from shocks and falling. impulsado por CamScanner 2. General |. ormation ed for mixing substances in tubes using the din a variety of applications including general cell's suspensions vortexing, chemical Personal Vortex V-1 plus is design eccentric mechanism. Vortex can be use test tube mixing, tissue samples mixing, reagents mixing, etc. The vortex is equipped with 20 mm diameter single Polystyrol mixing cup for mixing one tube ata time. Vortex V-1 plus is intended for two operations: - continuous mixing; - intermittent mixing (activated by touching the mixing cup with a test tube). Vortex V-1 plus operates at variable speeds from 750 to 3000 RPM providing different mixing intensity (from gentle shaking to vigorous vortexing). impulsado por CamScanner 3.1. Unpacking Remove packing materials carefully and retain for future shipment or storage of the unit. 3.2. Complete set The unit set includes: ITEM QUANTITY INTHE SET | Personal vortex V-1 plus 1 pce. | External power supply unit 1 pce. | Operating Manual; Specifications; Certificate 1 copy \ 3.3. Setup — place the unit on the working area; - plug the external power supply unit into the 12 V socket at the rear side of the unit. impulsado por CamScanner 4.1, Connect the external power supply unit to the mains. 4.2. Continuous operation mode-CS 4.2.1. Tum the TS/CS switch (fig-1 /2) into position cs. 4.2.2. Adjust the necessary speed using the Speed knob (+ ) 4.2.3. Gently holding a tube with two fingers at its upper pari dip the tube’s lower part into the conic deepening of the vortex head (Polystyrol cup) (Fig.2/1). Control the intensity of mixing by varying pressure of a tube to the vortex head. 4.2.4.Atthe end of operation turn the TS/CS switch into positi 4.3. Touch operation mode-TS 4.4.1. Tum the TS/CS switch (fig.1/2) into position TS. 4.4.2.Gently holding a tube with two fingers at its upper part dip the tube's lower part into the conic deepening of the vortex head (Fig.1/1 ). Vortex will be activated when pressing the mixing cup witha testtube. 4.4.3. Adjust the necessary speed (desired mixing level) using the Speed knob (fig. 1/3). 4.4.4. Control the intensity by varying pressut to the Polystyrol cup (Fig.1/1). 4.4. Atthe and of operation disconnect the power supp! ion TS. re of a tube ly unit from the mains. Fig.1 Personal vortex V-1 plus impulsa pulsado por CamScanner

You might also like