G3AU Project
HELIUM LEAK TEST PROCEDURE
TEIPL Work No: 6341
Project Doc. No.: VD-M-U00-STA-PRC-BYDC001-5008 Page 1 of 07
P.O No: P/6341/12153/BYDA001
Vendor Work No: DV364/DV365 Vendor Doc. No.: 2016-DV364-HLT Date:28-JUL-2016
FOR APPORVAL
☐ AP APPROVED
☐ NR NOT BE RETURNED
PROJECT ORIGINATOR
RECEIVED DATE
SUBRATA JIGAR
2 28-Jul-2016 2nd Issue SUBRATA BERA JIGAR PRAJAPATI
BERA PRAJAPATI
SUBRATA JIGAR
1 19-Jul-2016 2nd Issue SUBRATA BERA JIGAR PRAJAPATI
BERA PRAJAPATI
SUBRATA JIGAR
0 1-Jun-2016 1st Issue SUBRATA BERA JIGAR PRAJAPATI
BERA PRAJAPATI
DATE
REV ISSUE PURPOSE PREPARE CHECKED APPROVED AUTHOLIZED
ISSUED
INSPECTION : AI/LRA/TOYO
REVISION DETAILS
Procedure No. : 2015‐DV364‐HLT
Revision : 02
HELIUM LEAK TEST PROCEDURE Date :28.07.2016
Job No. : DV‐364 & DV‐365
Page : 2 OF 4
1.0 SCOPE
This procedure is applicable for Helium leak testing for Lining patrs of item No. U-DC3101 / U-
DC4101.
7.0 CALIBRATION
8.0 PROCEDURE
8.1 The surface to be tested shall be free of oil, grease, paint and other contaminants which might
mask a leak. If liquids are used to clean the component or if a pressure test is performed before
leak testing, the component shall be dry before leak testing.
8.2 All vent holes for layered construction and holes for liners (Leak detection) or pipes for leak
detection shall be sealed using plugs or covers or sealing wax or cement or other suitable material
which can be readily and completely removed after completion of the test, except for the vent
holes/ leak detection path utilized for filling the gas and attaching the pressure gauge.
8.3 Calibration of Pressure gauge shall be checked before helium leak test.
8.4 The Helium gas shall be filled from the leak detection nozzle hole, which are remained at bottom
of the equipment, and Pressure gauge shall be connected to the leak detection nozzle hole which
are remained at top of the equipment.
8.5 Helium leak test shall be performed by hood technique. If any leakage found, then that seam will
be tested by sniffer method.
8.6 Prepare an envelope around the area/portion to be leak tested. All the openings/edges shall be
properly closed with suitable tape.
8.7 Fill up Helium gas within the space between Inner shell and Liner, and pressurize that to 0.2
kg/cm2(g). For Nozzle sleeve pressurize it to 1.0 kg/cm2 (g). The concentration of helium gas
shall be 100% by volume.
8.8 Allow soaking period for minimum 30 minutes.
8.9 Tune and warm up the Helium leak detector as per HLD manufacturer’s operating instruction.
8.10 Check and calibrate the instrument sensitivity with the standard leak for sensitivity required by
reference specification.
8.11 Insert the detector probe into envelope by puncturing plastic cover. Record the observation after
completing the response time of helium detector.
8.12 Pressurization shall be done in alternative compartments during testing.
11.0 DOCUMENTATION
11.1 Record the result in the format attached to this procedure.
Procedure No. : 2015‐DV364‐HLT
Revision : 02
HELIUM LEAK TEST PROCEDURE Date :28.07.2016
Job No. : DV‐364 & DV‐365
Page : 4 OF 4
Sketch for Helium Leak test
Gauge
Leak detection Pipe
Shell
Liner weld to be tested
Plastic Envelop
Leak detection Pipe
Helium Inlet
3 3
Shell 1
General Description
Manufactured By
Owner
Testing Agency
TPIA
P.O. No. & Date
Project
Test Object
Tag No.
Drawing No.
Material
Test Location
Test Operator
Reference Specification
Test Equipment and Accessories Detail
Make Model Sr. No.
Helium Leak Detector
Calibration Detail
Helium Leak Detector Calibration
Stage Time Target Leak Value Calibration Achieved M/c Background
Start of Test
End of Test
Signature
Name
Date
HELIUM LEAK TEST REPORT
Testing Parameters Detail
Test Medium
Test Temperature
Scope of Testing / Area of test
Extent of Testing
Stage of Testing
Surface Condition
Test Technique
Soaking Time
Pressurization Details
Nitrogen Pressure [kg/cm2 (g)]
Helium Pressure [kg/cm2 (g)]
Total Pressure [kg/cm2 (g)]
Helium Concentration
Test Observation
Observed Leak (Total) Back Ground Actual Leak Rate(QA)
Test Object
R1 R2 = (R1-R2)100/%TG
Signature
Name
Date