CMT-007A - Digital Counter

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

= COUNTER

2 CMT-007A
DIGITAL COUNTER
RELATIVE HUMIDITY & TEMPERATURE TRANSMITTER

TECHNICAL SPECIFICATION DESCRIPTION


Power Supply 100 to 220 VAC 50/60 Hz • Digital Counting Machine
Power Consumption 1.5VA • 7-Segment display size 0.56 in 6 digits, 1 row
7 Segment, 6 Digit, • Receive inputs from sensors such as Photo Switch,
Display Size 0.56 Inch, 1 Rows Proximity Switch, Encoder, Contact, NPN, PNP
Range Display Measurement Range -199999 • Available operating modes: 7 operating modes
and Setting to 999999 • EEPRON memory can be stored. In case if power
Input Frequency 0 to 50 kHz failure
Input Type Photoswitch, Proximity, Contact, • Can communicate with computer via RS-485
Encoder , NPN , PNP
Input 24VDC 50 mA port MODBUS RTU
DC Source • Easy to use program through screen
for Sensor 12VDC 120 mA
Decimal Point 0 to 0.00000 OPERATION
Setting
Input Reset Dry Contact Digital display for industrial production with
Output Relay Output 3 Relay Output 5A/250VAC 7 - Segment real-time visualization. Used to control
Protocol MODBUS RTU production to meet the goal of reducing fault. Missed
Baud Rate 1200, 4800, 9600,19200 bps or used to check the status of the machine, count the
Parity None number of stock can work. Both count up an count
Communication Stop Bits 1 down. Up to 7 Output Mode can be connected yo
Data Bits 8 Bits Network. Control or display up to 32 units via RS-485
Support interface with computer to PLC Relay Output can
Device Node 32 control the alarm
Temperature -10 ํC to 60 ํC
Ambient Operation
Humidity 85 % RH Non-Condensing
Temperature -20 ํC to 80 ํC
Ambient Storage
Humidity 85 % RH Non-Condensing
Protection Degree Front
Rating
Protection IP52
Case Protection IP30
Rating
Installation Panel Mounting
Material ABS-V0
Size 48 x 96 x 80
Weight 300 g.
COUNTER =

CMT-007A 3
AIR, FLOW TRANSMITTER DIGITAL COUNTER

OUTPUT MODE
OUTPUT MODE 1 MODE 1 UP MODE 1 DOWN
When count is counted up or counted down to set point 1. set to OUT 1 ON until reset. And when the Count up or Count down
to the Set Point 2 value set, it will cause OUT 2 ON until the Reset Button is pressed
Out2: Retentive output/ count continuation (ON relay always in condition) Out2: Retentive output/ count continuation (ON relay always in condition)
Out1: Retentive Output (ON relay in condition) Out1: Retentive Output (ON relay in condition)

*Count Reset Value (CRV) is the value loaded at the reset count. Normally set CRV to 0 when reset. Count <- CRV

OUTPUT MODE 2 MODE 2 UP MODE 2 DOWN


When count is counted up or counted down to set point 1. set to OUT 1 ON until Reset is pressed. When Count counts up or down
to the Set Point 2, Set 2 will cause OUT 2. ON by time of one shot duration 2
Out2: One-shot output / count resetting (Relay Trigger and Reset Count) Out2: One-shot output / count resetting (Relay Trigger and Reset Count)
Out1: Retentive Output (ON relay in condition) Out1: Retentive Output (ON relay in condition)

OUTPUT MODE 3 MODE 3 UP MODE 3 DOWN


When count is counted up or counted down to set point 1. It will set OUT 1 ON according to the time of One shot duration 1
And when the Count counts up or counts down to the Set Point 2 value set, it will cause OUT 2. ON until the reset button is pressed
Out1: One-shot output (Relay Trigger and Open) Out1: One-shot output (Relay Trigger and Open)
Out2: Retentive output/ Count continuation (ON relay in condition) Out2: Retentive output/ Count continuation (ON relay in condition)
= COUNTER

4 CMT-007A
DIGITAL COUNTER

OUTPUT MODE
OUTPUT MODE 4 MODE 4 UP MODE 4 DOWN
When count is counted up or counted down to Set Point 1. It will set OUT 1 ON according to the time of One shot duration 1
And when the Count counts up or down to the Set Point 2 value set, it will cause OUT 2. ON by one shot duration 2 time
Out2: One-shot output/ Count resetting (ON relay in condition) Out2: One-shot output/ Count resetting (ON relay in condition)
Out1: One-shot output (Relay Trigger and Open) Out1: One-shot output (Relay Trigger and Open)

WIRING DIAGRAM
WIRING DIAGRAM INPUT WIRING EXAMPLES (CONTINUE)

Encoder direction Setting menu


Encoder rotate direction positive / negative Input E.dlr

DIMENSION
CMT-007A
COUNTER =

CMT-007A 5
DIGITAL
AIR, FLOW COUNTER
TRANSMITTER

SERIAL COMMUNICATION

DIMENSION CUTTING INSTALLATION


CMT-007A CMT-007A

CUTTING

ORDERING CODE
Standard
CMT-007A- A - -

ALARM SUPPLY FOR SENSOR


A Alarm 1 (SP1) (Standard) 12 12 VDC
B Alarm 2 (SP2) 24 24 VDC (Standard)
C Alarm 3 (Total)
OPTION
M RS-485