No.

MXDP-0060

Constant Distance Stop From Any


Frequency (By Time Delay) Example
Model: 3G3MX2

QUICK START GUIDE


MX2 – Constant Distance Stop From Any Frequency
(By Time)

1. Introduction .................................................................................................................................................... 3

2. New Parameters Added ............................................................................................................................... 3


2.1 User Parameters ..................................................................................................................................... 3
2.2 Other Parameters ................................................................................................................................... 3
2.3 Added Multifunction Input/Output ..................................................................................................... 3
2.4 Additional Run/Stop Sequence and Frequency Reference ......................................................... 4

3. Start-Up Procedure ....................................................................................................................................... 4

Page 2 of 4
MX2 – Constant Distance Stop From Any Frequency
(By Time)

1. Introduction

With this software we want to achieve constant stopping distance independently of the running
frequency. So is not necessary to change the position of the sensor when speed is modified.
On this case the internal stop command will be delayed based in the area corresponding to the
slowdown from the maximum frequency. The stopping area will be the same at any frequency keeping
constant the slowdown slope.

Drive programming allows to achieve and adjust the delay on the stop command

2. New Parameters Added

2.1 User Parameters

Parameters Function
P107 Estimated time delay to slowdown

2.2 Other Parameters

This parameters are used for the calculation and F003 is changed according to the distance that
should be cover.

Parameter Name Typ. value Units


A004 Maximum Frequency Setting 50.0 Hz
Deceleration (1) time setting corresponding to
F003 10.00 s
maximum frequency

2.3 Added Multifunction Input/Output

A special run input is created to perform the constant stop distance

Input
Parameter Name Description
Multifunction
RUN with constant stopping Assign the input that we
C001 – C007 56
distance make the special RUN

Page 3 of 4
MX2 – Constant Distance Stop From Any Frequency
(By Time)

2.4 Additional Run/Stop Sequence and Frequency Reference

The new multifunction input 56 is created to give the run and stop command that allows to stop with
constant speed.

OPERATION DIAGRAMS

A004

F003 Slope

FM

F003 Slope

P107
3. Start-Up Procedure

For startup only is necessary to set one of the digital input to 56 and start the Drive program by
parameter or by a digital input

EzSQ always executing


Parameter Name Typ. value Description
The program is in constant
A017 Easy sequence function selection 2
running

EzSQ executed with a digital input


Parameter Name Typ. value Description
Execute the program
A017 Easy sequence function selection 1
manually
Assign the input that
C001-C007 Executing EzSQ program 82
execute the program

Page 4 of 4