Z22 Double-Suction Axially-Split

Single-Stage Centrifugal Pump


60 Hz
Applications
Sulzer split casing pump, series Z22, our workhorse for many
demanding operations. They are trusted for pulp and paper
production as head box pumps and dilution pumps. In water
and sewage works, district heating systems, power plants and
other critical applications.

Design
The Z22 series comprises of 25 sizes with different impeller de-
sign available. This flexibility ensures that energy consumption
is minimised throughout a pumps’ complete operating range.
Many of these pumps have a peak efficiency of over 90%.
Each pump is tested to ISO 9906, Grade 2, or other agreed
standard.

Pump casing
Pumps generating high heads are designed to reduce radial
forces, ensuring minimal shaft deflection and low bearing
loads.
The casing is axially split, which permits removal of the com-
plete rotor without moving either the piping or the motor.
Replaceable wear rings between the suction and discharge
side enable high efficiency throughout the whole lifetime of the Properties
pump.

Impeller Capacity 500-20000 m3/h (2200-89000 USgpm)


The closed impellers are designed for optimum flow conditions. Head 10-200 m (33-656 ft)
Each impeller is statically and dynamically balanced according
to ISO 1940, Grade 6.3 (For fan pump Grade 2.5). Temperature Max. 100-140°C (212°F-284°F)
Double suction low pulsation impellers are available de- depending on size and material
signed to meet stringent performance requirements for head
Pressure rating PN6 to PN25 owing to pump size
box pumps. These impellers gives practically zero hydraulic
axial forces and have low NPSH requirements which gives and material
reduced installation costs.
Flanges ISO 7005 PN10-PN25 or
For each pump size there are normally two or more impeller
variants available to best suit various applications. ANSI 125-300
Lubrication Grease as standard
Shaft and shaft sleeves
Sturdy shaft/bearing construction ensures smooth running with
very low vibrations.
The shaft deflection at the seal positions is less than 0.05
mm (0.002 inch). At its entire length the shaft is protected by Bearings
shaft sleeves, which are O-ring sealed. Grease lubricated bearings designed for a calculated bearing
life of at least 80 000 hours, which is equivalent to 10 years con-
Shaft seals tinuous service. Only maintenance of bearings and shaft seals
All sizes can be supplied with mechanical seals and most sizes are necessary.
with gland packing. Deflectors and V-ring seals protect the bearings against
moisture and dirt ingress both when running or at standstill.
The bearing brackets are drilled as standard for SPM nipples
and can also be fitted with temperature sensors.
The rigid axial thrust bearing can take high external axial
loads, and the pumps can therefore be vertically mounted.

Your benefits

* Optimal reliability. Sturdy design ensures smooth and trou-


ble-free operation.

* High efficiency. The design guarantee high effciencies and


large energy savings year in and year out.

* Low installation costs. Double suction impellers with lower


NPSH requirements give minimal installation costs.

* Maximum flexibility. Wide range with many installation op-


tions to meet specific applications needs.

* Simplicity of service. Easy dismantling thanks to the split


casing design.

Cardo.indd 1 12-05-30 11.15.30


Type designations Performance curves
1780 1185 890 710 rpm
Z22 800/700-80
Z22 Pump series 150 200 500 1000 2000 l/s 5000
800 Suction size code Ft
m 500 1000 2 3 4 5 10000 m3/h 20000
700 Discharge size 800 250
code 700
200 500 50
600 /30
-80 Impeller size code 400 0-75 0/40
/35 0-8 80
350 0-70 0 60 0/6
500 150 /300 0/4
00
-61 400 00 -12
/30 40 -90
0-60 0/3 0
400 0 0-
55
100 80
50 0/
300 0/4 60
90 00 0-1
-60 05
80
250 35 50
70 /20 0/ 0/
35 50

60
0-4

80
0 0- 0-

0/ 6

0/
200

90
60 45 70

60 00
50

70

0/8
0/4

0- /600

0-
75
00

80

00
-60

80
50

-90
0/7
150

50

90 0-80
700
35

0
0/

0/
-65
40 0/

40

80
/70
30

0-

0-
0- 50

55

0
0/

90
35

-6 5

100
250 40
/20 0-6
100

0/1
30 0-4 0
0

0
45

00-
0/4

700

90
35 00
-40

/70
0/
30

0
20 0-

-65
35

50 15
500 1000 2000 3000 4000 5000 10000 m3/h 20000

2000 5000 10000 20000 50000 USGPM 100000

Installation versions
All pumps can be installed
horizontally or vertically and
some can be supplied with
right-angle connections.
Flexible steel support de-
sign makes it easily to adopt
customers special require-
ments, mostly incline suction
discharge configuration.
For vertical installations
the motor can be mounted
on a tripod and driven via a
cardan shaft to the stool-
mounted pump. The pump
can also be mounted on a
stool and driven via a cardan
shaft.

Materials
Code 01 02 05 06 07 24 41
Pump casing Cast iron Cast iron Cast iron Nodular Nodular Stainless Bronze
0120 0120 0120 iron 0717 iron 0717 steel 2324 5444
Wear rings Cast iron Bronze Stainless Cast iron Bronze Stainless Bronze
0120 5204-15 steel 2324 0120 5204-15 steel 2324 5204-15
Impeller Cast iron Bronze Stainless Cast iron Bronze Stainless Bronze
0120 5444 steel 2324 0120 5444 steel 2324 5444
Shaft Steel Steel Stainless Steel Steel Stainless Stainless
1650/1672 1650/1672 steel 2324 1650/1672 1650/1672 steel 2324 steel 2324
Shaft sleeve Bronze Bronze Stainl. steel Bronze Bronze Stainl. steel Bronze
5204-15 5204-15 2377/2348 5204-15 5204-15 2377/2348 5204-15

www.sulzer.com
E10118 us 5.2012 © Sulzer Pumps

This data sheet is a general presentation. It does not provide any warranty or guarantee of any kind. Please, contact us for a description of the warranties and guarantees offered with