1 2 3 4 5 6 7 8 9 10 11 12
FABRICATION MATERIALS
N CONTINUED ON PT COMPONENT DESCRIPTION SIZE ITEM CODE QTY
AHWR-1020-2"-D-1012210-61440C1-01-PP NO (Inch)
AHW-10-PDFEED-MP-2343-00002-0095
E 188550 PIPE
A A
N 201525
1 PIPE Sch X GRE 3 74.79.39.005.9 8.2m
CL. EL +100225 F3 G4 B5
FITTINGS
3"NS
2 ELBOW 90 DEG LR SW Sch X GRE 3 76.C9.3H.90F.9 1
GR. EL .100000
FLANGES

223
3 SOCKET FLANGE GRE 600# GRE 3 76.W9.32.90F.9 1

ERECTION MATERIALS

1396
PT COMPONENT DESCRIPTION SIZE ITEM CODE QTY
NO (Inch)

www.pdo.co.om
B GASKETS B
4 GASKET flat ring (r/f face) 600# Nitrile Butadiene Rubber 3 85.45.81.205.9 1
(NBR for H2S<100 ppm) hardness 70+/-5 shore A

BOLTS

1
5 130 STUDBOLT WITH NUTS ASTM A193-B7M/A194-2HM 3/4 81.38.66.334.1 8

E 188550
N 201525 2
CL. EL +98826 89.70o
C CL. EL +98826 C

0
1 :20
OPE
SL

D D

2
704

E E

1
S
3"N

CONTINUED ON
AHWR-1020-4"-D-1012204-17011M6-01
AHW-10-PDFEED-MP-2343-00002-0129
E 181508
N 201525

F
CL. EL +98791

0.30o
A F

www.pdo.co.om
FEED OFFICE
bsi. ISO
9001:2015
Quality
Management
G G
FM546425
NOTES: MATERIAL PIPING CLASS LINE CONDITIONS PROJECT TITLE
1. ALL DIMENSIONS, ELEVATIONS & CO-ORDINATES ARE IN MM GRE 17011M6 DESIGN TEST
GREATER AL HUWAISAH AREA DEVELOPMENT PHASE-1
2. THIS ISOMETRIC SHALL BE READ IN CONJUNCTION WITH GENERAL NOTES.
INSULATION TYPE STRESS ANALYSIS AREA PLANT WBS No.
N/A BYGRE VEND PAINTING SYSTEM N/A PRESS kPa (g) 700/- By GRE Vend
3. THIS ISOMETRIC IS PRELIMINARY & TO BE USED ONLY FOR
INSULATION THICKNESS N/A INSPECTION CLASS N/A COLOUR N/A TEMP ( C)
o
100/0 RMS-2 REMOTE MANIFOLD STATION-2 C.AB.GHW.DF.01.ED2
DIMENSIONS/ROUTING PURPOSE. GRE VENDOR IS RESPONSIBLE FOR
HEAT TRACING N/A TEST TYPE HYDRO TEST MODEL AREA LINE No. PROJECT ID
CARRYING OUT FURTHER DETAILING WITH RESPECT TO GRE FITTING

DIMENSIONS. STRESS RELIEVE N/A RATING 150# AHWR-1020-CU 3"-D-1012206-17011M6-01 GOY0000Y0660


4. GRE VENDOR TO CONSIDER STEEL BACKING/SPACER/RETAINER RING, DRAWN CHECKED APPROVED STRESSED CLIENT APPROVED
WHEREVER FLAT FACE FLANGES ARE CONNECTED TO RAISED FACE BY DATE BY DATE BY DATE BY DATE BY DATE
H FLANGES. ALL BOLT LENGTHS TO BE CONFIRMED BY GRE VENDOR.
H
PEFS AHW-10-PDFEED-PX-2365-00008-0001 PMC 25.07.21 MH/RG 25.07.21 SSP 25.07.21

STRESS CALC NO - 01 29.07.21 APPROVED FOR CONSTRUCTION PMC MH/RG SSP DRAWING NO SHEET REV
STRESS CLIENT
GA AHW-10-PDFEED-MP-4033-00004-0009 REV DATE DESCRIPTION DRN. CHKD. APPD. APP. APP. AHW-10-PDFEED-MP-2343-00002-0127 1 OF 1 01
REFERENCE DRAWINGS & DOCUMENTS REVISION DETAILS
1 2 3 4 5 6 7 8 9 10 11 12
This drawing and all information theron is the property of PetroleumDevelopment Oman and shall be returned on demand. It is issued on the condition that except with our written permission it must not be reproduced, copied or communicated to any other party nor be used for any purpose other than that stated in the particular enquiry, order or contract with which it is issued.
DATE: 27-7-2021-18:16 PROJ: YRP 12.1.SP4.40 ZONE: AHWR-1020-CU-PI-01-D USER: PRITAM.CHAVAN
PIPE: AHWR-1020-3"-D-1012206-17011M6-01
Responsible Engineer : DO NOT SCALE Closed dateASK.
IF IN DOUBT : 09/12/2021