Trial 01
Trial 01
1
Company: Page: 1
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 12/09/2022
E-Mail:
Specifiers comments:
Seismic loads No
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.my Hilti PROFIS Rebar 2.6.1
Company: Page: 2
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 12/09/2022
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.my Hilti PROFIS Rebar 2.6.1
Company: Page: 3
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 12/09/2022
E-Mail:
Selected solution
Bar size Drill bit size Bar spacing Distance Required drill hole
centre/centre centre/surface
Layer of bars Ø [mm] D [mm] s [mm] cs [mm] linst [mm]
Top / left 1 10.0 12.0 100 55.0 245
Bottom / right 1 10.0 12.0 100 55.0 245
Required accessories
Section Analysis
Upper layer
Design Input
Lower layer
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.my Hilti PROFIS Rebar 2.6.1
Company: Page: 4
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 12/09/2022
E-Mail:
Design Input
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.my Hilti PROFIS Rebar 2.6.1
Company: Page: 5
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 12/09/2022
E-Mail:
Remarks
This design exclusively considers the local load transfer from the post-installed tensile reinforcement at the intersection between new and
existing concrete. The joint surfaces for concreting must be roughened to at least such an extent that aggregates protrude. It assumes that
adequate transverse reinforcement is provided in the anchorage area if required.
The shear load carrying capacity of the cross section has to be designed separately.
The Installation (drilling, cleaning, setting) must be according to the approval!
Fixed diameter and spacing selected. Please be aware that over-reinforcement of the section may lead to brittle failure of the fastening.
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be
followed to ensure a proper installation.
Minimum reinforcement requirements are not checked by the software.
It is user responsibility to provide sufficient shear reinforcement and resistance VRd,s in accordance to EN 1992-1-1:2004 par. 6.2.3
It is assumed that strength reduction factor v1 = v (EN 1992-1-1:2004 par.6.2.3(3) Note 1) and αcw = 1 (EN 1992-1-1:2004 par.6.2.3(3) Note 3)
The verification of the interface shear for connections that carry gravity loads directly through the joint requires engineering judgment.
Consideration should be given to the potential for relaxation of the anchorage and its potential effect on shear transfer across the interface.
This is especially true for cantilever elements.
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan