Model C275S Generator set

General Performance Data


Prime Power 250KVA/200KW Brand Cummins
Engine
Stand by Power 275KVA/220KW Model 6LTAA8.9-G2

Frequency/Speed 50Hz/1500rpm Control module Deepsea 4520

Rated Power Factor(cosφ) 0.8 Rated Current 361A

Standard Voltage 230V/400V Capacity of Breaker 400A

Phases 3 Starting Voltage DC24V

Fuel consumption Standards followed

Rated output Fuel consumption rate ISO9001 ISO14001

100%Standby 199/KW.h 58 L/h ISO8528 ISO12100

100%Prime 197/KW.h 53 L/h ISO13849 EN12601

75%Prime 197/KW.h 39 L/h GB12786 GB/T2820

50%Prime 201/KW.h 27 L/h IEC60034 IEC60204

25%Prime 220/KW.h 15 L/h CE RETIE

Dimensions and Weights

Type Open Silent

Length(mm) 2450 3600

Width(mm) 950 1200

Height(mm) 1800 2000

Weight(kg) 2000 2700


Engine specification

Basic parameter Air induction system

Manufacturer Cummins Maximum allowable intake air restriction

Model 6LTAA8.9-G2 ---with clean filter element 3.7kPa

No. of cylinder 6 ---with dirty filter element 6.2kPa

Type 4 cycle, Vertical In-Line Intake Air alarm temperature 82℃

Prime Power 220kW/295HP Exhaust system

Standby Power 240kW/322HP Max. allowable back pressure 10kPa

Turbo-Charged, Air to
Induction system Standard exhaust pipe diameter 75mm
Air Cooled

Governor Electronic speed

Bore x Stroke 114x145mm Cooling system

Displacement 8.9L Coolant capacity

Compression ratio 16.6:1 ---Engine only 11.1L

Oil Capacity(Total) 27.6L ---Total system 34L

Coolant Capacity(Engine only) 11.1L ---With heat exchanger 22.9L

Cranking Motor Voltage DC24V Standard thermostat(modulating) range 82-95℃

Fuel System Minimum cap temerature 103kPa

North Oil P7100 inline Max. allowable top tank temerature


Type Injection system 104/100 ℃
pump for stand by/prime power
Min. Allowable flow of fuel to
58L/h
fuel pump

Electric system
Lubrication system
Min. recommended battery capacity (24V)
Oil Pressure
---10℃(50°F) & above- 0°F CCA 750
---Idle speed 103kPa

---Rated speed 206-414kPa --- 0℃(32°F) to 10℃(50°F)- 0°F CCA 750

Max. allowable oil temperature 121℃ ---18℃(0°F) to 0℃(32°F)- 0°F CCA 750

Oil Pan capacity - Low/High N/A Max. allowable resistance of Starting circuit 0.002ohm

Total system capacity 27.6L Starter(heave,Anode) DC24V

Battery recharge system, negative ground 70ampere

STAMFORD Alternator UCDI274K specification


Phases 3 Coating Vacuum impregnation

Poles 4 Insulation class H

Power factor(cosφ) 0.8 Protection IP23


Winding connection Star
Excitation system Self-excited
Winding pitch 2/3
Bearing Single Bearing
Voltage regulator type AVR
Coupling Flexible disc
Control system Introduction

Deepsea 4520 Auto start & auto mains


Key Features:
failure control panel
Deepsea 4520 is an auto mains failure controller for single ● Auto start/stop, load transfer and alarming
generator, it can monitor and protect the generator of generator
working all the time. it has a LCD display which clearly ● Remote start on or off load
shows the status of the engine. this controller include ● With hierarchical loading function
seven inputs and six outputs. This controller can also be ● Multiple start/stop cycles can be preset
prog rammed using the front panel or by using DSE ● 3 phase generator and mains voltage monitoring.
configuration Suite PC software ● Generator/load power detection(kW, kVA, kVAr PF)
● Overload protection (kW)
①Emergency stop button ● Load current monitoring and protection
● Engine speed protection
⑤ ②Power switch
● Engine pre-heat
③Power indicator
● Engine start idle & stop idle
④Operation buttons
● Battery voltage monitoring
④ ③② ① ⑤LCD display ● Start under the low battery
● 8 configurable outputs
⑥ ⑦ ⑧
● 8 configurable input
●Integral PLC editor
● TIer 4 CAN engine support
● Data logging facility
● DSE2130,DSE2157,DSE2548 expansion module
can be connected
● Support 0-10V or 4-20mA oil pressure sensor
⑨ ⑩

⑥Voltage and frequency trimmer ⑨MCB


⑦Governor ⑩Relay
⑧Charger

Main features: Protection:

● Multi language display ● Two sets of protection parameters can be preset


● Mains failure self starting ● Normal alarm, electrical trip and shutdown alarm can be
● The running time of the engine can be recorded to set to effectively monitor the engine speed,oil pressure,
facilitate the maintenance and repair of the unit water temperature and oil level, as well as the frequency,
● User-friendly set-up and button layout voltage, current and power of the alternator, for
● LCD display can display multiple parameters at the complete engine/alternator protection
same time ● Low Oil Pressure
● Support EFI engine ● High water Temperature
● IP65 rating (with optional gasket) ● High voltage and low voltage
● PC and front panel configuration ● Overspeed
● 100 event records ● Emergency stop
● Data recording and trend analysis ● Fail to start
Soundproof Canopy Introduction:

Standard Type:
● The arc angle structure makes the appearance beautiful and ● The sufficient air in & out design ensure long-term and
not easy to bump stable operation of the unit

● High quality coating powder, chemical surface treatment &


● Isolation net is designed for air inlet, exhaust outlet and
100-120um coating thickness greatly improving the anti-
muffler outlet to prevent objects from entering the unit
corrosion and anti rust level

● Stainless steel hinge & door lock are beautiful and anti-rust ● High density foam used inside effectively reduces noise

● 2.0mm cold rolled plate used makes the body more solid ● Ceiling Lighting is equipped for easy operation

● The bottom forklift and loading port design enables easy ● The built-in base fuel tank with fuel filler set on the shell
loading and unloading facilitates refueling

● The drainage outlets are all connected to the outside for easy ● Models above medium power range are designed with top
operation hoisting mechanism to facilitate transportation of the unit.

Imitated container type:


● The shell base is independent from the unit with 3mm thick
● The shell is made of 3.0mm hot rolled steel plate so as to
checkered steel plate floor, which is beautiful & antiskid, and
withstand the lifting capacity of 15-ton without deformation
is convenient for overhaul & maintenance of the unit

● The switch cabinet and control panel are respectively set ● The door handle, lock and hinge are all made of stainless
on both sides of the shell for easy maintenance & operation steel to avoid rusting

● The shell looks similar to standard container, and can be ● The air out louver made of the mesh plate with podwer
loaded into 40HQ container for transportation, which is coating and pasted with high-density glass fiber is beautiful
convenient for shipping and not easy to rust, and can further reduce the noise

● The lifting eye holes are designed on the top same as the ● Isolation net is designed for air inlet, exhaust outlet and
standard container for easy handling muffler outlet to prevent objects from entering the unit

● The sufficient air in & out design ensure long-term and


● High density foam used inside effectively reduces noise
stable operation of the unit

● The built-in base fuel tank with fuel filler set on the shell ● The drainage outlets are all connected to the outside for easy
facilitates refueling operation

● Double emergency stop button set on different surfaces


● Ceiling Lighting is equipped for easy operation
enables quick response to operation requirements

Standard container type:


● The switch cabinet and control panel are respectively set
● Can be shipped on board directly during transportation
on both sides of the shell for easy maintenance & operation

● The mesh plate with podwer coating and inner pasted with ● The air in & out louver made of the mesh plate with podwer
high-density glass fiber is installed inside the shell, which is coating and pasted with high-density glass fiber is beautiful
beautiful and anti-rust, and can further reduce the noise and not easy to rust, and can further reduce the noise

● 3mm thick checkered steel plate floor is beautiful & antiskid, ● Isolation net is designed for air inlet, exhaust outlet and
and is convenient for overhaul & maintenance of the unit muffler outlet to prevent objects from entering the unit

● Double emergency stop button set on different surfaces ● The sufficient air in & out design ensure long-term and
enables quick response to operation requirements stable operation of the unit

● The independent daily fuel tank can be designed to put ● The drainage outlets are all connected to the outside for easy
inside to meet requirements of continuous operation operation

● The fuel filler is set on the shell to facilitate refueling ● Ceiling Lighting is equipped for easy operation
Decomposition diagram introduction of Typical Canopy

Standard supply scope:

① Engine
⑧ ② AC Alternator
③ Cooling Radiator
④ Auto Start Control Panel
⑨ ⑤ Main Ciruit Breaker
⑥ Built in Shock Pad
⑦ High Strength Frame
⑩ ⑧ Exhaust silencer
⑨ Bellow
⑩ Starting battery

Optional supply scope:


Genset Engine Alternator Control system

● Tool box ● Fuel heater ● Temp. detector for ● ATS


● Base fuel tank ● Fuel and water winding and bearing ● Synchronization
● External daily fuel tank separator ● PMG System
● Trailer ● Antirust, mildew and ● Adjustable earth relay
salt fog treatment
● Anti condensation
heater

Breaker Fuel system Lub-oil system Cooling system

● ABB ● Low fuel level alarm ● Lub oil heater ● Elec.coolant Heater
● Schneider ● Auto Fuel Pump ● Temp.-sensor
● T Vlave ● Oil drain Pump