PVsyst TRIAL
PVsyst - Simulation report
Stand alone system

Project: RUMIPAMBA
Variant: Nueva variante de simulación
Stand alone system with batteries
System power: 240 Wp

PVsyst TRIAL Rumipamba - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: RUMIPAMBA
Variant: Nueva variante de simulación

PVsyst V7.2.17
VC0, Simulation date:
07/08/22 11:05

PVsyst TRIAL
with v7.2.17

Project summary
Geographical Site Situation Project settings
Rumipamba Latitude -0.75 °S Albedo 0.20
Ecuador Longitude -78.56 °W
Altitude 3095 m
Time zone UTC-5

Meteo data
Rumipamba
Meteonorm 8.0 (2010-2014), Sat=100% - Sintético

System summary

PVsyst TRIAL
Stand alone system Stand alone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 10 / 0 ° Constant over the year
Average 1.5 kWh/Day

System information
PV Array Battery pack
Nb. of modules 8 units Technology Lithium-ion, LFP
Pnom total 240 Wp Nb. of units 1 unit
Voltage 26 V
Capacity 478 Ah

Results summary

PVsyst TRIAL
Available Energy
Used Energy
422.3 kWh/year
407.0 kWh/year

Project and results summary


Specific production 1759 kWh/kWp/year Perf. Ratio PR

Table of contents

General parameters, PV Array Characteristics, System losses


Solar Fraction SF
85.99 %
74.89 %

2
3
Detailed User's needs 4
Main results 5
Loss diagram 6
Special graphs 7

PVsyst TRIAL

PVsyst TRIAL
07/08/22 PVsyst Evaluation mode Page 2/7
Project: RUMIPAMBA
Variant: Nueva variante de simulación

PVsyst V7.2.17
VC0, Simulation date:
07/08/22 11:05

PVsyst TRIAL
with v7.2.17

General parameters
Stand alone system Stand alone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 10 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 1.5 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 30 Wp
PV Array Characteristics

Generic
Poly 30 Wp 36 cells
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
Adjustable Li-Ion
Lithium-ion, LFP
1 Unit
Number of PV modules 8 units Discharging min. SOC 10.0 %
Nominal (STC) 240 Wp Stored energy 10.6 kWh
Modules 4 Strings x 2 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 26 V
Pmpp 235 Wp Nominal Capacity 478 Ah (C10)
U mpp 28 V Temperature External ambient temperature
I mpp 8.4 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35

Total PV power
Nominal (STC) 0.240 kWp
Total 8 modules
Module area 1.9 m²
Cell area 1.2 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

-0.8 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
55 mΩ
1.5 % at STC

0.6 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
2.3 % at STC

0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
07/08/22 PVsyst Evaluation mode Page 3/7
Project: RUMIPAMBA
Variant: Nueva variante de simulación

PVsyst V7.2.17
VC0, Simulation date:
07/08/22 11:05

PVsyst TRIAL
with v7.2.17

Detailed User's needs


Daily household consumers, Constant over the year, average = 1.5 kWh/day
Annual values Hourly distribution

Number Power Use Energy


W Hour/day Wh/day
CAMARA IP 1 30W/lamp 24.0 720
ALARMA COMUNITARIA 1 25W/app 1.0 25
EQUIPOS VARIOS 1 30W/app 24.0 720
Consumidores en espera 24.0 24
Total daily energy 1489Wh/day

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
07/08/22 PVsyst Evaluation mode Page 4/7
Project: RUMIPAMBA
Variant: Nueva variante de simulación

PVsyst V7.2.17
VC0, Simulation date:
07/08/22 11:05

PVsyst TRIAL
with v7.2.17

Main results
System Production
Available Energy 422.3 kWh/year Specific production 1759 kWh/kWp/year
Used Energy 407.0 kWh/year Performance Ratio PR 85.99 %
Excess (unused) 0.0 kWh/year Solar Fraction SF 74.89 %
Loss of Load Battery aging (State of Wear)
Time Fraction 25.1 % Cycles SOW 98.7 %
Missing Energy 136.5 kWh/year Static SOW 80.0 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
181.5
137.6
165.0
159.7
GlobEff
kWh/m²
161.2
126.6
157.1
158.5
E_Avail
kWh
36.17
28.27
34.98
35.10
EUnused
kWh
0.000
0.000
0.000
0.000
E_Miss
kWh
9.02
13.93
10.28
12.40
E_User
kWh
37.14
27.76
35.88
32.27
E_Load
kWh
46.16
41.69
46.16
44.67
SolFrac
ratio
0.805
0.666
0.777
0.722
May 176.0 181.3 39.37 0.000 10.14 36.02 46.16 0.780
June 167.0 174.5 39.08 0.000 4.13 40.54 44.67 0.908
July 173.7 180.8 39.84 0.000 8.96 37.20 46.16 0.806
August 198.5 201.4 43.96 0.000 5.85 40.31 46.16 0.873
September 170.5 165.8 35.91 0.000 9.05 35.62 44.67 0.797
October 139.0 129.7 29.24 0.000 19.31 26.84 46.16 0.582
November 140.3 126.7 28.24 0.000 15.85 28.82 44.67 0.645

PVsyst TRIAL
December 161.4 142.5 32.10 0.000 17.53 28.63 46.16 0.620
Year 1970.3 1906.2 422.27 0.000 136.46 407.03 543.48 0.749

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
07/08/22 PVsyst Evaluation mode Page 5/7
Project: RUMIPAMBA
Variant: Nueva variante de simulación

PVsyst V7.2.17
VC0, Simulation date:
07/08/22 11:05

PVsyst TRIAL
with v7.2.17

Loss diagram
1970 kWh/m² Global horizontal irradiation
+0.1% Global incident in coll. plane

-3.36% IAM factor on global

1906 kWh/m² * 2 m² coll. Effective irradiation on collectors

efficiency at STC = 13.94% PV conversion

497.4 kWh Array nominal energy (at STC effic.)


-0.05% PV loss due to irradiance level

PVsyst TRIAL -7.06%

+0.75%

-0.70%

-3.47%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

0.00% Unused energy (battery full)


441.4 kWh Effective energy at the output of the array

-3.55% Converter Loss during operation (efficiency)

-1.89% Converter Loss over nominal conv. power

PVsyst TRIAL
-0.03% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
Missing energy 0.00% Converter Loss due to voltage threshold
25.11% 422.3 kWh Converter losses (effic, overload)
Direct use Stored Battery Storage
37.8% 62.2%
-0.01% Battery Stored Energy balance
-1.91% Battery efficiency loss

-2.43% Charge/Disch. Current Efficiency Loss

-1.75% Battery Self-discharge Current


136 kWh 407.0 kWh Energy supplied to the user

543.5 kWh Energy need of the user (Load)

PVsyst TRIAL

PVsyst TRIAL
07/08/22 PVsyst Evaluation mode Page 6/7
Project: RUMIPAMBA
Variant: Nueva variante de simulación

PVsyst V7.2.17
VC0, Simulation date:
07/08/22 11:05

PVsyst TRIAL
with v7.2.17

Special graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
07/08/22 PVsyst Evaluation mode Page 7/7

You might also like