For maximum protection, you should look for all three of the elements above. In other words, companies approved to design, install and commission LPCB approved products and systems.
January 2009
SECTION 1: PART
WHY USE AN LPS 1014 APPROVED COMPANY? Even with the best equipment, fire detection and alarm systems are only effective if correctly designed, installed, commissioned and maintained. It is therefore important that specifiers select only competent firms with a proven track record to undertake the work. LPS 1014 Requirements for Certificated Fire Detection and Alarm System Firms meets these requirements in full. LPS 1014 requires one encompassing Certificate of Conformity for the project, i.e. single point responsibility, which benefits all parties concerned, i.e. the insurer, the fire brigade, the building owner, etc. It is based on BS 5839-1 and also requires, where available, the use of third party approved products. For each system specifiers should request the issue of an LPCB Certificate of Conformity as part of the contract which: certifies that the fire detection and fire alarm system was designed, installed and commissioned in accordance with the installation rules applied, and ensures that the system is recorded by LPCB as a certificated fire detection and fire alarm installation.
The availability of more varied and sophisticated fire detection and alarm equipment means that it is even more important that firms listed to LPS 1014 are regularly assessed by LPCB for their competence to design, install, commission and service fire detection and fire alarm systems in accordance with acceptable installation rules or codes of practice. Where a firm has more than one office, each office is also required to meet the appropriate requirements of LPS 1014 to be eligible for certification, and is listed separately.
January 2009
PART 3: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
January 2009
SECTION 1: PART
Clymac Limited
Cloudway Court, Belton Road, Loughborough LE11 1LB UK Tel: +44 (0)1509 232651 Fax: +44 (0)1509 232665 E-mail: sales@clymac.co.uk Website: www.clymac.co.uk
Certificate No. CFA-154 to LPS 1014
January 2009
PART 3: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
January 2009
SECTION 1: PART
January 2009
PART 3: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
Kingfell Plc
Capitol Tower, 12th Floor, 91 Waterloo Road, London SE1 8RT UK Tel: +44 (0)845 60 61 999 Fax: +44 (0)845 25 81 999 E-mail: enquiries@kingfell.com Website: www.kingfell.com
Certificate No. CFA-138 to LPS 1014
January 2009
SECTION 1: PART
Niscayah Limited
Roding House, 970 Romford Road, London E12 5LP UK Tel: +44 (0)20 8553 5932 Fax: +44 (0)20 8478 8052 E-mail: info@niscayah.co.uk Website: www.niscayah.co.uk
Certificate No. CFA 169 to LPS 1014
January 2009
PART 3: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
10
January 2009
SECTION 1: PART
Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)
1A Unity Street, Old Market, Bristol BS2 0HX UK Tel: +44 (0)117 927 7271 Fax: +44 (0)117 929 7586 Website: www.wormald.co.uk
Certificate No. CFA-170 to LPS 1014
Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)
Hillcrest Business Park, Cinderbank, Dudley, West Midlands DY2 9AP UK Tel: +44 (0)1384 458993 Fax: +44 (0)1384 458981 E-mail: howfire@howfire.co.uk Website: www.howfire.co.uk
Certificate No. CFA-103 to LPS 1014
January 2009
11
PART 3: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)
206 Bedford Avenue, Slough Trading Estate, Slough SL1 4RY Tel: +44 (0)1753 574111 Fax: +44 (0)1753 824226 Website: www.wormald.co.uk
Certificate No. CFA-157 to LPS 1014
12
January 2009
SECTION 2: PART
A fire detection and fire alarm system is typically made up of a number of inter-linked components including detectors, manual call points, and alarm sounders connected to a control and indicating equipment by means of one or more transmission paths. All system components, including the control and indicating equipment are also connected to a power supply directly or indirectly. A fire detection and alarm system may be linked to other systems such as fire protection, or building management systems. These other systems are not considered as part of the fire detection and alarm systems. The fire detection and alarm systems may be networked together. Each of the components that constitute the fire detection and alarm system may be individually tested and approved against their appropriate standard to demonstrate their own performance and reliability but in order to ensure their compatibility and performance together within the system, certain systems tests and requirements must be fulfilled. The system standard specifies the requirements for compatibility and connectability assessment of system components that either comply with the requirements of EN 54 and/or with a manufacturers specification. The standard also includes requirements for the integrity of the fire detection and fire alarm system when connected to other systems. This section lists approved fire detection and alarm systems suitable for use in buildings for the protection of people and property. The system requirements ensure the compatibility of the different components of the system work reliably together. Each component of the fire detection and alarm systems listed in this section are approved to the applicable product standard and are listed in Part 3 sections 3, 4.1, 5, 6, and 7. The approval process for the system is outlined in scheme document SD040. Products listed in this section have been approved to LPS 1054:2001 Requirements for the evaluation of component compatibility for fire alarm systems This standard was designed for the UK market and applies to systems incorporating control and indicating equipment and power supply equipment complying with EN 54-2 Fire detection and fire alarm systems Control and indicating equipment and EN 54-4 Fire detection and fire alarm systems - Power supply equipment respectively. Networked systems are evaluated by ensuring that each control panel connected to the network can operate as a stand alone unit, in the event of failure of the network connections, and that failure of a control panel will not affect other control panels on the network. LPCB is now accepting products for approval to EN 54-13:2005 Compatibility assessment for system components which is applicable to the EU market. Note: Since LPCB uses national and international standards for the listing of products, in some instances, the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.
January 2009
13
PART 3: SECTION 2
FIRE DETECTION AND ALARM SYSTEMS
Certificated Products Precept fire alarm system Comprising the following products: Control Equipment Limited Precept 2, 4, 8, 16 and 32 zone control and indicating equipment. Apollo Fire Detectors Limited 55000-100 grade 1 rate of rise heat detector (45681-200 base) 55000-200 ionization smoke detector (45681-200 base) 55000-300 photoelectic smoke detector (45681-200 base) 53531-221 grade 1 rate of rise heat detector (45681-007 base) continued 53541-151 ionization smoke detector (45681-007 base) 53541-200 photoelectric smoke detector (45681-007 base) 55000-101 grade 2 rate of rise heat detector (45681-200 base) 55000-102 grade 3 rate of rise heat detector (45681-200 base) 55000-103 range 1 rate of rise heat detector (45681-200 base) 55000-104 range 2 rate of rise heat detector (45681-200 base) 55000-210 integrating ionization smoke detector (45681-200 base) Hochiki Corporation DFE-60 grade 2 fixed temperature heat detector (YBF-RL/4H5 base) DFE-90 range 1 fixed temperature heat detector (YBF-RL/4H5 base) DCC-1EL grade 1 rate of rise heat detector (YBF-RL/4H5 base) DCC-2EL grade 2 rate of rise heat detector (YBF-RL/4H5 base) DCC-R1EL range 1 rate of rise heat detector (YBF-RL/4H5 base) Hochiki Europe SLK-E photoelectric smoke detector (YBF-RL/4H5 base) SIH-E ionization smoke detector (YBF-RL/4H5 base) KAC Alarm Company Limited KR72 manual call point. Photain Controls Limited ISD-P91 ionization smoke detector PRR-P91 grade 1 rate of rise heat detector PHD-P90 range 1 fixed temperature heat detector Signature Industries - Clifford and Snell Alarms. MCP/R/F manual call point MCP/R/S manual call point System Sensor, St. Charles, Illinois, USA. 1151E ionization smoke detector (B401 base) 2151E photoelectric smoke detector (B401 base) Comprising the following products: Control Equipment Limited Discovery analogue addressable control and indicating equipment Apollo Fire Detectors Limited 55000-400 grade 2 analogue temperature monitor 55000-420 grade 2 analogue temperature monitor 58000-400 Discovery temperature monitor 55000-600 analogue photoelectric smoke monitor 55000-620 analogue photoelectric smoke monitor 58000-600 Discovery optical smoke monitor 55000-500 analogue ionisation smoke monitor 55000-520 analogue ionisation smoke monitor 58000-500 Discovery ionisation smoke monitor 58000-700 Discovery multisensor monitor 55000-900 surface and flush mounted manual call point 55000-910 flush mounted manual call point 55000-950 waterproof addressable manual call point 58000-900 flush and surface mounted manual call point 58000-910 flush mounted manual call point 58000-920 surface mounted manual call point 55000-700 XP95 short circuit isolator 45681-321 XP95 negative isolating base 45681-210 XP95 addressable mounting base LPCB Ref. No. 018b/S1
018d/01
14
January 2009
SECTION 2: PART
Certificate No: 092f to LPS 1054 Certificated Products ZP5 Mark 5 analogue addressable fire alarm system Comprising the following products: ZP5 Mark 5 control and indicating equipment 092e/01 ZP710-2 analogue ionisation smoke detector (ZP7-SB1 base) 092n/01 ZP730-2 analogue optical smoke sensor (ZP7-SB1 base) 092n/02 ZP720-3 grade 1 analogue heat sensor (ZP7-SB1 base) 092p/01 ZP785-2 addressable flush and surface mounted call point 092d/01 Comprising of the following products: ZP3 analogue addressable control and indicating equipment 092h/01 ZP710-2 analogue addressable ionisation smoke detector 092n/01 ZP730-2 analogue addressable optical smoke detector 092n/02 ZP720-3 analogue addressable grade 1 heat detector 092p/01 ZP785-2 addressable flush and surface mounted manual call point 092d/01 ZP760-2 short circuit isolator 092j/01 LPCB Ref. No. 092f/S1
092f/S2
Notifier By Honeywell
Charles Avenue, Burgess Hill, West Sussex RH15 9UF UK Tel: +44 (0)1444 230300 Fax: +44 (0)1444 230888 E-mail: sales@notifiersystems.co.uk Website: www.notifierfiresystems.co.uk
Certificate No: 154e to LPS 1054: Issue 2.1 Certificated Products Notifier NFS2-8 Fire Alarm System Comprising the following products: Notifier Fire Systems Ltd 124-345-002 NFS2-8, 2 Zone Conventional Control and Indicating Equipment 124-345-004 NFS2-8, 4 Zone Conventional Control and Indicating Equipment 124-345-008 NFS2-8, 8 Zone Conventional Control and Indicating Equipment Morley-IAS Fire Systems ECO 1002 Photoelectric smoke and heat detector ECO 1003 Photoelectric smoke detector ECO 1004T High Temperature 78C heat detector class BS ECO 1005 Heat detector class A1R ECO 1005T Fixed temperature heat detector class A2S KAC Alarm Company Ltd MCP1A-Rxxxxx Indoor/outdoor surface/flush mounting conventional manual call point NS4/R Sounder 4 tone wall mounting conventional (red) NS4/W Sounder 4 tone wall mounting conventional (white) NS14/R Sounder 14 tones wall mounting conventional (red) NS14/W Sounder 14 tones wall mounting conventional (white) LPCB Ref. No. 154e/S1
January 2009
15
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT Control and Indicating Equipment (CIE) is a component of a fire detection and alarm system through which other components may be connected to it such as detectors, manual call points, sounders, routing equipment, voice alarm equipment and fire protection equipment. It is supplied with power from power supply equipment which may be housed within the CIE enclosure or a separate enclosure. CIE is used to receive and send out signals that are related to fire. CIE also monitors the system for faults (short and open circuit or power supply faults) and indicate the status of the fire detection and alarm system. CIE designed to meet a European standard such as EN 54-2 or international standard such as ISO 7240-2 has certain options with requirements. For example, it may be designed to provide a signal to fire protection equipment or have dependencies on more than one alarm signal. Some CIEs have other functions which are not specified in the standard. These additional features are normally assessed such that they do not jeopardise compliance. The choice of CIE is dependant on the specific applications as recommended in the application guidelines for a specific job or building. Some CIEs have associated repeaters or mimic panels. These are normally used to repeat the indications given on the main CIE and sometimes they have control functions such as silencing sounders. There are no published standards that these repeaters or mimics can be tested against. This section lists Control and Indicating Equipment, and power supply equipment approved for use in fire detection and fire alarm systems in buildings. Repeaters or mimics that are listed in this section are only approved with their associated CIE and are subjected to the same environmental tests as the CIE. The initial approval and continued approval processes of these type of equipment are outlined in scheme document SD040. Products listed in this section have been approved to: EN 54-2:1997 Control and Indicating Equipment; EN 54-2:1997 + A1: 2006 and A2: 2007 Control and Indicating Equipment; EN 54-4:1997 Power supply equipment; EN 54-4:1997 + A1: 2002 and A2: 2006 Power supply equipment; ISO 7240-2:2003 Control and Indicating Equipment; ISO 7240-4:2003 Power supply equipment;
Audit: Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Notes: 1. EN 54-2:1997 is a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market from 1 August 2009. It is therefore recommended that control and Indicating Equipment are certificated to EN 54-2:1997 + A1:2002 and A2:2007. 2. EN 54-4:1997 is a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market from 1 August 2009. It is therefore recommended that power supply equipment are certificated to EN 54-4:1997 + A1:2002 and A2:2006. 3. Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly. 4. Where the Control and Indicating Equipment is of modular construction, and the use of certain modules (or printed circuit boards PCBs) is optional, these are listed with the applicable equipment.
16
January 2009
SECTION 3: PART
Mx-1004
018c/03
Mx-1008
018c/04
Mx-1016
018c/05
Mx-1032
018c/06
January 2009
17
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board 16 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board 32 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1629 Display board C1631 Repeater interface board LPCB Ref. No. 018c/R01
Mx-1108
Mx-1116
018c/R02
Mx-1132
018c/R03
Bardic by Honeywell
140 Waterside Road, Hamilton Industrial Estate, Leicester LE5 1TN UK Tel: +44 (0) 116 246 2212 Fax: +44 (0) 116 246 2210 Website: www.bardic.co.uk
Certificate No: 154d to EN 54-2: 1997 and EN 54-4: 1997 Certificated Products Bardic Zircon 2 Zone conventional controls and indicating equipment Including the following versions: 002-509-229 Language region 2, black & grey 4 Zone conventional controls and indicating equipment Including the following versions: 002-509-249 Language region 2, black & grey 8 Zone conventional controls and indicating equipment Including the following versions: 002-509-289 Language region 2, black & grey Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 10 Test condition LPCB Ref. No. 154d/09
Bardic Zircon
154d/10
Bardic Zircon
154d/11
CEAG
Postfach 11 16, D-59491 Soest, Germany Tel: +44 (0)1302 303397 Fax: +44 (0)1302 303220 Website: www.ceag.de
Certificate No: 714a to EN 54-2 :1997 and EN 54-4 :1997 Certificated Products CF 3000 Analogue addressable 2 and 4 Loop control and indicating equipment Incorporating the following units: ADF6 Back Assembled back box YPCB2153 Motherboard PCB LPCB Ref. No. 714a/01
18
January 2009
SECTION 3: PART
Certificated Products YPCB2147 PSU PCB YPCB2148 2 Loop Card (2 off) ADF6Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6 DISPCOVER Display PCB Cover ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover ADF6PRINTER Printer YPCB2187 Fire Brigade Interface Certified with the following options with requirements from EN54-2:1997: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition LPCB Ref. No.
Chubb Securit
10 Avenue du Centaure, B.P.38408-95806, Cergy-Pontoise Cedex, France Tel: +33 1 30173737 Fax: +33 1 30173707 Website: www.chubbsecurite.com
Certificate No: 747a to EN 54-2: 1997 and EN 54-4: 1997 Certificated Products Control Master 1000M-M Control Master 1000M-S 4 loop analogue addressable control indicating equipment (Medium enclosure) 4 loop analogue addressable control indicating equipment (Small enclosure) Incorporating the following units: CE00504 Main CPU CE00505 Main board display CE00506 Connection board CE00490 100W PSU and as optional modular units: CE00508 16 Zone LED module CE00507 32 Zone LED module CE00513 4 alarm zone control and indicating module CE00447 2 Way network interface CE00446 4 Way network interface CE00435A Lon high integrity isolator CE00514 16 fire protection zone control and indicating module CE00503 2 Loop System sensor interface CE00520 2 Loop Apollo interface Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 2 loop analogue addressable control indicating equipment (Medium enclosure) 2 loop analogue addressable control indicating equipment (Small enclosure) Incorporating the following units: CE00504 Main CPU CE00505 Main board display CE00506 Connection board CE00490 100W PSU and as optional modular units: LPCB Ref. No. 747a/01 747a/01
747a/02 747a/02
January 2009
19
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products CE00508 16 Zone LED module CE00507 32 Zone LED module CE00447 2 Way network interface CE00446 4 Way network interface CE00435A Lon high integrity isolator CE00513 4 alarm zone control and indicating module CE00514 16 fire protection zone control and indicating module Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 1 loop, analogue addressable control indicating equipment Incorporating the following units: CE00510 Main CPU CE00505 Main board display CE00506 Connection board CE00490 100W PSU and as optional modular units: CE00508 16 Zone LED module CE00436A 4 Way sounder board CE00437A 8 Way sounder board CE00507 32 Zone LED module CE00435A Lon high integrity isolator CE00513 4 alarm zone control and indicating module CE00514 16 fire protection zone control and indicating module Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition Remote unit Incorporating the following units: CE00509 Display board CE00484B Main board CE00489 40 W PSU and as optional modular units: CE00508 16 Zone LED module CE00507 32 Zone LED module CE00447 2 way network interface CE00446 4 way network interface CE00435A Lon high integrity isolator CE00513 4 alarm zone control and indicating module CE00514 16 Fire protection zone control and indicating module Remote unit Incorporating the following units: CE00509 Display board CE00484B Main board CE00490 100 W PSU and as optional modular units: CE00508 16 Zone LED module CE00507 32 Zone LED module CE00513 4 alarm zone control and indicating module CE00447 2 Way network interface CE00446 4 Way network interface CE00435A Lon high integrity isolator CE00514 16 fire protection zone control and indicating module The following repeaters and the remote units are approved for use with the Control Master 1000 range of control and indicating equipment (incorporating 1020 and 1010): RS Repeater 747a/R03 RS Repeater with LCD display 747a/R04 Lon Repeater with LCD display 747a/R05 Remote unit 747a/E01 Incorporating the following units: CE00503 2 Loop System sensor interface LPCB Ref. No.
747a/03
747a/R01
747a/R02
20
January 2009
SECTION 3: PART
CE00489 40W PSU and as optional modular units: CE00490 100W PSU CE00435A Lon high integrity isolator
Certificated with the following options from BS EN 54 Part 2: 7.8 Output to sounders 7.11 Delays to outputs 10 Test condition
Certificate No: 176b to EN 54-2: 1997 + A1: 2006 + A2: 2007 and EN 54-4: 1997 + A1: 2002 Certificated Products XFP502/H 2 loop, 32 zone analogue addressable control and indicating equipment using Hochiki Protocol, metal housing Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501202 XFP Hochiki 2 loop, main motherboard SPF0501200 Display board "keypad display" Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality. 2 loop, 32 zone analogue addressable control and indicating equipment using Hochiki Protocol, metal housing + Keyswitch Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501202 XFP Hochiki 2 loop, main motherboard SPF0501199 Display board "keyswitch display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: LPCB Ref. No. 176b/01
XFP502K/H
176b/01
January 2009
21
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products XFP502/X 1) Scope of approval does not include the operation of the network functionality. 2 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501201 XFP Apollo 2 loop, main motherboard SPF0501200 Display board "Keypad display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality. 2 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501201 XFP Apollo 2 loop, main motherboard SPF0501200 Display board "Keypad display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 2 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing + Keyswitch Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501201 XFP Apollo 2 loop, main motherboard SPF0501199 Display board "Keyswitch display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality. 2 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol + Keyswitch, metal housing Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501201 XFP Apollo 2 loop, main motherboard SPF0501199 Display board "Keyswitch display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter LPCB Ref. No. 176b/02
XFP502/X/CON
176b/02
XFP502K/X
176b/02
XFP502K/X/CON
176b/02
22
January 2009
SECTION 3: PART
Certificated Products 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 32 zone analogue addressable control and indicating equipment using Hochiki Protocol, metal housing Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501212 XFP Hochiki 1 loop, main motherboard SPF0501200 Display board "Keypad display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality. 1 Loop, 32 zone analogue addressable control and indicating equipment using Hochiki Protocol, metal housing + Keyswitch Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501212 XFP Hochiki 1 loop metal case, main motherboard SPF0501199 Display board "Keyswitch display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality. 1 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501211 XFP Apollo 1 loop, main motherboard SPF0501200 Display board "keypad display" Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality. 1 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501211 XFP Apollo 1 loop, main motherboard SPF0501200 Display board "keypad display" Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment LPCB Ref. No.
XFP501/H
176b/03
XFP501K/H
176b/03
XFP501/X
176b/04
XFP501/X/CON
176b/04
January 2009
23
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing + Keyswitch Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501211 XFP Apollo 1 loop, main motherboard SPF0501199 Display board "Keyswitch display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol + Keyswitch, metal housing Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501211 XFP Apollo 1 loop, main motherboard SPF0501199 Display board "Keyswitch display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 16 zone analogue addressable control and indicating equipment using Hochiki protocol, plastic housing Incorporating the following units: SPF0702480 Switch mode power supply board SPF0501102 XFP Hochiki 1 loop, main motherboard Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal -Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 16 zone analogue addressable control and indicating equipment using Hochiki protocol, plastic housing + Keyswitch Incorporating the following units: SPF0702480 Switch mode power supply board SPF1501102 XFP Hochiki 1 loop, main motherboard Certified with the following options with requirements from EN54-2: 1997 LPCB Ref. No.
XFP501K/X
176b/04
XFP501K/X/CON
176b/04
XFP501E/H
176b/05
XFP501EK/H
176b/05
24
January 2009
SECTION 3: PART
Certificated Products 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal -Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 16 zone analogue addressable control and indicating equipment using Apollo Protocol, plastic housing Incorporating the following units: SPF0702480 Switch mode power supply board SPF0501101 XFP Apollo 1 loop, main motherboard Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal -Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 16 zone analogue addressable control and indicating equipment using Apollo Protocol, plastic housing Incorporating the following units: SPF0702480 Switch mode power supply board SPF0501101 XFP Apollo 1 loop, main motherboard Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal -Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 16 zone analogue addressable control and indicating equipment using Apollo Protocol, plastic housing + Keyswitch Incorporating the following units: SPF0702480 Switch mode power supply board SPF1501101 XFP Apollo 1 loop, main motherboard Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal -Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality One Loop, 16 zone analogue addressable control and indicating equipment using Apollo Protocol, Plastic housing Incorporating the following units: SPF0702480 Switch mode power supply board LPCB Ref. No.
XFP501E/X
176b/06
XFP501E/X/CON
176b/06
XFP501EK/X
176b/06
XFP501KE/X/CON
176b/06
January 2009
25
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products SPF1 501101 XFP Apollo 1 loop, Main motherboard Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal -Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality LPCB Ref. No.
Certificate No: 176c to EN 54-2:1997 + A1:2006 + A2:2007 and EN 54-4:1997 + A1:2002 Certificated Products EP203 Incorporating the following units: SPF0000203 SPF0000212 SPF0003613 SPF0000214 Main extinguisher control External relay interface Power supply unit EP214 terminator LPCB Ref. No. 176c/01
Incorporating as modular units: EP210S EP211 Remote Status Unit Surface Mount optional (See Note 1) Economy Status Unit optional (See Note 1)
Certified with the following options with requirements from EN 12094-1:2003 4.17 4.18 4.19 4.20 4.21 4.23 4.26 4.27 4.30 Delay of extinguishing signal Signal representing the flow of extinguishing agent Monitoring of the status of components Emergency hold device Control of flooding time Manual only mode Triggering of equipment outside the system Emergency abort device Activation of alarm devices with different signals
Certified with the following options with requirements from EN-54-2:1997 7.8 Output to fire alarm device(s) 7.11 Delays to the auctioning of outputs fire alarm devices and fire routing equipment 7.13 Alarm counter 10 Test condition Notes: 1) Optional Remote Status Unit part No. EP21OS & Economy Status Unit part No. EP211 are not certified as meeting the requirements of the standards specified. 2) Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature range of -5C to +40C.
26
January 2009
SECTION 3: PART
Precept
018a/02
Precept
018a/03
Precept
018a/04
Precept
018a/05
Series 600
018a/06
Series 600
018a/07
Series 600
018a/08
Series 600
018a/09
Series 600
018a/10
Discovery
018c/01
018c/02
018c/03
January 2009
27
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 8 zone conventional control and indicating equipment Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 16 zone conventional control and indicating equipment Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 32 zone conventional control and indicating equipment Incorporating as modular units:C1627 Mother board C1629 Display board C1631 Repeater interface board (option) C1632 16 Zone Expansion board C1652 5A Power supply board 8 zone conventional repeater unit Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 16 zone conventional repeater unit Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 32 zone conventional repeater unit Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) LPCB Ref. No.
018c/04
018c/05
018c/06
018c/R01
018c/R02
018c/R03
Certificate Nos. 018a and 018c: Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition Certificate Nos. 018c/02-06: Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition
28
January 2009
SECTION 3: PART
UK Sales: Tel: +44 (0)1594 541900 Fax: +44 (0)1594 541910 E-mail: sales@cooperfire.co.uk Website: www.cooperfire.co.uk
Certificate No: 714a to EN 54 Part 2 and 4 :1997 Certificated Products CF3000 32 zone conventional repeater unit Incorporating the following units: ADF6 Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop card (2 off) ADF6 Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6DISPCOVER Display PCB Cover ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover ADF6PRINTER Printer YPCB2187 Fire Brigade Interface Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Analogue addressable 2 and 4 loop control and indicating equipment Incorporating the following units: ADF6 Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop card (2 off) ADF6Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6DISPCOVER Display PCB Cover ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover ADF6PRINTER Printer YPCB2187 Fire Brigade Interface Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment LPCB Ref. No. 714a/01
DF6000
714a/01
January 2009
29
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Analogue addressable 2 and 4 Loop control and indicating equipment Incorporating the following units: ADF6 Back Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop Card (2 off) ADF6Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6 DISPCOVER Display PCB Cover ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover ADF6PRINTER Printer YPCB2187 Fire Brigade Interface Certified with the following options with requirements from EN54-2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Analogue addressable 2 Loop control and indicating equipment Incorporating the following units: PR202-50-2209 Power supply board PR202-50-2206 Main motherboard PR202-50-2205 Display board Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition LPCB Ref. No.
FX6000
714a/01
CF2000
714a/02
30
January 2009
SECTION 3: PART
Certificated Products A1584 230Vac power supply control card A1599 Printer board Certified with the following options from EN54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 2 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 4 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 16 zone conventional control and indicating equipmentII Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 32 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1629 Display board C1632 16 Zone expansion board C1652 5A Power Supply board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional repeater unit Incorporating as modular units: LPCB Ref. No.
018c/02
018c/03
018c/04
018c/05
018c/06
018c/R01
January 2009
31
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products C1627 Mother board C1628 Display board C1631 Repeater interface 16 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 32 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1629 Display board C1631 Repeater interface LPCB Ref. No.
018c/R02
018c/R03
FX1
548j/02
FX2
548j/03
FX4
548j/04
FX8
548j/05
FX16
548j/06
32
January 2009
SECTION 3: PART
Certificated Products 10 Test condition LPCB Ref. No.
Certificate No: 092h to EN 54: Part 2 and 4:1997 Certificate No: 018c to EN 54: Part 2 and 4: 1997 Certificate No: 092e to BS 5839-4: 1988 This certificate is to a withdrawn standard. Control and indicating equipment conforming to this version of the standard is not suitable for use within the jurisdiction of the European Union (EU). This certification, to the withdrawn version of the standard, is maintained because control and indicating equipment meeting the withdrawn version of the standard is still requested by some regulators outside of the EU. Certificated Products ZC3-EN2 2 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 4 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certificated with the following options from EN 54-2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to fire protection equipment 7.11 Delays to outputs 8.9 Output to fault routing equipment 10 Test condition 8 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certificated with the following options from EN 54-2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to fire protection equipment 7.11 Delays to outputs 8.9 Output to fault routing equipment 10 Test condition 16 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certificated with the following options from EN 54-2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to fire protection equipment 7.11 Delays to outputs 8.9 Output to fault routing equipment 10 Test condition 32 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1629 Display board LPCB Ref. No. 018c/02
ZC3-EN4
018c/03
ZC3-EN8
018c/04
ZC3-EN16
018c/05
ZC3-EN32
018c/06
January 2009
33
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products C1632 16 Zone Expansion board C1652 5A Power supply board C1631 Repeater interface board (option) Certificated with the following options from EN 54-2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to fire protection equipment 7.11 Delays to outputs 8.9 Output to fault routing equipment 10 Test condition 8 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 16 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 32 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 2,4 and 8 loop analogue addressable control and indicating equipment Incorporating as modular units: ZP-PS230V4A-3 power supply unit ZP-MCB5 main control board ZP-LD8-4 line driver board ZP-DU81L-2 LCD ZP-DU81P-2 plasma display board ZP-PR1 printer kit ZP-RL8-1 8 way programmable relay board Note: This product is certificated to a withdrawn standard. Control and indicating equipment conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). The certification, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. 1, 2 and 4 loop analogue addressable control and indicating equipment Incorporating as modular units: ZP3-MB2-4L 4 Loop Main board ZP3-MB2-2L 2 Loop Main board ZP3-MB2-1L 1 Loop Main board ZP3-CPU1 CPU board ZP3-DB1 Display board ZP3-ZB50 50 Zone LED board ZP3-CB1 Commissioning key switch board ZP3-PR1 Printer Kit ZP3AB-SCB-D Control bus drive ZP3AB-RL8 Programmable relay output board, 8 way ZP3-AB-MA8 Programmable monitored output board, 8 way ZP3AB-OP24 Programmable transistor output board, 24 way ZP3AB-MIP8 Programmable input board, 8 way ZP3-xL 230V ac Power supply unit Approved with the following options from EN54-2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to fire protection equipment 7.11 Delays to outputs 7.12 Co-incidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault routing equipment 9.5 Disablement of addressable points 10.0 Test condition 11.0 Standardised input/output interface LPCB Ref. No.
ZC3-RDU230-8
018c/R01
ZC3-RDU230-16
018c/R02
018c/R03
ZP5 Mark 5
092e/01
ZP3
092h/01
34
January 2009
SECTION 3: PART
GE Security Inc
5 North Main Street, Pittsfield, ME 04967, USA Tel: +1 207 487 3104 Fax: +1 207 487 5526 E-mail: leon.newsome@ge.com Website: www.gesecurity.com
Certificate No: 262v to EN 54: Part 2 and 4: 1997 Certificated Products EST3 Control and indicating equipment Incorporating as modular units: 3-PPS/M 230E Primary power supply 3-BPS/M 230E Power supply booster 3-CPU Central processor module 3-LCD Main LCD display for 3 CPU1. 3-LDSM LED display support local rail module. 3-SSDC Single Signature driver controller module 3-AADC System Sensor driver controller module 3-IDC8/4 Traditional zone I/O module. 3-RS485 Network communications card 3-RS232 Ancillary communications card 3-24Y 24 yellow LED card 3-24R 24 red LED card 3-24RY 24 red/yellow LED card Repeater Incorporating as modular units: 3-ANNCPU1 Central Processor Module 3-LCD Main LCD Display for 3 CPU The following options with requirements are certified with this equipment: 7.8 Output to fire alarm devices 7.13 Alarm counter 8.3 Fault Signals from points. 10 Test condition LPCB Ref. No. 262v/01
EST3
262v/01
Gent By Honeywell
140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN UK Tel: +44 (0)116 246 2000 Fax: +44 (0)116 246 2300 E-mail: gent_enquiry@gent.co.uk Website: www.gent.co.uk Middle East Sales Enquiries E-mail: gent.export@honeywell.com
Certificate No: 042bb to EN 54-2:1997 and EN 54-4: 1997 Certificate No: 042x to EN 54: Parts 2 & 4: 1997
January 2009
35
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 2434-826 Addressable daughter speaker card (Optional Card)* 2434-780 Audio Input Card (Optional Card)* 2434-781 Audio Output Card (Optional Card)* Note: Scope of approval does not include the functionality of the network card and optional voice alarm system cards) 1 zone conventional control and indicating equipment Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition 2 zone conventional control and indicating equipment Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.9 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition 4 zone conventional control and indicating equipment Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.9 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition 8 zone conventional control and indicating equipment Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.9 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition Single loop analogue addressable control and indicating equipment Incorporating as modular units: 2434-334 Power supply PCB VIG-LPC 1 Loop processor card VIG-MCC Master Controller Card 2434-766 Display PCB 2434-578 Terminal PCB 2434-581 GENT backpanel VIG-IOC-DOM Output card 2434-591 Printer PCB VIG-NC-FO Fibre optic Network card Scope of approval does not include the operation of the network card) 2 loop analogue addressable control and indicating equipment Incorporating as modular units: 2434-334 Power supply PCB VIG-LPC 2 Loop processor card VIG-MCC Master controller card 2434-766 Display PCB 2434-578 Terminal PCB 2434-581 GENT backpanel VIG-IOC-DOM Output card 2434-591 Printer PCB VIG-NC-FO Fibre optic Network card Scope of approval does not include the operation of the network card) 3 loop analogue addressable control and indicating equipment Incorporating as modular units: 2434-334 Power supply PCB VIG-LPC 3 Loop processor card VIG-MCC Master controller card 2434-766 Display PCB 2434-578 Terminal PCB 2434-581 GENT backpanel VIG-IOC-DOM Output card 2434-591 Printer PCB VIG-NC-FO Fibre optic Network card Scope of approval does not include the operation of the network card) 4 loop analogue addressable control and indicating equipment Incorporating as modular units: 2434-334 Power supply PCB VIG-LPC 4 Loop processor card VIG-MCC Master controller card 2434-766 Display PCB 2434-578 Terminal PCB 2434-581 GENT backpanel VIG-IOC-DOM Output card 2434-591 Printer PCB LPCB Ref. No.
13270-01
042x/01
13270-02
042x/02
13270-04
042x/03
13270-08
042x/04
VIG 1
042x/06
VIG 2
042x/07
VIG 3
042x/08
VIG 4
042x/09
36
January 2009
SECTION 3: PART
Certificated Products VIG-NC-FO Fibre optic Network card Scope of approval does not include the operation of the network card) Incororating as modular units: 2434-824 Power supply 2434-710 Loop Processor card 2434-833 Master Control card 2434-825 Optical Network card* 2434-821 Message Store card* 2434-822 Mother board 2434-835 H.M.I. 2434-840 Cold fire card 2434-796 Addressable speak card (Optional Card)* 2434-826 Addressable daughter speaker card (Optional Card)* 2434-780 Audio Input Card (Optional Card)* 2434-781 Audio Output Card (Optional Card)* (*Note: Scope of approval does not include the functionality of the network card and optional voice alarm system cards) Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition LPCB Ref. No.
Certificate No: 042d to BS 5839-4: 1988 This certificate is to a withdrawn standard. Control and indicating equipment conforming to this version of the standard is not suitable for use within the jurisdiction of the European Union (EU). This certification, to the withdrawn version of the standard, is maintained because control and indicating equipment meeting the withdrawn version of the standard is still requested by some regulators outside of the EU. Certificated Products 3404 Control and indicating equipment Incorporating as modular units13430-01V3 Local Controller Card (LCC)13431-01V3 Loop Processor Card (LPC)13432-03V3 Input Output Card (IOC)13433-01V3 Random Access Memory (RAM) card 1 loop control and indicating equipment Note: This product is certificated to a withdrawn standard. Control and indicating equipment conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). The certification, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. 2 loop control and indicating equipment Note: This product is certificated to a withdrawn standard. Control and indicating equipment conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). The certification, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. 3 loop control and indicating equipment Note: This product is certificated to a withdrawn standard. Control and indicating equipment conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). The certification, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. 4 loop control and indicating equipment Incorporating as modular units: VIG-LCC V3+ Loop Controller Card (LCC) VIG-LPC V3+ Loop Processor Card (LPC) VIG-IOC V3+ Input Output Card (IOC) VIG-RAM Random Access Memory Card (RAM) Note: This product is certificated to a withdrawn standard. Control and indicating equipment conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). The certification, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. LPCB Ref. No. 042d/05
VIG1-V3+
042d/07
VIG2-V3+
042d/08
VIG3-V3+
042d/09
VIG4-V3+
042d/10
January 2009
37
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificate No: 042at Certificated Products 8000 M 7 loop analogue addressable control and indicating equipment Incorporating as modular units: 771690 Power Supply Module 772414 Basic Module 772441 Display Card 772411 LED Module 772412 Group Individual Indication 128 Zones 772413 Group Individual Indication 384 Zones 772418 Peripheral Module 772419 Peripheral Module 772420 Peripheral Module 772421 Extension Module 787530 4 Relay Module 787531 3 Relay Module 787532 3 Relay SaS Module 787533 BSL Module 787680 7 Output Module Positive 787681 7 Output Module Negative 784382 Analogue Ring Module 784385 CIE Triggering Module 802426 Powered Loop power pack module 804382 Analogue Ring Module powered loop 804383 Analogue Ring Module powered loop Approved with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing devices 7.10 Output to automatic fire protection equipment 7.12 Coincidence detection 7.13 Alarm counter 8.4 Total loss of the power supply 10 Test Condition 11 Output to standardised input/output interface 2 loop analogue addressable control and indicating equipment Incorporating as modular units: 771690 Power Supply Module 772414 Basic Module 772441 Display Card 772411 LED Module 772412 Group Individual Indication 128 Zones 772413 Group Individual Indication 384 Zones 772418 Peripheral Module 772419 Peripheral Module 772420 Peripheral Module 787530 4 Relay Module 787531 3 Relay Module 787532 3 Relay SaS Module 787533 BSL Module 787680 7 Output Module Positive 787681 7 Output Module Negative 784382 Analogue Ring Module 784385 CIE Triggering Module 802426 Powered Loop power pack module 804382 Analogue Ring Module powered loop 804383 Analogue Ring Module powered loop Approved with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing devices 7.10 Output to automatic fire protection equipment 7.12 Coincidence detection 7.13 Alarm counter 8.4 Total loss of the power supply 10 Test Condition 11 Output to standardised input/output interface LPCB Ref. No. 042at/01
8000 C
042at/02
38
January 2009
SECTION 3: PART
GST 101
548j/02
GST 102
548j/03
GST 104
548j/04
GST 108
548j/05
GST 116
548j/06
January 2009
39
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Premier SX Premier SX Premier SX Premier SX Premier SX 1 zone conventional control and indicating equipment 2 zone conventional control and indicating equipment 4 zone conventional control and indicating equipment 6 zone conventional control and indicating equipment 8 zone conventional control and indicating equipment Certified with the following options with requirements from EN 54: Part 2: 7.8 Output to fire alarm devices 7.11 Delays to the actioning of outputs 10 Test condition 2 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 4 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 16 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 32 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1629 Display board C1632 16 Zone expansion board C1652 5A Power Supply board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional repeater unit LPCB Ref. No. 330d/01 330d/02 330d/03 330d/04 330d/05
Premier MX
330d/06
Premier MX 4
330d/07
Premier MX 8
330d/08
Premier MX 16
330d/09
Premier MX 32
330d/10
Premier MX Repeater 8
330d/R01
40
January 2009
SECTION 3: PART
Certificated Products Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 16 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 32 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1629 Display board C1631 Repeater interface LPCB Ref. No.
Premier MX Repeater 16
330d/R02
Premier MX Repeater 32
330d/R03
Certificate No: 018c to EN 54-2 and 4:1997 Certificated Products Prem1er AL 4 loop analogue addressable control and indicating equipment Incorporating: A1579 Motherboard A1580 Display board A1585 Loop cards A1584 230V AC power supply control card A1599 Printer board Certified with the following options from EN 54:Part 2 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition LPCB Ref. No. 018c/01
January 2009
41
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 8.3 Fault signals from points 9.5 Disablement of addressable points Single zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Two zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Four zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Eight zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Sixteen zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition LPCB Ref. No. 548j/02
GS101
GS102
548j/03
GS104
548j/04
GS108
548j/05
GS116
548j/06
Gulf Security Technology Co. Ltd (Manufacturing Division of Global System Technology PLC)
No. 80 Changjiang East Road, Economic & Technological Development Zone, Qinhuangdao, Hebei Province 066004, Peoples Republic of China Tel: +86 0335 8502528 Fax: +86 0335 8508942 E-mail: gst@gst.com.cn Website: www.gst.com.cn Sales Beijing: Tel: +86 (10) 6439 1866 Fax: +86 (10) 6439 1787
Sales Hong Kong: Tel: +852 2877 8566 Fax: +852 2511 8699
Certificate No: 548j to EN 54-2:1997 & EN54-4:1997 Certificated Products GST-200 Intelligent 1 loop, 30 zone, analogue addressable control and indicating equipment Incorporating the following units: F7.820.826 Main board F7.908.312 Zone indication board F7.820.827 Switch board F7.820.828 Loop interface board F7.820.829 Power Supply unit F2.910.093 Mains filter R150 Transformer CGM12864 Alphanumeric Display F2.828.630a Printer board (option) Incorporating as optional modular units: P-9901 Printer module kit F7.820.170 RS232 board for configuration Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10 Output to automatic Fire Protection Equipment LPCB Ref. No. 548j/01
42
January 2009
SECTION 3: PART
Certificated Products 7.11 Delays to outputs 7.12 Coincidence detection 8.3 Fault signals from points 9.5 Disablement of addressable points Single zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Two zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Four zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Eight zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Sixteen zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition LPCB Ref. No.
GST 101
548j/02
GST 102
548j/03
GST 104
548j/04
GST 108
548j/08
GST 116
548j/09
Sirius II SE2000
054d/05
January 2009
43
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
ZX5e
429a/02
320b
429a/05
380b
429a/06
44
January 2009
SECTION 3: PART
Certificated Products 124-336 Loop base card 124-335 Display card 124-337 Printer module (DX1e-40MP only) Note: The CIE is compatible with Apollo, Hochiki and System sensor protocols 1 loop 20 zone, analogue addressable control indicating equipment. Incorporating the following units: 124-336 Loop base card 124-335 Display card Note: The CIE is compatible with Apollo, Hochiki and System sensor protocols 2 loop, 40 zone, analogue addressable control indicating equipment Incorporating the following units: 124-344 Loop base card 124-335 Display card 124-337 Printer module (DX2e-40MP and DX2e-40LP only) Note: The CIE is compatible with Morley protocol 2 loop, 40 zone, analogue addressable control indicating equipment Incorporating the following units: 124-344 Loop base card 124-335 Display card 124-337 Printer module (DX2e-40MP and DX2e-40LP only) Note: The CIE is compatible with Apollo, Hochiki and System sensor protocols 4 loop, 40 zone, analogue addressable control indicating equipment Incorporating the following units: 124-344 Loop base card 124-351 Two loop plug in cards 124-335 Display card 124-337 Printer module (DX4e-40LP only) Note: The CIE is compatible with Apollo, Hochiki and System sensor protocols The DX model range Certified with the following options with requirements from EN 54 part 2: 7.8 7.11 7.12 8.3 9.5 Output to fire alarm devices Delays to outputs Coincidence detection Fault signals from points Disablement of addressable points 10 Test condition LPCB Ref. No.
DXIe-206
429a/07
DX2e-40L-M
429a/08
DX2e-40M
429a/08
DX4e-40L
429a/09
All of the above are certified with the following options with requirements from EN 54: Part 2 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12 Coincidence detection 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition
Certificate No: 154d to EN 54:Part 2 and 4: 1997 Certificated Products Horizon HRZ2-8 Horizon HRZ2-8 Horizon HRZ2-8 HRZ2-8 002-479-322 Morley-IAS Horizon, 2 zone, dual relay, Danish, Finish, Norwegian, Swedish (Region 3) 002-492-222 Morley-IAS Horizon, 2 zone, 2w relay, English, French, Spanish, Portuguese, Italian (Region 2) + UK user manual 002-506-222 Morley-IAS Horizon, 2 zone, English, French, Spanish, Portuguese, Italian (Region 2) + UK user manual Horizon 2 Zone conventional control and indicating equipment Including the following versions: 002-479-122 Language region 1, English manual 002-479-222 Language region 2 002-479-322 Language region 3, dual relay 002-492-222 Language region 2, dual relay, English manual 002-506-222 Language region 2, English manual 002-479-342 Morley-IAS Horizon, 4 zone, dual relay, Danish, Finish, Norwegian, Swedish (Region 3) 002-492-242 Morley-IAS Horizon, 4 zone, 2w relay, English, French, Spanish, LPCB Ref. No. 154d/09 154d/09 154d/09 154d/09
154d/10 154d/10
January 2009
45
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Horizon HRZ2-8 HRZ2-8 Portuguese, Italian (Region 2) + UK user manual 002-506-242 Morley-IAS Horizon, 4 zone, English, French, Spanish, Portuguese, Italian (Region 2) + UK user manual Horizon 4 zone conventional control and indicating equipment Including the following versions: 002-479-142 Language region 1, English manual 002-479-242 Language region 2 002-479-342 Language region 3, dual relay 002-492-242 Language region 2, dual relay, English manual 002-506-242 Language region 2, English manual 002-479-382 Morley-IAS Horizon, 8 zone, dual relay, Danish, Finish, Norwegian, Swedish (Region 3) 002-492-282 Morley-IAS Horizon, 8 zone, 2w relay, English, French, Spanish, Portuguese, Italian (Region 2) + UK user manual 002-506-282 Morley-IAS Horizon, 8 zone, English, French, Spanish, Portuguese, Italian (Region 2) + UK user manual Horizon 8 zone conventional control and indicating equipment Including the following versions: 002-479-182 Language region 1, English manual 002-479-282 Language region 2 002-479-382 Language region 3, dual relay 002-492-282 Language region 2, dual relay, English manual 002-506-282 Language region 2, English manual The HRZ model range Certified with the following options with requirements from EN 54 part 2: 7.8 7.9 7.11 7.12 10 Output to fire alarm devices Output to fire routing equipment Delays to outputs Coincidence detection Test condition LPCB Ref. No. 154d/10 154d/10
Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 10 Test condition
46
January 2009
SECTION 3: PART
Certificated Products F2.828.630a Printer board (option) Incorporating as optional modular units: P-9901 Printer module kit F7.820.170 RS232 board for configuration Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10 Output to automatic Fire Protection Equipment 7.11 Delays to outputs 7.12 Coincidence detection 8.3 Fault signals from points 9.5 Disablement of addressable points Single zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Two zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Four zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Eight zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Sixteen zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition LPCB Ref. No.
NGSG101
548j/02
NGSG102
548j/03
NGSG104
548j/04
NGSG108
548j/05
NGSG116
548j/06
NV 2
018c/02
January 2009
47
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 4 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options with requirements from EN54-2: 1997: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options with requirements from EN54-2: 1997: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 16 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options with requirements from EN54-2: 1997: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 32 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1629 Display board C1632 16 Zone expansion board C1652 5A Power supply board C1631 Repeater interface (option) Certified with the following options with requirements from EN54-2: 1997: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 16 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 32 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface LPCB Ref. No.
NV 4
018c/03
NV 8
018c/04
NV 16
018c/05
NV 32
018c/06
NV 8R
018c/R01
NV 16R
018c/R02
NV 32R
018c/R03
48
January 2009
SECTION 3: PART
Notifier By Honeywell
Charles Avenue, Burgess Hill, West Sussex RH15 9UF UK Tel: +44 (0)1444 230300 Fax: +44 (0)1444 230888 E-mail: sales@notifiersystems.co.uk Website: www.notifierfiresystems.co.uk
Certificate No: 154d to EN 54: Part 2 and 4: 1997 Certificated Products ID2000 2-8 loop analogue addressable control and indicating equipment 020-628 Language Group 0 basic equipment kit 020-628-001 Language Group 1 basic equipment kit Fixed 2 loop analogue addressable control and indicating equipment 002-459 Language Group 0 002-459-001 Language Group 1 002-472 Languarge Group 0, red cover Incorporating as modular units: 020-469-009 Extension Chassis with 17-80 Zone LED Display 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588 LIB, Loop Interface Board 020-478 RS232 Communications Kit 020-479 RS485 Communications Kit 020-484 PSU2.5A Power Supply 020-648 PSU3A Power Supply 020-579 PSU7A Power Supply (Requires DTP / Booster Interface) 020-543 DTP Dual Transmission Path / Booster Interface 020-541-009 78Ah Battery and PSU7A Enclosure 020-472-009 Standard Back Box Kit 020-473-009 Extended Back Box Kit 020-474-009 Extended Deep Back Box Kit 020-475-009 Double Extended Back Box Kit 020-476-009 Double Extended Deep Back Box Kit 020-508-009 Standard Back Box Extension Kit 020-509-009 Deep Back box Extension Kit 020-480-009 Main Cover Kit 020-481-009 Extension Cover Kit 020-513-009 High Security Main Cover 020-514-009 High Security Extension Cover Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 2-8 loop analogue addressable control and indicating equipment 002-538 Language Group 0 basic equipment kit 020-538-001 Language Group 1 basic equipment kit Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to Fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Fixed 2 loop analogue addressable control and indicating equipment 002-474 Language Group 0 002-474-001 Language Group 1 LPCB Ref. No. 154d/01
ID2002
154d/01
ID3000
154d/02
ID3002
154d/02
January 2009
49
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 002-473 Language Group 0, red cover LPCB Ref. No. Incorporating as modular units: 020-559-001 Extension Chassis with 1-64 Zone LED Display 020-559-002 Extension Chassis with 65-128 Zone LED Display 020-612 Extension Chassis with 1-256 Zone LED Display 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588 LIB Loop Interface Board 020-549 ELIB, Enhanced Loop Interface Board 020-478 RS232 Communications Kit 020-479 RS485 Communications Kit 020-484 PSU2.5A Power Supply 020-648 PSU3A Power Supply 020-579 PSU7A Power Supply (Requires DTP / Booster Interface) 020-543 DTP Dual Transmission Path / Booster Interface 020-541-009 78Ah Battery and PSU7A Enclosure 020-472-009 Standard Back Box Kit 020-473-009 Extended Back Box Kit 020-474-009 Extended Deep Back Box Kit 020-475-009 Double Extended Back Box Kit 020-476-009 Double Extended Deep Back Box Kit 020-508-009 Standard Back Box Extension Kit 020-509-009 Deep Backbox Extension Kit 020-480-009 Main Cover Kit 020-481-009 Extension Cover Kit 020-513-009 High Security Main Cover 020-514-009 High Security Extension Cover 020-621-009 256 Zone LED Display Cover 020-647 NGM ID2net Network Gateway Module 020-643 Fibre Optic Interface Module 2 Zone conventional control and Indicating equipment 002-477-129 Notifier 2 zone, English, French, German, Dutch, Swedish, Icelandic (Region 1) 2 Zone conventional control and Indicating equipment 002-477-229 Notifier 2 zone, English, French, Spanish, Portuguese, Italian (Region 2) 2 Zone conventional control and Indicating equipment 002-477-329 Notifier 2 zone, dual relay, Danish, Finish, Norwegian, Swedish (Region 3) 2 Zone conventional control and Indicating equipment 002-490-129 Notifier 2 zone, dual relay, English, French, German, Dutch, Swedish, Icelandic (Region 1) + UK user manual 2 Zone conventional control and Indicating equipment 002-490-229 Notifier 2 zone, dual relay, English, French, Spanish, Portuguese, Italian (Region 2) + UK user manual 4 Zone conventional control and Indicating equipment 002-477-149 Notifier 4 zone, English, French, German, Dutch, Swedish, Icelandic (Region 1) 4 Zone conventional control and Indicating equipment 002-477-249 Notifier 4 zone, English, French, Spanish, Portuguese, Italian (Region 2) 4 Zone conventional control and Indicating equipment 002-477-349 Notifier 4 zone, dual relay, Danish, Finish, Norwegian, Swedish (Region 3) 4 Zone conventional control and Indicating equipment 002-490-149 Notifier 4 zone, dual relay, English, French, German, Dutch, Swedish, Icelandic (Region 1) + UK user manual 4 Zone conventional control and Indicating equipment 002-490-249 Notifier 4 zone, dual relay, English, French, Spanish, Portuguese, Italian (Region 2) + UK user manual 8 Zone conventional control and Indicating equipment 002-477-189 Notifier 8 zone, English, French, German, Dutch, Swedish, Icelandic (Region 1) 8 Zone conventional control and Indicating equipment 002-477-289 Notifier 8 zone, English, French, Spanish, Portuguese, Italian (Region 2) 8 Zone conventional control and Indicating equipment 002-477-389 Notifier 8 zone, dual relay, Danish, Finish, Norwegian, Swedish (Region 3) 8 Zone conventional control and Indicating equipment 002-490-189 Notifier 8 zone, dual relay, English, French, German, Dutch, Swedish, Icelandic (Region 1) + UK user manual 8 Zone conventional control and Indicating equipment 002-490-289 Notifier 8 zone, dual relay, English, French, Spanish, Portuguese, Italian (Region 2) + UK user manual Network Gateway Unit
NFS2-8 NFS2-8 NFS2-8 NFS2-8 NFS2-8 NFS2-8 NFS2-8 NFS2-8 NFS2-8 NFS2-8 NFS2-8 NFS2-8 NFS2-8 NFS2-8 NFS2-8 002-467 NGU, ID(2)net
154d/09 154d/09 154d/09 154d/09 154d/09 154d/10 154d/10 154d/10 154d/10 154d/10 154d/11 154d/11 154d/11 154d/11 154d/11 154d/N02
50
January 2009
SECTION 3: PART
Certificated Products Incorporating the following modular units, is approved for use with the ID3000 control and indicating equipment: 2 020-647 NGM, ID net Network Gateway Module 020-643 Fibre Optic Interface Module 020-648 PSU3A Power Supply Module ID300x panel and associated units are certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition Single loop analogue addressable control and indicating equipment Incorporating the following units: 002-455 Language Group 0, 1.5A PSU, 12Ah batteries 002-455-001 Language Group 1, 1.5A PSU, 12Ah batteries 020-553 RS485 Communication Kit Single loop analogue addressable control and indicating equipment Incorporating the following units: 002-462 Language Group 0, 3A PSU, 12Ah Batteries, Printer Option 002-462-001 Language Group 1, 3A PSU, 12Ah Batteries, Printer Option 020-553 RS485 Communication Kit 020-644-009 PRN-ID Printer Kit Single loop analogue addressable control and indicating equipment Incorporating the following units: 002-460 Language Group 0, 3A PSU, 42Ah Batteries, Printer Option 002-460-001 Language Group 1, 3A PSU, 42Ah Batteries, Printer Option 020-553 RS485 Communication Kit 020-644-009 PRN-ID Printer Kit Single loop analogue addressable control and indicating equipment Incorporating the following units: 002-456 Language Group 0, 1.5A PSU, 12Ah batteries, VIEW 002-456-001 Language Group 1, 1.5A PSU, 12Ah batteries, VIEW 020-553 RS485 Communication Kit Single loop analogue addressable control and indicating equipment Incorporating the following units: 002-463 Language Group 0, 3A PSU, 42Ah Batteries, VIEW, Printer Option 002-463-001 Language Group 1, 3A PSU, 12Ah Batteries, VIEW, Printer Option 020-553 RS485 Communication Kit 020-644-009 PRN-ID Printer Kit Single loop analogue addressable control and indicating equipment Incorporating the following units: 002-461 Language Group 0, 3A PSU, 42Ah Batteries, VIEW, Printer Option 002-461-001 Language Group 1, 3A PSU, 42Ah Batteries, VIW, Printer Option 020-553 RS485 Communication Kit 020-644-009 PRN-ID Printer Kit The ID5x/6x models are certified with the following options with requirements from EN 54 part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm Counter 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 2 Zone conventional control and indicating equipment Including the following versions: 002-477-122 Language region 1, light grey 002-477-129 Language region 1, black & grey 002-490-222 Language region 2, light grey 002-477-229 Language region 2, black & grey 002-477-322 Language region 3, light grey, dual relay 002-477-329 Language region 3, black & grey, dual relay, English manual 002-490-129 Language region 1, black & grey, dual relay, English manual 002-490-229 Language region 2, black & grey, dual relay, English manual 002-490-222 Language region 2, light grey, English manual 4 Zone conventional control and indicating equipment LPCB Ref. No.
ID50
154d/03
ID51
154d/04
ID52
154d/05
ID60
154d/06
ID61
154d/07
ID62
154d/08
NFS2-8
154d/09
NFS2-8
154d/10
January 2009
51
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Including the following versions: 002-477-142 Language region 1, light grey 002-477-149 Language region 1, black & grey 002-490-242 Language region 2, light grey 002-477-249 Language region 2, black & grey 002-477-342 Language region 3, light grey, dual relay 002-477-349 Language region 3, black & grey, dual relay, English manual 002-490-149 Language region 1, black & grey, dual relay, English manual 002-490-249 Language region 2, black & grey, dual relay, English manual 002-490-242 Language region 2, light grey, English manual 8 Zone conventional control and indicating equipment Including the following versions: 002-477-182 Language region 1, light grey 002-477-189 Language region 1, black & grey 002-477-282 Language region 2, light grey 002-477-289 Language region 2, black & grey 002-477-382 Language region 3, light grey, dual relay 002-477-389 Language region 3, black & grey, dual relay, English manual 002-490-189 Language region 1, black & grey, dual relay, English manual 002-490-289 Language region 2, black & grey, dual relay, English manual 002-490-282 Language region 2, light grey, English manual LPCB Ref. No.
NFS2-8
154d/11
The NFS2-8 (2-8 zones) panels are certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 10 Test condition
Certificate No: 154f to ISO 7240: Part 2 & 4: 2003 Certificated Products NFS2-8 2 zone conventional control and indicating equipment Including the following versions: 002-477-122 Language region 1, light grey 002-477-129 Language region 1, black & grey 002-477-222 Language region 2, light grey 002-477-229 Language region 2, black & grey 002-477-322 Language region 3, light grey, dual relay 002-477-329 Language region 3, black & grey, dual relay, English manual 002-490-129 Language region 1, black & grey, dual relay, English manual 002-490-229 Language region 2, black & grey, dual relay, English manual 002-490-222 Language region 2, light grey, English manual 4 zone conventional control and indicating equipment Including the following versions: 002-477-142 Language region 1, light grey 002-477-149 Language region 1, black & grey 002-477-242 Language region 2, light grey 002-477-249 Language region 2, black & grey 002-477-342 Language region 3, light grey, dual relay 002-477-349 Language region 3, black & grey, dual relay, English manual 002-490-149 Language region 1, black & grey, dual relay, English manual 002-490-249 Language region 2, black & grey, dual relay, English manual 002-490-242 Language region 2, light grey, English manual 8 zone conventional control and indicating equipment Including the following versions: 002-477-182 Language region 1, light grey 002-477-189 Language region 1, black & grey 002-477-282 Language region 2, light grey LPCB Ref. No. 154f/01
NFS2-8
154f/02
NFS2-8
154f/03
52
January 2009
SECTION 3: PART
Certificated Products Language region 2, black & grey Language region 3, light grey, dual relay Language region 3, black & grey, dual relay, English manual 002-490-189 Language region 1, black & grey, dual relay, English manual 002-490-289 Language region 2, black & grey, dual relay, English manual 002-490-282 Language region 2, light grey, English manual The NFS2-8 (2 -8 zones) panels are certified with the following options from ISO 7240 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Dependency detection 11 Test condition 002-477-289 002-477-382 002-477-389 LPCB Ref. No.
Novar GmbH
Security and Building Management Systems, Dieseltrasse 2, D-41469, Neuss, Germany Tel: +49 (0)2137 170 Fax: +49 (0)2137 17286 E-mail: info@esser-systems.de Website: www.esser-systems.de
Certificate No: 400f to EN 54: Part 2 and 4: 1997 Certificated Products 8000M 7 loop analogue addressable control and indicating equipment Incorporating as modular units 771690 Power Supply Module 772414 Basic Module 772441 Display Card 772411 LED Module 772412 Group Individual Indication 128 Zones 772413 Group Individual Indication 384 Zones 772418 Peripheral Module 772419 Peripheral Module 772420 Peripheral Module 772421 Extension Module 787530 4 Relay Module 787531 3 Relay Module 787532 3 Relay SaS Module 787533 BSL Module 787680 7 Output Module Positive 787681 7 Output Module Negative 784382 Analogue Ring Module 784385 CIE Triggering Module 802426 Powered Loop power pack module 804382 Analogue Ring Module powered loop 804383 Analogue Ring Module powered loop 2 loop analogue addressable control and indicating equipment Incorporating as modular units 771690 Power Supply Module 772441 Display Card 772411 LED Module 772412 Group Individual Indication 128 Zones 772413 Group Individual Indication 384 Zones 772414 Basic Module 772418 Peripheral Module 772419 Peripheral Module 772420 Peripheral Module 787530 4 Relay Module 787531 3 Relay Module 787532 3 Relay SaS Module 787533 BSL Module 787680 7 Output Module Positive LPCB Ref. No. 400f/01
8000C
400f/02
January 2009
53
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 787681 7 Output Module Negative 784382 Analogue Ring Module 784385 CIE Triggering Module 802426 Powered Loop power pack module 804382 Analogue Ring Module powered loop 804383 Analogue Ring Module powered loop 7 loop analogue addressable control and indicating equipment Incorporating as modular units 772441 Display Card 772411 LED Module 772412 Group Individual Indication 128 Zones 772413 Group Individual Indication 384 Zones 808004 Base package IQ8Control M 772480 Interface (IF)-Board IQ8Control X 772482 Interface (IF)-Board IQ8Control M 772485 CPU-Module CF Processor 772477 Peripheral Module 772478 Peripheral Module 772479 Peripheral Module 772476 Extension Module 787530 4 Relay Module 787531 3 Relay Module 787532 3 Relay SaS Module 787533 BSL Module 787680 7 Output Module Positive 787681 7 Output Module Negative 784382 Analogue Ring Module 784385 CIE Triggering Module 802426 Powered Loop power pack module 804382 Analogue Ring Module powered loop 804383 Analogue Ring Module powered loop 784842 RS232/TTY Module 2 loop analogue addressable control and indicating equipment Incorporating as modular units 772441 Display Card 772411 LED Module 772412 Group Individual Indication 128 Zones 772413 Group Individual Indication 384 Zones 808003 Base package IQ8Control C 772480 Interface (IF)-Board IQ8Control X 772481 Interface (IF)-Board IQ8Control C 772485 CPU-Module CF Processor 772477 Peripheral Module 772478 Peripheral Module 772479 Peripheral Module 787530 4 Relay Module 787531 3 Relay Module 787532 3 Relay SaS Module 787533 BSL Module 787680 7 Output Module Positive 787681 7 Output Module Negative 784382 Analogue Ring Module 784385 CIE Triggering Module 802426 Powered Loop power pack module 804382 Analogue Ring Module powered loop 804383 Analogue Ring Module powered loop 784842 RS232/TTY Module LPCB Ref. No.
IQ8 Control M
400f/03
IQ8 Control C
400f/04
Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing devices 7.10 Output to automatic fire protection equipment 7.12 Coincidence detection 7.13 Alarm counter 8.4 Total loss of the power supply 10 Test Condition 11 Output to standardised input/output interface
54
January 2009
SECTION 3: PART
Pelco Finland Oy
Kalkkipellontie 6, 02650 Espoo, Finland Tel: +358 10 446 511 Fax: +358 10 446 5103
Certificate No: 883a to EN 54-2 :1997 & EN 54-4 :1997 Certificated Products FX 8 Loop Analogue addressable CIE Basic unit incorporate the following modules: FX-MC FX-UI FX-PSB or FX-PSA Master controller User interface 4.5 A Power Supply 2.2 A Power Supply LPCB Ref. No. 883a/01
Optional Modules -The following modules are optional additions to the basic unit: FX-ALCB FX-ALCA FX-LC FX-CLC FX-IOC FX-SAA Two loop addressable controller - Apollo protocol card One loop addressable controller - Apollo protocol card Two loop addressable controller - System sensor protocol card Sixteen loop conventional Controller I/O controller board Serial communications adapter for communication with external systems
(BSM or Alarm Management Systems). FX-SAB Serial communications adapter for communication in a networked FX system and with external systems (BSM or Alarm Management Systems). FX-LB80 80 Zone LED indication card FX-LB32 32 Zone LED indication card FX-BAT Separate battery box (4x17Ah, 12V) FXM-BAT Separate battery box (4x12Ah, 12V) Certified with the following options with requirements from EN 54-2:1997 7.8 Outputs to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to Fire Protection Equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.4 Complete failure of power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 8 Loop Analogue addressable CIE Basic unit incorporate the following modules: FX-MC Master controller FX-UI User interface FX-PSB 4.5 A Power Supply or FX-PSA 2.2 A Power Supply Optional Modules - The following modules are optional additions to the basic unit: FX-ALCB Two loop addressable controller - Apollo protocol card FX-ALCA One loop addressable controller - Apollo protocol card FX-LC Two loop addressable controller - System sensor protocol card FX-CLC Sixteen loop conventional Controller FX-IOC I/O controller board FX-SAA Serial communications adapter for communication with external systems (BSM or Alarm Management Systems). FX-SAB Serial communications adapter for communication in a networked FX system and with external systems (BSM or Alarm Management Systems).
FXL
883a/02
January 2009
55
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products FX-LB80 80 Zone LED indication card FX-LB32 32 Zone LED indication card FX-BAT Separate battery box (4x17Ah, 12V) FXM-BAT Separate battery box (4x12Ah, 12V) Certified with the following options with requirements from EN 54-2:1997 7.8 Outputs to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to Fire Protection Equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.4 Complete failure of power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality. 4 Loop Analogue addressable CIE Basic unit incorporate the following modules: FX-MC Master Controller FX-UI User Interface FX-PSB 4.5 A Power Supply or FX-PSA 2.2 A Power Supply Optional Modules -The following modules are optional additions to the basic unit: FX-ALCB FX-ALCA FX-LC FX-CLC FX-IOC FX-SAA Two loop addressable controller - Apollo protocol card One loop addressable controller - Apollo protocol card Two loop addressable controller - System sensor protocol card Sixteen loop conventional Controller I/O controller board Serial communications adapter for communication with external systems LPCB Ref. No.
FXM
883a/03
(BSM or Alarm Management Systems) FX-SAB Serial communications adapter for communication in a networked FX system and with external systems (BSM or Alarm Management Systems). FX-LB80 80 Zone LED indication card FX-LB32 32 Zone LED indication card FX-BAT Separate battery box (4x17Ah, 12V) FXM-BAT Separate battery box (4x12Ah, 12V) Certified with the following options with requirements from EN 54-2:1997 7.8 Outputs to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to Fire Protection Equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.4 Complete failure of power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality. Analogue addressable Repeater Panel Incorporating the following modules: FX-MC Master Controller FX-UI User Interface Optional Modules -The following modules are optional additions to the basic unit: FX-IOC I/O Controller
FXS
883a/R01
56
January 2009
SECTION 3: PART
6302
201k/02
6304
201k/03
6400/DCN
201k/04
January 2009
57
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units: 6400/DCN Display and Control node 6400/PSU 8A Power supply with charger 2) Scope of approval does not include the operation of the network functionality. 2 loop processing node Incorporating the following units: WEFA 169E2 SSU WEFA 315B Dual loop driver WEFA 160D Local IO WEFA 230C Terminal board WEFA 232C Loop terminal board WEFA 237A LPN display board WEFA 288C OPTO 485 board Notes: 1) This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units: 6400/DCN Display and Control node 6400/PSU 8A Power supply with charger 2) Scope of approval does not include the operation of the network functionality. 4 loop processing node Incorporating the following units: WEFA 169E2 SSU WEFA 315B 2 x Dual loop driver WEFA 160D Local IO WEFA 230C Terminal board WEFA 232C Loop terminal board WEFA 237A LPN display board WEFA 288C OPTO 485 board Notes: 1) This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units: 6400/DCN Display and Control node 6400/PSU 8A Power supply with charger 2) Scope of approval does not include the operation of the network functionality. Display and control node plus 2 Loop processing node Incorporating the following units: WEFA 312E Display control unit WEFA 168E Local display unit WEFA 169E2 SSU WEFA 315B Dual loop driver WEFA 160D Local IO WEFA 230C Terminal board WEFA 232C Loop terminal board WEFA 288C OPTO 485 board Certified with the following options with requirements from EN 54: Part 2: 1997: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.11 Delays of the actioning of outputs to fire alarm devices and fire alarm routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Notes: 1) This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following unit: 6400/PSU 8A Power supply with charger 2) Scope of approval does not include the operation of the network functionality. LPCB Ref. No.
6400/2LPN
201k/05
6400/4LPN
201k/06
6400/DCN/2LPN
201k/07
58
January 2009
SECTION 3: PART
Certificated Products 6400/DCN/4LPN Display and control node plus 4 Loop processing node Incorporating the following units: WEFA 312E Display control unit WEFA 168E Local display unit WEFA 169E2 SSU WEFA 315B 2 x Dual loop driver WEFA 160D Local IO WEFA 230C Terminal board WEFA 232C Loop terminal board WEFA 288C OPTO 485 board Certified with the following options with requirements from EN 54: Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.11 Delays of the actioning of outputs to fire alarm devices and fire alarm routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Notes: 1) This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following unit: 6400/PSU 8A Power supply with charger 2) Scope of approval does not include the operation of the network functionality. Power supply with charger Incorporating the following unit: 9000/BC8/40 8A Power supply with charger Notes: 1) This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units: 6400/DCN Display and Control node 6400/2LPN 2 Loop processing node and/or 6400/4LPN 4 Loop processing node 2) Scope of approval does not include the operation of the network functionality. 3) Certified to EN 54-4 only. LPCB Ref. No. 201k/08
6400/PSU 8A
201k/09
January 2009
59
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 8.3 8.9 9.5 10 Fault signals from points Output to fault warning routing equipment Disablement of addressable point Test condition LPCB Ref. No.
P-C201
548j/02
P-C202
548j/03
P-C204
548j/04
P-C208
548j/05
P-C216
548j/06
60
January 2009
SECTION 3: PART
UK Sales: Fire Safety and Security Limited Tel: +44 (0)1734 783703 Fax: +44 (0)1734 775750
Certificate No: 126h to EN 54: Part 2 and 4: 1997 Certificated Products CS1140 Control and indicating equipment Comprising the following products: CC1140 Control and indicating equipment CT11 Operators console CI1140 Integrated central unit Incorporating as modular units: E3X100 Master module E3X102 Master Module E3X103 Master Module E3X120 Master card Cl1145 E3C010 Battery charging module E3C011 Battery charging module B2F020 Converter B2F040 Converter E3M140 Line module FD20 E3M070 Line module "Interactive" E3M071 Line module Interactive K3M140 Line card FD20 K3M071 Line card Interactive to E3X120 K3M080 Line card Collective B3Q460 Control console Algopilot "CT11" B3Q321 Fire department control panel (Swiss) E3G050 Contacts control unit E3G070 Universal control unit E3I020 RS232 unit K3I060 RS232 module E3L020 I/O control unit E3M080 Group line unit K3R071 Synoptic - Algo pilot K3R070 Synoptic - Algo pilot K3I050 LON/Synoptic converter E3M060 MS9i module E3G091 Remote TX i/face E3M110 AnalogPLUS module E3M111 Line module AnaloguPLUS K3M111 Line card AnalogPLUS B3R051 Parallel indicator panel (24 x 2 LED) E3G080 Control module Extinguishing B3Q440 Control console Extinguishing module E3G060 Control monitored module E3H020 C-Bus Gateway module E3I040 I-Bus/LON module B3Q560/B3Q600 Terminals China B3Q580 Text display terminal B3Q590 Text control terminal Nordic B3Q660 Operator console Standard Algopilot "CT11" B3Q661 Operator console Standard Algopilot "CT11" B3Q680 Control console Nordic Algopilot "CT11" LPCB Ref. No. 126h/01
January 2009
61
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products B3Q565 Operator control Asia Pacific Algopilot "CT11" K3N010 RAM - Extension K3I110 LON Input/Output Box E3M171 Line Module Ex Interactive K5L020 Multi-Sect. Extinguishing P.C.B K3G060 Relay Card to Synptic BUS E3G100 Emergency Operation Link E3G110 Emergency Link to E3G080 K3R072 Synoptical Driver M3C080 Horn Monitoring Module Notes: 1) The following options with requirements are approved with this equipment: 7.8 Outputs to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to Fire Protection Equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.4 Complete failure of power supply 9.5 Disablement of addressable points 10 Test condition 11 Standardised input/output interface 1) Compliance with clause 12.6.2 of EN 54-2:1997 requires LCD screen saving feature to be disabled for the alarm condition. Fire Detection Control Unit Incorporating: B3Q510 Control Panel K3X010 Master card collective K3M010 line extension card K3M020 line extension card B3R 080 parallel indicator card Approved with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 10 Test condition Fire Detection Control Unit Incorporating: B3Q580 Text Display Terminal B3Q590 Text Control Terminal B3R051 Parallel Indicator Unit B3R080 Parallel indicator card (32 LED) K3G050 Relay card K3G060 Relay p.c.b K3I050 LON Synoptic p.c.b K3I080 Serial LON ITF K3I090 PSA Interface K3I110 LON I/O Box K3L070 VdS Interface K3L100 LED driver card K3M010 Line extension card "Collector 4 line" K3M020 Line extension card "Collector 8 line" K3M030 Line extension card "Analogue Plus" K3R071 Synoptic-Driver K3R072 Synoptic-Driver K3X020 Master Board Analogue Plus K3X030 Master Module M3C080 Impedance translator M3P140 Monitoring Card 24V Z3S020 key switch nordic Z3S030 key switch KABA Z3l1020 Akku extension set. Approved with the following options from EN 54-2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.11 Delays to outputs 7.12 Coincidence detection LPCB Ref. No.
CS1110 AlgoControl
126h/02
CS1115 AlgoControl
126h/03
62
January 2009
SECTION 3: PART
Certificated Products 7.13 Alarm Counter 8.3 Fault signals from points 8.4 Total loss of power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Fire detection control unit Incorporating: B3Q580 Text Display Terminal B3Q590 Text Control Terminal B3R051 Parallel Indicator Unit B3R070 Parallel indicator card B3R080 Parallel indicator card K3G050 Relay card K3G060 Relay p.c.b K3I050 LON Synoptic p.c.b K3I080 Serial LON ITF K3I090 PSA Interface K3I110 LON I/O Box K3L070 VdS Interface K3L100 LED driver card K3M010 Line extension card K3M020 Line extension card K3M030 Line Card K3R071 Synoptic-Driver K3R072 Synoptic-Driver K3X020 Master Board Analogue Plus K3X030 Master Module M3C080 Impedance translator M3P140 Monitoring Card 24V Z3S020 key switch nordic Z3S030 key switch KABA Approved with the following options from EN 54-2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm Counter 8.3 Fault signals from points 8.4 Total loss of power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Control and indicating equipment Incorporating as modular units. FCM2002-A2 Control unit with, display, keyboard, coloured keys, LED indicator(FTO2002) FP2001-A1 70W Power supply and as optional modular units. FCM2001-A2 Control unit with, display, keyboard, coloured keys FCM2004-A1 PMI- & Mainboard FCM2005-A2 Empty Operating add-on module FCM2006-A2 Operating add-on module with 2 LED indicator unit FTO2002 and optional event printer FTO2001-A1 FTO2001-A1 Event printer FCI2003-A1 FDnet/SynoNET Loop extension FTO2002-A1 24 LED module FN2001-A1 SAFEDLINK Networking module (See Note 2) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module FCI2002-A1 Periphery board (2-Loop) FCM2003-C2 Operating unit (incl. FBA-Term.CH) FCM2003-N2 Operating unit (incl. EVAC-Term.NL) FTO2004-C1 PCB compl. FBA-Terminal (CH) FTO2007-N1 PCB compl. EVAC-module (NL) FHA2002-A1 Rear housing FCA20xx Relay module FCA20xx[DE] Shielded termination SV 24V-150W 150W Power supply REDUX Redundancy module Certified with the following options with requirements from EN 54-2: LPCB Ref. No.
FC330A AlgoControl
126h/03
FC2020
126h/04
January 2009
63
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardised input/output interface Notes: 1) Scope of approval does not include the operation of the network functionality. Control and indicating equipment Incorporating as modular units. FCM2002-A2 Control unit with, display, keyboard, coloured keys, LED indicator (FTO2002) SV 24V-150W 150W Power supply and as optional modular units. FCM2001-A2 Control unit with, display, keyboard, coloured keys FCM2004-A1 PMI- & Mainboard FCM2005-A2 Empty Operating add-on module FCM2006-A2 Operating add-on module with 2 LED indicator unit FTO2002 and optional event printer FTO2001-A1 FT02001-A1 Event printer FCM2007-A2 Operating add-on module with 4 LED indicator unit FTO2002 FCI2003-A1 FDnet/SynoNET Loop extension FTO2002-A1 24 LED module FN2001-A1 SAFEDLINK Networking module (See Note 2) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2004-A1Periphery board (4-Loop) FCI2001-D1Fire brigade periphery module FCM2003-C2 Operating unit (incl. FBA-Term.CH) FCM2003-N2 Operating unit (incl. EVAC-Term.NL) FTO2004-C1 PCB compl. FBA-Terminal (CH) FTO2007-N1 PCB compl. EVAC-module (NL) FHA2003-A1 Rear housing FCA20xx Relay module FCA20xx[DE] Shielded termination REDUX Redundancy module Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardised input/output interface Notes: 1) Scope of approval does not include the operation of the network functionality. Fire detection terminal Incorporating as modular units. FCM2002-A2 Control unit with, display, keyboard, coloured keys, LED indicator (FTO2002) FP2001-A1 70W Power supply and as optional modular units. FCM2001-A2 Control unit with, display, keyboard, coloured keys FCM2004-A1 PMI & mainboard FTI2001-A1 Fire detection terminal board FN2001-A1 SAFEDLINK Networking module (See Note 2) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FTO2001-A1 Event printer FTO2002-A1 24 LED module FCM2003-C2 Operating unit (incl. FBA-Term.CH) FCM2003-N2 Operating unit (incl. EVAC-Term.NL) LPCB Ref. No.
FC2040
126h/05
FT2040
126h/06
64
January 2009
SECTION 3: PART
Certificated Products FTO2004-C1 PCB compl. FBA-Terminal (CH) FTO2007-N1 PCB compl. EVAC-module (NL) FHA2001-A1 Rear housing REDUX Redundancy module 1) Scope of approval does not include the operation of the network functionality. LPCB Ref. No.
January 2009
65
PART 3: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products IOB800 FB800 Input/Output Expansion Board Fuse Board LPCB Ref. No.
Certified with the following options with requirements from EN 54-2: 1997 Output to fire alarm devices Output to fire alarm routing equipment Output to fire protection equipment Delays to outputs Co-incidence detection Alarm counter 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Incorporating the following as modular units, is approved for use with the MX4000 Control and indicating equipment: OCM800 (Operator Control Module) ODM800 (Operator Display Module) PSM800 (Power Supply Module) and as optional modular units: ANN840 (40 + 40 LED Annunciator) ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) 7.8 7.9 7.10 7.11 7.12 7.13
763b/R01
Certificate No: 763-cl-(1) to EN 54-2: 1997 and EN54-4: 1997 Product Name Control and Indicating Equipment Repeater Panel Model No MX 4000 Alternative MX 4000 Labelled Thorn Security Ltd t/a Tyco Safety Products Thorn Security Ltd t/a Tyco Safety Products Distributor Ref No 763-(cl-1) LPCB Ref. No. 763b/01
MXR Repeater
MXR Repeater
763b-(cl-1)
763b/R01
66
January 2009
COMMERCIAL DETECTORS
There are many types of detectors on the market designed to work on different principles and fire parameters (e.g. smoke, flame radiation, convective heat etc). The selection of a detector for a particular area or application should be based on a number of factors including the following: The nature of the fire hazard The speed of response required The need to minimize false alarms
There are other factors to be taken into account such as architecture of the building, ease of maintenance and cost. Guidance on the selection of appropriate types of detectors should be sought from the applicable installation rule or code of practice (e.g. BS 5839-1). Where a particular type of detector is not covered by the installation rule or code of practice then guidance should be sought from the manufacturers literature. In any case, account should be given to the notes or limitations given with the listed detector in this section. This section lists fire detectors approved for use in fire detection and fire alarm systems in buildings. The initial approval and continued approval processes for detectors are outlined in scheme document SD021. The list includes detectors certified to recognised standards or to special test schedules which are developed by LPCB for detector types where suitable standards are not available or were not available at the time of the evaluation. Products listed in this section have been approved to: EN 54-5:2000 Heat detectors - point detectors EN 54-5:2000 + A1: 2002 Heat detectors - point detectors EN 54-7:2000 Smoke detectors - point detectors using scattered light, transmitted light or ionisation EN 54-7:2000 +A1: 2002 and A2: 2006 Smoke detectors - point detectors using scattered light, transmitted light or ionisation EN 54-10:2002 Flame detectors - point detectors EN 54-10:2002 + A1: 2005 Flame detectors - point detectors EN 54-12:2002 Smoke detectors - line detectors using an optical light beam EN 54-20:2006 Aspirating smoke detectors ISO7240-5:2003 Point -type heat detectors ISO7240-6:2004 Carbon monoxide fire detectors using electro-chemical cells ISO7240-7:2003 Point-type smoke detectors using scattered light, transmitted light or ionization ISO7240-12:2005 Line type smoke detectors using transmitting light beam ISO7240-15:2004 Multisensor fire detectors ISO 7240-6:2008 Carbon monoxide fire detectors using electro-chemical cells and heat sensors. CEA 4021:1999 Requirements and test methods for multisensor detectors, which respond to smoke and heat, and smoke detectors with more than one smoke sensor CEA 4021:2003 Requirements and test methods for multisensor detectors, which respond to smoke and heat, and smoke detectors with more than one smoke sensor CEA 4022:1999 Requirements and test methods for aspirating smoke detectors LPS 1265-1.1:2005 Requirements and Testing Procedures for the LPCB Approval and Listing of Carbon Monoxide Fire Detectors Using Electrochemical Cells LPS 1274-1.0:2005 Testing Procedures for the LPCB Approval and Listing of Carbon Monoxide / Heat Multisensor Fire Detectors Using Electrochemical Cells LPS 1279:2006 Testing Procedures for the LPCB Approval and Listing of Point Multisensor Fire Detectors using Optical or Ionization Smoke Sensors and Electrochemical Cell CO Sensors and, optionally, Heat Sensors
Approval can also be obtained for other detection principles not detailed above. In such circumstances, LPCB can develop test criteria to evaluate products, which in time may be used for the development of standards. Audit:
January 2009
67
68
January 2009
COMMERCIAL DETECTORS
Multi-criteria Detectors
Certificated Products AE/C5-OPT Conventional 2 wire photoelectric smoke and heat detector with remote LED output (P/N854001 base) LPCB Ref. No. 512b/02
Stratos HSSD 2
404b/02
Stratos HSSD 2
404b/03
Stratos HSSD 2
404b/04
January 2009
69
Certificate No: 404c to EN54-20: 2006 Certificated Products Stratos Micra 25 High sensitivity aspirating smoke detector Notes: 1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. 3) The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.31%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating smoke detector. Notes: 1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. 3) The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. LPCB Ref. No. 404c/01
404c/02
Smoke Detectors
Certificated Products EA318-2L Conventional 2 wire photoelectric smoke detector with remote LED output (E300-Base) LPCB Ref. No. 512a/02
Heat Detectors
Certificated Products EA323-2L/A2R Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (E300-Base) LPCB Ref. No. 512d/04
70
January 2009
COMMERCIAL DETECTORS
Sales Enquiries Spain, Apollo Espana Tel: +34 627 988 061 Fax: +34 949 335 289 E-mail: apollo.espana@apollo-fire.com
Sales Enquiries China, Apollo Fire Detectors Limited, Shanghai representative office Tel: +86 21 5237 0922 Fax: +86 21 5237 0920 E-mail: tony.ye@apollo-fire.com
Certificate No: 010ab to EN 54-5: 2000 + A1: 2002 Certificate No: 010p to EN 54: Part 5: 2000 Certificate No: 010r to EN 54: Part 5: 2000
January 2009
71
XPA-HT-11171-APO
010ab/02
55000-120 Series 65
010p/04
55000-121 Series 65
010p/05
55000-122 Series 65
010p/06
55000-125 Series 65
010p/07
55000-126 Series 65
010p/08
55000-127 Series 65
010p/09
55000-130 Series 65
010p/10
55000-131 Series 65
010p/11
55000-132 Series 65
010p/12
55000-135 Series 65
010p/13
55000-136 Series 65
010p/14
55000-137 Series 65
010p/15
55000-400 XP95
010p/20
55000-401 XP95
010p/21
72
January 2009
COMMERCIAL DETECTORS
LPCB Ref. No.
55000-420 XP95
010p/22
010p/23 010p/03
59000-400 XPlorer 59000-410 XPlorer Orbis Class A1R Orbis Class A1S Orbis Class A2S Orbis Class BR Orbis Class BS Orbis Class CR Orbis Class CS Orbis IS Class A1R Orbis IS Class A1S Orbis IS Class A2S Orbis IS Class BR Orbis IS Class BS Orbis IS Class CR Orbis IS Class CS
010p/01 010p/02 010r/01 010r/07 010r/02 010r/03 010r/04 010r/05 010r/06 010r/08 010r/14 010r/09 010r/10 010r/11 010r/12 010r/13
Bases: 45681-200 Series 60 mounting base 45681-200 Series 60/65 Mounting Base 45681-201 Series 60 diode mounting base 45681-201 Series 60/65 Diode Mounting Base 45681-207 Series 60 intrinsically safe mounting base 45681-209 XP95/Discovery standard deep mounting base 45681-210 XP95 mounting base 45681-215 XP95 intrinsically safe mounting base 45681-245 Series 65 Relay mounting base 45681-246 Series 65 Auxiliary relay mounting base 45681-247 Series 65 EOL 12 Volt mounting base 45681-248 Series 65 EOL 24 Volt mounting base 45681-500 XPlorer standard mounting base 45681-501 XPlorer remote LED mounting base TimeSaver bases with Apollo Approval Reference* OB TimeSaver LX bases with Apollo Approval Reference* OL
January 2009
73
Certificate No: 010ac to EN 54-7: 2000 + A1: 2002 Certificate No: 010q to EN 54: Part 7: 2000 Certificate No: 010s to EN 54: Part 7: 2000
55000-215 Series 65
010q/04
55000-219 Series 65
010q/08
55000-220 Series 65
010q/09
55000-315 Series 65
010q/10
55000-520 XP95
010q/17
74
January 2009
COMMERCIAL DETECTORS
55000-600 XP95
010q/18
55000-620 XP95
010q/19
010q/23 010q/21
58000-500 Discovery
010q/02
58000-600 Discovery
010q/03
Bases: 45681-200 Series 60 mounting base 45681-200 Series 60/65 Mounting Base 45681-201 Series 60 diode mounting base 45681-201 Series 60/65 Diode Mounting Base 45681-207 Series 60 intrinsically safe mounting base 45681-209 XP95/Discovery standard deep mounting base 45681-210 XP95 mounting base 45681-215 XP95 intrinsically safe mounting base 45681-245 Series 65 Relay mounting base 45681-246 Series 65 Auxiliary mounting base 45681-247 Series 65 EOL 12 Volt mounting base 45681-248 Series 65 EOL 24 Volt mounting base 45681-500 XPlorer standard mounting base 45681-501 XPlorer remote LED mounting base TimeSaver bases with Apollo Approval Reference* OB TimeSaver LX bases with Apollo Approval Reference* OL TimeSaver diode bases with Apollo Approval Reference* OD TimeSaver relay bases with Apollo Approval Reference* OR TimeSaver LX diode bases with Apollo Approval Reference* DX TimeSaver IS bases with Apollo Approval Reference* OB (+ATEX marking) ORB-BA-50008 Orbis intrinsically safe adapter base (to be used in conjunction with the following bases only: 45681-207) ORB-BA-10008-APO Orbis adaptor base (to be used in conjunction with the following bases only: 45681-200 & 45681-201) XPA-WB-10022-APO Radio link mounting base**
January 2009
75
010ad to EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 010h to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002 & CEA 4021:2003 010m to CEA 4021: 1999-06(en) 010t to EN 54-7: 2000 & CEA 4021: 1999-06
Multi-criteria Detectors
Certificated Products XPA-OH-13032-APO Xpander addressable radio linked photoelectric multisensor smoke detector (XPA-WB10022-APO mounting base) Notes: 1) The complete radio base/detector combination is available as Apollo Part No.: XPACB-13032-APO. 2) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells. 3) The radio link functionality is not included within the scope of approval. Intrinsically safe multisensor detectors with Apollo Approval Reference* 50008 (Approved for use with base styles OB (+ATEX marking) and ORB-MB-50008-APO adapter base) 1 Analogue addressable multisensor detector (45681-209 and 45681-210 mounting base) Certificated with Apollo, Discovery, XP95 and S90 digital communication protocols that have been configured for the Discovery multisensor detector in accordance with manufacturer's instructions. Analogue addressable multisensor detector (45681-209 and 45681-210 mounting base) Note: Certificated at the following settings. Mode 1 - High sensitivity smoke detector with standard heat enhancement. Mode 2 - Smoke detection only. Mode 3 - Medium sensitivity smoke detector with standard heat enhancement. Mode 4 - Low sensitivity smoke detector with high heat enhancement. Mode 5 - Class A1 heat detector. Also Certificated in conventional alarm modes 1, 2, 3, 4 and 5. Certificated with Discovery XP95 and S90 digital communication protocols that have been configured for the Discovery multisensor detector in accordance with manufacturer's instructions. Multisensor smoke detectors with Apollo Approval Reference* 00008 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base) LPCB Ref. No. 010ad/01
010t/02 010m/01
58000-700 Discovery
010h/01
Orbis
010t/01
Bases: 45681-209 XP95/Discovery standard deep mounting base 45681-210 XP95 mounting base TimeSaver bases with Apollo Approval Reference* OB TimeSaver LX bases with Apollo Approval Reference* OL TimeSaver diode bases with Apollo Approval Reference* OD TimeSaver relay bases with Apollo Approval Reference* OR TimeSaver LX diode bases with Apollo Approval Reference* DX TimeSaver IS bases with Apollo Approval Reference* OB (+ATEX marking) ORB-BA-50008 Orbis intrinsically safe adapter base (to be used in conjunction with the following bases only: 45681-207) ORB-BA-10008-APO Orbis adaptor base (to be used in conjunction with the following bases only: 45681-200 & 45681-201) XPA-WB-10022-APO Radio link mounting base** * The Apollo Approval Reference Number identifies a group of detectors that all have the same physical construction, but have features enabled or disabled via their software, and/or regional marking variations. **Base manufactured by EMS
76
January 2009
COMMERCIAL DETECTORS
Argus-Spectrum
65 Serdobolskaya St, St. Petersburg 197342, Russia Tel: +7 812 7037500 Fax: +7 812 7037501 E-mail: mail@argus-spectr.ru Website: www.argus-spectr.ru
Certificate No: 603a to EN 54-7:2000
Smoke Detector
Certificated Products AURORA S100 Bases: BS100 Standard base BSD100 Schottky Diode base Conventional photoelectric smoke detector (BS100 and BSD100 mounting bases) LPCB Ref. No. 603a/01
Bardic by Honeywell
140 Waterside Road, Hamilton Industrial Estate, Leicester LE5 1TN UK Tel: +44 (0) 116 246 2212 Fax: +44 (0) 116 246 2210 Website: www.bardic.co.uk
Certificate No: 199n to EN 54-5: 2000
Heat Detectors
Certificated Products ZF03 class A2S ZF04 class BS ZF05 class A1R Conventional fixed temperature heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) Conventional fixed temperature heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) Conventional rate of rise heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) LPCB Ref. No. 199n/10 199n/11 199n/12
Bases: 2020B Standard base 2020DB Deep base 2020BSD Standard base with schottky diode 2020DBSD Deep base with schottky diode
January 2009
77
Bases: 2020B Standard base 2020DB Deep base 2020BSD Standard base with schottky diode 2020DBSD Deep base with schottky diode
Certificate No: 199p to EN 54-5: 2000, EN 54-7: 2000 & CEA 4021 1999
Multi-criteria Detectors
Certificated Products ZF02 Conventional photo thermal detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) LPCB Ref. No. 199p/04
Bases: 2020B Standard base 2020DB Deep base 2020BSD Standard base with schottky diode 2020DBSD Deep base with schottky diode
78
January 2009
COMMERCIAL DETECTORS
Bases: B501 Analogue sensor base B501DG Analogue sensor deep base B524IEFT Analogue sensor isolator base
Certificate No: 199p to EN 54-5: 2000, EN 54-7: 2000 & CEA 4021: 1999
Multi-criteria Detectors
Certificated Products Resonance Combined Analogue addressable optical/thermal smoke & heat detector (B501, B501DG and B5241EFT bases) Note: Meets the requirements of EN 54-5: 2001 at class A1R & EN 54-7: 2000 at sensitivity settings 1 to 5 LPCB Ref. No. 199p/02
Bases: B501Analogue sensor base B501DG Analogue sensor deep base B524IEFT Analogue sensor isolator base
Bases: B501 Analogue sensor base B501DG Analogue sensor deep base B524IEFT Analogue sensor isolator base
Cofem S.A.
Ctra. Molins de Rei a Rubi, Km 8.4, 08191 Rubi, Barcelona, Spain Tel: +34 935862690 Fax: +34 936999261 E-mail: cofem@cofem.com Website: www.cofem.com
Certificate No: 693a to EN 54-7: 2000
January 2009
79
Multi-criteria Detectors
Certificated Products CPT341 CPTB341 Conventional opto/heat multisensor and Class A2S heat detector (CDB300 base) Conventional opto/heat multisensor and Class A2S heat detector (CDB300 base) LPCB Ref. No. 685g/01 685g/01
Bases: CDB300 Standard conventional mounting base CDBB300 Standard conventional mounting base
Bases: CDB300 Standard conventional mounting base. CDBB300 Standard conventional mounting base.
Certificate No: 685h to EN 54-7:2000 + A1:2002 + A2:2006 Certificate No: 685b to EN 54-7: 2000 Certificate No: 685d to EN 54-7: 2000
80
January 2009
COMMERCIAL DETECTORS
Bases: FXN520 standard conventional mounting base (JSB version) CDB300 standard conventional mounting base (CFS version) CDBB300 standard conventional mounting base (CFS version) COPC800 standard conventional mounting base (CFS version) MAB800 standard analogue addressable mounting base FXN720 standard analogue addressable mounting base (JSB version) COPA800 standard analogue addressable mounting base (CFS version) CAB300 standard analogue addressable mounting base (CFS version) CABB300 standard analogue addressable mounting base (CFS version) MDB800 standard conventional mounting base MDB800 Standard conventional mounting base (Menvier version) FXN520 Standard conventional mounting base (JSB version)
Certificate No: 685c to EN 54-5: 2000 Certificate No: 685e to EN 54-5: 2000, EN 54-7: 2000, GEI 1-052, Draft 2.0, 11/06/97 and CEA 4021: 1999 Certificate No: 685a to EN 54-5: 2000
January 2009
81
Certificate No: 685g to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002 + A2:2006, CEA 4021:2003
Multi-Criteria Dectectors
Certificated Products FXN632 MPT951 Conventional opto/heat multisensor and Class A2S heat detector (JSB version) (FXN520 base) Conventional opto/heat multisensor and Class A2S heat detector (Menvier version) (MDB800 base) LPCB Ref. No. 685g/01 685g/01
Bases: MDB800 Standard conventional mounting base (Menvier version) FXN520 Standard conventional mounting base (JSB version)
Detectomat GmbH
An Der Strusbek 5, D-22926 Ahrensburg, Hamburg, Germany Tel: +49 4102 2114 636 Fax: +49 4102 2114 670 E-mail: approval@detectomat.com
Certificate No: 632a to EN 54-7: 2000
82
January 2009
COMMERCIAL DETECTORS
Certificate No: 632c to EN 54-5: 2000, EN 54-7: 2000, CEA 4021: 2003 & CEA GEI 1-052: Draft 2.0, 11.06.97 Certificate No: 632d to EN 54-5: 2000, EN 54-7: 2000 & CEA 4021: 2003
Multi-criteria Detectors
Certificated Products PL 3300 OT PL 3200 OT Analogue addressable multisensor detector with short circuit isolator (30301 base) Note: Meets the requirements of EN 54-5: 2000 at Class A1 and EN 54-7: 2000 at standard sensitivity setting Analogue addressable multisensor detector (30301 base) Note: Meets the requirements of EN 54-5: 2000 at Class A1 and EN 54-7: 2000 at standard sensitivity setting LPCB Ref. No. 632c/01 632d/01
January 2009
83
Multi-criteria Detectors
Certificated Products FADY-MUS Analogue addressable multisensor detector (FA95-ACB mounting base) Notes: 1) Certificated at the following settings: Mode 1 - High sensitivity smoke detector with standard heat enhancement Mode 2 - Smoke detection only Mode 3 - Medium sensitivity smoke detector with standard heat enhancement Mode 4 - Low sensitivity smoke detector with high heat enhancement Mode 5 - Class A1 heat detector Also approved in conventional alarm modes 1, 2, 3, 4 and 5 2) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols configured for the Discovery heat detector in accordance with manufacturers instructions. LPCB Ref. No. 010h/01
Multi-criteria Detectors
Certificated Products FX-0315-2 FX-0315-3 FX-0315-4 Bases: AHMB-031 mounting base (2 - wire) Optical smoke and Class A2 heat detector (AHMB-31 Base) (3 - wire) Optical smoke and Class A2 detector (AHMB-31 Base) (4 - wire) Optical smoke and Class A2 heat detector (AHMB-31 Base) LPCB Ref. No. 506b/01 506b/02 506b/03
84
January 2009
COMMERCIAL DETECTORS
Smoke Detectors
Certificated Products XP-174-001 Fire-Cell addressable radio linked photoelectric multisensor smoke detector (XP-170-001 mounting base) Notes: 1) The complete radio base/detector combination is available as EMS Part No.: XP-130001 2) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells 3) The radio link functionality is not included within the scope of approval Fire-Cell addressable radio linked photoelectric smoke detector (XP-170-001 Radio link mounting base) Notes: 1) The complete radio base/detector combination is available as EMS Part No.: XP-100001 2) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells 3) The radio link functionality is not included within the scope of approval LPCB Ref. No. 786c/01
XP-177-001
786e/01
Heat Detectors
Certificated Products XP-175-001 Fire-Cell addressable radio linked Class A1R heat detector (XP-170-001 Radio link mounting base) Notes: 1) Meets the requirements of EN 54-5 for Class A1R 2) The complete radio base/detector combination is available as EMS Part No.: XP-120001 3. The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells 4) The radio link functionality of this device is not included within the scope of approval Fire-Cell addressable radio linked Class CS heat detector (XP-170-001 Radio link mounting base) LPCB Ref. No. 786d/01
XP-176-001
786d/02
January 2009
85
Smoke Detectors
Certificated Products EA318-2 EA318-2(LED) EA318-4-12 EA318-4-24 Conventional 2 wire photoelectric smoke detector (P/N852001 base) Conventional 2 wire photoelectric smoke detector with remote LED output (P/N854001 base) Conventional 4 wire photoelectric smoke detector (P/N854001 base) Conventional 4 wire photoelectric smoke detector (P/N854001 base) LPCB Ref. No. 512a/01 512a/02 512a/03 512a/04
Multi-criteria Detectors
Certificated Products EA318-2H EA318-2H-LED EA318-4H-12 EA318-4H-24 Conventional 2 wire photoelectric smoke and heat detector (P/N852001 base) Conventional 2 wire photoelectric smoke and heat detector with remote LED output (P/N854001 base) Conventional 4 wire photoelectric smoke and heat detector (P/N854001 base) Conventional 4 wire photoelectric smoke and heat detector (P/N854001 base) LPCB Ref. No. 512b/01 512b/02 512b/03 512b/04
86
January 2009
COMMERCIAL DETECTORS
January 2009
87
Heat Detectors
Certificated Products FX9103 FX9103I Conventional heat detector Class A1R (DZ-03 base) Intelligent Rate of Rise Heat Detector Class A1R (DZ-03 base) LPCB Ref. No. 548c/01 548c/02
Smoke Detectors
Certificated Products FX9102 FX9102I Conventional Photoelectric Smoke Detector (DZ-03 base) Intelligent Photoelectric Smoke Detector (DZ-03 base) LPCB Ref. No. 548d/01 548d/02
Beam Detectors
Certificated Products FX9105RI Intelligent optical beam detector Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 - 1.61 dB Level 2 - 2.31dB LPCB Ref. No. 548k/01
88
January 2009
COMMERCIAL DETECTORS
Certificate No: 092n to EN 54-7: 2000 Certificate No: 092s to CEA 4022: 1999-12
Bases: ZP7-SB1 standard base Z6-BS1 conventional surface base Z6-BS5 conventional diode base
Bases: ZP7-SB1 standard base Z6-BS1 conventional surface base Z6-BS5 conventional diode base
Certificate No: 092k to EN 54:Part 5: 2000, EN 54:Part 7: 2000 and CEA 4021: 2003
Multi-criteria Detectors
Certificated Products ZP732-2 Analogue addressable combined photoelectric smoke and class A1 heat detector (ZP7SB1 base) LPCB Ref. No. 092k/01
January 2009
89
GE Security Inc
5 North Main Street, Pittsfield, ME 04967, USA Tel: +1 207 487 3104 Fax: +1 207 487 5526 E-mail: leon.newsome@ge.com Website: www.gesecurity.com European Sales: Rudford Estate, Ford Aerodrome, Arundel, West Sussex BN18 0BE UK Tel: +44 (0)1903 711 440 Fax: +44 (0)1903 711 448 E-mail: info@estinternational.com
Certificate No: 262t to EN 54-7: 2000 Certificate No: 092n to EN 54-7: 2000 + A1:2002
SIGA-PSI
262t/02
Certificate No: 262u to EN 54-5: 2000 Certificate No: 092p to EN 54-5: 2000
90
January 2009
COMMERCIAL DETECTORS
Certificate No: 092k to EN 54-5: 2000, EN54-7: 2000, A1: 2002 and CEA 4021: 2003 Certificate No: 262s to EN 54-7: 2000 and CEA 4021: 1999
Multi-criteria Detectors
Certificated Products EA32E-2 Analogue addressable combined photoelectric smoke and Class A1 heat detector (ASBE-2 base) Note: Certificated at sensitivity profiles 1-4 for EN 54: Part 7 and sensitivity profiles 5 (A1) and 6 (A2) for EN 54: Part 5. Intelligent thermally enhanced photoelectric and ionisation smoke detector (SIGI-IBS, SIGI-SB, SIGI-SB4, SIGI-RB, and SIGI-RB4 bases) Note: Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. Intelligent thermally enhanced photoelectric smoke detector (SIGI-IBS, SIGI-SB, SIGI-SB4, SIGI-RB, and SIGI-RB4 bases) Note: Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. LPCB Ref. No. 092k/01
SIGA-IPHSI
262s/01
SIGA-PHSI
262s/02
Bases: SIGA-SB standard base SIGA-SB4 standard base and trim skirt SIGA-RB relay base SIGA-RB4 relay base and trim skirt SIGA-IBS Isolator base SIGA-IBS4 Isolator base and trim skirt SIGI-IBS Isolator base SIGA-SB Standard base SIGA -SB4 Standard base with trim skirt SIGA -RB Relay base SIGA -RB4 Relay base with trim skirt
Gent By Honeywell
140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN UK Tel: +44 (0)116 246 2000 Fax: +44 (0)116 246 2300 E-mail: gent_enquiry@gent.co.uk Website: www.gent.co.uk Middle East Sales Enquiries: E-mail: gent.export@honeywell.com
Certificate No: 400j to EN 54-7: 2000 Certificate No: 567a to BS 5445: Part 7: 1984 This certificate is to a withdrawn standard. Detectors conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. Certificate No: 042as to EN 54-7: 2000 + A1: 2002 and GEI 1 - 084
S4-770
042an/04
January 2009
91
S4-715
042as/01
O-803371 17830-01
400j/03 567a/01
17840-01
567a/02
Bases: 78200-01NM standard base 17800-01 standard base 17801-01 standard base with diode 17800-02 low profile base 17801-02 low profile base with diode 805590 vase for series 1Q8quad detectors 805591 base for series 1Q8quad detectors with relay output
Certificate No: 567b to BS 5445: Part 5: 1977 This certificate is to a withdrawn standard. Detectors conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. Certificate No: 042aj to EN 54-5: 2000 + A1: 2002 & CEA GEI 1 - 084 Certificate No: 042ak to EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1: 2002 & CEA GEI 1 - 084
S4-780
042ak/01
17850-01
567b/01
17860 -01
567b/02
92
January 2009
COMMERCIAL DETECTORS
Bases: 34700 standard base 17800-01 standard base 17801-01 standard base with diode 17800-02 low profile base 17801-02 low profile base with diode S4-700 standard base S4-FLUSH semi-flush fixing kit
Certificate No: 567d to BS 5445: Part 5: 1977 and BS 5445: Part 7: 1984 This certificate is to a withdrawn standard. Detectors conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. Certificate No: 042am to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003-07 & CEA GEI 1 - 084 Certificate No: 042an to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2000, EN 54-3: 2001 + A1:2002, CEA 4021: 2003-07 & CEA GEI 1 - 084
Multi-criteria Detectors
Certificated Products S4-711 S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Note: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector with strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat 2) The strobe function is not included within the scope of this approval S-Quad analogue addressable dual optical smoke, Class P heat and carbon monoxide multisensor detector (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 5 at the following settings: State 9 - Class A1 heat 3) Carbon monoxide detection is not included within the scope of this approval S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector with speech and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 3) Speech and strobe not included in scope of approval S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector LPCB Ref. No. 042am/01
S4-711-ST
042am/02
S4-911
042am/03
S4-711-ST-VO
042an/01
S4-771
042an/02
January 2009
93
Bases: 34700 standard base S4-700 standard base S4-FLUSH semi-flush fixing kit
Beam Detectors
Certificated Products I-9105R Intelligent Reflective Beam Detector Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 - 1.61 dB Level 2 - 2.31 dB LPCB Ref. No. 548k/01
94
January 2009
COMMERCIAL DETECTORS
Smoke Detectors
Certificated Products C-9102 I-9102 Bases: DZ-03 Standard detector base Conventional Photoelectric Smoke Detector (DZ-03 base) Intelligent Photoelectric Smoke Detector (DZ-03 base) LPCB Ref. No. 548d/01 548d/02
Bases: 80-050 FE CB Common mounting base 80-052 FE DB Diode mounting base 80-054 FE RB Relay mounting base 80-080 FEA RB Addressable relay mounting base 80-090 FE IB Negative switching isolating base
Bases: 80-050 FE CB Common mounting base 80-052 FE DB Diode mounting base 80-054 FE RB Relay mounting base 80-080 FEA RB Addressable relay mounting base 80-090 FE IB Negative switching isolating base
January 2009
95
Heat Detectors
Certificated Products GS104C GS104I Conventional heat detector Class A1R (DZ-03 base) Intelligent rate of rise heat detector Class A1R (DZ-03 base) LPCB Ref. No. 548c/01 548c/02
Smoke Detectors
Certificated Products GS102C GS102I Conventional photoelectric smoke detector (DZ-03 base) Intelligent photoelectric smoke detector (DZ-03 base) LPCB Ref. No. 548d/01 548d/02
Beam Detectors
Certificated Products GS105RI Intelligent optical beam detector Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 - 1.61 dB Level 2 - 2.31dB LPCB Ref. No. 548k/01
96
January 2009
COMMERCIAL DETECTORS
Gulf Security Technology Co. Ltd (Manufacturing Division of Global System Technology PLC)
No. 80 Changjiang East Road, Economic & Technological Development Zone, Qinhuangdao, Hebei Province 066004, Peoples Republic of China Tel: +86 0335 8502528 Fax: +86 0335 8508942 E-mail: gst@gst.com.cn Website: www.gst.com.cn Sales Enquiries: Tel: +852 28778566 Fax: +852 25118699 Tel: +86 (10)64392919 Fax: +86 (10)64391767
Beam Detectors
Certificated Products JTY-HM-GST102 Intelligent optical beam detector Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 - 1.61 dB Level 2 - 2.31 dB LPCB Ref. No. 548k/01
HDR
Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA UK Tel: +44 (0)1634 260133 Fax: +44 (0)1634 260132 E-mail: info@hochikieurope.com Website: www.hochikieurope.com
Certificate No: 117f to EN54-7: 2000 + A1: 2002 EN54-5: 2000 + A1: 2002 CEA 4021: 1999
January 2009
97
Bases: 1226150 Standard base 1426010 Standard base YCA-RL/3H2M Addressable base YBN-R/6SK Schottky diode base
Beam Detectors
Certificated Products 1213060 1213080 Optical Beam Smoke Detector Note: Certified at a sensitivity setting of 30% obscuration Conventional 2 wire optical beam smoke detector Notes: 1) Approved at sensitivity setting 25% and 50%. 2) Approved for use with 1213080 2WI interface kit. LPCB Ref. No. 117j/01 117j/03
Bases: 1226110 Short circuit isolating base 1226150 Standard base 1426010 Standard base YBN-R/6SK Schottky Diode base
98
January 2009
COMMERCIAL DETECTORS
Hiltron srl
Via Caserta al Bravo, 218 Napoli 80144, Italy Tel: +39 081 7050912 Fax: +39 081 7050125 E-mail: v.demaggio@hiltron.it Website: www.hiltron.it
Certificate No: 512a to EN 54-7: 2000
Certificate No: 512b to EN 54-5: 2000, EN 54-7: 2000 & CEA 4021: 1999
Multi-criteria Detectors
Certificated Products FRFT318 FRFT318R Conventional 2 wire photoelectric smoke and heat detector with remote LED output (P/N854001 base) Conventional 4 wire photoelectric smoke and heat detector (P/N854001 base) LPCB Ref. No. 512b/02 512b/03
January 2009
99
Manufacturing at: Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, Japan Tel: +81 3 3444 4111 Fax: +81 3 3444 4167 E-mail: overseas@hochiki.co.jp Website: www.hochiki.co.jp
Hochiki Europe (UK) Limited Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA UK Tel: +44 (01634 260131 Fax: +44 (0)1634 260132 E-mail: sales@hochikieurope.com Website: www.hochikieurope.com
Hochiki America Corporation 7051 Village Drive, Buena Park, California 90621, USA Tel: +1 714 522 2246 Fax: +1 714 522 2268 E-mail: sales@hochiki.com Website: www.hochiki.com
Certificate No: 117h to EN 54-7: 2000 Certificate No: 164g to EN 54-7: 2000 Certificate No: 358c to EN 54-7: 2000
LPCB Ref. No. 117h/01 164g/01 164g/01 164g/02 164g/03 164g/04 164g/05 358c/01 358c/02
100
January 2009
COMMERCIAL DETECTORS
ACB-E
117g/09
ACB-EW
117g/10
DCC-1EL DFG-60BLJ
117g/11 117g/12
Certificate No: 117f to prEN 54: Part 7 Draft A3 (1/4/97), prEN 54: Part 5 Draft F1 (21/7/97) and CEA GEI 1-049 (11/2/97)
Multi-criteria Detectors
Approved Products ACA-E(HFP) ACA-E/ASX Analogue addressable multisensor (YBN-R/3(HFP) base) Meets EN 54-5 class A1 and B and EN 54-7 at 3.0%/m sensitivity setting in normal and low power mode. 1 Analogue addressable multisensor (YBN-R/3 base) Note: Meets EN 54: Part 5 class A1 and B and EN 54: Part 7 at 3.0%/m sensitivity setting in normal and low power mode. LPCB Ref. No. 117f/01 117f/01
Bases: 1 YBN-R/3 base YBN-R/2NA base 1 YBO-R/SCI isolator base 1 YBN-R/4IS intrinsically safe mounting base YCA-RL/3H2 addressable base YCA-RL/5H2 master addressable base AMU-B2 addressable base AMU-MB master addressable base YBC-RL/4H5 base YBF-RL/3J slave base 1 YBF-RL/4H5 base 1 YBK-RL/4H1A base 1 YBK-RL/4H2 base YCA-RL/3H2M addressable base YBN-R/6SK Schottky diode base YBN-R/6 Standard base
January 2009
101
Bases manufactured buy Hochiki Europe. All other bases manufactured by Hochiki Corporation. denotes detector/base combination is approved in low power mode also.
Certificate No: 164e to BS 5839: Part 5 Certificate No: 164k to EN 54-12: 2002 Certificate No: 117j to EN 54-12: 2002
Beam Detectors
Certificated Products SRA-ET SRA-ET (HFP) SPC-E SPC-ET Optical Beam Smoke Detector Note: Certified at a sensitivity setting of 30% obscuration Optical Beam Smoke Detector Certified at a sensitivity setting of 30% obscuration. Conventional 4 wire optical beam smoke detector Notes: 1) Approved at sensitivity settings 25% and 50%. Conventional 2 wire optical beam smoke detector Notes: 1) Approved at sensitivity setting 25% and 50%. 2) Approved for use with SPC-ET2WI interface kit. Conventional 2 wire optical bem smoke detector. 1) Approved at sensitivity setting 25% and 50% 2) Approved for use with SPC-ET2WI interface kit Optical beam smoke detector Note: 1) Certificated at a sensitivity setting of 25% and when installed as option 2 as specified in DS0203 issue 1.2. Optical beam smoke detector Note: 1) Certificated at sensitivity setting of 25% and with SPB-ET2WI interface kit. Conventional optical beam smoke detector Note: 1) Approved at sensitivity setting 50%. Conventional optical beam smoke detector Notes: 1) Approved at sensitivity setting 50%. 2) Approved for use with SPB-ET2WI interface kit. LPCB Ref. No. 117j/01 117j/01 117j/02 117j/03
SPC-ET(HFP) SPB-E
117j/03 164e/01
Flame Detectors
Certificated Products IFD-E IFD-E(IS) IFD-E(EXD) Conventional IR Flame detector Note: Meets EN 54-10: 2002 at Class 1 only 3 Conventional IR Intrinsically Safe Flame Detector Note: Meets EN 54-10: 2002 at Class 1 only 3 Conventional IR (Exd) Flameproof Flame Detector Note: Meets EN 54-10: 2002 at Class 1 only
3
102
January 2009
COMMERCIAL DETECTORS
Multi-criteria Detectors
Certificated Products TC840ME Analogue optical/thermal smoke & heat detector (14506414-007 base) Notes: 1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1 to 5 2) Meets the requirements of EN 54-5:2000 at Class A1R LPCB Ref. No. 550b/03
Multi-criteria Detectors
Certificate No: 199p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1 2002 & CEA 4021: 2003
January 2009
103
TC850E1009
199t/01
Beam Detectors
Certificate No: 199p to EN 54-7: 2000, EN 54-5: 2000 & CEA 4021: 1999 Certificate No: 262s to EN 54-7: 2000
Multi-criteria Detectors
Certificated Products TC840ME Analogue addressable optical/thermal smoke & heat detector (B501, B501DG & B524IEFT bases) Note: Meets the requirements of EN54-5: 2000 at class A1R and EN54-7: 2000 at sensitivity settings 1 to 5 Intelligent thermally enhanced photoelectric smoke detector (SIGI-IBS, SIGA-SB, SIGASB4, SIGA-RB and SIGA-RB4 bases) Note: Meets the requirements of EN54-7-:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft and 3.5%/ft. Intelligent thermally enhanced photoelectric smoke detector SIGA-SB, SIGA-SB4, SIGARB and SIGA-RB4 bases) Note: Meets the requirements of EN 54-7: 2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, and 3/5%/ft. LPCB Ref. No. 199p/02
XLS-IPHSI
262s/01
XLS-PHSI
262s/02
Isolator base Standard base Standard base with trim skirt Relay base Relay base analogue detector base analogue deep base analgoue short circuit isolator base
104
January 2009
COMMERCIAL DETECTORS
Certificate No: 199n to EN 54-5: 2000 Certificate No: 262u to EN 54-5: 2000
Bases: SIGI-IBS Isolator base SIGA-SB Standard base SIGA-SB4 Standard base with trim skirt SIGA-RB Relay base B501 analogue detector base B501DG analogue deep base B524IEFT analogue short circuit isolator base
Certificate No: 199m to EN 54-7:2000 Certificate No: 262t to EN 54-7: 2000 Certificate No: 118h to EN 54-7: 2000
XLS-PSI
262t/02
Bases: B501 analogue detector base B501DG analogue deep base B524IEFT analogue short circuit isolator base B524IEFT-1 analogue short circuit isolator base SIGI-IBS Isolator base SIGA-SB Standard Base SIGA-SB4 Standard base with trim skirt SIGA-RB Relay base SIGA-RB4 Relay base with trim skirt
January 2009
105
Multi-criteria Detectors
Certificated Products AH-0315-2 AH-0315-3 AH-0315-4 Bases: AHMB-031 mounting base (2 wire) Optical smoke and class A2 heat detector (AHMB-031 Base) (3 wire) Optical smoke and class A2 heat detector (AHMB-031 Base) (4 wire) Optical smoke and class A2 heat detector (AHMB-031 Base) LPCB Ref. No. 506b/01 506b/02 506b/03
ICAM Limited
Spring Gardens, London Road, Washington, West Sussex RH20 3BS UK Tel: +44 (0)1903 892222 Fax: +44 (0)1903 892277 Website: www.icam.ltd.uk
Certificate No: 451a to CEA 4022: 1999-1
Smoke Detectors
Certificated Products FireTracer 1 Aspirating smoke detector with display LPCB Ref. No. 451a/01
106
January 2009
COMMERCIAL DETECTORS
FireTracer 1
451a/01
FireTracer 4
451a/02
FireTracer 4
451a/02
FireTracer 6
451a/03
January 2009
107
FireTracer 8
451a/04
FireTracer 8
451a/04
FireTracer 15
451a/05
FireTracer 15
451a/05
108
January 2009
COMMERCIAL DETECTORS
Johnson Controls
Johnson Controls Holding Italia Srl., Via Manzoni,, 44, 20095 Cusano, Milan, Italy Tel: +39 (0)2 280421 Fax: +44 (0)1283 220690 E-mail: sergio.bellano@jci.com Website: www.johnsoncontrols.com
Certificate No: 199t to LPS1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003
Multi-Criteria Detectors
Certificated Products 2251TEMJ Analogue addressable optical/thermal smoke and heat detector (B501, B501AP, B501DG and B524IEFT-1 bases) Note: Meets the requirements of EN 54-5: 2000 at class A1R and EN 54-7: 2000 at sensitivity settings 1 to 5 Analogue addressable mult-criteria fire detector incorporating CO, photoelectric, thermal and IR sensors (B501, B501AP, B501DG and B524IEFT-1 bases) Note: Certified at the following settings: Normal Mode: Alarm Levels 1 to 5 (Multi-criteria) EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R Nuisance Environment Applications: Application 0, Alarm Level 4 Application 1, Alarm Level 5 Application 2, Alarm Level 4 or 5 Application 3, Alarm Level 5 Application 4, Alarm Level 5 Application 5, Alarm Level 5 Application 6, Alarm Level 5 Bases: B501standard analogue detector base B501AP intelligent detector base B501DG analogue detector deep base B524IEFT-1 analogue short circuit isolator base EN54-7, LPS1279 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA EN54-5 Class A1R, EN54-7 & CEA EN54-5 Class A1R, EN54-7 & CEA EN54-5 Class A1R, EN54-7 & CEA EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA LPCB Ref. No. 199p/02
2251CTLEJ
199t/01
Beam detectors
January 2009
109
Bases: B501 standard analogue detector base B501AP intelligent detector base B501DG analogue detector deep base B524IEFT-1 short circuit isolator base
Notes: 1) The detector has been assessed for compliance with clause 5.15 Fire sensitivity (room protection). 2) The detector has been assessed with PVC (P10.0250) and ABS (B000931) sampling pipes. 3) The approval of the detector is conditional upon the following requirements: -The detector shall be supplied with power from a power supply complying with the requirements of BS EN 54-4. -Design, Installation and commissioning shall be performed in accordance with Kidde Fire Protection Limited Installation, operation & maintenance manual (TM0042) with per hole sensitivities of better than 5%/m, as predicted by the SNIFF Version 3.0 design tool.
Smoke Detectors
Certificated Products FC600/O Conventional photoelectric smoke detector (FC600/BR1000 Resistor mounting base) LPCB Ref. No. 603a/01
110
January 2009
COMMERCIAL DETECTORS
Matrix FZC
PO Box 10559, Ras al Kaymah, UAE Tel: +971 7 2077846 Fax: +971 7 2041010
Certificate No: 603b to EN54-5: 2000 + A1:2002
January 2009
111
Bases: B501 standard analogue detector base B501DG analogue deep base B524IEFT analogue short circuit isolator base HRZ-1000BSD standard base with Schottky diode
Certificate No: 199p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003
Multi-criteria Detectors
Certificated Products MI-PTSE Analogue addressable optical/thermal smoke & heat detector (B501, B501DG & B524IEFT bases) Meets the requirements of EN54-5: 2000 at class A1R and EN54-7: 2000 at sensitivity settings 1 to 5 Conventional photo thermal detector (HRZ-1000BSD base) Analogue addressable multi-criteria detector incorporating photoelectric, thermal and IR sensors (B501, B501AP, B501DG and B524IEFT-1 bases) Note: Certified at the following settings:Normal mode: Alarm Levels 1 to 5 (Multi-criteria): EN54-5 Class A1R, EN54-7 and CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R LPCB Ref. No. 199p/02
HRZ-1002 MI-PTIR
199p/04 199p/05
112
January 2009
COMMERCIAL DETECTORS
Bases: B501 standard analogue detector base B501AP intelligent detector base B501DG analogue sensor deep base B524IEFT analogue short circuit isolator base HRZ-1000BSD standard base with Schottky diode
Bases: B501 analogue detector base B501DG analogue deep base B524IEFT analogue short circuit isolator base HRZ-1000BSD standard base with Schottky diode
Multi-criteria Detectors
Certificated Products MI-PTSE Analogue optical/thermal smoke & heat detector (MI-B501 base) Notes: 1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1 to 5 2) Meets the requirements of EN 54-5:2000 at Class A1R LPCB Ref. No. 550b/03
January 2009
113
Certificate No: 548d to EN 54-7:2000 Certificated Products DET-C102 Bases: DZ-03 Standard detector base Conventional photoelectric smoke detector base) LPCB Ref. No. 548d/01
Heat Detectors
Certificated Products NC-103 NI-103 Conventional heat detector Class A1R (DZ-03 base) Intelligent Rate of Rise Heat Detector Class A1R (DZ-03 base) LPCB Ref. No. 548c/01 548c/02
114
January 2009
COMMERCIAL DETECTORS
Smoke Detectors
Certificated Products NC-102 NI-102 Conventional Photoelectric Smoke Detector (DZ-03 base) Intelligent Photoelectric Smoke Detector (DZ-03 base) LPCB Ref. No. 548d/01 548d/02
Beam Detectors
Certificated Products NI-105/R Intelligent optical beam detector Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 - 1.61 dB Level 2 - 2.31 dB LPCB Ref. No. 548k/01
Multi-Criteria Detectors
Certificated Products NV-I-MS Analogue addressable multisensor detector (NV-IA-SB mounting base) Notes: 1) Certificated at the following settings: Mode 1 - High sensitivity smoke detector with standard heat enhancement Mode 2 - Smoke detection only Mode 3 - Medium sensitivity smoke detector with standard heat enhancement Mode 4 - Low sensitivity smoke detector with high heat enhancement Mode 5 - Class A1 heat detector Also approved in conventional alarm modes 1, 2, 3, 4 and 5. LPCB Ref. No. 010h/01
January 2009
115
Bases; STB - 4EV Mounting base STB - 4SE-EV Mounting base STB - 4 - SE Deep base STB - 4 - SE24VR - Relay base STB - 4 Standard Base
116
January 2009
COMMERCIAL DETECTORS
Certificate No: 041g to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1:2002 and CEA4021: 1999
Multi-criteria Detectors
Certificated Products EV-PH Analogue addressable optical smoke/class A1R heat detector (STB-4EV and STB-4SEEV bases) Note: Meets the requirements of EN 54-7 at 'Lowest' and 'Highest' sensitivity settings. LPCB Ref. No. 041g/01
Notifier By Honeywell
Charles Avenue, Burgess Hill, West Sussex RH15 9UF UK Tel: +44 (0)1444 230300 Fax: +44 (0)1444 230888 E-mail: sales@notifiersystems.co.uk Website: www.notifierfiresystems.co.uk
Certificate No: 199m to EN 54-7: 2000 + A1: 2002 Certificate No: 118h to EN 54-7: 2000 + A1: 2002
Bases: B501 base B401 base B501DG deep base B5241EFT short circuit isolator base
January 2009
117
Bases: B501 base B401 base B401R standard base with resistor B401RSD standard base with resistor and schottky diode B401SD standard base with schottky diode B401DG deep base
Certificate No: 199p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 Certificate No: 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003
Multi-criteria Detectors
Certificated Products SDX-751TEM SD-851TE IRX-751TEM Analogue addressable optical/thermal smoke & heat detector (B501, B501DG and B5241EFT bases) Conventional photoelectric/thermal detector (B401 base) Note: Meets the requirements of EN54-7: 2000 at "High", 'Medium' and 'Low' sensitivity settings Analogue addressable multi-criteria detector incorporating photoelectric, thermal and IR sensors (B501, B501DG and B524IEFT-1 bases) Note: Certified at the following settings: Normal Mode: Alarm Levels 1 to 5 (Multi-criteria): EN54-5 Class A1R, EN54-7 and CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R Analogue addressable multi-criteria fire detector incorporating CO, photoelectric, thermal and IR sensors (B501, B501DG and B524IEFT-1 bases) Note: Certified at the following settings: Normal Mode: Alarm Levels 1 to 5 (Multi-criteria): EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R Nuisance Environment Applications: Application 0, Alarm Level 4 Application 1, Alarm Level 5 Application 2, Alarm Level 4 or 5 Application 3, Alarm Level 5 Application 4, Alarm Level 5 Application 5, Alarm Level 5 Application 6, Alarm Level 5 Bases: B501 base B401 base B501DG deep base B524IEFT-1 analogue short circuit isolator base EN54-7, LPS1279 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA EN54-5 Class A1R, EN54-7 & CEA EN54-5 Class A1R, EN54-7 & CEA EN54-5 Class A1R, EN54-7 & CEA EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA LPCB Ref. No. 199p/02 199p/03 199p/05
IRX-751CTEM
199t/01
118
January 2009
COMMERCIAL DETECTORS
Bases: B501 Standard base B501DG Deep analogue detector base B5242EFT-1 Short circuit islolator base
B501 Standard base B501DG Deep analogue detector base B542IEFT-1 Short circuit islolator base
Bases: B501 standard analogue detector base B501DG deep analogue detector base B5241EFT-1 analogue short circuit isolator base
Novar GmbH
Security and Building Management Systems, Dieseltrasse 2, D-41469, Neuss, Germany Tel: +49 (0)2137 170 Fax: +49 (0)2137 17286 E-mail: info@esser-systems.de Website: www.esser-systems.de
Certificate No: 400m to EN 54-7: 2000 & pr EN 54-17 Draft (July 2002) Certificate No: 400j to EN 54-7:2000
January 2009
119
Certificate No: 400h to EN 54-5: 2000 Certificate No: 400k to EN 54-5: 2000 & pr EN 54-17 Draft (July 2002)
Bases: 781590 standard base 781592 detector base with open collector output 805590 base for series IQ8quad detectors 805591 base for series IQ8quad detectors with relay output
Certificate No: 400g to EN 54-7: 2000 + A1:2002, EN 54-5: 2000 + A1:2002 & CEA4021: 1999 Certificate No: 400n to EN 54-5: 2000, EN 54-7: 2000, pr EN 54-17 Draft (July 2002) & CEA 4021: 1999
Multi-criteria Detectors
Certificated Products OTI-1973 OT-1373 O2T-1374 O2T-803374 O2T-802374 Analogue addressable optical, heat & ionisation multi-sensor detector (781590, 781591 and 781592 bases). Note:Meets EN 54-5: 2000 at class A2S. Analogue addressable optical heat multi-sensor detector (781590, 781591 and 781592 bases) Note:Meets EN 54-5:2000 at class A2S Analogue addressable optical heat multi-sensor detector (781590, 781591 and 781592 bases) Note:Meets EN 54-5:2000 at class A2S. Analogue addressable smoke & heat detector (805590 and 805591 bases) Note:Meets EN 54-5:2000 at class A2S. Analogue addressable smoke & heat detector (805590 and 805591 bases) Note: Meets EN 54-5: 2000 at Class B LPCB Ref. No. 400g/01 400g/02 400g/03 400g/04 400n/01
Bases: 781591 detector base with relay output 805590 base for series IQ8quad detectors 805591 base for series IQ8quad detectors with relay output
OY ESMI AB
Kalkkipellontie 6, PO Box 415, Fl-02601, Espoo, Finland Tel: +358 10 446 511 Fax: +358 10 446 5103 E-mail: Jari.Ollila@esmi.com Website: www.esmi.com
Certificate No: 199p to EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 Certificate No: 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003
120
January 2009
COMMERCIAL DETECTORS
ESMI2251CTLE
199t/01
Photain Controls
8 New Market Court, Chippenham Drive, Kingston, Milton Keynes BN18 0BE UK Tel: 01908 281981 Fax: 01908 282554 E-mail: john.davies@ge.com
Certificate No: 092p to EN 54-5: 2000
Heat Detectors
Certificated Products PHDP2004 PRRP2004 PHDP2004HT Conventional Class A1heat detector (FSBP 2000 base) Conventional Class A1R heat detector (FSBP 2000 base) Conventional Class B heat detector (FSBP 2000 base) LPCB Ref. No. 092p/02 092p/03 092p/04
Smoke Detectors
Certificated Products ISDP2004 PPDP2004 Conventional ionisation smoke detector (FSBP2000 base) Conventional photoelectric smoke detector (FSBP2000 base) LPCB Ref. No. 092n/03 092n/04
January 2009
121
Bases: 2020B standard base 2020DB deep base 2020BSD standard base with schottky diode 2020DBSD deep base with schottky diode B401 standard base B401DG deep base B401R standard base with 470 ohm resistor B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B501 standard analogue detector base B501AP intelligent detector base B501DG analogue sensor deep base B524IEFT analogue sensor isolator base B524IEFT-1 analogue short circuit isolator base ECO1000B standard base. ECO1000BSD standard base with schottky diode. ECO1000BR standard base, 470 ohm resistor. ECO1000BRSD standard base, 470 ohm resistor and schottky diode. ECO1000BR680 standard base, 680 ohm resistor. ECO1000BR680SD standard base, 680 ohm resistor and schottky diode. ECO1000BR1000 standard base, 1000 ohm resistor. ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode. ECO1000DB deep base ECO1000DBR deep base with 470 ohm resistor ECO1000DBRSD deep base with 470 ohm resistor and schottky diode ECO2000B mounting base.
122
January 2009
COMMERCIAL DETECTORS
5351E 4351E ECO1004T Vision 2020F Vision 2020HF Vision 2020R 5451EIS 5351TE
Bases: 2020B standard base 2020DB deep base 2020BSD standard base with schottky diode 2020DBSD deep base with schottky diode B401 standard base B401DG deep base B401R standard base with 470 ohm resistor B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B401R1000 standard base with 1000 ohm resistor B401DGR deep base with 470 ohm resistor B401DGR1000 deep base with 1000 ohm resistor B401DGSD deep base with schottky diode B501 standard analogue detector base B501AP intelligent detector base B501DG analogue sensor deep base B524IEFT analogue sensor isolator base ECO1000B standard base. ECO1000BSD standard base with schottky diode. ECO1000BR standard base, 470 ohm resistor. ECO1000BRSD standard base, 470 ohm resistor and schottky diode. ECO1000BR680 standard base, 680 ohm resistor. ECO1000BR680SD standard base, 680 ohm resistor and schottky diode. ECO1000BR1000 standard base, 1000 ohm resistor. ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode. ECO2000B mounting base. ECO1000DB deep base. ECO1000DBR deep base with 470 ohm resistor ECO1000DBRSD deep base with 470 ohm resistor and schottky diode.
Certificate No: 199p to EN 54-5: 2000 + A1:2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 Certificate No: 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003
Multi-criteria Detectors
Certificated Products ECO1002 Conventional photo-thermal detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR and ECO1000DBRSD bases) Note :Meets the requirements of EN54:5-2000 at class A1R and EN54:7:2000 at pre-set sensitivity Analogue addressable optical/thermal smoke & heat detector B501AP, B501DG and B5241EFT bases) Note: Meets the requirements of EN 54-5:2000 at class A1R and EN 54-7:2000 at LPCB Ref. No. 199p/01
2251TEM
199p/02
January 2009
123
199p/04 199p/05
2251CTLE
199t/01
Bases: 2020B standard base 2020DB deep base 2020BSD standard base with schottky diode 2020DBSD deep base with schottky diode B401 standard base B401DG deep base B401R standard base with 470 ohm resistor B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B401R1000 standard base with 1000 ohm resistor B401DGR deep base with 470 ohm resistor B401DGR1000 deep base with 1000 ohm resistor B401DGSD deep base with schottky diode B501 standard analogue detector base B501AP intelligent detector base B501DG analogue sensor deep base B524IEFT analogue sensor isolator base ECO1000B standard base ECO1000BSD standard base with schottky diode ECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diode ECO1000BR680 standard base, 680 ohm resistor ECO1000BR680SD standard base, 680 ohm resistor and schottky diode ECO1000BR1000 standard base, 1000 ohm resistor ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode ECO1000DB deep base ECO1000DBR deep base with 470 ohm resistor ECO1000DBRSD deep base with 470 ohm resistor and schottky diode ECO2000B mounting base B524IEFT-1 analogue short circuit isolator base
124
January 2009
COMMERCIAL DETECTORS
Plana Fabrega
Rudford Estate, Ford Aerodrome, Arundel, West Sussex BN18 0BE UK Tel: +44 (0)1908 281981 Fax: +44 (0)1908 282554
Certificate No: 092p to EN 54-5: 2000
Heat Detectors
Certificated Products T-7004 TV-7003 T-7005 Conventional Class A1 heat detector (BD-21 and BD-22 bases) Conventional Class A1R heat detector (BD-21 and BD-22 bases) Conventional Class B heat detector (BD-21 and BD-22 bases) LPCB Ref. No. 092p/02 092p/03 092p/04
Smoke Detectors
Certificated Products I-7001 O-7002 Conventional ionisation smoke detector (BD-21 and BD-22 bases) Conventional photoelectric smoke detector (BD-21 and BD-22 bases) LPCB Ref. No. 092n/03 092n/04
Bases: 6000/BASE standard low profile base 6000/DIB isolator base 3000/BASE Standard Base
January 2009
125
Bases: 3000/BASE standard base 6000/BASE standard low profile base 6000/DIB isolator base
201h to EN 54- 7: 2000 + A1: 2002 and CEA 4021: 2003 201j to EN 54: Part 5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 and CEA 4021: 2003 201q to EN 54-5: 2000, EN 54-7: 2000 and CEA 4021 201s to EN 54-5: 2000, EN 54-7: 2000 and CEA 4021
Multi-criteria Detectors
Certificated Products 6000/OPHT Analogue addressable optical smoke detector with thermal enhancement (6000/BASE and 6000/DIB bases) Note: 1) Meets requirements of EN 54: 7: 2000 and CEA 4021 at the following mode settings only: i. Medium sensitivity combination ii. Low sensitivity combination iii. High performance optical mode Conventional optical smoke and Class A2 heat detector (3000/BASE) Analogue addressable optical smoke and Class A2 heat multisensor detector (6000/BASE & 6000/DIB bases). Note: 1) Meets requirements of EN 54-7: 2000 and CEA 4021 at the following mode settings only: i. Normal sensitivity mode ii. Low sensitivity mode Analogue addressable optical smoke, CO and Class A2 heat multisensor detector (6000/BASE & 6000/DIB bases) Notes: 1) Meets requirements of EN 54-7: 2000 and CEA 4021 at the following mode settings only: i. Normal sensitivity mode ii. Low sensitivity mode 2) The CO element is not LPCB approved LPCB Ref. No. 201h/01
3000/OPHT Mk II 6000/OPHT Mk II
201j/01 201q/01
6000/OPHTCO
201s/01
Bases: 3000/BASE standard base 6000/BASE standard low profile base 6000/DIB isolator base
126
January 2009
COMMERCIAL DETECTORS
Multi-criteria Detectors
Certificated Products 203-0001 Sita200plus Multipoint Intelligent Addressable Optical smoke, heat detector and sounder, incorporating short circuit isolator and auxiliary input/output. Notes: Approved for use with smoke sensitivities SM1-SM3, heat sensitivity HM1(Class A2), HM2(Class A2) and HM3(Class C), sound output settings SP1-SP7 when set to medium and high volume only. Multipoint Intelligent Addressable Optical smoke, heat detector and sounder, incorporating short circuit isolator and auxiliary input/output Notes: Approved for use with smoke sensitivities SM1-SM3 and heat sensitivity HM1(Class A2), HM2(Class A2) and HM3(Class C). LPCB Ref. No. 331b/01
203-0003 Sita200plus
331b/02
Smoke Detectors
Certificated Products RE-1003 P Bases: RE-1000B Standard base Conventional photoelectric smoke detector (RE-1000B base) LPCB Ref. No. 550a/02
Certificate No: 550b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 1999
Multi-criteria Detectors
Certificated Products RE-1002 PT Conventional photo-thermal detector (RE-1000B base) Note: Meets the requirements of EN54-5:2000 at class A1R at pre-set sensitivity LPCB Ref. No. 550b/02
Heat Detectors
Certificated Products RE-1005 R Bases: Conventional A1R rate-of-rise heat detector (RE-1000B base) LPCB Ref. No. 550c/03
January 2009
127
Sareme UAB
Naugarduko str. 32/2, Vilnius LT2006, Lithuania Tel: +3705 2135047 Fax: +3705 2333567 E-mail: sareme@sareme.lt
Certificate No: 512d to EN 54-5: 2000
Heat Detectors
Certificated Products EA323-2 EA323-4 Conventional 2 wire 24 VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base) Conventional 4 wire 12VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base) LPCB Ref. No. 512d/01 512d/05
LTS240
648b/01
128
January 2009
COMMERCIAL DETECTORS
Beam Detectors
Certificated Products D-A430/R Intelligent optical beam detector Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 - 1.61 dB Level 2 - 2.31dB LPCB Ref. No. 548k/01
Smoke Detectors
Certificated Products D-C401 D-A411 Bases: DZ-03 Standard detector base Conventional photoelectric smoke detector (DZ-03 base) Intelligent photoelectric smoke detector (DZ-03 base) LPCB Ref. No. 548d/01 548d/02
Heat Detectors
Certificated Products D-C402 D-A412 Bases: DZ-03 Standard detector base Conventional Class A1R heat detector (DZ-03 base) Intelligent Class A1R heat detector (DZ-03 base) LPCB Ref. No. 548c/01 548c/02
January 2009
129
UK Sales: Siemens Building Technologies Limited, FSP Division Tel: +44 (0)1784 461616 Fax: +44 (0)1784 464646
126x to EN 54:7: 2000 126ab to EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA GEI 1-052: DRAFT 2.0, 11/06/97 126am to EN 54-7: 2000 + A1: 2002 531c
Bases: Z94 base FDB221 base FDB201 base "Collective" FDB291 base attachment surface FDB292 base attachment surface wet DB1101A base DB1131A base DB1151A base DBZ1191 base attachment
130
January 2009
COMMERCIAL DETECTORS
Certificate No: 126aa to EN 54-5: 2000 + A1: 2002 and CEA GEI 1-052: Draft 2.0, 11/06/97 Certificate No: 126an to EN 54-5: 2000 + A1: 2002 Certificate No: 531b to EN 54-5: 2000 + A1: 2002
Bases: Z94 base DFB1190 base FDB221 base FDB201 base Collective FDB291 base attachment surface FDB292 base attachment surface wet DB1101A base for conventional addressing DB1131A base for analogue addressing DB1151A base for interactive fire detectors TM SO320 base for Synova 300 series detectors SO620 Analogue addressable (AnalogPLUS) detector base SO820 Analogue addressable (Interactive) detector base
Certificate No: 126ag to EN 54-12: 2002 and CEA GEI 1-052: Draft 2.0, 11/06/97 Certificate No: 126ak to EN 54-12: 2002
Beam Detectors
Certificated Products FDL241-9 DLO1191 Analogue addressable beam detector (FDLB291 base) Note: Certified at sensitivity setting 30%, 50% and 65% Optical beam smoke detector (DLB1191A base) Note: Certified at sensitivity setting 30%, 50% and 65% LPCB Ref. No. 126ag/01 126ak/01
Certificate No: 126s to EN 54-10: 2002 Certificate No: 126af to EN 54-10: 2002 and CEA GEI 1-052: Draft 2.0, 11/06/97
January 2009
131
Certificate No: 126ah to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & CEA GEI 1-052: Draft 2.0, 11.06.97
Multi-criteria Detectors
Certificated Products FDOOT241-9 Analogue addressable multisensor detector with short circuit isolator (FDB221, FDB201, FDB291 and FDB292 bases) Note: Meets the requirements of EN 54-5: 2000 at Class A2R & A2S and EN 54-7: 2000 at sensitivity settings: Parameter No. 1 Universal Parameter No. 2 Robust with thermal enhancement Parameter No. 3 Sensitive Parameter No. 4 balanced with thermal enhancement Parameter No. 5 Suppression with thermal enhancement Parameter No. 6 Response with thermal enhancement Parameter No. 7 Robust / BGD with thermal enhancement Analogue addressable multisensor detector with short circuit isolator (FDB221, FDB201, FDB291 and FDB292 bases) Note: Meets the requirements of EN 54-5: 2000 at Class A2R & A2S and EN 54-7: 2000 at sensitivity settings: Parameter No. 2 Robust with thermal enhancement Parameter No. 4 balanced with thermal enhancement LPCB Ref. No. 126ah/01
FDOOT221
126ah/02
Bases: FDB221 base FDB201 base Collective FDB291 base attachment surface FDB292 base attachment surface wet
132
January 2009
COMMERCIAL DETECTORS
System Sensor
3825 Ohio Avenue, Saint Charles, Illinois 60174, USA Tel: +1 630 377 6580 Fax: +1 630 377 7245 Website: www.systemsensor.com European Sales Enquiries: System Sensor Europe Tel: +44 (0)1403 891920 Fax: +44 (0)1403 891921
Bases: B501 analogue sensor base B501AP intelligent detector base B501DG deep base B524IEFT short circuit isolator base B524IEFT-1 short circuit isolator base
EC01003 2251EM
550a/02 550a/03
January 2009
133
Certificate No: 550b to EN 54-5: 2000 + A1: 2002, EN 54-7:2000 + A1: 2002 & CEA 4021: 1999
ECO1002
550b/02
2251TEM
550b/03
Bases: B401 standard base B401DG deep base B401R standard base with schottky diode B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B401R1000 standard base with 1000 ohm resistor B401DGR deep base with 470 ohm resistor B401DGR1000 deep base with 1000 ohm resistor B401DGSD deep base with schottky diode ECO1000B standard base ECO1000BSD standard base with schottky diode ECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diode ECO1000BR680 standard base, 680 ohm resistor ECO1000BR680SD standard base, 680 ohm resistor and schottky diode ECO1000BR1000 standard base, 1000 ohm resistor ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode B501 standard analogue detector base B501DG deep analogue detector base B5241EFT-1 analogue short circuit isolator base
134
January 2009
COMMERCIAL DETECTORS
4351E
550c/02
Bases: B401 standard base B401DG deep base B401R standard base with schottky diode B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B401R1000 standard base with 1000 ohm resistor B401DGR deep base with 470 ohm resistor B401DGR1000 deep base with 1000 ohm resistor B401DGSD deep base with schottky diode ECO1000B standard base ECO1000BSD standard base with schottky diode ECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diode ECO1000BR680 standard base, 680 ohm resistor ECO1000BR680SD standard base, 680 ohm resistor and schottky diode ECO1000BR1000 standard base, 1000 ohm resistor ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode
Flame Detectors
Certificated Products 016589 016689 016579 016679 016519 016619 016581 016681 016571 Conventional IR Flame Detector (007127) Note: Meets EN 54-10:2002 at Class 1 only 3 Analogue Addressable IR Flame Detector (007127) Note: Meets EN 54-10:2002 at Class 1 only 3 Conventional IR Intrinsically Safe Flame Detector (007127) Note: Meets EN 54-10:2002 at Class 1 only 3 Analogue Addressable IR Intrinsically Safe Flame Detector (007127) Note: Meets EN 54-10:2002 at Class 1 only 3 Conventional IR (Exd) Flameproof Flame Detector (007127) Note: Meets EN 54-10:2002 at Class 1 only 3 Analogue Addressable IR (Exd) Flameproof Flame Detector (007127) Note: Meets EN 54-10:2002 at Class 1 only 2 Conventional IR Flame Detector (007127) Note: Meets EN 54-10: 2002 at Class 1 only 2 Analogue Addressable IR Flame Detector (007127) Note: Meets EN 54-10: 2002 at Class 1 only 2 Conventional IR Intrinsically Safe Flame Detector (007127) Note: Meets EN 54-10: 2002 at Class 1 only
3
LPCB Ref. No. 729a/01 729a/02 729a/03 729a/04 729a/05 729a/06 729a/07 729a/08 729a/09
January 2009
135
Smoke Detector
Certificated Products FSV-OPT Bases: FSV-CDB Standard base Conventional photoelectric smoke detector (FSV-CDB base) LPCB Ref. No. 603a/01
Heat Detectors
Certificated Products 801H 601H-R 601H-F MD601Ex MD611Ex 816H MX Digital addressable heat detector (801B, 801IB, 801RB and 801SB Bases) Note: Meets EN54 Part 5 for classes A1R, A2S and CR. Conventional Class A1R heat detector (MUB and 5B mounting bases) Conventional Class A1S heat detector (MUB and 5B mounting bases) Conventional intrinsically safe Class A1R rate of rise heat detector (MUBEx base, 5BEx base) Conventional intrinsically safe Class A1S fixed temperature heat detector (MUBEx base, 5BEx base) MX Digital addressable heat detector (801B, 801IB, 801RB, 801SB and 5BI 5 bases) Note: Meets EN54 Part 5 for classes A1R, A2S and CR. LPCB Ref. No. 681c/01 681c/02 681c/03 681c/04 681c/05 681c/06
Bases:
136
January 2009
COMMERCIAL DETECTORS
Certificate No: 681q to LPS 1274 Issue 1, CEA 4021:2003, EN 54-7:2000, and EN 54-5:2000 Certificate No: 681j to EN 54-7:2000 and CEA 4021:1999 and AI:2002
Multi-criteria Detectors
Certificated Products 601PH MR601Tex 816PH 801PC Conventional high performance optical smoke detector (MUB and 5B mounting bases) Conventional intrinsically safe high performance optical smoke detector with heat enhancement (MUBEx base, 5BEx base) MX Digital addressable photoelectric detector with heat enhancement (801B, 801IB, 801RB, 801SB and 5BI 5 bases) Note: Meets EN54 Part 7 at Normal sensitivity Analogue addressable combined optical, heat and CO fire detector 5B, 5BI, 801SB, 801RB, 802SB, 901SB, and DHM-5B bases) Notes: 1) Certificated at the following modes: Mode 0 - Universal multi-criteria (smoke /heat/CO) wide spectrum fire detection with Class A2S heat detection Mode 1 - Multi-criteria (smoke /heat/CO) fire detection with high false alarm immunity with Class A2S heat detection Mode 2 - Class A1R heat detection Mode 3 - Thermally enhanced smoke detection Mode 4 - Thermally enhanced CO detection 2) Meets the requirements of LPS 1274 at modes 0 and 4, CEA 4021 and EN 547 at modes 0, 1 and 3, and EN 54-5 at modes 0, 1, and 2. Analogue addressable combined optical, heat and CO fire detector( marine version) (MUB, 5B, 5BI, 801SB, 801RB, 802SB, 901SB, and DHM-5B bases) Notes: 1) Certificated at the following modes: Mode 0 - Universal multi-criteria (smoke /heat/CO) wide spectrum fire detection with Class A2S heat detection Mode 1 - Multi-criteria (smoke /heat/CO) fire detection with high false alarm immunity with Class A2S heat detection Mode 2 - Class A1R heat detection Mode 3 - Thermally enhanced smoke detection Mode 4 - Thermally enhanced CO detection 2) Meets the requirements of LPS 1274 at modes 0 and 4, CEA 4021 and EN 547 at modes 0, 1 and 3, and EN 54-5 at modes 0, 1, and 2. LPCB Ref. No. 681j/01 681j/02 681j/03 681q/01
811PC
681q/02
Bases: MUBEx intrinsically safe detector base 801B Minerva universal mounting base 801IB addressable isolator base 801RB addressable relay base 801SB addressable sounder base 5BI 5 Isolator base MUB Universal mounting base 5B 5 Universal mounting base 802SB - Mk II Sounder base 901SB - Mk II Sounder base DHM-5B - Deck head mounting adaptor for 5" base 5BEx Intrinsically safe mounting base
Certificate No: 763a to EN 54-10: 2002 Certificate No: 681r to EN 54-10: 2002
January 2009
137
Bases: MUB standard mounting base 5B standard mounting base 5BI addressable isolator base 801IB addressable isolator base
Smoke Detectors
Certificated Products 801I 601I 601P 816P MX Digital addressable ionisation smoke detector (801B, 801IB, 801RB and 801SB bases) Note: Meets EN54 Part 7 in normal and high sensitivity settings only. Conventional ionisation smoke detector (MUB and 5B 5" mounting bases) Conventional optical smoke detector (MUB and 5B 5" mounting bases) MX Digital addressable photoelectric detector (801B, 801IB, 801RB, 801SB and 5BI 5 bases) Note: Meets EN54 Part 7 at normal and high sensitivity LPCB Ref. No. 681d/01 681d/02 681d/03 681d/05
Bases: 801B Minerva universal mounting base 801IB addressable isolator base 801RB addressable relay base 801SB addressable sounder base MUB Universal mounting base 5B 5 Universal mounting base 5BI 5 Isolator base
Bases:
138
January 2009
COMMERCIAL DETECTORS
January 2009
139
140
January 2009
COMMERCIAL DETECTORS
European Operations at: Xtralis (UK) Limited, Vision House, Focus 3, Mark Road, Hemel Hempstead, Hertfordshire HP2 7BW UK Tel: +44 (0)1442 242330 Fax: +44 (0)1442 249327
Certificate No: 305b to GEI 1 - 048 30-01-97 Certificate No: 305c to CEA 4022: 1999
VESDA LaserSCANNER
305b/02
VESDA LaserCOMPACT
305b/03
January 2009
141
305c/01
LaserFOCUS VLF500
305c/02
Certificate No: 305d to EN 54-20: 2006 Certificated Products VESDA VLF-250 high sensitivity aspirating smoke detector Incorporating the following ancilliary equipment: - VIC-010 VESDAnet network card - VRT-V00 Remote VLF display (with 7 relays) - VRT-W100 Remote VLF display (no relays) - VRT-500 Remote relay unit (with 7 relays) 1) For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming with the requirements of EN 54-4. 2) The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3) System design, installation and commissioning shall be performed in accordance with the VESDA VLF product guide. Incorporating the following ancillary equipment: - VIC-010 VESDAnet network card - VRT-V00 Remote LaserFOCUS display (with 7 relays) - VRT-W00 Remote LaserFOCUS display (no relays) - VRT-500 Remote relay unit (with 7 relays) 1) For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming with the requirements of EN 54-4. 2) The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3) System design, installation and commissioning shall be performed in accordance with the VESDA VLF product guide. 4) Remote display, programmer and relay modules are also approved in a 19" LPCB Ref. No. 305d/01
305d/02
142
January 2009
COMMERCIAL DETECTORS
305d/04
305d/05
January 2009
143
For domestic applications, care needs to be taken over the correct choice of the type of detector, its siting and the condition of batteries in order to maintain the alarm in accordance with the manufacturers requirements. Further guidance is available from LPCB if required. Audit: Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Note: 1. EN 14604:2005 supersedes BS 5446-1:2000 which was withdrawn in July 2008. Information concerning the date of withdrawal of conflicting standards in the foreword to EN 14604:2005 is incorrect. The correct data is given in the Foreword to the UK version of BS EN 14604:2005 and gives the date of withdrawal of BS 5446:1:2000 as July 2008. However, EN 14604:2005 is now a harmonised standard for the Construction Products Directive and CE marking will be required for most of the European market by 01 August 2008. It is therefore recommended that detectors are certificated to EN 14604:2005 as soon as possible.
Smoke Alarm
Certificated Products M816VS Stand alone photoelectric smoke alarm detector with RF transmitter. Note: The RF transmitter is not approved. LPCB Ref. No. 512c/01
144
January 2009
Smoke Alarms
Certificated Products SD-176H SD-196H SD-170H SD-1982 SD-1782 Battery operated ionisation smoke alarm with alarm silence feature Battery operated photoelectric smoke alarm with alarm silence feature Battery operated ionization smoke alarm 9v battery operated photoelectric smoke alarm with alarm silence feature 9v battery operated ionisation smoke alarm with alarm silence feature LPCB Ref. No. 679a/01 679a/02 679a/03 679a/04 679a/05
Smoke Alarm
Certificated Products SD-176H SD-170H Battery operated ionisation smoke alarm with alarm silence feature Battery operated ionisation smoke alarm LPCB Ref. No. 679b/01 679b/02
Certificate No: 651d to EN 14604: 2005 Certificate No: 651a to BS 5446-1: 2000
Smoke Alarms
Certificated Products EZ-212 SI-1 SO-1 SI-6 SO-6 SI-10 SO-10 BI-1 SI 601 SI 610 WSI 601 Hard Wired Smoke Alarm 9v battery operated ionisation smoke alarm with alarm silence feature 9v battery operated photoelectric smoke alarm with alarm silence feature 9v battery operated ionisation smoke alarm with alarm silence feature and 10 year lithium battery 9v battery operated photoelectric smoke alarm with alarm silence feature and 10 year lithium battery Battery operated ionisation smoke alarm with alarm silence feature Battery operated photoelectric smoke alarm with alarm silence feature 9v battery operated ionisation smoke alarm Battery operated ionisation smoke alarm Battery operated ionisation smoke alarm Battery operated ionisation smoke alarm with RF transmitter module LPCB Ref. No. 651a/01 651a/02 651a/03 651a/04 651a/05 651a/06 651a/07 651a/08 651d/01 651d/02 651d/03
January 2009
145
Visonic
24 Habarzel Street, Tel Aviv 69710, Israel Tel: +44 (0)870 7300810 Fax: +44 (0)870 7300801 E-mail: DalitS@visonic.com Website: www.visonic.com
Certificate No: 512e to EN 50291: 2001
146
January 2009
SECTION 5: PART
The purpose of a manual call point is to enable a person discovering a fire to initiate the operation of a fire alarm system so that appropriate measures can be taken. Therefore it is important for the manual call point to be recognizable and simple to use. For this reason, the European standard has attempted to standardised their appearance and function. There are basically two types of manual call points which are related to the method of operation. - Type A: direct operation (single action). - Type B: indirect operation (double action). Both types require the breaking or the visible displacement by change of position of a frangible element forming part of the front face. Guidance on the selection, siting and speed of response should be sought from the applicable installation rule or code of practice (e.g. BS 5839-1). For example BS 5839-1 recommends only type A with a speed of evacuation signal within 3 seconds. Other codes of practice, may require a type B installation. This section lists manual call points approved for use in fire detection and fire alarm systems in buildings. The initial approval and continued approval processes for manual call points are outlined in scheme document SD041. Products listed in this section have been approved to: EN 54-11:2001 Manual call points EN 54-11:2001 + A1:2005 Manual call points ISO 7240-11:2005 Manual call points
Audit: Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Notes: 1. EN 54-11:2001 supersedes BS 5839-2:1983 which was withdrawn in November 2003. EN 54-11:2001 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market from 1 September 2008. 2. Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.
January 2009
147
PART 3: SECTION 5
MANUAL CALL POINTS
AMPAC Industries
97 Walters Drive, Osbourne Park, Western Australia 6017, Australia Tel: +618 (9242) 3333 Fax: +618 (9242) 3334 Website: www.ampac.net
Certificate No: 010n to EN 54-11:2001 Certificate No: 010w to EN 54-11:2001 and EN 54-17:2005 Certificated Products 213-0050 213-0052 213-0051 213-0053 Analogue addressable manual call point with surface mounting box Analogue addressable manual call point with surface mounting box Analogue addressable manual call point with short circuit isolator and surface mounting box Analogue addressable manual call point with short circuit isolator and surface mounting box LPCB Ref. No. 010n/02 010n/06 010w/01 010w/03
Sales Enquiries Spain, Apollo Espana Tel: +34 627 988 061 Fax: +34 949 335 289 E-mail: apollo.espana@apollo-fire.com
Sales Enquiries, China Apollo Fire Detectors Limited, Shanghai representative office Tel: +86 21 5237 0922 Fax: +86 21 5237 0920 E-mail: tony.ye@apollo-fire.com
Certificate No: 010d to BS 5839: Part 2:1983 Certificate No: 010n to EN 54-11: 2001 Certificate No: 010w to EN 54-11: 2001 and EN 54-17: 2005 Certificated Products 55000-900 XP95 55000-940 XP95 IS 55000-950 XP95 58000-900 Discovery 58000-910 Discovery 58000-920 Discovery Analogue addressable flush and surface mounted manual call point Certificated with Apollo, Series 90 and XP95 communication protocols Analogue addressable intrinsically safe manual call point Certificated with Apollo, Series 90 and XP95 communication protocols Analogue addressable waterproof manual call point Certificated with Apollo, Series 90 and XP95 communication protocols Analogue addressable flush and surface mounted manual call point Certificated with Series 90, XP95 and Discovery digital communication protocols Analogue addressable flush mounted manual call point Certificated with Series 90, XP95 and Discovery digital communication protocols Analogue addressable surface mounted manual call point Certificated with Series 90, XP95 and Discovery digital communication protocols LPCB Ref. No. 010d/06 010d/03 010d/04 010d/05 010d/05 010d/05
148
January 2009
SECTION 5: PART
Certificated Products 59000-910 XPlorer 55100-905 XP95 58100-910 Discovery 55100-908 XP95 58100-908 Discovery 58100-905 Discovery XPA-MC-14006-APO Analogue addressable surface mounted manual call point Certificated with Series 90 and XP95 digital communication protocols Certificated with the Burgess V3NCSET7 Mk 1 microswitch Analogue addressable manual call point with surface mounting box Analogue addressable manual call point with surface mounting box Analogue addressable manual call point with short circuit isolator and surface mounting box Analogue addressable manual call point with short circuit isolator and surface mounting box Analogue addressable manual call point with short circuit isolator, glass frangible element and surface mounting box Xpander addressable radio linked manual call point Notes: 1) The device must be used with the following batteries only: - MN1500 LR6 - 1.5 volt alkaline AA cells 2) The radio link functionality is not included within the scope of approval Analogue addressable waterproof manual call point Analogue addressable intrinsically safe manual call point. Analogue addressable waterproof manual call point with short circuit isolator LPCB Ref. No. 010n/01 010n/02 010n/06 010w/01 010w/03 010w/05 010ae/01
January 2009
149
PART 3: SECTION 5
MANUAL CALL POINTS
150
January 2009
SECTION 5: PART
Manual Call Points
Certificated Products EM921 EM921-F EM921-TC EM921-FTC Accessories: EM921B1 EM921B2 EM921B3 Conventional manual call point with LED Conventional manual call point with flashy LED Convetnional manual call point with LED and transparent cover Conventional manual call point with flashy LED and transparent cover LPCB Ref. No. 512f/01 512f/02 512f/03 512f/04
Regular mounting base, 28mm High mounting base, 40mm High mounting base, 55m
Accessories: Fireguard FG921B1 Regular mounting base, 28mm Fireguard FG921B2 High mounting base, 40mm Fireguard FG921B3 High mounting base, 55m
Fulleon Limited
Llantarnam Park, Cwmbran, Gwent NP44 3AW UK Tel: +44 (0)1633 628500 Fax: +44 (0)1633 866346 E-mail: sales@fulleon.co.uk Website: www.fulleon.com
Certificate No: 378c to EN 54: Part 11: 2001 Certificated Products CX/G/R/BB CX/P/R/NB CX/P/R/BB CXL/GP/R/BB CXL/GP/R/NB Conventional re-settable indoor manual call point, with surface mount back box* Conventional indoor manual call point, flush mounted* Conventional indoor manual call point, with surface mount back box* Conventional type A glass or plastic re-settable indoor manual call point, with surface mount back box Conventional type A glass or plastic re-settable indoor manual call point, flush mounted LPCB Ref. No. 378c/01 378c/02 378c/02 378c/03 378c/03
January 2009
151
PART 3: SECTION 5
MANUAL CALL POINTS
Certificated Products CXL/GP/R/WP CXL/GP/R/BB CXL/GP/R/NB CXL/GP/R/WP Conventional type A Conventional type A mount back box Conventional type A Conventional type A glass or plastic re-settable indoor/outdoor manual call point glass or plastic re-settable indoor manual call point, with surface glass or plastic re-settable indoor manual call point, flush mounted glass or plastic re-settable indoor/outdoor manual call point LPCB Ref. No. 378c/04 378c/05 378c/05 378c/06
* Approved with V4NCSET7 Mk1 or V4NSET7-UL micro switches only. Accessories: /BB surface mounted (plastic back box)
GE Security (Aritech)
Kelvinstraat, 7, NL-6003 DH Weert, The Netherlands Tel: +31 (495) 456735 Fax: +31 (495) 550042 Website: www.gesecurity.com
Certificate No: 010n to EN 54-11: 2001 Certificate No: 010w to EN 54-11: 2001 and EN 54-17: 2005 Certificated Products DMN 960 DMN 990 DMN 960I DMN 990I Analogue addressable manual call point with surface mounting box Analogue addressable manual call point with surface mounting box Analogue addressable manual call point with short circuit isolator and surface mounting box Analogue addressable manual call point with short circuit isolator and surface mounting box LPCB Ref. No. 010n/02 010n/06 010w/01 010w/03
GE Security Inc
5 North Main Street, Pittsfield, ME 04967, USA Tel: +1 207 487 3104 Fax: +1 207 487 5526 E-mail: leon.newsome@ge.com Website: www.gesecurity.com European Sales: Rudford Estate, Ford Aerodrome, Arundel, West Sussex BN18 0BE UK Tel: +44 (0)1903 711 440 Fax: +44 (0)1903 711 448 E-mail: info@estinternational.com
Certificate No: 262p to EN 54-11: 2001 Certificate No: 092r to EN 54-11: 2001
152
January 2009
SECTION 5: PART
Certificated Products SIGI-271 EA785-3 Accessories SR3T-P Surface mounted box ETT1-P Flush mounted box Digital addressable indoor manual call point, surface or flush mounted Analogue addressable manual call point LPCB Ref. No. 262p/01 092r/01
Gent By Honeywell
140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN UK Tel: +44 (0)116 246 2000 Fax: +44 (0)116 246 2300 E-mail: gent_enquiry@gent.co.uk Website: www.gent.co.uk Middle East Sales Enquiries: E-mail: gent.export@honeywell.com
Certificate No: 042c to BS 5839: Part 2 Certificate No: 567c to BS 5839: Part 2 Certificate No: 042aq to EN 54-11: 2001 Certificated Products 1195 OR 34800 78150-52NM 34800 34800-EN Vigilon 34842-EN Vigilon S4-34800 Flush and surface mounted manual call point Flush and surface mounted addressable manual call point Note: Approved for flush mounting when using 13480-29 flush mounting plate Flush and surface mounted addressable manual call point. Note: Approved for flush mounting when using 78150-98NM flush mounting plate Flush and surface mounted addressable manual call point (indoor) Note: Approved for flush mounting when using 13480-29 flush mounting plate Analogue addressable Type A surface mount manual call point Analogue addressable Type A surface mount manual call point with protective cover Analogue addressable Type A indoor manual call point (S4-34895 surface mount back box) Notes: 1) Approved for use with re-settable and non re-settable element Analogue addressable Type A indoor manual call point with protective cover (S4-34895 surface mount back box) Notes: 1) Approved for use with re-settable and non re-settable element LPCB Ref. No. 042c/01 042c/03 042c/05 567c/01 042aq/03 042aq/04 042aq/01
S4-34842
042aq/02
January 2009
153
PART 3: SECTION 5
MANUAL CALL POINTS
Gulf Security Technology Co. Ltd (Manufacturing Division of Global System Technology PLC)
No. 80 Changjiang East Road, Economic & Technological Development Zone, Qinhuangdao, Hebei Province 066004, Peoples Republic of China Tel: +86 0335 8502528 Fax: +86 0335 8508942 E-mail: gst@gst.com.cn Website: www.gst.com.cn
Certificate No: 548g to EN 54-11: 2001 Certificated Products J-SAF-GST9211 (E) J-SAM-GST9111 (E) Conventional manual call point Intelligent manual call point LPCB Ref. No. 548g/01 548g/02
HDR
Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA UK Tel: +44 (0)1634 260133 Fax: +44 (0)1634 260132 E-mail: info@hochikieurope.com Website: www.hochikieurope.com
Certificate No: 164j to EN 54-11:2001 Certificated Products 1440270 1440300 Addressable Manual Call Point (SR and SR1T mounting boxes) Weatherproof Addressable Manual Call Point (SR and SR1T mounting boxes) LPCB Ref. No. 164j/01 164j/04
Ancillaries: SR Surface mounting plastic box SR1T Surface mounting plastic box c/w 1 terminal
154
January 2009
SECTION 5: PART
Certificated Products HCP-E(HFP) HCP-EF HCP-E(DPS) HCP-W(HFP) HCP-W(DPS) Addressable Manual Call Point (SR and SR1T mounting boxes) Addressable Manual Call Point - French - (SR and SR1T mounting boxes) Addressable Manual Call Point - with Dual Pole Switching - (SR and SR1T mounting boxes) Weather Proof Addressable Manual Call Point (SR and SR1T mounting boxes) Weather Proof Addressable Manual Call Point with Dual Pole Switching (SR and SR1T mounting boxes) LPCB Ref. No. 164j/01 164j/02 164j/03 164j/04 164j/05
Notes: 1) Approved in normal mode only 2) Include Swedish and Finnish language variants Accessories: SR Surface mounting plastic box SR1T Surface mounting plastic box c/w 1 terminal
January 2009
155
PART 3: SECTION 5
MANUAL CALL POINTS
Certificated Products Apachi AP921-TC Accessories: Apachi AP21B1 Apachi AP921B2 Apachi AP921B3 Regular mounting base, 28mm High mounting base, 40mm High mounting base, 55mm Conventional manual call point with LED and transparent cover LPCB Ref. No. 512f/03
156
January 2009
SECTION 5: PART
Certificated Products MCP7B-RC01xx Indoor/Outdoor surface/flush mounting conventional call point Notes: 1) Sx (Surface mounted) Fx (Flush mounted) 2) xG (Glass element) xF (Flexible element) 3) The MCP3-7 Series manual call points LPCB Ref. No. 166b/43-166b/50 are approved with three micro-switches (Honeywell ZM10E50A01, Otehall 294/20/150/G and Burgess X4G310K1BBAQ) Outdoor surface mounting conventional waterproof call point Outdoor surface mounting conventional waterproof call point Outdoor surface mounting conventional waterproof call point Outdoor surface mounting conventional waterproof call point Notes: 1) xxx Sx indicates the series resistor value. 039Sx (lowest 39 ohms), 4K7Sx (highest 4.7 k ohms) 2) xxxSG (Glass element) xxxSF (Flexible element) 3) The WCP1-2 Series waterproof manual call points LPCB Ref. No.166b/51-166b/54 are approved with Honeywell micro switch ZW10F90AW1 Outdoor surface mounting conventional waterproof call point Outdoor surface mounting conventional waterproof call point Outdoor surface mounting addressable waterproof call point (System Sensor 500 series protocol) Outdoor surface mounting addressable waterproof call point (Honeywell 500 series protocol) Outdoor surface mounting conventional waterproof call point Outdoor surface mounting conventional waterproof call point Notes: 1) G (Glass element) F (Flexible element) 2) The WCP3-7 Series waterproof manual call points LPCB Ref. No. 166b/55-166b/62 are approved with Honeywell micro switch ZW10F90AW1 Indoor/Outdoor surface/flush mounting conventional call point Indoor/Outdoor surface/flush mounting conventional call point Indoor/Outdoor surface/flush mounting conventional call point Indoor/Outdoor surface/flush mounting conventional call point Notes: 1) xxxxx indicates the series resistor value. 039xx (lowest 39 ohms), 4K7xx (highest 4.7 k ohms) 2) xxxSx (Surface mounted) xxxFx (Flush mounted) 3) xxxxG (Glass element) xxxxF (Flexible element) 4) The MCP1-2 Series manual call points LPCB Ref. No. 166b/39-166b/42 are approved with three micro-switches (Honeywell ZM10E50A01, Otehall 294/20/150/G and Burgess X4G310K1BBAQ) Indoor/Outdoor surface/flush mounting conventional call point Indoor/Outdoor surface/flush mounting conventional call point Indoor/Outdoor surface/flush mounting conventional call point Indoor/Outdoor surface/flush mounting conventional call point Notes: 1) Sx (Surface mounted) Fx (Flush mounted) 2) xG (Glass element) xF (Flexible element) 3) The MCP3-7 Series manual call points LPCB Ref. No. 166b/43-166b/50 are approved with three micro-switches (Honeywell ZM10E50A01, Otehall 294/20/150/G and Burgess X4G310K1BBAQ) LPCB Ref. No. 166b/50
Accessories: (1) SR Surface mounting plastic box (1) SR1T Surface mounting plastic box c/w 1 terminal (1) SR2T Surface mounting plastic box c/w 2 terminal (1) SR3T Surface mounting plastic box c/w 3 terminal (1) SR4T Surface mounting plastic box c/w 4 terminal (1) MR Surface mounting metal box (1) ETT European Terminal Tray ETT 1, 2 & 3 (1) L Earth Continuity Link (1) BZR/1 Bazel Type 1 (1) BZR/2 Bazel Type 2 (1) BZR/3 Bazel Type 3 (1) M141 Spacer Piece (1) PTR Pattress PTR, PTRE, PTR2T, PTR2TE, PTR3T & PTR3TE (1) C Hinged Cover Note: 1) The above accessories are only supplied with MCP/WCP1-7 Series manual call points LPCB Ref. No. 166b/39-166b/62
January 2009
157
PART 3: SECTION 5
MANUAL CALL POINTS
World Series Manual Call points are approved with the following switch combinations: Otehall Otehall Otehall 382430 95/89S 382431 Honeywell V5T010TB3X144 Honeywell V5T020TBX145 Burgess XG3 Burgess GA43
WR2001 WR7/2001 WR2101 WR7/2101 WR2004 WR7/2004 WR2012 WR7/2012 WR2061 WR7/2061 WR2072 WR7/2072 WR3001 WR7/3001 WR3061 WR7/3061 WR3072 WR7/3072 WR3101 WR7/3101 WR3631
Certificate No: 166e to EN 54-11: 2001 and EN 54-17: 2005 Certificated Products MCP5A-RP02xx MCP5A-RP04xx Indoor/Outdoor surface/flush mounting addressable call point with short circuit isolator (System Sensor 500 series protocol) Indoor/Outdoor surface/flush mounting addressable call point with short circuit isolator (Honeywell 500 series protocol) Notes: 1) Sx (Surface mounted) Fx (Flush mounted) 2) xG (Glass element) xF (Flexible element) 3) The above manual call points are approved with three micro-switches (Honeywell ZM10E50A01, Otehall 294/20/150/G and Burgess X4G310K1BBAQ) Outdoor surface mounting addressable waterproof call point with short circuit isolator (System Sensor 500 series protocol) Outdoor surface mounting addressable waterproof call point with short circuit isolator (Honeywell 500 series protocol) Notes: 1) G (Glass element) F (Flexible element) 2) The above waterproof manual call points are approved with Honeywell microswitch ZW10F90AW1 LPCB Ref. No. 166e/01 166e/02
WCP5A-RP02Sx WCP5A-RP04Sx
166e/03 166e/04
Accessories: SR Surface mounting plastic box SR1T Surface mounting plastic box c/w 1 terminal SR2T Surface mounting plastic box c/w 2 terminal SR3T Surface mounting plastic box c/w 3 terminal SR4T Surface mounting plastic box c/w 4 terminal MR Surface mounting metal box ETT European Terminal Tray ETT 1, 2 & 3 L Earth Continuity Link BZR/1 Bazel Type 1 BZR/2 Bazel Type 2 BZR/3 Bazel Type 3 M141 Spacer Piece PTR Pattress PTR, PTRE, PTR2T, PTR2TE, PTR3T & PTR3TE C Hinged Cover
158
January 2009
SECTION 5: PART
Accessories: SR Surface mounting plastic box SR1T Surface mounting plastic box c/w 1 terminal SR2T Surface mounting plastic box c/w 2 terminal SR3T Surface mounting plastic box c/w 3 terminal SR4T Surface mounting plastic box c/w 4 terminal MR Surface mounting metal box ETT European Terminal Tray ETT 1, 2 & 3 L Earth Continuity Link BZR/1 Bazel Type 1 BZR/2 Bazel Type 2 BZR/3 Bazel Type 3 M141 Spacer Piece PTR Pattress PTR, PTRE, PTR2T, PTR2TE, PTR3T & PTR3TE C Hinged Cover
Notifier By Honeywell
Charles Avenue, Burgess Hill, West Sussex RH15 9UF UK Tel: +44 (0)1444 230300 Fax: +44 (0)1444 230888 E-mail: sales@notifiersystems.co.uk Website: www.notifierfiresystems.co.uk
Certificate No: 166e to EN 54-11: 2001 and EN 54-17: 2005 Certificated Products M700KAC/-xx Indoor/Outdoor surface/flush mounting addressable call point with short circuit isolator (System Sensor 500 series protocol) Notes: LPCB Ref. No. 166e/01
January 2009
159
PART 3: SECTION 5
MANUAL CALL POINTS
Certificated Products 1) Sx (Surface mounted) Fx (Flush mounted) 2) xG (Glass element) xF (Flexible element) 3) The above manual call point is approved with three micro-switches (Honeywell ZM10E50A01, Otehall 294/20/150/G and Burgess X4G310K1BBAQ) Accessories: SR Surface mounting plastic box SR1T Surface mounting plastic box c/w 1 terminal SR2T Surface mounting plastic box c/w 2 terminal SR3T Surface mounting plastic box c/w 3 terminal SR4T Surface mounting plastic box c/w 4 terminal MR Surface mounting metal box ETT European Terminal Tray ETT 1, 2 & 3 L Earth Continuity Link BZR/1 Bazel Type 1 BZR/2 Bazel Type 2 BZR/3 Bazel Type 3 M141 Spacer Piece PTR Pattress PTR, PTRE, PTR2T, PTR2TE, PTR3T & PTR3TE C Hinged Cover LPCB Ref. No.
Photain Controls
8 New Market Court, Chippenham Drive, Kingston, Milton Keynes BN18 0BE UK Tel: 01908 281981 Fax: 01908 282554 E-mail: john.davies@ge.com
Certificate No: 092r to EN 54-11: 2001 Certificated Products BGU12000LED Analogue addressable manual call point LPCB Ref. No. 092r/01
160
January 2009
SECTION 5: PART
Certificated Products Series 01 Conventional Type A re-settable indoor flush/surface mounted manual call point Notes: 1) Surface mount approved model RP-RF-01. 2) Flush mount approved model RP-RS-01. 3) Approved colour red only. LPCB Ref. No. 653a/01
Sareme UAB
Naugarduko str. 32/2, Vilnius LT2006, Lithuania Tel: +3705 2135047 Fax: +3705 2333567 E-mail: sareme@sareme.lt
Certificate No: 512f to EN 54-11:2001 + A1:2005 Certificated Products SF MCP127 SF MCP127-F SF MCP127-TC SF MCP127-FTC Conventional manual call point with LED Conventional manual call point with flashy LED Conventional manual call point with LED and transparent cover Conventional manual call point with flashy LED and transparent cover LPCB Ref. No. 512f/01 512f/02 512f/03 512f/04
Accessories SF MCP127-B1 Regular mounting base, 28mm SF MCP127-B2 High mounting base, 40mm SF MCP127-B3 High mounting base, 55m
Certificated Products DM1154 Ex DM1101 MT320C Addressable interactive manual call point Conventional indoor/outdoor manual call point Conventional indoor/outdoor manual call point
January 2009
161
PART 3: SECTION 5
MANUAL CALL POINTS
Certificated Products DM1131 DM1151 DM1104 DM1134 DM1154 DM1104H DM1134H DM1154H DM1154H-Ex MT320C DM1101 FDM225-RP FDM225-RG FDM226-RP FDM226-RG FDM224 FDM224H FDM221 FDM223 FDM223H FDM225 RP (F) FDM225-RG (F) FDM1101-RG FDM1101-RP FDM1101A-RG FDM1101A-RP FDM1101-RG(F) FDM1101-RP(F) Analogue addressable indoor/outdoor manual call point. Interactive indoor/outdoor manual call point Conventional indoor and outdoor manual call point Addressable indoor and outdoor manual call point Interactive indoor and outdoor manual call point Conventional indoor and outdoor manual call point (DMZ1197-AC) Analogue addressable indoor and outdoor manual call point (DMZ1197-AC) Interactive indoor and outdoor manual call point (DMZ1197-AC) Addressable interactive manual call point (DMZ1197-AC) Indoor manual call point, flush mounted (DMZ1191 mounting box) Digital addressable Type A indoor/outdoor manual call point with resettable plastic element (FDMH295-R and FDMH295-S Digital addressable Type A indoor/outdoor manual call point with resettable glass element (FDMH295-R and FDMH295-S Digital addressable Type A indoor/outdoor manual call point with resettable plastic element (including housing base) Digital addressable Type A indoor/outdoor manual call point with resettable plastic element (including housing base) Digital addressable Type A indoor/outdoor manual call point with resettable glass element and incorporating short circuit isolator and DMZ1195) Digital addressable Type A indoor/outdoor manual call point with resettable glass element and incorporating short circuit isolator and DMZ1197-AD) Digital addressable Type A indoor/outdoor manual call point with resettable glass element and incorporating short circuit isolator and FDMK291) Digital addressable Type B indoor/outdoor manual call point with resettable glass element and incorporating short circuit isolator and DMZ1195) Digital addressable Type B indoor/outdoor manual call point with resettable glass element and incorporating short circuit isolator (DMZ1197-AC) Digital addressable Type A indoor/outdoor manual call point with re-settable plastic element; French labelling on re-settable plastic element (FDMH295-R and FDMH295-S) Digital addressable Type A indoor/outdoor manual call point with non-resettable glass element; French labelling on non-resettable glass element (FDMH295-R and FDMH295S) Collective Type A Indoor / Outdoor Manual Call Point with Non-Resettable Glass Element Collective Type A Indoor / Outdoor Manual Call Point with Resettable Plastic Element. Conventional Type A Indoor / Outdoor Manual Call Point with Non-Resettable Glass Element. Conventional Type A Indoor / Outdoor Manual Call Point with Resettable Plastic Element. Collective Type A Indoor / Outdoor Manual Call Point with Non-Resettable Glass Element. Collective Type A Indoor / Outdoor Manual Call Point with Resettable Plastic Element; French labelling on Resettable Plastic Element. LPCB Ref. No. 126w/04 126w/05 126w/06 126w/07 126w/08 126w/09 126w/10 126w/11 126w/12 166b/07 166b/11 126ap/01 126ap/02 126ap/03 126ap/04 126ap/05 126ap/06 126ap/07 126ap/08 126ap/09 126ap/10 126ap/11 126as/01 126as/02 126as/03 126as/04 126as/05 126as/06
Accessories: FDMC291 protective cover FDMK291 key with cover DMZ1197-AC protective cover DMZ1195 key FDMH295-R Housing base FDMH295-S Housing base with holes and sockets
162
January 2009
SECTION 5: PART
Certificated Products 3) The manual call point is approved with three micro-switches (Honeywell ZM10E50A01, Otehall 294/20/150/G and Burgess X4G310K1BBAQ) Outdoor surface mounting addressable call point (Advanced System Sensor protocol) Notes: 1) G element) F (Flexible element) 2) The manual call point is approved with Honeywell micro switch ZW10F90AW1 Indoor surface/flush mounting addressable call point with short circuit isolator (Advanced System Sensor protocol) Notes: 1) S x (Surface mounted) F x (Flush mounted) 2) x G (Glass element) x F (Flexible element) 3) The manual call point is approved with three micro-switches (Honeywell ZM10E50A01, Otehall 294/20/150/G and Burgess X4G310K1BBAQ) Outdoor surface mounting addressable call point with short circuit isolator (Advanced System Sensor protocol) Notes: 1) G element) F (Flexible element) 2) The manual call point is approved with Honeywell micro switch ZW10F90AW1 LPCB Ref. No. 166b/64
WCP5A-RP11Sx
MCP5A-RP12xx
166e/05
WCP5A-RP12Sx
166e/06
January 2009
163
PART 3: SECTION 6
LINE UNITS A Line Unit is the term given to define devices used for functions other than fire detection, which are connected to a fire detection and alarm system transmission path or within other components of the fire detection and alarm system e.g. inside Control and Indicating Equipment. For example, the following devices may be regarded as Line Units: short circuit isolators input/output interfaces
Short-circuit isolators are used to limit the consequences of low parallel resistance faults between the lines of a transmission path of a fire detection and fire alarm system. The transmission path is normally in a loop configuration which is separated into sections by the short circuit isolators, such that a detected fault in a particular section will isolate that particular section allowing other components in other sections on the loop to function correctly. Input/output devices are intended for different applications, and may therefore have different functions. Their functions are specified by the manufacturer and they are tested and approved against this specification. This section lists approved Line Units which are connected to a fire detection and alarm system. The initial approval and continued approval processes for Line Units are outlined in scheme document SD038. Products listed in this section have been approved to: EN 54-17:2005 Short-circuit isolators EN 54-18:2005 Input/output devices
Audit: Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Notes: 1. It is recommended that short circuit isolators and input/output devices are certificated to EN 54-17:2006 and EN 54-18 respectively. EN 54-17:2006 and EN 54-18:2006 are now harmonised standards for the Construction Products Directive and CE marking is required for most of the European market by 1 December 2008. It is therefore recommended that devices are certificated to EN 54-17:2006 or EN 54-18:2006 where applicable as soon as possible. 2. Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.
164
January 2009
SECTION 6: PART
LINE UNITS
Sales Enquiries Spain, Apollo Espana Tel: +34 627 988 061 Fax: +34 949 335 289 E-mail: apollo.espana@apollo-fire.com
Sales Enquiries China, Apollo Fire Detectors Limited,, Shanghai representative office Tel: +86 21 5237 0922 Fax: +86 21 5237 0920 E-mail: tony.ye@apollo-fire.com
010e to LPCB test schedule 62449/1.3 010f to EFSG/F/95/007 010k to CEA GEI 1-052:Draft 2: 1997 010aa to EN 54-17:2005 LPCB Ref. No. 010k/04 010k/03 010e/01 010k/01 010k/02 010k/05 010k/05 010k/06 010k/06 010k/10 010k/10 010k/07 010k/07 010k/08 010k/08 010k/09 010k/09 010f/01
Certificated Products 45681-321 XP95 45681-323 XP95 55000-700 XP95 55000-710 XP95 55000-720 XP95 55000-840 XP95 55000-841 XP95 55000-842 XP95 55000-843 XP95 55000-844 XP95 55000-845 XP95 55000-846 XP95 55000-847 XP95 55000-848 XP95 55000-849 XP95 55000-851 XP95 55000-852 XP95 55000-855 XP95 Negative short circuit isolating base Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Positive short circuit isolating base Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Short circuit isolator (45681-211 mounting base) Positive short circuit isolator (45681-211 mounting base) Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Negative short circuit isolator (45681-211 mounting base) Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable switch monitor plus with isolator -flush mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable switch monitor plus with isolator -surface mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable switch monitor with isolator -flush mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable switch monitor with isolator -surface mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable Zone monitor unit with isolator -flush mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable zone monitor unit with isolator -surface mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable input/output unit with isolator flush mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable input/output unit with isolator -surface mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable output unit with isolator flush mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable output unit with isolator -surface mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable sounder controller unit with isolator -flush mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable sounder controller unit with isolator -surface mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Single Channel Protocol Translator
January 2009
165
PART 3: SECTION 6
LINE UNITS
Certificated Products 55000-856 XP95 55000-588 XP95 55000-589 XP95 45681-284 Bases: 45681-211 XP95 isolator base Dual Channel Protocol Translator Analogue addressable 3 Channel Input/Output unit with short circuit isolator Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable 3 Channel Input/Output unit Approved with Apollo Series 90, XP95 and Discovery digital communication protocols XP95/Discovery short circuit isolating base LPCB Ref. No. 010f/02 010k/11 010k/12 010aa/01
166
January 2009
SECTION 6: PART
LINE UNITS
Certificate No: 092j to GEI 1-052: Draft 2 Certificated Products ZP760-2 A60E-2 Short circuit isolator (ZP760-SB mounting base) Analogue addressable line isolator module LPCB Ref. No. 092j/01 092j/02
Certificate No: 092q to CEA GEI 1-084 - 08/08/2000 Draft Certificated Products A45E-2 A50E-2 Analogue addressable single input interface module Analogue addressable line relay module LPCB Ref. No. 092q/01 092q/02
GE Security Inc
5 North Main Street, Pittsfield, ME 04967, USA Tel: +1 207 487 3104 Fax: +1 207 487 5526 E-mail: leon.newsome@ge.com Website: www.gesecurity.com European Sales: Rudford Estate, Ford Aerodrome, Arundel, West Sussex BN18 0BE UK Tel: +44 (0)1903 711 440 Fax: +44 (0)1903 711 448 E-mail: info@estinternational.com
Certificate No: 262d to EFSG/F/95/007 Approved Products SIGA-CC1 SIGA-CC2 SIGA-CT1I SIGA-CT2I Single input signal module Note: Approved using personality code 5 Dual input signal module Note: Approved using personality code 7 Single input module Note: Approved using personality codes 3, 4 and 18 Dual input module Note: Approved using personality codes 3, 4 and 18 LPCB Ref. No. 262d/01 262d/02 262d/03 262d/04
Certificate No: 92j to GEI 1-052:Draft 2.0 (11-06-97) Certificated Products EA760-2 Short circuit isolator (EA760-SB mounting base) LPCB Ref. No. 092j/01
January 2009
167
PART 3: SECTION 6
LINE UNITS
Gent By Honeywell
140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN UK Tel: +44 (0)116 246 2000 Fax: +44 (0)116 246 2300 E-mail: gent_enquiry@gent.co.uk Website: www.gent.co.uk Middle East Sales Enquiries E-mail: gent.export@honeywell.com
Certificate No: 42b to CEA GEI 1-084: 08-08-2000 Approved Products 808610 808611 808613 808614 12 Relay transponder 32 LED output transponder 4 Detection zones/2 relay output transponder 1 Detection zone transponder LPCB Ref. No. 400b/01 400b/02 400b/03 400b/04
Certificate No: 042ap to prEN 54-18: 2005 Certificated Products 34410 34450 34415 Analogue addressable zone module (loop powered) Analogue addressable four channel interface module (loop powered) Analogue addressable single channel interface module (loop powered) LPCB Ref. No. 042ap/01 042ap/02 042ap/03
Certificate No: 042ba to EN 54-17: 2005 & EN 54-18: 2005 Certificated Products S4-34410 S4-34411 S4-34415 S4-34420 S4-34450 Analogue addressable 1 input interface module with short circuit isolator, low voltage. (S4-34490 and S4-34492 boxes) Analogue addressable 1 output DIN rail mounting interface module with short circuit isolator, medium voltage. Analogue addressable 1 output surface mounting interface module with short circuit isolator, medium voltage. Analogue addressable 1 input and 1 output interface module with short circuit isolator, low voltage. (S4-34490 and S4-34492 boxes) Analogue addressable 4 input / output interface module with short circuit isolator, low voltage. (S4-34490 and S4-34492 boxes) LPCB Ref. No. 042ba/01 042ba/02 042ba/03 042ba/04 042ba/05
168
January 2009
SECTION 6: PART
Certificated Products I-9300 I-9301 C-9503 Analogue addressable input module Analogue addressable single input/output module Loop isolator LPCB Ref. No. 548h/01 548h/02 548f/01
LINE UNITS
Gulf Security Technology Co. Ltd (Manufacturing Division of Global System Technology PLC)
No. 80 Changjiang East Road, Economic & Technological Development Zone, Qinhuangdao, Hebei Province 066004, Peoples Republic of China Tel: +86 0335 8502528 Fax: +86 0335 8508942 E-mail: gst@gst.com.cn Website: www.gst.com.cn
Certificate No: 548h to CEA GEI 1-084: 08.08.2000 Certificate No: 548f to CEA GEI 1-052 - Draft 2.0 Certificated Products GST-LD-8300 GST-LD-8301 GST-LD-8322 Analogue addressable input module Analogue addressable single input/output module Loop isolator LPCB Ref. No. 548h/01 548h/02 548f/01
HDR
Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA UK Tel: +44 (0)1634 260133 Fax: +44 (0)1634 260132 E-mail: info@hochikieurope.com Website: www.hochikieurope.com
Certificate No: 164b to EFSG/F/95/007 Certificate No: 164d to CEA 1-052 Draft 2.0: 11/06/97 Certificate No: 164f to GEI-CEA-1-084 Certificated Products 1433020 1433080 1433120 1433040 1433100 1226110 1433190 Dual Sounder Controller Mini Zone Monitor Dual Relay Controller Dual Switch Monitor Dual Zone Monitor Short Circuit Isolator Base Input/Output Module LPCB Ref. No. 164b/01 164b/02 164b/03 164b/04 164b/05 164d/01 164f/01
January 2009
169
PART 3: SECTION 6
LINE UNITS
Certificate No: 199q to CEA GEI 1-052 Draft 2.0,CEA GEI 1-084 Draft (08-08-00) & prEN 54-17 Draft (July 2002) Certificated Products MI-DMMI MI-DMM2I MI-D2ICMO MI-DCMO MI-D240MO Analogue addressable single channel input module with short circuit isolator Analogue addressable dual channel input module with short circuit isolator Analogue addressable dual channel input and single channel output module with short circuit isolator Single channel output module with short circuit isolator Single channel 240V output module with short circuit isolator LPCB Ref. No. 199q/01 199q/02 199q/03 199q/04 199q/05
170
January 2009
SECTION 6: PART
Certificated Products MI-D240CMO-DIN MI-DC2M Single channel 240V output module, DIN rail mount with short circuit isolator Analogue addressable conventional zone interface module LPCB Ref. No. 199q/06 199q/07
LINE UNITS
Certificate No: 199r to CEA GEI 1-052 Draft 2.0: 11.06.97 & prEN 54-17 Draft: July 2002 Certificated Products MI-DISO Short circuit isolator module LPCB Ref. No. 199r/01
Certificate No: 010aa to EN 54-17:2005 Certificated Products NV-IA-IB Short circuit isolating base LPCB Ref. No. 010aa/01
January 2009
171
PART 3: SECTION 6
LINE UNITS
Notifier By Honeywell
Charles Avenue, Burgess Hill, West Sussex RH15 9UF UK Tel: +44 (0)1444 230300 Fax: +44 (0)1444 230888 E-mail: sales@notifiersystems.co.uk Website: www.notifierfiresystems.co.uk
Certificate No: 199d to EFSG/F/92/009 Approved Products MMX-1E CMX-2E MMX-101E ISO-XE Monitor module Control module Mini monitor module Short circuit isolator LPCB Ref. No. 199d/01 199d/02 199d/04 199d/03
Certificate No: 199q to CEA GEI 1-052 Draft 2.0, CEA GEI 1-084 Draft (08-08-00) and prEN 54-17 Draft (July 2002) Certificated Products M710 M720 M721 M701 M701-240 M701-240-DIN M710-CZ Analogue addressable single channel input module with short circuit isolator Analogue addressable dual channel input module with short circuit isolator Analogue addressable dual channel input and single channel output module with short circuit isolator Single channel output module with short circuit isolator Single channel 240V output module with short circuit isolator Single channel 240V output module, DIN rail mount with short circuit isolator Analogue addressable conventional zone interface module LPCB Ref. No. 199q/01 199q/02 199q/03 199q/04 199q/05 199q/06 199q/07
Certificate No: 199r to CEA GEI 1-052 Draft 2.0: 11.06.97 & prEN 54-17 Draft: July 2002 Certificated Products M700X Short circuit isolator module LPCB Ref. No. 199r/01
Novar GmbH
Security and Building Management Systems, Dieseltrasse 2, D-41469, Neuss, Germany Tel: +49 (0)2137 170 Fax: +49 (0)2137 17286 E-mail: info@esser-systems.de Website: www.esser-systems.de
Certificate No: 400b to CEA GEI 1-084 Approved Products 808610 808611 808613 808614 12 Relay transponder 32 LED output transponder 4 Detection zones/2 relay output transponder 1 Detection zone transponder LPCB Ref. No. 400b/01 400b/02 400b/03 400b/04
172
January 2009
SECTION 6: PART
LINE UNITS
Certificate No: Certificate No: Certificate No: Certificate No: Certificate No:
199j to CEA GEI 1-052 Draft 2.0 199e to EFSG/F/95/007 199r to CEA GEI 1-052 Draft 2.0 (11-06-97) and prEN 54-17 Draft (July 2002) 199q to CEA GEI 1-052 Draft 2.0, CEA GEI 1-084 Draft (08-08-00) and prEN 54-17 Draft (July 2002) 199d to EFSG/F192/009 LPCB Ref. No. 199d/01 199d/02 199d/03 199d/04 199e/01 199r/01 199q/01 199q/02 199q/03 199q/04 199q/05 199q/06 199j/02 199j/03 199q/07
Certificated Products M500ME M500CHE M500XE M501ME M503ME M200XE M210E M220E M221E M201E M201E-240 M201E-240-DIN B524IEFT-1 ISO524-1 M210E-CZ Monitor module Control module Short circuit isolator Mini monitor module Micromonitor module Short circuit isolator module Analogue addressable single channel input module with short circuit isolator Analogue addressable dual channel input module with short circuit isolator Analogue addressable dual channel input and single channel output module with short circuit isolator Single channel output module with short circuit isolator Single channel 240V output module with short circuit isolator Single channel 240V output module, DIN rail mount with short circuit isolator Short circuit isolator base Short circuit isolator module Analogue addressable conventional zone interface module
January 2009
173
PART 3: SECTION 6
LINE UNITS
UK Sales: Tel: +44 (0)1189 783703 Fax: +44 (0)1189 775750 Website: www.sibt.com/www.uk.cerberus.com
126j to EFSG/F/94/002 126m to EFSG/F/95/007 126p to CEA GEI 1-052 Draft 2 126t to CEA GEI 1-052 Draft 2 LPCB Ref. No. 126m/01 126m/02 126m/03 126m/04 126j/01 126j/02 126p/01 126p/02 126p/03 126p/04 126p/05 126p/06 126p/01 126p/02 126p/03 126t/02
Approved Products DC1131 DC1134 DC1157 DC1192 DC1151 DC1154 DC1131-AA DC1134-AA DC1136-AA DC1154-AA DC1156-AA DC1157-AA EB322A AB322A ABI322A CB320A Input module Output module Input module Input/output module Input module Output module Input module Output module Output module Output module Output module Input module Input module Output module Output module Input module
Certificate No: 126ae to CEA GEI 1-052: Draft 2.0, 11/06/97 Certificated Products FDCL221 Accessories: TS35 standard top hat rail Analogue addressable line separator LPCB Ref. No. 126ae/01
Certificate No: 126ad to CEA GEI 1-084 : 08/08/00 and CEA GEI 1-052: Draft 2.0, 11/06/97 Certificated Products FDCI222 FDCIO222 Accessories: FDCM291 mounting foot TS35 standard top hat rail Analogue addressable input module (FDCM291) Analogue addressable input/output module (FDCM291) LPCB Ref. No. 126ad/01 126ad/02
174
January 2009
SECTION 6: PART
LINE UNITS
Certificate No: 126aq to EN 54-17:2005 and EN 54-18:2005 Certificated Products FDCIO223 Addressable transponder incorporating short circuit isolators Note: 1) Approved when used in conjunction with housing box FDCH292 LPCB Ref. No. 126aq/01
January 2009
175
PART 3: SECTION 7
SOUNDERS The purpose of a fire alarm sounder is to warn person(s) within, or in the vicinity of, a building of the occurrence of a fire emergency situation in order to enable such person(s) to take appropriate measures. Fire alarm sounders can be of different construction and may have different frequency ranges, temporal patterns and output levels. Guidance on the type, frequency, temporal pattern, and output levels should be sought from the applicable installation rule or code of practice (e.g. BS 5839-1). For example BS 5839-1 recommends sounders with continuous output and frequency range between 500 Hz to 1 000 Hz. Fire alarm sounders may be used for other type of risk or non-fire emergency alarm. In this case it is always recommended that a different temporal pattern, frequency signal from the fire signal is selected to avoid confusion. This section lists sounders approved for use indoors and outdoors in fire detection and fire alarm systems. The initial approval and continued approval processes for line units are outlined in scheme document SD039. Products listed in this section have been approved to: EN 54-3:2001 Sounders EN 54-3:2001 + A1:2002 + A2:2006 Sounders
Audit: Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Notes: 1. EN 54-3:2001 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 30 June 2005. It is therefore recommended that sounders are certificated to EN 54-3: 2001. 2. Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.
Wireless Sounders
Certificated Products XPA-SO-14001-APO Xpander addressable sounder (Red ) (XPA-SB-10023-APO mounting base) Notes: 1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 13 2) The complete radio base/sounder combination is available as Apollo Part No.: XPA-CB-14001-APO 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells 4) The radio link functionality is not included within the scope of approval. Xpander addressable sounder (White) (XPA-SB-10024-APO mounting base) Notes: 1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 13 2) The complete radio base/sounder combination is available as Apollo Part No.: LPCB Ref. No. 010af/01
XPA-SO-14002-APO
010af/02
176
January 2009
SECTION 7: PART
Certificated Products XPA-CB-14002-APO 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells 4) The radio link functionality is not included within the scope of approval. Xpander addressable sounder strobe (Red head / red lens) (XPA-SB-10023-APO mounting base) Notes: 1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 13 2) The complete radio base/sounder combination is available as Apollo Part No.: XPA-CB-14003-APO 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells 4) The radio link functionality is not included within the scope of approval. Xpander addressable sounder beacon (Red head / amber lens) (XPA-SB-10024-APO mounting base) Notes: 1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 13 2) The complete radio base/sounder combination is available as Apollo Part No.: XPA-CB-14004-APO 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells 4) The radio link functionality is not included within the scope of approval. Xpander addressable sounder beacon (White head / clear lens) (XPA-SB-10024-APO mounting base) Notes: 1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 13 2) The complete radio base/sounder combination is available as Apollo Part No.: XPA-CB-14005-APO 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells 4) The radio link functionality is not included within the scope of approval. LPCB Ref. No.
SOUNDERS
XPA-SN-14003-APO
010af/03
XPA-SN-14004-APO
010af/04
XPA-SN-14005-APO
010af/05
Bases: XPA-SB-10023-APO Radio link mounting base - red XPA-SB-10024-APO Radio link mounting base - white
January 2009
177
PART 3: SECTION 7
SOUNDERS
Certificated Products 13) - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14) - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15) - Sweet 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16) - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17) - ISO8201 : 970 Hz : 500 ms 18) - ISO8201 : 2850 Hz : 500 ms 19) - 800 Hz : 250 ms / 970 Hz : 250 ms 20) - 2850 Hz Continuous 21) - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22) - 800 Hz : 500 ms / 970 Hz : 500 ms 23) - 2850 Hz : 500 ms / Off : 500 ms 24) - 925 Hz : 250 ms / Off : 1000 ms 25) - 970 Hz Continuous 26) - 660 Hz : 1800 ms / Off: 1800 ms 27) - 660 Hz : 6500 ms / Off : 13000 ms 28) - 660 Hz Continuous 29) - 554 Hz : 500 ms / 440 Hz : 500 ms 30) - 660 Hz : 500 ms / Off : 500 ms 31) - 2850 Hz : 150 ms / Off : 100 ms 32) - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33) - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34) - 988 Hz : 250 ms / 645 Hz : 250 ms 35) - 510 Hz : 250 ms / 610 Hz : 250 ms 36) - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37) - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38) - 845 Hz Continuous 39) - 970 Hz : 1000 ms / Off : 1000 ms 40) - 800 Hz : 150 ms / 970 Hz : 150 ms 41) - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42) - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43) - 2850 Hz : 1000 ms / Off : 1000 ms 44) - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45) - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46) - 440 Hz : 600 ms / Off : 600 ms 47) - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48) - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49) - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50) - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51) - Whoop 500-1200 3.5s/0.5s Bases YBN -R/3 base YBO-R/SCI isolator base LPCB Ref. No.
Certificate No: 715a-(cl-2) to EN54-3:2001 Certificated Products Banshee MT Sounder (892 shallow base version and 893 deep base version) 1. Certified to EN 54-3: 2001 with the following tones: Sound 2 Banshee LF Sound 143 Banshee HF (and Bedlam) Sound 19 Slow Whoop (Dutch) Sound 20 DIN Klung (German) 2. Approved as Type A when used with shallow base (892) & Type B when used with deep base (B93). 3. Approved voltage range 10-28V. Bases 892 shallow base 893 deep base LPCB Ref. No. 715a/01
178
January 2009
SECTION 7: PART
SOUNDERS
VTG-32E-DB
546a/01
VPR-DT
546a/02
VSO-32
546a/04
VSO-4
546a/03
VSO-3
546a/05
January 2009
179
PART 3: SECTION 7
SOUNDERS
Detectomat GmbH
An Der Strusbek 5, D-22926 Ahrensburg, Hamburg, Germany Tel: +49 4102 2114 636 Fax: +49 4102 2114 670 E-mail: approval@detectomat.com
Certificate No: 546a to EN 54-3: 2001 + A1: 2002 Certificated Products Verso 4 32216 Conventional Indoor Type A sounder base Notes: 1) This sounder meets the requirements of EN 54-3 : 2001 for the following tones at low, medium and high volume settings: 1 - LF Sweep (800-1000Hz continuous 11 - Dutch Sweep Tone (970Hz Continuous) 25 - German DIN tone (Sweep 1200-500Hz @ 1Hz) 2) Cover plate (part no. 116-009) must be used LPCB Ref. No. 546a/05
XP-172-001
786f/02
XP-173-002
786f/03
180
January 2009
SECTION 7: PART
Certificated Products base) Notes: 1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 13 2) The complete radio base/sounder combination is available as EMS Part No.: XP-310-022 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells 4) The radio link functionality is not included within the scope of approval Fire-Cell addressable sounder beacon (Red head / amber lens) (XP-171-001 and XP171-002 mounting bases) Notes: 1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 13 2) The complete radio base/sounder combination is available as EMS Part No.: XP-310-032 XP-310-031 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells 4) The radio link functionality is not included within the scope of approval Fire-Cell addressable sounder beacon (Red head / clear lens) (XP-171-001 and XP-171002 mounting bases) Notes: 1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 13 2) The complete radio base/sounder combination is available as EMS Part No.: XP-310-012 XP-310-011 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells 4) The radio link functionality is not included within the scope of approval LPCB Ref. No.
SOUNDERS
XP-173-003
786f/04
XP-173-004
786f/05
Bases: XP-171-001 Radio link mounting base - white XP-171-002 Radio link mounting base - red
January 2009
181
PART 3: SECTION 7
SOUNDERS
Fulleon Limited
Llantarnam Park, Cwmbran, Gwent NP44 3AW UK Tel: +44 (0)1633 628500 Fax: +44 (0)1633 866346 E-mail: sales@fulleon.co.uk Website: www.fulleon.com
Certificate No: 378b to EN 54: Part 3: 2001 Approved Products ROLP Roshni LP Sounder Notes: 1The sounder is approved in red and white colours. 2Using Deep, U-shaped, and shallow sounder bases in red and white colours. 3Meets the requirements of EN 54-3 at tone patterns 3 and 8 only. LPCB Ref. No. 378b/01
Gent By Honeywell
140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN UK Tel: +44 (0)116 246 2000 Fax: +44 (0)116 246 2300 E-mail: gent_enquiry@gent.co.uk Website: www.gent.co.uk
Certificate No: 042ah to EN 54-3: 2001 Certificate No: 042ar to EN 54-3: 2001 +A1 , CEA GEI 1-052- Draft 2.0 11-06-97 Certificated Products S3-SN-R S3-SN-W S3IP-SN-R S3IP-SN-W S2IP-SN-R S2IP-SN-W S2IP-SN-R3 S2IP-SN-W3 S3-SN-ST-RR S3-SN-ST-WR S3IP-SN-ST-RR S3IP-SN-ST-WR S3IP-SN-ST-RW S31P-SN-ST-WA S3-VO-R S3-VO-W S3IP-VO-R S3IP-VO-W S2IP-VO-R S2IP-VO-W S3-VO-ST-RR S3-VO-ST-WR S3IP-VO-ST-RR S3IP-VO-ST-WR S3-SN-R S3-SN-W S3IP-SN-R S3IP-SN-W S2IP-SN-R S2IP-SN-W S2IP-SN-R3 Red LP Indoor Analogue Addressable Sounder White LP Indoor Analogue Addressable Sounder Red Outdoor Analogue Addressable Sounder White Outdoor Analogue Addressable System Sounder Red Outdoor Analogue Addressable System Sounder White Outdoor Analogue Addressable System Sounder 3 Way Red Outdoor Analogue Addressable System Sounder 3 Way White LP Outdoor Analogue Addressable Sounder/Strobe Red Lens Red LP Indoor Analogue Addressable Sounder/Strobe Red Lens White LP Indoor Analogue Addressable Sounder/Strobe Red Lens Red Outdoor Analogue Addressable Sounder/Strobe Red Lens White Outdoor LP Analogue Addressable Sounder/Strobe Red Lens Red Outdoor Analogue Addressable Sounder/Strobe 2 Way White Lens White Outdoor Analogue Addressable Sounder/Strobe 2 Way Amber Lens Red LP Indoor Voice Analogue Addressable Sounder White LP Indoor Voice Analogue Addressable Sounder Red LP Outdoor Voice Analogue Addressable Sounder White LP Outdoor Voice Analogue Addressable Sounder Red Outdoor Voice Analogue Addressable Sounder White Outdoor Voice Analogue Addressable Sounder Red LP Indoor Voice Analogue Addressable Sounder/Strobe Red Lens White LP Indoor Voice Analogue Addressable Sounder/Strobe Red Lens Red Outdoor Voice Analogue Addressable Sounder/Strobe Red Lens White LP Outdoor Voice Analogue Addressable Sounder/Strobe Red Lens Analogue Addressable Red LP Indoor Sounder with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable White LP Indoor Sounder with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable Red Outdoor Sounder with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable White Outdoor System Sounder with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable Red Outdoor System Sounder with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable White Outdoor System Sounder 3 Way with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable Red Outdoor System /Sounder 3 Way with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone LPCB Ref. No. 042ah/01 042ah/02 042ah/03 042ah/04 042ah/05 042ah/06 042ah/07 042ah/08 042ah/09 042ah/10 042ah/11 042ah/12 042ah/13 042ah/14 042ah/15 042ah/16 042ah/17 042ah/18 042ah/19 042ah/20 042ah/21 042ah/22 042ah/23 042ah/24 042ar/01 042ar/02 042ar/03 042ar/04 042ar/05 042ar/06 042ar/07
182
January 2009
SECTION 7: PART
Certificated Products S2IP-SN-W3 S3-SN-ST-RR S3-SN-ST-WR S3IP-SN-ST-RR S3IP-SN-ST-WR S3IP-SN-ST-RW S3IP-SN-ST-WA Analogue Addressable White LP Outdoor Sounder/Strobe Red Lens with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable Red LP Indoor Sounder/Strobe Red Lens with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable White LP Indoor Sounder/Strobe Red Lens with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable Red Outdoor Sounder/Strobe Red Lens with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable White Outdoor LP Sounder/Strobe Red Lens with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable Red Outdoor Sounder/Strobe 2 Way White Lens with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable White Outdoor Sounder / Strobe 2 Way Amber Lens with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone LPCB Ref. No. 042ar/08 042ar/09 042ar/10 042ar/11 042ar/12 042ar/13 042ar/14
SOUNDERS
January 2009
183
PART 3: SECTION 7
SOUNDERS
Gulf Security Technology Co. Ltd (Manufacturing Division of Global System Technology PLC)
No. 80 Changjiang East Road, Economic & Technological Development Zone, Qinhuangdao, Hebei Province 066004, Peoples Republic of China Tel: +86 0335 8502528 Fax: +86 0335 8508942 E-mail: gst@gst.com.cn Website: www.gst.com.cn
Certificate No: 548e to EN 54-3:2001 Certificated Products GST-HX-F8502 GST-HX-M8502 Conventional sounder strobe Notes: Meets the requirements of EN 54-3: 2001 at the following tones: Fixed tone: 1.35Hz (400ms on / 340ms off) Intelligent sounder strobe Notes: Meets the requirements of EN 54-3: 2001 at the following tones: Mode I (for pre alarm): 0.61Hz (430ms on / 1200ms off) Mode II (for fire alarm): 1.30Hz (430ms on / 340ms off) LPCB Ref. No. 548e/01 548e/02
HDR
Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA UK Tel: +44 (0)1634 260133 Fax: +44 (0)1634 260132 E-mail: info@hochikieurope.com Website: www.hochikieurope.com
Certificate No: 164h to EN 54 3: 2001 Certificated Products 1460040 Loop Powered Base Sounder (1426010 and 1226110 bases) Notes: 1) Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms LPCB Ref. No. 164h/01
184
January 2009
SECTION 7: PART
Certificated Products 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Loop Powered Sounder/Base (1426010 and 1226110 bases) Notes 1) The beacon function of this device is not included in the scope of this approval 2) Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous LPCB Ref. No.
SOUNDERS
1460070
164h/03
January 2009
185
PART 3: SECTION 7
SOUNDERS
Certificated Products 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Loop Powered Sounder Wall Sounder (1426010 and 1226110 bases) Notes: 1) Meets the requirements of EN 54-3 at the following tones: H1 - 925/628 at 2Hz H4 - French 554: 100ms / 440: 400ms H5 - Swedish 660: 150ms / Off: 150ms 8 - Whoop 500-1200 3s/0.5s 12 - Sweep 800/970 at 1Hz 15 - Sweep 2400-2850 at 1Hz 17 - 970:ISO8201 0.5s 18 - 2850:ISO820 0.5s LPCB Ref. No.
1460050
164h/02
186
January 2009
SECTION 7: PART
Certificated Products 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Loop powered base sounder white version (YBN-R/3 and YBO-R/SCI bases) Note: 1) Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms LPCB Ref. No.
SOUNDERS
YBO-BS(WHT)
164h/01
January 2009
187
PART 3: SECTION 7
SOUNDERS
Certificated Products 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Loop powered wall sounder (YBN-R/3 and YBO-R/SCI bases) Note: 1) Meets the requirements of EN 54-3 at the following tones: H1 - 925/628 at 2Hz H4 - French 554: 100ms / 440: 400ms H5 - Swedish 660: 150ms / Off: 150ms 8 - Whoop 500-1200 3s/0.5s 12 - Sweep 800/970 at 1Hz 15 - Sweep 2400-2850 at 1Hz 17 - 970:ISO8201 0.5s 18 - 2850:ISO820 0.5s Loop powered wall sounder - white version (YBN-R/3 and YBO-R/SCI bases) Note: 1) Meets the requirements of EN 54-3 at the following tones: H1 - 925/628 at 2Hz H4 - French 554: 100ms / 440: 400ms H5 - Swedish 660: 150ms / Off: 150ms 8 - Whoop 500-1200 3s/0.5s 12 - Sweep 800/970 at 1Hz 15 - Sweep 2400-2850 at 1Hz 17 - 970:ISO8201 0.5s 18 - 2850:ISO820 0.5s Loop powered wall sounder - weatherproof version (YBN-R/3, YBO-R/SCI and WS2WPK base) Note: 1) Meets the requirements of EN 54-3 at the following tones: H1 - 925/628 at 2Hz H4 - French 554: 100ms / 440: 400ms H5 - Swedish 660: 150ms / Off: 150ms 8 - Whoop 500-1200 3s/0.5s 12 - Sweep 800/970 at 1Hz 15 - Sweep 2400-2850 at 1Hz 17 - 970:ISO8201 0.5s 18 - 2850:ISO820 0.5s Loop powered base sounder and beacon (YBN-R/3 and YBO-R/SCI bases) Notes: 1) The beacon function of this device is not included in the scope of this approval 2) Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) LPCB Ref. No.
CHQ-WS2(HFP)
164h/02
CHQ-WS2(WHT)
164h/02
CHQ-WS2/W
164h/02
YBO-BSB(HFP)
164h/03
188
January 2009
SECTION 7: PART
Certificated Products 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Loop powered base sounder and beacon white version (YBN-R/3 and YBO-R/SCI bases) Notes: 1) The beacon function of this device is not included in the scope of this approval 2) Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms LPCB Ref. No.
SOUNDERS
YBO-BSB(WHT)
164h/03
January 2009
189
PART 3: SECTION 7
SOUNDERS
Certificated Products 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Bases: YBN-R/3 Analogue mounting base (ivory and white) YBO-R/SCI Isolator base LPCB Ref. No.
190
January 2009
SECTION 7: PART
Certificated Products Flashtone Banshee MT 3) Approved voltage range 10-28V Conventional 32 tone sounder with 1 Watt Xenon beacon (shallow & deep bases) Notes: 1) Suitable for Type A indoor application when used with shallow base & deep base 2) Approved with body moulding & lens colour variations 3) Approved at 12 & 24 VDC 4) Meets requirements of EN 54-3: 2001 with the following tones: Sound 2 Banshee LF Fast Sweep - 800Hz - 950Hz Swept @ 9Hz Sound 13 Banshee / Bedlam HF Fast Sweep - 2400Hz - 2900Hz @ 9Hz Sound 15 Banshee / Bedlam HF Continuous - Continuous 2900Hz @ 3Hz Sound 19 Slow Whoop (Dutch) - 500Hz - 1200Hz over 3.5s then silence for 0.5s repeat Sound 20 DIN Tone (DK) - 1200Hz - 500Hz over 1s, silence 10ms repeat Sound 21 French Fire Sound - 554Hz for 100ms & 440Hz for 400ms Conventional 32 tone sounder with LED beacon & deep bases) Notes: 1) Suitable for Type A indoor application when used with shallow or deep base 2) Suitable for Type B outdoor application when used with deep base & sealing gasket 3) Approved at 12 & 24 VDC 4) Approved with body moulding & lens colour variations 5) Meets requirements of EN 54-3: 2001 with the following tones: Sound 2 Banshee LF Fast Sweep - 800Hz - 950Hz Swept @ 9Hz Sound 13 Banshee / Bedlam HF Fast Sweep - 2400Hz - 2900Hz @ 9Hz Sound 15 Banshee / Bedlam HF Continuous - Continuous 2900Hz @ 3Hz Sound 19 Slow Whoop (Dutch) - 500Hz - 1200Hz over 3.5s then silence for 0.5s repeat Sound 20 DIN Tone (DK) - 1200Hz - 500Hz over 1s, silence 10ms repeat Sound 21 French Fire Sound - 554Hz for 100ms & 440Hz for 400ms Conventional 32 Tone Sounder Notes: 1) Suitable for Type A indoor application only 2) Approved at 12 & 24 VDC 3) Approved with body moulding colour variations 4) To be used in conjunction with a suitable detector when supplied without cover 5) Meets requirements of EN 54-3: 2001 with the following tones: Sound 2 Banshee LF Fast Sweep - 800Hz - 950Hz Swept @ 9Hz Sound 13 Banshee / Bedlam HF Fast Sweep - 2400Hz - 2900Hz @ 9Hz Sound 15 Banshee / Bedlam HF Continuous - Continuous 2900Hz @ 3Hz Sound 19 Slow Whoop (Dutch) - 500Hz - 1200Hz over 3.5s then silence for 0.5s repeat Sound 20 DIN Tone (DK) - 1200Hz - 500Hz over 1s, silence 10ms repeat Sound 21 French Fire Sound - 554Hz for 100ms & 440Hz for 400ms Conventional 32 tone sounder with bipolar supply input (shallow & deep bases) Notes: 1) Suitable for Type A indoor application when used with shallow or deep base 2) Suitable for Type B outdoor application when used with deep base & sealing gasket 3) Approved at 12 & 24 VDC 4) Approved with body moulding colour variations 5) Meets requirements of EN 54-3: 2001 with the following tones: Sound 2 Banshee LF Fast Sweep - 800Hz - 950Hz Swept @ 9Hz Sound 13 Banshee / Bedlam HF Fast Sweep - 2400Hz - 2900Hz @ 9Hz Sound 15 Banshee / Bedlam HF Continuous - Continuous 2900Hz @ 3Hz Sound 19 Slow Whoop (Dutch) - 500Hz - 1200Hz over 3.5s then silence for 0.5s repeat Sound 20 DIN Tone (DK) - 1200Hz - 500Hz over 1s, silence 10ms repeat Sound 21 French Fire Sound - 554Hz for 100ms & 440Hz for 400ms Conventional 2 tone sounder Notes: 1) Suitable for Type A indoor application only 2) Approved with body moulding colour variations 3) Meets requirements of EN 54-3: 2001 with the following tones: Sound 1 Continuous 850 Hz Sound 2 Fast Sweep 800 - 950 Hz @ 9 Hz LPCB Ref. No. 715a/02
SOUNDERS
715a/03
Wafer MT
715a/04
Bipolar Banshee MT
715a/05
FM Bedrrom
715a/06
Bases: Shallow base (various colour options) Deep base (various colour options)
January 2009
191
PART 3: SECTION 7
SOUNDERS
WMSOU-xx-P01
166c/10
IBSST-xx-P01
166c/11
IBSOU-xx-P01 DBSST-xx-P01-C
166c/12 166c/13
DBSOU-xx-P01-C
166c/14
EMA1224FR EMA1224FW
166c/15 166c/16
192
January 2009
SECTION 7: PART
Certificated Products SOU-LPR-14 SOU-LPW-14 SOU-SR-14 SOU-SW-14 SOU-SSR-14 SOU-SSW-14 DBS-14 DBS-R-14 DBS-W-14 DBS1224FW DBS-4 DBS-R-4 DBS-W-4 DBS1224B4W WMSST-xx-P02 Conventional Type A wall mounted sounder with low profile mounting box (red) Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Conventional Type A wall mounted sounder with low profile mounting box (white) Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Conventional Type A wall mounted sounder with mounting box (red) Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Conventional Type A wall mounted sounder with mounting box (white) Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Conventional Type B wall mounted sounder with mounting box & sealing kit (red) Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Conventional Type B wall mounted sounder with mounting box & sealing kit (white) Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Conventional Type A sounder base (white) Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Conventional Type A sounder base (white), supplied with red lid Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Conventional Type A sounder base (white), supplied with white lid Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Conventional Type A wall mounted sounder Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Conventional Type A sounder base (white) Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Conventional Type A sounder base (white), supplied with red lid Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Conventional Type A sounder base (white), supplied with white lid Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Conventional Type A wall mounted sounder Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Intelligent wall mounted sounder strobe with short circuit isolator Notes: 1) xx indicates body colour. R=Red, W=Bright White 2) xx indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Meets the requirement of EN54-3 for all tones and output levels at voltage range 15.-32v. Intelligent wall mounted sounder with short circuit isolator Note: 1) xx indicates body colour. RR=Red, WW=Bright White Meets the requirements of EN54-3 for all tones and output levels at voltage 15-32v. Intelligent integrated detector base sounder strobe with short circuit isolator Notes: 1) xx indicates body colour. R=Red, W=Bright White, D=Detector White, K=Black 2) xx indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Meets the requirements of EN54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20 which are approved at maximum volume only. Intelligent integrated detector base sounder with short circuit isolator Note: 1) xx indicates body colour. RR=Red, WW=Bright White, DD=Detector White, KK=Black Intelligent non-integrated detector base sounder strobe with short circuit isolator Notes: 1) xx indicates body colour. R=Red, W=Bright White 2) xx indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Intelligent non-integrated detector base sounder with short circuit isolator Note: 1) xx indicates body colour. RR=Red, WW=Bright White Meets the requirements of EN54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20 which are approved at maximum volume only. Conventional Type A wall mounted sounder strobe (ELPBR/W, ESBR/W and ESBRS/WS bases) Notes: LPCB Ref. No. 166c/17 166c/18 166c/19 166c/20 166c/21 166c/22 166c/23 166c/24 166c/25 166c/26 166c/27 166c/28 166c/29 166c/30 166d/01
SOUNDERS
WMSOU-xx-P02
166d/02
IBSST-xx-P02
166d/03
IBSOU-xx-P02 DBSST-xx-P02-C
166d/04 166d/05
DBSOU-xx-P02-C
166d/06
EMA12Fxxxx
166c/31
January 2009
193
PART 3: SECTION 7
SOUNDERS
Certificated Products 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 1014v 2) xxxx indicates body colour. RS=Red, WS=White 3) xxxx indicates lens colour. SR=Red, SA=Amber, SC=Clear Conventional Type A wall mounted sounder strobe (ELPBR/W, ESBR/W and ESBRS/WS bases) Notes: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 2127v 2) xxxx indicates body colour. RS=Red, WS=White 3) xxxx indicates lens colour. S-=Red and Amber supplied, SR=Red, SA=Amber, SB=Blue Conventional Type A wall mounted sounder strobe (white) (ELPBR/W, ESBR/W and ESBRS/WS bases) Notes: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 1014v 2) xxWx indicates base type. LP=ELPBR/W, -S=ESBR/W, SS=ESBRS/WS. 3) xxWx indicates lens colour. R=Red, A=Amber, B=Blue, G=Green Conventional Type A wall mounted sounder strobe (red) (ELPBR/W, ESBR/W and ESBRS/WS bases) Notes: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 2127v 2) xxRx indicates base type. LP=ELPBR/W, -S=ESBR/W, SS=ESBRS/WS. 3) xxRx indicates lens colour. R=Red, A=Amber, B=Blue Intelligent wall mounted sounder strobe with short circuit isolator. Meets the requirements of EN54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20 which are approved at maximum volume only. Intelligent wall mounted sounder strobe. Meets the requirements of EN54-3 for all tones and output levels at voltage range 1532v. Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20 which are approved at maximum volume only. LPCB Ref. No.
EMA24Fxxxx
166c/32
SST-xxWx-14
166c/33
SST-xxRx-14
166c/34
Bases: ELPBR/W Low profile base IP21C, red or white ESBR/W Standard base IP54, red or white ESBRS/WS Standard base and IP66 sealing kit, red or white
18-980516
717a/02
18-980505
717a/03
194
January 2009
SECTION 7: PART
Certificated Products used with the deep base only 2) Meets requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Conventional Sounder with LED Strobe (Amber Head / White Base) (18-980467, 18980513, 18-980468 & 18-980514 bases) Notes: 1) The above sounder is Type A when used the with the shallow base & Type B when used with the deep base only 2) Meets requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Conventional Sounder (Red) (18-980467, 18-980513, 18-980468 & 18-980514 bases) Notes: 1) The above sounder is Type A when used the with the shallow base Type B when used with the deep base only 2) Meets requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Conventional Sounder (White) (18-980467, 18-980513, 18-980468 & 18-980514 bases) Notes: 1) The above sounder is Type A when used the with the shallow base & Type B when used with the deep base only 2) Meets requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Universal base sounder (white) Notes: 1) Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Universal base sounder (cream) Notes: 1)Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Base sounder Notes: 1) Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Universal base sounder (Red) Notes: 1) Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Base sounder with diode Notes: 1) Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Conventional Sounder with (Red Head / Red Base) LED Strobe Common Operation 18-980513, 18-980468 & 18-980514 base) Notes: 1) The above sounder is Type A when used with the shallow base & Type B when used with the deep base only. 2) Meets requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13. Conventional Sounder with Red LED Strobe Common Operation (Clear Lens / White Base) (18-980467, 18-980513, 18-980468 & 18-980514 bases) Notes: 1) The above sounder is Type A when used with the shallow base & Type B when used with the deep base only. 2) Meets requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13. Conventional Sounder with LED Strobe Common Operation (Amber Head / Red Base) (18-980467, 18-980513, 18-980468 & 18-980514 bases) Notes: 1) The above sounder is Type A when used with the shallow base & Type B when used with the deep base only. 2) Meets requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13. Conventional Sounder with Red LED Strobe (Clear Lens / White Base) (18-980467, 18-980513, 18-980468 & 18-980514 bases) Notes: 1) The above sounder is Type A when used with the shallow base & Type B when used with the deep base only. 2) Meets requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13. Conventional Sounder with LED Strobe Common Operation (Red Head / White Base) (18-980467, 18-980513, 18-980468 & 18-980514 bases) Notes: 1) The above sounder is Type A when used with the shallow base & Type B when used with the deep base only. 2) Meets requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13. Conventional Sounder with LED Strobe Common Operation (Amber Head / White Base) (18-980467, 18-980513, 18-980468 & 18-980514 bases) Notes: 1) The above sounder is Type A when used with the shallow base & Type B when used LPCB Ref. No. 717a/04
SOUNDERS
18-980517
18-980527
717a/05
18-980528
717a/06
18-980582
717a/11
18-980612
717a/12
18-980613
717a/13
18-980723
717a/16
18-980724
717a/17
January 2009
195
PART 3: SECTION 7
SOUNDERS
Certificated Products with the deep base only. 2) Meets requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13. Bases: 18-980467 Shallow base (red) 18-980513 Shallow base (white) 18-980468 Deep base (red) 18-980514 Deep base (white) LPCB Ref. No.
Certificate No: 166c to EN 54-3: 2001 Certificate No: 166d to EN 54-3: 2001 and CEA GEI 1-052 Draft 2.0: 11.06.97 Certificated Products MI-WSDB-X-XX Intelligent wall mounted sounder strobe Notes: 1) x-xx indicates body colour. R=Red, W=Detector White 2) x-xx indicate lens colour. RD=Red, AM=Amber, GR=Green, BL=Blue, CL=Clear Intelligent wall mounted sounder Note: 1) x indicates body colour. R=Red, W=Detector White Intelligent integrated detector base sounder strobe Notes: 1) x-xx indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black 2) x-xx indicate lens colour. RD=Red, AM=Amber, GR=Green, BL=Blue, CL=Clear Intelligent integrated detector base sounder Note: 1) x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black Intelligent wall mounted sounder strobe with short circuit isolator Notes: 1) x-xx indicates body colour. R=Red, W=Detector White 2) x-xx indicate lens colour. RD=Red, AM=Amber, GR=Green, BL=Blue, CL=Clear Intelligent wall mounted sounder with short circuit isolator Note: 1) x indicates body colour. R=Red, W=Detector White Intelligent integrated detector base sounder strobe with short circuit isolator Notes: 1) x-xx indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black 2) x-xx indicate lens colour. RD=Red, AM=Amber, GR=Green, BL=Blue, CL=Clear Intelligent integrated detector base sounder with short circuit Note: 1) x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black LPCB Ref. No. 166c/09
MI-WSD-X MI-IBSDB-X-XX
166c/10 166c/11
MI-IBSD-X MI-WSDB-X-XX-I
166c/12 166d/01
MI-WSD-X-1 MI-IBSDB-X-XX-I
166d/02 166d/03
MI-IBSD-X-I
166d/04
196
January 2009
SECTION 7: PART
Certificated Products NI-403 Fixed tone: 1.35Hz (400ms on / 340ms off) Intelligent sounder strobe Notes: Meets the requirements of EN 54-3: 2001 at the following tones: Mode I (for pre alarm): 0.61Hz (430ms on / 1200ms off) Mode II (for fire alarm): 1.30Hz (430ms on / 340ms off) LPCB Ref. No. 548e/02
SOUNDERS
Notifier By Honeywell
Charles Avenue, Burgess Hill, West Sussex RH15 9UF UK Tel: +44 (0)1444 230230 Fax: +44 (0)1444 230689 E-mail: sales@notifierfiresystems.co.uk Website: www.notifierfiresystems.co.uk
Certificate No: 166c to EN 54-3: 2001 Certificate No: 166d to EN 54-3: 2001 and CEA GEI 1-052 Draft 2.0: 11.06.97 Certificated Products AWSB32/X/X Intelligent wall mounted sounder strobe Notes: 1) x/x indicates body colour. R=Red, W=Detector White 2) x/x indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Intelligent wall mounted sounder Note: 1) x indicates body colour. R=Red, W=Detector White Intelligent integrated detector base sounder strobe Notes: 1) x/x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black 2) x/x indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Intelligent integrated detector base sounder Note: 1) x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black Intelligent wall mounted sounder strobe with short circuit isolator Notes: 1) x/x indicates body colour. R=Red, W=Detector White 2) x/x indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Intelligent wall mounted sounder with short circuit isolator Note: 1) x indicates body colour. R=Red, W=Detector White Intelligent integrated detector base sounder strobe with short circuit isolator Notes: 1) x/x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black 2) x/x indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Intelligent integrated detector base sounder with short circuit isolator Note: 1) x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black 4 Tone wall mounting conventional sounder (red) Note: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v 4 Tone wall mounting conventional sounder (white) Note: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Conventional Type A wall mounted sounder (red) Note: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Conventional Type A wall mounted sounder (white) Note: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v LPCB Ref. No. 166c/09
AWS32/X ABSB32/X/X
166c/10 166c/11
ABS32/X AWSB32/X/X-I
166c/12 166d/01
AWS32/X-I ABSB32/X/X-I
166d/02 166d/03
ABS32/X-I NS4/R
166d/04 166c/01
NSR4/W
166c/02
NS14/R
166c/15
NS14/W
166c/16
January 2009
197
PART 3: SECTION 7
SOUNDERS
6000/SSW2
201n/02
6000/SSR2/NL
201n/03
6000/SSW2/NL
201n/04
S-C481
548e/01
198
January 2009
SECTION 7: PART
SOUNDERS
WMSOU-XX-P01
166c/10
IBSST-XX-P01
166c/11
IBSOU-XX-P01 DBSST-XX-P01-C
166c/12 166c/13
DBSOU-XX-P01-C
166c/14
WMSST-XX-P02
166d/01
WMSOU-XX-P02
166d/02
IBSST-XX-P02
166d/03
IBSOU-XX-P02
166d/04
DBSST-XX-P02-C
166d/05
DBSOU-XX-P02-C
166d/06
January 2009
199
PART 3: SECTION 7
SOUNDERS
Certificated Products 1) xx indicates body colour. RR=Red, WW=Bright White Meets the requirements of EN-54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20, which are approved at maximum volume only. Intelligent wall mounted sounder strobe Note: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-28v. Intelligent integrated detector base sounder strobe. Notes: 1) Meets the requirements of EN54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20, which are approved at maximum volume only. Intelligent wall mounted sounder strobe Meets the requirements of EN54-3 for all tones and output levels at voltage range 1532v. Intelligent integrated detector base sounder strobe. Meets the requirements of EN54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20 which are approved at maximum volume only. LPCB Ref. No.
WMSST-RP-P30
166d/07
IBSST-DR-P30
166d/08
WMSST-RR-P29 IBSST-DR-P29
166c/35 166c/36
601SB
681g/02
601SBD
681g/03
602SB
681g/04
602SBD
681g/05
901SB
681g/06
912SB
681g/07
200
January 2009
SECTION 7: PART
Certificated Products Notes: 1) Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz Analogue addressable type A sounder base Notes: 1) Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz Symphoni MX addressable loop powered Type A sounder (red) with short circuit isolator Notes: 1) Meets the requirements of EN 54-3 at tones 1, 2, 6, 9. Symphoni MX addressable loop powered Type A sounder (white) with short circuit isolator Notes: 1) Meets the requirements of EN 54-3 at tones 1, 2, 6, 9. Symphoni MX addressable loop powered Type B sounder (red) with short circuit isolator Notes: 1) Meets the requirements of EN 54-3 at tones 1, 2, 6, 9. Symphoni MX addressable loop powered Type A sounder beacon (red) with short circuit isolator Notes: 1) Meets the requirements of EN 54-3 at tones 1, 2, 6, 9. Symphoni MX addressable loop powered Type A sounder beacon (white) with short circuit isolator Notes: 1) Meets the requirements of EN 54-3 at tones 1, 2, 6, 9. Symphoni MX addressable loop powered Type B sounder beacon (red) with short circuit isolator Notes: 1) Meets the requirements of EN 54-3 at tones 1, 2, 6, 9. LPCB Ref. No.
SOUNDERS
812SB
681g/08
LPSY800-R LPSY800-W
378e/01 378e/02
LPSY865 LPAV800-R
378e/03 378e/04
LPAV800-W
378e/05
LPAV865
378e/06
Vimpex Limited
Star Lane, Great Wakering, Essex SS3 0PJ UK Tel: +44 (0) 1702 216999 Fax: +44 (0) 1702 216699 E-mail: sales@vimpex.co.uk Website: www.vimpex.co.uk
Certificate No: 692a to EN 54-3: 2001 Certificated Products MBF-6EV-24 MBF-8EV MBA-6 + BBX.4 MBA-8 + BBX.4 6" (150mm) 24Vdc fire alarm bell with aluminium gong 8" (200mm) 24Vdc fire alarm bell with aluminium gong 6" (150mm) fire alarm bell with aluminium gong complete with back box 8" (200mm) fire alarm bell with aluminium gong complete with back box LPCB Ref. No. 692a/01 692a/02 692a/04 692a/05
January 2009
201
PART 3: SECTION 8
FIRE RESISTANT CABLES This section lists fire resistant cables for use in fire safety, fire detection and fire alarm systems and other applications where specifications require cables with specific performance in the event of a fire. BS 5839-1:2002 Fire detection and fire alarm systems for buildings. Code of practice for system design, installation, commissioning and maintenance BS 5839-1:2002 includes new requirements for fire resistant cables for fire detection and alarm systems. It calls for Standard and Enhanced fire resistant cables and defines the requirements for these in Clause 26.2. These cables have to comply with BS EN 60702-1 (with a polymeric sheath), BS 7629 or BS 7846, and: - Standard fire resisting cables also have to: a) achieve Class PH30 when tested in accordance with EN 50200:2000. and b) maintain circuit integrity when exposed to a special flame / mechanical shock / water spray sequence equivalent to achieving a duration of 30 minutes when tested in accordance with BS 8434-1:2003. - Enhanced fire resisting cables also have to: a) achieve a 120 minute survival when tested in accordance with EN 50200:2000. and b) maintain circuit integrity when exposed to a special flame / mechanical shock / water spray sequence equivalent to achieving a duration of 120 minutes when tested in accordance with BS 8434-2:2003. Cables complying with these requirements are listed as Standard or Enhanced under BS 5839-1, Clause 26.2. Building Regulations 2000 - Fire Safety - Approved Document B The Building Regulations 2000 - Fire Safety - Approved Document B - Volume 2 - Buildings other than dwelling houses (Amended 2007) defines protected power circuit to be able to continue to function during a fire. A protected circuit for operation of equipment in the event of fire should consist of a cable meeting at least the requirements of PH30 when tested in accordance with EN 50200. Larger or complex buildings may require fire protection systems to operate for extended periods during fire and guidance on such systems is given in BS 5839-1, BS 5266-1 and BS 7346-6. Other Standards Used The other standards and test methods currently used for certification are listed below. This list includes some "withdrawn" standards. Where possible, these will be replaced by the superseding standards when certificates are renewed. However, where withdrawn standards are called up by current standards, certification to the withdrawn standard may need to be maintained until the calling standard is amended to remove the reference: - BS 6207-1:1995 Mineral insulated cables with rated voltage not exceeding 750V - BS 6387:1994 Performance requirements for cables required to maintain circuit integrity under fire conditions - BS 6425-1:1990 Gases evolved during combustion of electric cables. Part 1: Method for determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables - BS 7346-6:2005 Components for smoke and heat control systems - Part 6: Specification for cable systems - BS 7622-2:1993 Measurement of smoke density of electric cables burning under defined conditions - BS 7629-1:1997 Thermosetting insulated cables with limited circuit integrity when affected by fire. Part 1: Multicore cables.(This version of the standard will remain current until 31st March 2006) - BS 7629-1:1997 (Incorporating Amendment Nos.1 and 2) - Thermosetting insulated cables with limited circuit integrity when affected by fire. Part 1: Multicore cables.(The provisions introduced by amendment No.1: 2004 are effective from 1st April 2004) - BS 7629-2:1997 Thermosetting insulated cables with limited circuit integrity when affected by fire. Part 2: Multipair cables - BS 7846:2000 Electric cables 600/1000V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire. (This version of the standard will remain current until 31st March 2006) - BS 7846:2000 (Incorporating Amendment No.1) - Electric cables 600/1000V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire. (The provisions introduced by amendment No.1: 2004 are affective from 1st April 2004)
202
January 2009
SECTION 8: PART
FIRE RESISTANT CABLES - BS 8434-1:2003 Method of test for assessment of the fire integrity of electric cables - Part 1: test for unprotected small cables for use in emergency circuits - BS EN 50200 with addition of water spray - BS 8434-2:2003 Method of test for assessment of the fire integrity of electric cables - Part 2: test for unprotected small cables for use in emergency circuits- BS EN 50200 with a 930C flame and with water spray - BS 8491:2008 Method for assessment of fire integrity of large diameter power cables for use as components for smoke and heat control systems and other certain active fire safety systems - EN 50200:2000 Method of test for resistance to fire of unprotected small cables for use in emergency circuits - EN 50200:2006 Method of test for resistance to fire of unprotected small cables for use in emergency circuits - EN 50266:2001 Common test methods for cables under fire conditions - Test for vertical flame spread of vertically mounted bunched wires or cables - EN 50267-2-1:1999 Common test method for cables under fire conditions- tests on gases evolved during combustion of materials from cables - procedures - Determination of the amount of halogen acid gas -EN 50267-2-3:1999 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Procedure 2-3: Procedures - Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity - EN 50268-2:2000 Common test methods for cables under fire conditions. Measurement of smoke density of cables burning under defined conditions - EN 60702-1:2002 Mineral insulated cables and their terminations with rated voltage not exceeding 750V - EN 61034-2:2005 Measurement of smoke density of cables burning under defined conditions - IEC 331:1970 Fire resisting characteristics of electric cables - IEC 60754-1:1994 Tests on gases evolved during combustion of materials from cables - Part 1: Determination of the amount of halogen acid gas - IEC 60754-2:1991 Tests on gases evolved during combustion of electric cables - Part 2: Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring pH and conductivity - IEC 60331-21:1999 Tests for electric cables under fire conditions - Circuit integrity - Part 21 Procedure and requirements - Cables of rated voltage up to and including 0,6/1,0kV
2M KABLO A.S.
Evren Oto Sanayi Sitesi, 1 Kisim, 1585 Sk No.1, Esenyurt, Istanbul, Turkey Tel: +90 212 672 7314 Fax: +90 212 672 7312 E-mail: sales@2mkab.com Website: www.2mkab.com
Certificate No: 711a to BS EN 50200: 2006 Class PH120
January 2009
203
PART 3: SECTION 8
FIRE RESISTANT CABLES
Notes: 1) Solid conductor only. 2) External diameter of this conductor is 0.80mm.
NoBurn Platinum
Nominal csa of conductor 2 (mm ) 1.0 1.5 2.5 4.0 Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2 BS 7629-1 (Incorporating Amendments No.1 & 2) Complies Complies Complies Complies
(3)
BS EN 50200
BS 84341
(4)
(3)
(3)
(3)
30min 30min
682a/01
(4)
(5)
30min
(4)
Standard
(5)
30min
(4)
Standard
(5)
Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), the NoBurn Platinum cables listed met the requirements of smoke density of BS EN 50268-2:2000, fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-21:1999. 4) The duration of 30min when tested in accordance with BS 8434-1:2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1:2002. 5) The NoBurn Platinum cables listed conform to BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), met Class PH120 when tested in accordance with BS EN 50200:2006 and met the 30min duration when tested in accordance with BS 8434-1:2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1:2002.
204
January 2009
SECTION 8: PART
Uo/U 450/750V Note: 1) The Firetec Power LSZH cable also met Category C, W, Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.
Certificate No: 221a to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU).
January 2009
205
PART 3: SECTION 8
FIRE RESISTANT CABLES
2) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the st CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31 March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators.
Certificate No: 221e to BS 7629-1:1997 (Incorporating Amendment No.1), BS EN 50200:2000 Class PH30, BS 8434-1:2003 & BS 5839-1:2002 Clause 26.2d
Certificate No: 221f to BS 7629-1:1997 (Inc Amdmnt No.1), BS 5839-1:2002 Clause 26.2e, BS EN 50200:2000 Class PH120 BS 8434-2:2003 120min
Core Construction (excluding drain wire & earth) 2,3 & 4 2,3 & 4 2,3 & 4
(1)
(4)
(5)
2.5
(1)
(3)
(4)
(5)
206
January 2009
SECTION 8: PART
Nominal csa of conductor 2 (mm ) 4.0
(2)
Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendment No.1), the FIRETEC ENHANCED Multicore LSZH cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS EN 50267-2-1: 1999. 4) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2 e) of BS 5839-1: 2002. 5) The FIRETEC ENHANCED Multicore LSZH cables listed conform to BS 7629-1: 1997 (Incorporating Amendment No.1), met Class PH120 when tested in accordance with EN 50200: 2000 and met a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
Certificate No: 221g to BS 7846: 2000 This certificate is to a withdrawn version of the BS 7846: 2000. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU).
January 2009
207
PART 3: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of 2 conductor (mm ) 2.5 4.0 Uo/U 300/500 V Note: 1) The above range is certified in both bare and covered constructions. Core Construction 2, 3, 4 & 7 2 BS 6387 C, W, Z C, W, Z BS EN 60702-1 Complies Complies LPCB Ref. No.
Notes: 1) The above range is certified in both bare and covered constructions. 2) For cables with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the manufacturer.
Notes: 1) The above range is certified in both bare and covered constructions 2) For cables with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the manufacturer.
208
January 2009
SECTION 8: PART
Firetec Armoured LSZH
Nominal csa of 2 conductor (mm ) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 Uo/U 600/1000 V Core Construction 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 BS 7846 (Incorporating Amendments Nos. 1 & 2) (1) F2 (1) F2 (1) F2 (1) F2 (1) F2 (1) F2 (1) F2 (1) F2 (1) F2 (1) F2 (1) F2 (1) F2 (1) F2 (1) F2 (1) F2 (1) F2 (1) F2 LPCB Ref. No. 221j/01
Note: 1) In meeting the requirements of BS 7846: 2000 (Incorporating Amendments Nos 1 & 2), the Firetec Armoured LSZH cables listed met the requirements of BS 6387: 1994 Clause 11.1 Category C, W & Z.
Firetec Armoured
Nominal csa of 2 conductor (mm ) 1.5 4.0 6.0 6.0 10 16 Uo/U 600/1000 V Note: 1) In meeting the requirements of BS 7846: 2000 (Incorporating Amendments Nos. 1 & 2), the Firetec Armoured Cables listed met the requirements of BS 6387: 1994 Clause 11.1 Category C, W & Z. Core Construction 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 BS 7846 (Incorporating Amendments Nos. 1 & 2) (1) F2 (1) F2 (1) F2 (1) F2 (1) F2 (1) F2 LPCB Ref. No. 221k/01
Certificate No: 221m to BS 7846: 2000 N.B. This certificate is to a withdrawn version of the above standard. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn version of the standard, is maintained because cables meeting the withdrawn version of the standard are still requested by some regulators outside of the EU. (See appendix for further details).
Firetec Armoured
Nominal csa of 2 conductor (mm ) 1.5 2.5 4.0 6.0 10 16 Uo/U 600/1000 V Note: 1) In meeting the requirements of BS 7846: 2000, the Firetec Armoured Cables listed met the requirements of BS 6387: 1994 Clause 11.1 Category C, W & Z. Core Construction 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 BS 7846 (see notes 1 & 2) F2 F2 F2 F2 F2 F2 LPCB Ref. No. 221m/01
January 2009
209
PART 3: SECTION 8
FIRE RESISTANT CABLES
2) BS 7846: 2000 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the st CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31 March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators. Certificate 221k covers cables certified in accordance with BS 7846: 2000 (Incorporating Amendments Nos. 1 & 2).
ALPHAFIRE FPC4
Nominal csa of 2 conductors (mm ) 1.0 1.5 2.5 4.0 Uo/U 300/500 V Notes: 1) Solid and stranded conductors. 2) Stranded conductor only. Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl LPCB Ref. No. 568a/01
210
January 2009
SECTION 8: PART
Uo/U = 450/750V Notes: 1) Clause 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable having only one core. 2) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. 3) To satisfy the requirement of BS 6387, testing for C, W & Z categories were conducted using a 20mm stainless steel conduit as the other metallic element.
Firepro
Nominal csa of conductor (mm) 1.5 (1) 10 (1) 16 (1) 2.5 (1) 4.0 (1) 6.0 Uo/U 450/750V Notes: 1) Stranded conductor only. 2) Clause 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable having only one core. 3) To satisfy the requirement of BS 6387, testing for C, W & Z categories were conducted using a 20mm stainless steel conduit as the other metallic element. 4) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element.
(1)
Core Construction One (4, 5) One (4, 5) One (3) One (3) One (3) One
(3)
BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl
January 2009
211
PART 3: SECTION 8
FIRE RESISTANT CABLES
5) To satisfy the requirement of BS 6387, testing for W & Z categories were conducted using a 20mm stainless steel conduit as the other metallic element. 6) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.
Cavicel SpA
Via Caduti del Lavoro, 18/A 20096 Pioltello, Milan, Italy Tel: +39 02 9216 0521 Fax: +39 02 9216 0753 E-mail: cavicel@cavicel.com Website: www.cavicel.com
Certificate No: 217d to BS 6387:1994 & BS 6425-1: 1990
BS 6425-1 (outer covering) <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI
Certificate No: 217f to BS 7629-1:1997 (Incorporating Amendment No.1), BS EN 50200: 2000 Class PH30 & BS 5839-1: 2002 Clause 26.2
BS EN 50200
217f/01
Notes: 1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendment No.1), the Firecel SR/114 H cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (binder + insulation + sheath) when tested in accordance with BS EN 50267-2-1: 1999. 2) The Firecel SR/114 H cables listed conform to BS 7629-1: 1997 (Incorporating Amendment No.1), met Class PH30 when tested in accordance with BS EN 50200: 2000 and met the requirements of the additional fire, mechanical shock and water test described in Clause 26.2 d) of BS 5839-1: 2002, and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
Certificate No: 217g to BS 7629-1:1997 (Incorporating Amendment No.1), BS EN 50200:2000 Class PH120, BS 8434-2:2003 120min & BS 5839-1:2002 Clause 26.2e
212
January 2009
SECTION 8: PART
Firecel SR 114 E
Nominal csa of 2 conductor (mm ) 1.0 1.5 2.5 4.0 Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendment No.1), the Firecel SR 114 E cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-2-1: 1999. 2) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2e) of BS 5839-1: 2002. 3) The Firecel SR 114 E cables listed conform to BS 7629-1: 1997 (Incorporating Amendment No.1), met Class PH120 when tested in accordance with BS EN 50200: 2000 and met the 120min duration when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002. Core Construction 2, 3 & 2, 3 & 2, 3 & 2, 3 & 4 4 4 4 BS 7629-1 (Incorporating Amendment No 1) (1) Complies (1) Complies (1) Complies (1) Complies BS EN 50200 BS 8434-2
(2)
BS 5839-1 Clause 26.2 Enhanced (3) Enhanced (3) Enhanced (3) Enhanced
(3)
217g/01
Certificate No: 076a/01 to BS 7629-1:1997 (Inc. Amd. Nos. 1 and 2) and BS 6387:1994
Fire Cet
Nominal csa of conductor (mm) 1.0 (1) 1.5 (2) 2.5 (3) 4.0 Uo/U 300/500V Notes: 1) Solid conductor only 2) Solid & Stranded conductors 3) Stranded conductor only 4) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), the FIRE CET cables listed met the requirements of smoke density of BS EN 50268-2:2000 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS EN 50267-2-1:1999.
(1)
Core construction drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4
BS 7629-1 (incorporating Amendments Nos. 1 and 2) (4) Complies (4) Complies (4) Complies (4) Complies
BS6387 C, W, Z C, W, Z C, W, Z C, W, Z
January 2009
213
PART 3: SECTION 8
FIRE RESISTANT CABLES
Context Plus
Nominal csa of conductor 2 (mm ) 1.0 1.5 2.5 4.0 Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2 BS 7629-1 (Incorporating Amendments No.1 & 2) Complies Complies Complies Complies
(3)
BS EN 50200
BS 84341
BS 5839-1Clause 26.2
(3)
(3)
(3)
(4)
(5)
682a/01
(4)
(5)
(4)
(5)
(4)
(5)
Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), the Context Plus cables listed met the requirements of smoke density of BS EN 50268-2:2000, fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-21:1999. 4) The duration of 30min when tested in accordance with BS 8434-1:2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1:2002. 5) The Context Plus cables listed conform to BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), met Class PH120 when tested in accordance with BS EN 50200:2006 and met the 30min duration when tested in accordance with BS 8434-1:2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1:2002.
Dtwyler Cables
Unit of Dtwyler Switzerland Inc, Gotthardstrasse 31, CH-6460 Altdorf, Switzerland Tel: +41 41 875 1122 Fax: +41 41 875 1860 E-mail: info.ch@daetwyler-cables.com Website: www.daetwyler-cables.com
Certificate No: 172b to BS 7629-1:1997 (Incorporating Amendment No.1),BS 6387:1994, BS EN 50200:2000 Class PH30, BS 84341:2003 30min & BS 5839-1:2002 Clause 26.2d
BS 6387
BS EN 50200
BS 84341
(1)
(1)
C, W, Z C, W, Z C, W, Z
30min 30min
(2)
172b/01
(2)
(3)
30min
(2)
Standard
(3)
Uo/U 300/500V
214
January 2009
SECTION 8: PART
Doncaster Cables
Millfields Industrial Estate, Arksey Lane, Bentley, Doncaster, South Yorkshire DN5 0SJ UK Tel: +44 (0)1302 821700 Fax: +44 (0)1302 821701
Certificate No: 338a to BS 7629-1: 1997 (Inc. Amd. No.1), BS EN 50200:2000 Class PH30, BS 8434-1:2003 30min & BS 58391:2002 Clause 26.2d
Firesure
Nominal csa of conductor 2 (mm ) 1.0 1.5 2.5 4.0 Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1:1997 (Incorporating Amendment No.1) the Firesure cables listed met the requirements of smoke density of BS EN 50268-2:2000, fire resistance requirements C, W, Z in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCI on the (outer covering, binding tape & insulation) when tested in accordance with BS EN 50267-2-1:1999. 2) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d of BS 5839-1:2002. 3) The Firesure cables listed conform to BS 7629-1: 1977 (Incorporating Amendment No 1) met Class PH30 when tested in accordance with BS EN 50200:2000 and met the 30min duration when tested in accordance with BS 8434-1:2003 and hence met the requirement for a standard fire resistant cable described in Clause 26.2 of BS 5839-1:2002. Core Construction 2, 3 & 2, 3 & 2, 3 & 2, 3 & 4 4 4 4 BS 7629-1 (Incorporating Amendment No.1) (1) Complies (1) Complies (1) Complies (1) Complies BS EN 50200 Class PH30 Class PH30 Class PH30 Class PH30 BS 84341 30min (2) 30min (2) 30min (2) 30min
(2)
BS 5839-1 Clause 26.2 Standard (3) Standard (3) Standard (3) Standard
(3)
Certificate No: 338b to BS 7629-1: 1997 (Inc. Amd. Nos. 1 & 2), BS 6387: 1994, IEC 60331-21: 1999, IEC 60332-3-24: 2000, BS EN 50200: 2000 Class PH120, BS 8434-2: 2003 120min and BS 5839-1: 2002 Clause 26.2e
FIRESURE PLUS
Nominal csa of conductor 1.0 1.5 2.5 4.0 Core construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (Incorporating Amendments Nos. and 2) Complies Complies Complies Complies BS 6387 IEC 60331-21 IEC 60332-324 Complies Complies Complies Complies BS EN 50200 BS84342 BS 58391 LPCB Ref. No.
338b/01
Uo/U 300/500V Note 1: Note 2: Solid conductor only Stranded conductor only
January 2009
215
PART 3: SECTION 8
FIRE RESISTANT CABLES
Note 3: Note 4: Note 5: Note 6: In meeting the requirements of BS 7629-1:1997 (Incorporating Amendments Nos. 1 and 2), the FIRESURE PLUS cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS EN 50267-2-1:1999. These cables met the requirements of IEC 60331-21:1999 when tested at a temperature of 950C (which is not recognised by IEC 60331). The duration of 120min when tested in accordance with BS 8434-2:2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2e) of BS 5839-1:2002. The FIRESURE PLUS cables listed conform to BS 7629-1:1997 (Incorporating Amendments Nos. 1 and 2), met Class PH120 when tested in accordance with BS EN 50200:2000 and met a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2e of BS 5839-1:2002.
Certificate No: 663b to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 50268-2: 2000 and IEC 60331-21: 1999
216
January 2009
SECTION 8: PART
Nominal csa of 2 conductor (mm ) 6.0 10 16 25 35 50 70 95 120 150 185 240 300 Uo/U 450/750V Core Construction (see note 1) (4,5,6) One (4,5,6) One (4,5,6) One (4,5,6) One (4,5,6) One (2,6) One (2,6) One (2,6) One (2,6) One (2,6) One (2,6) One (2,6) One (2,6) One BS 6387 BS EN 50267-2-1 (Insulation & Binder tape) <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI BS EN 50268-2 IEC 60331-21 LPCB Ref. No.
Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies
Notes: 1) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. 2) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. 3) To satisfy the requirement of BS 6387, testing for C & W categories was conducted using a 20mm steel conduit as the other metallic element. 4) To satisfy the requirement of BS 6387, testing for Z category was conducted using a 20mm steel conduit as the other metallic element. 5) To satisfy the requirement of BS 6387, testing for W category was conducted using a 38mm steel conduit as the other metallic element. 6) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm steel conduit as the other metallic element.
Uo/U 600/1000 V Note: 1) In meeting the requirements of BS 7846: 2000 (Incorporating Amendments Nos. 1 & 2), the KEYSTONE Fire Resistance Armoured Cables listed met the requirements of BS 6387: 1994 Clause 11.1 Category C, W & Z.
January 2009
217
PART 3: SECTION 8
FIRE RESISTANT CABLES
Draka UK Limited
Alfreton Road, Derby DE21 4AE UK Tel: +44 (0)1332 345431 Fax: +44 (0)1332 331237 E-mail: firetuf@drakauk.com Website: www.drakauk.com
Certificate No: 361a to IEC 331:1970 and BS EN 50267-2-1:1999
218
January 2009
SECTION 8: PART
Uo/U 600/1000V Notes: 1) The Sifer cables also met IEC 331 when tested at 950C. 2 2) The Sifer 950s cables (up to and including 25mm ) also met IEC 331 when tested in conduit at 750C and 950C which is not recognised by the standard.
1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 Uo/U 450/750V
C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z
<0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI
361b/01
Notes: 1) The Firetuf Power OHLS cable also met category C, W, Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. 2) For cables with an outside diameter in excess of 20mm, the Category Z tests were conducted in accordance with guidance from the manufacturer.
361c/01
January 2009
219
PART 3: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of 2 conductor (mm ) 150/70 185/95 240/120 50/25 70/35 95/50 Uo/U 450/750V Notes: 1) The Firetuf FTPU 950 fire resistant Mifer OHLS cable also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. 2) For cable with an outside diameter of in excess of 20mm, the category Z tests were conducted in accordance with guidance from the manufacturer. Core Construction (excluding drain wire & earth) 4+ Concentric Earth 4+ Concentric Earth 4+ Concentric Earth 4+ Concentric Earth 4+ Concentric Earth 4+ Concentric Earth BS 6387 (see notes 1 & 2) C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl LPCB Ref. No.
Certificate No: 361d to BS7629-1:1997 (Incorporating Amendments Nos. 1 & 2), BS6387:1994, BS 5839-1: 2002 Clause 26.2d, BS 8434-1: 2003 30 min & BS EN 50200: 2000 Class PH30
BS 6387
BS EN 50200
BS 84341
C, W, Z C, W, Z C, W, Z
(2)
361d/01
Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the Firetuf Easystrip Multicore cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the (insulation & outer covering) when tested in accordance with BS EN 50267-2-1: 1999. 2) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002. 3) The Firetuf Easystrip Multicore cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), met Class PH30 when tested in accordance with BS EN 50200: 2000 and met a duration of 30min when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
Certificate No: 361e to BS 7629-1: 1997 (Incorporating Amendment No.1), BS 5839-1: 2002 Clause 26.2d, BS 8434-1: 2003 30min & BS EN 50200: 2000 Class PH30
Firetuf EMC
Nominal csa of 2 conductor (mm ) Core Construction (excluding drain wire & earth) 2 2 BS 7629-1 (Incorporating Amendment No.1) Complies (1) Complies
(1)
BS EN 50200
BS 8434-1
(2)
361e/01
Notes: 1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendment No.1), the Firetuf EMC cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the (insulation & outer covering) when tested in accordance with BS EN 50267-2-1: 1999 . 2) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2 d) of BS 5839-1: 2002.
220
January 2009
SECTION 8: PART
Certificate No: 361f to BS 7629-1: 1997 (Incorporating Amendment No. 1), BS 6387: 1994, BS EN 50200: 2000 Class PH120, BS 8434-2: 2003 120min and BS 5839-1: 2002 Clause 26.2e
Firetuf Plus
Nominal csa of 2 conductor (mm ) 1.5 2.5 4.0 Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendment No.1), the Firetuf Plus cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-2-1: 1999. 2) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2 e) of BS 5839-1: 2002. 3) The Firetuf Plus cables listed conform to BS 7629-1: 1997 (Incorporating Amendment No.1), met Class PH120 when tested in accordance with EN 50200: 2000 and met the 120min duration when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002. Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (Incorporating Amendment No.1) (1) Complies (1) Complies (1) Complies BS 6387 BS EN 50200 BS 8434-2
(2)
361f/01
Firetuf Powerplus
Nominal csa ofconductor (mm ) 10 (1) 120 (1) 150 (1) 16 (1) 185 (1) 2.5 1) 240 (1) 25 (1) 300 (1) 35 (1) 400 (1) 50 (1) 70 (1) 95 Uo/U 600/1000V Note: 1) Stranded conductor only
(1) 2
CoreConstructiondrainwire & earth) 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 7 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 4 4 4 4 4 4 4 4 4 4 4 4 4
BS 7346-6 (fire survival time) 120min 120min 120min 120min 120min 120min 120min 120min 120min 120min 120min 120min 120min 120min
IEC 60331-21 (see note 8) Complies Complies Complies Complies Complies Complies
January 2009
221
PART 3: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of conductor 2) (mm 25 35 50 70 95 120 150 185 240 300 400 500 630 Uo/U 600/1000V Note 1: Stranded conductor only. Note 2: Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. Note 3: These cables also met category C, W, Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. Note 4: Where a single cable is fitted in a conduit, only phase to earth voltage was applied. Note 5: To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. Note 6: To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. Note 7: To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. Note 8: The Sifer 950i cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600V. Core construction (see note 1) One One One One One One One One One One One One One BS 6387 (see notes 2-4) C,W,Z (6,7) C,W,Z (6,7) C,W,Z (6,7) C,W,Z (6,7)
IEC 60331-21 (see note 8) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies
BS EN 502672-1 <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI
IEC 60331-21 (see note 8) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies
BS EN 502672-1 <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI
222
January 2009
SECTION 8: PART
Ducab - FR
Nominal csa of 2 conductor (mm ) 1.5 2.5 4.0 6.0 10 16 25 35 Uo/U 600/1000V Notes: 1) Stranded conductor only 2) In meeting the requirements of BS 7846: 2000 (incorporating Amendments Nos. 1 & 2) Category F2, the Ducab - FR cables met the requirements for fire resistance characteristics category CWZ specified in Clause 11 of BS 6387: 1994 Core Construction (see note 1) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 (Incorporating Amendments Nos. 1 and 2) F2 F2 F2 F2 F2 F2 F2 F2 LPCB Ref. No. 781a/01
Certificate No: 781b to BS 7846: 2000 This certificate is to a withdrawn version of the BS 7846: 2000. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU)
Ducab - FR
Nominal csa of 2 conductor (mm ) 1.5 2.5 4.0 6.0 10 16 25 35 Uo/U 600/1000 V Notes: 1) Stranded conductors only 2) In meeting the requirements of BS 7846: 2000 Category F2, the Ducab - FR cables met the requirements for fire resistance characteristics category CWZ specified in Clause 11 of BS 6387: 1994 3) BS 7846: 2000 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the st CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31 March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators. Certificate 781a covers cables certified in accordance with BS 7846: 2000 (Incorporating Amendments Nos. 1 & 2) Core Construction (see Note 1) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 (see Notes 2 & 3) F2 F2 F2 F2 F2 F2 F2 F2 LPCB Ref. No. 781b/01
January 2009
223
PART 3: SECTION 8
FIRE RESISTANT CABLES
Certificate No: 781c to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 50268-2: 2000 and IEC 60331-21: 1999
Ducab - FR SC
Nominal csa of conductor 2 (mm 1.5 2.5 4.0 6.0 10 Uo/U 600/1000V Notes: 1) Stranded conductor only. 2) Clause 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. 3) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. 4) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. 5) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. 6) These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C (which is not recognised by IEC 60331-21: 1999) and at a voltage rating of 600V. Core Construction (see note 1) One One One One One BS 6387 (see notes 2 5) C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-21 <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl BS EN 502682 >60% >60% >60% >60% >60% IEC 6033121 (see note 6) Complies Complies Complies Complies Complies LPCB Ref. No. 781c/01
Ducab - FR
Nominal csa of 2 conductor (mm ) 50 70 95 120 150 185 240 300 400 Uo/U 600/1000V Notes: 1) Stranded conductors only 2) In meeting the requirements of BS 7846: 2000 Incorporating Amendments Nos. 1 & 2) Category F2, the Ducab - FR cables met the requirements for fire resistance characteristics category CWZ specified in Clause 11 of BS 6387:1994. Core Construction (see note 1) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 (Incorporating Amendments Nos. 1 and 2 F2 F2 F2 F2 F2 F2 F2 F2 F2 LPCB Ref. No. 782a/01
Certificate No: 782b to BS 7846: 2000 This certificate is to a withdrawn version of the BS 7846: 2000. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU)
224
January 2009
SECTION 8: PART
Ducab - FR
Nominal csa of 2 conductor (mm ) 50 70 95 120 150 185 240 300 400 Uo/U 600/1000 V Core Construction (see note 1) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 (see notes 2 & 3) F2 F2 F2 F2 F2 F2 F2 F2 F2 LPCB Ref. No. 782b/01
Notes: 1) Stranded conductors only 2) In meeting the requirements of BS 7846: 2000 Category F2, the Ducab - FR cables met the requirements for fire resistance characteristics category CWZ specified in Clause 11 of BS 6387: 1994 3) BS 7846: 2000 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the st CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31 March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators. Certificate 782a covers cables certified in accordance with BS 7846: 2000 (Incorporating Amendments Nos. 1 & 2)
Eland Cables
120 Highgate Studios, 53-79 Highgate Road, London NW5 1TL UK Tel: +44 (0)20 7241 8787 Fax: +44 (0)20 7241 8700 E-mail: sales@eland.co.uk Website: www.eland.co.uk
Certificate No: 568c to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000, BS 8434-1: 2003 30min and BS 5839-1: 2002 Clause 26.2d
FireForce
Nominal csa of conductor (mm) 1.0 (1) 1.5 (1) 2.5 (2) 4.0
(1)
Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4
BS 7629-1 (Incorporating Amendments Nos. 1 & 2) (3) Complies (3) Complies (3) Complies (3) Complies
BS 5839-1 Clause 26.2 Standard (5) Standard (5) Standard (5) Standard
(5)
Notes: 1) Solid and Stranded conductors. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the FireForce cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS EN 50267-2-1: 1999. 4) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2 d) of BS 5839-1: 2002. 5) The FireForce cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), met Class PH30 when tested in accordance with EN 50200: 2000 and met a duration of 30min when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
January 2009
225
PART 3: SECTION 8
FIRE RESISTANT CABLES
FIREX
Nominal csa of conductors (mm) (1) 1.0 (1) 1.5 (1) 2.5 (2) 4.0 Uo/U 300/500 V Notes: 1) Solid and stranded conductors. 2) Stranded conductor only. Core Construction 2, 3 & 2, 3 & 2, 3 & 2, 3 & 4 4 4 4 BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI LPCB Ref. No. 568a/01
FIREX-UK
Nominal csa of conductors (mm) (1) 1.0 (1) 1.5 (1) 2.5 (2) 4.0 Uo/U 300/500 V Notes: 1) Solid and stranded conductors. 2) Stranded conductor only. Core Construction 2, 3 & 2, 3 & 2, 3 & 2, 3 & 4 4 4 4 BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI LPCB Ref. No. 568a/01
Fireshield Enhanced
Nominal csa of 2 conductor (mm ) (1) 1.0 (1) 1.5 (1) 2.5 Uo/U 300/500V Notes: 1) Solid conductor only. Core construction 2&4 2&4 2 BS 8434-2 120min (2) 120min (2) 120min
(2)
226
January 2009
SECTION 8: PART
Fire Defence
Nominal csa of conductor (mm) 1.0 (1) 1.5 (1) 2.5 2) 4.0 Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), the Fire Defence cables listed met the requirements of smoke density of BS EN 50268-2:2000, fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-21:1999. 4) The duration of 30min when tested in accordance with BS 8434-1:2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1:2002. 5) The Fire Defence cables listed conform to BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), met Class PH120 when tested in accordance with BS EN 50200:2006 and met the 30min duration when tested in accordance with BS 8434-1:2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1:2002.
(1)
Core construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2
BS 7629-1 Amendments No.1 and 2) Complies (3) Complies (3) Complies (3) Complies
(3)
BS EN 50200
BS 84341
(4)
BS 5839-1 Clause 26.2 Standard (5) Standard (5) Standard (5) Standard
(5)
330h/01
January 2009
227
PART 3: SECTION 8
FIRE RESISTANT CABLES
228
January 2009
SECTION 8: PART
Nominal csa of 2 conductor (mm ) (1) 25.0 (1) 35.0 (1) 50.0 (1) 70.0 (1) 95.0 (1) 120.0 (1) 150.0 (1) 185.0 Uo/U 600/1000V Notes: 1) Stranded conductor only. 2) In meeting the requirements of BS 7846 category F2, the SEGURFOC FRA 950 cable met the requirements for fire resistance characteristics category CWZ specified in Clause 11 of BS 6387. Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 (see note 2) F2 F2 F2 F2 F2 F2 F2 F2 LPCB Ref. No.
FIRECOOL
Nominal csa of conductor 2 (mm ) 1.0 (2) 1.5 (2) 2.5 (3) 4.0 Uo/U 300/500V Notes 1) Solid conductor only 2) Solid and Stranded conductors 3) Stranded conductor only 4) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos.1 & 2), the FIRECOOL cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS EN 50267-2-1: 1999.
(1)
Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4
BS 6387
BS EN 50200
BS 84341
BS 5839-1 Clause 26.2 Standard (6) Standard (6) Standard (6) Standard
(6)
C, W, Z C, W, Z C, W, Z C, W, Z
(5)
716a/01
January 2009
229
PART 3: SECTION 8
FIRE RESISTANT CABLES
5) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2 d) of BS 5839-1: 2002. 6) The FIRECOOL cables listed conform to BS 7629-1: 1997 (Incorporating Amendments No.1 & 2), met Class PH30 when tested in accordance with BS EN 50200: 2000 and met a duration of 30min when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
Kilflam 2000
Nominal csa of 2 conductor (mm ) 1.0 (2,3) 1.5 (4) 2.5 (4) 4.0 Uo/U 300/500V Notes: 1) Solid conductor only. 2) Solid conductor at 3 & 4 cores only. 3) Stranded conductor at 2 core only. 4) Stranded conductor only. 5) In meeting the requirements of BS 7629-1:1997 (Incorporating Amendments Nos. 1 and 2), the Kilflam 2000 cables met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCI on the (outer covering, insulation and binder tape) when tested in accordance with BS EN 50267-2-1: 1999. 6) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1:2002. 7) The Kilflam 2000 cables listed conform to BS 7629-1:1997 (Incorporating Amendments Nos. 1 and 2), met Class PH30 when tested in accordance with BS EN 50200:2000 and met the 30min duration when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1:2002.
(1)
Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4
BS 7629-1 (Incorporating Amendments Nos.1 & 2) (5) Complies (5) Complies (5) Complies (5) Complies
BS EN 50200
BS 8434-1
BS 5839-1 Clause 26.2 Standard (7) Standard (7) Standard (7) Standard
(7)
(6)
408a/01
Kilflam 1000
Nominal csa of 2 conductor (mm ) 1.5 2.5 4.0 6.0 10.0 16.0 Uo/U 450/750V Notes: 1) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable only having one core. 2.) To satisfy the requirements of BS 6387, testing for C, W and Z categories was conducted using 20mm steel conduit as the other metallic element. Core Construction One One One One One One BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z LPCB Ref. No. 408b/01
230
January 2009
SECTION 8: PART
Certificate No: 408c to BS 7629-1:1997 (Inc. Amendment No.1), BS EN 50200:2000 Class PH120, BS 8434-2:2003 120min & BS 5839-1:2002 Clause 26.2e
Kilflam 3000
Nominal csa of 2 conductor (mm ) 1.0 1.5 2.5 4.0 Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1:1997 (Inc. Amd. No.1), the Kilflam 3000 cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-2-1:1999. 2) The duration of 120min when tested in accordance with BS 8434-2:2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2e) of BS 5839-1:2002. 3) The Kilflam 3000 cables listed conform to BS 7629-1:1997 (Incorporating Amendment No.1), met Class PH120 when tested in accordance with BS EN 50200:2000 and met the 120min duration when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1:2002. Core Construction 2, 3 & 2, 3 & 2, 3 & 2, 3 & 4 4 4 4 BS 7629-1 (Incorporating Amendment No. 1) (1) Complies (1) Complies (1) Complies (1) Complies BS EN 50200 BS 8434-2 BS 5839-1 Clause 26.2 Enhanced (3) Enhanced (3) Enhanced (3) Enhanced
(3)
(2)
408c/01
Kilflam 1200
Nominal csa of 2 conductor (mm ) 1.5 2.5 4.0 6.0 10.0 Uo/U 600/1000V Notes: 1) Stranded conductor only. 2) Clause 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable having only one core. 3) The Kilflam 1200 cable also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. 4) To satisfy the requirement of BS 6387, testing for C category was conducted using a 20mm steel conduit as the other metallic element. 5) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm steel conduit as the other metallic element. 6) To satisfy the requirement of BS 6387, testing for W and Z categories was conducted using a 20mm steel conduit as the other metallic element. 7) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. Core Construction (see note 1) (4,6) One (4,6) One (4,6) One (5,6) One (5,6) One BS 6387 (see notes 2, 3 & 7) C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl LPCB Ref. No.
408d/01
Certificate No: 408e to BS 7629-1: 1997, BS EN 50200: 2000, BS 8434-1: 2003 30min and BS 5839-1: 2002 Clause 26.2d
Kilflam 2000
Nominal csa of 2 conductor (mm 1.0 (2,3) 1.5 (4) 2.5 (4) 4.0
(1)
Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4
BS 7629-1 (see note 8) Complies (5) Complies (5) Complies (5) Complies
(5)
BS EN 50200
BS 8434-1
BS 5839-1 Clause 26.2 Standard (7) Standard (7) Standard (7) Standard
(7)
(6)
408e/01
January 2009
231
PART 3: SECTION 8
FIRE RESISTANT CABLES
Uo/U 300/500V Notes: 1) Solid conductor only 2) Solid conductor at 3 & 4 cores only. 3) Stranded conductor at 2 core only. 4) Stranded conductor only 5) In meeting the requirements of BS 7629-1: 1997, the Kilflam 2000 cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387 1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-2-1: 1999. 6) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002. 7) The Kilflam 2000 cables listed conform to BS 7629-1: 1997, met Class PH30 when tested in accordance with BS EN 50200: 2000 and met the 30min duration when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002. 8) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the st CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31 March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators. Certificate 408e covers cables certified in accordance with BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2)
Fumeguard FR
Nominal csa of 2 conductors (mm 1.5 2.5 4.0 6.0 10.0 16.0 Core construction One One One One One One BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z LPCB Ref. No. 408b/01
Uo/U450/750V Notes: 1) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable having only one core. 2) To satisfy the requirement of BS 6387, testing for C, W, and Z categories was conducted using 20mm steel conduit as the other metallic element.
Jayflame
Nominal csa of conductor 2 (mm ) 1.0 1.5 2.5 4.0 Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2 BS 7629-1 (Incorporating Amendments No. 1 & 2) Complies Complies Complies Complies
(3)
BS EN 50200
BS 84341
(3)
(3)
(3)
30min 30min
(4)
682a/01
(4)
(5)
30min
(4)
Standard
(5)
30min
(4)
Standard
(5)
232
January 2009
SECTION 8: PART
Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), the Jayflame cables listed met the requirements of smoke density of BS EN 50268-2:2000, fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-21:1999. 4) The duration of 30min when tested in accordance with BS 8434-1:2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1:2002. 5) The Jayflame cables listed conform to BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), met Class PH120 when tested in accordance with BS EN 50200:2006 and met the 30min duration when tested in accordance with BS 8434-1:2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1:2002.
Certificate No: 682b to BS 7629-1: 1997 (Incorporating Amendment No.1), BS EN 50200:2000 Class PH120, BS 8434-2: 2003 120min, BS 6387: 1994 and BS 5839-1: 2002 Clause 26.2e
Jayflame Plus
csa of conductor 2 (mm 1.0 1.5 2.5 Core Construction (excluding drain wire and earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (Incorporating Amendments Nos. 1 & 2) (2) Complies Complies Complies
(2)
(2)
Uo/U 300/500V Notes: 1) Solid conductor only 2) In meeting the requirements of BS 7629-1:1997 (Incorporating Amendments Nos.1 & 2), the Jayflame Plus cables listed met the requirements of smoke density of BS EN 50268-2:2000 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-2-1:1999. 3) The duration of 120min when tested in accordance with BS 8434-2:2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2e) of BS 5839-1:2002. 4) The Jayflame Plus cables listed conform to BS 7629-1:1997 (Incorporating Amendments Nos.1 & 2), met Class PH120 when tested in accordance with BS EN 50200:2000 and met a duration of 120min when tested in accordance with BS 8434-2:2003 and hence met the requirements for an enhanced fire resistant cable as described in clause 26.2 of BS 5839-1:2002.
Firepro
Nominal csa of conductor (mm) (1) 1.5 (1) 16 (1) 10 (1) 2.5 (1) 4.0 (1) 6.0 Core construction One (4, 5) One (4, 5) One (3) One (3) One (3) One
(3)
BS EN 50267-2-1 covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl
January 2009
233
PART 3: SECTION 8
FIRE RESISTANT CABLES
Uo/U 450/750V Notes: 1) Stranded conductor only 2) Clause 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable having only one core. 3) To satisfy the requirement of BS 6387, testing for C, W & Z categories were conducted using a 20mm stainless steel conduit as the other metallic element. 4) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. 5) To satisfy the requirement of BS 6387, testing for W & Z categories were conducted using a 20mm stainless steel conduit as the other metallic element. 6) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.
234
January 2009
SECTION 8: PART
C, W, Z C, W, Z C, W, Z
253a/01
Certificate No: 253f to BS 7629-1: 1997 (Inc. Amd. No.1), BS 6387: 1994, BS EN 50200: 2000 Class PH30, BS 8434-1: 2003 30min and BS 5839-1: 2002 Clause 26.2d
Alsecure-NX200
Nominal csa of conductor 2 (mm ) 1.0 (1) 1.5 (1) 2.5 (2) 4.0 Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendment No.1), the Alsecure-NX200 cables listed met the requirements of smoke density of BS EN 50268-: 2000 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS EN 50267-2-1: 1999.
(1)
Core Construction (excluding drain wire & earth) 2,3 & 4 2,3 & 4 2,3 & 4 2,3 & 4
BS 7629-1 (Incorporating Amendment No.1) Complies (3) Complies (3) Complies (3) Complies
(3)
BS 6387
BS EN 50200
BS 84341
BS 5839-1 Clause 26.2 Standard (5) Standard (5) Standard (5) Standard
(5)
(4)
253f/01
January 2009
235
PART 3: SECTION 8
FIRE RESISTANT CABLES
4) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2 d) of BS 5839-1: 2002. 5) The Alsecure-NX200 cables listed conform to BS 7629-1: 1997 (Incorporating Amendment No.1), met Class PH30 when tested in accordance with EN 50200: 2000 and met a duration of 30min when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
Certificate No: 253g to BS 7629-1: 1997 (Inc. Amd. Nos. 1 and 2), BS 6387: 1994, BS EN 50200: 2000 Class PH120, BS 8434-2: 2003 120min and BS 5839-1: 2002 Clause 26.2e
Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4
BS 6387
BS EN 50200
BS 84342
(1)
(2)
(1)
(2)
(3)
253g/01
(3)
Enhanced
(4)
(3)
Enhanced
(4)
Uo/U 300/500V Notes: 1) Solid conductor only. 2) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), the ALSECURE NX 200 PLUS cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS EN 50267-2-1: 1999. 3) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2 e) of BS 5839-1: 2002. 4) The ALSECURE NX 200 PLUS cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), met Class PH120 when tested in accordance with BS EN 50200: 2000 and met a duration of 120min when tested in accordance with BS 84342: 2003 and hence met the requirements for an Enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
CQR FireBrand 30
Nominal csa of Conductor 2 (mm ) 1.0 (2,3) 1.5 (4) 2.5 (4) 4.0 Uo/U 300/500V Notes: 1) Solid conductor only 2) Solid conductor at 3 & 4 cores only. 3) Stranded conductor at 2 core only. 4) Stranded conductor only 5) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), the CQR FireBrand 30 cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-2-1: 1999.
(1)
Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4
BS 7629-1 (Incorporating Amendments Nos. 1 and 2) (5) Complies (5) Complies (5) Complies (5) Complies
BS EN 50200
BS 84341
(6)
BS 5839-1 Clause 26.2 Standard (7) Standard (7) Standard (7) Standard
(7)
815a/01
236
January 2009
SECTION 8: PART
FP200 Flex
Nominal csa of 2 conductor (mm ) 1.0 1.5 2.5 Uo/U 300/500V Note: 1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the FP200 Flex cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-2-1: 1999. Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (Incorporating Amendments Nos. 1 and 2) (1) Complies (1) Complies (1) Complies LPCB Ref. No. 077a/03
January 2009
237
PART 3: SECTION 8
FIRE RESISTANT CABLES
Uo/U 450/750V Note: 1) The FP300 LSOH cable also met Category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.
Certificate No: 077c to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999
238
January 2009
SECTION 8: PART
Nominal csa of 2 conductor (mm ) 95 120 150 185 240 300 400 500 630 Uo/U 450/750V Notes: 1) Testing was conducted using 20mm steel conduit. 2) To satisfy the requirement of BS 6387 the conduit was considered as the other metallic element. 3) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. 4) Only a single cable is fitted in conduit, hence only phase to earth voltage was applied. O 5) Testing to IEC 60331 was conducted at voltage rating of 600/1000V and at 95 C which is not recognised by the standard. Core Construction One One One One One One One One One BS 6387 (see notes 1 - 4) C, W, Z C C BS EN 50267-2-1 (outer covering) IEC 60331-21 (see Note 5) Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No.
FP150 LS0H
Nominal csa of 2 conductor (mm ) 1.0 1.5 2.5 Uo/U 300/500V Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl BS EN 50268-2 >60% >60% >60% LPCB Ref. No. 077d/01
Certificate No: 077e to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999
January 2009
239
PART 3: SECTION 8
FIRE RESISTANT CABLES
4) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm steel conduit as the other metallic element. 5) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. 6) Only clause 10 of BS 6387 was conducted. o 7) Testing to IEC 60331 was conducted at voltage rating of 600/1000V and at 950 C which is not recognised by the standard
Certificate No: 077f to BS 7629-1: 1997 (Inc. Amd. Nos. 1 & 2) and BS 5839-1:2002 Clause 26.2d
BS EN 50200
(1)
Class PH30 Class PH30 & PH60 Class PH30 & PH60 Class PH30 & PH60
Standard
(2)
Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the FP200 Gold LSOH cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11
240
January 2009
SECTION 8: PART
of BS 6387: 1994 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS EN 50267-2-1: 1999. 2) The FP200 Gold LSOH cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), met Class PH30 when tested in accordance with BS EN 50200: 2000 and met the requirements of the additional fire, mechanical shock and water tests described in Clause 26.2 d) of BS 5839-1: 2002 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
Certificate No: 077g to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200:2000 Class PH120, BS 84342:2003 120min & BS 5839-1:2002 Clause 26.2e
FP Plus
Nominal csa of 2 conductor (mm ) 1.0 1.5 2.5 Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 1997 (Inc. Amd. Nos. 1 & 2), the FP Plus cables listed met the requirements of smoke density of BS EN 50268-2:2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (binder tape & outer covering) when tested in accordance with BS EN 50267-2-1: 1999. 2) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2 e) of BS 5839-1: 2002. 3) The FP Plus cables listed conform to BS 7629-1: 1997, meet Class PH120 when tested in accordance with EN 50200: 2000 and meet a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence meet the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002. Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (Incorporating Amendment Nos.1 & 2) (1) Complies (1) Complies (1) Complies BS EN 50200 BS 8434-2 BS 5839-1 Clause 26.2 Enhanced (3) Enhanced (3) Enhanced
(3)
077g/01
Certificate No: 077h to BS 7629-1:1997 (Inc.Amd.No.1), BS EN 50200:2000 Class PH120, BS 8434-2:2003 120min BS 5839-1: Clause 26.2e
FP Plus Flex
Nominal csa of conductor 2 (mm ) Core Construction (excluding drain wire & earth) 2,3 & 4 2,3 & 4 2,3 & 4 2,3 & 4 BS 7629-1 (Incorporating Amendment No.1)
(1)
BS EN 50200
BS 84342
(1)
(1)
(1)
(2)
Enhanced Enhanced
077h/01
(2)
(3)
(2)
Enhanced
(3)
120min
(2)
Enhanced
(3)
Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendment No.1), the FP Plus Flex cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-2-1: 1999. 2) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2 e) of BS 5839-1: 2002. 3) The FP Plus Flex cables listed conform to BS 7629-1: 1997 (Incorporating Amendment No.1), met Class PH120 when tested in accordance with EN 50200: 2000 and met a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
Certificate No: 077j to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU).
January 2009
241
PART 3: SECTION 8
FIRE RESISTANT CABLES FP200 Gold LSOH
Nominal csa of 2 conductor (mm ) 1.0 1.5 2.5 Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 1997, the FP200 Gold LSOH cables listed met the requirements of smoke density of BS 7622-2: 1993, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS 6425-1: 1990. 2) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the st CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31 March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being. to satisfy the requirements of these regulators. Certificate 077a covers cables certified in accordance with BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2) Core Construction (excluding drain wire & earth) 7 7, 12 & 19 7 & 12 BS 7629-1 (see Note 2) Complies (1) Complies (1) Complies
(1)
077j/01
Certificate No: 077j to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU).
FP200 Flex
Nominal csa of 2 conductor (mm ) 1.0 1.5 2.5 Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 1997, the FP200 Flex cables listed met the requirements of smoke density of BS 7622-2: 1993, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS 6425-1: 1990. 2) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with st the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31 March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators. Certificate 077a covers cables certified in accordance with BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2) Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (see Note 2) Complies (1) Complies (1) Complies
(1)
Certificate No: 077k to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU), BS EN 50200: 2000 & BS 5839-1:2002 Clause 26.2d
BS EN 50200
BS 5839-1 Clause 26.2 Standard (2) Standard (2) Standard (2) Standard
(2)
Class PH30 Class PH30 & PH60 Class PH30 & PH60 Class PH30 & PH60
077k/01
242
January 2009
SECTION 8: PART
1) In meeting the requirements of BS 7629-1: 1997, the FP200 Gold LSOH cables listed met the requirements of smoke density of BS 7622-2: 1993, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS 6425-1: 1990. 2) The FP200 Gold LSOH cables listed conform to BS 7629-1: 1997, met Class PH30 when tested in accordance with BS EN 50200: 2000 and met the requirements of the additional fire, mechanical shock and water tests described in Clause 26.2 d) of BS 5839-1: 2002 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002. 3) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on st 31 March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators. Certificate 077f covers cables certified in accordance with BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2)
FP Plus
Nominal csa of conductor 2 (mm 1.5 2.5 Core Construction (excluding drain wire & earth) 2 2 BS 7629-1 (Incoporating Amendments Nos. 1 & 2) (2) Complies Complies
(2)
Uo/U 300/500V Notes: 1) Solid conductor only 2) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the FP Plus cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-2-1: 1999. 3) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2e) of BS 5839-1: 2002. 4) The FP Plus cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), met Class PH120 when tested in accordance with BS EN 50200: 2000 and met the 120min duration when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
Certificate No: 077m to BS 7346-6: 2005, BS EN 50267-2-1: 1999 and BS 61034-2: 2005
FP600
Nominal csa of conductor 2 (mm ) (1) 10 16 (1) 25 (1) 35 (1) 50 (1) 70 Uo/U 600/1000V Note: 1) Stranded conductor only. 2) In achieving 120min fire survival time in accordance with BS 7346-6: 2005, the FP600 cables listed also achieved a 120min fire survival time in accordance with BS 6491:2008. The test method given in BS 8491: 2008 is technically identical to the test method given in BS 7346: 2005 Annex B.
(1)
Core construction earth wire) 2, 3 & 4 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 4 4 4 4 4
BS 8491 (fire survival time see note 2) 120min 120min 120min 120min 120min 120min
BS EN 50267-21 <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl
January 2009
243
PART 3: SECTION 8
FIRE RESISTANT CABLES
Certificate No: 517c to BS 7346-6: 2005, BS 8491: 2008, BS EN 50267-2-1: 1999 and BS EN 61034-2: 2005
244
January 2009
SECTION 8: PART
FP600S
Nominal csa of conductor (mm 2 ) 120 150 185 240 300 400 70 (1) 95
(1)
BS 7346-6 (fire survival time) 120min 120min 120min 120min 120min 120min 120min 120min
BS 8491 (fire survival time see note 2) 120min 120min 120min 120min 120min 120min 120min 120min
BS EN 502672-1 <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl
Uo/U 600/1000V Notes: 1) Stranded conductor only. 2) In achieving a 120min fire survival time in accordance with BS 7346-6: 2005, the FP600S cables listed also achieved a 120min fire survival time in accordance with BS 8491: 2008. The test method given in BS 8491: 2008 is technically identical to the test method given in BS 7346-6: 2005, Annex B.
January 2009
245
PART 3: SECTION 8
FIRE RESISTANT CABLES FIRESTOP FS-90 Multicore Cable
Nominal csa of 2 conductor (mm ) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 Uo/U 450/750 V Notes: 1) Approved for CEC04QMR series construction. 2) Approved for REC04QMR series construction. Core Construction (See notes 1, 2) (1) 4 (1) 4 (1) 4 (1) 4 (1) 4 (1) 4 (1) 4 (1) 4 (1)(2) 4 (1)(2) 4 (1)(2) 4 (1)(2) 4 (1)(2) 4 (1)(2) 4 (1)(2) 4 (1)(2) 4 (2) 4 BS 6387 BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl LPCB Ref. No.
C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z
422b/01
RAMCRO S.p.A
V. Tanaro, 19, 20010 Villastanza di Parabiago, Milan, Italy Tel: +39 0331 406550 Fax: +39 0331 406559
Certificate No: 568a to BS 6387:1994 and BS EN 50267-2-1:1999
Ramfirecro-F3
Nominal csa of 2 conductor (mm ) (1) 1.0 (1) 1.5 (1) 2.5 (2) 4.0 Uo/U 300/500 V Notes: 1) Solid and stranded conductors. 2) Stranded conductor only. Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI LPCB Ref. No. 568a/01
Certificate No: 568b to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU), BS EN 50200: 2000 Class PH30, BS 8434-1:2003 30min & BS 5839-1:2002 Clause 26.2d
Ramfirecro-F3 Standard
Nominal csa of conductor (mm) 1.0 (1) 1.5 (1) 2.5 (2) 4.0 Uo/U 300/500V
(1)
Core Construction (excluding drain wire & earth) 2 ,3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4
BS 7629-1 (see note 6) Complies (3) Complies (3) Complies (3) Complies
(3)
BS EN 50200
BS 8434-1
BS 5839-1 Clause 26.2 Standard (5) Standard (5) Standard (5) Standard
(5)
(4)
568b/01
246
January 2009
SECTION 8: PART
Certificate No: 568c to BS 7629-1:1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000, BS 8434-1: 2003 30min and BS 5839-1: 2002 Clause 26.2d
Ramfirecro-F3 Standard
Nominal csa of conductor (mm) 1.0 (1) 1.5 (1) 2.5 (2) 4.0 Uo/U 300/500V Notes: 1) Solid and Stranded conductors. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the Ramfirecro-F3 Standard cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS EN 50267-2-1: 1999. 4) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2 d) of BS 5839-1: 2002. 5) The Ramfirecro-F3 Standard cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), met Class PH30 when tested in accordance with EN 50200: 2000 and met a duration of 30min when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
(1)
Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4
BS 7629-1 (Incorporating Amendments Nos. 1 and 2) Complies (3) Complies (3) Complies (3) Complies
(3)
BS EN 50200
BS 84341
BS 5839-1 Clause 26.2 Standard (5) Standard (5) Standard (5) Standard
(5)
(4)
568c/01
814c/01
January 2009
247
PART 3: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of conductor 2 (mm (1) 10 (1) 16 25 35 50 70 95 120 150 185 240 300 400 500 Uo/U 600/1000V Notes: 1) Stranded conductor only 2) Clause 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. 3) To satisfy the requirement of BS 6387, testing for C, W & Z categories were conducted using a 20mm stainless steel conduit as the other metallic element. 4) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. 5) To satisfy the requirement of BS 6387, testing for W & Z categories were conducted using a 20mm stainless steel conduit as the other metallic element. 6) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. 7) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. 8) These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C (which is not recognised by IEC 60331-21: 1999) and at a voltage rating of 600V. Core Construction One One One One One One One One One One One One One One BS 6387 (See Notes 2, 6 & 7) C, W, Z (4,5) C, W, Z (4,5) C, W, Z (3) C, W, Z (3) C, W, Z (3) C, W, Z (3) C, W, Z (4) C (4) C (4) C (4) C (4) C (4) C (4,5)
BS EN 50267-2-1 (outer covering) <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl
IEC 60331-21 (See Note 8) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies
Certificate No: 814a to BS 7629-1: 1997 (Inc. Amd. Nos. 1 and 2), BS 6387: 1994, BS EN 50200: 2000 Class PH30, BS 8434-1: 2003 30min and BS 5839-1: 2002 Clause 26.2
FLAME-X 950
Nominal csa of conductor (mm) Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (Incorporating Amendments Nos. 1 & 2) Complies Complies Complies Complies
(3)
BS 6387
BS EN 50200
BS 8434-1
1.0 1.5
(1)
(1)
(3)
2.5
(1)
(3)
4.0
(2)
(3)
30min 30min
(4)
814a/01
(4)
(5)
30min
(4)
Standard
(5)
30min
(4)
Standard
(5)
Uo/U 300/500V Notes: 1) Solid conductor only 2) Stranded conductor only 3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), the FLAME-X 950 cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS EN 50267-2-1: 1999. 4) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002. 5) The FLAME-X 950 cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), met Class PH30 when tested in accordance with BS EN 50200: 2000 and met a duration of 30min when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
248
January 2009
SECTION 8: PART
Certificate No: 814b to BS 7629-1: 1997 (Inc. Amd. Nos. 1 and 2), BS 6387: 1994, BS EN 50200: 2000 Class PH120, BS 8434-2: 2003 120min and BS 5839-1: 2002 Clause 26.2
Core Construction drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4
BS 7629-1 (Incorporating Amendments Nos. 1 and 2) (3) Complies Complies Complies Complies
(3)
BS6387
(1)
(4)
(5)
2.5 4.0
(1)
(3)
(4)
(5)
(2)
(3)
(4)
(5)
Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), the FLAME-X 950 Enhanced cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS EN 50267-2-1: 1999. 4) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2e) of BS 5839-1: 2002. 5) The FLAME-X 950 Enhanced cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), met Class PH120 when tested in accordance with BS EN 50200: 2000 and met a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
Core Construction 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2, 3 & 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
BS 7846: 2000 (Incorporating Amendments Nos. 1 and 2) F2 (2) F2 (2) F2 (2) F2 (2) F2 (2) F2 (2) F2 (2) F2 (2) F2 (2) F2 (2) F2 (2) F2 (2) F2 (2) F2 (2) F2 (2) F2
January 2009
249
PART 3: SECTION 8
FIRE RESISTANT CABLES
222a/01
Uo/U 300/500V Notes: 1) Solid conductor only 2) Stranded conductor only 3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), the FIRE-safe TW950 Fire Resistant Cables listed met the requirements of smoke density of BS 7622-2: 1993, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS 6425-1: 1990. 4) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002. 5) The FIRE-safe TW950 Fire Resistant Cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), met Class PH30 when tested in accordance with BS EN 50200: 2000 and met the 30min duration when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
Certificate No: 222b to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000 Class PH120, BS 8434-2: 2003 120min & BS 5839-1: 2002 Clause 26.2e
Firesafe Enhanced
Nominal csa of conductor 2 (mm ) 1.0 1.5 2.5 4.0
(1)
Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4
BS EN 50200
BS 84342
(1)
(3)
(2)
(3)
(2)
(3)
(4)
222b/01
(4)
Enhanced
(5)
(4)
Enhanced
(5)
(4)
Enhanced
(5)
Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos.1 & 2), the Firesafe Enhanced cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and
250
January 2009
SECTION 8: PART
Certificate No: 841b to BS EN 60702-1:2002, BS 6387:1994, BS EN 50200:2000 Class PH120, BS 8434-2:2003, BS 5839-1:2002 Clause 26.2e and BS EN 50267-2-1:1999
BS 5839-1 (outer covering) (4) Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced
(4)
(3)
(4)
(3)
(4)
(3)
(4)
(3)
(4)
(3)
(4)
Uo/U 450/750V Notes: 1) Solid conductor only. 2) The above cables are certified in served construction only. 3) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2e) of BS 5839-1: 2002.
January 2009
251
PART 3: SECTION 8
FIRE RESISTANT CABLES
4) The Pyrotenax Pyro MI Served Mineral Insulated Cables (Heavy Duty) listed conform to BS EN 60702-1: 2002, met Class PH120 when tested in accordance with BS EN 50200: 2000 and met a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an Enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
252
January 2009
SECTION 8: PART
Pyrotenax Bare Mineral Insulated Cable (heavy duty)
Nominal csa of 2 conductor (mm ) 1.5 2.5 4.0 6.0 10 16 25 Uo/U 450/750V Note: 1) The above range is certified in bare construction only. Core Construction (see note 1) 2, 3, 4, 7, 12 & 19 2, 3, 4, 7 & 12 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 BS EN 60702-1 Complies Complies Complies Complies Complies Complies Complies BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI LPCB Ref. No. 676a/03
January 2009
253
PART 3: SECTION 8
FIRE RESISTANT CABLES
1) The above range is certified in bare construction only.
Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies
C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z
427a/02
Certificate No: 063f/01 to BS EN 60702-1:2002, BS 6387:1994, BS EN 50200:2000, BS 8434-2:2003 120min, BS 5839-1:2002 Clause 26.2e and BS EN 50267-2-1:1999
BS EN 50257-2-1 <0.5%HCI
254
January 2009
SECTION 8: PART
Nominal csa of conductor 2 (mm ) 1.0 1.5T 1.5 2.5T 2.5 4.0 Core Construction (see note 3) 2, 3, 4 & 7 2, 3, 4 2, 3, 4 & 7 2, 3, 4 2, 3, 4 & 7 2 BS EN 60702-1 Complies Complies Complies Complies Complies Complies BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50200 Class PH120 Class PH120 Class PH120 Class PH120 Class PH120 Class PH120 BS 84342 120min 120min 120min 120min 120min 120min
(1)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
Uo=500V T = Twisted light duty Notes: 1) The duration of 120min when tested in accordance with BS 8434-2:2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2 e) of BS 5839-1:2002. 2) The served Pyrotenax MI cable listed conform to BS EN 60702-1:2002, meet Class PH120 when tested in accordance with BS EN 50200:2000 and meet the requirements for the additional fire, mechanical shock and water test described in Clause 26.2 e) of BS 5839-1:2002, and hence meet the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1:2002. 3) The above range is certified in served construction only.
Certificate No: 063f/02 to BS EN 60702-1:2002, BS 6387:1994, BS EN 50200:2000, BS 8434-2:2003, BS 5839-1:2002 and BS EN 50267-2-1:1999
BS 5839-1 Clause 26.2 Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced
(2)
BS EN 50267-2-1 <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
January 2009
255
PART 3: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of conductor 2 (mm ) 400 Core Construction (see note 3) One BS EN 60702-1 Complies BS 6387 C, W, Z BS EN 50200 Class PH120 BS 84342 120min
(1)
BS EN 50267-2-1 <0.5%HCI
Uo 750V Notes: 1) The duration of 120min when tested in accordance with BS 8434-2:2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2 e) of BS 5839-1:2002. 2) The served Pyrotenax MI cable listed conform to BS EN 60702-1:2002, meet Class PH120 when tested in accordance with BS EN 50200:2000 and meet the requirements for the additional fire, mechanical shock and water test described in Clause 26.2 e) of BS 5839-1:2002, and hence meet the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1:2002. 3) The above range is certified in served construction only.
Certificate No: 063f/03 to BS EN 60702-1:2002, BS 6387:1994, BS EN 50200:2000, BS 8434-2:2003, BS 5839-1:2002 and BS EN 50267-2-1:1999
BS 5839-1 Clause 26.2 Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
Uo 750V Notes: 1) The duration of 120min when tested in accordance with BS 8434-2:2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2 e) of BS 5839-1:2002. 2) The served Pyrotenax MI cable listed conform to BS EN 60702-1:2002, meet Class PH120 when tested in accordance with BS EN 50200:2000 and meet the requirements for the additional fire, mechanical shock and water test described in Clause 26.2 e) of BS 5839-1:2002, and hence meet the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 58391:2002. 3) The above range is certified in served construction only.
Certificate No: 063c to BS 7629-1:1997 (Incorporating Amendment No.1), BS EN 50200:2000 Class PH30 & BS 5839-1:2002d
Pyro S
Nominal csa of conductor (mm) (1) 1.0 1.5
(2,3)
Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4
BS 7629-1 (Incorporating Amendment Nos.1 and 2) (5) Complies Complies Complies Complies
(5)
(6)
(7)
2.5
(4)
(5)
30min
(6)
Standard
(7)
4.0
(4)
(5)
30min
(6)
Standard
(7)
256
January 2009
SECTION 8: PART
Uo/U 300/500V Notes: 1) Solid conductor only. 2) Solid conductor at 3 & 4 cores only. 3) Stranded conductor at 2 core only. 4) Stranded conductor only. 5) In meeting the requirements of BS 7629-1:1997 (Incorporating Amendments Nos. 1 and 2), the Pyro S cables met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCI on the (outer covering, insulation and binder tape) when tested in accordance with BS EN 50267-2-1: 1999. 6) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1:2002. 7) The Pyro S cables listed conform to BS 7629-1:1997 (Incorporating Amendments Nos. 1 and 2), met Class PH30 when tested in accordance with BS EN 50200:2000 and met the 30min duration when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1:2002.
Firetrax Gold
Nominal csaof 2 conductor ) 1.0 1.5 2.5 4.0
(1)
(1)
(4)
(5)
(1)
(3)
(4)
(5)
(2)
(3)
(4)
(5)
Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), the Firetrax Gold cables listed met the requirements of smoke density of BS EN 50268-2:2000, fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-21:1999. 4) The duration of 30min when tested in accordance with BS 8434-1:2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1:2002. 5) The Firetrax Gold cables listed conform to BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), met Class PH120 when tested in accordance with BS EN 50200:2006 and met the 30min duration when tested in accordance with BS 8434-1:2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1:2002.
Certificate No: 682b-(cl-2) to BS 7629-1:1997 (Incorporating Amendments Nos. 1 and 2), BS EN 50200:2000 Class PH120, BS 8434-2:2003 120min and BS 5839-1:2002 Clause 26.2
Firetrax Plus
Nominal csa of conductor (mm) 1.0 Core construction (excluding drain wire & earth) 2, 3 & 4 BS 7629-1 (Incorporating Amendments Nos. 1 and 2) (2) Complies BS 6387 C, W, Z BS EN 50200 Class PH120 BS 84342 120min
(3)
BS 5839-1
Enhanced
(4)
January 2009
257
PART 3: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of conductor (mm) 1.5 2.5 Core construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 BS 7629-1 (Incorporating Amendments Nos. 1 and 2) (2) Complies Complies
(2)
BS 6387 C, W, Z C, W, Z
BS 5839-1
Enhanced Enhanced
(4)
(3)
(4)
Uo/U 300/500V Note 1: Solid conductor only Note 2: Note 3: Note 4: In meeting the requirements of BS 7629-1:1997 (Incorporating Amendments Nos. 1 and 2), the Firetrax Plus cables listed met the requirements of smoke density of BS EN 50268-2:2000 and achieved less than 0.5%HCl on the (outer covering & insulation) when tested in accordance with BS EN 50267-2-1:1999. The duration of 120min when tested in accordance with BS 8434-2:2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2 e) of BS 5839-1:2002. The Firetrax Plus cables listed conform to BS 7629-1:1997 (Incorporating Amendments Nos. 1 and 2), met Class PH120 when tested in accordance with BS EN 50200:2000 and met a duration of 120min when tested in accordance with BS 8434-2:2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1:2002.
Ventcroft Limited
Goddard Road, Astmoor Industrial Estate, Runcorn, Cheshire WA7 1NQ UK Tel: +44 (0)1928 581098 Fax: +44 (0)1928 581099 E-mail: sales@ventcroft.co.uk Website: www.ventcroft.co.uk
Certificate No: 682a to BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), BS EN 50200: 2000 Class PH30, BS 84341:2003 30min & BS 5839-1:2002 Clause 26.2d
NoBurn Platinum
Nominal csa of conductor 2 (mm ) (1) 1.0 1.5
(1)
Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2
BS EN 50200
BS 84342
26.2
(3)
2.5 4.0
(1)
(3)
(2)
(3)
(4)
682a/01
(4)
(5)
(4)
(5)
120min
(4)
(5)
Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), the NoBurn Platinum cables listed met the requirements of smoke density of BS EN 50268-2:2000, fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-21:1999. 4) The duration of 30min when tested in accordance with BS 8434-1:2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1:2002. 5) The NoBurn Platinum cables listed conform to BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), met Class PH120 when tested in accordance with BS EN 50200:2006 and met the 30min duration when tested in accordance with BS 8434-1:2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1:2002.
Certificate No: 682b to BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), BS 6387:1994, BS EN 50200:2000 Class PH120, BS 8434-2: 2003 120min & BS 5839-1:2002 Clause 26.2e
258
January 2009
SECTION 8: PART
NoBurn Diamond
Nominal csa of conductor 2 (mm ) 1.0 1.5 2.5 Core Construction (excluding drain wire & earth) 2, 3 & 4 2,3 & 4 2,3 & 4 BS 7629-1 (Incorporating Amendment Nos.1 and 2) Complies Complies Complies BS 6387 BS EN 50200 BS 84342 BS 5839-1 Clause 26.2 Enhanced Enhanced
(4)
120min 120min
(3)
682b/01
(3)
(4)
120min
(3)
Enhanced
(4)
Uo/U 300/500V Notes: 1) Solid conductor only. 2) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos.1 and 2), the NoBurn Diamond cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the (outer covering & insulation) when tested in accordance with BS EN 50267-2-1: 1999. 3) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2 e) of BS 5839-1: 2002. 4) The NoBurn Diamond cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos.1 and 2), met Class PH120 when tested in accordance with EN 50200: 2000 and met a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.
Core Construction 2 2, 3 & 2, 3 & 2, 3 & 2, 3 & 2 2, 3 & 2, 3 & 2 2 2, 3 & 2, 3 & 2 4 4 4 4 4 4 4 4
BS EN 607021 Complies (3) Complies (3) Complies (3) Complies (3) Complies (3) Complies (3) Complies (3) Complies (3) Complies (3) Complies (3) Complies (3) Complies (3) Complies
(3)
BS EN 50200 ClassPH120 ClassPH120 ClassPH120 ClassPH120 ClassPH120 ClassPH120 ClassPH120 ClassPH120 ClassPH120 ClassPH120 ClassPH120 ClassPH120 ClassPH120
BS 8434-2 Clause 26.2 (4) 120min (4) 120min (4) 120min (4) 120min (4) 120min (4) 120min (4) 120min (4) 120min (4) 120min (4) 120min (4) 120min (4) 120min (4) 120min
BS 5839-1 Clause 26.2 (5) Enhanced (5) Enhanced (5) Enhanced (5) Enhanced (5) Enhanced (5) Enhanced (5) Enhanced (5) Enhanced (5) Enhanced (5) Enhanced (5) Enhanced (5) Enhanced (5) Enhanced
January 2009
259
PART 3: SECTION 8
FIRE RESISTANT CABLES
260
January 2009
SECTION 9: PART
This section lists cables that are certificated by LPCB as complying with NFPA 262 Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-Handling Spaces. NFPA 262 presents a test procedure for evaluating the potential for fire spread along cables and wires housed in a plenum or other environmental space. Notes: 1) Since LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.
January 2009
261
PART 3: SECTION 10
ALARM RECEIVING CENTRES This section lists Alarm Receiving Centres approved to LPS 1020 Requirements for Alarm Receiving Centres and those certified to the requirements of BS 5979 Code of Practice for Remote Centres Receiving Signals from Security Systems. The Fire Services 'Model Agreement' between the Fire and Rescue authorities and users of remotely monitored fire alarm systems calls for third party certification of both the installer and the Alarm Receiving Centre (ARC). The LPCB approval scheme based on the criteria of LPS 1020 when used in conjunction with BS 5979 provides the means to achieve the alarm receiving centre requirement of the model agreement. Third party certification of the installer can be achieved via the LPCBs scheme for installers based, on the requirements of LPS 1014 Requirements for certificated fire detection and alarm systems firms. For further details of this agreement see the CFOA website. Since the Alarm receiving centres must have links to the appropriate fire brigade mobilisation centres, the list includes details of the fire authority areas for which they are approved.
262
January 2009
Approved fire authority areas of operation: Avon, Bedfordshire, Berkshire, Cambridgeshire, Cheshire, Clwyd, Cumbria, Derbyshire, Devon, Dorset, Essex, Gloucestershire, Hampshire, Hereford & Worcester, Humberside, Lancashire, Leicestershire, Lincolnshire, London, Greater Manchester, Merseyside, Norfolk, Northamptonshire, Northern Ireland, Nottinghamshire, North Yorkshire, Shropshire, South Yorkshire, Staffordshire, Suffolk, Surrey, Tyne and Wear Warwickshire, West Glamorgan, West Midlands, West Yorkshire, Strathclyde.
January 2009
263
PART 3: SECTION 11
ALARM TRANSMISSION AND FAULT MONITORING EQUIPMENT AND SIGNALLING SYSTEMS Introduction This section of the Red Book lists alarm transmission and fault routing equipment suitable for use with fire alarm systems as defined by Figure 1 of EN 54-1:1996 Fire detection and fire alarm systems Part 1. Alarm transmission equipment suitable for use with intruder alarm and hold-up systems is listed in Part 6:Section 1.2 of the Red Book. Where alarm transmission equipment may be suitable for use with both fire alarm systems and intruder alarm and hold-up systems the entry for the approved equipment will appear in Part 3 and Part 6 of the Red Book. Where appropriate, reference is made to published standards and the following standards are currently used for the approval schemes: EN 54-21:2006 Fire detection and fire alarm systems - Part 21: Alarm transmission and fault warning routing equipment LPS 1277 Requirements for LPCB Approval and listing of Alarm Transmission Systems and Equipment
EN 54-21:2006 is a harmonised standard for the Construction Products Directive and CE marking will be required for most of the European market by May 2009. ANNEX ZA of EN 54-21 states that for CE marking purposes it is not necessary to test the alarm transmission and fault routing equipment performance characteristics in conjunction with the transmission networks to confirm the claimed transmission parameters D, M, T, A ,S and I. These parameters are however described in the EN 54-21 normative ANNEX A and may be tested as an option. Unless otherwise stated LPCB approval to EN 54-21 confirms that the routing equipment meets only those requirements of ANNEX ZA relating to the operational and environmental reliability of the item(s) located within the protected premises. Whereas LPS 1277 includes criteria for both fire and security systems that specifically requires the alarm transmission and fault routing equipment to be tested in conjunction with the appropriate transmission networks. Particular emphasis is placed on the verification of manufacturers claims by measuring alarm transmission times over the transmission path(s) between the equipment under test and the corresponding alarm receiving centre. The response to the reporting of fault conditions is measured in a similar way. The results of these measurements are expressed in terms of alarm transmission system (ATS) performance criteria classification, using the parameters D, M, T and where applicable S and I. Where, D = Transmission time classification M = Transmission time maximum values T = Reporting time classification S = Substitution Security ( LPS category A only) I = Information Security ( LPS category A only) Availability is considered a key parameter under LPCB approval and is therefore included within the requirements of LPS 1277 and the resultant performance is expressed using the parameter A for Availability. The measured values associated with each performance criteria classification are used to determine the category of the alarm transmission equipment. Two categories of alarm transmission equipment are defined in LPS 1277; Category A: Components and associated networks meeting system Category A requirements are suitable for use in fire protection applications classified as being very high risk, i.e. where arson attempts are expected or where fire is expected to spread very rapidly. Category B: Components and associated networks meeting system Category B requirements are suitable for all other fire protection applications.
264
January 2009
ALARM TRANSMISSION AND FAULT MONITORING EQUIPMENT AND SIGNALLING SYSTEMS Products approved to LPS 1277 encompass all of the requirements of EN 54-21 and products tested and approved by the LPCB will have automatically met the compliance criteria of EN 54-21 in full. It is therefore recommended that alarm transmission and fault routing equipment be approved to LPS 1277 where possible. Compliance with relevant safety standards and applicable mandatory directives is a pre-requisite of LPCB approval and listing. Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Notes: Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.
January 2009
265
266
January 2009
Alarm transmission equipment approved to LPS 1277 Requirements for LPCB Approval and listing of Alarm Transmission Systems and Equipment Requirements and tests are included in the Loss Prevention Standard that enables the assessment of the performance of those components of the alarm transmission system normally located in the protected premises when used in conjunction with the appropriate transmission networks.
BT redcare
Monument TE, 11-13 Great Tower Street, London EC3R 5EA UK Tel: +44 (0) 800 800 828 Fax: +44 (0)20 7929 6490 Website: www.redcare.bt.com
Certificate No: 775a to LPS 1277: Issue 2.2 Product Name UC-372G-UK ASSURE STAR Fire Category B Security Grade 3 Primary Transmission Path Asynchronous digital subscriber line (ASDL) operated by BT Broadband Secondary Transmission Path General packet radio service (GRPS) on a BT mobile network LPCB Ref. No. 775a/01
Performance Parameters Transmission Transmission Path Time Classification Primary D4 Secondary Combined
1
Substitution Security S2 S2 S2
Information Security I3 I3 I3
Network Availability5 A3 A1 A3
D4 D4
Approved Ancillaries AO100 External base antenna (short) BA900-5 High gain antenna (long) CAB0106 10m low loss extension cable UltraCapture8 Video Card UltraCapture4 Video Card Notes: 1) The combined performance parameters are shown for the ASSURE STAR as a whole, i.e. with both primary and secondary transmission paths operational. The alarm transmission performance parameters of the ASSURE STAR are consistent with those of ATS 5. 2) During a planned maintenance procedure the ASSURE STAR will achieve performance classification D4 at a maximum transmission time classification M2. The maintenance procedure will be operated approximately four times per year and will be of approximately 5 minutes duration. 3) The loss of the secondary path following a previous failure of the primary path results in a reporting time classification of T4. 4) The simultaneous loss of the primary and secondary transmission paths results in a reporting time classification of T5. 5) Network availability classifications have been based on the limited availability data. At the time of the initial evaluation only a limited number of ASSURE STAR alarm transmission equipment were in service and these were subject to interruption due to engineering trials whilst the data was being recorded. The monitoring of network availability continues and the classification will be updated when available. When operating with both transmission paths functioning correctly the combined system availability will meet classification A3.
January 2009
267
Note: Meets the requirements of LPS 1277 for Category B fire alarm transmission equipment. The DualCom Fire has two transmission paths, a primary path signalling over the Packet Data Radio Network operated by Vodafone Ltd., and a secondary path operating over the Public Switched Telephone Network
Alarm transmission system performance parameters Transmission Transmission time Transmission Reporting time Path classification time classification Max. values M3 1 <90s
Network availability
Primary Secondary
D4 D3
T3 2 T5
A4 A4
Notes: 1) Equivalent to M2 of EN 50136-1-1:1998 2) The simultaneous loss of the primary and secondary transmission paths results in a reporting time classification of T3 Approved with the following Ancillaries CS 1050 DualCom 8 Channel Expander CS 1053 DualCom High gain aerial
268
January 2009
SIGNALLING SYSTEMS
In previous editions of the Red Book this section listed alarm signalling systems approved to special requirements developed by LPCB, prior to the publication of LPS 1277 and EN-54-21. The approval of these products has now expired and has been replaced by approval of products to LPS 1277 and EN-54-21. Please refer to Part 3:Section 11.1 'Alarm Transmission and fault routing equipment' for a list of equipment approved to EN 54-21or Part 3:Section 11.2 'Alarm Transmission and fault routing equipment and systems' for a list of equipment approved to LPS 1277.
BT redcare
Monument TE, 11-13 Great Tower Street, London EC3R 5EA UK Tel: +44 (0) 800 800 828 Fax: +44 (0)20 7929 6490 Website: www.redcare.bt.com
Certificate No: 099a Certificated Products 3GSTU-12V 3GSTU-24V LPCB Ref. No. n/a n/a
Note to Specifiers In January 2008 Red Book entries for the BT Redcare 3GSTU-12V and 3GSTU-24V alarm transmission equipment were removed because the scheme against which these products were approved had been superseded by LPS 1277. LPCB assessment of the quality management system associated with production of the 3GSTU-12V and 3GSTU-24V has been maintained and both products, now referred to as 'Classic STU' and 'Fire STU', are currently being evaluated to LPS 1277. Red Book listing will be reinstated once compliance with the requirements of LPS 1277 has been successfully demonstrated.