Pile Capacity Calculation Sheet

Project: BALAI BOMBA DAN PENYELAMAT AU3, AMPANG, SELANGOR

Pile Type: SPUN PILE


Borehole: 1
Building :

Diameter of pile, d 250 mm Circular


Depth of layer, l 1.5 m
Skin resistance area, As 1.18 m2
End bearing area, Ab 0.05 m2
Safety factor - skin resistance, Fs 2
Safety factor - end bearing, Fb 3

Formulae

Skin resistance, Qs k1 x Nav x As


End bearing, Qb k2 x Nb x Ab
Total capacity, Qu Qs + Qb
Allowable capacity, Qall Qs/Fs + Qb/Fb

Coeficient k1 & k2
Type of Soil
k1 k2
Sand 1 2 400
Silt 2 1.67 250
Clay 3 *αCu 200
Rock 4 RQD -

Claculation Sheet

SPT Soil SPT


Depth αCu Qs Qs cum Qb Qu Qall
Nave Type (N)
0.0 0.00 0.00 0 0.00 0.00
1.5 5 1 10 11.78 11.78 196 208.16 71.35
3.0 8 1 6 18.85 30.63 118 148.46 54.59
4.5 7 3 8 34 40.06 70.70 79 149.25 61.53
6.0 9 1 10 21.21 91.90 196 288.28 111.41
7.5 11.5 1 13 27.10 119.00 255 374.29 144.60
9.0 10 3 7 0.00 119.00 69 187.73 82.41
10.5 6 3 5 27 31.81 150.82 49 199.91 91.77
12.0 4.5 1 4 10.60 161.42 79 239.97 106.89
13.5 5.5 3 7 32 37.70 199.12 69 267.86 122.47
15.0 9 3 11 36 42.42 241.54 108 349.55 156.77
16.5 13 3 15 34 40.06 281.60 147 428.88 189.89
18.0 15 3 15 34 40.06 321.66 147 468.94 209.92
19.5 15 1 15 35.35 357.01 295 651.57 276.69
21.0 33.4 2 52 65.65 422.66 589 1011.78 407.70
22.5 45.9 2 40 90.24 512.90 491 1003.83 420.09
24.0 42.5 2 45 83.63 596.52 552 1148.83 482.36
25.5 47.5 4 50 0.00 596.52 491 1087.46 461.91
27.0 50 4 50 0.00 596.52 491 1087.46 461.91
28.5 50 4 50 0.00 596.52 491 1087.46 461.91

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 1 10/17/2022


Cut Fill Ground Water Table Average Bulk Density

0m 6 m 17 kN/m3

β= 0.2

Negative Skin Friction = 0 kN

Qn = b x Pd x As
b = reduction factor Pd = effective overburden pressure (kPa)
b = 0,2 for n-c clay with LL>50%
b = 0,3 for silt and n - c clay of low to normal plasticity
b = 0,35 for sand and gravel
b = 0,4 for rock fill

Thickness of compressible layer = 0 m


Unit weight of soft soil = 17 kN/m3

Minimum Column Load = kN


Maximum Column Load = kN
Allowable Bearing Capacity = kN
Net Bearing Capacity = 0.0 kN `
Estimated Penetration Length = m with loading 350 kN/pile

Direkabentuk Disemak

……………….. ………………..

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 2 10/17/2022


Pile Capacity Calculation Sheet

Project: BALAI BOMBA DAN PENYELAMAT AU3, AMPANG, SELANGOR

Pile Type: SPUN PILE


Borehole: 2
Building :

Diameter of pile, d 250 mm Circular


Depth of layer, l 1.5 m
Skin resistance area, As 1.18 m2
End bearing area, Ab 0.05 m2
Safety factor - skin resistance, Fs 2
Safety factor - end bearing, Fb 3

Formulae

Skin resistance, Qs k1 x Nav x As


End bearing, Qb k2 x Nb x Ab
Total capacity, Qu Qs + Qb
Allowable capacity, Qall Qs/Fs + Qb/Fb

Coeficient k1 & k2
Type of Soil
k1 k2
Sand 1 2 400
Silt 2 1.67 250
Clay 3 *αCu 200
Rock 4 RQD -

Claculation Sheet

SPT Soil SPT


Depth αCu Qs Qs cum Qb Qu Qall
Nave Type (N)
0.0 0.00 0.00 0 0.00 0.00
1.5 3.5 1 7 8.25 8.25 137 145.71 49.94
3.0 6 1 5 14.14 22.39 98 120.57 43.92
4.5 6 1 7 14.14 36.53 137 173.99 64.08
6.0 10.5 1 14 24.74 61.27 275 336.19 122.28
7.5 12.5 1 11 29.46 90.73 216 306.74 117.37
9.0 8.5 3 6 30 35.35 126.07 59 184.99 82.67
10.5 8.5 3 11 36 42.42 168.49 108 276.50 120.25
12.0 9 1 7 21.21 189.70 137 327.16 140.67
13.5 139.9 1 273 176.74 366.44 736 1102.84 428.69
15.0 261.4 1 250 176.74 543.17 736 1279.58 517.06
16.5 125 4 0.00 543.17 0 543.17 271.59
18.0 0 4 0.00 543.17 0 543.17 271.59
19.5 0 4 0.00 543.17 0 543.17 271.59

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 3 10/17/2022


Cut Fill Ground Water Table Average Bulk Density

0m 7.3 m 17 kN/m3

β= 0.2

Negative Skin Friction = 0 kN

Qn = b x Pd x As
b = reduction factor Pd = effective overburden pressure (kPa)
b = 0,2 for n-c clay with LL>50%
b = 0,3 for silt and n - c clay of low to normal plasticity
b = 0,35 for sand and gravel
b = 0,4 for rock fill

Thickness of compressible layer = 0 m


Unit weight of soft soil = 17 kN/m3

Minimum Column Load = kN


Maximum Column Load = kN
Allowable Bearing Capacity = kN
Net Bearing Capacity = 0.0 kN `
Estimated Penetration Length = m with loading 350 kN/pile

Direkabentuk Disemak

……………….. ………………..

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 4 10/17/2022


Pile Capacity Calculation Sheet

Project: BALAI BOMBA DAN PENYELAMAT AU3, AMPANG, SELANGOR

Pile Type: SPUN PILE


Borehole: 3
Building :

Diameter of pile, d 250 mm Circular


Depth of layer, l 1.5 m
Skin resistance area, As 1.18 m2
End bearing area, Ab 0.05 m2
Safety factor - skin resistance, Fs 2
Safety factor - end bearing, Fb 3

Formulae

Skin resistance, Qs k1 x Nav x As


End bearing, Qb k2 x Nb x Ab
Total capacity, Qu Qs + Qb
Allowable capacity, Qall Qs/Fs + Qb/Fb

Coeficient k1 & k2
Type of Soil
k1 k2
Sand 1 2 400
Silt 2 1.67 250
Clay 3 *αCu 200
Rock 4 RQD -

Claculation Sheet

SPT Soil SPT


Depth αCu Qs Qs cum Qb Qu Qall
Nave Type (N)
0.0 0.00 0.00 0 0.00 0.00
1.5 4 1 8 9.43 9.43 157 166.53 57.08
3.0 15.5 1 23 36.53 45.95 452 497.61 173.53
4.5 12.5 3 2 12 14.14 60.09 20 79.73 36.59
6.0 13 3 24 38 44.77 104.86 236 340.51 130.98
7.5 16.5 1 9 38.88 143.75 177 320.48 130.79
9.0 10 1 11 23.57 167.31 216 383.32 155.66
10.5 8.5 3 6 30 35.35 202.66 59 261.57 120.97
12.0 11 2 16 21.64 224.30 196 420.68 177.61
13.5 16.5 1 17 38.88 263.19 334 597.02 242.87
15.0 24 2 31 47.22 310.41 380 690.89 282.03
16.5 33.5 1 36 78.94 389.35 707 1096.30 430.33
18.0 44.8 1 54 105.54 494.89 736 1231.30 492.91
19.5 26.8 4 0.00 494.89 0 494.89 247.45
21.0 0.0 4 0.00 494.89 0 494.89 247.45
22.5 0.0 4 0.00 494.89 0 494.89 247.45

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 5 10/17/2022


Cut Fill Ground Water Table Average Bulk Density

0m 3.2 m 17 kN/m3

β= 0.2

Negative Skin Friction = 0 kN

Qn = b x Pd x As
b = reduction factor Pd = effective overburden pressure (kPa)
b = 0,2 for n-c clay with LL>50%
b = 0,3 for silt and n - c clay of low to normal plasticity
b = 0,35 for sand and gravel
b = 0,4 for rock fill

Thickness of compressible layer = 0 m


Unit weight of soft soil = 17 kN/m3

Minimum Column Load = kN


Maximum Column Load = kN
Allowable Bearing Capacity = kN
Net Bearing Capacity = 0.0 kN `
Estimated Penetration Length = m with loading 350 kN/pile

Direkabentuk Disemak

……………….. ………………..

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 6 10/17/2022


Pile Capacity Calculation Sheet

Project: BALAI BOMBA DAN PENYELAMAT AU3, AMPANG, SELANGOR

Pile Type: SPUN PILE


Borehole: 4
Building :

Diameter of pile, d 250 mm Circular


Depth of layer, l 1.5 m
Skin resistance area, As 1.18 m2
End bearing area, Ab 0.05 m2
Safety factor - skin resistance, Fs 2
Safety factor - end bearing, Fb 3

Formulae

Skin resistance, Qs k1 x Nav x As


End bearing, Qb k2 x Nb x Ab
Total capacity, Qu Qs + Qb
Allowable capacity, Qall Qs/Fs + Qb/Fb

Coeficient k1 & k2
Type of Soil
k1 k2
Sand 1 2 400
Silt 2 1.67 250
Clay 3 *αCu 200
Rock 4 RQD -

Claculation Sheet

SPT Soil SPT


Depth αCu Qs Qs cum Qb Qu Qall
Nave Type (N)
0.0 0.00 0.00 0 0.00 0.00
1.5 3.5 1 7 8.25 8.25 137 145.71 49.94
3.0 6 1 5 14.14 22.39 98 120.57 43.92
4.5 5 1 5 11.78 34.17 98 132.36 49.81
6.0 7.5 1 10 17.67 51.84 196 248.22 91.38
7.5 9 1 8 21.21 73.05 157 230.15 88.89
9.0 11 1 14 25.92 98.97 275 373.90 141.13
10.5 13.5 1 13 31.81 130.79 255 386.07 150.49
12.0 9.5 3 6 30 35.35 166.13 59 225.05 102.70
13.5 5.5 3 5 27 31.81 197.95 49 247.04 115.34
15.0 117.9 1 231 176.74 374.68 736 1111.09 432.81
16.5 115.4 4 0.00 374.68 0 374.68 187.34
18.0 0 4 0.00 374.68 0 374.68 187.34
19.5 0 4 0.00 374.68 0 374.68 187.34

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 7 10/17/2022


Cut Fill Ground Water Table Average Bulk Density

0m 2.3 m 17 kN/m3

β= 0.2

Negative Skin Friction = 0 kN

Qn = b x Pd x As
b = reduction factor Pd = effective overburden pressure (kPa)
b = 0,2 for n-c clay with LL>50%
b = 0,3 for silt and n - c clay of low to normal plasticity
b = 0,35 for sand and gravel
b = 0,4 for rock fill

Thickness of compressible layer = 0 m


Unit weight of soft soil = 17 kN/m3

Minimum Column Load = kN


Maximum Column Load = kN
Allowable Bearing Capacity = kN
Net Bearing Capacity = 0.0 kN `
Estimated Penetration Length = m with loading 350 kN/pile

Direkabentuk Disemak

……………….. ………………..

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 8 10/17/2022


Pile Capacity Calculation Sheet

Project: BALAI BOMBA DAN PENYELAMAT AU3, AMPANG, SELANGOR

Pile Type: SPUN PILE


Borehole: 5
Building :

Diameter of pile, d 250 mm Circular


Depth of layer, l 1.5 m
Skin resistance area, As 1.18 m2
End bearing area, Ab 0.05 m2
Safety factor - skin resistance, Fs 2
Safety factor - end bearing, Fb 3

Formulae

Skin resistance, Qs k1 x Nav x As


End bearing, Qb k2 x Nb x Ab
Total capacity, Qu Qs + Qb
Allowable capacity, Qall Qs/Fs + Qb/Fb

Coeficient k1 & k2
Type of Soil
k1 k2
Sand 1 2 400
Silt 2 1.67 250
Clay 3 *αCu 200
Rock 4 RQD -

Claculation Sheet

SPT Soil SPT


Depth αCu Qs Qs cum Qb Qu Qall
Nave Type (N)
0.0 0.00 0.00 0 0.00 0.00
1.5 2.5 3 5 27 31.81 31.81 49 80.91 32.27
3.0 12.5 1 20 29.46 61.27 393 454.02 161.55
4.5 13 1 6 30.63 91.90 118 209.73 85.23
6.0 6 3 6 30 35.35 127.25 59 186.16 83.26
7.5 6 3 6 30 35.35 162.60 59 221.51 100.94
9.0 6.5 1 7 15.32 177.92 137 315.38 134.78
10.5 7.5 3 8 34 40.06 217.98 79 296.53 135.17
12.0 9.5 1 11 22.39 240.36 216 456.38 192.19
13.5 8 3 5 27 31.81 272.18 49 321.27 152.45
15.0 7 3 9 35 41.24 313.41 88 401.78 186.16
16.5 51.4 1 94 121.07 434.48 736 1170.89 462.71
18.0 46.9 4 0.00 434.48 0 434.48 217.24
19.5 0 4 0.00 434.48 0 434.48 217.24
21.0 0.0 4 0.00 434.48 0 434.48 217.24

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 9 10/17/2022


Cut Fill Ground Water Table Average Bulk Density

0m 2.2 m 17 kN/m3

β= 0.2

Negative Skin Friction = 0 kN

Qn = b x Pd x As
b = reduction factor Pd = effective overburden pressure (kPa)
b = 0,2 for n-c clay with LL>50%
b = 0,3 for silt and n - c clay of low to normal plasticity
b = 0,35 for sand and gravel
b = 0,4 for rock fill

Thickness of compressible layer = 0 m


Unit weight of soft soil = 17 kN/m3

Minimum Column Load = kN


Maximum Column Load = kN
Allowable Bearing Capacity = kN
Net Bearing Capacity = 0.0 kN `
Estimated Penetration Length = m with loading 350 kN/pile

Direkabentuk Disemak

……………….. ………………..

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 10 10/17/2022


Pile Capacity Calculation Sheet

Project: BALAI BOMBA DAN PENYELAMAT AU3, AMPANG, SELANGOR

Pile Type: SPUN PILE


Borehole: 3
Building : BALAI BOMBA

Diameter of pile, d 250 mm Circular


Depth of layer, l 1.5 m
Skin resistance area, As 1.18 m2
End bearing area, Ab 0.05 m2
Safety factor - skin resistance, Fs 2
Safety factor - end bearing, Fb 3

Formulae

Skin resistance, Qs k1 x Nav x As


End bearing, Qb k2 x Nb x Ab
Total capacity, Qu Qs + Qb
Allowable capacity, Qall Qs/Fs + Qb/Fb

Coeficient k1 & k2
Type of Soil
k1 k2
Sand 1 2 400
Silt 2 1.67 250
Clay 3 *αCu 200
Rock 4 RQD -

Claculation Sheet

SPT Soil SPT


Depth αCu Qs Qs cum Qb Qu Qall
Nave Type (N)
0.0 0.00 0.00 0 0.00 0.00
1.5 4 1 8 9.43 9.43 157 166.53 57.08
3.0 15.5 1 23 36.53 45.95 452 497.61 173.53
4.5 12.5 3 2 12 14.14 60.09 20 79.73 36.59
6.0 13 3 24 38 44.77 104.86 236 340.51 130.98
7.5 16.5 1 9 38.88 143.75 177 320.48 130.79
9.0 10 1 11 23.57 167.31 216 383.32 155.66
10.5 8.5 3 6 30 35.35 202.66 59 261.57 120.97
12.0 11 2 16 21.64 224.30 196 420.68 177.61
13.5 16.5 1 17 38.88 263.19 334 597.02 242.87
15.0 24 2 31 47.22 310.41 380 690.89 282.03
16.5 33.5 1 36 78.94 389.35 707 1096.30 430.33
18.0 44.8 1 54 105.54 494.89 736 1231.30 492.91
19.5 26.8 4 0.00 494.89 0 494.89 247.45
21.0 0.0 4 0.00 494.89 0 494.89 247.45
22.5 0.0 4 0.00 494.89 0 494.89 247.45

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 11 10/17/2022


Cut ✘ Fill Ground Water Table Average Bulk Density

1.1 m 3.2 m 17 kN/m3

β= 0.2

Negative Skin Friction = 2.9378 kN

Qn = b x Pd x As
b = reduction factor Pd = effective overburden pressure (kPa)
b = 0,2 for n-c clay with LL>50%
b = 0,3 for silt and n - c clay of low to normal plasticity
b = 0,35 for sand and gravel
b = 0,4 for rock fill

Thickness of compressible layer = 0 m


Unit weight of soft soil = 17 kN/m3

Minimum Column Load = 110 kN


Maximum Column Load = 1000 kN
Allowable Bearing Capacity = 430.3 kN
Net Bearing Capacity = 427.4 kN `
Estimated Penetration Length = 17.6 m with loading 350 kN/pile

Direkabentuk Disemak

……………….. ………………..

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 12 10/17/2022


Pile Capacity Calculation Sheet

Project: BALAI BOMBA DAN PENYELAMAT AU3, AMPANG, SELANGOR

Pile Type: SPUN PILE


Borehole: 1
Building : MENARA LATIHAN

Diameter of pile, d 250 mm Circular


Depth of layer, l 1.5 m
Skin resistance area, As 1.18 m2
End bearing area, Ab 0.05 m2
Safety factor - skin resistance, Fs 2
Safety factor - end bearing, Fb 3

Formulae

Skin resistance, Qs k1 x Nav x As


End bearing, Qb k2 x Nb x Ab
Total capacity, Qu Qs + Qb
Allowable capacity, Qall Qs/Fs + Qb/Fb

Coeficient k1 & k2
Type of Soil
k1 k2
Sand 1 2 400
Silt 2 1.67 250
Clay 3 *αCu 200
Rock 4 RQD -

Claculation Sheet

SPT Soil SPT


Depth αCu Qs Qs cum Qb Qu Qall
Nave Type (N)
0.0 0.00 0.00 0 0.00 0.00
1.5 5 1 10 11.78 11.78 196 208.16 71.35
3.0 8 1 6 18.85 30.63 118 148.46 54.59
4.5 7 3 8 34 40.06 70.70 79 149.25 61.53
6.0 9 1 10 21.21 91.90 196 288.28 111.41
7.5 11.5 1 13 27.10 119.00 255 374.29 144.60
9.0 10 3 7 0.00 119.00 69 187.73 82.41
10.5 6 3 5 27 31.81 150.82 49 199.91 91.77
12.0 4.5 1 4 10.60 161.42 79 239.97 106.89
13.5 5.5 3 7 32 37.70 199.12 69 267.86 122.47
15.0 9 3 11 36 42.42 241.54 108 349.55 156.77
16.5 13 3 15 34 40.06 281.60 147 428.88 189.89
18.0 15 3 15 34 40.06 321.66 147 468.94 209.92
19.5 15 1 15 35.35 357.01 295 651.57 276.69
21.0 33.4 2 52 65.65 422.66 589 1011.78 407.70
22.5 45.9 2 40 90.24 512.90 491 1003.83 420.09
24.0 42.5 2 45 83.63 596.52 552 1148.83 482.36
25.5 47.5 4 50 0.00 596.52 491 1087.46 461.91
27.0 50 4 50 0.00 596.52 491 1087.46 461.91
28.5 50 4 50 0.00 596.52 491 1087.46 461.91

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 13 10/17/2022


✘ Cut Fill Ground Water Table Average Bulk Density

3.14 m 6 m 17 kN/m3

β= 0.2

Negative Skin Friction = 8.386 kN

Qn = b x Pd x As
b = reduction factor Pd = effective overburden pressure (kPa)
b = 0,2 for n-c clay with LL>50%
b = 0,3 for silt and n - c clay of low to normal plasticity
b = 0,35 for sand and gravel
b = 0,4 for rock fill

Thickness of compressible layer = 0 m


Unit weight of soft soil = 17 kN/m3

Minimum Column Load = 60 kN


Maximum Column Load = 1290 kN
Allowable Bearing Capacity = 407.7 kN
Net Bearing Capacity = 399.3 kN `
Estimated Penetration Length = 17.9 m with loading 350 kN/pile

Direkabentuk Disemak

……………….. ………………..

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 14 10/17/2022


Pile Capacity Calculation Sheet

Project: BALAI BOMBA DAN PENYELAMAT AU3, AMPANG, SELANGOR

Pile Type: SPUN PILE


Borehole: 3
Building : STOR BASAH & KERING

Diameter of pile, d 250 mm Circular


Depth of layer, l 1.5 m
Skin resistance area, As 1.18 m2
End bearing area, Ab 0.05 m2
Safety factor - skin resistance, Fs 2
Safety factor - end bearing, Fb 3

Formulae

Skin resistance, Qs k1 x Nav x As


End bearing, Qb k2 x Nb x Ab
Total capacity, Qu Qs + Qb
Allowable capacity, Qall Qs/Fs + Qb/Fb

Coeficient k1 & k2
Type of Soil
k1 k2
Sand 1 2 400
Silt 2 1.67 250
Clay 3 *αCu 200
Rock 4 RQD -

Claculation Sheet

SPT Soil SPT


Depth αCu Qs Qs cum Qb Qu Qall
Nave Type (N)
0.0 0.00 0.00 0 0.00 0.00
1.5 4 1 8 9.43 9.43 157 166.53 57.08
3.0 15.5 1 23 36.53 45.95 452 497.61 173.53
4.5 12.5 3 2 12 14.14 60.09 20 79.73 36.59
6.0 13 3 24 38 44.77 104.86 236 340.51 130.98
7.5 16.5 1 9 38.88 143.75 177 320.48 130.79
9.0 10 1 11 23.57 167.31 216 383.32 155.66
10.5 8.5 3 6 30 35.35 202.66 59 261.57 120.97
12.0 11 2 16 21.64 224.30 196 420.68 177.61
13.5 16.5 1 17 38.88 263.19 334 597.02 242.87
15.0 24 2 31 47.22 310.41 380 690.89 282.03
16.5 33.5 1 36 78.94 389.35 707 1096.30 430.33
18.0 44.8 1 54 105.54 494.89 736 1231.30 492.91
19.5 26.8 4 0.00 494.89 0 494.89 247.45
21.0 0.0 4 0.00 494.89 0 494.89 247.45
22.5 0.0 4 0.00 494.89 0 494.89 247.45

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 15 10/17/2022


Cut ✘ Fill Ground Water Table Average Bulk Density

1.44 m 3.2 m 17 kN/m3

β= 0.2

Negative Skin Friction = 3.8458 kN

Qn = b x Pd x As
b = reduction factor Pd = effective overburden pressure (kPa)
b = 0,2 for n-c clay with LL>50%
b = 0,3 for silt and n - c clay of low to normal plasticity
b = 0,35 for sand and gravel
b = 0,4 for rock fill

Thickness of compressible layer = 0 m


Unit weight of soft soil = 17 kN/m3

Minimum Column Load = 180 kN


Maximum Column Load = 325 kN
Allowable Bearing Capacity = 282.0 kN
Net Bearing Capacity = 278.2 kN `
Estimated Penetration Length = 16.4 m with loading 250 kN/pile

Direkabentuk Disemak

……………….. ………………..

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 16 10/17/2022


Pile Capacity Calculation Sheet

Project: BALAI BOMBA DAN PENYELAMAT AU3, AMPANG, SELANGOR

Pile Type: SPUN PILE


Borehole: 5
Building : STOR BASAH & KERING

Diameter of pile, d 250 mm Circular


Depth of layer, l 1.5 m
Skin resistance area, As 1.18 m2
End bearing area, Ab 0.05 m2
Safety factor - skin resistance, Fs 2
Safety factor - end bearing, Fb 3

Formulae

Skin resistance, Qs k1 x Nav x As


End bearing, Qb k2 x Nb x Ab
Total capacity, Qu Qs + Qb
Allowable capacity, Qall Qs/Fs + Qb/Fb

Coeficient k1 & k2
Type of Soil
k1 k2
Sand 1 2 400
Silt 2 1.67 250
Clay 3 *αCu 200
Rock 4 RQD -

Claculation Sheet

SPT Soil SPT


Depth αCu Qs Qs cum Qb Qu Qall
Nave Type (N)
0.0 0.00 0.00 0 0.00 0.00
1.5 2.5 3 5 27 31.81 31.81 49 80.91 32.27
3.0 12.5 1 20 29.46 61.27 393 454.02 161.55
4.5 13 1 6 30.63 91.90 118 209.73 85.23
6.0 6 3 6 30 35.35 127.25 59 186.16 83.26
7.5 6 3 6 30 35.35 162.60 59 221.51 100.94
9.0 6.5 1 7 15.32 177.92 137 315.38 134.78
10.5 7.5 3 8 34 40.06 217.98 79 296.53 135.17
12.0 9.5 1 11 22.39 240.36 216 456.38 192.19
13.5 8 3 5 27 31.81 272.18 49 321.27 152.45
15.0 7 3 9 35 41.24 313.41 88 401.78 186.16
16.5 51.4 1 94 121.07 434.48 736 1170.89 462.71
18.0 46.9 4 0.00 434.48 0 434.48 217.24
19.5 0 4 0.00 434.48 0 434.48 217.24
21.0 0.0 4 0.00 434.48 0 434.48 217.24

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 17 10/17/2022


Cut ✘ Fill Ground Water Table Average Bulk Density

1.44 m 2.2 m 17 kN/m3

β= 0.2

Negative Skin Friction = 3.8458 kN

Qn = b x Pd x As
b = reduction factor Pd = effective overburden pressure (kPa)
b = 0,2 for n-c clay with LL>50%
b = 0,3 for silt and n - c clay of low to normal plasticity
b = 0,35 for sand and gravel
b = 0,4 for rock fill

Thickness of compressible layer = 0 m


Unit weight of soft soil = 17 kN/m3

Minimum Column Load = 180 kN


Maximum Column Load = 325 kN
Allowable Bearing Capacity = 462.7 kN
Net Bearing Capacity = 458.9 kN `
Estimated Penetration Length = 17.9 m with loading 250 kN/pile

Direkabentuk Disemak

……………….. ………………..

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 18 10/17/2022


Pile Capacity Calculation Sheet

Project: BALAI BOMBA DAN PENYELAMAT AU3, AMPANG, SELANGOR

Pile Type: SPUN PILE


Borehole: 3
Building : RUMAH PAM DAN TANGKI SEDUT

Diameter of pile, d 250 mm Circular


Depth of layer, l 1.5 m
Skin resistance area, As 1.18 m2
End bearing area, Ab 0.05 m2
Safety factor - skin resistance, Fs 2
Safety factor - end bearing, Fb 3

Formulae

Skin resistance, Qs k1 x Nav x As


End bearing, Qb k2 x Nb x Ab
Total capacity, Qu Qs + Qb
Allowable capacity, Qall Qs/Fs + Qb/Fb

Coeficient k1 & k2
Type of Soil
k1 k2
Sand 1 2 400
Silt 2 1.67 250
Clay 3 *αCu 200
Rock 4 RQD -

Claculation Sheet

SPT Soil SPT


Depth αCu Qs Qs cum Qb Qu Qall
Nave Type (N)
0.0 0.00 0.00 0 0.00 0.00
1.5 4 1 8 9.43 9.43 157 166.53 57.08
3.0 15.5 1 23 36.53 45.95 452 497.61 173.53
4.5 12.5 3 2 12 14.14 60.09 20 79.73 36.59
6.0 13 3 24 38 44.77 104.86 236 340.51 130.98
7.5 16.5 1 9 38.88 143.75 177 320.48 130.79
9.0 10 1 11 23.57 167.31 216 383.32 155.66
10.5 8.5 3 6 30 35.35 202.66 59 261.57 120.97
12.0 11 2 16 21.64 224.30 196 420.68 177.61
13.5 16.5 1 17 38.88 263.19 334 597.02 242.87
15.0 24 2 31 47.22 310.41 380 690.89 282.03
16.5 33.5 1 36 78.94 389.35 707 1096.30 430.33
18.0 44.8 1 54 105.54 494.89 736 1231.30 492.91
19.5 26.8 4 0.00 494.89 0 494.89 247.45
21.0 0.0 4 0.00 494.89 0 494.89 247.45
22.5 0.0 4 0.00 494.89 0 494.89 247.45

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 19 10/17/2022


Cut ✘ Fill Ground Water Table Average Bulk Density

0.8 m 3.2 m 17 kN/m3

β= 0.2

Negative Skin Friction = 2.1366 kN

Qn = b x Pd x As
b = reduction factor Pd = effective overburden pressure (kPa)
b = 0,2 for n-c clay with LL>50%
b = 0,3 for silt and n - c clay of low to normal plasticity
b = 0,35 for sand and gravel
b = 0,4 for rock fill

Thickness of compressible layer = 0 m


Unit weight of soft soil = 17 kN/m3

Minimum Column Load = 180 kN


Maximum Column Load = 325 kN
Allowable Bearing Capacity = 282.0 kN
Net Bearing Capacity = 279.9 kN `
Estimated Penetration Length = 15.8 m with loading 250 kN/pile

Direkabentuk Disemak

……………….. ………………..

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 20 10/17/2022


Pile Capacity Calculation Sheet

Project: BALAI BOMBA DAN PENYELAMAT AU3, AMPANG, SELANGOR

Pile Type: SPUN PILE


Borehole: 5
Building : RUMAH PAM DAN TANGKI SEDUT

Diameter of pile, d 250 mm Circular


Depth of layer, l 1.5 m
Skin resistance area, As 1.18 m2
End bearing area, Ab 0.05 m2
Safety factor - skin resistance, Fs 2
Safety factor - end bearing, Fb 3

Formulae

Skin resistance, Qs k1 x Nav x As


End bearing, Qb k2 x Nb x Ab
Total capacity, Qu Qs + Qb
Allowable capacity, Qall Qs/Fs + Qb/Fb

Coeficient k1 & k2
Type of Soil
k1 k2
Sand 1 2 400
Silt 2 1.67 250
Clay 3 *αCu 200
Rock 4 RQD -

Claculation Sheet

SPT Soil SPT


Depth αCu Qs Qs cum Qb Qu Qall
Nave Type (N)
0.0 0.00 0.00 0 0.00 0.00
1.5 2.5 3 5 27 31.81 31.81 49 80.91 32.27
3.0 12.5 1 20 29.46 61.27 393 454.02 161.55
4.5 13 1 6 30.63 91.90 118 209.73 85.23
6.0 6 3 6 30 35.35 127.25 59 186.16 83.26
7.5 6 3 6 30 35.35 162.60 59 221.51 100.94
9.0 6.5 1 7 15.32 177.92 137 315.38 134.78
10.5 7.5 3 8 34 40.06 217.98 79 296.53 135.17
12.0 9.5 1 11 22.39 240.36 216 456.38 192.19
13.5 8 3 5 27 31.81 272.18 49 321.27 152.45
15.0 7 3 9 35 41.24 313.41 88 401.78 186.16
16.5 51.4 1 94 121.07 434.48 736 1170.89 462.71
18.0 46.9 4 0.00 434.48 0 434.48 217.24
19.5 0 4 0.00 434.48 0 434.48 217.24
21.0 0.0 4 0.00 434.48 0 434.48 217.24

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 21 10/17/2022


Cut ✘ Fill Ground Water Table Average Bulk Density

0.8 m 2.2 m 17 kN/m3

β= 0.2

Negative Skin Friction = 2.1366 kN

Qn = b x Pd x As
b = reduction factor Pd = effective overburden pressure (kPa)
b = 0,2 for n-c clay with LL>50%
b = 0,3 for silt and n - c clay of low to normal plasticity
b = 0,35 for sand and gravel
b = 0,4 for rock fill

Thickness of compressible layer = 0 m


Unit weight of soft soil = 17 kN/m3

Minimum Column Load = 180 kN


Maximum Column Load = 325 kN
Allowable Bearing Capacity = 462.7 kN
Net Bearing Capacity = 460.6 kN `
Estimated Penetration Length = 17.3 m with loading 250 kN/pile

Direkabentuk Disemak

……………….. ………………..

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 22 10/17/2022


Pile Capacity Calculation Sheet

Project: BALAI BOMBA DAN PENYELAMAT AU3, AMPANG, SELANGOR

Pile Type: SPUN PILE


Borehole: 3
Building : PENCAWANG TNB

Diameter of pile, d 250 mm Circular


Depth of layer, l 1.5 m
Skin resistance area, As 1.18 m2
End bearing area, Ab 0.05 m2
Safety factor - skin resistance, Fs 2
Safety factor - end bearing, Fb 3

Formulae

Skin resistance, Qs k1 x Nav x As


End bearing, Qb k2 x Nb x Ab
Total capacity, Qu Qs + Qb
Allowable capacity, Qall Qs/Fs + Qb/Fb

Coeficient k1 & k2
Type of Soil
k1 k2
Sand 1 2 400
Silt 2 1.67 250
Clay 3 *αCu 200
Rock 4 RQD -

Claculation Sheet

SPT Soil SPT


Depth αCu Qs Qs cum Qb Qu Qall
Nave Type (N)
0.0 0.00 0.00 0 0.00 0.00
1.5 4 1 8 9.43 9.43 157 166.53 57.08
3.0 15.5 1 23 36.53 45.95 452 497.61 173.53
4.5 12.5 3 2 12 14.14 60.09 20 79.73 36.59
6.0 13 3 24 38 44.77 104.86 236 340.51 130.98
7.5 16.5 1 9 38.88 143.75 177 320.48 130.79
9.0 10 1 11 23.57 167.31 216 383.32 155.66
10.5 8.5 3 6 30 35.35 202.66 59 261.57 120.97
12.0 11 2 16 21.64 224.30 196 420.68 177.61
13.5 16.5 1 17 38.88 263.19 334 597.02 242.87
15.0 24 2 31 47.22 310.41 380 690.89 282.03
16.5 33.5 1 36 78.94 389.35 707 1096.30 430.33
18.0 44.8 1 54 105.54 494.89 736 1231.30 492.91
19.5 26.8 4 0.00 494.89 0 494.89 247.45
21.0 0.0 4 0.00 494.89 0 494.89 247.45
22.5 0.0 4 0.00 494.89 0 494.89 247.45

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 23 10/17/2022


Cut ✘ Fill Ground Water Table Average Bulk Density

0.8 m 3.2 m 17 kN/m3

β= 0.2

Negative Skin Friction = 2.1366 kN

Qn = b x Pd x As
b = reduction factor Pd = effective overburden pressure (kPa)
b = 0,2 for n-c clay with LL>50%
b = 0,3 for silt and n - c clay of low to normal plasticity
b = 0,35 for sand and gravel
b = 0,4 for rock fill

Thickness of compressible layer = 0 m


Unit weight of soft soil = 17 kN/m3

Minimum Column Load = 160 kN


Maximum Column Load = 290 kN
Allowable Bearing Capacity = 282.0 kN
Net Bearing Capacity = 279.9 kN `
Estimated Penetration Length = 15.8 m with loading 250 kN/pile

Direkabentuk Disemak

……………….. ………………..

By JKR Cawangan Kejuruteraan Jalan dan Geoteknik 24 10/17/2022