Sun® 45L Automatic Large Autoclave Steam Sterilizer Machine Class B with Printer

Spec of sterilizing:

1. It adopts European class B standard.

It can sterilze all kinds of medical insruments and solved the difficult problem

of plastic instruments sterilized.

2. Computer-controlled, the pressure and the temperature digitization displayed, makes you

operation more easy and convenient.

3. Jet steam generator, makes the temperature of the chamber stable and the steam reaches

every corner.

4. The chamber is once stretch forming of 2.5mm stainless steel

5. Full water alarm system of waste water tank, Finished has let the waste water circulation

disinfection the possibility, causes the disinfection to have the significance;

6. Automatic failure detections warning, enable you to grasp the loom as necessary dynamically;

7. Humanity bottom of the opt freeing port designs can dryly cause to be more convenient;

8. Entire simulated self-made contours, Let the autoclave be brighter, Has the attraction.
 

Quality Guarantee 
 
1 year warranty for our machine. 
 
Spare parts free on condition that there is non‐human causes. 

 
 

Features:

1.Intelligent operating interface;

Intelligent,one-stop interface;and make the process of operation and sterilization clear at a glance.
2.Intelligent water cooling system 
 
The high temperature pipe made by metal,reliable and durable. 

3. Automatic door lock system 
 
It is easy to operate and completely eliminate the potential danger caused by improper operating of manual door 
closing. 

 
Technical parameters:
Frequency rate:50±1Hz
The most powerful:3500VA
Should the product:29L/45L
Class:Class B standard
Rated voltage:AC220V/110V±10%
Sterilization temperature:134℃/121℃
Special sterilization:
Inactivated AIDS (HV) and hepatitis b (HBV) mad cow virus and spore
Drying procedure:
Powerful vacuum drying, instrument residual humidity < 0.2%
Show:LCD display, touch the keys
Test:
Bowie&Dick steam penetration test, helix spiral test, Vacuum Vacuum test
Security:
The relief valve, pneumatic locking, breakdown self check system
Sterilization record:
With printers, and USB interface to record the sterilization process
Water supply system:
Open water tank cleaning disinfection can, with functions of water quality detection and debris filter,
clean water tank volume: 5 l, wastewater tank: 3 l
Water quality detection:
Whether can detect the water quality conform to the requirements of the equipment
Cleaning procedures:
Automatic cleaning internal line and steam generator
Sterilization chamber configuration:Layer: 2 activities tray
SUN45-III:
Power:3500W
Tank Capacity:45Litres
Voltage:AC220V/110V±10%
Frequency:50/60Hz±1Hz
Inside diameter size:Φ319mm X 620mm
Appearance size:845X605X540mm
Outside Dimension:970×730×660mm
Net weight:113kg
Please Note:
1. The autoclave must be plced on the horizontal working base.
2. Must use the distilled water for the purpose of lasting the working life.
3. There shall be no clog to the air cooling window on the outer surface.
4. The object apparatus to be sterilized shall be palced on teh device plate with enough clearnace retained
in favor of the air circulation inside the sterilizing room.
5. Empty the water inside the cooling water collecting tank frequently. Usually, the cooling water
collecting tank shall be emptied once the water storing tank emptied.
6. Must revolve teh door handle to the teminal side while working.
7. Don't open the door of autoclave when seeing the "0" displayed on teh pressure indicator.
8. Not be too closed to the door of the autoclave in case of scald when open the door.
9. Shut off the power before discharging/installing the sealing ring, and the work shall be carried out after
further sufficient cooling in case of scald.
10. Don't drag or drop the autoclave during relocation period of the autoclave.
11. The protecting ground shall be reliable.
12. Equipment must be used away from teh magnetic field.