Brochure Modem HXM 100

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

HXM100

SMART WIRELESS MODEM


GSM/GPRS/3G
HXM100 is a wireless modem that allows users to connect to a GSM/GPRS and 3G
network, used as a communication media for two way communication system such as
Automatic Meter Reading (AMR).

 Highlights
1. Support 3G and 2G network, or only 2G network
2. UMTS, GSM/GPRS,CSD,USSD and SMS server
3. Easy to set for application by pc software and SMS
4. Open AT command set based on GSM 07.05 & 07.07
5. Embedded TCP/IP and UDP/IP protocol stack
6. Double color LED to indicate different work states
7. Security protection by username and password

 Features
2G mode: (only) 1.8V/3V SIM interface
900/1800MHz Text & PDU
GPRS Class B with 10 Multi-slot Point to point (MT/MO)
Cell broadcast
3G mode
900/2100MHz RS-232 Interface:
900/1800MHz DB9 female port
GPRS Class B with 33 Multi-slot Standard Serial interface
Baud rate (bits/s): 2400/4800/9600
GPRS Disable/enable DTR/CTS
APN, username, password
IP address, heart Application
IMEI, CCID Transparent and Non Transparent modes
CSQ Use AT Command facility
Can work with different meter types
SMS Can be configured remotely
Others
Can automatic reset by internal timer if needed

 Specifications
Description Value
Voltage
Power supply 90 VAC to 240 VAC
Nominal voltage 12 VDC 1.25A
Operating voltage range 5 VDC to 32 VDC
Temperature
Operation range -25℃ to +65℃
Limit range for storage and transport -25℃ to +85℃
Humidity Up to 90%
Power Consumption
Power consumption during communication ≤4VA
Power consumption during standby mode ≤0.4VA

Transmit power Class 4 (2W):900 MHz,GSM


Class 1 (1W):1800 MHz,GSM
Class 3 (0.25W):2100 MHz,WCDMA

Reception sensitivity
GSM -108dBm(Typical)
3G -109dBm(Typical)

EMC
Electrostatic discharges 6kV
Protection Level IP52
Interface
RS232 interface 24V
Dimension 99.9mm×66mm×26.5mm

 Standard
SPLN D3.023:2013 Modem for controlled remote automatic meter reading(AMR)
SPLN D5.002:2008 Controlled Remote Energy Meter Reading System
Electromagnetic Compatibility (EMC) Part 4-2: Testing and Measurement Techniques –
IEC 61000-4-2:2000
Electrostatic Discharge Immunity Test;
3GPP Release 99 for GSM/GPRS

 Dimension

PT. HEXING TECHNOLOGY Marketing Office


Kawasan Industri Mitra Karawang (KIM) Gedung Wirausaha Lt. 4

Jalan Mitra Timur II Blok D – 24, Karawang – Jawa Barat 41361 Jalan HR. Rasuna Said Kav C – 5, Jakarta Selatan 12940

Telp : (0267) 8610077/89 Fax : (0267) 8610078 Telp : (021) 5200703 Fax : (021) 5200879

You might also like